MIB Viewer

HH3C-STORAGE-MIB

91 objects
This MIB describes the general information of storage device, such as the property, configuration and management.
OIDNameAccessStatusDescription
1.3.6.1.4.1.25506.10.1Identityhh3cStorageMIBThis MIB describes the general information of storage device, such as the property, configuration and management.
1.3.6.1.4.1.25506.10.1.1Nodehh3cStorageMibObjects
1.3.6.1.4.1.25506.10.1.1.1Nodehh3cStorageServerInfo
1.3.6.1.4.1.25506.10.1.1.1.1Nodehh3cStorageServerCapability
1.3.6.1.4.1.25506.10.1.1.1.1.1Scalarhh3cRaidCapabilityread-onlycurrentThis object identifies if the agent support raid management.
1.3.6.1.4.1.25506.10.1.1.1.1.2Scalarhh3cFcCapabilityread-onlycurrentThis object identifies if the agent support FC(fiber channel) management.
1.3.6.1.4.1.25506.10.1.1.1.1.3Scalarhh3cNasCapabilityread-onlycurrentThis object identifies if the agent support NAS(Network Attached Storage).
1.3.6.1.4.1.25506.10.1.1.1.1.4Scalarhh3cAdaptiveRepCapabilityread-onlycurrentThis object identifies if the agent support adaptive replication. With adaptive replication option, data from the primary resource is continuously replicated t…
1.3.6.1.4.1.25506.10.1.1.1.1.5Scalarhh3cRemoteRepCapabilityread-onlycurrentThis object identifies if the agent support remote replication.
1.3.6.1.4.1.25506.10.1.1.1.1.6Scalarhh3cSafeCacheCapabilityread-onlycurrentThis object identifies if the agent support safe cache.
1.3.6.1.4.1.25506.10.1.1.1.1.7Scalarhh3cSyncMirrorCapabilityread-onlycurrentThis object identifies if the agent support synchronized mirror.
1.3.6.1.4.1.25506.10.1.1.1.1.8Scalarhh3cAsyncMirrorCapabilityread-onlycurrentThis object identifies if the agent support asynchronous mirror.
1.3.6.1.4.1.25506.10.1.1.1.1.9Scalarhh3cTimeMarkCapabilityread-onlycurrentThis object identifies if the agent support time mark.
1.3.6.1.4.1.25506.10.1.1.1.1.10Scalarhh3cSseCapabilityread-onlycurrentThis object identifies if the agent support SSE(Storage Service Enable).
1.3.6.1.4.1.25506.10.1.1.1.2Nodehh3cStorageTargetConfig
1.3.6.1.4.1.25506.10.1.1.1.2.1Scalarhh3ciSCSITargetEnableread-writecurrentThis object identifies if the agent support iSCSI target.
1.3.6.1.4.1.25506.10.1.1.1.2.2Scalarhh3cFcTargetEnableread-writecurrentThis object identifies if the agent support FC target.
1.3.6.1.4.1.25506.10.1.1.1.3Nodehh3cStorageServerPhysInfo
1.3.6.1.4.1.25506.10.1.1.1.3.1Scalarhh3cServerLocationLedStateread-writecurrentThis object identifies the state of storage device's location led.
1.3.6.1.4.1.25506.10.1.1.1.3.2Scalarhh3cServerResetButtonStateread-writecurrentThis object identifies if the reset button is enable.
1.3.6.1.4.1.25506.10.1.1.1.3.3Scalarhh3cServerPowerButtonStateread-writecurrentThis object identifies if the power button is enable.
1.3.6.1.4.1.25506.10.1.1.1.3.4Scalarhh3cServerPowerStateread-onlycurrentThis object identifies the state of power supply in the server, and is valid when UPS has been configured successful. The value 'online' means power supply is …
1.3.6.1.4.1.25506.10.1.1.2Nodehh3cStoragePhysicalInfo
1.3.6.1.4.1.25506.10.1.1.2.1Tablehh3cDeuTablenot-accessiblecurrentThis table contains some information of a particular DEU(Disk Enclosure Unit).
1.3.6.1.4.1.25506.10.1.1.2.1.1Rowhh3cDeuEntrynot-accessiblecurrentAn entry containing management information applicable to a particular DEU.
