MIB Viewer

HP-ICF-OPENFLOW-MIB

104 objects
Added all option hpicfOpenFlowInstanceOverrideProtocol mib object.
OIDNameAccessStatusDescription
1.3.6.1.4.1.11.2.14.11.5.1.89IdentityhpicfOpenFlowMIBAdded all option hpicfOpenFlowInstanceOverrideProtocol mib object.
1.3.6.1.4.1.11.2.14.11.5.1.89.0NodehpicfOpenFlowNotifications
1.3.6.1.4.1.11.2.14.11.5.1.89.1NodehpicfOpenFlowObjects
1.3.6.1.4.1.11.2.14.11.5.1.89.1.1ScalarhpicfOpenFlowStatusread-writecurrentGlobal configuration to enable or disable OpenFlow on the device. The 'disableWithClearConfig' enum disables OpenFlow along with removing all the OpenFlow rela…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4TablehpicfOpenFlowInstanceTablenot-accessiblecurrentA table that is used create an OpenFlow instance. For maximum number of OpenFlow instances that can be supported, refer to hpicfOpenFLowMaxInstances MIB object.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1RowhpicfOpenFlowInstanceEntrynot-accessiblecurrentA set of objects that are used to create an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.1ColumnhpicfOpenFlowInstanceNamenot-accessiblecurrentUnique name given to an OpenFlow instance. The instance name 'aggregate' is special case denoting switch functioning as OpenFlow switch. The instance name allo…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.2ColumnhpicfOpenFlowInstanceAdminStatusread-createcurrentThis object is used to administratively enable or disable an OpenFlow instance. This MIB object can be set to 'enable' only when either hpicfOpenFlowInstanceLi…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.3ColumnhpicfOpenFlowInstanceListenPortCfgread-createcurrentThis object indicates if a listen-port is configured on this OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.4ColumnhpicfOpenFlowInstanceListenPortread-createcurrentPort number for the listen-port on the OpenFlow instance. A valid port number is between 1024 and 65534 inclusive.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.5ColumnhpicfOpenFlowInstanceListenPortIsOobmread-createcurrentThis object indicates if a listen-port is configured for this OpenFlow instance over OOBM(Out Of Band Management) interface. This MIB object will be applicable…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.6ColumnhpicfOpenFlowInstanceModeread-createcurrentThis object allows the user to specify the mode of OpenFlow operation for an instance. In active mode, new flows get redirected to the OpenFlow controller. In …
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.7ColumnhpicfOpenFlowInstanceFlowLocationModeread-createcurrentThis object specifies if the flows for this instance will be located in hardware only or in hardware and software. By default, flows will be located in hardwar…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.8ColumnhpicfOpenFlowConnectionInterruptionModeread-createcurrentThis MIB object is used to specify the type of fallback when the switch loses connection with the controller. In fail-secure mode, packets and messages destine…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.9ColumnhpicfOpenFlowInstanceHwRateLimitread-createcurrentThis object limits the bandwidth per module in kilobits per second, that this OpenFlow instance can utilize. This implementation supports a minimum rate limit …
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.10ColumnhpicfOpenFlowInstanceSwRateLimitread-createcurrentThis object limits the number of packets per second for each module, that this instance can send to the software path on the CPU. Increasing the software rate …
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.11ColumnhpicfOpenFlowInstanceDatapathIDread-onlycurrentDatapath ID(DPID) uniquely identifies a datapath between this instance and the controller. Its lower 48-bits are intended for switch MAC address, while the upp…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.12ColumnhpicfOpenFlowInstanceNumOfHwFlowsread-onlycurrentThis object indicates the number of hardware flows in this OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.13ColumnhpicfOpenFlowInstanceNumOfSwFlowsread-onlycurrentThis object indicates the number of software flows in this OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.14ColumnhpicfOpenFlowInstanceOperStatusread-onlycurrentThis object is used to determine the operational state of an OpenFlow instance. The reason for operational status to be down is specified by the hpicfOpenFlowI…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.15ColumnhpicfOpenFlowInstanceMaxBackOffIntervalread-createcurrentInterval between two consecutive attempts made by an instance to reconnect to a controller increases exponentially till it reaches the value specified by this …
