MIB Viewer

GUDEADS-ENC2302-MIB

54 objects
No module-level DESCRIPTION found.
Imported Objects
SNMPv2-CONFNOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.28507Identitygudeads
1.3.6.1.4.1.28507.70NodegadsENC2302
1.3.6.1.4.1.28507.70.1Nodeenc2302Objects
1.3.6.1.4.1.28507.70.1.1Nodeenc2302CommonConfig
1.3.6.1.4.1.28507.70.1.1.1Nodeenc2302SNMPaccess
1.3.6.1.4.1.28507.70.1.1.1.1Scalarenc2302TrapCtrlread-writecurrent0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3
1.3.6.1.4.1.28507.70.1.1.1.2Tableenc2302TrapIPTablenot-accessiblecurrentlist of all Trap receiver
1.3.6.1.4.1.28507.70.1.1.1.2.1Rowenc2302TrapIPEntrynot-accessiblecurrentan entry containing management informations regarding the list of trap receivers
1.3.6.1.4.1.28507.70.1.1.1.2.1.1Columnenc2302TrapIPIndexread-onlycurrentA unique value, greater than zero, for each receiver slot.
1.3.6.1.4.1.28507.70.1.1.1.2.1.2Columnenc2302TrapAddrread-writecurrentDNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot.
1.3.6.1.4.1.28507.70.1.2Nodeenc2302DeviceConfig
1.3.6.1.4.1.28507.70.1.3Nodeenc2302IntActors
1.3.6.1.4.1.28507.70.1.3.1Nodeenc2302relayports
1.3.6.1.4.1.28507.70.1.3.1.1Scalarenc2302portNumberread-onlycurrentThe number of Relay Ports
1.3.6.1.4.1.28507.70.1.3.1.2Tableenc2302portTablenot-accessiblecurrentlist of all EPC Relay Ports
1.3.6.1.4.1.28507.70.1.3.1.2.1Rowenc2302portEntrynot-accessiblecurrentAn entry containing management information applicable to a particular relay port.
1.3.6.1.4.1.28507.70.1.3.1.2.1.1Columnenc2302PortIndexread-onlycurrentA unique value, greater than zero, for each Relay Port.
1.3.6.1.4.1.28507.70.1.3.1.2.1.2Columnenc2302PortNameread-writecurrentA textual string containing name of a Relay Port.
1.3.6.1.4.1.28507.70.1.3.1.2.1.3Columnenc2302PortStateread-writecurrentcurrent state a Relay Port
1.3.6.1.4.1.28507.70.1.3.1.2.1.4Columnenc2302PortSwitchCountread-onlycurrentThe total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches a…
1.3.6.1.4.1.28507.70.1.3.1.2.1.5Columnenc2302PortStartupModeread-writecurrentset Mode of startup sequence (off, on , remember last state)
1.3.6.1.4.1.28507.70.1.3.1.2.1.6Columnenc2302PortStartupDelayread-writecurrentDelay in sec for startup action
1.3.6.1.4.1.28507.70.1.3.1.2.1.7Columnenc2302PortRepowerTimeread-writecurrentDelay in sec for repower port after switching off
1.3.6.1.4.1.28507.70.1.4Nodeenc2302ExtActors
1.3.6.1.4.1.28507.70.1.5Nodeenc2302IntSensors
1.3.6.1.4.1.28507.70.1.5.6Nodeenc2302Inputs
1.3.6.1.4.1.28507.70.1.5.6.1Scalarenc2302ActiveInputsread-onlycurrentNumber of suppported Input Channels.
1.3.6.1.4.1.28507.70.1.5.6.2Tableenc2302InputTablenot-accessiblecurrent
1.3.6.1.4.1.28507.70.1.5.6.2.1Rowenc2302InputEntrynot-accessiblecurrent
1.3.6.1.4.1.28507.70.1.5.6.2.1.1Columnenc2302InputIndexread-onlycurrent
1.3.6.1.4.1.28507.70.1.5.6.2.1.2Columnenc2302Inputread-onlycurrentInput state of device
1.3.6.1.4.1.28507.70.1.6Nodeenc2302ExtSensors
1.3.6.1.4.1.28507.70.1.6.1Tableenc2302SensorTablenot-accessiblecurrent
1.3.6.1.4.1.28507.70.1.6.1.1Rowenc2302SensorEntrynot-accessiblecurrent
1.3.6.1.4.1.28507.70.1.6.1.1.1Columnenc2302SensorIndexread-onlycurrent
1.3.6.1.4.1.28507.70.1.6.1.1.2Columnenc2302TempSensorread-onlycurrentactual temperature
1.3.6.1.4.1.28507.70.1.6.1.1.3Columnenc2302HygroSensorread-onlycurrentactual humidity
1.3.6.1.4.1.28507.70.1.6.1.1.4Columnenc2302InputSensorread-onlycurrentlogical state of input sensor
1.3.6.1.4.1.28507.70.1.6.1.1.5Columnenc2302AirPressureread-onlycurrentactual air pressure
1.3.6.1.4.1.28507.70.1.6.1.1.6Columnenc2302DewPointread-onlycurrentdew point for actual temperature and humidity
1.3.6.1.4.1.28507.70.1.6.1.1.7Columnenc2302DewPointDiffread-onlycurrentdifference between dew point and actual temperature (Temp - DewPoint)
1.3.6.1.4.1.28507.70.2Nodeenc2302Conf
1.3.6.1.4.1.28507.70.2.1Nodeenc2302Groups
1.3.6.1.4.1.28507.70.2.1.1Groupenc2302BasicGroupcurrentBasic objects.
1.3.6.1.4.1.28507.70.2.1.2Groupenc2302NotificationGroupcurrent
1.3.6.1.4.1.28507.70.2.2Nodeenc2302Compls
1.3.6.1.4.1.28507.70.3Nodeevents
1.3.6.1.4.1.28507.70.3.1Notificationenc2302SwitchEvtPortcurrentEvent is triggered when a port is switched
1.3.6.1.4.1.28507.70.3.2Notificationenc2302InputEvtcurrentChange of device input.
1.3.6.1.4.1.28507.70.3.3Notificationenc2302TempEvtSencurrenttemperature limits exceeded
1.3.6.1.4.1.28507.70.3.4Notificationenc2302HygroEvtSencurrenthygro limits exceeded
1.3.6.1.4.1.28507.70.3.5Notificationenc2302InputEvtSencurrentchange of logical input sensor state
1.3.6.1.4.1.28507.70.3.6Notificationenc2302AirPressureEvtSencurrentAir Pressure limits exceeded
1.3.6.1.4.1.28507.70.3.7Notificationenc2302DewPtDiffEvtSencurrentDew Point Difference limits exceeded