1.3.6.1.4.1.25506.10.1.1.2.1.1.1Columnhh3cDeuIndexnot-accessiblecurrentThis object identifies the index of hh3cDeuTable. The DEU identified by a particular value of this index is the same object as identified by the same value of …
1.3.6.1.4.1.25506.10.1.1.2.1.1.2Columnhh3cDeuIDLedread-writecurrentThis object identifies the state of storage DEU's led.
1.3.6.1.4.1.25506.10.1.1.2.1.1.3Columnhh3cDeuDiskScanread-writecurrentThe operation of scanning the table. When the value of this object is set to 'action', the operation of disk scanning is touched off.
1.3.6.1.4.1.25506.10.1.1.2.2Tablehh3cStorageInterfaceTablenot-accessiblecurrentThis table describes the interface information of the network.
1.3.6.1.4.1.25506.10.1.1.2.2.1Rowhh3cStorageInterfaceEntrynot-accessiblecurrentAn entry containing management information applicable to a particular interface.
1.3.6.1.4.1.25506.10.1.1.2.2.1.1Columnhh3cStorageInterfaceIndexnot-accessiblecurrentThis object identifies the index of Hh3cStorageInterfaceEntry. The interface identified by this index is the same interface as identified by the same value of …
1.3.6.1.4.1.25506.10.1.1.2.2.1.2Columnhh3cStorageInterfaceGatewayread-writecurrentThis object identifies the gateway address of interface.
1.3.6.1.4.1.25506.10.1.1.2.2.1.3Columnhh3cStorageInterfaceGatewayTyperead-writecurrentThis object identifies the gateway address type of interface.
1.3.6.1.4.1.25506.10.1.1.2.2.1.4Columnhh3cStorageInterfaceMTUread-writecurrentThis object identifies the MTU of interface.
1.3.6.1.4.1.25506.10.1.1.2.3Tablehh3cBondingTablenot-accessiblecurrentThis table describes the information of the Bonding interface.
1.3.6.1.4.1.25506.10.1.1.2.3.1Rowhh3cBondingEntrynot-accessiblecurrentAn entry containing management information applicable to a particular Bonding interface.
1.3.6.1.4.1.25506.10.1.1.2.3.1.1Columnhh3cBondingIndexnot-accessiblecurrentThis object identifies the index of hh3cBondingEntry. The interface identified by this index is the same interface as identified by the same value of ifIndex.
1.3.6.1.4.1.25506.10.1.1.2.3.1.2Columnhh3cBondingPortListread-writecurrentAn entry contains management information applicable to a particular bonding interface. Every two bytes describe the ifIndex of an interface, and an interface b…
1.3.6.1.4.1.25506.10.1.1.2.4Tablehh3cScsiAdapterTablenot-accessiblecurrentThis table containing some information of the SCSI(Small Computer System interface) adapter.
1.3.6.1.4.1.25506.10.1.1.2.4.1Rowhh3cScsiAdapterEntrynot-accessiblecurrentAn entry containing management information applicable to a particular SCSI adapter.
1.3.6.1.4.1.25506.10.1.1.2.4.1.1Columnhh3cAdapterNumbernot-accessiblecurrentThis object identifies the index of the adapter .
1.3.6.1.4.1.25506.10.1.1.2.4.1.2Columnhh3cAdapterDescread-onlycurrentThis object describes some information of the adapter.
1.3.6.1.4.1.25506.10.1.1.2.4.1.3Columnhh3cAdapterTyperead-onlycurrentThis object identifies the type of adapter. If the value of this object is not equal to 'fc', the associated object(such as hh3cFcAdapterMode, hh3cFcAdapterIWW…
1.3.6.1.4.1.25506.10.1.1.2.4.1.4Columnhh3cFcAdapterModeread-onlycurrentThis object identifies the mode type of adapter.
1.3.6.1.4.1.25506.10.1.1.2.4.1.5Columnhh3cFcAdapterInitiatorWwpnNameread-onlycurrentThis object describes the FC's adapter WWPN(World Wide Port Name) numbers.
1.3.6.1.4.1.25506.10.1.1.2.4.1.6Columnhh3cFcAdapterTargetWwpnNameread-onlycurrentThis object describes the FC's target WWPN numbers.
1.3.6.1.4.1.25506.10.1.1.2.4.1.7Columnhh3cFcAdapterPortStateread-onlycurrentThis object identifies the state of adapter's interface.
1.3.6.1.4.1.25506.10.1.1.2.4.1.8Columnhh3cFcAdapterModeSwitchread-writecurrentThis object identifies if the adapter work on a target mode.
