MIB Viewer

GUDEADS-EPC1292-MIB

80 objects
No module-level DESCRIPTION found.
Imported Objects
SNMPv2-CONFNOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises Gauge32 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.28507Identitygudeads
1.3.6.1.4.1.28507.50NodegadsEPC1292
1.3.6.1.4.1.28507.50.1Nodeepc1292Objects
1.3.6.1.4.1.28507.50.1.1Nodeepc1292CommonConfig
1.3.6.1.4.1.28507.50.1.1.1Nodeepc1292SNMPaccess
1.3.6.1.4.1.28507.50.1.1.1.1Scalarepc1292TrapCtrlread-writecurrent0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3
1.3.6.1.4.1.28507.50.1.1.1.2Tableepc1292TrapIPTablenot-accessiblecurrentlist of all Trap receiver
1.3.6.1.4.1.28507.50.1.1.1.2.1Rowepc1292TrapIPEntrynot-accessiblecurrentan entry containing management informations regarding the list of trap receivers
1.3.6.1.4.1.28507.50.1.1.1.2.1.1Columnepc1292TrapIPIndexread-onlycurrentA unique value, greater than zero, for each receiver slot.
1.3.6.1.4.1.28507.50.1.1.1.2.1.2Columnepc1292TrapAddrread-writecurrentDNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot.
1.3.6.1.4.1.28507.50.1.2Nodeepc1292DeviceConfig
1.3.6.1.4.1.28507.50.1.3Nodeepc1292IntActors
1.3.6.1.4.1.28507.50.1.3.1Nodeepc1292relayports
1.3.6.1.4.1.28507.50.1.3.1.1Scalarepc1292portNumberread-onlycurrentThe number of Relay Ports
1.3.6.1.4.1.28507.50.1.3.1.2Tableepc1292portTablenot-accessiblecurrentlist of all EPC Relay Ports
1.3.6.1.4.1.28507.50.1.3.1.2.1Rowepc1292portEntrynot-accessiblecurrentAn entry containing management information applicable to a particular relay port.
1.3.6.1.4.1.28507.50.1.3.1.2.1.1Columnepc1292PortIndexread-onlycurrentA unique value, greater than zero, for each Relay Port.
1.3.6.1.4.1.28507.50.1.3.1.2.1.2Columnepc1292PortNameread-writecurrentA textual string containing name of a Relay Port.
1.3.6.1.4.1.28507.50.1.3.1.2.1.3Columnepc1292PortStateread-writecurrentcurrent state of a Relay Port
1.3.6.1.4.1.28507.50.1.3.1.2.1.4Columnepc1292PortSwitchCountread-onlycurrentThe total number of switch actions ocurred on a Relay Port. Does not count switch commands which will not switch the ralay state, so just real relay switches a…
1.3.6.1.4.1.28507.50.1.3.1.2.1.5Columnepc1292PortStartupModeread-writecurrentset Mode of startup sequence (off, on , remember last state)
1.3.6.1.4.1.28507.50.1.3.1.2.1.6Columnepc1292PortStartupDelayread-writecurrentDelay in sec for startup action
1.3.6.1.4.1.28507.50.1.3.1.2.1.7Columnepc1292PortRepowerTimeread-writecurrentDelay in sec for repower port after switching off
1.3.6.1.4.1.28507.50.1.4Nodeepc1292ExtActors
1.3.6.1.4.1.28507.50.1.5Nodeepc1292IntSensors
1.3.6.1.4.1.28507.50.1.5.1Nodeepc1292PowerChan
1.3.6.1.4.1.28507.50.1.5.1.1Scalarepc1292ActivePowerChanread-onlycurrentNumber of suppported Power Channels.
1.3.6.1.4.1.28507.50.1.5.1.2Tableepc1292PowerTablenot-accessiblecurrentAll available Channel Interfaces.
1.3.6.1.4.1.28507.50.1.5.1.2.1Rowepc1292PowerEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Power Channel.
1.3.6.1.4.1.28507.50.1.5.1.2.1.1Columnepc1292PowerIndexread-onlycurrentIndex of Power Channel entries
1.3.6.1.4.1.28507.50.1.5.1.2.1.2Columnepc1292ChanStatusread-onlycurrent0 = data not active, 1 = data valid
1.3.6.1.4.1.28507.50.1.5.1.2.1.3Columnepc1292AbsEnergyActiveread-onlycurrentAbsolute Active Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.4Columnepc1292PowerActiveread-onlycurrentActive Power
1.3.6.1.4.1.28507.50.1.5.1.2.1.5Columnepc1292Currentread-onlycurrentActual Curent on Power Channel.
