MIB Viewer

H3C-HPEOC-MIB

40 objects
The objects in this MIB module are used to manage and display current configuration of Ethernet Over Cable Network (EOC) which based on HomePlug(HP) AV Specification.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.10.2.84Identityh3cHPEOCThe objects in this MIB module are used to manage and display current configuration of Ethernet Over Cable Network (EOC) which based on HomePlug(HP) AV Specifi…
1.3.6.1.4.1.2011.10.2.84.1Nodeh3cHPEOCSystem
1.3.6.1.4.1.2011.10.2.84.1.1Scalarh3cHPEOCCltVlanTyperead-writecurrentControl EOC CLT's VLAN type, ieee8021q : 802.1q VLAN mode, portbased : portbased VLAN mode.
1.3.6.1.4.1.2011.10.2.84.1.2Tableh3cHPEOCCltVlanManTablenot-accessiblecurrentThis table implements the management of CLT(Coax Line Terminal) VLAN.
1.3.6.1.4.1.2011.10.2.84.1.2.1Rowh3cHPEOCCltVlanManEntrynot-accessiblecurrentThe entry of the table h3cHPEOCCltVlanManTable.
1.3.6.1.4.1.2011.10.2.84.1.2.1.1Columnh3cHPEOCCltEthPortTyperead-writecurrentControl CLT ethernet ports' type, normal : port which used for normal translation, debug : port which used for debug.
1.3.6.1.4.1.2011.10.2.84.1.3Tableh3cHPEOCCltSysManTablenot-accessiblecurrentThis table implements the management of CLT(Coax Line Terminal).
1.3.6.1.4.1.2011.10.2.84.1.3.1Rowh3cHPEOCCltSysManEntrynot-accessiblecurrentThe entry of the table h3cHPEOCCltSysManTable.
1.3.6.1.4.1.2011.10.2.84.1.3.1.1Columnh3cHPEOCCltDescrread-writecurrentSet the description of CLT.
1.3.6.1.4.1.2011.10.2.84.1.3.1.2Columnh3cHPEOCCltFwVersionread-onlycurrentEOC firmware version. If the object length is zero, it means the version is unknown.
1.3.6.1.4.1.2011.10.2.84.1.4Tableh3cHPEOCCnuSysManTablenot-accessiblecurrentThis table implements the management of CNUs.
1.3.6.1.4.1.2011.10.2.84.1.4.1Rowh3cHPEOCCnuSysManEntrynot-accessiblecurrentThe entry of the table h3cHPEOCCnuSysManTable.
1.3.6.1.4.1.2011.10.2.84.1.4.1.1Columnh3cHPEOCCnuBcastControlread-writecurrentBroadcast storm suppression status. true(1) - Broadcast storm suppression enable. false(2) - Broadcast storm suppression disable.
1.3.6.1.4.1.2011.10.2.84.1.4.1.2Columnh3cHPEOCCnuAnonymStatusread-onlycurrentAnonymity status. true(1) - the user which uses the CNU is anonymous. false(2) - the user which uses the CNU has an account.
1.3.6.1.4.1.2011.10.2.84.1.4.1.3Columnh3cHPEOCCnuMacLimitread-writecurrentConfigure the max number of MAC address entries which can access through the CNU, it ranges from 1 to 8. Otherwise, If configure 0, the CNU won't limit the MAC…
1.3.6.1.4.1.2011.10.2.84.1.5Scalarh3cHPEOCCltAutoUpgraderead-writecurrentAuto upgrade Status. true(1) - The firmware of the CNU will be auto changed by CLT. false(2)- The firmware of the CNU will not be auto changed.
1.3.6.1.4.1.2011.10.2.84.1.6Scalarh3cHPEOCOnLineCnuNumberread-onlycurrentThe total number of the online CNU(s).
1.3.6.1.4.1.2011.10.2.84.1.7Scalarh3cHPEOCCpuMacAddressread-onlycurrentEOC CPU's MAC address.
1.3.6.1.4.1.2011.10.2.84.1.8Scalarh3cHPEOCOffLineCnuNumberread-onlycurrentThe total number of the offline CNU(s).
1.3.6.1.4.1.2011.10.2.84.1.9Scalarh3cHPEOCDownLoadCNUFWResultaccessible-for-notifycurrentDownload CNU firmware result.
