MIB Viewer

GUDEADS-PDU8341-MIB

65 objects
No module-level DESCRIPTION found.
Imported Objects
SNMPv2-CONFNOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
OIDNameAccessStatusDescription
1.3.6.1.4.1.28507Identitygudeads
1.3.6.1.4.1.28507.65NodegadsPDU8341
1.3.6.1.4.1.28507.65.1Nodepdu8341Objects
1.3.6.1.4.1.28507.65.1.1Nodepdu8341CommonConfig
1.3.6.1.4.1.28507.65.1.1.1Nodepdu8341SNMPaccess
1.3.6.1.4.1.28507.65.1.1.1.1Scalarpdu8341TrapCtrlread-writecurrent0 = off 1 = Ver. 1 2 = Ver. 2c 3 = Ver. 3
1.3.6.1.4.1.28507.65.1.1.1.2Tablepdu8341TrapIPTablenot-accessiblecurrentlist of all Trap receiver
1.3.6.1.4.1.28507.65.1.1.1.2.1Rowpdu8341TrapIPEntrynot-accessiblecurrentan entry containing management informations regarding the list of trap receivers
1.3.6.1.4.1.28507.65.1.1.1.2.1.1Columnpdu8341TrapIPIndexread-onlycurrentA unique value, greater than zero, for each receiver slot.
1.3.6.1.4.1.28507.65.1.1.1.2.1.2Columnpdu8341TrapAddrread-writecurrentDNS name or IP address specifying one Trap receiver slot. A port can optionally be specified: 'name:port' An empty string disables this slot.
1.3.6.1.4.1.28507.65.1.2Nodepdu8341DeviceConfig
1.3.6.1.4.1.28507.65.1.3Nodepdu8341IntActors
1.3.6.1.4.1.28507.65.1.3.10Scalarpdu8341Buzzerread-writecurrentturn Buzzer on and off
1.3.6.1.4.1.28507.65.1.4Nodepdu8341ExtActors
1.3.6.1.4.1.28507.65.1.5Nodepdu8341IntSensors
1.3.6.1.4.1.28507.65.1.5.1Nodepdu8341PowerChan
1.3.6.1.4.1.28507.65.1.5.1.1Scalarpdu8341ActivePowerChanread-onlycurrentNumber of suppported Power Channels.
1.3.6.1.4.1.28507.65.1.5.1.2Tablepdu8341PowerTablenot-accessiblecurrentAll available Channel Interfaces.
1.3.6.1.4.1.28507.65.1.5.1.2.1Rowpdu8341PowerEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Power Channel.
1.3.6.1.4.1.28507.65.1.5.1.2.1.1Columnpdu8341PowerIndexread-onlycurrentIndex of Power Channel entries
1.3.6.1.4.1.28507.65.1.5.1.2.1.2Columnpdu8341ChanStatusread-onlycurrent0 = data not active, 1 = data valid
1.3.6.1.4.1.28507.65.1.5.1.2.1.3Columnpdu8341AbsEnergyActiveread-onlycurrentAbsolute Active Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.4Columnpdu8341PowerActiveread-onlycurrentActive Power
1.3.6.1.4.1.28507.65.1.5.1.2.1.5Columnpdu8341Currentread-onlycurrentActual Current on Power Channel.
1.3.6.1.4.1.28507.65.1.5.1.2.1.6Columnpdu8341Voltageread-onlycurrentActual Voltage on Power Channel
1.3.6.1.4.1.28507.65.1.5.1.2.1.7Columnpdu8341Frequencyread-onlycurrentFrequency of Power Channel
1.3.6.1.4.1.28507.65.1.5.1.2.1.8Columnpdu8341PowerFactorread-onlycurrentPower Factor of Channel between -1.0 and 1.00
1.3.6.1.4.1.28507.65.1.5.1.2.1.9Columnpdu8341Pangleread-onlycurrentPhase Angle between Voltage and L Line Current between -180.0 and 180.0
1.3.6.1.4.1.28507.65.1.5.1.2.1.10Columnpdu8341PowerApparentread-onlycurrentL Line Mean Apparent Power
1.3.6.1.4.1.28507.65.1.5.1.2.1.11Columnpdu8341PowerReactiveread-onlycurrentL Line Mean Reactive Power
1.3.6.1.4.1.28507.65.1.5.1.2.1.12Columnpdu8341AbsEnergyReactiveread-onlycurrentAbsolute Reactive Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.13Columnpdu8341AbsEnergyActiveResettableread-writecurrentResettable Absolute Active Energy counter. Writing '0' resets all resettable counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.14Columnpdu8341AbsEnergyReactiveResettableread-onlycurrentResettable Absolute Reactive Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.15Columnpdu8341ResetTimeread-onlycurrentTime in seconds since last Energy Counter reset.
