FS-SYSTEM-MIB

249 objects
This module defines fs system mibs.
OIDNameAccessStatusDescription
1.3.6.1.4.1.52642.1.1.10.2.1IdentityfsSystemMIBThis module defines fs system mibs.
1.3.6.1.4.1.52642.1.1.10.2.1.1NodefsSystemMIBObjects
1.3.6.1.4.1.52642.1.1.10.2.1.1.1ScalarfsSystemHwVersionread-onlycurrentReturn the string of the Revision number of hardware resides on the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.2ScalarfsSystemSwVersionread-onlycurrentReturn the string of the Revision number of software resides on the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.3ScalarfsSystemBootVersionread-onlycurrentReturn the string of the Revision number of BOOT software resides on the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.4ScalarfsSystemSysCtrlVersionread-onlycurrentReturn the string of the Revision number of CTRL software resides on the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.5ScalarfsSystemParametersSaveread-writecurrentSave all parameters changed in configuration by setting this object to any value but 0, set its value to 0 will cause no action of agent, otherwise all changes…
1.3.6.1.4.1.52642.1.1.10.2.1.1.6ScalarfsSystemOutBandRateread-writecurrentDetermine the console(OutBand) baud rate : 9600 - 1,19200 - 2, 38300 - 3, 57600 - 4, 115200 - 5, when the console baud rate is other value will return value 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.7ScalarfsSystemResetread-writecurrentThis Object allow perform soft reset of system by setting its value to none zero. if a soft resetis performed, after this having completed a warm start trap wi…
1.3.6.1.4.1.52642.1.1.10.2.1.1.8ScalarfsSwitchLayerread-onlycurrentWhich layer's device the switch in system
1.3.6.1.4.1.52642.1.1.10.2.1.1.9ScalarfsSystemHwPowerread-onlycurrentThe state of power.
1.3.6.1.4.1.52642.1.1.10.2.1.1.10ScalarfsSystemHwFanread-onlycurrentThe state of fan.
1.3.6.1.4.1.52642.1.1.10.2.1.1.11ScalarfsSystemOutBandTimeoutread-writeobsoleteThe timeout of console.0 indicate that timeout function is disabled.
1.3.6.1.4.1.52642.1.1.10.2.1.1.12ScalarfsSystemTelnetTimeoutread-writeobsoleteThe timeout of telnet.0 indicate that timeout function is disabled.
1.3.6.1.4.1.52642.1.1.10.2.1.1.13ScalarfsSystemMainFileread-onlycurrentReturn the string of the name of main file on the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.14ScalarfsSystemCurrentPowerread-onlycurrentReturn the current power of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.15ScalarfsSystemRemainPowerread-onlycurrentReturn the remain power of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.16ScalarfsSystemTemperatureread-onlycurrentReturn the temperature of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.17ScalarfsSystemElectricalSourceNumread-onlycurrentReturn the electrical source number of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.18TablefsSystemElectricalSourceIsNormalTablenot-accessiblecurrentA table of electrical source entries. Each object displays whether different electrical sources are normal or not.
1.3.6.1.4.1.52642.1.1.10.2.1.1.18.1RowfsSystemElectricalSourceIsNormalEntrynot-accessiblecurrentAn entry displays whether different electrical sources are normal or not.
1.3.6.1.4.1.52642.1.1.10.2.1.1.18.1.1ColumnfsSystemElectricalSourceIsNormalIndexread-onlycurrentAn index that uniquely represents a electrical source.
1.3.6.1.4.1.52642.1.1.10.2.1.1.18.1.2ColumnfsSystemElectricalSourceIsNormalread-onlycurrentThis object displays whether an electrical source is normal or not.
1.3.6.1.4.1.52642.1.1.10.2.1.1.18.1.3ColumnfsSystemElectricalSourceNameread-onlycurrentThe name of electrical source
1.3.6.1.4.1.52642.1.1.10.2.1.1.19ScalarfsSystemCurrentVoltageread-onlycurrentReturn the current voltage of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.20ScalarfsSystemFanNUMread-onlycurrentReturn the number of fan on the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.21TablefsSystemFanIsNormalTablenot-accessiblecurrentA table of fan entries. Each object displays whether different fans are normal or not.
1.3.6.1.4.1.52642.1.1.10.2.1.1.21.1RowfsSystemFanIsNormalEntrynot-accessiblecurrentAn entry displays whether different fans are normal or not.
1.3.6.1.4.1.52642.1.1.10.2.1.1.21.1.1ColumnfsSystemFanIsNormalIndexread-onlycurrentAn index that uniquely represents a fan.
