MIB Viewer

FLOW-METER-MIB

132 objects
MIB for the RTFM Traffic Flow Meter.
Imported Objects
IF-MIBifIndex
RMON2-MIBTimeFilter
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Counter64 Integer32 mib-2 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCRowStatus TEXTUAL-CONVENTION TimeStamp TruthValue
OIDNameAccessStatusDescription
1.3.6.1.2.1.40IdentityflowMIBMIB for the RTFM Traffic Flow Meter.
1.3.6.1.2.1.40.1NodeflowControl
1.3.6.1.2.1.40.1.1TableflowRuleSetInfoTablenot-accessiblecurrentAn array of information about the RuleSets held in the meter. Any manager may configure a new RuleSet for the meter by creating a row in this table with status…
1.3.6.1.2.1.40.1.1.1RowflowRuleSetInfoEntrynot-accessiblecurrentInformation about a particular RuleSet.
1.3.6.1.2.1.40.1.1.1.1ColumnflowRuleInfoIndexnot-accessiblecurrentAn index which selects an entry in the flowRuleSetInfoTable. Each such entry contains control information for a particular RuleSet which the meter may run.
1.3.6.1.2.1.40.1.1.1.2ColumnflowRuleInfoSizeread-createcurrentNumber of rules in this RuleSet. Setting this variable will cause the meter to allocate space for these rules.
1.3.6.1.2.1.40.1.1.1.3ColumnflowRuleInfoOwnerread-createcurrentIdentifies the manager which 'owns' this RuleSet. A manager must set this variable when creating a row in this table.
1.3.6.1.2.1.40.1.1.1.4ColumnflowRuleInfoTimeStampread-onlycurrentTime this row's associated RuleSet was last changed.
1.3.6.1.2.1.40.1.1.1.5ColumnflowRuleInfoStatusread-createcurrentThe status of this flowRuleSetInfoEntry. If this value is not active(1) the meter must not attempt to use the row's associated RuleSet. Once its value has been…
1.3.6.1.2.1.40.1.1.1.6ColumnflowRuleInfoNameread-createcurrentAn alphanumeric identifier used by managers and readers to identify a RuleSet. For example, a manager wishing to run a RuleSet named WWW-FLOWS could search the…
1.3.6.1.2.1.40.1.1.1.7ColumnflowRuleInfoRulesReadyread-createdeprecatedIndicates whether the rules for this row's associated RuleSet are ready for use. The meter will refuse to 'run' the RuleSet unless this variable has been set t…
1.3.6.1.2.1.40.1.1.1.8ColumnflowRuleInfoFlowRecordsread-onlycurrentThe number of entries in the flow table for this RuleSet. These may be current (waiting for collection by one or more meter readers) or idle (waiting for the m…
1.3.6.1.2.1.40.1.2TableflowInterfaceTablenot-accessiblecurrentAn array of information specific to each meter interface.
1.3.6.1.2.1.40.1.2.1RowflowInterfaceEntrynot-accessiblecurrentInformation about a particular interface.
1.3.6.1.2.1.40.1.2.1.1ColumnflowInterfaceSampleRateread-writecurrentThe parameter N for statistical counting on this interface. Set to N to count 1/Nth of the packets appearing at this interface. A sampling rate of 1 counts all…
1.3.6.1.2.1.40.1.2.1.2ColumnflowInterfaceLostPacketsread-onlycurrentThe number of packets the meter has lost for this interface. Such losses may occur because the meter has been unable to keep up with the traffic volume.
1.3.6.1.2.1.40.1.3TableflowReaderInfoTablenot-accessiblecurrentAn array of information about meter readers which have registered their intent to collect flow data from this meter.
1.3.6.1.2.1.40.1.3.1RowflowReaderInfoEntrynot-accessiblecurrentInformation about a particular meter reader.
1.3.6.1.2.1.40.1.3.1.1ColumnflowReaderIndexnot-accessiblecurrentAn index which selects an entry in the flowReaderInfoTable.
