HM2-INDUSTRIAL-PROTOCOLS-MIB
113 objects
Hirschmann Industrial Protocols MIB. Copyright (C) 2013. All Rights Reserved.
Imported Objects
| HM2-TC-MIB | hm2ConfigurationMibs HmEnabledStatus |
| INET-ADDRESS-MIB | InetAddressIPv4 InetPortNumber |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString RowStatus TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.248.11.101 | Identityhm2IndustrialProtocolsMib | Hirschmann Industrial Protocols MIB. Copyright (C) 2013. All Rights Reserved. | ||
| 1.3.6.1.4.1.248.11.101.0 | Nodehm2IndustrialProtocolsNotifications | |||
| 1.3.6.1.4.1.248.11.101.1 | Nodehm2IndustrialProtocolsMibObjects | |||
| 1.3.6.1.4.1.248.11.101.1.1 | Nodehm2Iec61850Group | |||
| 1.3.6.1.4.1.248.11.101.1.1.1 | Nodehm2Iec61850ConfigGroup | |||
| 1.3.6.1.4.1.248.11.101.1.1.1.1 | Scalarhm2Iec61850MmsServerAdminStatus | read-write | current | Enables/disables the IEC61850 MMS server functionality on this device. If disabled(2), the IEC61850 MMS Server is deactivated, but the IEC61850 MIBs can be acc… |
| 1.3.6.1.4.1.248.11.101.1.1.1.2 | Scalarhm2Iec61850MmsServerWriteAccessStatus | read-write | current | Enables/disables the read/write capability of the IEC61850 MMS. If disabled(2), the IEC61850 MMS Server is accessible read-only, if enabled(1) the device confi… |
| 1.3.6.1.4.1.248.11.101.1.1.1.3 | Scalarhm2Iec61850MmsServerPortNumber | read-write | current | The port number of the IEC61850 MMS server. Setting the port to zero is not allowed. |
| 1.3.6.1.4.1.248.11.101.1.1.1.4 | Scalarhm2Iec61850MmsServerMaxSessionsCount | read-write | current | Max number of IEC61850 MMS sessions permitted on this switch. |
| 1.3.6.1.4.1.248.11.101.1.1.1.5 | Scalarhm2Iec61850MmsServerTechnicalKey | read-write | current | The IEC61850 MMS server technical key setting corresponds to the IEC61850 IED name. This name is used to identify the device via a IEC61850 MMS client. The siz… |
| 1.3.6.1.4.1.248.11.101.1.1.1.10 | Scalarhm2Iec61850MmsTlsServerAdminStatus | read-write | current | Enables/disables the IEC61850 MMS over TLS server functionality on this device. If disabled(2), the IEC61850 MMS over TLS Server is deactivated, but the IEC618… |
| 1.3.6.1.4.1.248.11.101.1.1.1.11 | Scalarhm2Iec61850MmsTlsServerWriteAccessStatus | read-write | current | Enables/disables the read/write capability of the IEC61850 MMS. If disabled(2), the IEC61850 MMS over TLS Server is accessible read-only, if enabled(1) the dev… |
| 1.3.6.1.4.1.248.11.101.1.1.1.12 | Scalarhm2Iec61850MmsTlsServerPortNumber | read-write | current | The port number of the IEC61850 MMS over TLS server. Setting the port to zero is not allowed. |
| 1.3.6.1.4.1.248.11.101.1.1.1.13 | Scalarhm2Iec61850MmsTlsServerMaxSessionsCount | read-write | current | Max number of IEC61850 MMS over TLS sessions permitted on this switch. |
| 1.3.6.1.4.1.248.11.101.1.1.1.20 | Scalarhm2Iec61850MmsTlsServerKeysPresent | read-only | current | Indicates what key files are present on the device, if any. |
| 1.3.6.1.4.1.248.11.101.1.1.1.21 | Scalarhm2Iec61850MmsTlsServerKeyOperStatus | read-only | current | Indicates what key files are currently being generated or deleted, if any. |
