MIB Viewer

G6-NTP-MIB

22 objects
Microsens private MIB for Generation 6 Ethernet Switches
Imported Objects
MICROSENS-G6-MIBg6
SNMPv2-SMICounter32 enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString MacAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.3181.10.6.3IdentitymanagementMicrosens private MIB for Generation 6 Ethernet Switches
1.3.6.1.4.1.3181.10.6.3.73Nodentp
1.3.6.1.4.1.3181.10.6.3.73.1ScalarntpEnableNtpread-writecurrentWhen enabled the local clock will be synchronized with the time provided by a time server.
1.3.6.1.4.1.3181.10.6.3.73.2ScalarntpSyncNowread-writecurrentAction command to read time server now and setup the internal clock.
1.3.6.1.4.1.3181.10.6.3.73.3ScalarntpDhcpProvidesNtpServerread-writecurrentEnable DHCP to automatically retrieve NTP server address(es). When disabled, the locally defined addresses are used instead.
1.3.6.1.4.1.3181.10.6.3.73.4ScalarntpMainNtpServerread-writecurrentThis is the preferred NTP server address. IP address or symbolic name may be used.
1.3.6.1.4.1.3181.10.6.3.73.5ScalarntpBackupNtpServerread-writecurrentThis defines an optional alternate ntp server address. IP address or symbolic name may be used.
1.3.6.1.4.1.3181.10.6.3.73.6ScalarntpTrustedServerread-writecurrentSome NTP server (Windows) indicate a too large deviation or indicate they are unreliable when they are not externally synchronized. To be able to still use suc…
1.3.6.1.4.1.3181.10.6.3.73.7ScalarntpSyncIntervalread-writecurrentResynchronization interval (minutes), default once per day.
1.3.6.1.4.1.3181.10.6.3.73.8ScalarntpShowTimeDateread-writecurrentShow system time and date.
1.3.6.1.4.1.3181.10.6.3.73.9ScalarntpListTimeZonesread-writecurrentDisplays a long list of available timezones. Pick the timezone that matches your location and use this name for the time_zone parameter.
1.3.6.1.4.1.3181.10.6.3.73.10ScalarntpTimeZoneread-writecurrentEnter a string exactly as obtained via list_time_zones command. Note that a change of the time zone if only effective after a system reboot.
1.3.6.1.4.1.3181.10.6.3.73.11ScalarntpTimeFormatread-writecurrentThis parameter permits definition of the time format displayed under ntp.local_time. When left blank the default format hrs:min:sec is used. The parameter foll…
1.3.6.1.4.1.3181.10.6.3.73.12ScalarntpDateFormatread-writecurrentThis parameter permits definition of the data format displayed under ntp.local_date. When left blank the default format year-month-date is used. The parameter …
1.3.6.1.4.1.3181.10.6.3.73.100ScalarntpStatusread-onlycurrentIndicates by which means the clock was last set.
1.3.6.1.4.1.3181.10.6.3.73.101ScalarntpLocalTimeread-onlycurrentDisplays the current local date according to selected time zone in the format defined user ntp.time_format.
1.3.6.1.4.1.3181.10.6.3.73.102ScalarntpLocalDateread-onlycurrentDisplays the current local date according to selected time zone in the format defined user ntp.date_format.
1.3.6.1.4.1.3181.10.6.3.73.103ScalarntpUsedNtpServerread-onlycurrentActually used ntp server IP address or name
1.3.6.1.4.1.3181.10.6.3.73.104ScalarntpDynamicNtpServer1read-onlycurrentMain dynamically assigned ntp server IP address.
1.3.6.1.4.1.3181.10.6.3.73.105ScalarntpDynamicNtpServer2read-onlycurrentAlternate dynamically assigned ntp server IP address.
1.3.6.1.4.1.3181.10.6.3.73.106ScalarntpDynamicNtpServer3read-onlycurrentAlternate dynamically assigned ntp server IP address.
1.3.6.1.4.1.3181.10.6.3.73.107ScalarntpDynamicNtpServer4read-onlycurrentAlternate dynamically assigned ntp server IP address.