1.3.6.1.2.1.40.1.3.1.2ColumnflowReaderTimeoutread-createcurrentSpecifies the maximum time (in seconds) between flow data collections for this meter reader. If this time elapses without a collection, the meter should assume…
1.3.6.1.2.1.40.1.3.1.3ColumnflowReaderOwnerread-createcurrentIdentifies the meter reader which created this row.
1.3.6.1.2.1.40.1.3.1.4ColumnflowReaderLastTimeread-createcurrentTime this meter reader began its most recent data collection. This variable should be written by a meter reader as its first step in reading flow data. The met…
1.3.6.1.2.1.40.1.3.1.5ColumnflowReaderPreviousTimeread-onlycurrentTime this meter reader began the collection before last.
1.3.6.1.2.1.40.1.3.1.6ColumnflowReaderStatusread-createcurrentThe status of this FlowReaderInfoEntry. A value of active(1) implies that the associated reader should be collecting data from the meter. Once this variable ha…
1.3.6.1.2.1.40.1.3.1.7ColumnflowReaderRuleSetread-createcurrentAn index to the array of RuleSets. Specifies a set of rules of interest to this meter reader. The reader will attempt to collect any data generated by the mete…
1.3.6.1.2.1.40.1.4TableflowManagerInfoTablenot-accessiblecurrentAn array of information about managers which have registered their intent to run RuleSets on this meter.
1.3.6.1.2.1.40.1.4.1RowflowManagerInfoEntrynot-accessiblecurrentInformation about a particular meter 'task.' By creating an entry in this table and activating it, a manager requests that the meter 'run' the indicated RuleSe…
1.3.6.1.2.1.40.1.4.1.1ColumnflowManagerIndexnot-accessiblecurrentAn index which selects an entry in the flowManagerInfoTable.
1.3.6.1.2.1.40.1.4.1.2ColumnflowManagerCurrentRuleSetread-createcurrentIndex to the array of RuleSets. Specifies which set of rules is the 'current' one for this task. The meter will be 'running' the current RuleSet if this row's …
1.3.6.1.2.1.40.1.4.1.3ColumnflowManagerStandbyRuleSetread-createcurrentIndex to the array of RuleSets. After reaching HighWaterMark (see below) the manager will switch to using the task's StandbyRuleSet in place of its CurrentRule…
1.3.6.1.2.1.40.1.4.1.4ColumnflowManagerHighWaterMarkread-createcurrentA value expressed as a percentage, interpreted by the meter as an indication of how full the flow table should be before it should switch to the standby RuleSe…
1.3.6.1.2.1.40.1.4.1.5ColumnflowManagerCounterWrapread-createdeprecatedSpecifies whether PDU and octet counters should wrap when they reach the top of their range (normal behaviour for Counter64 objects), or whether their scale fa…
1.3.6.1.2.1.40.1.4.1.6ColumnflowManagerOwnerread-createcurrentIdentifies the manager which created this row.
1.3.6.1.2.1.40.1.4.1.7ColumnflowManagerTimeStampread-onlycurrentTime this row was last changed by its manager.
1.3.6.1.2.1.40.1.4.1.8ColumnflowManagerStatusread-createcurrentThe status of this row in the flowManagerInfoTable. A value of active(1) implies that this task may be activated, by setting its CurrentRuleSet and StandbyRule…
1.3.6.1.2.1.40.1.4.1.9ColumnflowManagerRunningStandbyread-createcurrentSet to true(1) by the meter to indicate that it has switched to runnning this task's StandbyRuleSet in place of its CurrentRuleSet. To switch back to the Curre…
1.3.6.1.2.1.40.1.5ScalarflowFloodMarkread-writecurrentA value expressed as a percentage, interpreted by the meter as an indication of how full the flow table should be before it should take some action to avoid ru…
1.3.6.1.2.1.40.1.6ScalarflowInactivityTimeoutread-writecurrentThe time in seconds since the last packet seen, after which a flow becomes 'idle.' Note that although a flow may be idle, it will not be discarded (and its mem…
1.3.6.1.2.1.40.1.7ScalarflowActiveFlowsread-onlycurrentThe number of flows which are currently in use.