1.3.6.1.4.1.2011.10.2.84.1.10Scalarh3cHPEOCCltAutoUpgradeTyperead-writecurrentType of auto upgrade status. It depends on h3cHPEOCCltAutoUpgrade status. flash - The CLT auto upgrade the firmware inside its flash to the CNUs. ftp - First d…
1.3.6.1.4.1.2011.10.2.84.1.11Nodeh3cHPEOCAutoUpObjects
1.3.6.1.4.1.2011.10.2.84.1.11.1Scalarh3cHPEOCServerAddressread-writecurrentThe address of remote host acting as server for operation. The default value is 0.0.0.0
1.3.6.1.4.1.2011.10.2.84.1.11.2Scalarh3cHPEOCServerUserread-writecurrentWhen using ftp to transfer files, the user name must be specified through this node. It contains 1 to 30 characters.
1.3.6.1.4.1.2011.10.2.84.1.11.3Scalarh3cHPEOCServerPasswordread-writecurrentRemote user password for copying via ftp protocol. Optionally, this object may be ignored for protocols other than ftp. It contains 1 to 31 characters.
1.3.6.1.4.1.2011.10.2.84.2Nodeh3cHPEOCCableInfo
1.3.6.1.4.1.2011.10.2.84.2.1Tableh3cHPEOCCableInfoTablenot-accessiblecurrentThis table defines the primary parameters of the cable information.
1.3.6.1.4.1.2011.10.2.84.2.1.1Rowh3cHPEOCCableInfoEntrynot-accessiblecurrentThe entry of the table h3cHPEOCCableInfoTable.
1.3.6.1.4.1.2011.10.2.84.2.1.1.1Columnh3cHPEOCFECErrorsread-onlycurrentThe cable port's FEC bits errors ratio. FEC means the payload Forward Error Correction. It's a technology of controlling errors. Packets in transmission is che…
1.3.6.1.4.1.2011.10.2.84.2.1.1.2Columnh3cHPEOCAvgBitsPerCarrierread-onlycurrentThe cable port's average bits per carrier.
1.3.6.1.4.1.2011.10.2.84.2.1.1.3Columnh3cHPEOCAvgSNRPerCarrierread-onlycurrentThe cable port's signal noise ratio(SNR) bits per carrier.
1.3.6.1.4.1.2011.10.2.84.2.1.1.4Columnh3cHPEOCAvgInPBCRCErrorsread-onlycurrentThe input PB CRC errors on average.
1.3.6.1.4.1.2011.10.2.84.2.1.1.5Columnh3cHPEOCInTotalPktsread-onlycurrentThe total number of packets(including bad packets) received on this interface.
1.3.6.1.4.1.2011.10.2.84.2.1.1.6Columnh3cHPEOCAvgOutPowerread-onlycurrentThe cable port's power sent on average, the unit is db.
1.3.6.1.4.1.2011.10.2.84.2.1.1.7Columnh3cHPEOCAvgOutPBCRCErrorsread-onlycurrentThe cable port's physical block(PB) cyclic redundancy check(CRC) errors sent on average.
1.3.6.1.4.1.2011.10.2.84.2.1.1.8Columnh3cHPEOCOutTotalPktsread-onlycurrentThe total count of the packets(including bad packets) sent on this interface.
1.3.6.1.4.1.2011.10.2.84.2.2Tableh3cHPEOCBitPerSymbolTablenot-accessiblecurrentThis table defines the bits per symbol parameters of the cable line.
1.3.6.1.4.1.2011.10.2.84.2.2.1Rowh3cHPEOCBitPerSymbolEntrynot-accessiblecurrentThe entry of the table h3cHPEOCBitPerSymbolTable.
1.3.6.1.4.1.2011.10.2.84.2.2.1.1Columnh3cHPEOCBitPerSymbolIndexnot-accessiblecurrentThe index of the h3cHPEOCBitPerSymbolTable.
1.3.6.1.4.1.2011.10.2.84.2.2.1.2Columnh3cHPEOCBitPerSymbolread-onlycurrenth3cHPEOCBitPerSymbol returns all the bits per symbol on the fixed frequency. Each 4 bits stand for one value, all the values picking-up will make up a cable bi…