| 1.3.6.1.4.1.248.11.101.1.1.1.22 | Scalarhm2Iec61850MmsTlsServerRSAKeyControl | read-write | current | Controls RSA key generation and deletion. Always returns noop(1). |
| 1.3.6.1.4.1.248.11.101.1.1.1.23 | Scalarhm2Iec61850MmsTlsServerDSAKeyControl | read-write | current | Controls DSA key generation and deletion. Always returns noop(1). |
| 1.3.6.1.4.1.248.11.101.1.1.1.24 | Scalarhm2Iec61850MmsTlsServerFingerPrintDSA | read-only | current | The local DSA fingerprint for IEC61850 MMS over TLS connections. |
| 1.3.6.1.4.1.248.11.101.1.1.1.25 | Scalarhm2Iec61850MmsTlsServerFingerPrintRSA | read-only | current | The local RSA fingerprint for IEC61850 MMS over TLS connections. |
| 1.3.6.1.4.1.248.11.101.1.1.1.26 | Scalarhm2Iec61850MmsServerStatus | read-only | current | Returns current MMS server status. As the MMS server takes a long time to start or to stop, this will return the actual server state, not just if it is enabled… |
| 1.3.6.1.4.1.248.11.101.1.1.2 | Nodehm2Iec61850StatisticsGroup | |||
| 1.3.6.1.4.1.248.11.101.1.1.2.1 | Scalarhm2Iec61850MmsServerSessionsCount | read-only | current | Current number of active IEC61850 MMS sessions on this switch. |
| 1.3.6.1.4.1.248.11.101.1.1.2.10 | Scalarhm2Iec61850MmsTlsServerSessionsCount | read-only | current | Current number of active IEC61850 MMS over TLS sessions on this switch. |
| 1.3.6.1.4.1.248.11.101.1.2 | Nodehm2ProfinetIOGroup | |||
| 1.3.6.1.4.1.248.11.101.1.2.1 | Nodehm2ProfinetIOConfigGroup | |||
| 1.3.6.1.4.1.248.11.101.1.2.1.1 | Scalarhm2PNIOAdminStatus | read-write | current | Enables/disables the ProfinetIO functionality on this device. If disabled(2), the ProfinetIO protocol is inactive, but the ProfinetIO MIBs can be accessed. The… |
| 1.3.6.1.4.1.248.11.101.1.2.1.2 | Scalarhm2PNIODeviceID | read-only | current | Identifier of the device family. Values 1 .. 65635 are valid device IDs. |
| 1.3.6.1.4.1.248.11.101.1.2.1.3 | Scalarhm2PNIOModuleIdentNumber | read-only | current | Identifier ID of the device of port or module. |
| 1.3.6.1.4.1.248.11.101.1.2.1.4 | Scalarhm2PNIOOrderID | read-only | current | Product (switch) order ID. The size is restricted to 64 characters. |
| 1.3.6.1.4.1.248.11.101.1.2.1.5 | Scalarhm2PNIODeviceTypeDetails | read-only | current | Switch device type details, for example: 4 Port Rail Switch. |
| 1.3.6.1.4.1.248.11.101.1.2.1.6 | Scalarhm2PNIOSoftwareRelease | read-only | current | This value is a string that contains Version number of software in profinetio format, for example: 01.0.03. |
| 1.3.6.1.4.1.248.11.101.1.2.1.7 | Scalarhm2PNIOHardwareRelease | read-only | current | Version number of switch hardware in profinetio format. |
| 1.3.6.1.4.1.248.11.101.1.2.1.8 | Scalarhm2PNIOOrderID9th | read-only | current | Product (switch) order ID. The size is restricted to 32 characters (In the form of the 9-th numbers). |
| 1.3.6.1.4.1.248.11.101.1.2.1.9 | Scalarhm2PNIONameOfStation | read-write | current | Device name. The size is restricted to 240 characters. It must be conform to the restrictions as decribed in PNIO protocol specification. |
