H3C-STORAGE-MIB
91 objects
This MIB describes the general information of storage device, such as the property, configuration and management.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.10.10.1 | Identityh3cStorageMIB | This MIB describes the general information of storage device, such as the property, configuration and management. | ||
| 1.3.6.1.4.1.2011.10.10.1.1 | Nodeh3cStorageMibObjects | |||
| 1.3.6.1.4.1.2011.10.10.1.1.1 | Nodeh3cStorageServerInfo | |||
| 1.3.6.1.4.1.2011.10.10.1.1.1.1 | Nodeh3cStorageServerCapability | |||
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.1 | Scalarh3cRaidCapability | read-only | current | This object identifies if the agent support raid management. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.2 | Scalarh3cFcCapability | read-only | current | This object identifies if the agent support FC(fiber channel) management. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.3 | Scalarh3cNasCapability | read-only | current | This object identifies if the agent support NAS(Network Attached Storage). |
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.4 | Scalarh3cAdaptiveRepCapability | read-only | current | This object identifies if the agent support adaptive replication. With adaptive replication option, data from the primary resource is continuously replicated t… |
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.5 | Scalarh3cRemoteRepCapability | read-only | current | This object identifies if the agent support remote replication. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.6 | Scalarh3cSafeCacheCapability | read-only | current | This object identifies if the agent support safe cache. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.7 | Scalarh3cSyncMirrorCapability | read-only | current | This object identifies if the agent support synchronized mirror. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.8 | Scalarh3cAsyncMirrorCapability | read-only | current | This object identifies if the agent support asynchronous mirror. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.9 | Scalarh3cTimeMarkCapability | read-only | current | This object identifies if the agent support time mark. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.1.10 | Scalarh3cSseCapability | read-only | current | This object identifies if the agent support SSE(Storage Service Enable). |
| 1.3.6.1.4.1.2011.10.10.1.1.1.2 | Nodeh3cStorageTargetConfig | |||
| 1.3.6.1.4.1.2011.10.10.1.1.1.2.1 | Scalarh3ciSCSITargetEnable | read-write | current | This object identifies if the agent support iSCSI target. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.2.2 | Scalarh3cFcTargetEnable | read-write | current | This object identifies if the agent support FC target. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.3 | Nodeh3cStorageServerPhysInfo | |||
| 1.3.6.1.4.1.2011.10.10.1.1.1.3.1 | Scalarh3cServerLocationLedState | read-write | current | This object identifies the state of storage device's location led. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.3.2 | Scalarh3cServerResetButtonState | read-write | current | This object identifies if the reset button is enable. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.3.3 | Scalarh3cServerPowerButtonState | read-write | current | This object identifies if the power button is enable. |
| 1.3.6.1.4.1.2011.10.10.1.1.1.3.4 | Scalarh3cServerPowerState | read-only | current | This object identifies the state of power supply in the server, and is valid when UPS has been configured successful. The value 'online' means power supply is … |
| 1.3.6.1.4.1.2011.10.10.1.1.2 | Nodeh3cStoragePhysicalInfo | |||
| 1.3.6.1.4.1.2011.10.10.1.1.2.1 | Tableh3cDeuTable | not-accessible | current | This table contains some information of a particular DEU(Disk Enclosure Unit). |
| 1.3.6.1.4.1.2011.10.10.1.1.2.1.1 | Rowh3cDeuEntry | not-accessible | current | An entry containing management information applicable to a particular DEU. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.1.1.1 | Columnh3cDeuIndex | not-accessible | current | This object identifies the index of h3cDeuTable. The DEU identified by a particular value of this index is the same object as identified by the same value of e… |
| 1.3.6.1.4.1.2011.10.10.1.1.2.1.1.2 | Columnh3cDeuIDLed | read-write | current | This object identifies the state of storage DEU's led. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.1.1.3 | Columnh3cDeuDiskScan | read-write | current | The operation of scanning the table. When the value of this object is set to 'action', the operation of disk scanning is touched off. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.2 | Tableh3cStorageInterfaceTable | not-accessible | current | This table describes the interface information of the network. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.2.1 | Rowh3cStorageInterfaceEntry | not-accessible | current | An entry containing management information applicable to a particular interface. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.2.1.1 | Columnh3cStorageInterfaceIndex | not-accessible | current | This object identifies the index of H3cStorageInterfaceEntry. The interface identified by this index is the same interface as identified by the same value of i… |
