MICROSENS-G6-MIBg6
SNMPv2-SMICounter32 enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString MacAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.3181.10.6.1IdentitydeviceMicrosens private MIB for Generation 6 Ethernet Switches
1.3.6.1.4.1.3181.10.6.1.31Nodehardware
1.3.6.1.4.1.3181.10.6.1.31.1ScalarhardwareLedTestread-writecurrentRuns a leds test whereby all LED light up in all possible colors for checking their function. The tests terminates within a few seconds.
1.3.6.1.4.1.3181.10.6.1.31.2ScalarhardwareLedModeread-writecurrentThe LED display can be configured to be less intrusive.
1.3.6.1.4.1.3181.10.6.1.31.3ScalarhardwarePowerSupply1Monitoredread-writecurrentWhen disabled a missing power supply 1 will not turn the associated led red on failure. Do this when single power supply 2 operation is used or when the device…
1.3.6.1.4.1.3181.10.6.1.31.4ScalarhardwarePowerSupply2Monitoredread-writecurrentWhen disabled a missing power supply 2 will not turn the associated led red on failure. Do this when single power supply 1 operation is used or when the device…
1.3.6.1.4.1.3181.10.6.1.31.5ScalarhardwareFactoryResetButtonread-writecurrentWhen disabled the factory button will trigger the factory reset function when pressed for a long time. The IP discover function upon a short button click is no…
1.3.6.1.4.1.3181.10.6.1.31.6TablecableTestConfigTablenot-accessiblecurrentThe cable tester allows for detection of copper cable faults and can even detect where the fault is located.
1.3.6.1.4.1.3181.10.6.1.31.6.1RowcableTestConfigEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.6.1.1ColumncableTestConfigPortIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.6.1.2ColumncableTestConfigEnableAutoCableTestread-writecurrentWhen enabled a cable test is performed each time the link goes down. The test is only performed for copper ports or dual media ports in copper mode.
1.3.6.1.4.1.3181.10.6.1.31.6.1.3ColumncableTestConfigEventGenerationread-writecurrentWhen the cable termination status changes an event can be raised.
1.3.6.1.4.1.3181.10.6.1.31.6.1.4ColumncableTestConfigReflectionThresholdread-writecurrentSelect a value up to 508 which is used to decide between a connected cable and a remotely disconnected cable. With actively terminated data ports, the detectio…
1.3.6.1.4.1.3181.10.6.1.31.6.1.5ColumncableTestConfigReflectionHysteresisread-writecurrentChoose value to prevent oscillation when reflection value is slightly shifting.
1.3.6.1.4.1.3181.10.6.1.31.6.1.6ColumncableTestConfigStartTestNowread-writecurrentMay be used to manually start a cable test. ATTENTION: If the port is in link up status it will be forced to link down first. This will disrupt the current dat…
1.3.6.1.4.1.3181.10.6.1.31.7TableioSignalConfigTablenot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.7.1RowioSignalConfigEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.7.1.1ColumnioSignalConfigIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.7.1.2ColumnioSignalConfigSignalModeread-writecurrentPermit setting of io signal LEDs and relays to static or blink blink mode for increased visualization.
1.3.6.1.4.1.3181.10.6.1.31.7.1.3ColumnioSignalConfigInput1Moderead-writecurrentWhen this function is activated the external alarm input 1 is monitored. Note: alarm inputs are not available in all product versions.
1.3.6.1.4.1.3181.10.6.1.31.7.1.4ColumnioSignalConfigInput1Nameread-writecurrentA customer specific name can be specified for input 1. This name will appear in the associated event messages.
1.3.6.1.4.1.3181.10.6.1.31.7.1.5ColumnioSignalConfigInput2Moderead-writecurrentWhen this function is activated the external alarm input 2 is monitored. Note: alarm inputs are not available in all product versions.