1.3.6.1.4.1.28507.50.1.5.1.2.1.6Columnepc1292Voltageread-onlycurrentActual Voltage on Power Channel
1.3.6.1.4.1.28507.50.1.5.1.2.1.7Columnepc1292Frequencyread-onlycurrentFrequency of Power Channel
1.3.6.1.4.1.28507.50.1.5.1.2.1.8Columnepc1292PowerFactorread-onlycurrentPower Factor of Channel between -1.0 and 1.00
1.3.6.1.4.1.28507.50.1.5.1.2.1.9Columnepc1292Pangleread-onlycurrentPhase Angle between Voltage and L Line Current between -180.0 and 180.0
1.3.6.1.4.1.28507.50.1.5.1.2.1.10Columnepc1292PowerApparentread-onlycurrentL Line Mean Apparent Power
1.3.6.1.4.1.28507.50.1.5.1.2.1.11Columnepc1292PowerReactiveread-onlycurrentL Line Mean Reactive Power
1.3.6.1.4.1.28507.50.1.5.1.2.1.12Columnepc1292AbsEnergyReactiveread-onlycurrentAbsolute Reactive Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.13Columnepc1292AbsEnergyActiveResettableread-writecurrentResettable Absolute Active Energy counter. Writing '0' resets all resettable counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.14Columnepc1292AbsEnergyReactiveResettableread-onlycurrentResettable Absolute Reactive Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.15Columnepc1292ResetTimeread-onlycurrentTime in seconds since last Energy Counter reset.
1.3.6.1.4.1.28507.50.1.5.1.2.1.16Columnepc1292ForwEnergyActiveread-onlycurrentForward Active Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.17Columnepc1292ForwEnergyReactiveread-onlycurrentForward Reactive Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.18Columnepc1292ForwEnergyActiveResettableread-onlycurrentResettable Forward Active Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.19Columnepc1292ForwEnergyReactiveResettableread-onlycurrentResettable Forward Reactive Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.20Columnepc1292RevEnergyActiveread-onlycurrentReverse Active Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.21Columnepc1292RevEnergyReactiveread-onlycurrentReverse Reactive Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.22Columnepc1292RevEnergyActiveResettableread-onlycurrentResettable Reverse Active Energy counter.
1.3.6.1.4.1.28507.50.1.5.1.2.1.23Columnepc1292RevEnergyReactiveResettableread-onlycurrentResettable Reverse Reactive Energy counter.
1.3.6.1.4.1.28507.50.1.5.2Tableepc1292OVPTablenot-accessiblecurrentOvervoltage Protection Table
1.3.6.1.4.1.28507.50.1.5.2.1Rowepc1292OVPEntrynot-accessiblecurrent
1.3.6.1.4.1.28507.50.1.5.2.1.1Columnepc1292OVPIndexread-onlycurrent
1.3.6.1.4.1.28507.50.1.5.2.1.2Columnepc1292OVPStatusread-onlycurrentshows the status of the built-in Overvoltage Protection
1.3.6.1.4.1.28507.50.1.6Nodeepc1292ExtSensors
1.3.6.1.4.1.28507.50.1.6.1Tableepc1292SensorTablenot-accessiblecurrent
1.3.6.1.4.1.28507.50.1.6.1.1Rowepc1292SensorEntrynot-accessiblecurrent
1.3.6.1.4.1.28507.50.1.6.1.1.1Columnepc1292SensorIndexread-onlycurrent
1.3.6.1.4.1.28507.50.1.6.1.1.2Columnepc1292TempSensorread-onlycurrentactual temperature
1.3.6.1.4.1.28507.50.1.6.1.1.3Columnepc1292HygroSensorread-onlycurrentactual humidity
1.3.6.1.4.1.28507.50.1.6.1.1.4Columnepc1292InputSensorread-onlycurrentlogical state of input sensor
1.3.6.1.4.1.28507.50.1.6.1.1.5Columnepc1292AirPressureread-onlycurrentactual air pressure
1.3.6.1.4.1.28507.50.1.6.1.1.6Columnepc1292DewPointread-onlycurrentdew point for actual temperature and humidity
1.3.6.1.4.1.28507.50.1.6.1.1.7Columnepc1292DewPointDiffread-onlycurrentdifference between dew point and actual temperature (Temp - DewPoint)
1.3.6.1.4.1.28507.50.2Nodeepc1292Conf
1.3.6.1.4.1.28507.50.2.1Nodeepc1292Groups
1.3.6.1.4.1.28507.50.2.1.1Groupepc1292BasicGroupcurrentBasic objects.
1.3.6.1.4.1.28507.50.2.1.2Groupepc1292NotificationGroupcurrent
1.3.6.1.4.1.28507.50.2.2Nodeepc1292Compls
1.3.6.1.4.1.28507.50.3Nodeevents
1.3.6.1.4.1.28507.50.3.1Notificationepc1292SwitchEvtPortcurrentEvent is triggered when a port is switched
1.3.6.1.4.1.28507.50.3.2Notificationepc1292TempEvtSencurrenttemperature limits exceeded
1.3.6.1.4.1.28507.50.3.3Notificationepc1292HygroEvtSencurrenthygro limits exceeded
1.3.6.1.4.1.28507.50.3.4Notificationepc1292InputEvtSencurrentchange of logical input sensor state
1.3.6.1.4.1.28507.50.3.5Notificationepc1292AirPressureEvtSencurrentAir Pressure limits exceeded
1.3.6.1.4.1.28507.50.3.6Notificationepc1292DewPtDiffEvtSencurrentDew Point Difference limits exceeded
1.3.6.1.4.1.28507.50.3.7Notificationepc1292OVPEvtcurrentEvent is triggered when the OVP status changes
1.3.6.1.4.1.28507.50.3.8Notificationepc1292LineAmperageEvtcurrentEvent is triggered when a measured current is crossing the entered limits