1.3.6.1.2.1.40.1.8ScalarflowMaxFlowsread-onlycurrentThe maximum number of flows allowed in the meter's flow table. At present this is determined when the meter is first started up.
1.3.6.1.2.1.40.1.9ScalarflowFloodModeread-writecurrentIndicates that the meter has passed its FloodMark and is not running in its normal mode. When the manager notices this it should take action to remedy the prob…
1.3.6.1.2.1.40.2NodeflowData
1.3.6.1.2.1.40.2.1TableflowDataTablenot-accessiblecurrentThe list of all flows being measured.
1.3.6.1.2.1.40.2.1.1RowflowDataEntrynot-accessiblecurrentThe flow data record for a particular flow.
1.3.6.1.2.1.40.2.1.1.1ColumnflowDataIndexnot-accessiblecurrentValue of this flow data record's index within the meter's flow table.
1.3.6.1.2.1.40.2.1.1.2ColumnflowDataTimeMarknot-accessiblecurrentA TimeFilter for this entry. Allows GetNext and GetBulk to find flow table rows which have changed since a specified value of the meter's Uptime.
1.3.6.1.2.1.40.2.1.1.3ColumnflowDataStatusread-onlydeprecatedStatus of this flow data record.
1.3.6.1.2.1.40.2.1.1.4ColumnflowDataSourceInterfaceread-onlycurrentIndex of the interface associated with the source address for this flow. It's value is one of those contained in the ifIndex field of the meter's interfaces ta…
1.3.6.1.2.1.40.2.1.1.5ColumnflowDataSourceAdjacentTyperead-onlycurrentAdjacent address type of the source for this flow. If metering is being performed at the network level, AdjacentType will indicate the medium for the interface…
1.3.6.1.2.1.40.2.1.1.6ColumnflowDataSourceAdjacentAddressread-onlycurrentAddress of the adjacent device on the path for the source for this flow.
1.3.6.1.2.1.40.2.1.1.7ColumnflowDataSourceAdjacentMaskread-onlycurrent1-bits in this mask indicate which bits must match when comparing the adjacent source address for this flow.
1.3.6.1.2.1.40.2.1.1.8ColumnflowDataSourcePeerTyperead-onlycurrentPeer address type of the source for this flow.
1.3.6.1.2.1.40.2.1.1.9ColumnflowDataSourcePeerAddressread-onlycurrentAddress of the peer device for the source of this flow.
1.3.6.1.2.1.40.2.1.1.10ColumnflowDataSourcePeerMaskread-onlycurrent1-bits in this mask indicate which bits must match when comparing the source peer address for this flow.
1.3.6.1.2.1.40.2.1.1.11ColumnflowDataSourceTransTyperead-onlycurrentTransport address type of the source for this flow. The value of this attribute will depend on the peer address type.
1.3.6.1.2.1.40.2.1.1.12ColumnflowDataSourceTransAddressread-onlycurrentTransport address for the source of this flow.
1.3.6.1.2.1.40.2.1.1.13ColumnflowDataSourceTransMaskread-onlycurrent1-bits in this mask indicate which bits must match when comparing the transport source address for this flow.
1.3.6.1.2.1.40.2.1.1.14ColumnflowDataDestInterfaceread-onlycurrentIndex of the interface associated with the dest address for this flow. This value is one of the values contained in the ifIndex field of the interfaces table.
1.3.6.1.2.1.40.2.1.1.15ColumnflowDataDestAdjacentTyperead-onlycurrentAdjacent address type of the destination for this flow.
1.3.6.1.2.1.40.2.1.1.16ColumnflowDataDestAdjacentAddressread-onlycurrentAddress of the adjacent device on the path for the destination for this flow.
