MIB Viewer

G6-SMARTOFFICE-MIB

127 objects
Microsens private MIB for Generation 6 Ethernet Switches
Imported Objects
MICROSENS-G6-MIBg6
SNMPv2-SMICounter32 enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString MacAddress
OIDNameAccessStatusDescription
1.3.6.1.4.1.3181.10.6.4IdentitydeviceMicrosens private MIB for Generation 6 Ethernet Switches
1.3.6.1.4.1.3181.10.6.4.99Nodesmartoffice
1.3.6.1.4.1.3181.10.6.4.99.1ScalarsmartofficeEnableSmartOfficeread-writecurrentGenerally enable the SmartOffice solution.
1.3.6.1.4.1.3181.10.6.4.99.2TabledirectorConfigTablenot-accessiblecurrentGeneral configuration of the director.
1.3.6.1.4.1.3181.10.6.4.99.2.1RowdirectorConfigEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.4.99.2.1.1ColumndirectorConfigIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.4.99.2.1.2ColumndirectorConfigDomainNameread-writecurrent
1.3.6.1.4.1.3181.10.6.4.99.2.1.3ColumndirectorConfigGeneralModeread-writecurrent
1.3.6.1.4.1.3181.10.6.4.99.2.1.4ColumndirectorConfigActOnUngroupedSensorsread-writecurrentWhen set any sensor attributes which are not configured to be part of a sensor group, will also trigger the regular script execution. This may be selected in s…
1.3.6.1.4.1.3181.10.6.4.99.2.1.5ColumndirectorConfigScanLightControllersread-writecurrentScan the local network for reachable SmartLightController and display a list.
1.3.6.1.4.1.3181.10.6.4.99.3TabledeviceConfigTablenot-accessiblecurrentDefines the configuration of each device under control. A device may contain one or more actor or sensor functions.
1.3.6.1.4.1.3181.10.6.4.99.3.1RowdeviceConfigEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.4.99.3.1.1ColumndeviceConfigIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.4.99.3.1.2ColumndeviceConfigDeviceNameread-writecurrentUnique group name referenced by the director
1.3.6.1.4.1.3181.10.6.4.99.3.1.3ColumndeviceConfigLocationread-writecurrentFree text to describe the position of the controller on the premesis. This value need NOT be savedwithin the sensor itself.
1.3.6.1.4.1.3181.10.6.4.99.3.1.4ColumndeviceConfigLatituderead-writecurrentA value in degrees such as: 50,123
1.3.6.1.4.1.3181.10.6.4.99.3.1.5ColumndeviceConfigLongituderead-writecurrentA value in degrees such as: 50,123
1.3.6.1.4.1.3181.10.6.4.99.3.1.6ColumndeviceConfigAltituderead-writecurrentA value in meters.
1.3.6.1.4.1.3181.10.6.4.99.3.1.7ColumndeviceConfigPlacementread-writecurrentInformation where to find the controller
1.3.6.1.4.1.3181.10.6.4.99.3.1.8ColumndeviceConfigProductTyperead-writecurrentDefines via which network the sensor is reachable.
1.3.6.1.4.1.3181.10.6.4.99.3.1.9ColumndeviceConfigDeviceIdread-writecurrentUnique manufacturer dependent identifier of the device. For SmartLightController the MAC address of the controller is entered here.
1.3.6.1.4.1.3181.10.6.4.99.3.1.10ColumndeviceConfigNetworkAddressread-writecurrentMay be an IP or other type of address depending on the given network access method. Can be left blank for a SmartLightController.
1.3.6.1.4.1.3181.10.6.4.99.3.1.11ColumndeviceConfigAdditionalParameterread-writecurrentComma separated list of any parameter specific for this device. Example: panel=type A,refresh_rate=12
1.3.6.1.4.1.3181.10.6.4.99.3.1.12ColumndeviceConfigNetworkFailureActionread-writecurrentDefines what the actor does if the network connection fails or after reboot until communication is established.
1.3.6.1.4.1.3181.10.6.4.99.3.1.13ColumndeviceConfigIdentifyread-writecurrentThe actor will blink with its status led to signal its presence and physical location.
1.3.6.1.4.1.3181.10.6.4.99.3.1.14ColumndeviceConfigRestartread-writecurrentRestart the actor.
1.3.6.1.4.1.3181.10.6.4.99.3.1.15ColumndeviceConfigCalibrateread-writecurrentStart calibration process (if available for this actor type).
