G6-POE-MIB
31 objects
Microsens private MIB for Generation 6 Ethernet Switches
Imported Objects
| MICROSENS-G6-MIB | g6 |
| SNMPv2-SMI | Counter32 enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString MacAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3181.10.6.1 | Identitydevice | Microsens private MIB for Generation 6 Ethernet Switches | ||
| 1.3.6.1.4.1.3181.10.6.1.33 | Nodepoe | |||
| 1.3.6.1.4.1.3181.10.6.1.33.1 | ScalarpoePoeMaxPowerAvailable | read-write | current | Defines the total power that this units power supply can support. This value is used to balance the PoE output power delivered. Please adjust according to conn… |
| 1.3.6.1.4.1.3181.10.6.1.33.2 | ScalarpoeRestartPoePort | read-write | current | This function may be used to briefly drop the power on a PoE port in order to reboot the attached device. Please supply port number as parameter. The shorthand… |
| 1.3.6.1.4.1.3181.10.6.1.33.3 | TableconfigTable | not-accessible | current | Power over Ethernet function permits the powering of connected units which do not use their own local power supply. |
| 1.3.6.1.4.1.3181.10.6.1.33.3.1 | RowconfigEntry | not-accessible | current | |
| 1.3.6.1.4.1.3181.10.6.1.33.3.1.1 | ColumnconfigPortIndex | not-accessible | current | Automatically generated |
| 1.3.6.1.4.1.3181.10.6.1.33.3.1.2 | ColumnconfigMode | read-write | current | Used to enable or disable PoE function. |
| 1.3.6.1.4.1.3181.10.6.1.33.3.1.3 | ColumnconfigPriorityPort | read-write | current | Ports without priority may be switched off under a power contention situation. |
| 1.3.6.1.4.1.3181.10.6.1.33.3.1.4 | ColumnconfigEnablePoePlus | read-write | current | Allow between 15-30W power consumption. |
| 1.3.6.1.4.1.3181.10.6.1.33.100 | ScalarpoeTotalPowerConsumed | read-only | current | The sum of power currently delivered to all ports. (units: mW) |
| 1.3.6.1.4.1.3181.10.6.1.33.101 | TablestatusTable | not-accessible | current | This table list the current PoE port conditions. |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1 | RowstatusEntry | not-accessible | current | |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1.1 | ColumnstatusPortIndex | not-accessible | current | Automatically generated |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1.2 | ColumnstatusCondition | read-only | current | PoE status and conditions. |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1.3 | ColumnstatusDeterminedClass | read-only | current | Determined and negotiated PoE class. |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1.4 | ColumnstatusOutputCurrent | read-only | current | Current delivered to the attached device. (units: mA) |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1.5 | ColumnstatusOutputVoltage | read-only | current | Voltage deliverd to the attached device. (units: mV) |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1.6 | ColumnstatusOutputPower | read-only | current | Calculated power delivered to the attached device. (units: mW) |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1.7 | ColumnstatusPowerDeniedCounter | read-only | current | Incremented whenever a PoE request was denied regardless of reason. |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1.8 | ColumnstatusOverCurrentCounter | read-only | current | Incremented whenever an over_current condition was detected. |
| 1.3.6.1.4.1.3181.10.6.1.33.101.1.9 | ColumnstatusShortCircuitCounter | read-only | current | Incremented whenever a short circuit was detected. |
| 1.3.6.1.4.1.3181.10.6.1.33.102 | TableenergySuppliedTable | not-accessible | current | This table list the power provided via PoE ports. The values are automatically updated in the given interval. |
| 1.3.6.1.4.1.3181.10.6.1.33.102.1 | RowenergySuppliedEntry | not-accessible | current | |
| 1.3.6.1.4.1.3181.10.6.1.33.102.1.1 | ColumnenergySuppliedPortIndex | not-accessible | current | Automatically generated |
| 1.3.6.1.4.1.3181.10.6.1.33.102.1.2 | ColumnenergySuppliedLast5Seconds | read-only | current | Energy supplied in the past 5 seconds. Value in joule. |
| 1.3.6.1.4.1.3181.10.6.1.33.102.1.3 | ColumnenergySuppliedLast15Seconds | read-only | current | Energy supplied in the past 15 seconds. Value in joule. |
| 1.3.6.1.4.1.3181.10.6.1.33.102.1.4 | ColumnenergySuppliedLastMinute | read-only | current | Energy supplied in the past 60 seconds. Value in joule. |
| 1.3.6.1.4.1.3181.10.6.1.33.102.1.5 | ColumnenergySuppliedLast15Minutes | read-only | current | Energy supplied in the past 15 minutes. Value in joule. |
| 1.3.6.1.4.1.3181.10.6.1.33.102.1.6 | ColumnenergySuppliedLastHour | read-only | current | Energy supplied in the past hour. Value in joule. |
| 1.3.6.1.4.1.3181.10.6.1.33.102.1.7 | ColumnenergySuppliedLastDay | read-only | current | Energy supplied in the past day. Value in joule. |