1.3.6.1.2.1.40.2.1.1.17ColumnflowDataDestAdjacentMaskread-onlycurrent1-bits in this mask indicate which bits must match when comparing the adjacent destination address for this flow.
1.3.6.1.2.1.40.2.1.1.18ColumnflowDataDestPeerTyperead-onlycurrentPeer address type of the destination for this flow.
1.3.6.1.2.1.40.2.1.1.19ColumnflowDataDestPeerAddressread-onlycurrentAddress of the peer device for the destination of this flow.
1.3.6.1.2.1.40.2.1.1.20ColumnflowDataDestPeerMaskread-onlycurrent1-bits in this mask indicate which bits must match when comparing the destination peer type for this flow.
1.3.6.1.2.1.40.2.1.1.21ColumnflowDataDestTransTyperead-onlycurrentTransport address type of the destination for this flow. The value of this attribute will depend on the peer address type.
1.3.6.1.2.1.40.2.1.1.22ColumnflowDataDestTransAddressread-onlycurrentTransport address for the destination of this flow.
1.3.6.1.2.1.40.2.1.1.23ColumnflowDataDestTransMaskread-onlycurrent1-bits in this mask indicate which bits must match when comparing the transport destination address for this flow.
1.3.6.1.2.1.40.2.1.1.24ColumnflowDataPDUScaleread-onlycurrentThe scale factor applied to this particular flow. Indicates the number of bits the PDU counter values should be moved left to obtain the actual values.
1.3.6.1.2.1.40.2.1.1.25ColumnflowDataOctetScaleread-onlycurrentThe scale factor applied to this particular flow. Indicates the number of bits the octet counter values should be moved left to obtain the actual values.
1.3.6.1.2.1.40.2.1.1.26ColumnflowDataRuleSetnot-accessiblecurrentThe RuleSet number of the RuleSet which created this flow. Allows a manager to use GetNext or GetBulk requests to find flows belonging to a particular RuleSet.
1.3.6.1.2.1.40.2.1.1.27ColumnflowDataToOctetsread-onlycurrentThe count of octets flowing from source to destination for this flow.
1.3.6.1.2.1.40.2.1.1.28ColumnflowDataToPDUsread-onlycurrentThe count of packets flowing from source to destination for this flow.
1.3.6.1.2.1.40.2.1.1.29ColumnflowDataFromOctetsread-onlycurrentThe count of octets flowing from destination to source for this flow.
1.3.6.1.2.1.40.2.1.1.30ColumnflowDataFromPDUsread-onlycurrentThe count of packets flowing from destination to source for this flow.
1.3.6.1.2.1.40.2.1.1.31ColumnflowDataFirstTimeread-onlycurrentThe time at which this flow was first entered in the table
1.3.6.1.2.1.40.2.1.1.32ColumnflowDataLastActiveTimeread-onlycurrentThe last time this flow had activity, i.e. the time of arrival of the most recent PDU belonging to this flow.
1.3.6.1.2.1.40.2.1.1.33ColumnflowDataSourceSubscriberIDread-onlycurrentSubscriber ID associated with the source address for this flow. A Subscriber ID is an unspecified text string, used to ascribe traffic flows to individual user…
1.3.6.1.2.1.40.2.1.1.34ColumnflowDataDestSubscriberIDread-onlycurrentSubscriber ID associated with the destination address for this flow. A Subscriber ID is an unspecified text string, used to ascribe traffic flows to individual…
1.3.6.1.2.1.40.2.1.1.35ColumnflowDataSessionIDread-onlycurrentSession ID for this flow. Such an ID might be allocated by a network access server to distinguish a series of sessions between the same pair of addresses, whic…
1.3.6.1.2.1.40.2.1.1.36ColumnflowDataSourceClassread-onlycurrentSource class for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table.
1.3.6.1.2.1.40.2.1.1.37ColumnflowDataDestClassread-onlycurrentDestination class for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table.