| 1.3.6.1.4.1.248.11.101.1.2.1.10 | Scalarhm2PNIONumActiveApplicationRelations | read-only | current | Returns the number of active application relations. |
| 1.3.6.1.4.1.248.11.101.1.2.1.11 | Scalarhm2PNIOClearIpParameter | read-write | current | Clears the IP parameters if set to true and PNIO is enabled. |
| 1.3.6.1.4.1.248.11.101.1.2.1.20 | Tablehm2PNIODcpModeTable | not-accessible | current | Table of DCP mode entries |
| 1.3.6.1.4.1.248.11.101.1.2.1.20.1 | Rowhm2PNIODcpModeEntry | not-accessible | current | DCP mode entry |
| 1.3.6.1.4.1.248.11.101.1.2.1.20.1.1 | Columnhm2PNIODcpModePortID | not-accessible | current | Port ID for the DCP mode table entry |
| 1.3.6.1.4.1.248.11.101.1.2.1.20.1.2 | Columnhm2PNIODcpMode | read-write | current | DCP mode for one port. Allowed values none(0), ingress(1), egress(2) or both(3) which is default. |
| 1.3.6.1.4.1.248.11.101.1.2.1.21 | Scalarhm2PNIOIm1Data | read-write | current | I&M1 data contains 2 fields: Tag function is a 32 byte visible string that indicates the submodule's function or task. Tag location is a 22 byte visible string… |
| 1.3.6.1.4.1.248.11.101.1.2.1.22 | Scalarhm2PNIOIm2Data | read-write | current | I&M2 is a Date and time function in the YYYY-MM-DD HH:MM format. For example, 2018-08-10 10:50 |
| 1.3.6.1.4.1.248.11.101.1.2.1.23 | Scalarhm2PNIOIm3Data | read-write | current | I&M3 is a general Descriptor function that is a 54 byte visible string for holding additional information. |
| 1.3.6.1.4.1.248.11.101.1.2.1.24 | Scalarhm2PNIOIm4Data | read-write | current | I&M4 is used for a signature with PROFIsafe. |
| 1.3.6.1.4.1.248.11.101.1.2.1.25 | Scalarhm2PNIOClearStationName | read-write | current | Clear Station Name if set to true and PNIO is enabled. |
| 1.3.6.1.4.1.248.11.101.1.2.1.26 | Scalarhm2PNIOPdevParameters | read-write | current | PDEV parameters of ApplicationRelation |
| 1.3.6.1.4.1.248.11.101.1.2.2 | Nodehm2ProfinetIOStatisticsGroup | |||
| 1.3.6.1.4.1.248.11.101.1.3 | Nodehm2EthernetIPGroup | |||
| 1.3.6.1.4.1.248.11.101.1.3.1 | Nodehm2EthernetIPConfigGroup | |||
| 1.3.6.1.4.1.248.11.101.1.3.1.1 | Scalarhm2EtherNetIPAdminStatus | read-write | current | Enables/disables the EtherNet/IP(TM) operation on this device. If disabled, the EtherNet/IP protocol is deactivated, but the EtherNet/IP MIBs can be accessed. … |
| 1.3.6.1.4.1.248.11.101.1.3.1.2 | Scalarhm2EtherNetIPErrorCode | read-only | current | Read the error code within EtherNet/IP(TM) action. |
| 1.3.6.1.4.1.248.11.101.1.3.1.3 | Scalarhm2EtherNetIPProductCode | read-only | current | Read the Product Code as shown in the Identity Object of EtherNet/IP(TM). Values 1 .. 65635 are valid product codes. |
| 1.3.6.1.4.1.248.11.101.1.3.1.4 | Scalarhm2EtherNetIPMajorRevision | read-only | current | Read the major revision number as shown in the Identity Object of EtherNet/IP(TM). Values 1 .. 255 are valid revisions. |
| 1.3.6.1.4.1.248.11.101.1.3.1.5 | Scalarhm2EtherNetIPMinorRevision | read-only | current | Read the minor revision number as shown in the Identity Object of EtherNet/IP(TM). Values 1 .. 255 are valid revisions. |