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.16ColumnhpicfOpenFlowInstanceRowStatusread-createcurrentRow status for this table.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.17ColumnhpicfOpenFlowInstanceProbeIntervalread-createcurrentThis MIB object specifies the interval between two consecutive probes sent from an instance to the controller. This MIB value also determines how soon the inst…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.18ColumnhpicfOpenFlowInstanceProtoVersionread-createcurrentThis MIB object specifies the OpenFlow instance protocol version.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.19ColumnhpicfOpenFlowInstanceProtoVersionOnlyread-createcurrentSetting this MIB object to true will support only the specific version mentioned by hpicfOpenFlowInstanceProtoVersion MIB and not compatible with lower version…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.20ColumnhpicfOpenFlowInstanceNumOfSwFlowTableread-createcurrentThis MIB object specifies the number of software flow tables for this OpenFlow instance. The maximum value supported is 8. This object is applicable only for a…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.21ColumnhpicfOpenFlowInstanceOperStatusReasonread-onlycurrentThis MIB object specifies the reason for hpicfOpenFlowInstanceOperStatus to be down.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.22ColumnhpicfOpenFlowInstanceEgressOnlyPortsread-onlycurrentThis MIB object specifies the list of egress only ports for this OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.23ColumnhpicfOpenFlowInstanceCapabilitiesread-onlycurrentThis MIB object specifies the instance capabilities exchanged with the controller.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.24ColumnhpicfOpenFlowInstanceHwTableMissCountread-onlycurrentThis MIB object specifies the number of packets which do not match any rules in the hardware table. This object is applicable only for an OpenFlow version 1.0 …
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.25ColumnhpicfOpenFlowInstanceTableModelread-onlycurrentThis MIB object determines the table model of an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.26ColumnhpicfOpenFlowInstanceMembersread-writecurrentThis MIB object is used to add member VLANs to an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.27ColumnhpicfOpenFlowInstancePipelineModelread-writecurrentThis MIB object is used to configure the openflow instance pipeline model. A value of 0(none) indicates no table pipeline model which is equal to standard matc…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.28ColumnhpicfOpenFlowInstanceDatapathDescread-writecurrentThis MIB object is a user-defined description of the data path. If not set, hpicfOpenFlowInstanceName is used.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.29ColumnhpicfOpenFlowInstanceSourceMacGrpTableread-createcurrentThis object is used to enable or disable the source MAC group table in the OpenFlow pipeline. This MIB object can be set to 'enable' only on one instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.30ColumnhpicfOpenFlowInstanceDestMacGrpTableread-createcurrentThis object is used to enable or disable the destination MAC group table in the OpenFlow table. This MIB object can be set to 'enable' only on one instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.31ColumnhpicfOpenFlowInstanceMissRuleDefaultActionread-writecurrentThis MIB object is used to configure the flow miss action associated with the instance. A value of 0(none) indicates no flow miss action specified, which is to…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.32ColumnhpicfOpenFlowInstanceOverrideProtocolread-writecurrentThis MIB object is used to configure the Override protocol associated with the instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.33ColumnhpicfOpenFlowInstancePktInVlanTaggingread-writecurrentThis MIB object is used to configure the 802.1q tagging property for a packet encapsulated inside the OpenFlow packet-in header. A value of 0 (default) indicat…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.5TablehpicfOpenFlowInstanceMembershipTablenot-accessibledeprecatedTable used to add members to OpenFlow instances. This table is deprecated and instead object hpicfOpenFlowInstanceMembers is used to configure members for an O…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.5.1RowhpicfOpenFlowInstanceMembershipEntrynot-accessibledeprecatedA set of objects that are used to add members to an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.5.1.2ColumnhpicfOpenFlowInstanceMembershipRowStatusread-createdeprecatedRow status for this member.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6TablehpicfOpenFlowControllerTablenot-accessiblecurrentTable used to configure controllers. For maximum number of OpenFlow controllers that can be supported, refer to hpicfOpenFlowMaxControllers MIB object.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1RowhpicfOpenFlowControllerEntrynot-accessiblecurrentA set of objects that are used to configure OpenFlow Controllers.