1.3.6.1.2.1.40.2.1.1.38ColumnflowDataClassread-onlycurrentClass for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table.
1.3.6.1.2.1.40.2.1.1.39ColumnflowDataSourceKindread-onlycurrentSource kind for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table.
1.3.6.1.2.1.40.2.1.1.40ColumnflowDataDestKindread-onlycurrentDestination kind for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table.
1.3.6.1.2.1.40.2.1.1.41ColumnflowDataKindread-onlycurrentClass for this flow. Determined by the rules, set by a PushRule action when this flow was entered in the table.
1.3.6.1.2.1.40.2.2TableflowColumnActivityTablenot-accessibledeprecatedIndex into the Flow Table. Allows a meter reader to retrieve a list containing the flow table indexes of flows which were last active at or after a given time,…
1.3.6.1.2.1.40.2.2.1RowflowColumnActivityEntrynot-accessibledeprecatedThe Column Activity Entry for a particular attribute, activity time and flow.
1.3.6.1.2.1.40.2.2.1.1ColumnflowColumnActivityAttributeread-onlydeprecatedSpecifies the attribute for which values are required from active flows.
1.3.6.1.2.1.40.2.2.1.2ColumnflowColumnActivityTimeread-onlydeprecatedThis variable is a copy of flowDataLastActiveTime in the flow data record identified by the flowColumnActivityIndex value of this flowColumnActivityTable entry.
1.3.6.1.2.1.40.2.2.1.3ColumnflowColumnActivityIndexread-onlydeprecatedIndex of a flow table entry which was active at or after a specified flowColumnActivityTime.
1.3.6.1.2.1.40.2.2.1.4ColumnflowColumnActivityDataread-onlydeprecatedCollection of attribute data for flows active after flowColumnActivityTime. Within the OCTET STRING is a sequence of { flow index, attribute value } pairs, one…
1.3.6.1.2.1.40.2.3TableflowDataPackageTablenot-accessiblecurrentIndex into the Flow Table. Allows a meter reader to retrieve a sequence containing the values of a specified set of attributes for a flow which came from a spe…
1.3.6.1.2.1.40.2.3.1RowflowDataPackageEntrynot-accessiblecurrentThe data package containing selected variables from active rows in the flow table.
1.3.6.1.2.1.40.2.3.1.1ColumnflowPackageSelectornot-accessiblecurrentSpecifies the attributes for which values are required from an active flow. These are encoded as a sequence of octets each containing a FlowAttribute number, p…
1.3.6.1.2.1.40.2.3.1.2ColumnflowPackageRuleSetnot-accessiblecurrentSpecifies the index (in the flowRuleSetInfoTable) of the rule set which produced the required flow.
1.3.6.1.2.1.40.2.3.1.3ColumnflowPackageTimenot-accessiblecurrentThis variable is a copy of flowDataLastActiveTime in the flow data record identified by the flowPackageIndex value of this flowPackageTable entry.
1.3.6.1.2.1.40.2.3.1.4ColumnflowPackageIndexnot-accessiblecurrentIndex of a flow table entry which was active at or after a specified flowPackageTime.
1.3.6.1.2.1.40.2.3.1.5ColumnflowPackageDataread-onlycurrentA collection of attribute values for a single flow, as specified by this row's indexes. The attribute values are contained within a BER-encoded sequence [ASN-1…
1.3.6.1.2.1.40.3NodeflowRules
1.3.6.1.2.1.40.3.1TableflowRuleTablenot-accessiblecurrentContains all the RuleSets which may be used by the meter.
1.3.6.1.2.1.40.3.1.1RowflowRuleEntrynot-accessiblecurrentThe rule record itself.
1.3.6.1.2.1.40.3.1.1.1ColumnflowRuleSetnot-accessiblecurrentSelects a RuleSet from the array of RuleSets.
