FS-PFC-MIB

24 objects
This module defines fs priority-flow-control interface priority counter mibs.
OIDNameAccessStatusDescription
1.3.6.1.4.1.52642.1.1.10.2.157IdentityfsPfcMIBThis module defines fs priority-flow-control interface priority counter mibs.
1.3.6.1.4.1.52642.1.1.10.2.157.1NodefsPfcCounterMIBObjects
1.3.6.1.4.1.52642.1.1.10.2.157.1.1TablefsPfcIfPriorityCounterTablenot-accessiblecurrentlist of Pfc interface priority counter objects.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1RowfsPfcIfPriorityCounterEntrynot-accessiblecurrentEntry contains Pfc interface priority counters.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.1ColumnfsIfIndexread-onlycurrentPort index.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.2ColumnfsPfcPriorityread-onlycurrentPFC priority value(0-7).
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.3ColumnfsPfcRequestsread-onlycurrentA count of the invoked PFC M_CONTROL.request primitives. Discontinuities in the value of this counter can occur at re-initialization of the management system, …
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.4ColumnfsPfcRequestsRateread-onlycurrentThe rate of PFC requests.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.5ColumnfsPfcRequestsRate1stread-onlycurrentThe first fastest rate of PFC requests in the history. The unit is pps(packets per second).
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.6ColumnfsPfcRequestsRate1stTimeread-onlycurrentThe moment of the first fastest rate of PFC requests in the history.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.7ColumnfsPfcRequestsRate2ndread-onlycurrentThe second fastest rate of PFC requests in the history. The unit is pps(packets per second).
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.8ColumnfsPfcRequestsRate2ndTimeread-onlycurrentThe moment of the second fastest rate of PFC requests in the history.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.9ColumnfsPfcRequestsRate3rdread-onlycurrentThe third fastest rate of PFC requests in the history. The unit is pps(packets per second).
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.10ColumnfsPfcRequestsRate3rdTimeread-onlycurrentThe moment of the third fastest rate of PFC requests in the history.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.11ColumnfsPfcIndicationsread-onlycurrentA count of the received PFC M_CONTROL.indication primitives. Discontinuities in the value of this counter can occur at re-initialization of the management syst…
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.12ColumnfsPfcIndicationsRateread-onlycurrentThe rate of PFC indications.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.13ColumnfsPfcIndicationsRate1stread-onlycurrentThe first fastest rate of PFC indications in the history. The unit is pps(packets per second).
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.14ColumnfsPfcIndicationsRate1stTimeread-onlycurrentThe moment of the first fastest rate of PFC indications in the history.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.15ColumnfsPfcIndicationsRate2ndread-onlycurrentThe second fastest rate of PFC indications in the history. The unit is pps(packets per second).
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.16ColumnfsPfcIndicationsRate2ndTimeread-onlycurrentThe moment of the second fastest rate of PFC indications in the history.
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.17ColumnfsPfcIndicationsRate3rdread-onlycurrentThe third fastest rate of PFC indications in the history. The unit is pps(packets per second).
1.3.6.1.4.1.52642.1.1.10.2.157.1.1.1.18ColumnfsPfcIndicationsRate3rdTimeread-onlycurrentThe moment of the third fastest rate of PFC indications in the history.
1.3.6.1.4.1.52642.1.1.10.2.157.2NodefsPfcMIBConformance
1.3.6.1.4.1.52642.1.1.10.2.157.2.1GroupfsPfcIfPriorityCounterMIBGroupcurrentA collection of objects contain Pfc interface priority counters.