1.3.6.1.4.1.52642.1.1.10.2.1.1.21.1.2ColumnfsSystemFanIsNormalread-onlycurrentThis object displays whether an fan is normal or not.
1.3.6.1.4.1.52642.1.1.10.2.1.1.21.1.3ColumnfsSystemFanNameread-onlycurrentThe name of fan
1.3.6.1.4.1.52642.1.1.10.2.1.1.21.1.4ColumnfsSystemFanSpeedread-onlycurrentThis object displays the fan's speed.
1.3.6.1.4.1.52642.1.1.10.2.1.1.22ScalarfsSystemReloadTimeRemainread-onlycurrentReturn the remain time of reloading on the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.23TablefsSystemTemperatureTablenot-accessiblecurrentA table of temperature entries. Each object displays the temperature information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.23.1RowfsSystemTemperatureEntrynot-accessiblecurrentAn entry displays the temperature information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.23.1.1ColumnfsSystemTemperatureIndexread-onlycurrentAn index that uniquely represents a device's temperature information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.23.1.2ColumnfsSystemTemperatureNameread-onlycurrentA textual name assigned to a temperature chip
1.3.6.1.4.1.52642.1.1.10.2.1.1.23.1.3ColumnfsSystemTemperatureCurrentread-onlycurrentReturn the current temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.23.1.4ColumnfsSystemTemperatureWarningVauleread-writecurrentThe first warning of temperature of the device CPU.
1.3.6.1.4.1.52642.1.1.10.2.1.1.23.1.5ColumnfsSystemTemperatureCritialVauleread-writecurrentThe second warning of temperature of the device CPU.
1.3.6.1.4.1.52642.1.1.10.2.1.1.24ScalarfsSystemSerialnoread-onlycurrentReturn the string of the serial number resides on the FastSwitch. Or return the serial number resides on the current master engine of a chassis device.
1.3.6.1.4.1.52642.1.1.10.2.1.1.25TablefsSystemVersionTablenot-accessiblecurrentA table of system version entries. Each object displays the system version information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.25.1RowfsSystemVersionEntrynot-accessiblecurrentAn entry displays the system version information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.25.1.1ColumnfsSystemVersionIndexread-onlycurrentAn index that uniquely represents a device's system version information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.25.1.2ColumnfsSystemVersionNameread-onlycurrentA textual name assigned to a system version chip
1.3.6.1.4.1.52642.1.1.10.2.1.1.25.1.3ColumnfsSystemVersionSwBootread-onlycurrentReturn the software boot system version of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.25.1.4ColumnfsSystemVersionSwCtrlread-onlycurrentReturn the software ctrl system version of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.25.1.5ColumnfsSystemVersionSwMainread-onlycurrentReturn the software main system version of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.25.1.6ColumnfsSystemVersionHwread-onlycurrentReturn the hardware system version of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.25.1.7ColumnfsSystemVersionSerialnoread-onlycurrentReturn the serial number of the FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.26ScalarfsSystemSysModelread-onlycurrentReturn the SysModel of equipment.
1.3.6.1.4.1.52642.1.1.10.2.1.1.27ScalarfsSystemUptimeread-onlycurrentReturn the SysUptime of equipment,unit is seconds.
1.3.6.1.4.1.52642.1.1.10.2.1.1.28ScalarfsSystemSampleTimeread-writecurrentSampling duration.
1.3.6.1.4.1.52642.1.1.10.2.1.1.29ScalarfsSystemStatWindowTimeread-writecurrentStating duration.
1.3.6.1.4.1.52642.1.1.10.2.1.1.30ScalarfsSystemManufacturerread-onlycurrentReturn the string of the manufacturer.
