GIGAMON-SNMP-MIB
76 objects
Added notification type: - gigamonSnmpBpsFailoverNotification Added notification objects: - gigamonSnmpNotifBpsUnitName - gigamonSnmpNotifBpsFailoverStatus
Imported Objects
| RFC1213-MIB | sysLocation |
| SNMPv2-SMI | enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString PhysAddress TEXTUAL-CONVENTION TimeStamp |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.26866 | IdentitygigamonSnmp | Added notification type: - gigamonSnmpBpsFailoverNotification Added notification objects: - gigamonSnmpNotifBpsUnitName - gigamonSnmpNotifBpsFailoverStatus | ||
| 1.3.6.1.4.1.26866.1 | NodegigamonSnmpNotifications | |||
| 1.3.6.1.4.1.26866.1.1 | NodegigamonGigaVUE | |||
| 1.3.6.1.4.1.26866.1.1.1 | NotificationgigamonSnmpResetSystemNotification | current | System reset notification triggered by cold or warm start. | |
| 1.3.6.1.4.1.26866.1.1.2 | NotificationgigamonSnmpUserAuthFailNotification | current | Failure in user login operation is the triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.3 | NotificationgigamonSnmpFirmwareChangeNotification | current | Firmware Change notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.4 | NotificationgigamonSnmpConfigSaveNotification | current | Config save notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.5 | NotificationgigamonSnmpModuleChangeNotification | current | GigaVUE HW module swapping is the triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.6 | NotificationgigamonSnmpPacketDropNotification | current | Packet Drop notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.7 | NotificationgigamonSnmpTapRelayChangeNotification | current | TAP relay change notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.8 | NotificationgigamonSnmpPortLinkChangeNotification | current | Port link status change notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.9 | NotificationgigamonSnmpRxTxErrorNotification | current | Packet receive/transmit error notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.10 | NotificationgigamonPowerChangeNotification | current | Power supply status change notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.11 | NotificationgigamonFanChangeNotification | current | Fan status change notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.12 | NotificationgigamonSnmpOverThresholdChangeNotification | current | Utilization alarm notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.1.13 | NotificationgigamonSnmpBatteryLevelChangeNotification | current | Battery level down notification. | |
| 1.3.6.1.4.1.26866.1.1.14 | NotificationgigamonLinkSpeedStatusChangeNotification | current | Link status or speed change notification. | |
| 1.3.6.1.4.1.26866.1.1.15 | NotificationgigamonPowerSourceChangeNotification | current | Power source or status change notification. | |
| 1.3.6.1.4.1.26866.1.1.16 | NotificationgigamonSnmpCpuUtilHighNotification | current | The average CPU utilization in the past minute has gone above the acceptable threshold | |
| 1.3.6.1.4.1.26866.1.1.17 | NotificationgigamonSnmpUnexpectedShutdownNotification | current | The system has shut down unexpectedly | |
| 1.3.6.1.4.1.26866.1.1.18 | NotificationgigamonSnmpDiskSpaceLowNotification | current | Free space in one of the filesystems is low | |
| 1.3.6.1.4.1.26866.1.1.19 | NotificationgigamonSnmpWatchdogResetNotification | current | System reset notification triggered by watchdog timer. | |
