MIB Viewer

H3C-TE-TUNNEL-MIB

49 objects
This MIB contains managed object definitions for the Multiprotocol Label Switching (MPLS) Te Tunnel.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.43.45.1.10.2.115Identityh3cTeTunnelThis MIB contains managed object definitions for the Multiprotocol Label Switching (MPLS) Te Tunnel.
1.3.6.1.4.1.43.45.1.10.2.115.1Nodeh3cTeTunnelScalars
1.3.6.1.4.1.43.45.1.10.2.115.1.1Scalarh3cTeTunnelMaxTunnelIndexread-onlycurrentThe max value of tunnel id is permitted configure on the device.
1.3.6.1.4.1.43.45.1.10.2.115.2Nodeh3cTeTunnelObjects
1.3.6.1.4.1.43.45.1.10.2.115.2.1Tableh3cTeTunnelStaticCrlspTablenot-accessiblecurrentThis table contains information for static-crlsp, and through this to get detail information about this static-crlsp. Only support transit LSR and egress LSR.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1Rowh3cTeTunnelStaticCrlspEntrynot-accessiblecurrentThe entry in this table describes static-crlsp information.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.1Columnh3cTeTunnelStaticCrlspInLabelnot-accessiblecurrentThis is unique label value that manualy assigned. Uniquely identifies a static-crlsp. Managers should use this to obtain detail static-crlsp information.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.2Columnh3cTeTunnelStaticCrlspNameread-onlycurrentThe unique name assigned to the static-crlsp.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.3Columnh3cTeTunnelStaticCrlspStatusread-onlycurrentIndicates the actual status of this static-crlsp, The value must be up when the static-crlsp status is up and the value must be down when the static-crlsp stat…
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.4Columnh3cTeTunnelStaticCrlspRoleread-onlycurrentThis value indicate the role of this static-crlsp. This value must be transit at transit point of the tunnel, and tail at terminating point of the tunnel.
1.3.6.1.4.1.43.45.1.10.2.115.2.1.1.5Columnh3cTeTunnelStaticCrlspXCPointerread-onlycurrentThis pointer unique identify a row of mplsXCTable. This value should be zeroDotZero when the static-crlsp is down. The mplsXCTable identifies the segments that…
1.3.6.1.4.1.43.45.1.10.2.115.2.2Tableh3cTeTunnelCoTablenot-accessiblecurrentThis table contains information for Co-routed reverse crlsp and infomation of Co-routed bidirectional Tunnel Interface. If h3cCorouteTunnelLspInstance is zero,…
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1Rowh3cTeTunnelCoEntrynot-accessiblecurrentThe entry in this table describes Co-routed infomation of bidirectional Tunnel Interface and reserver lsp information.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.1Columnh3cTeTunnelCoIndexnot-accessiblecurrentUniquely identifies a set of tunnel instances between a pair of ingress and egress LSRs that specified at originating point. This value should be equal to the …
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.2Columnh3cTeTunnelCoLspInstancenot-accessiblecurrentWhen obtain infomation of Co-routed bidirectional Tunnel Interface, this vlaue should be zero. And this value must be LspID to obtain reverse crlsp information…
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.3Columnh3cTeTunnelCoIngressLSRIdnot-accessiblecurrentIdentity the ingress LSR associated with this tunnel instance. This vlaue is equal to the LsrID of originating endpoint.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.4Columnh3cTeTunnelCoEgressLSRIdnot-accessiblecurrentIdentity of the egress LSR associated with this tunnel instance. This vlaue is equal to the LsrID of terminating point.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.5Columnh3cTeTunnelCoBiModeread-onlycurrentThis vlaue indicated the bidirection mode of tunnel interface. The valuemust be coroutedActive at the originating point of the tunnel and coroutedPassive at th…
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.6Columnh3cTeTunnelCoReverseLspInstanceread-onlycurrentThis value indicated the reverse lsp instance, and should be equal to obverse lsp instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.2.1.7Columnh3cTeTunnelCoReverseLspXCPointerread-onlycurrentThis pointer unique index to mplsXCTable of the reverse lsp. The mplsXCTable identifies the segments that compose this tunnel, their characteristics, and relat…
