HM2-IOMODULE-MIB
40 objects
Hirschmann IO Module MIB. Copyright (C) 2012. All Rights Reserved.
Imported Objects
| HM2-TC-MIB | hm2ConfigurationMibs HmEnabledStatus |
| INET-ADDRESS-MIB | InetAddress InetAddressType InetPortNumber |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.248.11.100 | Identityhm2IOModuleMib | Hirschmann IO Module MIB. Copyright (C) 2012. All Rights Reserved. | ||
| 1.3.6.1.4.1.248.11.100.0 | Nodehm2IOModuleMibNotifications | |||
| 1.3.6.1.4.1.248.11.100.0.1 | Notificationhm2IOModDigInputChangeTrap | current | This trap is sent if the state of an input changes. This trap is sent only when hm2IOModConfigDigInputSnmpTrap is set to enabled (1). | |
| 1.3.6.1.4.1.248.11.100.0.2 | Notificationhm2IOModDigOutputChangeTrap | current | This trap is sent if the state of an input changes. This trap is sent when hm2IOModConfigDigOutputSnmpTrap is set to enabled (1) or when the output value chang… | |
| 1.3.6.1.4.1.248.11.100.1 | Nodehm2IOModuleMibObjects | |||
| 1.3.6.1.4.1.248.11.100.1.1 | Nodehm2IOModConfigGroup | |||
| 1.3.6.1.4.1.248.11.100.1.1.1 | Nodehm2IOModConfigCommon | |||
| 1.3.6.1.4.1.248.11.100.1.1.1.1 | Scalarhm2IOModConfigDigInputAdminState | read-write | current | Enables polling of input values. (if disable(2) input task will do nothing) |
| 1.3.6.1.4.1.248.11.100.1.1.1.2 | Scalarhm2IOModConfigDigOutputAdminState | read-write | current | Enables mirroring of input values to output ports. (if disable(2) output task will do nothing) |
| 1.3.6.1.4.1.248.11.100.1.1.1.3 | Scalarhm2IOModConfigDigInputRefreshInterval | read-write | current | The refresh interval (in ms) of the input values. The accuracy of the interval value is 100ms. Minimum 1000ms (1s), Maximum 10000ms (10s). |
| 1.3.6.1.4.1.248.11.100.1.1.1.4 | Scalarhm2IOModConfigDigOutputRefreshInterval | read-write | current | The refresh interval (in ms) of the output values. The accuracy of the interval value is 100ms. Minimum 1000ms (1s), Maximum 10000ms (10s). |
| 1.3.6.1.4.1.248.11.100.1.1.1.5 | Scalarhm2IOModConfigDigOutputRetryCount | read-write | current | The retry count for the output values. when after the number of configured retries no SNMP get request was answered, the output value (hm2IOModValueDigOutputVa… |
| 1.3.6.1.4.1.248.11.100.1.1.2 | Tablehm2IOModConfigDigInputTable | not-accessible | current | IO module config table for inputs |
| 1.3.6.1.4.1.248.11.100.1.1.2.1 | Rowhm2IOModConfigDigInputEntry | not-accessible | current | IO module config entry for inputs |
| 1.3.6.1.4.1.248.11.100.1.1.2.1.1 | Columnhm2IOModConfigDigInputModID | not-accessible | current | The module ID of an input. Module ID 0 corresponds to the power supply module. |
| 1.3.6.1.4.1.248.11.100.1.1.2.1.2 | Columnhm2IOModConfigDigInputID | not-accessible | current | The ID of an input. |
| 1.3.6.1.4.1.248.11.100.1.1.2.1.3 | Columnhm2IOModConfigDigInputLogEvent | read-write | current | Trigger an event log when input status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entry… |
| 1.3.6.1.4.1.248.11.100.1.1.2.1.4 | Columnhm2IOModConfigDigInputSnmpTrap | read-write | current | Trigger an SNMP trap log when input status changes. If the value is disable (2), no SNMP trap will be sent. If the value is enable (1), a SNMP trap will be sen… |
| 1.3.6.1.4.1.248.11.100.1.1.3 | Tablehm2IOModConfigDigOutputTable | not-accessible | current | IO module config table for outputs. |