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.1ColumnhpicfOpenFlowControllerIDnot-accessiblecurrentUnique ID given to a Controller. This will be associated with an instance through hpicfOpenFlowInstanceControllerTable.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.2ColumnhpicfOpenFlowControllerInetAddressTyperead-createcurrentAddress type of this controller. This implementation supports only ipv4 type.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.3ColumnhpicfOpenFlowControllerInetAddressread-createcurrentIP Address of the controller.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.4ColumnhpicfOpenFlowControllerPortread-createcurrentThe port over which the controller can be reached.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.5ColumnhpicfOpenFlowControllerInterfaceread-createcurrentThis MIB object specifies an interface over which the controller is reachable.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.6ColumnhpicfOpenFlowControllerRowStatusread-createcurrentRow status for this table. The hpicfOpenFlowControllerInetAddress and hpicfOpenFlowControllerInterface MIB objects have to be set to valid values to move this …
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.7ColumnhpicfOpenFlowControllerSourceAddressTyperead-createcurrentAddress type of the Source IP. This implementation supports only ipv4 type.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.8ColumnhpicfOpenFlowControllerSourceAddressread-createcurrentSource IP address to use when connecting to the controller.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.8TablehpicfOpenFlowInstanceControllerTablenot-accessiblecurrentTable that contains objects for connection state and status between an OpenFlow instance and a controller.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1RowhpicfOpenFlowInstanceControllerEntrynot-accessiblecurrentA set of objects used to monitor the status and state of connection between an OpenFlow instance and controller.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.1ColumnhpicfOpenFlowInstanceControllerStatusread-onlycurrentConnection status between an OpenFlow instance and a controller.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.2ColumnhpicfOpenFlowInstanceControllerStateread-onlycurrentConnection state between an OpenFlow instance and a controller. The state 'void' implies that there is no connection. The state 'backoff' represents a state wh…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.3ColumnhpicfOpenFlowInstanceControllerRoleread-onlycurrentRole of a controller in an instance. The default role of a controller is equal. In this role, the controller has full access to the switch and is equal to othe…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.4ColumnhpicfOpenFlowInstanceControllerConnSecureread-createcurrentThis object indicates if the connection between the controller and instance is secure. Setting this MIB to true will initiate TLS as transport protocol.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.5ColumnhpicfOpenFlowInstanceControllerRowStatusread-createcurrentRow status for this table. Row transition to 'createAndWait', 'notReady' and 'notInService' states are not allowed.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.10ScalarhpicfOpenFlowMaxInstancesread-onlycurrentThis MIB object specifies the maximum number of OpenFlow instances.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.11ScalarhpicfOpenFlowMaxFlowsread-onlycurrentThis MIB objects specifies the total number of flows that can be supported on the switch. That is, the sum of all hardware flows and software flows across all …
1.3.6.1.4.1.11.2.14.11.5.1.89.1.12ScalarhpicfOpenFlowMaxControllersread-onlycurrentThis MIB object specifies the maximum number of OpenFlow controllers.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.19TablehpicfOpenFlowInstanceMeterTablenot-accessiblecurrentTable that contains objects related to meters of an OpenFlow instance. This table is populated when meters are configured from controller.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1RowhpicfOpenFlowInstanceMeterEntrynot-accessiblecurrentA set of objects used to retrieve details about meters associated with an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.1ColumnhpicfOpenFlowInstanceMeterIDnot-accessiblecurrentUnique ID given to a meter.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.2ColumnhpicfOpenFlowInstanceMeterFlowCountread-onlycurrentNumber of flows on which this meter is applied.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.3ColumnhpicfOpenFlowInstanceMeterInputPktCountread-onlycurrentNumber of packets processed by this meter.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.4ColumnhpicfOpenFlowInstanceMeterInputByteCountread-onlycurrentNumber of bytes processed by this meter.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.5ColumnhpicfOpenFlowInstanceMeterDurationread-onlycurrentDuration for which this meter is active.