1.3.6.1.4.1.52642.1.1.10.2.1.1.31ScalarfsSystemCurrentTimeread-writecurrentReturn the current time of the system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.32ScalarfsSystemWarnResendTimeread-writecurrentReturn the resending time of warn trap of the system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.33ScalarfsSystemSoftwareNameread-onlycurrentReturn the software name of the system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.34ScalarfsSystemSoftwareManufacturerread-onlycurrentReturn the software manufacturer of the system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.35ScalarfsSystemCpuTyperead-onlycurrentReturn the cpu type infomation of the system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.36ScalarfsSystemMemoryTyperead-onlycurrentReturn the memory type of the system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.37ScalarfsSystemMemorySizeread-onlycurrentReturn the memory card storage of the system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.38ScalarfsSystemFlashSizeread-onlycurrentReturn the flash size of the system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39TablefsSystemLankApTablenot-accessiblecurrentA table of lank ap system entries. Each object displays the lank ap system information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1RowfsSystemLankApEntrynot-accessiblecurrentAn entry displays the lank ap system information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.1ColumnfsSystemLankApMacAddrread-onlycurrentAn index that uniquely represents lank ap system information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.2ColumnfsSystemLankApStatWindowTimeread-writecurrentStating duration of lank ap.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.3ColumnfsSystemLankApSampleTimeread-writecurrentSampling duration of lank ap.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.4ColumnfsSystemLankApResetread-writecurrentThis Object allow perform soft reset of lank ap system by setting its value to none zero. if a soft resetis performed, after this having completed a warm start…
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.5ColumnfsSystemLankApSoftwareNameread-onlycurrentReturn the software name of the lank ap system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.6ColumnfsSystemLankApSwVersionread-onlycurrentReturn the string of the Revision number of software resides on the lank ap FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.7ColumnfsSystemLankApSoftwareManufacturerread-onlycurrentReturn the software manufacturer of the lank ap system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.8ColumnfsSystemLankApCpuTyperead-onlycurrentReturn the cpu type infomation of the lank ap system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.9ColumnfsSystemLankApMemoryTyperead-onlycurrentReturn the memory type of the lank ap system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.10ColumnfsSystemLankApMemorySizeread-onlycurrentReturn the memory card storage of the lank ap system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.11ColumnfsSystemLankAPFlashSizeread-onlycurrentReturn the flash size of the lank ap system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.12ColumnfsSystemLankApManufacturerread-onlycurrentReturn the string of the manufacturer of lank ap.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.13ColumnfsSystemLankApSerialnoread-onlycurrentReturn the string of the serial number resides on the lank ap FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.14ColumnfsSystemLankApSysModelread-onlycurrentReturn the SysModel of lank ap equipment.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.15ColumnfsSystemLankApUptimeread-onlycurrentReturn the SysUptime of lank ap equipment.
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.16ColumnfsSystemLankApAccurateUptimeread-onlycurrentReturn the accurate system Uptime of ap equipment,unit is ticks
1.3.6.1.4.1.52642.1.1.10.2.1.1.39.1.17ColumnfsSystemLankApHwVersionread-onlycurrentReturn the string of the Revision number of hardware resides on the lank ap FastSwitch.
1.3.6.1.4.1.52642.1.1.10.2.1.1.40TablefsSystemBoardTemperatureTablenot-accessiblecurrentA table of board temperature entries. Each object displays the board temperature information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.40.1RowfsSystemBoardTemperatureEntrynot-accessiblecurrentAn entry displays the board temperature information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.40.1.1ColumnfsSystemBoardTemperatureIndexread-onlycurrentAn index that uniquely represents a device's board temperature information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.40.1.2ColumnfsSystemBoardTemperatureNameread-onlycurrentA textual name assigned to a board temperature chip
1.3.6.1.4.1.52642.1.1.10.2.1.1.40.1.3ColumnfsSystemBoardTemperatureCurrentread-onlycurrentReturn the current board temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41TablefsSystemElectricalInformationTablenot-accessiblecurrentA table of electrical entries. Each object displays the electrical information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1RowfsSystemElectricalInformationEntrynot-accessiblecurrentAn entry displays the electrical information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.1ColumnfsSystemElectricalInformationDeviceIndexread-onlycurrentAn index that uniquely represents a device.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.2ColumnfsSystemElectricalInformationIndexread-onlycurrentAn index that uniquely represents a electriacl.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.3ColumnfsSystemElectricalInformationStatusread-onlycurrentThis object displays whether an electrical source is normal or not. If the electrical is no exist, the other of electrical information maybe return nothing inf…
