MIB Viewer

GC-MIB

83 objects
Riverbed Technology SteelFusion Core MIB
Imported Objects
RBT-MIBproducts
SNMPv2-SMICounter64 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks Unsigned32
SNMPv2-TCDateAndTime
OIDNameAccessStatusDescription
1.3.6.1.4.1.17163.1.100IdentitygcRiverbed Technology SteelFusion Core MIB
1.3.6.1.4.1.17163.1.100.1Nodesystem
1.3.6.1.4.1.17163.1.100.1.1Scalarmodelread-onlycurrentAppliance model
1.3.6.1.4.1.17163.1.100.1.2ScalarserialNumberread-onlycurrentAppliance serial number
1.3.6.1.4.1.17163.1.100.1.3ScalarsystemVersionread-onlycurrentSystem software version string
1.3.6.1.4.1.17163.1.100.2Nodestatus
1.3.6.1.4.1.17163.1.100.2.1ScalarsystemClockread-onlycurrentSystem clock time
1.3.6.1.4.1.17163.1.100.2.2Scalarhealthread-onlycurrentCurrent health
1.3.6.1.4.1.17163.1.100.2.3ScalarsystemHealthread-onlycurrentCurrent health of the system. This variable is identical to health except that it is of integer datatype
1.3.6.1.4.1.17163.1.100.2.4ScalarsystemTemperatureread-onlycurrentThe temperature of the system (C)
1.3.6.1.4.1.17163.1.100.2.11TableprocTablenot-accessiblecurrentList of managed processes
1.3.6.1.4.1.17163.1.100.2.11.1RowprocEntrynot-accessiblecurrentEntry for one process
1.3.6.1.4.1.17163.1.100.2.11.1.1ColumnprocIndexnot-accessiblecurrentSynthetic numeric unique ID of process
1.3.6.1.4.1.17163.1.100.2.11.1.2ColumnprocNameread-onlycurrentUnique name of process
1.3.6.1.4.1.17163.1.100.2.11.1.3ColumnprocStatusread-onlycurrentCurrent state of process
1.3.6.1.4.1.17163.1.100.2.11.1.4ColumnprocNumFailuresread-onlycurrentNumber of times process has crashed or exited unexpectedly
1.3.6.1.4.1.17163.1.100.3Nodeconfig
1.3.6.1.4.1.17163.1.100.3.1ScalaractiveConfigread-onlycurrentCurrent active configuration
1.3.6.1.4.1.17163.1.100.4Nodealarms
1.3.6.1.4.1.17163.1.100.4.0NodealarmsPrefix
1.3.6.1.4.1.17163.1.100.4.0.1NotificationprocCrashcurrentA procCrash trap signifies that a process managed by PM has crashed and left a core file. The variable sent with the notification indicates which process crash…
1.3.6.1.4.1.17163.1.100.4.0.2NotificationprocExitcurrentA procExit trap signifies that a process managed by PM has exited unexpectedly, but not left a core file. The variable sent with the notification indicates whi…
1.3.6.1.4.1.17163.1.100.4.0.3NotificationconfigChangecurrentA change has been made to the system's configuration
1.3.6.1.4.1.17163.1.100.4.0.4NotificationcpuUtilcurrentThe average CPU utilization in the past minute has gone above the acceptable threshold
1.3.6.1.4.1.17163.1.100.4.0.5NotificationpagingActivitycurrentThe system has been paging excessively (thrashing)
1.3.6.1.4.1.17163.1.100.4.0.6NotificationlinkErrorcurrentAn interface on the appliance has lost its link
1.3.6.1.4.1.17163.1.100.4.0.7NotificationpowerSupplyErrorcurrentA power supply on the appliance has failed
1.3.6.1.4.1.17163.1.100.4.0.8NotificationfanErrorcurrentA fan has failed on this appliance
1.3.6.1.4.1.17163.1.100.4.0.9NotificationmemoryErrorcurrentA memory error has been detected on the appliance
1.3.6.1.4.1.17163.1.100.4.0.10NotificationipmicurrentAn IPMI event has been detected on the appliance. Please check the details in the alarm report on the web UI
1.3.6.1.4.1.17163.1.100.4.0.11NotificationlocalFSFullcurrentThe appliance local filesystem is full.
1.3.6.1.4.1.17163.1.100.4.0.12NotificationtemperatureCriticalcurrentThe system temperature has reached a critical stage
1.3.6.1.4.1.17163.1.100.4.0.13NotificationtemperatureWarningcurrentThe system temperature has exceeded the threshold
1.3.6.1.4.1.17163.1.100.4.0.14NotificationscheduledJobErrorcurrentA scheduled job has failed during execution
1.3.6.1.4.1.17163.1.100.4.0.15NotificationconfModeEntercurrentA user has entered configuration mode
1.3.6.1.4.1.17163.1.100.4.0.16NotificationconfModeExitcurrentA user has exited configuration mode
1.3.6.1.4.1.17163.1.100.4.0.17NotificationsecureVaultLockedcurrentSecure vault is locked. The secure datastore cannot be used.
1.3.6.1.4.1.17163.1.100.4.0.18NotificationprocRestartcurrentA procRestart trap signifies that a process managed by PM has restarted. The variable sent with the notification indicates which process restarted.
1.3.6.1.4.1.17163.1.100.4.0.19NotificationtestTrapcurrentThis is a test trap.