1.3.6.1.4.1.3181.10.6.4.99.3.1.16ColumndeviceConfigPairread-writecurrentStart pairing process that couples individual device to this director.
1.3.6.1.4.1.3181.10.6.4.99.3.1.17ColumndeviceConfigUnpairread-writecurrentDiscard exisiting pairing between an individual device and this director.
1.3.6.1.4.1.3181.10.6.4.99.3.1.18ColumndeviceConfigUpdateFirmwareread-writecurrentUpdate the device firmware. When no file name is supplied, the latest version is automatically selected. Alternatively, a specific file name can be supplied to…
1.3.6.1.4.1.3181.10.6.4.99.4TableactorGroupConfigTablenot-accessiblecurrentDefines a group of actors that support the same attribute and which shall be set toghter to the same value.
1.3.6.1.4.1.3181.10.6.4.99.4.1RowactorGroupConfigEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.4.99.4.1.1ColumnactorGroupConfigIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.4.99.4.1.2ColumnactorGroupConfigGroupNameread-writecurrentUnique group name referenced by the director
1.3.6.1.4.1.3181.10.6.4.99.4.1.3ColumnactorGroupConfigAttributeread-writecurrentThe attribute which is configured. Locally, identical attributes of the associated devices listed below are grouped.
1.3.6.1.4.1.3181.10.6.4.99.4.1.4ColumnactorGroupConfigAssociatedDevicesread-writecurrentList of all actors that supply information to a particular group. When an instance is used, here the syntax devicename.instance is used. All records are comma …
1.3.6.1.4.1.3181.10.6.4.99.4.1.5ColumnactorGroupConfigAdditionalParameterread-writecurrentComma separated list of any parameter specific for this attribute if needed.
1.3.6.1.4.1.3181.10.6.4.99.4.1.6ColumnactorGroupConfigDefaultValueread-writecurrent
1.3.6.1.4.1.3181.10.6.4.99.4.1.7ColumnactorGroupConfigValueCachingread-writecurrentWhen enabled the group target value is saved to local non volaive memory. Should the director restart, the cached values will be restored and send to the devic…
1.3.6.1.4.1.3181.10.6.4.99.4.1.8ColumnactorGroupConfigAdditionalScriptNameread-writecurrentWhen the actor group is updated, an additional script, defined here, can be executed to run time consuming functions outside of the standard processing loop. U…
1.3.6.1.4.1.3181.10.6.4.99.4.1.9ColumnactorGroupConfigManualSetValueread-writecurrentThis command permits setting of the group value manually bypassing the defined script logic. This is intended for testing only. Important: This manual setting …
1.3.6.1.4.1.3181.10.6.4.99.5TablesensorGroupConfigTablenot-accessiblecurrentDefines a group of sensors that support the same attribute and whose data should be interpreted together.
1.3.6.1.4.1.3181.10.6.4.99.5.1RowsensorGroupConfigEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.4.99.5.1.1ColumnsensorGroupConfigIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.4.99.5.1.2ColumnsensorGroupConfigGroupNameread-writecurrentUnique group name referenced by the director
1.3.6.1.4.1.3181.10.6.4.99.5.1.3ColumnsensorGroupConfigAttributeread-writecurrentThe attribute which is configured. Locally, identical attributes of the associated devices listed below are grouped.
1.3.6.1.4.1.3181.10.6.4.99.5.1.4ColumnsensorGroupConfigAssociatedDevicesread-writecurrentList of all sensors that supply information to a particular group. When an instance is used, here the syntax devicename.instance is used. All records are comma…
1.3.6.1.4.1.3181.10.6.4.99.5.1.5ColumnsensorGroupConfigValueCachingread-writecurrentWhen enabled the group target value is saved to local non volaive memory. Should the director restart, the cached values will be restored and send to the devic…
1.3.6.1.4.1.3181.10.6.4.99.5.1.6ColumnsensorGroupConfigRunScriptWhenread-writecurrentDefines which sensor group status needs to change in order to run the standard (and optional additional_script). This can be used to limit the number of script…
1.3.6.1.4.1.3181.10.6.4.99.5.1.7ColumnsensorGroupConfigRunScriptDeltaread-writecurrentDefines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent va…
1.3.6.1.4.1.3181.10.6.4.99.5.1.8ColumnsensorGroupConfigScriptNameread-writecurrentWhen the group is updated and the required conditions are met, the script specified in this parameter is executed. If the parameter is left blank, the standard…
1.3.6.1.4.1.3181.10.6.4.99.5.1.9ColumnsensorGroupConfigAdditionalScriptNameread-writecurrentWhen the group is updated and the required conditions are met and a script is defined here, this script is executed in the background after the standard proces…
1.3.6.1.4.1.3181.10.6.4.99.5.1.10ColumnsensorGroupConfigReportModeread-writecurrentDefines if the sensor is passive or actively reports changes and error conditions
1.3.6.1.4.1.3181.10.6.4.99.5.1.11ColumnsensorGroupConfigAdditionalParameterread-writecurrentComma separated list of any parameter specific for this attribute if needed.