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.4ColumnfsSystemElectricalInformationTyperead-onlycurrentThis object displays the type of the electrical. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.5ColumnfsSystemElectricalInformationAttributeread-onlycurrentThis object displays attribute of the electrical. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.6ColumnfsSystemElectricalInformationSofeVersionread-onlycurrentThis object displays the sofe version of the electrical. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.7ColumnfsSystemElectricalInformationHardwareVersionread-onlycurrentThis object displays the hardware version of the electrical. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.8ColumnfsSystemElectricalInformationSerialread-onlycurrentThis object displays the serial of the electrical. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.9ColumnfsSystemElectricalInformationProductionDateread-onlycurrentThis object displays the productiron date of the electrical. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.10ColumnfsSystemElectricalInformationRatedPowerread-onlycurrentThis object displays the rated power(Unit: W) of the electrical. If the device is no support this information, This object will return 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.11ColumnfsSystemElectricalInformationInVoltageread-onlycurrentThis object displays the input voltage(Unit: V) of the electrical. If the device is no support this information, This object will return 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.12ColumnfsSystemElectricalInformationInCurrentread-onlycurrentThis object displays the input current(Unit: mA) of the electrical. If the device is no support this information, This object will return 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.13ColumnfsSystemElectricalInformationOutVoltageread-onlycurrentThis object displays the output voltage(Unit: V) of the electrical. If the device is no support this information, This object will return 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.14ColumnfsSystemElectricalInformationOutCurrentread-onlycurrentThis object displays the output current(Unit: mA) of the electrical. If the device is no support this information, This object will return 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.15ColumnfsSystemElectricalInformationOutPowerread-onlycurrentThis object displays the output power(Unit: W) of the electrical. If the device is no support this information, This object will return 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.16ColumnfsSystemElectricalInformationTemperatureread-onlycurrentThis object displays the temperature(Unit: C) of the electrical. If the device is no support this information, This object will return -255.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.17ColumnfsSystemElectricalInformationAirflowCoexistread-onlycurrentThis object displays the airflow coexist of the electrical. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.41.1.18ColumnfsSystemElectricalInformationWarningStatusread-onlycurrentThis object displays the warning status of the electrical. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42TablefsSystemFanInformationTablenot-accessiblecurrentA table of fan entries. Each object displays the fan information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1RowfsSystemFanInformationEntrynot-accessiblecurrentAn entry displays the fan information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.1ColumnfsSystemFanInformationDeviceIndexread-onlycurrentAn index that uniquely represents a device.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.2ColumnfsSystemFanInformationFanIndexread-onlycurrentAn index that uniquely represents a fan device.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.3ColumnfsSystemFanInformationStatusread-onlycurrentThis object displays whether an fan device source is exist or not. If the fan device is no exist, the other of fan information maybe return nothing information…
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.4ColumnfsSystemFanInformationTyperead-onlycurrentThis object displays the type of the fan. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.5ColumnfsSystemFanInformationAttributeread-onlycurrentThis object displays attribute of the fan. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.6ColumnfsSystemFanInformationSofeVersionread-onlycurrentThis object displays the sofe version of the fan. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.7ColumnfsSystemFanInformationFirmwareVersionread-onlycurrentThis object displays the firmware version of the fan. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.8ColumnfsSystemFanInformationHardwareVersionread-onlycurrentThis object displays the hardware version of the fan. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.9ColumnfsSystemFanInformationSerialread-onlycurrentThis object displays the serial of the fan. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.10ColumnfsSystemFanInformationProductionDateread-onlycurrentThis object displays the productiron date of the fan. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.11ColumnfsSystemFanInformationTemperatureread-onlycurrentThis object displays the temperature of the fan device. If the device is no support this information, This object will return -255.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.12ColumnfsSystemFanInformationNumberread-onlycurrentThis object displays the number of the fan device. If the device is no support this information, This object will return 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.13ColumnfsSystemFanInformationAirflowCoexistread-onlycurrentThis object displays the airflow coexist of the fan device. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.42.1.14ColumnfsSystemFanInformationWarningStatusread-onlycurrentThis object displays the warning status of the fan device. If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.43TablefsSystemFanStatusTablenot-accessiblecurrentA table of fan status entries. Each object displays the fan status information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.43.1RowfsSystemFanStatusEntrynot-accessiblecurrentAn entry displays the fan status information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.43.1.1ColumnfsSystemFanStatusDeviceIndexread-onlycurrentAn index that uniquely represents a device.
1.3.6.1.4.1.52642.1.1.10.2.1.1.43.1.2ColumnfsSystemFanStatusFanIndexread-onlycurrentAn index that uniquely represents a fan device.
1.3.6.1.4.1.52642.1.1.10.2.1.1.43.1.3ColumnfsSystemFanStatusIndexread-onlycurrentAn index that uniquely represents a fan.
1.3.6.1.4.1.52642.1.1.10.2.1.1.43.1.4ColumnfsSystemFanStatusread-onlycurrentThis object displays whether an fan is normal or not.
1.3.6.1.4.1.52642.1.1.10.2.1.1.43.1.5ColumnfsSystemFanStatusLevelread-onlycurrentThis object displays the level of the fan speed. If the device is no support this information, This object will return 0.
1.3.6.1.4.1.52642.1.1.10.2.1.1.43.1.6ColumnfsSystemFanStatusSpeedread-onlycurrentThis object displays fan speed(rpm). If the device is no support this information, This object will return nothing information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.44TablefsSystemMultipleTemperatureTablenot-accessiblecurrentA table of multiple temperature entries. Each object displays the multiple temperature information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.44.1RowfsSystemMultipleTemperatureEntrynot-accessiblecurrentAn entry displays the multiple temperature information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.44.1.1ColumnfsSystemMultipleTemperatureDeviceIndexread-onlycurrentAn index that uniquely represents a device.