1.3.6.1.4.1.3181.10.6.1.31.7.1.6ColumnioSignalConfigInput2Nameread-writecurrentA customer specific name can be specified for input 2. This name will appear in the associated event messages.
1.3.6.1.4.1.3181.10.6.1.31.7.1.7ColumnioSignalConfigOutput1Triggerread-writecurrentDefines on which condition the alarm relay 1 is activated. Note: alarm relays are not available in all product versions.
1.3.6.1.4.1.3181.10.6.1.31.7.1.8ColumnioSignalConfigOutput1Nameread-writecurrentA customer specific name can be specified for alarm output 1. This name will appear in the associated event messages.
1.3.6.1.4.1.3181.10.6.1.31.7.1.9ColumnioSignalConfigOutput2Triggerread-writecurrentDefines on which condition the alarm relay 2 is activated. Note: alarm relays are not available in all product versions.
1.3.6.1.4.1.3181.10.6.1.31.7.1.10ColumnioSignalConfigOutput2Nameread-writecurrentA customer specific name can be specified for alarm output 2. This name will appear in the associated event messages.
1.3.6.1.4.1.3181.10.6.1.31.100ScalarhardwarePowerSupply1Statusread-onlycurrentDisplays state of primary supply or only supply for single supply systems.
1.3.6.1.4.1.3181.10.6.1.31.101ScalarhardwarePowerSupply2Statusread-onlycurrentDisplays state of secondary supply if available.
1.3.6.1.4.1.3181.10.6.1.31.102ScalarhardwareRunningOnPoeread-onlycurrentWhen set the unit currently operates on the PD input via PoE.
1.3.6.1.4.1.3181.10.6.1.31.103ScalarhardwareFanStatusread-onlycurrentDisplays state of cooling fan. Indicates UNUSED in fanless devices.
1.3.6.1.4.1.3181.10.6.1.31.104ScalarhardwareSdCardStatusread-onlycurrentCurrent status of SD-card.
1.3.6.1.4.1.3181.10.6.1.31.105ScalarhardwareNumOfPortsread-onlycurrentTotal number of Ethernet ports this hardware offers.
1.3.6.1.4.1.3181.10.6.1.31.106ScalarhardwareMaskOfExistingPortsread-onlycurrentSet bit for each port that physically exisiting and could be in use.
1.3.6.1.4.1.3181.10.6.1.31.107ScalarhardwareMaskOfSfpPortsread-onlycurrentMarks which ports support SFPs.
1.3.6.1.4.1.3181.10.6.1.31.108ScalarhardwareMaskOfPoePortsread-onlycurrentMarks which ports support PoE output.
1.3.6.1.4.1.3181.10.6.1.31.109TablemoduleInfoTablenot-accessiblecurrentThis section indicates which modules are inserted in the optional extension slots.
1.3.6.1.4.1.3181.10.6.1.31.109.1RowmoduleInfoEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.109.1.1ColumnmoduleInfoIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.109.1.2ColumnmoduleInfoUnitTyperead-onlycurrentIdentfies the general type of module.
1.3.6.1.4.1.3181.10.6.1.31.109.1.3ColumnmoduleInfoArticleNumberread-onlycurrentThe article number of the module in this slot.
1.3.6.1.4.1.3181.10.6.1.31.109.1.4ColumnmoduleInfoSerialNumberread-onlycurrentThe serial number of the module in this slot.
1.3.6.1.4.1.3181.10.6.1.31.109.1.5ColumnmoduleInfoHardwareVersionread-onlycurrentThis device hardware revision number.
1.3.6.1.4.1.3181.10.6.1.31.109.1.6ColumnmoduleInfoProjectNumberread-onlycurrentMICROSENS project number.
1.3.6.1.4.1.3181.10.6.1.31.109.1.7ColumnmoduleInfoOccupiedSlotsread-onlycurrentLists all slots contained in this module.
1.3.6.1.4.1.3181.10.6.1.31.109.1.8ColumnmoduleInfoDescriptionread-onlycurrentFeature summary of the module.
