MIB Viewer

GUDEADS-PDU8340-MIB

65 objects
No module-level DESCRIPTION found.
Imported Objects
SNMPv2-CONFNOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.28507Identitygudeads
1.3.6.1.4.1.28507.54NodegadsPDU8340
1.3.6.1.4.1.28507.54.1Nodepdu8340Objects
1.3.6.1.4.1.28507.54.1.1Nodepdu8340CommonConfig
1.3.6.1.4.1.28507.54.1.1.1Nodepdu8340SNMPaccess
1.3.6.1.4.1.28507.54.1.1.1.1Scalarpdu8340TrapCtrlread-writecurrent0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3
1.3.6.1.4.1.28507.54.1.1.1.2Tablepdu8340TrapIPTablenot-accessiblecurrentlist of all Trap receiver
1.3.6.1.4.1.28507.54.1.1.1.2.1Rowpdu8340TrapIPEntrynot-accessiblecurrentan entry containing management informations regarding the list of trap receivers
1.3.6.1.4.1.28507.54.1.1.1.2.1.1Columnpdu8340TrapIPIndexread-onlycurrentA unique value, greater than zero, for each receiver slot.
1.3.6.1.4.1.28507.54.1.1.1.2.1.2Columnpdu8340TrapAddrread-writecurrentDNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot.
1.3.6.1.4.1.28507.54.1.2Nodepdu8340DeviceConfig
1.3.6.1.4.1.28507.54.1.3Nodepdu8340IntActors
1.3.6.1.4.1.28507.54.1.3.10Scalarpdu8340Buzzerread-writecurrentturn Buzzer on and off
1.3.6.1.4.1.28507.54.1.4Nodepdu8340ExtActors
1.3.6.1.4.1.28507.54.1.5Nodepdu8340IntSensors
1.3.6.1.4.1.28507.54.1.5.1Nodepdu8340PowerChan
1.3.6.1.4.1.28507.54.1.5.1.1Scalarpdu8340ActivePowerChanread-onlycurrentNumber of suppported Power Channels.
1.3.6.1.4.1.28507.54.1.5.1.2Tablepdu8340PowerTablenot-accessiblecurrentAll available Channel Interfaces.
1.3.6.1.4.1.28507.54.1.5.1.2.1Rowpdu8340PowerEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Power Channel.
1.3.6.1.4.1.28507.54.1.5.1.2.1.1Columnpdu8340PowerIndexread-onlycurrentIndex of Power Channel entries
1.3.6.1.4.1.28507.54.1.5.1.2.1.2Columnpdu8340ChanStatusread-onlycurrent0 = data not active, 1 = data valid
1.3.6.1.4.1.28507.54.1.5.1.2.1.3Columnpdu8340AbsEnergyActiveread-onlycurrentAbsolute Active Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.4Columnpdu8340PowerActiveread-onlycurrentActive Power
1.3.6.1.4.1.28507.54.1.5.1.2.1.5Columnpdu8340Currentread-onlycurrentActual Current on Power Channel.
1.3.6.1.4.1.28507.54.1.5.1.2.1.6Columnpdu8340Voltageread-onlycurrentActual Voltage on Power Channel
1.3.6.1.4.1.28507.54.1.5.1.2.1.7Columnpdu8340Frequencyread-onlycurrentFrequency of Power Channel
1.3.6.1.4.1.28507.54.1.5.1.2.1.8Columnpdu8340PowerFactorread-onlycurrentPower Factor of Channel between -1.0 and 1.00
1.3.6.1.4.1.28507.54.1.5.1.2.1.9Columnpdu8340Pangleread-onlycurrentPhase Angle between Voltage and L Line Current between -180.0 and 180.0
1.3.6.1.4.1.28507.54.1.5.1.2.1.10Columnpdu8340PowerApparentread-onlycurrentL Line Mean Apparent Power
1.3.6.1.4.1.28507.54.1.5.1.2.1.11Columnpdu8340PowerReactiveread-onlycurrentL Line Mean Reactive Power
1.3.6.1.4.1.28507.54.1.5.1.2.1.12Columnpdu8340AbsEnergyReactiveread-onlycurrentAbsolute Reactive Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.13Columnpdu8340AbsEnergyActiveResettableread-writecurrentResettable Absolute Active Energy counter. Writing '0' resets all resettable counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.14Columnpdu8340AbsEnergyReactiveResettableread-onlycurrentResettable Absolute Reactive Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.15Columnpdu8340ResetTimeread-onlycurrentTime in seconds since last Energy Counter reset.