| 1.3.6.1.4.1.26866.1.1.20 | NotificationgigamonSnmpBpsFailoverNotification | current | Inline-bypass active unit change notification is the Edge/Level Triggered Event. | |
| 1.3.6.1.4.1.26866.1.2 | NodegigamonSnmpNotificationObjects | |||
| 1.3.6.1.4.1.26866.1.2.1 | ScalargigamonSnmpNotifLevel | accessible-for-notify | current | It acts as a payload for the level of Gigamon's Notifications. |
| 1.3.6.1.4.1.26866.1.2.2 | ScalargigamonSnmpNotifDescription | accessible-for-notify | current | It acts as a payload for the description of Gigamon's Notifications. The value is to describe the reason for the notification. |
| 1.3.6.1.4.1.26866.1.2.3 | ScalargigamonSnmpNotifOpType | accessible-for-notify | current | It specifies the type of operation of Gigamon's Notifications. |
| 1.3.6.1.4.1.26866.1.2.4 | ScalargigamonSnmpNotifPortName | accessible-for-notify | current | The alpha-numerical name of a port shown in Gigamon's Notifications. |
| 1.3.6.1.4.1.26866.1.2.5 | ScalargigamonSnmpNotifPortLinkStatus | accessible-for-notify | current | It indicates port link status of Gigamon's Notifications. |
| 1.3.6.1.4.1.26866.1.2.6 | ScalargigamonSnmpNotifTAPRelayStatus | accessible-for-notify | current | It indicates TAP relay status of Gigamon's Notifications. |
| 1.3.6.1.4.1.26866.1.2.7 | ScalargigamonSnmpNotifRxTxType | accessible-for-notify | current | It indicates Incoming/RX or outgoing/TX packets |
| 1.3.6.1.4.1.26866.1.2.8 | ScalargigamonSnmpNotifRxTxErrorType | accessible-for-notify | current | It indicates RX/TX error type of Gigamon's Notifications. |
| 1.3.6.1.4.1.26866.1.2.9 | ScalargigamonSnmpNotifCounter | accessible-for-notify | current | 32-bit Counter. |
| 1.3.6.1.4.1.26866.1.2.10 | ScalargigamonSnmpNotifFirmwareName | accessible-for-notify | current | Name of GigaVUE firmware. |
| 1.3.6.1.4.1.26866.1.2.11 | ScalargigamonSnmpNotifModuleOperationType | accessible-for-notify | current | It indicates the operation performed on module |
| 1.3.6.1.4.1.26866.1.2.12 | ScalargigamonSnmpNotifModuleName | accessible-for-notify | current | Module name of GigaVUE module |
| 1.3.6.1.4.1.26866.1.2.13 | ScalargigamonNotifSlotNumber | accessible-for-notify | current | Slot number |
| 1.3.6.1.4.1.26866.1.2.14 | ScalargigamonSnmpNotifUserName | accessible-for-notify | current | User login name typed in |
| 1.3.6.1.4.1.26866.1.2.15 | ScalargigamonSnmpNotifFileName | accessible-for-notify | current | Saved configuration file name |
| 1.3.6.1.4.1.26866.1.2.16 | ScalargigamonNotifPowerStatus | accessible-for-notify | current | Power Status |
| 1.3.6.1.4.1.26866.1.2.17 | ScalargigamonSnmpNotifHardWareName | accessible-for-notify | current | Description of Hardware |
| 1.3.6.1.4.1.26866.1.2.18 | ScalargigamonSnmpNotifGigaVUE420SlotNumber | accessible-for-notify | current | Slot number |
| 1.3.6.1.4.1.26866.1.2.19 | ScalargigamonSnmpNotifFanName | accessible-for-notify | current | Name of fan |
| 1.3.6.1.4.1.26866.1.2.20 | ScalargigamonNotifFanStatus | accessible-for-notify | current | Fan Status |
| 1.3.6.1.4.1.26866.1.2.21 | ScalargigamonSnmpNotifUtilizationAlarm | accessible-for-notify | current | It indicates over-threshold port utilization alarm of Gigamon's Notifications. |
| 1.3.6.1.4.1.26866.1.2.22 | ScalargigamonSnmpNotifUtilizationThreshold | accessible-for-notify | current | Utilization threshold percentage |