1.3.6.1.4.1.3181.10.6.1.31.110TableslotInfoTablenot-accessiblecurrentThis section indicates which modules are inserted in the optional extension slots.
1.3.6.1.4.1.3181.10.6.1.31.110.1RowslotInfoEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.110.1.1ColumnslotInfoIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.110.1.2ColumnslotInfoBoardTyperead-onlycurrentGeneral type of board function
1.3.6.1.4.1.3181.10.6.1.31.110.1.3ColumnslotInfoBoardIdread-onlycurrentThis identifies the board type for internal operation.
1.3.6.1.4.1.3181.10.6.1.31.110.1.4ColumnslotInfoVersionBitsread-onlycurrentVersion bits from hardware or backplane.
1.3.6.1.4.1.3181.10.6.1.31.111TableportInfoTablenot-accessiblecurrentUsed to map physical to logical port ids.
1.3.6.1.4.1.3181.10.6.1.31.111.1RowportInfoEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.111.1.1ColumnportInfoPortIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.111.1.2ColumnportInfoSystemSlotread-onlycurrentDescribes on which system slot this port index is located.
1.3.6.1.4.1.3181.10.6.1.31.111.1.3ColumnportInfoSwitchPortread-onlycurrentDescribes on which switch port this port index is located.
1.3.6.1.4.1.3181.10.6.1.31.111.1.4ColumnportInfoUserSlotread-onlycurrentSlot number as seen by customer.
1.3.6.1.4.1.3181.10.6.1.31.111.1.5ColumnportInfoUserPortread-onlycurrentPort number as seen by customer.
1.3.6.1.4.1.3181.10.6.1.31.111.1.6ColumnportInfoSnmpPortread-onlycurrentSlot and port representation as used in SNMP. Formula is Slot*100 + Port.
1.3.6.1.4.1.3181.10.6.1.31.111.1.7ColumnportInfoSnmpInstanceread-onlycurrentPort instance counting from 0 to number of ports
1.3.6.1.4.1.3181.10.6.1.31.111.1.8ColumnportInfoHardwarePortread-onlycurrentPort number as used internally. Ports may not be in sequential order.
1.3.6.1.4.1.3181.10.6.1.31.111.1.9ColumnportInfoInterfaceTyperead-onlycurrentIdentifies port as copper or optical. Also used for snmp ifType definition
1.3.6.1.4.1.3181.10.6.1.31.111.1.10ColumnportInfoPropertiesread-onlycurrentDescribes which functions the port can support.
1.3.6.1.4.1.3181.10.6.1.31.112TableportLedsTablenot-accessiblecurrentThis section indicates the state of all port related LEDs.
1.3.6.1.4.1.3181.10.6.1.31.112.1RowportLedsEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.112.1.1ColumnportLedsPortIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.112.1.2ColumnportLedsEthernetColorread-onlycurrentEthernet Link LED.
1.3.6.1.4.1.3181.10.6.1.31.112.1.3ColumnportLedsEthernetBlinkingread-onlycurrentEthernet Link LED.
1.3.6.1.4.1.3181.10.6.1.31.112.1.4ColumnportLedsPoeColorread-onlycurrentPower over Ethernet LED. For optical ports this indicates signal detect status.
1.3.6.1.4.1.3181.10.6.1.31.112.1.5ColumnportLedsPoeBlinkingread-onlycurrentPower over Ethernet LED. For optical ports this indicates signal detect status.
1.3.6.1.4.1.3181.10.6.1.31.113TabledeviceLedsTablenot-accessiblecurrentThis section indicates the state of all LEDs which are not port related. Please note: Not every unit offers all LEDs.
1.3.6.1.4.1.3181.10.6.1.31.113.1RowdeviceLedsEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.113.1.1ColumndeviceLedsIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.113.1.2ColumndeviceLedsSystem1Colorread-onlycurrentThis status corresponds to 'sys' LED on some devices.