1.3.6.1.4.1.17163.1.100.4.0.1004NotificationcpuUtilClearcurrentThe average CPU utilization has fallen back within the acceptable threshold
1.3.6.1.4.1.17163.1.100.4.0.1005NotificationpagingActivityClearcurrentThe system has stopped paging excessively (thrashing)
1.3.6.1.4.1.17163.1.100.4.0.1006NotificationlinkErrorClearcurrentAn interface on the appliance has regained its link
1.3.6.1.4.1.17163.1.100.4.0.1007NotificationpowerSupplyErrorClearcurrentAll power supplies are now functioning normally
1.3.6.1.4.1.17163.1.100.4.0.1008NotificationfanErrorClearcurrentAll system fans are now functioning normally
1.3.6.1.4.1.17163.1.100.4.0.1009NotificationmemoryErrorClearcurrentA memory error has been rectified on the appliance
1.3.6.1.4.1.17163.1.100.4.0.1010NotificationipmiClearcurrentAn IPMI event has been rectified on the appliance
1.3.6.1.4.1.17163.1.100.4.0.1011NotificationlocalFSFullClearcurrentThe appliance local filesystem usage is below threshold.
1.3.6.1.4.1.17163.1.100.4.0.1012NotificationtemperatureNonCriticalcurrentThe system temperature is no longer in a critical stage
1.3.6.1.4.1.17163.1.100.4.0.1013NotificationtemperatureNormalcurrentThe system temperature is back within the threshold
1.3.6.1.4.1.17163.1.100.4.0.1017NotificationsecureVaultUnlockedcurrentSecure vault is unlocked. The secure data store can be used now.
1.3.6.1.4.1.17163.1.100.4.0.10500NotificationedgeErrorcurrentEdge module encountered error.
1.3.6.1.4.1.17163.1.100.4.0.10501NotificationhighAvailabilityErrorcurrentHigh Availability module encountered error.
1.3.6.1.4.1.17163.1.100.4.0.10502NotificationlunErrorcurrentLun module encountered error.
1.3.6.1.4.1.17163.1.100.4.0.10503NotificationiscsiErrorcurrentiSCSI module encountered error.
1.3.6.1.4.1.17163.1.100.4.0.10505NotificationsnapshotErrorcurrentSnapshot module encountered error.
1.3.6.1.4.1.17163.1.100.4.0.10506NotificationapplianceUnlicensedErrorcurrentAppliance license expired/invalid.
1.3.6.1.4.1.17163.1.100.4.0.10507NotificationmodelUnlicensedErrorcurrentModel license expired/invalid.
1.3.6.1.4.1.17163.1.100.4.0.10508NotificationblkdiskErrorcurrentBlock-disk module encountered error.
1.3.6.1.4.1.17163.1.100.4.0.10509NotificationbackupIntegrationErrorcurrentBackup-Integration module encountered error.
1.3.6.1.4.1.17163.1.100.4.0.10510NotificationotherHardwareErrorcurrentHardware Error detected.
1.3.6.1.4.1.17163.1.100.4.0.11500NotificationedgeClearcurrentEdge module error cleared.
1.3.6.1.4.1.17163.1.100.4.0.11501NotificationhighAvailabilityClearcurrentHigh Availability module error cleared.
1.3.6.1.4.1.17163.1.100.4.0.11502NotificationlunClearcurrentLun module error cleared.
1.3.6.1.4.1.17163.1.100.4.0.11503NotificationiscsiClearcurrentiSCSI module error cleared.
1.3.6.1.4.1.17163.1.100.4.0.11505NotificationsnapshotClearcurrentSnapshot module error cleared.
1.3.6.1.4.1.17163.1.100.4.0.11506NotificationapplianceUnlicensedClearcurrentAppliance license active.
1.3.6.1.4.1.17163.1.100.4.0.11507NotificationmodelUnlicensedClearcurrentModel license active.
1.3.6.1.4.1.17163.1.100.4.0.11508NotificationblkdiskClearcurrentBlock-disk module error cleared.
1.3.6.1.4.1.17163.1.100.4.0.11509NotificationbackupIntegrationClearcurrentBackup-Integration module error cleared.
1.3.6.1.4.1.17163.1.100.4.0.11510NotificationotherHardwareClearcurrentHardware error cleared.
1.3.6.1.4.1.17163.1.100.5Nodestatistics
1.3.6.1.4.1.17163.1.100.5.1NodecpuLoad
1.3.6.1.4.1.17163.1.100.5.1.1ScalarcpuLoad1read-onlycurrentOne-minute CPU load in hundreths
1.3.6.1.4.1.17163.1.100.5.1.2ScalarcpuLoad5read-onlycurrentOne-minute CPU load in hundreths
1.3.6.1.4.1.17163.1.100.5.1.3ScalarcpuLoad15read-onlycurrentFifteen-minute CPU load in hundreths
1.3.6.1.4.1.17163.1.100.5.1.4ScalarcpuUtil1read-onlycurrentPercentage CPU utilization, aggregated across all CPUs, rolling average over the past minute
1.3.6.1.4.1.17163.1.100.5.1.5TablecpuIndivUtilTablenot-accessiblecurrentDetails about the individual CPU utilization
1.3.6.1.4.1.17163.1.100.5.1.5.1RowcpuIndivUtilEntrynot-accessiblecurrentEntry for one cpu
1.3.6.1.4.1.17163.1.100.5.1.5.1.1ColumncpuIndivIndexnot-accessiblecurrentA synthetic number numbering the cpus
1.3.6.1.4.1.17163.1.100.5.1.5.1.2ColumncpuIndivIdread-onlycurrentName of the cpu, also serves as the Index for the table
1.3.6.1.4.1.17163.1.100.5.1.5.1.3ColumncpuIndivIdleTimeread-onlycurrentIdle time for this CPU
1.3.6.1.4.1.17163.1.100.5.1.5.1.4ColumncpuIndivSystemTimeread-onlycurrentSystem time for this CPU
1.3.6.1.4.1.17163.1.100.5.1.5.1.5ColumncpuIndivUserTimeread-onlycurrentUser time for this CPU