| 1.3.6.1.4.1.248.11.101.1.3.1.6 | Scalarhm2EtherNetIPProductName | read-only | current | Read the product name as shown in the Identity Object of EtherNet/IP(TM). The size is restricted to 32 Characters. |
| 1.3.6.1.4.1.248.11.101.1.3.1.7 | Scalarhm2EtherNetIPCatalogName | read-only | current | Read the catolog name as provided in the EDS file for EtherNet/IP(TM). The size is restricted to 255 Characters. |
| 1.3.6.1.4.1.248.11.101.1.3.1.8 | Scalarhm2EtherNetIPWriteAccessStatus | read-write | current | Enables/disables the read/write capability of the EtherNet/IP protocol. If disabled(2), the EtherNet/IP protocol is accessible the get requests only, if enable… |
| 1.3.6.1.4.1.248.11.101.1.3.1.9 | Scalarhm2EtherNetIPVlan | read-write | current | Set the VLAN ID of EtherNet/IP. Possible values for the VLAN ID are -1 to 4042. A value of -1 corresponds to management VLAN(the default). A value 0 is for pri… |
| 1.3.6.1.4.1.248.11.101.1.3.1.10 | Scalarhm2EtherNetIPInterface | read-write | current | Sets the mode of the various interface for EtherNet/IP for this device. EtherNet/IP traffic configure with physical interface EtherNet/IP traffic configure wit… |
| 1.3.6.1.4.1.248.11.101.1.3.2 | Nodehm2EthernetIPStatisticsGroup | |||
| 1.3.6.1.4.1.248.11.101.1.3.2.1 | Scalarhm2EtherNetIPConnEstablished | read-only | current | Statistics: number of connections that have been established within EtherNet/IP. |
| 1.3.6.1.4.1.248.11.101.1.3.2.2 | Scalarhm2EtherNetIPConnTimeouts | read-only | current | Statistics: number of connection timeouts that have been occurred within EtherNet/IP. |
| 1.3.6.1.4.1.248.11.101.1.3.2.3 | Scalarhm2EtherNetIPVendorObjRequests | read-only | current | Statistics: number of requests to the vendor specific objects within EtherNet/IP. |
| 1.3.6.1.4.1.248.11.101.1.3.3 | Nodehm2EthernetIPTCPIPObjectGroup | |||
| 1.3.6.1.4.1.248.11.101.1.3.3.1 | Scalarhm2EtherNetIPMcastTTLValue | read-write | current | Time-to-Live value for IP multicast packets. |
| 1.3.6.1.4.1.248.11.101.1.3.3.2 | Scalarhm2EtherNetIPMcastAllocControl | read-write | current | Controls how the device shall allocate IP multicast addresses. A value of 0 means multicast addresses shall be generated using the default allocation algorithm… |
| 1.3.6.1.4.1.248.11.101.1.3.3.3 | Scalarhm2EtherNetIPMcastCount | read-write | current | The maximum number of IP multicast addresses to be allocated. |
| 1.3.6.1.4.1.248.11.101.1.3.3.4 | Scalarhm2EtherNetIPMcastStartAddress | read-write | current | The starting multicast address from which Num Mcast addresses are allocated. |
| 1.3.6.1.4.1.248.11.101.1.3.3.5 | Scalarhm2EtherNetIPLastConflictDetectedACDActivity | read-write | current | The ARP Response PDU (a copy of the ARP message that caused the address conflict) in binary format. Can only be written to a value of zero. |
| 1.3.6.1.4.1.248.11.101.1.3.3.6 | Scalarhm2EtherNetIPSelectACDStatus | read-write | current | Sets the status of the ip address conflict detection mechanism on this device. The new value of this element is applied after the device executes a restart. |