1.3.6.1.4.1.3181.10.6.1.31.113.1.3ColumndeviceLedsSystem1Blinkingread-onlycurrentThis status corresponds to 'sys' LED on some devices.
1.3.6.1.4.1.3181.10.6.1.31.113.1.4ColumndeviceLedsSystem2Colorread-onlycurrentDisplays external management activity.
1.3.6.1.4.1.3181.10.6.1.31.113.1.5ColumndeviceLedsSystem2Blinkingread-onlycurrentDisplays external management activity.
1.3.6.1.4.1.3181.10.6.1.31.113.1.6ColumndeviceLedsPowerOn1Colorread-onlycurrentThis status corresponds to 'on' LED on some devices.
1.3.6.1.4.1.3181.10.6.1.31.113.1.7ColumndeviceLedsPowerOn1Blinkingread-onlycurrentThis status corresponds to 'on' LED on some devices.
1.3.6.1.4.1.3181.10.6.1.31.113.1.8ColumndeviceLedsPowerOn2Colorread-onlycurrentAlternative power input LED.
1.3.6.1.4.1.3181.10.6.1.31.113.1.9ColumndeviceLedsPowerOn2Blinkingread-onlycurrentAlternative power input LED.
1.3.6.1.4.1.3181.10.6.1.31.113.1.10ColumndeviceLedsRing1Colorread-onlycurrentThis LED is used when ring protection is enabled.
1.3.6.1.4.1.3181.10.6.1.31.113.1.11ColumndeviceLedsRing1Blinkingread-onlycurrentThis LED is used when ring protection is enabled.
1.3.6.1.4.1.3181.10.6.1.31.113.1.12ColumndeviceLedsRing2Colorread-onlycurrentThis LED is used when ring protection is enabled.
1.3.6.1.4.1.3181.10.6.1.31.113.1.13ColumndeviceLedsRing2Blinkingread-onlycurrentThis LED is used when ring protection is enabled.
1.3.6.1.4.1.3181.10.6.1.31.113.1.14ColumndeviceLedsSignalIn1Colorread-onlycurrentIndicates status of alarm input 1.
1.3.6.1.4.1.3181.10.6.1.31.113.1.15ColumndeviceLedsSignalIn1Blinkingread-onlycurrentIndicates status of alarm input 1.
1.3.6.1.4.1.3181.10.6.1.31.113.1.16ColumndeviceLedsSignalIn2Colorread-onlycurrentIndicates status of alarm input 2.
1.3.6.1.4.1.3181.10.6.1.31.113.1.17ColumndeviceLedsSignalIn2Blinkingread-onlycurrentIndicates status of alarm input 2.
1.3.6.1.4.1.3181.10.6.1.31.113.1.18ColumndeviceLedsSignalOut1Colorread-onlycurrentIndicates status of alarm relay output 1.
1.3.6.1.4.1.3181.10.6.1.31.113.1.19ColumndeviceLedsSignalOut1Blinkingread-onlycurrentIndicates status of alarm relay output 1.
1.3.6.1.4.1.3181.10.6.1.31.113.1.20ColumndeviceLedsSignalOut2Colorread-onlycurrentIndicates status of alarm relay output 2.
1.3.6.1.4.1.3181.10.6.1.31.113.1.21ColumndeviceLedsSignalOut2Blinkingread-onlycurrentIndicates status of alarm relay output 2.
1.3.6.1.4.1.3181.10.6.1.31.114TablecableTestStatusTablenot-accessiblecurrentThis table display the result of the last cable test. Values are only available for copper ports while a link is down and if the cable test function is enabled.
1.3.6.1.4.1.3181.10.6.1.31.114.1RowcableTestStatusEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.114.1.1ColumncableTestStatusPortIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.114.1.2ColumncableTestStatusUpdateTimeStampread-onlycurrentIndicates the time when this record was last updated.
