1.3.6.1.4.1.52642.1.1.10.2.105IdentityfsFiberMIBThis module defines fs fiber module information mibs.
1.3.6.1.4.1.52642.1.1.10.2.105.1NodefsFiberMIBObjects
1.3.6.1.4.1.52642.1.1.10.2.105.1.1TablefsFiberTablenot-accessiblecurrentA table for getting Fiber Module information
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1RowfsFiberEntrynot-accessiblecurrentEntry of a Fiber Module information.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.1ColumnfsFiberPortIndexnot-accessiblecurrentPort index of the port.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.2ColumnfsFiberPortDescrread-onlycurrentDiscription of the port.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.3ColumnfsFiberTransceiverTyperead-onlycurrentTransceiver type of the Fiber module insered into the port.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.4ColumnfsFiberConnectorTyperead-onlycurrentConnector type of the Fiber module insered into the port. If the transceiver type of Fiber module is unknown(1), then this object contains a zero value.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.5ColumnfsFiberWavelengthread-onlycurrentThe value of wavelength of the Fiber module insered into the port. If the transceiver type of Fiber module is either fiber100CopperSFP(7) or fiber1000CopperSFP…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.6ColumnfsFiberTransferDistanceSMFread-onlycurrentThe value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while opera…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.7ColumnfsFiberTransferDistance62point5umOM1read-onlycurrentThe value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while opera…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.8ColumnfsFiberTransferDistance62point5umread-onlycurrentThe value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while opera…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.9ColumnfsFiberTransferDistance50umOM2read-onlycurrentThe value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while opera…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.10ColumnfsFiberTransferDistance50umread-onlycurrentThe value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while opera…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.11ColumnfsFiberTransferDistance50umOM3read-onlycurrentThe value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while opera…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.12ColumnfsFiberTransferDistanceEBW50umread-onlycurrentThe value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while opera…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.13ColumnfsFiberTransferDistanceCopperread-onlycurrentThe value of transfer distance of the Fiber module insered into the port. This value specifies the link length that is supported by the transceiver while opera…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.14ColumnfsFiberTransferDistanceCableAssemblyread-onlycurrentThe value of transfer distance of the Fiber module insered into the port. This value specifies the link length of the Cable assembly passive. The value is in u…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.15ColumnfsFiberDDMSupportStatusread-onlycurrentThis object indicates that whether the Digital Diagnostic Monitors is implemeted.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.16ColumnfsFiberSerialNumberread-onlycurrentThe serial number of the Fiber module insered into the port.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.17ColumnfsFiberTempread-onlycurrentThe temperature of the Fiber module insered into the port. The value is in units of degrees Celsius. If the fsFiberDDMSupportStatus is false, the temperature v…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.18ColumnfsFiberTempStatusread-onlycurrentThe status ok(2) indicates that the temperature of the Fiber module is in the normal level. The status warning(3) indicates that the temperature of the Fiber m…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.19ColumnfsFiberVoltageread-onlycurrentThe voltage of the Fiber module insered into the port. The value is in units of mVolts. If the fsFiberDDMSupportStatus is false, the voltage value is 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.20ColumnfsFiberVoltageStatusread-onlycurrentThe status ok(2) indicates that the voltage of the Fiber module is in the normal level. The status warning(3) indicates that the voltage of the Fiber module ex…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.21ColumnfsFiberBiasread-onlycurrentThe bias of the Fiber module insered into the port. The value is in units of uA. If the fsFiberDDMSupportStatus is false or the Fiber module type is neither SF…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.22ColumnfsFiberBiasStatusread-onlycurrentThe status ok(2) indicates that the bias of the Fiber module is in the normal level. The status warning(3) indicates that the bias of the Fiber module exceeds …
