Microsens private MIB for Generation 6 Ethernet Switches
Imported Objects
MICROSENS-G6-MIBg6
SNMPv2-SMICounter32 enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString MacAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.3181.10.6.1IdentitydeviceMicrosens private MIB for Generation 6 Ethernet Switches
1.3.6.1.4.1.3181.10.6.1.34Nodesfp
1.3.6.1.4.1.3181.10.6.1.34.1TableconfigTablenot-accessiblecurrentThese setting apply to each SFP in the system.
1.3.6.1.4.1.3181.10.6.1.34.1.1RowconfigEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.34.1.1.1ColumnconfigIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.34.1.1.2ColumnconfigLossOfSignalEventread-writecurrentWhen enabled a loss of optical signal or the return of the signal will create an event.
1.3.6.1.4.1.3181.10.6.1.34.1.1.3ColumnconfigOpticalDeltaDetectread-writecurrentAn optical receive power level change of more than delta_threshold between two successive read cycles generates an event.
1.3.6.1.4.1.3181.10.6.1.34.1.1.4ColumnconfigDeltaThresholdread-writecurrentDefines the dB difference required to trigger an event. Only 1 dB steps are permitted. A value of 0 detects any change. This setting is only for testing. Recom…
1.3.6.1.4.1.3181.10.6.1.34.100TableinformationTablenot-accessiblecurrentThis table displays data which are read from the inserted SFPs.
1.3.6.1.4.1.3181.10.6.1.34.100.1RowinformationEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.1.34.100.1.1ColumninformationPortIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.1.34.100.1.2ColumninformationPortread-onlycurrentIndicates the physical port in which this SFP is inserted.
1.3.6.1.4.1.3181.10.6.1.34.100.1.3ColumninformationLocationread-onlycurrentTextual description of SFP location.
1.3.6.1.4.1.3181.10.6.1.34.100.1.4ColumninformationStatusread-onlycurrentShould indicate OK. LOSS_OF_SIGNAL is shown when the optical receive power level is below the critical lower limit.
1.3.6.1.4.1.3181.10.6.1.34.100.1.5ColumninformationTyperead-onlycurrentThis parameter shows which type of optics are installed
1.3.6.1.4.1.3181.10.6.1.34.100.1.6ColumninformationConnectorread-onlycurrentShows which connector is used with this SFP.
1.3.6.1.4.1.3181.10.6.1.34.100.1.7ColumninformationWavelengthread-onlycurrentNominal wavelength if this SFP. May also indicate ITU channel for DWDM optics.
1.3.6.1.4.1.3181.10.6.1.34.100.1.8ColumninformationTxTechnologyread-onlycurrentDistinguishes between multimode and single mode SFP. For DWDM SFP more details including grid are shown.
1.3.6.1.4.1.3181.10.6.1.34.100.1.9ColumninformationRxTechnologyread-onlycurrentDistinguishes between normal PIN receivers and more sensitive APD receivers.
1.3.6.1.4.1.3181.10.6.1.34.100.1.10ColumninformationNominalBitrateread-onlycurrentNominal bitrate rounded to nearest 100Mbit. Usually the SFP can be operated at lower speed as well.
1.3.6.1.4.1.3181.10.6.1.34.100.1.11ColumninformationManufacturerread-onlycurrentShows the manufacturer of this SFP.
1.3.6.1.4.1.3181.10.6.1.34.100.1.12ColumninformationPartNumberread-onlycurrentShows the part number of this SFP. This will differ from the MICROSENS order code unless also MICROSENS is indicated as manufacturer.
1.3.6.1.4.1.3181.10.6.1.34.100.1.13ColumninformationRevisionread-onlycurrentInternal revision code of this SFP.
1.3.6.1.4.1.3181.10.6.1.34.100.1.14ColumninformationSerialNumberread-onlycurrentSerial number of the SFP.
1.3.6.1.4.1.3181.10.6.1.34.100.1.15ColumninformationMfgDateCoderead-onlycurrentManufacturing date code.
1.3.6.1.4.1.3181.10.6.1.34.100.1.16ColumninformationWarningsread-onlycurrent
1.3.6.1.4.1.3181.10.6.1.34.100.1.17ColumninformationAlarmsread-onlycurrent
1.3.6.1.4.1.3181.10.6.1.34.100.1.18ColumninformationTxPowerread-onlycurrentIndicates the optical output in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.
1.3.6.1.4.1.3181.10.6.1.34.100.1.19ColumninformationRxPowerread-onlycurrentIndicates the optical input in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown.
1.3.6.1.4.1.3181.10.6.1.34.100.1.20ColumninformationTemperatureread-onlycurrentDisplays the temperature inside the SFP. This is usually higher than the system temperature.
1.3.6.1.4.1.3181.10.6.1.34.100.1.21ColumninformationMaxLength9Umread-onlycurrentDisplays nominal maximum reach of this SFP on a standard single mode fiber.
1.3.6.1.4.1.3181.10.6.1.34.100.1.22ColumninformationMaxLength50Umread-onlycurrentDisplays nominal maximum reach of this SFP on a 50 micro meter multimode fiber.
1.3.6.1.4.1.3181.10.6.1.34.100.1.23ColumninformationMaxLength62Umread-onlycurrentDisplays nominal maximum reach of this SFP on a 62.5 micro meter multimode fiber.
1.3.6.1.4.1.3181.10.6.1.34.100.1.24ColumninformationMaxLengthCopperread-onlycurrentDisplays nominal maximum reach of this SFP on a copper cable. Only applies to electrical SFP.
1.3.6.1.4.1.3181.10.6.1.34.100.1.25ColumninformationTuningRangeread-onlycurrentFor wavelength tunable optics additional details are shown here.
1.3.6.1.4.1.3181.10.6.1.34.100.1.26ColumninformationPowerConsumptionread-onlycurrentTypcial power consumption values are shown if available from the interface.
1.3.6.1.4.1.3181.10.6.1.34.100.1.27ColumninformationAdditionalInformationread-onlycurrentSome special SFP can supply additional measurement data. For example OTDR reflection data can be listed here.