| 1.3.6.1.4.1.248.11.100.1.1.3.1 | Rowhm2IOModConfigDigOutputEntry | not-accessible | current | IO module config entry for outputs |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.1 | Columnhm2IOModConfigDigOutputModID | not-accessible | current | The module ID of an output. Module ID 0 corresponds to the power supply module. |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.2 | Columnhm2IOModConfigDigOutputID | not-accessible | current | The ID of an output. |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.3 | Columnhm2IOModConfigDigOutputLogEvent | read-write | current | Trigger an event log when output status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entr… |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.4 | Columnhm2IOModConfigDigOutputSnmpTrap | read-write | current | Trigger an SNMP trap log when output status changes. If the value is disable (2), no SNMP trap will be sent. If the value is enable (1), a SNMP trap will be se… |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.5 | Columnhm2IOModConfigDigOutputSourceAddressType | read-write | current | Address type of an input mirrored to the output. Currently, only ipv4 is supported. |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.6 | Columnhm2IOModConfigDigOutputSourceAddress | read-write | current | The IP address of an input mirrored to the output. Use 0.0.0.0 if the output should not be set. In this case hm2IOModValueDigOutputValue is not-configured(4). … |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.7 | Columnhm2IOModConfigDigOutputSourcePort | read-write | current | The SNMP port number being used by the input mirrored to the output. This port would be the destination of the SNMP requests for polling the state of the input. |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.8 | Columnhm2IOModConfigDigOutputSourceModID | read-write | current | The module ID of an input mirrored to the output. Module ID 0 corresponds to the power supply module. Ignored when hm2IOModConfigDigOutputSourceIP is 0.0.0.0. |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.9 | Columnhm2IOModConfigDigOutputSourceID | read-write | current | The ID of an input mirrored to the output. Ignored when hm2IOModConfigDigOutputSourceIP is 0.0.0.0. |
| 1.3.6.1.4.1.248.11.100.1.2 | Nodehm2IOModValueGroup | |||
| 1.3.6.1.4.1.248.11.100.1.2.1 | Tablehm2IOModValueDigInputTable | not-accessible | current | IO module value table for inputs |
| 1.3.6.1.4.1.248.11.100.1.2.1.1 | Rowhm2IOModValueDigInputEntry | not-accessible | current | IO module value entry for inputs |
| 1.3.6.1.4.1.248.11.100.1.2.1.1.1 | Columnhm2IOModValueDigInputModID | not-accessible | current | The module ID of an input. Module ID 0 corresponds to the power supply module. |
| 1.3.6.1.4.1.248.11.100.1.2.1.1.2 | Columnhm2IOModValueDigInputID | not-accessible | current | The ID of an input. |
| 1.3.6.1.4.1.248.11.100.1.2.1.1.3 | Columnhm2IOModValueDigInputValue | read-only | current | Status of the input. If the value is not-available(0), then the IO module is not plugged in, if the value is high(1), the input has high (+24V) value, if the v… |
| 1.3.6.1.4.1.248.11.100.1.2.2 | Tablehm2IOModValueDigOutputTable | not-accessible | current | IO module value table for outputs |
| 1.3.6.1.4.1.248.11.100.1.2.2.1 | Rowhm2IOModValueDigOutputEntry | not-accessible | current | IO module value entry for outputs |
| 1.3.6.1.4.1.248.11.100.1.2.2.1.1 | Columnhm2IOModValueDigOutputModID | not-accessible | current | The module ID of an Output. Module ID 0 corresponds to the power supply module. |
| 1.3.6.1.4.1.248.11.100.1.2.2.1.2 | Columnhm2IOModValueDigOutputID | not-accessible | current | The ID of an Output. |
| 1.3.6.1.4.1.248.11.100.1.2.2.1.3 | Columnhm2IOModValueDigOutputValue | read-only | current | Status of the output. If the value is not-available(0), then the IO module is not plugged in, if the value is high(1), the output has high (+24V) value, if the… |