| 1.3.6.1.4.1.26866.1.2.23 | ScalargigamonSnmpBatteryLevel | read-only | current | battery level: 0 - battery charge complete 1 - battery level has been down below 75% 2 - battery level has been down below 50% 3 - battery level has been down … |
| 1.3.6.1.4.1.26866.1.2.24 | ScalargigamonSnmpPortLinkSpeed | accessible-for-notify | current | port link speed: 0 - Not Apply if link is down 1 - 10 Mbps 2 - 100 Mbps 3 - 1000 Mbps 4 - 10000 Mbps 5 - 40000 Mbps 6 - 100000 Mbps |
| 1.3.6.1.4.1.26866.1.2.25 | ScalargigamonSnmpPortLinkDuplex | accessible-for-notify | current | port link duplex: 0 - Not Apply if link is down 1 - full duplex 2 - half duplex |
| 1.3.6.1.4.1.26866.1.2.26 | ScalargigamonSnmpNotifCpuIndex | accessible-for-notify | current | Index of CPU, starting from 0 |
| 1.3.6.1.4.1.26866.1.2.27 | ScalargigamonSnmpNotifFsMountPoint | accessible-for-notify | current | Mount point for this filesystem |
| 1.3.6.1.4.1.26866.1.2.28 | ScalargigamonSnmpPowerSource | read-only | current | power source: 0 - main power 1 - poe(Power over Ethernet) 2 - -48V Power |
| 1.3.6.1.4.1.26866.1.2.29 | ScalargigamonSnmpNotifBpsUnitName | accessible-for-notify | current | Name of BPS unit |
| 1.3.6.1.4.1.26866.1.2.30 | ScalargigamonSnmpNotifBpsFailoverStatus | accessible-for-notify | current | Inline-bypass active unit change |
| 1.3.6.1.4.1.26866.2 | NodegigamonSystem | |||
| 1.3.6.1.4.1.26866.2.1 | Scalarmanufacturer | read-only | current | Displays the manufacturer name of the system. |
| 1.3.6.1.4.1.26866.2.2 | Scalarmodel | read-only | current | Displays the model name of the system. |
| 1.3.6.1.4.1.26866.2.3 | Scalarname | read-only | current | Displays the name of the system. |
| 1.3.6.1.4.1.26866.2.4 | ScalarserialNumber | read-only | current | Displays the serial number of the system. |
| 1.3.6.1.4.1.26866.2.5 | ScalarsystemDescription | read-only | current | Displays the description of the system. |
| 1.3.6.1.4.1.26866.2.6 | Scalarversion | read-only | current | Displays the software version of the system. |
| 1.3.6.1.4.1.26866.2.7 | ScalarchassisModelNumber | read-only | current | Displays the chassis model number of the system. |
| 1.3.6.1.4.1.26866.2.8 | ScalarchassisSerialNumber | read-only | current | Displays the chassis serial number of the system. |
| 1.3.6.1.4.1.26866.2.9 | ScalarbladeSerialNumbers | read-only | current | Displays the blade serial numbers in the system. |
| 1.3.6.1.4.1.26866.2.10 | ScalarfirmwareVersion | read-only | current | Displays the firmware version of the system. |
| 1.3.6.1.4.1.26866.2.11 | ScalarhardwareVersion | read-only | current | Displays the hardware version of the system. |
| 1.3.6.1.4.1.26866.2.12 | ScalarcpuRAMSize | read-only | current | Displays the CPU RAM size of the system. |
| 1.3.6.1.4.1.26866.2.13 | ScalarcpuUtilization | read-only | current | Displays the CPU utilization of the system. |
| 1.3.6.1.4.1.26866.2.14 | Scalarfans | read-only | current | Displays the fans in the system. |
| 1.3.6.1.4.1.26866.2.15 | ScalartemperatureSensors | read-only | current | Displays the temperature sensors in the system. |
| 1.3.6.1.4.1.26866.2.16 | ScalarpowerSupply | read-only | current | Displays the power supplies in the system. |
| 1.3.6.1.4.1.26866.3 | NodegigamonProducts | |||
| 1.3.6.1.4.1.26866.3.1 | NodegigamonGV2404 | |||
| 1.3.6.1.4.1.26866.3.2 | NodegigamonGV420 | |||
| 1.3.6.1.4.1.26866.3.3 | NodegigamonGV212 | |||
| 1.3.6.1.4.1.26866.3.4 | NodegigamonGV216 |