| 1.3.6.1.4.1.248.11.101.1.3.3.7 | Scalarhm2EtherNetIPEncapsulationInactivity | read-write | current | sets the EncapsulationInactivity timeout. After a period of no Encapsulation activity on a TCP connection originator and target shall close the TCP connection. |
| 1.3.6.1.4.1.248.11.101.1.3.4 | Nodehm2EthernetIPQoSObjectGroup | |||
| 1.3.6.1.4.1.248.11.101.1.3.4.1 | Scalarhm2EtherNetIPQosDscpUrgentValue | read-write | current | DSCP value for CIP transport Urgent priority messages. |
| 1.3.6.1.4.1.248.11.101.1.3.4.2 | Scalarhm2EtherNetIPQosDscpScheduledValue | read-write | current | DSCP value for CIP transport Scheduled priority messages. |
| 1.3.6.1.4.1.248.11.101.1.3.4.3 | Scalarhm2EtherNetIPQosDscpHighValue | read-write | current | DSCP value for CIP transport High priority messages. |
| 1.3.6.1.4.1.248.11.101.1.3.4.4 | Scalarhm2EtherNetIPQosDscpLowValue | read-write | current | DSCP value for CIP transport Low priority messages. |
| 1.3.6.1.4.1.248.11.101.1.3.4.5 | Scalarhm2EtherNetIPQosDscpExplicitValue | read-write | current | DSCP value for CIP transport Explicit priority messages. |
| 1.3.6.1.4.1.248.11.101.1.3.4.6 | Scalarhm2EtherNetIPQosValue | read-write | current | This object indicates a changes which be applied after the device executes a restart. |
| 1.3.6.1.4.1.248.11.101.1.4 | Nodehm2ModbusGroup | |||
| 1.3.6.1.4.1.248.11.101.1.4.1 | Nodehm2ModbusConfigGroup | |||
| 1.3.6.1.4.1.248.11.101.1.4.1.1 | Scalarhm2ModbusTcpServerAdminStatus | read-write | current | Enables/disables the Modbus TCP server functionality on this device. If disabled(2), the Modbus TCP Server is deactivated, but the Modbus MIBs can be accessed.… |
| 1.3.6.1.4.1.248.11.101.1.4.1.2 | Scalarhm2ModbusTcpServerWriteAccessStatus | read-write | current | Enables/disables the read/write capability of the Modbus TCP server. If disabled(2), the Modbus TCP Server is accessible read-only, if enabled(1) the device co… |
| 1.3.6.1.4.1.248.11.101.1.4.1.3 | Scalarhm2ModbusTcpServerPortNumber | read-write | current | The port number of the Modbus TCP server. Setting the port to zero is not allowed. |
| 1.3.6.1.4.1.248.11.101.1.4.1.4 | Scalarhm2ModbusTcpServerMaxSessionsCount | read-write | current | Maximum number of concurrent sessions allowed by the Modbus TCP server. |
| 1.3.6.1.4.1.248.11.101.1.4.2 | Nodehm2ModbusStatisticsGroup | |||
| 1.3.6.1.4.1.248.11.101.1.4.2.1 | Scalarhm2ModbusTcpServerSessionsCount | read-only | current | Current number of active sessions to the Modbus TCP server. |
| 1.3.6.1.4.1.248.11.101.1.5 | Nodehm2Iec62541Group | |||
| 1.3.6.1.4.1.248.11.101.1.5.1 | Nodehm2Iec62541ConfigGroup | |||
| 1.3.6.1.4.1.248.11.101.1.5.1.1 | Scalarhm2Iec62541OpcUaServerAdminStatus | read-write | current | Enables/disables the Iec62541 OPC/UA server functionality on this device. If disabled(2), the Iec62541 OPC/UA Server is deactivated, but the Iec62541 OPC/UA MI… |
| 1.3.6.1.4.1.248.11.101.1.5.1.2 | Scalarhm2Iec62541OpcUaServerPortNumber | read-write | current | The port number of the Iec62541 OPC/UA server. Setting the port to zero is not allowed. |