1.3.6.1.2.1.40.3.1.1.2ColumnflowRuleIndexnot-accessiblecurrentThe index into the Rule table. N.B: These values will normally be consecutive, given the fall-through semantics of processing the table.
1.3.6.1.2.1.40.3.1.1.3ColumnflowRuleSelectorread-writecurrentIndicates the attribute to be matched. null(0) is a special case; null rules always succeed. matchingStoD(50) is set by the meter's Packet Matching Engine. Its…
1.3.6.1.2.1.40.3.1.1.4ColumnflowRuleMaskread-writecurrentThe initial mask used to compute the desired value. If the mask is zero the rule's test will always succeed.
1.3.6.1.2.1.40.3.1.1.5ColumnflowRuleMatchedValueread-writecurrentThe resulting value to be matched for equality. Specifically, if the attribute chosen by the flowRuleSelector logically ANDed with the mask specified by the fl…
1.3.6.1.2.1.40.3.1.1.6ColumnflowRuleActionread-writecurrentThe action to be taken if this rule's test succeeds, or if the meter's 'test' flag is off. Actions are opcodes for the meter's Packet Matching Engine; details …
1.3.6.1.2.1.40.3.1.1.7ColumnflowRuleParameterread-writecurrentA parameter value providing extra information for this rule's action. Most of the actions use the parameter value to specify which rule to execute after this r…
1.3.6.1.2.1.40.4NodeflowMIBConformance
1.3.6.1.2.1.40.4.1NodeflowMIBCompliances
1.3.6.1.2.1.40.4.1.1ComplianceflowMIBCompliancecurrentThe compliance statement for a Traffic Flow Meter.
1.3.6.1.2.1.40.4.2NodeflowMIBGroups
1.3.6.1.2.1.40.4.2.1GroupflowControlGroupdeprecatedThe control group defines objects which are used to control an accounting meter.
1.3.6.1.2.1.40.4.2.2GroupflowDataTableGroupdeprecatedThe flow table group defines objects which provide the structure for the flow table, including the creation time and activity time indexes into it. In addition…
1.3.6.1.2.1.40.4.2.3GroupflowDataScaleGroupdeprecatedThe flow scale group defines objects which specify scale factors for counters.
1.3.6.1.2.1.40.4.2.4GroupflowDataSubscriberGroupcurrentThe flow subscriber group defines objects which may be used to identify the end point(s) of a flow.
1.3.6.1.2.1.40.4.2.5GroupflowDataColumnTableGroupdeprecatedThe flow column table group defines objects which can be used to collect part of a column of attribute values from the flow table.
1.3.6.1.2.1.40.4.2.6GroupflowDataPackageGroupcurrentThe data package group defines objects which can be used to collect a specified set of attribute values from a row of the flow table.
1.3.6.1.2.1.40.4.2.7GroupflowRuleTableGroupcurrentThe rule table group defines objects which hold the set(s) of rules specifying which traffic flows are to be accounted for.
1.3.6.1.2.1.40.4.2.8GroupflowDataScaleGroup2currentThe flow scale group defines objects which specify scale factors for counters. This group replaces the earlier version of flowDataScaleGroup above (now depreca…
1.3.6.1.2.1.40.4.2.9GroupflowControlGroup2currentThe control group defines objects which are used to control an accounting meter. It replaces the earlier version of flowControlGroup above (now deprecated).
Type Definitions
NameSyntaxStatusDescription
ActionNumberINTEGER { ignore(1), noMatch(2), count(3), countPkt(4), return(5), gosub(6), gosubAct(7), assign(8), assignAct(9), goto(10), gotoAct(11), pushRuleTo(12), pushRuleToAct(13), pushPktTo(14), pushPktToAct(15), popTo(16), popToAct(17) }currentUniquely identifies the action of a rule, i.e. the Pattern Matching Engine's opcode number. Details of the opcodes are given in the 'Traffic Flow Measurement: Architecture' document [RTFM-ARC].