| 1.3.6.1.4.1.2011.10.10.1.1.2.2.1.2 | Columnh3cStorageInterfaceGateway | read-write | current | This object identifies the gateway address of interface. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.2.1.3 | Columnh3cStorageInterfaceGatewayType | read-write | current | This object identifies the gateway address type of interface. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.2.1.4 | Columnh3cStorageInterfaceMTU | read-write | current | This object identifies the MTU of interface. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.3 | Tableh3cBondingTable | not-accessible | current | This table describes the information of the Bonding interface. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.3.1 | Rowh3cBondingEntry | not-accessible | current | An entry containing management information applicable to a particular Bonding interface. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.3.1.1 | Columnh3cBondingIndex | not-accessible | current | This object identifies the index of h3cBondingEntry. The interface identified by this index is the same interface as identified by the same value of ifIndex. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.3.1.2 | Columnh3cBondingPortList | read-write | current | An entry contains management information applicable to a particular bonding interface. Every two bytes describe the ifIndex of an interface, and an interface b… |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4 | Tableh3cScsiAdapterTable | not-accessible | current | This table containing some information of the SCSI(Small Computer System interface) adapter. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4.1 | Rowh3cScsiAdapterEntry | not-accessible | current | An entry containing management information applicable to a particular SCSI adapter. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4.1.1 | Columnh3cAdapterNumber | not-accessible | current | This object identifies the index of the adapter . |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4.1.2 | Columnh3cAdapterDesc | read-only | current | This object describes some information of the adapter. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4.1.3 | Columnh3cAdapterType | read-only | current | This object identifies the type of adapter. If the value of this object is not equal to 'fc', the associated object(such as h3cFcAdapterMode, h3cFcAdapterIWWPN… |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4.1.4 | Columnh3cFcAdapterMode | read-only | current | This object identifies the mode type of adapter. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4.1.5 | Columnh3cFcAdapterInitiatorWwpnName | read-only | current | This object describes the FC's adapter WWPN(World Wide Port Name) numbers. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4.1.6 | Columnh3cFcAdapterTargetWwpnName | read-only | current | This object describes the FC's target WWPN numbers. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4.1.7 | Columnh3cFcAdapterPortState | read-only | current | This object identifies the state of adapter's interface. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.4.1.8 | Columnh3cFcAdapterModeSwitch | read-write | current | This object identifies if the adapter work on a target mode. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5 | Tableh3cExtVoltageTable | not-accessible | current | This table contains some entity extend information of the voltage. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1 | Rowh3cExtVoltageEntry | not-accessible | current | An entry containing management information applicable to the voltage. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.1 | Columnh3cExtVoltagePhysicalIndex | accessible-for-notify | current | This object identifies the entity index of voltage. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.2 | Columnh3cExtVoltagePhysicalName | read-only | current | This object identifies the entity name of voltage. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.3 | Columnh3cExtVoltage | read-only | current | The voltage for the entity. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.4 | Columnh3cExtVoltageLowThreshold | read-write | current | The low-threshold for the voltage. When voltage is lower than low-threshold, a notification will be sent. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.5 | Columnh3cExtVoltageHighThreshold | read-write | current | The high-threshold for the voltage. When voltage is higher than high-threshold, a notification will be sent. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.6 | Columnh3cExtCriticalVoltageLowThreshold | read-write | current | The critical low threshold for voltage. If the voltage is lower too much than the entity needs, the entity will halt. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.7 | Columnh3cExtCriticalVoltageHighThreshold | read-write | current | The critical high threshold for voltage. If the voltage is higher too much than the entity needs, the entity will halt. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.8 | Columnh3cExtShutdownVoltageLowThreshold | read-write | current | The voltage is lower than the critical low threshold. If the voltage is lower too much than the entity needs, the entity halts now. |
| 1.3.6.1.4.1.2011.10.10.1.1.2.5.1.9 | Columnh3cExtShutdownVoltageHighThreshold | read-write | current | The voltage is higher than the critical high threshold. If the voltage is higher too much than the entity needs, the entity halts now. |
| 1.3.6.1.4.1.2011.10.10.1.1.3 | Nodeh3cStorageTraps | |||
| 1.3.6.1.4.1.2011.10.10.1.1.3.0 | Nodeh3cStorageTrapsPrefix | |||