1.3.6.1.4.1.25506.10.1.1.2.5Tablehh3cExtVoltageTablenot-accessiblecurrentThis table contains some entity extend information of the voltage.
1.3.6.1.4.1.25506.10.1.1.2.5.1Rowhh3cExtVoltageEntrynot-accessiblecurrentAn entry containing management information applicable to the voltage.
1.3.6.1.4.1.25506.10.1.1.2.5.1.1Columnhh3cExtVoltagePhysicalIndexaccessible-for-notifycurrentThis object identifies the entity index of voltage.
1.3.6.1.4.1.25506.10.1.1.2.5.1.2Columnhh3cExtVoltagePhysicalNameread-onlycurrentThis object identifies the entity name of voltage.
1.3.6.1.4.1.25506.10.1.1.2.5.1.3Columnhh3cExtVoltageread-onlycurrentThe voltage for the entity.
1.3.6.1.4.1.25506.10.1.1.2.5.1.4Columnhh3cExtVoltageLowThresholdread-writecurrentThe low-threshold for the voltage. When voltage is lower than low-threshold, a notification will be sent.
1.3.6.1.4.1.25506.10.1.1.2.5.1.5Columnhh3cExtVoltageHighThresholdread-writecurrentThe high-threshold for the voltage. When voltage is higher than high-threshold, a notification will be sent.
1.3.6.1.4.1.25506.10.1.1.2.5.1.6Columnhh3cExtCriticalVoltageLowThresholdread-writecurrentThe critical low threshold for voltage. If the voltage is lower too much than the entity needs, the entity will halt.
1.3.6.1.4.1.25506.10.1.1.2.5.1.7Columnhh3cExtCriticalVoltageHighThresholdread-writecurrentThe critical high threshold for voltage. If the voltage is higher too much than the entity needs, the entity will halt.
1.3.6.1.4.1.25506.10.1.1.2.5.1.8Columnhh3cExtShutdownVoltageLowThresholdread-writecurrentThe voltage is lower than the critical low threshold. If the voltage is lower too much than the entity needs, the entity halts now.
1.3.6.1.4.1.25506.10.1.1.2.5.1.9Columnhh3cExtShutdownVoltageHighThresholdread-writecurrentThe voltage is higher than the critical high threshold. If the voltage is higher too much than the entity needs, the entity halts now.
1.3.6.1.4.1.25506.10.1.1.3Nodehh3cStorageTraps
1.3.6.1.4.1.25506.10.1.1.3.0Nodehh3cStorageTrapsPrefix
1.3.6.1.4.1.25506.10.1.1.3.0.1Notificationhh3cStorCriticalLowerTemperatureThresholdNotificationcurrentThe hh3cStorCriticalLowerTemperatureThresholdNotification indicates the temperature is lower than the threshold. If the temperature is lower too much than the …
1.3.6.1.4.1.25506.10.1.1.3.0.2Notificationhh3cStorTemperatureTooLowcurrentThe hh3cStorTemperatureTooLow indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity hal…
1.3.6.1.4.1.25506.10.1.1.3.0.3Notificationhh3cExtVoltageLowThresholdNotificationcurrentThe hh3cExtVoltageLowThresholdNotification indicates the Voltage is lower than the low-threshold.
1.3.6.1.4.1.25506.10.1.1.3.0.4Notificationhh3cExtVoltageHighThresholdNotificationcurrentThe hh3cExtVoltageHighThresholdNotification indicates the Voltage is lower than the high-threshold.
1.3.6.1.4.1.25506.10.1.1.3.0.5Notificationhh3cExtCriticalVoltageLowThresholdNotificationcurrentThe hh3cExtCriticalVoltageLowThresholdNotification indicates the Voltage is lower than the critical low threshold.
1.3.6.1.4.1.25506.10.1.1.3.0.6Notificationhh3cExtCriticalVoltageHighThresholdNotificationcurrentThe hh3cExtCriticalVoltageHighThresholdNotification indicates the Voltage is higher than the critical high threshold.
1.3.6.1.4.1.25506.10.1.1.3.0.7Notificationhh3cExtVoltageTooLowcurrentThe hh3cExtVoltageTooLowNotification indicates the Voltage is lower than the critical low threshold, and the entity halt now!
1.3.6.1.4.1.25506.10.1.1.3.0.8Notificationhh3cExtVoltageTooHighcurrentThe hh3cExtVoltageTooHighNotification indicates the Voltage is higher than the critical high threshold, and the entity halt now!