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.23ColumnfsFiberChannel1Biasread-onlycurrentThe bias in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of uA. If the fsFiberDDMSupportStatus is false or the Fiber module…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.24ColumnfsFiberChannel1BiasStatusread-onlycurrentThe status ok(2) indicates that the bias in the Channel 1 of QSFP+ is in the normal level. The status warning(3) indicates that the bias in the Channel 1 excee…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.25ColumnfsFiberChannel2Biasread-onlycurrentThe bias in Channel 2 of the QSFP+ Fiber module insered into the port. The value is in units of uA. If the fsFiberDDMSupportStatus is false or the Fiber module…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.26ColumnfsFiberChannel2BiasStatusread-onlycurrentThe status ok(2) indicates that the bias in the Channel 2 of QSFP+ is in the normal level. The status warning(3) indicates that the bias in the Channel 2 excee…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.27ColumnfsFiberChannel3Biasread-onlycurrentThe bias in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of uA. If the fsFiberDDMSupportStatus is false or the Fiber module…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.28ColumnfsFiberChannel3BiasStatusread-onlycurrentThe status ok(2) indicates that the bias in the Channel 3 of QSFP+ is in the normal level. The status warning(3) indicates that the bias in the Channel 3 excee…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.29ColumnfsFiberChannel4Biasread-onlycurrentThe bias in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of uA. If the fsFiberDDMSupportStatus is false or the Fiber module…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.30ColumnfsFiberChannel4BiasStatusread-onlycurrentThe status ok(2) indicates that the bias in the Channel 4 of QSFP+ is in the normal level. The status warning(3) indicates that the bias in the Channel 4 excee…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.31ColumnfsFiberRXpowerIntegerpartread-onlycurrentThe integer part of Rx power of the Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is false or the Fiber modu…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.32ColumnfsFiberRXpowerDecimalpartread-onlycurrentThe decimal part of Rx power of the Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is false or the Fiber modu…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.33ColumnfsFiberRXpowertyperead-onlycurrentThe value indicates whether the received power measurement represents average input optical power(2) or oma(3). If the fsFiberDDMSupportStatus is false or the …
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.34ColumnfsFiberRXpowerStatusread-onlycurrentThe status ok(2) indicates that the Rx power of the Fiber module is in the normal level. The status warning(3) indicates that the Rx power of the Fiber module …
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.35ColumnfsFiberChannel1RXpowerIntegerpartread-onlycurrentThe integer part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.36ColumnfsFiberChannel1RXpowerDecimalpartread-onlycurrentThe decimal part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.37ColumnfsFiberChannel1RXpowertyperead-onlycurrentThe value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 1 of QSFP+. If the fsFiberDDMSupportS…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.38ColumnfsFiberChannel1RXpowerStatusread-onlycurrentThe status ok(2) indicates that the Rx power in the Channel 1 of QSFP+ is in the normal level. The status warning(3) indicates that the Rx power in the Channel…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.39ColumnfsFiberChannel2RXpowerIntegerpartread-onlycurrentThe integer part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.40ColumnfsFiberChannel2RXpowerDecimalpartread-onlycurrentThe decimal part of Rx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.41ColumnfsFiberChannel2RXpowertyperead-onlycurrentThe value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 2 of QSFP+. If the fsFiberDDMSupportS…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.42ColumnfsFiberChannel2RXpowerStatusread-onlycurrentThe status ok(2) indicates that the Rx power in the Channel 2 of QSFP+ is in the normal level. The status warning(3) indicates that the Rx power in the Channel…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.43ColumnfsFiberChannel3RXpowerIntegerpartread-onlycurrentThe integer part of Rx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.44ColumnfsFiberChannel3RXpowerDecimalpartread-onlycurrentThe decimal part of Rx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.45ColumnfsFiberChannel3RXpowertyperead-onlycurrentThe value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 3 of QSFP+. If the fsFiberDDMSupportS…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.46ColumnfsFiberChannel3RXpowerStatusread-onlycurrentThe status ok(2) indicates that the Rx power in the Channel 3 of QSFP+ is in the normal level. The status