MIB Viewer

GBNDevicePoe-MIB

28 objects
Gbn Common Enterprise MIB definition.
OIDNameAccessStatusDescription
1.3.6.1.4.1.13464.1.2.2.4IdentitygbnDevicePoeGbn Common Enterprise MIB definition.
1.3.6.1.4.1.13464.1.2.2.4.2TablepoePowerSupplyTablenot-accessiblecurrentA table of power supply.
1.3.6.1.4.1.13464.1.2.2.4.2.1RowpoePowerSupplyEntrynot-accessiblecurrentA table of power supply.
1.3.6.1.4.1.13464.1.2.2.4.2.1.1Columnpowerindexread-onlycurrentunit index, start from 1
1.3.6.1.4.1.13464.1.2.2.4.2.1.2ColumnpoeVersionread-onlycurrentA string of poe firmware.
1.3.6.1.4.1.13464.1.2.2.4.2.1.3Columnpowerstatusread-onlycurrentdescriptions of power supply
1.3.6.1.4.1.13464.1.2.2.4.2.1.4ColumnpoeDevicePowerLimitread-writecurrentpower limit of device.unit is Watt
1.3.6.1.4.1.13464.1.2.2.4.2.1.5ColumnpoeDevicePowerConsumeread-onlycurrentpower consumption of device.unit is Watt
1.3.6.1.4.1.13464.1.2.2.4.4TablepoePortTablenot-accessiblecurrentA table of poe port.
1.3.6.1.4.1.13464.1.2.2.4.4.1RowpoePortEntrynot-accessiblecurrentA table of poe port.
1.3.6.1.4.1.13464.1.2.2.4.4.1.1ColumnportIndexread-onlycurrentport index, start from 1
1.3.6.1.4.1.13464.1.2.2.4.4.1.2Columnpowerlimitread-writecurrentpower limit of port.unit is mW
1.3.6.1.4.1.13464.1.2.2.4.4.1.3ColumnpowerConsumeread-onlycurrentpower consumption of port.unit is mW
1.3.6.1.4.1.13464.1.2.2.4.5TablepoePdPortTablenot-accessiblecurrentA table of poe port.
1.3.6.1.4.1.13464.1.2.2.4.5.1RowpoePdPortEntrynot-accessiblecurrentA table of poe port.
1.3.6.1.4.1.13464.1.2.2.4.5.1.1ColumnportPdIndexread-onlycurrentport index, start from 1
1.3.6.1.4.1.13464.1.2.2.4.5.1.2ColumnportPoePdEnableread-onlycurrentpoe feedback real time port enable state.unit is mW
1.3.6.1.4.1.13464.1.2.2.4.5.1.3ColumnportPoePdConfigread-writecurrentpoe feedback config port enable.unit is mW
1.3.6.1.4.1.13464.1.2.2.4.6TablepoeFanControlTablenot-accessiblecurrentA table of poe fan set.
1.3.6.1.4.1.13464.1.2.2.4.6.1RowpoeFanControlEntrynot-accessiblecurrentA table of poe fan set.
1.3.6.1.4.1.13464.1.2.2.4.6.1.1ColumnpoeFandefaultread-onlycurrentpoe fans' mode set or get.
1.3.6.1.4.1.13464.1.2.2.4.6.1.2ColumnpoeFanlowVauleread-writecurrentpoe fan-control low-temperature
1.3.6.1.4.1.13464.1.2.2.4.6.1.3ColumnpoeFanmiddleVauleread-writecurrentpoe fan-control middle-temperature
1.3.6.1.4.1.13464.1.2.2.4.6.1.4ColumnpoeFanhighVauleread-writecurrentpoe fan-control high-temperature
1.3.6.1.4.1.13464.1.2.2.4.6.1.5ColumnpoeFanModeSetread-writecurrentpoe fan-control user defined set
1.3.6.1.4.1.13464.1.2.2.4.6.1.6ColumnpoeFan1Speedread-onlycurrentthe fan1 speed of the switch
1.3.6.1.4.1.13464.1.2.2.4.6.1.7ColumnpoeFan2Speedread-onlycurrentthe fan2 speed of the switch
1.3.6.1.4.1.13464.1.2.2.4.6.1.8ColumnpoeTemperatureread-onlycurrentthe temperture of the switch