1.3.6.1.4.1.52642.1.1.10.2.1.1.44.1.2ColumnfsSystemMultipleTemperatureSlotIndexread-onlycurrentAn index that uniquely represents a slot device.
1.3.6.1.4.1.52642.1.1.10.2.1.1.44.1.3ColumnfsSystemMultipleTemperatureIndexread-onlycurrentAn index that uniquely represents a device's multiple temperature information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.44.1.4ColumnfsSystemMultipleTemperatureNameread-onlycurrentA textual name assigned to a multiple temperature chip
1.3.6.1.4.1.52642.1.1.10.2.1.1.44.1.5ColumnfsSystemMultipleTemperatureCurrentread-onlycurrentReturn the current multiple temperature of the FastSwitch.The temperature display is not supported for the current temperature returns to -255.
1.3.6.1.4.1.52642.1.1.10.2.1.1.44.1.6ColumnfsSystemMultipleTemperatureWarningread-writecurrentReturn the warning multiple temperature of the FastSwitch.The temperature display is not supported for the warning temperature returns to -255.
1.3.6.1.4.1.52642.1.1.10.2.1.1.44.1.7ColumnfsSystemMultipleTemperatureCriticalread-writecurrentReturn the critical multiple temperature of the FastSwitch.The temperature display is not supported for the critical temperature returns to -255.
1.3.6.1.4.1.52642.1.1.10.2.1.1.45ScalarfsSystemAccurateUptimeread-onlycurrentReturn the accurate system Uptime of equipment,unit is ticks.
1.3.6.1.4.1.52642.1.1.10.2.1.1.46ScalarfsSystemPowerIndexread-onlycurrentIndex of power
1.3.6.1.4.1.52642.1.1.10.2.1.1.47ScalarfsSystemSwitchIDread-onlycurrentSwitch id in VSU
1.3.6.1.4.1.52642.1.1.10.2.1.1.48TablefsSystemApDeviceDescriptionTablenot-accessiblecurrentA table of lank ap system entries. Each object displays the lank ap system information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.48.1RowfsSystemApDeviceDescriptionEntrynot-accessiblecurrentAn entry displays the ap Device Description.
1.3.6.1.4.1.52642.1.1.10.2.1.1.48.1.1ColumnfsSystemApDescMacAddrread-onlycurrentAn index that uniquely represents ap system information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.48.1.2ColumnfsSystemApMemoryTyperead-onlycurrentReturn the memory type of the lank ap system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.48.1.3ColumnfsSystemApMemorySizeread-onlycurrentReturn the memory card storage of the lank ap system, unit is MB.
1.3.6.1.4.1.52642.1.1.10.2.1.1.48.1.4ColumnfsSystemAPFlashTyperead-onlycurrentAn index that uniquely represents ap system information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.48.1.5ColumnfsSystemAPFlashSizeread-onlycurrentReturn the flash size of the lank ap system, unit is MB.
1.3.6.1.4.1.52642.1.1.10.2.1.1.48.1.6ColumnfsSystemApNVRAMSizeread-onlycurrentReturn the NVRAM size of the lank ap system, unit is MB.
1.3.6.1.4.1.52642.1.1.10.2.1.1.48.1.7ColumnfsSystemApCFSizeread-onlycurrentReturn the CF size of the lank ap system, unit is MB.
1.3.6.1.4.1.52642.1.1.10.2.1.1.48.1.8ColumnfsSystemApCPUTyperead-onlycurrentReturn the cpu type of the lank ap system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49TablefsSystemApDeviceStatisticsTablenot-accessiblecurrentA table of lank ap system entries. Each object displays the lank ap system information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1RowfsSystemApDeviceStatisticsEntrynot-accessiblecurrentAn entry displays the ap Device Statistics.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1.1ColumnfsSystemApStatMacAddrread-onlycurrentAn index that uniquely represents ap system information.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1.2ColumnfsSystemApInterfaceNumread-onlycurrentReturn the interface number of the lank ap system.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1.3ColumnfsSystemApUptimeread-onlycurrentReturn the SysUptime of lank ap equipment, unit is ticks.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1.4ColumnfsSystemApCPUUtilizationCurrentread-onlycurrentThis is the collection of current lank ap cpu using rate.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1.5ColumnfsSystemApCPUUtilizationAverageread-onlycurrentThis is the average cpu using rate currently.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1.6ColumnfsSystemApMemoryPoolCurrentUtilizationread-onlycurrentThis is the memory pool utilization currently.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1.7ColumnfsSystemApMemoryPoolAverageUtilizationread-onlycurrentThis is the average memory pool utilization currently.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1.8ColumnfsSystemApFlashFreeSizeread-onlycurrentThis is the free size of the flash device, unit is MB.
