G6-SFP-MIB
37 objects
Microsens private MIB for Generation 6 Ethernet Switches
Imported Objects
| MICROSENS-G6-MIB | g6 |
| SNMPv2-SMI | Counter32 enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString MacAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3181.10.6.1 | Identitydevice | Microsens private MIB for Generation 6 Ethernet Switches | ||
| 1.3.6.1.4.1.3181.10.6.1.34 | Nodesfp | |||
| 1.3.6.1.4.1.3181.10.6.1.34.1 | TableconfigTable | not-accessible | current | These setting apply to each SFP in the system. |
| 1.3.6.1.4.1.3181.10.6.1.34.1.1 | RowconfigEntry | not-accessible | current | |
| 1.3.6.1.4.1.3181.10.6.1.34.1.1.1 | ColumnconfigIndex | not-accessible | current | Automatically generated |
| 1.3.6.1.4.1.3181.10.6.1.34.1.1.2 | ColumnconfigLossOfSignalEvent | read-write | current | When enabled a loss of optical signal or the return of the signal will create an event. |
| 1.3.6.1.4.1.3181.10.6.1.34.1.1.3 | ColumnconfigOpticalDeltaDetect | read-write | current | An optical receive power level change of more than delta_threshold between two successive read cycles generates an event. |
| 1.3.6.1.4.1.3181.10.6.1.34.1.1.4 | ColumnconfigDeltaThreshold | read-write | current | Defines the dB difference required to trigger an event. Only 1 dB steps are permitted. A value of 0 detects any change. This setting is only for testing. Recom… |
| 1.3.6.1.4.1.3181.10.6.1.34.100 | TableinformationTable | not-accessible | current | This table displays data which are read from the inserted SFPs. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1 | RowinformationEntry | not-accessible | current | |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.1 | ColumninformationPortIndex | not-accessible | current | Automatically generated |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.2 | ColumninformationPort | read-only | current | Indicates the physical port in which this SFP is inserted. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.3 | ColumninformationLocation | read-only | current | Textual description of SFP location. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.4 | ColumninformationStatus | read-only | current | Should indicate OK. LOSS_OF_SIGNAL is shown when the optical receive power level is below the critical lower limit. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.5 | ColumninformationType | read-only | current | This parameter shows which type of optics are installed |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.6 | ColumninformationConnector | read-only | current | Shows which connector is used with this SFP. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.7 | ColumninformationWavelength | read-only | current | Nominal wavelength if this SFP. May also indicate ITU channel for DWDM optics. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.8 | ColumninformationTxTechnology | read-only | current | Distinguishes between multimode and single mode SFP. For DWDM SFP more details including grid are shown. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.9 | ColumninformationRxTechnology | read-only | current | Distinguishes between normal PIN receivers and more sensitive APD receivers. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.10 | ColumninformationNominalBitrate | read-only | current | Nominal bitrate rounded to nearest 100Mbit. Usually the SFP can be operated at lower speed as well. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.11 | ColumninformationManufacturer | read-only | current | Shows the manufacturer of this SFP. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.12 | ColumninformationPartNumber | read-only | current | Shows the part number of this SFP. This will differ from the MICROSENS order code unless also MICROSENS is indicated as manufacturer. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.13 | ColumninformationRevision | read-only | current | Internal revision code of this SFP. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.14 | ColumninformationSerialNumber | read-only | current | Serial number of the SFP. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.15 | ColumninformationMfgDateCode | read-only | current | Manufacturing date code. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.16 | ColumninformationWarnings | read-only | current | |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.17 | ColumninformationAlarms | read-only | current | |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.18 | ColumninformationTxPower | read-only | current | Indicates the optical output in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.19 | ColumninformationRxPower | read-only | current | Indicates the optical input in dBm. Some SFP cannot display this value. For electrical SFP N/A (not applicable) is shown. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.20 | ColumninformationTemperature | read-only | current | Displays the temperature inside the SFP. This is usually higher than the system temperature. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.21 | ColumninformationMaxLength9Um | read-only | current | Displays nominal maximum reach of this SFP on a standard single mode fiber. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.22 | ColumninformationMaxLength50Um | read-only | current | Displays nominal maximum reach of this SFP on a 50 micro meter multimode fiber. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.23 | ColumninformationMaxLength62Um | read-only | current | Displays nominal maximum reach of this SFP on a 62.5 micro meter multimode fiber. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.24 | ColumninformationMaxLengthCopper | read-only | current | Displays nominal maximum reach of this SFP on a copper cable. Only applies to electrical SFP. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.25 | ColumninformationTuningRange | read-only | current | For wavelength tunable optics additional details are shown here. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.26 | ColumninformationPowerConsumption | read-only | current | Typcial power consumption values are shown if available from the interface. |
| 1.3.6.1.4.1.3181.10.6.1.34.100.1.27 | ColumninformationAdditionalInformation | read-only | current | Some special SFP can supply additional measurement data. For example OTDR reflection data can be listed here. |