warning(3) indicates that the Rx power in the Channel…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.47ColumnfsFiberChannel4RXpowerIntegerpartread-onlycurrentThe integer part of Rx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.48ColumnfsFiberChannel4RXpowerDecimalpartread-onlycurrentThe decimal part of Rx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.49ColumnfsFiberChannel4RXpowertyperead-onlycurrentThe value indicates whether the received power measurement represents average input optical power(2) or oma(3) in Channel 4 of QSFP+. If the fsFiberDDMSupportS…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.50ColumnfsFiberChannel4RXpowerStatusread-onlycurrentThe status ok(2) indicates that the Rx power in the Channel 4 of QSFP+ is in the normal level. The status warning(3) indicates that the Rx power in the Channel…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.51ColumnfsFiberTXpowerIntegerpartread-onlycurrentThe integer part of Tx power of the Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is false or the Fiber modu…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.52ColumnfsFiberTXpowerDecimalpartread-onlycurrentThe decimal part of Tx power of the Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is false or the Fiber modu…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.53ColumnfsFiberTXpowerStatusread-onlycurrentThe status ok(2) indicates that the Tx power of the Fiber module is in the normal level. The status warning(3) indicates that the Tx power of the Fiber module …
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.54ColumnfsFiberChannel1TXpowerIntegerpartread-onlycurrentThe integer part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.55ColumnfsFiberChannel1TXpowerDecimalpartread-onlycurrentThe decimal part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.56ColumnfsFiberChannel1TXpowerStatusread-onlycurrentThe status ok(2) indicates that the Tx power in the Channel 1 of QSFP+ is in the normal level. The status warning(3) indicates that the Tx power in the Channel…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.57ColumnfsFiberChannel2TXpowerIntegerpartread-onlycurrentThe integer part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.58ColumnfsFiberChannel2TXpowerDecimalpartread-onlycurrentThe decimal part of Tx power in Channel 1 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.59ColumnfsFiberChannel2TXpowerStatusread-onlycurrentThe status ok(2) indicates that the Tx power in the Channel 2 of QSFP+ is in the normal level. The status warning(3) indicates that the Tx power in the Channel…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.60ColumnfsFiberChannel3TXpowerIntegerpartread-onlycurrentThe integer part of Tx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.61ColumnfsFiberChannel3TXpowerDecimalpartread-onlycurrentThe decimal part of Tx power in Channel 3 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.62ColumnfsFiberChannel3TXpowerStatusread-onlycurrentThe status ok(2) indicates that the Tx power in the Channel 3 of QSFP+ is in the normal level. The status warning(3) indicates that the Tx power in the Channel…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.63ColumnfsFiberChannel4TXpowerIntegerpartread-onlycurrentThe integer part of Tx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.64ColumnfsFiberChannel4TXpowerDecimalpartread-onlycurrentThe decimal part of Tx power in Channel 4 of the QSFP+ Fiber module insered into the port. The value is in units of dbm. If the fsFiberDDMSupportStatus is fals…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.65ColumnfsFiberChannel4TXpowerStatusread-onlycurrentThe status ok(2) indicates that the Tx power in the Channel 4 of QSFP+ is in the normal level. The status warning(3) indicates that the Tx power in the Channel…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.66ColumnfsFiberRXpowerSignread-onlycurrentThe sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.67ColumnfsFiberChannel1RXpowerSignread-onlycurrentThe sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.68ColumnfsFiberChannel2RXpowerSignread-onlycurrentThe sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.69ColumnfsFiberChannel3RXpowerSignread-onlycurrentThe sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.70ColumnfsFiberChannel4RXpowerSignread-onlycurrentThe sign (-1) indicates that the Rx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.71ColumnfsFiberTXpowerSignread-onlycurrentThe sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.72ColumnfsFiberChannel1TXpowerSignread-onlycurrentThe sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.73ColumnfsFiberChannel2TXpowerSignread-onlycurrentThe sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.74ColumnfsFiberChannel3TXpowerSignread-onlycurrentThe sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.75ColumnfsFiberChannel4TXpowerSignread-onlycurrentThe sign (-1) indicates that the Tx power value is lower than 0, while sign (1) is higher than 0.