1.3.6.1.4.1.28507.54.1.5.1.2.1.16Columnpdu8340ForwEnergyActiveread-onlycurrentForward Active Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.17Columnpdu8340ForwEnergyReactiveread-onlycurrentForward Reactive Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.18Columnpdu8340ForwEnergyActiveResettableread-onlycurrentResettable Forward Active Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.19Columnpdu8340ForwEnergyReactiveResettableread-onlycurrentResettable Forward Reactive Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.20Columnpdu8340RevEnergyActiveread-onlycurrentReverse Active Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.21Columnpdu8340RevEnergyReactiveread-onlycurrentReverse Reactive Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.22Columnpdu8340RevEnergyActiveResettableread-onlycurrentResettable Reverse Active Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.23Columnpdu8340RevEnergyReactiveResettableread-onlycurrentResettable Reverse Reactive Energy counter.
1.3.6.1.4.1.28507.54.1.5.1.2.1.24Columnpdu8340ResidualCurrentread-onlycurrentActual Residual Current on Power Channel. According Typ A IEC 60755. Only visible on models that support this feature.
1.3.6.1.4.1.28507.54.1.6Nodepdu8340ExtSensors
1.3.6.1.4.1.28507.54.1.6.1Tablepdu8340SensorTablenot-accessiblecurrent
1.3.6.1.4.1.28507.54.1.6.1.1Rowpdu8340SensorEntrynot-accessiblecurrent
1.3.6.1.4.1.28507.54.1.6.1.1.1Columnpdu8340SensorIndexread-onlycurrent
1.3.6.1.4.1.28507.54.1.6.1.1.2Columnpdu8340TempSensorread-onlycurrentactual temperature
1.3.6.1.4.1.28507.54.1.6.1.1.3Columnpdu8340HygroSensorread-onlycurrentactual humidity
1.3.6.1.4.1.28507.54.1.6.1.1.4Columnpdu8340InputSensorread-onlycurrentlogical state of input sensor
1.3.6.1.4.1.28507.54.1.6.1.1.5Columnpdu8340AirPressureread-onlycurrentactual air pressure
1.3.6.1.4.1.28507.54.1.6.1.1.6Columnpdu8340DewPointread-onlycurrentdew point for actual temperature and humidity
1.3.6.1.4.1.28507.54.1.6.1.1.7Columnpdu8340DewPointDiffread-onlycurrentdifference between dew point and actual temperature (Temp - DewPoint)
1.3.6.1.4.1.28507.54.2Nodepdu8340Conf
1.3.6.1.4.1.28507.54.2.1Nodepdu8340Groups
1.3.6.1.4.1.28507.54.2.1.1Grouppdu8340BasicGroupcurrentBasic objects.
1.3.6.1.4.1.28507.54.2.1.2Grouppdu8340NotificationGroupcurrent
1.3.6.1.4.1.28507.54.2.2Nodepdu8340Compls
1.3.6.1.4.1.28507.54.3Nodeevents
1.3.6.1.4.1.28507.54.3.1Notificationpdu8340TempEvtSencurrenttemperature limits exceeded
1.3.6.1.4.1.28507.54.3.2Notificationpdu8340HygroEvtSencurrenthygro limits exceeded
1.3.6.1.4.1.28507.54.3.3Notificationpdu8340InputEvtSencurrentchange of logical input sensor state
1.3.6.1.4.1.28507.54.3.4Notificationpdu8340AirPressureEvtSencurrentAir Pressure limits exceeded
1.3.6.1.4.1.28507.54.3.5Notificationpdu8340DewPtDiffEvtSencurrentDew Point Difference limits exceeded
1.3.6.1.4.1.28507.54.3.6Notificationpdu8340LineAmperageEvtcurrentEvent is triggered when a measured current is crossing the entered limits