AdjacentAddressOCTET STRING (SIZE (3..20))currentSpecifies the value of an adjacent address. May be a Medium Access Control (MAC) address or (if metering is taking place inside a tunnel) a PeerAddress (see above). MAC Address format depends on the actual medium, as fo…
AdjacentTypeINTEGER { ip(1), nsap(3), ethernet(7), tokenring(9), ipx(11), appletalk(12), decnet(13), fddi(15) }currentIndicates the type of an adjacent address. May be a medium type or (if metering is taking place inside a tunnel) a PeerType (see above). The values used for IEEE 802 medium types are from the 'Network Management Paramet…
FlowAttributeNumberINTEGER { flowIndex(1), flowStatus(2), flowTimeMark(3), sourceInterface(4), sourceAdjacentType(5), sourceAdjacentAddress(6), sourceAdjacentMask(7), sourcePeerType(8), sourcePeerAddress(9), sourcePeerMask(10), sourceTransType(11), sourceTransAddress(12), sourceTransMask(13), destInterface(14), destAdjacentType(15), destAdjacentAddress(16), destAdjacentMask(17), destPeerType(18), destPeerAddress(19), destPeerMask(20), destTransType(21), destTransAddress(22), destTransMask(23), pduScale(24), octetScale(25), ruleSet(26), toOctets(27), toPDUs(28), fromOctets(29), fromPDUs(30), firstTime(31), lastActiveTime(32), sourceSubscriberID(33), destSubscriberID(34), sessionID(35), sourceClass(36), destClass(37), flowClass(38), sourceKind(39), destKind(40), flowKind(41) }currentUniquely identifies an attribute within a flow data record.
PeerAddressOCTET STRING (SIZE (3..20))currentSpecifies the value of a peer address for various network protocols. Address format depends on the actual protocol, as indicated below: IPv4: ipv4(1) 4-octet IpAddress (defined in the SNMPv2 SMI [RFC2578]) IPv6: ipv6(2)…
PeerTypeINTEGER { ipv4(1), ipv6(2), nsap(3), ipx(11), appletalk(12), decnet(13) }currentIndicates the type of a PeerAddress (see below). The values used are from the 'Address Family Numbers' section of the Assigned Numbers RFC [ASG-NBR]. Peer types from other address families may also be used, provided onl…
RuleAddressOCTET STRING (SIZE (2..20))currentSpecifies the value of an address. Is a superset of MediumAddress, PeerAddress and TransportAddress.
RuleAttributeNumberINTEGER { null(0), sourceInterface(4), sourceAdjacentType(5), sourceAdjacentAddress(6), sourcePeerType(8), sourcePeerAddress(9), sourceTransType(11), sourceTransAddress(12), destInterface(14), destAdjacentType(15), destAdjacentAddress(16), destPeerType(18), destPeerAddress(19), destTransType(21), destTransAddress(22), sourceSubscriberID(33), destSubscriberID(34), sessionID(35), sourceClass(36), destClass(37), flowClass(38), sourceKind(39), destKind(40), flowKind(41), matchingStoD(50), v1(51), v2(52), v3(53), v4(54), v5(55) }currentUniquely identifies an attribute which may be tested in a rule. These include attributes whose values come directly from (or are computed from) the flow's packets, and the five 'meter' variables used to hold an Attribut…
TransportAddressOCTET STRING (SIZE (2))currentSpecifies the value of a transport address for various network protocols. Format as follows: IP: 2-octet UDP or TCP port number Other protocols: 2-octet port number
TransportTypeInteger32 (1..255)currentIndicates the type of a TransportAddress (see below). Values will depend on the actual protocol; for IP they will be those given in the 'Protocol Numbers' section of the Assigned Numbers RFC [ASG-NBR], including icmp(1)…
UTF8OwnerStringOCTET STRING (SIZE (0..127))currentAn administratively assigned name for the owner of a resource, conceptually the same as OwnerString in the RMON MIB [RMON-MIB]. To facilitate internationalisation, this name information is represented using the ISO/IEC …