1.3.6.1.4.1.52642.1.1.10.2.1.1.49.1.9ColumnfsSystemAPDeviceTemperatureread-onlycurrentThis is the temperature of the ap.But the ap is no support this information, so it will return 35 in perpetuity
1.3.6.1.4.1.52642.1.1.10.2.1.1.50ScalarfsSystemUptimeMsLowread-onlycurrentReturn the equipment SysUptime Low 32-bit,unit is tick.
1.3.6.1.4.1.52642.1.1.10.2.1.1.51ScalarfsSystemUptimeMsHighread-onlycurrentReturn the equipment SysUptime High 32-bit,unit is tick.
1.3.6.1.4.1.52642.1.1.10.2.1.1.52TablefsSystemFanSNTablenot-accessiblecurrentA table of fan's serial number
1.3.6.1.4.1.52642.1.1.10.2.1.1.52.1RowfsSystemFanSNEntrynot-accessiblecurrentAn entry displays fan SN.
1.3.6.1.4.1.52642.1.1.10.2.1.1.52.1.1ColumnfsSystemFanPadIndexread-onlycurrentReturn the index of the fan pad.
1.3.6.1.4.1.52642.1.1.10.2.1.1.52.1.2ColumnfsSystemFanPadNameread-onlycurrentReturn the name of the fan pad.
1.3.6.1.4.1.52642.1.1.10.2.1.1.52.1.3ColumnfsSystemFanPadSNread-onlycurrentReturn the SN of the fan pad.
1.3.6.1.4.1.52642.1.1.10.2.1.1.53TablefsSystemDsfSNTablenot-accessiblecurrentA table of dsf's serial number
1.3.6.1.4.1.52642.1.1.10.2.1.1.53.1RowfsSystemDsfSNEntrynot-accessiblecurrentAn entry displays dsf SN.
1.3.6.1.4.1.52642.1.1.10.2.1.1.53.1.1ColumnfsSystemDsfIndexread-onlycurrentReturn the index of the dsf.
1.3.6.1.4.1.52642.1.1.10.2.1.1.53.1.2ColumnfsSystemDsfNameread-onlycurrentReturn the name of the dsf.
1.3.6.1.4.1.52642.1.1.10.2.1.1.53.1.3ColumnfsSystemDsfSNread-onlycurrentReturn the SN of the dsf.
1.3.6.1.4.1.52642.1.1.10.2.1.1.54TablefsSystemPowerSNTablenot-accessiblecurrentA table of power's serial number
1.3.6.1.4.1.52642.1.1.10.2.1.1.54.1RowfsSystemPowerSNEntrynot-accessiblecurrentAn entry displays power SN.
1.3.6.1.4.1.52642.1.1.10.2.1.1.54.1.1ColumnfsSystemPowerSNIndexread-onlycurrentReturn the index of the power.
1.3.6.1.4.1.52642.1.1.10.2.1.1.54.1.2ColumnfsSystemPowerSNNameread-onlycurrentReturn the name of the power.
1.3.6.1.4.1.52642.1.1.10.2.1.1.54.1.3ColumnfsSystemPowerSNread-onlycurrentReturn the SN of the power.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55TablefsSystemFanPad1SpeedTablenot-accessiblecurrentA table of fan's speed on fan pad1.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1RowfsSystemFanPad1SpeedEntrynot-accessiblecurrentAn entry displays fan's speed on same fan pad
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.1ColumnfsSystemOamFanPad1Indexread-onlycurrentReturn the index of the fan pad.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.2ColumnfsSystemOamFanPad1Nameread-onlycurrentReturn the name of the fan pad.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.3ColumnfsSystemFanPad1Speed1read-onlycurrentReturn the speed of the fan1.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.4ColumnfsSystemFanPad1Speed2read-onlycurrentReturn the speed of the fan2.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.5ColumnfsSystemFanPad1Speed3read-onlycurrentReturn the speed of the fan3.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.6ColumnfsSystemFanPad1Speed4read-onlycurrentReturn the speed of the fan4.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.7ColumnfsSystemFanPad1Speed5read-onlycurrentReturn the speed of the fan5.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.8ColumnfsSystemFanPad1Speed6read-onlycurrentReturn the speed of the fan6.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.9ColumnfsSystemFanPad1Speed7read-onlycurrentReturn the speed of the fan7.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.10ColumnfsSystemFanPad1Speed8read-onlycurrentReturn the speed of the fan8.
