MIB Viewer

HP-ICF-INST-MON

23 objects
This MIB module contains HP proprietary definitions for Instrumentation Monitor.
Imported Objects
HP-ICF-OIDhpSwitch
IF-MIBInterfaceIndexOrZero
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.11.2.14.11.5.1.35IdentityhpicfInstMonMIBThis MIB module contains HP proprietary definitions for Instrumentation Monitor.
1.3.6.1.4.1.11.2.14.11.5.1.35.1NodehpicfInstMonObjects
1.3.6.1.4.1.11.2.14.11.5.1.35.1.1ScalarhpicfInstMonLogEnableread-writecurrentThe operational status of the Instrumentation Monitor on this switch.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.2ScalarhpicfInstMonTrapEnableread-writecurrentThe operational status of the Monitor notifications on this switch.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.3TablehpicfInstMonParameterTablenot-accessiblecurrentConfiguration of monitored instrumentation parameters.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.3.1RowhpicfInstMonParameterEntrynot-accessiblecurrentAn entry in the hpicfInstMonParameterTable.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.3.1.1ColumnhpicfInstMonInterfaceIndexnot-accessiblecurrent0 for global parameters, port number for per-port parameters.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.3.1.2ColumnhpicfInstMonParameterIndexnot-accessiblecurrentThe index of the parameter.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.3.1.3ColumnhpicfInstMonParameterNameread-onlycurrentThe name of the parameter.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.3.1.4ColumnhpicfInstMonParameterThresholdread-writecurrentGenerate notification if the limit is not 0 and parameter value is beyond this limit.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.4ScalarhpicfInstMonNotificationTextread-onlycurrentThis string is sent with hpicfInstMonNotification.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.5NotificationhpicfInstMonNotificationcurrentThis notification is generated when the monitored parameter is beyond the configured threshold value.
1.3.6.1.4.1.11.2.14.11.5.1.35.1.6ScalarhpicfInstConfigread-writecurrentThis object enables/disables instrumentation on the switch. The value true(1) means that instrumentation is enabled; the value false(2) means that instrumentat…
1.3.6.1.4.1.11.2.14.11.5.1.35.2NodehpicfInstMonConformance
1.3.6.1.4.1.11.2.14.11.5.1.35.2.1NodehpicfInstMonGroups
1.3.6.1.4.1.11.2.14.11.5.1.35.2.1.1GrouphpicfInstMonNotificationGroupcurrentThis notification is generated by Monitor when parameter is beyond its threshold limit.
1.3.6.1.4.1.11.2.14.11.5.1.35.2.1.2GrouphpicfInstMonBaseGroupcurrentA collection of objects to support basic Instrumentation Monitor configuration on HP switches.
1.3.6.1.4.1.11.2.14.11.5.1.35.2.1.3GrouphpicfInstConfigGroupcurrentA collection of objects to support basic Instrumentation Collection configuration on HP switches.
1.3.6.1.4.1.11.2.14.11.5.1.35.2.1.4GrouphpicfInstMonNotifyGroupcurrentA collection of objects to support basic notification details on HP switches.
1.3.6.1.4.1.11.2.14.11.5.1.35.2.2NodehpicfInstMonCompliances
1.3.6.1.4.1.11.2.14.11.5.1.35.2.2.1CompliancehpicfInstMonBaseCompliancecurrentThe compliance statement for HP switches running Instrumentation Monitor and implementing the HP-ICF-INST-MON MIB.
1.3.6.1.4.1.11.2.14.11.5.1.35.2.2.2CompliancehpicfInstConfigCompliancecurrentThe compliance statement for HP switches running Instrumentation collection and implementing the HP-ICF-INST-MON MIB.
1.3.6.1.4.1.11.2.14.11.5.1.35.2.2.3CompliancehpicfInstMonNotifyCompliancecurrentThe compliance statement for HP switches running Instrumentation Monitor.