1.3.6.1.4.1.28507.65.1.5.1.2.1.16Columnpdu8341ForwEnergyActiveread-onlycurrentForward Active Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.17Columnpdu8341ForwEnergyReactiveread-onlycurrentForward Reactive Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.18Columnpdu8341ForwEnergyActiveResettableread-onlycurrentResettable Forward Active Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.19Columnpdu8341ForwEnergyReactiveResettableread-onlycurrentResettable Forward Reactive Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.20Columnpdu8341RevEnergyActiveread-onlycurrentReverse Active Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.21Columnpdu8341RevEnergyReactiveread-onlycurrentReverse Reactive Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.22Columnpdu8341RevEnergyActiveResettableread-onlycurrentResettable Reverse Active Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.23Columnpdu8341RevEnergyReactiveResettableread-onlycurrentResettable Reverse Reactive Energy counter.
1.3.6.1.4.1.28507.65.1.5.1.2.1.24Columnpdu8341ResidualCurrentread-onlycurrentActual Residual Current on Power Channel. According Typ A IEC 60755. Only visible on models that support this feature.
1.3.6.1.4.1.28507.65.1.6Nodepdu8341ExtSensors
1.3.6.1.4.1.28507.65.1.6.1Tablepdu8341SensorTablenot-accessiblecurrent
1.3.6.1.4.1.28507.65.1.6.1.1Rowpdu8341SensorEntrynot-accessiblecurrent
1.3.6.1.4.1.28507.65.1.6.1.1.1Columnpdu8341SensorIndexread-onlycurrent
1.3.6.1.4.1.28507.65.1.6.1.1.2Columnpdu8341TempSensorread-onlycurrentactual temperature
1.3.6.1.4.1.28507.65.1.6.1.1.3Columnpdu8341HygroSensorread-onlycurrentactual humidity
1.3.6.1.4.1.28507.65.1.6.1.1.4Columnpdu8341InputSensorread-onlycurrentlogical state of input sensor
1.3.6.1.4.1.28507.65.1.6.1.1.5Columnpdu8341AirPressureread-onlycurrentactual air pressure
1.3.6.1.4.1.28507.65.1.6.1.1.6Columnpdu8341DewPointread-onlycurrentdew point for actual temperature and humidity
1.3.6.1.4.1.28507.65.1.6.1.1.7Columnpdu8341DewPointDiffread-onlycurrentdifference between dew point and actual temperature (Temp - DewPoint)
1.3.6.1.4.1.28507.65.2Nodepdu8341Conf
1.3.6.1.4.1.28507.65.2.1Nodepdu8341Groups
1.3.6.1.4.1.28507.65.2.1.1Grouppdu8341BasicGroupcurrentBasic objects.
1.3.6.1.4.1.28507.65.2.1.2Grouppdu8341NotificationGroupcurrent
1.3.6.1.4.1.28507.65.2.2Nodepdu8341Compls
1.3.6.1.4.1.28507.65.3Nodeevents
1.3.6.1.4.1.28507.65.3.1Notificationpdu8341TempEvtSencurrenttemperature limits exceeded
1.3.6.1.4.1.28507.65.3.2Notificationpdu8341HygroEvtSencurrenthygro limits exceeded
1.3.6.1.4.1.28507.65.3.3Notificationpdu8341InputEvtSencurrentchange of logical input sensor state
1.3.6.1.4.1.28507.65.3.4Notificationpdu8341AirPressureEvtSencurrentAir Pressure limits exceeded
1.3.6.1.4.1.28507.65.3.5Notificationpdu8341DewPtDiffEvtSencurrentDew Point Difference limits exceeded
1.3.6.1.4.1.28507.65.3.6Notificationpdu8341LineAmperageEvtcurrentEvent is triggered when a measured current is crossing the entered limits