1.3.6.1.4.1.3181.10.6.4.99.5.1.12ColumnsensorGroupConfigLowerBoundaryread-writecurrentWhen the measured value of any sensor is equal or below this value an event is raised. The value may be configured directly with a numerical value optionally f…
1.3.6.1.4.1.3181.10.6.4.99.5.1.13ColumnsensorGroupConfigUpperBoundaryread-writecurrentWhen the measured value of any sensor is equal or above this value an event is raised. The value may be configured directly with a numerical value optionally f…
1.3.6.1.4.1.3181.10.6.4.99.5.1.14ColumnsensorGroupConfigBoundaryHysteresisread-writecurrentHow much the value must return within bounds before the alarm condition is cleared.
1.3.6.1.4.1.3181.10.6.4.99.5.1.15ColumnsensorGroupConfigUpdateDeltaread-writecurrentDefines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent va…
1.3.6.1.4.1.3181.10.6.4.99.5.1.16ColumnsensorGroupConfigRateLimitread-writecurrentDefines how quickly the value is reported. Defined In units of 100ms. 0 means no rate limiting.
1.3.6.1.4.1.3181.10.6.4.99.5.1.17ColumnsensorGroupConfigClearValuesread-writecurrentClear status values for minimum_peak_hold and maximum_peak_hold.
1.3.6.1.4.1.3181.10.6.4.99.100TabledeviceInformationTablenot-accessiblecurrentSummarizes the most important inventory information of each detected device.
1.3.6.1.4.1.3181.10.6.4.99.100.1RowdeviceInformationEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.4.99.100.1.1ColumndeviceInformationIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.4.99.100.1.2ColumndeviceInformationNameread-onlycurrentUnique name for reference. This is name of the base device.
1.3.6.1.4.1.3181.10.6.4.99.100.1.3ColumndeviceInformationHardwareIdread-onlycurrentA product specific hardware identification. May for example contain the MAC address.
1.3.6.1.4.1.3181.10.6.4.99.100.1.4ColumndeviceInformationDeviceTyperead-onlycurrentIndicates if this is an actor or sensor device.
1.3.6.1.4.1.3181.10.6.4.99.100.1.5ColumndeviceInformationOperationalStateread-onlycurrentIndicates the operational state of the device. Device (not attribute) specific errors will be indicated here.
1.3.6.1.4.1.3181.10.6.4.99.100.1.6ColumndeviceInformationActorAttributesread-onlycurrentLists which setable actor attributes are provided by this device.
1.3.6.1.4.1.3181.10.6.4.99.100.1.7ColumndeviceInformationSensorAttributesread-onlycurrentLists which readable sensor attributes are provided by this device.
1.3.6.1.4.1.3181.10.6.4.99.100.1.8ColumndeviceInformationVendorNameread-onlycurrentVendor or manufacturer name of the device.
1.3.6.1.4.1.3181.10.6.4.99.100.1.9ColumndeviceInformationArticleNumberread-onlycurrentThis device article number.
1.3.6.1.4.1.3181.10.6.4.99.100.1.10ColumndeviceInformationSerialNumberread-onlycurrentThis device serial number.
1.3.6.1.4.1.3181.10.6.4.99.100.1.11ColumndeviceInformationHardwareRevisionread-onlycurrentThis device hardware version.
1.3.6.1.4.1.3181.10.6.4.99.100.1.12ColumndeviceInformationSoftwareVersionread-onlycurrentThis device software / firmware version.
1.3.6.1.4.1.3181.10.6.4.99.100.1.13ColumndeviceInformationAdditionalInforead-onlycurrentOptional comma separated list of status fields specific for this type of device.
1.3.6.1.4.1.3181.10.6.4.99.101TableactorListTablenot-accessiblecurrentThis table lists all currenly registered actors with all their attributes.