1.3.6.1.4.1.43.45.1.10.2.115.2.3Tableh3cTeTunnelPsTablenot-accessiblecurrentThis table defines some objects for managers to obtain TE tunnel Protection Switching group current status information.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1Rowh3cTeTunnelPsEntrynot-accessiblecurrentThe entry in this table describes TE tunnel Protection Switching group infromation.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.1Columnh3cTeTunnelPsIndexnot-accessiblecurrentUniquely identifies a TE tunnel Protection Switching group instance. This value must be equal to the tunnel id of work tunnel instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.2Columnh3cTeTunnelPsIngressLSRIdnot-accessiblecurrentIdentity the ingress LSR associated with work tunnel instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.3Columnh3cTeTunnelPsEgressLSRIdnot-accessiblecurrentIdentity of the egress LSR associated with work tunnel instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.4Columnh3cTeTunnelPsProtectIndexread-onlycurrentUniquely identifies a TE tunnel Protection Switching group instance. This value must be equal to the tunnel id of TE tunnel Protection Switching group instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.5Columnh3cTeTunnelPsProtectIngressLSRIdread-onlycurrentIdentity the ingress LSR associated with TE tunnel Protection Switching group instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.6Columnh3cTeTunnelPsProtectEgressLSRIdread-onlycurrentIdentity of the egress LSR associated with TE tunnel Protection Switching group instance.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.7Columnh3cTeTunnelPsProtectTyperead-onlycurrentThis value indicated TE tunnel Protection Switching group type. The default value is oneToOne.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.8Columnh3cTeTunnelPsRevertiveModeread-onlycurrentThis value indicated protect switch mode. The value must be revertive or nonRevertive, default value is revertive.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.9Columnh3cTeTunnelPsWtrTimeread-onlycurrentThe cycle time that switch to protect tunnel.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.10Columnh3cTeTunnelPsHoldOffTimeread-onlycurrentThis value is switchback delay time. When detected the work path fault, switch to protect path after this time.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.11Columnh3cTeTunnelPsSwitchModeread-onlycurrentThis value indicated TE tunnel Protection Switching group switch mode.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.12Columnh3cTeTunnelPsWorkPathStatusread-onlycurrentThis value indicates work path status. none, noDefect, inDefect will be used.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.13Columnh3cTeTunnelPsProtectPathStatusread-onlycurrentThis value indicates protect path status. none, noDefect, inDefect(3) will be used.
1.3.6.1.4.1.43.45.1.10.2.115.2.3.1.14Columnh3cTeTunnelPsSwitchResultread-onlycurrentThis value indicated current using path is work path or protect path.
1.3.6.1.4.1.43.45.1.10.2.115.3Nodeh3cTeTunnelNotifications
1.3.6.1.4.1.43.45.1.10.2.115.3.0Nodeh3cTeTunnelNotificationsPrefix
1.3.6.1.4.1.43.45.1.10.2.115.3.0.1Notificationh3cTeTunnelPsSwitchWtoPcurrentThis notification is generated when protect workgroup switch from work tunnel to protect tunnel.
1.3.6.1.4.1.43.45.1.10.2.115.3.0.2Notificationh3cTeTunnelPsSwitchPtoWcurrentThis notification is generated when protect workgroup switch from protect tunnel to work tunnel.
1.3.6.1.4.1.43.45.1.10.2.115.4Nodeh3cTeTunnelConformance
1.3.6.1.4.1.43.45.1.10.2.115.4.1Nodeh3cTeTunnelCompliances
1.3.6.1.4.1.43.45.1.10.2.115.4.1.1Complianceh3cTeTunnelCompliancecurrentThe compliance statement for SNMP.
1.3.6.1.4.1.43.45.1.10.2.115.4.2Nodeh3cTeTunnelGroups
1.3.6.1.4.1.43.45.1.10.2.115.4.2.1Grouph3cTeTunnelNotificationsGroupcurrentThis group contains MPLS Te Tunnel traps.
1.3.6.1.4.1.43.45.1.10.2.115.4.2.2Grouph3cTeTunnelScalarsGroupcurrentScalar object needed to implement MPLS te tunnels.
1.3.6.1.4.1.43.45.1.10.2.115.4.2.3Grouph3cTeTunnelStaticCrlspGroupcurrentObjects for quering static-crlsp information.
1.3.6.1.4.1.43.45.1.10.2.115.4.2.4Grouph3cTeTunnelCorouteGroupcurrentObjects for quering Co-routed reverse crlsp information.
1.3.6.1.4.1.43.45.1.10.2.115.4.2.5Grouph3cTeTunnelPsGroupcurrentObjects for quering protect workgroup information.