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.76ColumnfsFiberRXpowerIntegerread-onlycurrentThe integer of Rx power of the Fiber module insered into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fiber modu…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.77ColumnfsFiberChannel1RXpowerIntegerread-onlycurrentThe integer part of Rx power in Channel 1 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus i…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.78ColumnfsFiberChannel2RXpowerIntegerread-onlycurrentThe integer part of Rx power in Channel 1 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus i…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.79ColumnfsFiberChannel3RXpowerIntegerread-onlycurrentThe integer part of Rx power in Channel 3 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus i…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.80ColumnfsFiberChannel4RXpowerIntegerread-onlycurrentThe integer part of Rx power in Channel 4 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus i…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.81ColumnfsFiberTXpowerIntegerread-onlycurrentThe integer part of Tx power of the Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus is false or the Fibe…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.82ColumnfsFiberChannel1TXpowerIntegerread-onlycurrentThe integer part of Tx power in Channel 1 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus i…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.83ColumnfsFiberChannel2TXpowerIntegerread-onlycurrentThe integer part of Tx power in Channel 1 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus i…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.84ColumnfsFiberChannel3TXpowerIntegerread-onlycurrentThe integer part of Tx power in Channel 3 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus i…
1.3.6.1.4.1.52642.1.1.10.2.105.1.1.1.85ColumnfsFiberChannel4TXpowerIntegerread-onlycurrentThe integer part of Tx power in Channel 4 of the QSFP+ Fiber module inserted into the port. The value is in units of 0.01 dbm. If the fsFiberDDMSupportStatus i…
1.3.6.1.4.1.52642.1.1.10.2.105.1.2TablefsFiberVendorTablenot-accessiblecurrentA table of Vendor info entries.
1.3.6.1.4.1.52642.1.1.10.2.105.1.2.1RowfsFiberVendorEntrynot-accessiblecurrentEntry contains Vendor info.
1.3.6.1.4.1.52642.1.1.10.2.105.1.2.1.1ColumnfsFiberVendorPortIndexread-onlycurrentThe port index of Vendor info .
1.3.6.1.4.1.52642.1.1.10.2.105.1.2.1.2ColumnfsFiberVendorNameread-onlycurrentThe description of vendor name.
1.3.6.1.4.1.52642.1.1.10.2.105.1.2.1.3ColumnfsFiberVendorOUIread-onlycurrentAdded by Observium developers
1.3.6.1.4.1.52642.1.1.10.2.105.1.2.1.4ColumnfsFiberVendorPNread-onlycurrentAdded by Observium developers
1.3.6.1.4.1.52642.1.1.10.2.105.1.2.1.5ColumnfsFiberVendorRevread-onlycurrentAdded by Observium developers
1.3.6.1.4.1.52642.1.1.10.2.105.1.2.1.6ColumnfsFiberVendorDateread-onlycurrentAdded by Observium developers
1.3.6.1.4.1.52642.1.1.10.2.105.1.2.1.7ColumnfsFiberVendorEncodingread-onlycurrentAdded by Observium developers
1.3.6.1.4.1.52642.1.1.10.2.105.2NodefsFiberAntifakeMIBTraps
1.3.6.1.4.1.52642.1.1.10.2.105.2.1ScalarfsFiberAntifakeIntfNameDescaccessible-for-notifycurrentThe description of the interface.
1.3.6.1.4.1.52642.1.1.10.2.105.2.2ScalarfsFiberAntifakeSerialNumberDescaccessible-for-notifycurrentThe description of the serial number of the fiber module.
1.3.6.1.4.1.52642.1.1.10.2.105.2.3NotificationfsFiberAntifakeTrapcurrentWhen detect the fiber module is not original fs fiber module, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.105.3NodefsFiberMIBConformance
1.3.6.1.4.1.52642.1.1.10.2.105.3.1NodefsFiberMIBCompliances
1.3.6.1.4.1.52642.1.1.10.2.105.3.1.1CompliancefsFiberMIBConpliancecurrentThe compliance statement for entities which implement the FS Fiber MIB
1.3.6.1.4.1.52642.1.1.10.2.105.3.2NodefsFiberMIBGroups
1.3.6.1.4.1.52642.1.1.10.2.105.3.2.1GroupfsFiberMIBGroupcurrentA collection of objects providing Fiber managment.
1.3.6.1.4.1.52642.1.1.10.2.105.3.2.2GroupfsFiberAntifakeIntfNameDescGroupcurrentObjects that providing a literal description of the interface.
1.3.6.1.4.1.52642.1.1.10.2.105.3.2.3GroupfsFiberAntifakeSerialNumberDescGroupcurrentObjects that providing a literal description of the fiber module serial number.