1.3.6.1.4.1.3181.10.6.4.99.101.1RowactorListEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.4.99.101.1.1ColumnactorListIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.4.99.101.1.2ColumnactorListDeviceread-onlycurrentThis is name of the base device which controls this actor. There may be several actor types (attributes) in the same device and these share the same name but u…
1.3.6.1.4.1.3181.10.6.4.99.101.1.3ColumnactorListInstanceread-onlycurrentDescribes a unique instance when several similar functional attributes are existing in the same device
1.3.6.1.4.1.3181.10.6.4.99.101.1.4ColumnactorListAttributeread-onlycurrentThe kind of function this actor is acting on
1.3.6.1.4.1.3181.10.6.4.99.101.1.5ColumnactorListAssociatedGroupsread-onlycurrentIndicates in which actor_groups this actor takes part.
1.3.6.1.4.1.3181.10.6.4.99.101.1.6ColumnactorListValueread-onlycurrentThe currently set value as text string followed by the unit such as mA or Lux.
1.3.6.1.4.1.3181.10.6.4.99.101.1.7ColumnactorListActorStateread-onlycurrentIndicates wether the indicated value was successfully written to the actual device.
1.3.6.1.4.1.3181.10.6.4.99.101.1.8ColumnactorListLastUpdateread-onlycurrentIndicates the time when this record was last updated.
1.3.6.1.4.1.3181.10.6.4.99.102TablesensorListTablenot-accessiblecurrentThis table lists all currenly registered sensors with all their attributes.
1.3.6.1.4.1.3181.10.6.4.99.102.1RowsensorListEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.4.99.102.1.1ColumnsensorListIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.4.99.102.1.2ColumnsensorListDeviceread-onlycurrentThis is name of the base device which controls this sensor. There may be several different sensor types (attributes) in the same device. These share the same n…
1.3.6.1.4.1.3181.10.6.4.99.102.1.3ColumnsensorListInstanceread-onlycurrentDescribes a unique instance when several similar functional attributes are existing in the same device
1.3.6.1.4.1.3181.10.6.4.99.102.1.4ColumnsensorListAttributeread-onlycurrentThe kind of measurement this sensor is reporting.
1.3.6.1.4.1.3181.10.6.4.99.102.1.5ColumnsensorListAssociatedGroupsread-onlycurrentIndicates in which sensor_groups this sensor takes part.
1.3.6.1.4.1.3181.10.6.4.99.102.1.6ColumnsensorListValueread-onlycurrentThe last reported value as text string followed by the unit such as mA or Lux.
1.3.6.1.4.1.3181.10.6.4.99.102.1.7ColumnsensorListSensorStateread-onlycurrentIndicates particular sensor states such hitting a boundary.
1.3.6.1.4.1.3181.10.6.4.99.102.1.8ColumnsensorListLastUpdateread-onlycurrentIndicates the time when this record was last updated.
1.3.6.1.4.1.3181.10.6.4.99.103TableactorGroupStatusTablenot-accessiblecurrentCalculated status of the defined actor groups. The listed value reflects the value all associated actors should use. The values update when an actor group is s…
1.3.6.1.4.1.3181.10.6.4.99.103.1RowactorGroupStatusEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.4.99.103.1.1ColumnactorGroupStatusIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.4.99.103.1.2ColumnactorGroupStatusGroupNameread-onlycurrentThis is name mirrors the actor_group_configuration.
1.3.6.1.4.1.3181.10.6.4.99.103.1.3ColumnactorGroupStatusAttributeread-onlycurrentThe name of the controlled attribute.
1.3.6.1.4.1.3181.10.6.4.99.103.1.4ColumnactorGroupStatusNumAssignedActorsread-onlycurrentNumber of actors that are configured for this group.
1.3.6.1.4.1.3181.10.6.4.99.103.1.5ColumnactorGroupStatusNumFailedActorsread-onlycurrentNumber of actors that have not responded as expected.
1.3.6.1.4.1.3181.10.6.4.99.103.1.6ColumnactorGroupStatusGroupStateread-onlycurrent
1.3.6.1.4.1.3181.10.6.4.99.103.1.7ColumnactorGroupStatusValueread-onlycurrentThis value is set by the decision logic. May contain simple on,OFF or for example a sound file name
1.3.6.1.4.1.3181.10.6.4.99.103.1.8ColumnactorGroupStatusActivePriorityread-onlycurrentIndicates which priority level is currently controlling the group value. Lower values have higher priority.