1.3.6.1.4.1.52642.1.1.10.2.1.1.55.1.11ColumnfsSystemFanPad1Speed9read-onlycurrentReturn the speed of the fan9.
1.3.6.1.4.1.52642.1.1.10.2.1.1.56TablefsSystemFanPad2SpeedTablenot-accessiblecurrentA table of fan's speed on fan pad2.
1.3.6.1.4.1.52642.1.1.10.2.1.1.56.1RowfsSystemFanPad2SpeedEntrynot-accessiblecurrentAn entry displays fan's speed on same fan pad2
1.3.6.1.4.1.52642.1.1.10.2.1.1.56.1.1ColumnfsSystemOamFanPad2Indexread-onlycurrentReturn the index of the fan pad2.
1.3.6.1.4.1.52642.1.1.10.2.1.1.56.1.2ColumnfsSystemOamFanPad2Nameread-onlycurrentReturn the name of the fan pad.
1.3.6.1.4.1.52642.1.1.10.2.1.1.56.1.3ColumnfsSystemFanPad2Speed1read-onlycurrentReturn the speed of the fan1.
1.3.6.1.4.1.52642.1.1.10.2.1.1.56.1.4ColumnfsSystemFanPad2Speed2read-onlycurrentReturn the speed of the fan2.
1.3.6.1.4.1.52642.1.1.10.2.1.1.56.1.5ColumnfsSystemFanPad2Speed3read-onlycurrentReturn the speed of the fan3.
1.3.6.1.4.1.52642.1.1.10.2.1.1.57TablefsSystemFanPad3SpeedTablenot-accessiblecurrentA table of fan's speed on fan pad3.
1.3.6.1.4.1.52642.1.1.10.2.1.1.57.1RowfsSystemFanPad3SpeedEntrynot-accessiblecurrentAn entry displays fan's speed on same fan pad3
1.3.6.1.4.1.52642.1.1.10.2.1.1.57.1.1ColumnfsSystemOamFanPad3Indexread-onlycurrentReturn the index of the fan pad3.
1.3.6.1.4.1.52642.1.1.10.2.1.1.57.1.2ColumnfsSystemOamFanPad3Nameread-onlycurrentReturn the name of the fan pad.
1.3.6.1.4.1.52642.1.1.10.2.1.1.57.1.3ColumnfsSystemFanPad3Speed1read-onlycurrentReturn the speed of the fan1.
1.3.6.1.4.1.52642.1.1.10.2.1.1.57.1.4ColumnfsSystemFanPad3Speed2read-onlycurrentReturn the speed of the fan2.
1.3.6.1.4.1.52642.1.1.10.2.1.1.57.1.5ColumnfsSystemFanPad3Speed3read-onlycurrentReturn the speed of the fan3.
1.3.6.1.4.1.52642.1.1.10.2.1.1.57.1.6ColumnfsSystemFanPad3Speed4read-onlycurrentReturn the speed of the fan4.
1.3.6.1.4.1.52642.1.1.10.2.1.1.57.1.7ColumnfsSystemFanPad3Speed5read-onlycurrentReturn the speed of the fan5.
1.3.6.1.4.1.52642.1.1.10.2.1.1.58ScalarfsSystemParamSaveErrIdxread-onlycurrentParam Save Err Idx.
1.3.6.1.4.1.52642.1.1.10.2.1.1.59ScalarfsSystemParamSaveErrMsgread-onlycurrentParam Save Err Msg.
1.3.6.1.4.1.52642.1.1.10.2.1.2NodefsSystemMIBTraps
1.3.6.1.4.1.52642.1.1.10.2.1.2.1ScalarfsSystemHardChangeDescaccessible-for-notifycurrentThe description of hard change
1.3.6.1.4.1.52642.1.1.10.2.1.2.2NotificationfsSystemHardChangeDetectedcurrentSystem hardware has changed include number of devices or number of modules or the place or type of the module is change.
1.3.6.1.4.1.52642.1.1.10.2.1.2.3NotificationfsSystemPowerStateChangecurrentwhile the state of power changed, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.1.2.4NotificationfsSystemFanStateChangecurrentwhile the state of fan changed, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.1.2.5NotificationfsSystemCPUusageTooHighTrapcurrentCPU usage Too High warning.
1.3.6.1.4.1.52642.1.1.10.2.1.2.6NotificationfsSystemCPUusageTooHighRecovTrapcurrentclear the warning of CPU usage too high and report the current CPU usage.