| 1.3.6.1.4.1.248.11.101.1.5.1.3 | Scalarhm2Iec62541OpcUaMaxSessionsCount | read-write | current | Maximum number of OpcUa sessions. An integer value from 1 to 5 specifies the maximum number of OpcUa sessions that can be established. The full range is not su… |
| 1.3.6.1.4.1.248.11.101.1.5.1.4 | Scalarhm2Iec62541OpcUaSecurityPolicy | read-write | current | The security policy of the Iec62541 OPC/UA server. |
| 1.3.6.1.4.1.248.11.101.1.5.1.10 | Tablehm2Iec62541OpcUaUserConfigTable | not-accessible | current | OpcUa User configuration table. This table provides the functionality the OpcUa Server uses for any interaction started by the user - authentication, password … |
| 1.3.6.1.4.1.248.11.101.1.5.1.10.1 | Rowhm2Iec62541OpcUaUserConfigEntry | not-accessible | current | OpcUa User configuration entry. |
| 1.3.6.1.4.1.248.11.101.1.5.1.10.1.1 | Columnhm2Iec62541OpcUaUserName | accessible-for-notify | current | OpcUa user name. |
| 1.3.6.1.4.1.248.11.101.1.5.1.10.1.2 | Columnhm2Iec62541OpcUaUserPassword | read-create | current | OpcUa user password This object will always return '********' when read. |
| 1.3.6.1.4.1.248.11.101.1.5.1.10.1.3 | Columnhm2Iec62541OpcUaUserAccessRole | read-create | current | OpcUa user's access role. The user's access role can be set while the row is active. |
| 1.3.6.1.4.1.248.11.101.1.5.1.10.1.5 | Columnhm2Iec62541OpcUaUserStatus | read-create | current | OpcUa user status. active(1) - This user account is active. notInService(2) - Row has been suspended. notReady(3) - Row has incomplete values. createAndGo(4) -… |
| 1.3.6.1.4.1.248.11.101.3 | Nodehm2IndustrialProtocolsMibSNMPExtensionGroup | |||
| 1.3.6.1.4.1.248.11.101.3.1 | Nodehm2Iec61850SESGroup | |||
| 1.3.6.1.4.1.248.11.101.3.2 | Nodehm2ProfinetIOSESGroup | |||
| 1.3.6.1.4.1.248.11.101.3.2.1 | Identityhm2ProfinetIOInvalidStationName | current | Invalid station name. | |
| 1.3.6.1.4.1.248.11.101.3.2.2 | Identityhm2ProfinetIOARActive | current | Set not allowed, a Profinet application relation is active. | |
| 1.3.6.1.4.1.248.11.101.3.3 | Nodehm2EthernetIPSESGroup | |||
| 1.3.6.1.4.1.248.11.101.3.3.1 | Identityhm2EthernetIPUsedVlanId | current | VLAN not available, it is already used by another protocol. | |
| 1.3.6.1.4.1.248.11.101.3.3.2 | Identityhm2EthernetIPNoVlanId | current | VLAN does not exist. | |
| 1.3.6.1.4.1.248.11.101.3.3.3 | Identityhm2EthernetIPDynamicVlan | current | Dynamic VLANs are not allowed. Use a static VLAN. | |
| 1.3.6.1.4.1.248.11.101.3.3.4 | Identityhm2EthernetIPVlanUnaware | current | EtherNet/IP Separate VLAN cannot be used together with the VLAN Unaware Mode. | |
| 1.3.6.1.4.1.248.11.101.3.4 | Nodehm2ModbusSESGroup | |||
| 1.3.6.1.4.1.248.11.101.3.5 | Nodehm2Iec62541SESGroup |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Hm2Iec62541OpcUaSecurityPolicies | INTEGER { none (1), basic128Rsa15 (2), basic256 (3), basic256Sha256 (4) } | current | OPC/UA server security policy. |
| Hm2Iec62541OpcUaUserAccessRoles | INTEGER { readOnly (1) } | current | user access roles. |