1.3.6.1.4.1.3181.10.6.1.31.114.1.3ColumncableTestStatusPair0Stateread-onlycurrentIndicates line termination test results for wire pair 0 (Pins 1/2)
1.3.6.1.4.1.3181.10.6.1.31.114.1.4ColumncableTestStatusPair0DistanceToFaultread-onlycurrentDistance to fault on wire pair 0 in centimeters. Indicates 0 when no fault is detected or the function is unused.
1.3.6.1.4.1.3181.10.6.1.31.114.1.5ColumncableTestStatusPair1Stateread-onlycurrentIndicates line termination test results for wire pair 1 (Pins 3/6)
1.3.6.1.4.1.3181.10.6.1.31.114.1.6ColumncableTestStatusPair1DistanceToFaultread-onlycurrentDistance to fault on wire pair 1 in centimeters. Indicates 0 when no fault is detected or the function is unused.
1.3.6.1.4.1.3181.10.6.1.31.114.1.7ColumncableTestStatusPair2Stateread-onlycurrentIndicates line termination test results for wire pair 2 (Pins 4/5)
1.3.6.1.4.1.3181.10.6.1.31.114.1.8ColumncableTestStatusPair2DistanceToFaultread-onlycurrentDistance to fault on wire pair 2 in centimeters. Indicates 0 when no fault is detected or the function is unused.
1.3.6.1.4.1.3181.10.6.1.31.114.1.9ColumncableTestStatusPair3Stateread-onlycurrentIndicates line termination test results for wire pair 3 (Pins 7/8)
1.3.6.1.4.1.3181.10.6.1.31.114.1.10ColumncableTestStatusPair3DistanceToFaultread-onlycurrentDistance to fault on wire pair 3 in centimeters. Indicates 0 when no fault is detected or the function is unused.
1.3.6.1.4.1.3181.10.6.1.31.114.1.11ColumncableTestStatusReflectionValueread-onlycurrentA unitless value that indicates a measure of reflection level. For difficult to detect actively terminated devices perform a measurement with remotely plugged-…
1.3.6.1.4.1.3181.10.6.1.31.114.1.12ColumncableTestStatusCableStatusread-onlycurrentIndicates the concluded status summary.
1.3.6.1.4.1.3181.10.6.1.31.115TableioSignalStatusTablenot-accessiblecurrentThis section is only used for devices which offer external signal inputs and outputs.
1.3.6.1.4.1.3181.10.6.1.31.115.1RowioSignalStatusEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.115.1.1ColumnioSignalStatusIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.115.1.2ColumnioSignalStatusInput1AlarmActiveread-onlycurrentIndicates true when the input 1 is logically active.
1.3.6.1.4.1.3181.10.6.1.31.115.1.3ColumnioSignalStatusInput2AlarmActiveread-onlycurrentIndicates true when the input 2 is logically active.
1.3.6.1.4.1.3181.10.6.1.31.115.1.4ColumnioSignalStatusOutput1RelayActiveread-onlycurrentIndicates true when the output 1 relay is activated.
1.3.6.1.4.1.3181.10.6.1.31.115.1.5ColumnioSignalStatusOutput2RelayActiveread-onlycurrentIndicates true when the output 2 relay is activated.
1.3.6.1.4.1.3181.10.6.1.31.116TabletcamStatusTablenot-accessiblecurrentThe TCAM is a programmable wire speed packet filter. The filter is controlled by the system automatically. This table indicates which filters have been set.
1.3.6.1.4.1.3181.10.6.1.31.116.1RowtcamStatusEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.31.116.1.1ColumntcamStatusIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.31.116.1.2ColumntcamStatusControlFileread-onlycurrentReflects the name of the control file associated with this tcam entry.
1.3.6.1.4.1.3181.10.6.1.31.116.1.3ColumntcamStatusDescriptionread-onlycurrentDescriptive text what explains what this tcam entry will do.