1.3.6.1.4.1.52642.1.1.10.2.1.2.7NotificationfsSystemTmpTooHighTrapcurrentTemperature Too High warning.
1.3.6.1.4.1.52642.1.1.10.2.1.2.8NotificationfsSystemTmpTooHighRecovTrapcurrentclear the warning of temperature too high and report the current temperature.
1.3.6.1.4.1.52642.1.1.10.2.1.2.9NotificationfsSystemMemusageTooHighTrapcurrentMemory usage too high warning.
1.3.6.1.4.1.52642.1.1.10.2.1.2.10NotificationfsSystemMemusageTooHighRecovTrapcurrentclear the warning of Memory usage too high and report the current Memory usage.
1.3.6.1.4.1.52642.1.1.10.2.1.2.11NotificationfsSystemLankApCPUusageTooHighTrapcurrentlank ap CPU usage Too High warning.
1.3.6.1.4.1.52642.1.1.10.2.1.2.12NotificationfsSystemLankApCPUusageTooHighRecovTrapcurrentclear the warning of lank ap CPU usage too high and report the current CPU usage.
1.3.6.1.4.1.52642.1.1.10.2.1.2.13NotificationfsSystemLankApMemusageTooHighTrapcurrentlank ap Memory usage too high warning.
1.3.6.1.4.1.52642.1.1.10.2.1.2.14NotificationfsSystemLankApMemusageTooHighRecovTrapcurrentclear the warning of lank ap Memory usage too high and report the current Memory usage.
1.3.6.1.4.1.52642.1.1.10.2.1.2.15NotificationfsSystemResetTrapcurrentsend a trap while system reset
1.3.6.1.4.1.52642.1.1.10.2.1.2.16NotificationfsSystemLankApResetTrapcurrentsend a trap while lank ap system reset
1.3.6.1.4.1.52642.1.1.10.2.1.2.17NotificationfsSystemPowerOnTrapcurrentsend a trap while power on.
1.3.6.1.4.1.52642.1.1.10.2.1.2.18NotificationfsSystemPowerOffTrapcurrentsend a trap while power off.
1.3.6.1.4.1.52642.1.1.10.2.1.2.19NotificationfsSystemPowerOnTrapInVSUcurrentsend a trap while power on in VSU.
1.3.6.1.4.1.52642.1.1.10.2.1.2.20NotificationfsSystemPowerOffTrapInVSUcurrentsend a trap while power off in VSU.
1.3.6.1.4.1.52642.1.1.10.2.1.2.21NotificationfsSystemTmpTableTooHighTrapcurrentTemperature Too High warning with the slot index.
1.3.6.1.4.1.52642.1.1.10.2.1.2.22NotificationfsSystemTmpTableTooHighRecovTrapcurrentclear the warning of Temperature too high with the slot index.
1.3.6.1.4.1.52642.1.1.10.2.1.2.23NotificationfsSystemTmpTableTooHighTrapVSUcurrentTemperature Too High warning with the slot index in VSU.
1.3.6.1.4.1.52642.1.1.10.2.1.2.24NotificationfsSystemTmpTableTooHighRecovTrapVSUcurrentclear the warning of Temperature too high with the slot index.
1.3.6.1.4.1.52642.1.1.10.2.1.2.25NotificationfsSystemFanTableStateChangecurrentwhile the state of fan changed, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.1.2.26NotificationfsSystemFanTableStateChangeVSUcurrentIn VSU, while the state of fan changed, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.1.2.27NotificationfsSystemParamSaveErrcurrentwhile call exec write, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.1.2.28NotificationfsSystemFanTableOncurrentwhile fan is turned on, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.1.2.29NotificationfsSystemFanTableOffcurrentwhile fan is turned off, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.1.2.30NotificationfsSystemFanTableOnVSUcurrentIn VSU, while fan is turned on, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.1.2.31NotificationfsSystemFanTableOffVSUcurrentIn VSU, while fan is turned off, then this trap will be sent.
1.3.6.1.4.1.52642.1.1.10.2.1.3NodefsSystemMIBConformance
1.3.6.1.4.1.52642.1.1.10.2.1.3.1NodefsSystemMIBCompliances
1.3.6.1.4.1.52642.1.1.10.2.1.3.1.1CompliancefsSystemMIBCompliancecurrentThe compliance statement for entities which implement the FS System MIB
1.3.6.1.4.1.52642.1.1.10.2.1.3.2NodefsSystemMIBGroups
1.3.6.1.4.1.52642.1.1.10.2.1.3.2.1GroupfsSystemMIBGroupcurrentA collection of objects providing system information and opertion to a FS agent.