1.3.6.1.4.1.25506.10.1.1.3.0.9Notificationhh3cExtBatteryStateNotificationcurrentThe hh3cExtBatteryStateNotification indicates the raid battery entity's state changes.
1.3.6.1.4.1.25506.10.1.1.3.0.10Notificationhh3cDiskIOErrorNotificationcurrentThe hh3cDiskIOErrorNotification indicates that a disk occurred I/O error.
1.3.6.1.4.1.25506.10.1.1.3.0.11Notificationhh3cRaidCreateNotificationcurrentThe hh3cRaidCreateNotification indicates that a array is created.
1.3.6.1.4.1.25506.10.1.1.3.0.12Notificationhh3cRaidDeleteNotificationcurrentThe hh3cRaidDeleteStateNotification indicates that a array is deleted.
1.3.6.1.4.1.25506.10.1.1.3.0.13Notificationhh3cRaidHideStateNotificationcurrentThe hh3cRaidFailedNotification indicates that a array hide or unhide.
1.3.6.1.4.1.25506.10.1.1.3.0.14Notificationhh3cRaidRunStateNotificationcurrentThe hh3cRaidDegradeNotification indicates that a array state change.
1.3.6.1.4.1.25506.10.1.1.3.0.15Notificationhh3cRaidImportNotificationcurrentThe hh3cRaidFailedNotification indicates that a thrid array is imported.
1.3.6.1.4.1.25506.10.1.1.3.0.16Notificationhh3cRaidRebuildStartNotificationcurrentThe hh3cRaidRebuildStartNotification indicates that a array start to rebuild.
1.3.6.1.4.1.25506.10.1.1.3.0.17Notificationhh3cRaidRebuildFinishNotificationcurrentThe hh3cRaidRebuildStartNotification indicates that a array fininsh rebuild.
1.3.6.1.4.1.25506.10.1.1.3.0.18Notificationhh3cRaidRebuildPauseNotificationcurrentThe hh3cRaidRebuildPauseNotification indicates that pause a array rebuilding.
1.3.6.1.4.1.25506.10.1.1.3.0.19Notificationhh3cRaidRebuildInterruptNotificationcurrentThe hh3cRaidRebuildInterruptNotification indicates that interrupt a array rebuilding.
1.3.6.1.4.1.25506.10.1.1.3.0.20Notificationhh3cSoftwareModuleFailNotificationcurrentThe hh3cSoftwareModuleFailNotification indicates that software module(s) fail.
1.3.6.1.4.1.25506.10.1.1.3.0.21Notificationhh3cRaidBatteryExpiredNotificationcurrentThe hh3cRaidBatteryExpiredNotification indicates RAID Battery lifetime had expired.
1.3.6.1.4.1.25506.10.1.1.3.0.22Notificationhh3cRaidBatteryWillExpireNotificationcurrentThe hh3cRaidBatteryWillExpireNotification indicates RAID Battery lifetime will expire.
1.3.6.1.4.1.25506.10.1.1.3.0.23Notificationhh3cLvOnlineFailNotificationcurrentThe hh3cLvOnlineFailNotification indicates lv(s) on vd fail to online.
1.3.6.1.4.1.25506.10.1.1.3.0.24Notificationhh3cLvOfflineFailNotificationcurrentThe hh3cLvOfflineFailNotification indicates lv(s) on vd fail to offline.
1.3.6.1.4.1.25506.10.1.1.3.0.25Notificationhh3cRaidRunNotificationcurrentThe hh3cRaidRunNotification indicates that a array is running.
1.3.6.1.4.1.25506.10.1.1.3.0.26Notificationhh3cExtVoltageNormalcurrentThe hh3cStorVoltageRecoveryNotification indicates the Voltage has recovered in reference.
1.3.6.1.4.1.25506.10.1.1.3.0.27Notificationhh3cDiskPowerOnNotificationcurrentThe hh3cDiskPowerOnNotification indicates that a disk is power on.
1.3.6.1.4.1.25506.10.1.1.3.0.28Notificationhh3cDiskPowerOffNotificationcurrentThe hh3cDiskPowerOffNotification indicates that a disk is power off.
1.3.6.1.4.1.25506.10.1.1.3.1Nodehh3cStorageTrapsObjects
1.3.6.1.4.1.25506.10.1.1.3.1.1Scalarhh3cSoftwareInfoStringread-onlycurrentThis object identifies if the software's information.