1.3.6.1.4.1.3181.10.6.4.99.103.1.9ColumnactorGroupStatusPriorityValueChainread-onlycurrentDisplays the prority=value pairs of all currently defined priority levels. Relinquished priorites are not shown.
1.3.6.1.4.1.3181.10.6.4.99.103.1.10ColumnactorGroupStatusCacheStatusread-onlycurrentIndicates if this group_status is saved even upon system power loss or reboot.
1.3.6.1.4.1.3181.10.6.4.99.103.1.11ColumnactorGroupStatusLastUpdateread-onlycurrentIndicates the time when this group status was last updated.
1.3.6.1.4.1.3181.10.6.4.99.104TablesensorGroupStatusTablenot-accessiblecurrentCalculated status for all sensor groups. The sensor values of all contributing sensors are used to calculate min, max and average values. The values update eac…
1.3.6.1.4.1.3181.10.6.4.99.104.1RowsensorGroupStatusEntrynot-accessiblecurrent
1.3.6.1.4.1.3181.10.6.4.99.104.1.1ColumnsensorGroupStatusIndexnot-accessiblecurrentAutomatically generated
1.3.6.1.4.1.3181.10.6.4.99.104.1.2ColumnsensorGroupStatusGroupNameread-onlycurrentThis is name mirrors the sensor_group_configuration.
1.3.6.1.4.1.3181.10.6.4.99.104.1.3ColumnsensorGroupStatusAttributeread-onlycurrentThe name of the attribute measured. E.g. brightness, motion, switch.
1.3.6.1.4.1.3181.10.6.4.99.104.1.4ColumnsensorGroupStatusNumAssignedSensorsread-onlycurrentNumber of sensors that are configured for this group.
1.3.6.1.4.1.3181.10.6.4.99.104.1.5ColumnsensorGroupStatusNumFailedSensorsread-onlycurrentNumber of sensors that have not responded as expected.
1.3.6.1.4.1.3181.10.6.4.99.104.1.6ColumnsensorGroupStatusGroupStateread-onlycurrentInforms when not all sensors operate as expected.
1.3.6.1.4.1.3181.10.6.4.99.104.1.7ColumnsensorGroupStatusMinimumPeakHoldread-onlycurrentMinimum value ever reported in this group since last value clear.
1.3.6.1.4.1.3181.10.6.4.99.104.1.8ColumnsensorGroupStatusMinimumValueread-onlycurrentMinimum value out of all sensors that report to this group.
1.3.6.1.4.1.3181.10.6.4.99.104.1.9ColumnsensorGroupStatusAverageValueread-onlycurrentAverage value out of all sensors that report to this group. Uses the number of reporting sensors to calculate the average.
1.3.6.1.4.1.3181.10.6.4.99.104.1.10ColumnsensorGroupStatusMaximumValueread-onlycurrentMaximum value out of all sensors that report to this group.
1.3.6.1.4.1.3181.10.6.4.99.104.1.11ColumnsensorGroupStatusMaximumPeakHoldread-onlycurrentMaximum value ever reported in this group since last value clear.
1.3.6.1.4.1.3181.10.6.4.99.104.1.12ColumnsensorGroupStatusTotalValueread-onlycurrentThe total sum of all individual sensor values in this group.
1.3.6.1.4.1.3181.10.6.4.99.104.1.13ColumnsensorGroupStatusLowerBoundaryReachedread-onlycurrentNumber of sensors that have reached their lower threshold. A value of 0 means no sensor has reached a lower boundary.
1.3.6.1.4.1.3181.10.6.4.99.104.1.14ColumnsensorGroupStatusUpperBoundaryReachedread-onlycurrentNumber of sensors that have reached their upper threshold. A value of 0 means no sensor has reached an upper boundary.
1.3.6.1.4.1.3181.10.6.4.99.104.1.15ColumnsensorGroupStatusUpdatingSensorIndexread-onlycurrentIndicates the index to the sensor_list which has caused the latest group update.
1.3.6.1.4.1.3181.10.6.4.99.104.1.16ColumnsensorGroupStatusCacheStatusread-onlycurrentIndicates if this attribute is saved even upon system power loss or reboot.
1.3.6.1.4.1.3181.10.6.4.99.104.1.17ColumnsensorGroupStatusLastUpdateread-onlycurrentIndicates the time when this group status was last updated.