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.1 | Notificationh3cStorCriticalLowerTemperatureThresholdNotification | current | The h3cStorCriticalLowerTemperatureThresholdNotification indicates the temperature is lower than the threshold. If the temperature is lower too much than the e… | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.2 | Notificationh3cStorTemperatureTooLow | current | The h3cStorTemperatureTooLow indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity halt… | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.3 | Notificationh3cExtVoltageLowThresholdNotification | current | The h3cExtVoltageLowThresholdNotification indicates the Voltage is lower than the low-threshold. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.4 | Notificationh3cExtVoltageHighThresholdNotification | current | The h3cExtVoltageHighThresholdNotification indicates the Voltage is lower than the high-threshold. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.5 | Notificationh3cExtCriticalVoltageLowThresholdNotification | current | The h3cExtCriticalVoltageLowThresholdNotification indicates the Voltage is lower than the critical low threshold. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.6 | Notificationh3cExtCriticalVoltageHighThresholdNotification | current | The h3cExtCriticalVoltageHighThresholdNotification indicates the Voltage is higher than the critical high threshold. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.7 | Notificationh3cExtVoltageTooLow | current | The h3cExtVoltageTooLowNotification indicates the Voltage is lower than the critical low threshold, and the entity halt now! | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.8 | Notificationh3cExtVoltageTooHigh | current | The h3cExtVoltageTooHighNotification indicates the Voltage is higher than the critical high threshold, and the entity halt now! | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.9 | Notificationh3cExtBatteryStateNotification | current | The h3cExtBatteryStateNotification indicates the raid battery entity's state changes. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.10 | Notificationh3cDiskIOErrorNotification | current | The h3cDiskIOErrorNotification indicates that a disk occurred I/O error. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.11 | Notificationh3cRaidCreateNotification | current | The h3cRaidCreateNotification indicates that a array is created. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.12 | Notificationh3cRaidDeleteNotification | current | The h3cRaidDeleteStateNotification indicates that a array is deleted. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.13 | Notificationh3cRaidHideStateNotification | current | The h3cRaidFailedNotification indicates that a array hide or unhide. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.14 | Notificationh3cRaidRunStateNotification | current | The h3cRaidDegradeNotification indicates that a array state change. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.15 | Notificationh3cRaidImportNotification | current | The h3cRaidFailedNotification indicates that a thrid array is imported. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.16 | Notificationh3cRaidRebuildStartNotification | current | The h3cRaidRebuildStartNotification indicates that a array start to rebuild. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.17 | Notificationh3cRaidRebuildFinishNotification | current | The h3cRaidRebuildStartNotification indicates that a array fininsh rebuild. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.18 | Notificationh3cRaidRebuildPauseNotification | current | The h3cRaidRebuildPauseNotification indicates that pause a array rebuilding. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.19 | Notificationh3cRaidRebuildInterruptNotification | current | The h3cRaidRebuildInterruptNotification indicates that interrupt a array rebuilding. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.20 | Notificationh3cSoftwareModuleFailNotification | current | The h3cSoftwareModuleFailNotification indicates that software module(s) fail. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.21 | Notificationh3cRaidBatteryExpiredNotification | current | The h3cRaidBatteryExpiredNotification indicates RAID Battery lifetime had expired. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.22 | Notificationh3cRaidBatteryWillExpireNotification | current | The h3cRaidBatteryWillExpireNotification indicates RAID Battery lifetime will expire. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.23 | Notificationh3cLvOnlineFailNotification | current | The h3cLvOnlineFailNotification indicates lv(s) on vd fail to online. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.24 | Notificationh3cLvOfflineFailNotification | current | The h3cLvOfflineFailNotification indicates lv(s) on vd fail to offline. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.25 | Notificationh3cRaidRunNotification | current | The h3cRaidRunNotification indicates that a array is running. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.26 | Notificationh3cExtVoltageNormal | current | The h3cStorVoltageRecoveryNotification indicates the Voltage has recovered in reference. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.27 | Notificationh3cDiskPowerOnNotification | current | The h3cDiskPowerOnNotification indicates that a disk is power on. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.0.28 | Notificationh3cDiskPowerOffNotification | current | The h3cDiskPowerOffNotification indicates that a disk is power off. | |
| 1.3.6.1.4.1.2011.10.10.1.1.3.1 | Nodeh3cStorageTrapsObjects | |||
| 1.3.6.1.4.1.2011.10.10.1.1.3.1.1 | Scalarh3cSoftwareInfoString | read-only | current | This object identifies if the software's information. |