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.20TablehpicfOpenFlowInstanceMeterBandTablenot-accessiblecurrentTable that contains objects related to meter bands for a specific meter in an OpenFlow instance. This table is populated when meters and their bands are config…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1RowhpicfOpenFlowInstanceMeterBandEntrynot-accessiblecurrentA set of objects used to retrieve details about meter bands associated with a meter and an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.1ColumnhpicfOpenFlowInstanceMeterBandIDnot-accessiblecurrentUnique ID given to a band in a meter.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.2ColumnhpicfOpenFlowInstanceMeterBandTyperead-onlycurrentThis meter band type determines how the packets are processed.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.3ColumnhpicfOpenFlowInstanceMeterBandRateread-onlycurrentThis MIB object specifies the rate beyond which the incoming packets would be treated according to action specified by hpicfOpenFlowInstanceMeterBandType MIB. …
1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.4ColumnhpicfOpenFlowInstanceMeterBandRateUnitread-onlycurrentThis MIB object specifies the unit for hpicfOpenFlowInstanceMeterBandRate MIB. The units can be either kilobits per second or packets per second.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.5ColumnhpicfOpenFlowInstanceMeterInBandPktCountread-onlycurrentNumber of packets processed by this meter.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.6ColumnhpicfOpenFlowInstanceMeterInBandByteCountread-onlycurrentNumber of bytes processed by this meter.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.7ColumnhpicfOpenFlowInstanceMeterPrecedenceLevelread-onlycurrentDSCP Precedence level of the band in a meter.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.21NodehpicfOpenFlowScalarObjects
1.3.6.1.4.1.11.2.14.11.5.1.89.1.21.1ScalarhpicfOpenFlowIPControlTableUsageread-writecurrentThis object is used to specify maximum percentage of IP control table resources that can be used by OpenFlow. The percentage is not a guarantee, but a maximum …
1.3.6.1.4.1.11.2.14.11.5.1.89.1.21.2ScalarhpicfOpenFlowIPControlTableStatsRefreshRateread-onlycurrentThis MIB object is used to specify the time interval at which the hardware will be polled for statistics. A value of '0' would mean that the hardware will no l…
1.3.6.1.4.1.11.2.14.11.5.1.89.1.21.9ScalarhpicfOpenFlowIpControlTableModeread-writedeprecatedThis MIB object specifies the OpenFlow operation mode. In this mode, IP control table would be advertised by an OpenFlow 1.3 instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.1.21.10ScalarhpicfOpenFlowEgressOnlyPortsread-writecurrentSetting this MIB object to 'enable' will advertise egress-only ports to the controller.
1.3.6.1.4.1.11.2.14.11.5.1.89.2NodehpicfOpenFlowConformance
1.3.6.1.4.1.11.2.14.11.5.1.89.2.1NodehpicfOpenFlowCompliances
1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.1CompliancehpicfOpenFlowCompliancedeprecatedThis compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro…
1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.2CompliancehpicfOpenFlowCompliance1deprecatedThis compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro…
1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.3CompliancehpicfOpenFlowCompliance2deprecatedThis compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro…
1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.4CompliancehpicfOpenFlowCompliance3deprecatedThis compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro…
1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.5CompliancehpicfOpenFlowCompliance4currentThis compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro…
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2NodehpicfOpenFlowGroups
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.1GrouphpicfOpenFlowGlobalConfigGroupcurrentControls the global configuration of OpenFlow status and allocation of policy engine resource.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.2GrouphpicfOpenFlowInstanceGroupdeprecatedA collection of objects used to define an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.3GrouphpicfOpenFlowInstanceMembershipGroupdeprecatedAn object used to associate a member to an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.4GrouphpicfOpenFlowControllerGroupdeprecatedA collection of objects used to define controllers.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.6GrouphpicfOpenFlowInstanceControllerGroupcurrentA set of objects used to monitor the status and state of an OpenFlow Instance and controller connection.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.13GrouphpicfOpenFlowInstanceMeterGroupcurrentA collection of objects used to retrieve details about instance-specific meters.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.14GrouphpicfOpenFlowInstanceMeterBandGroupcurrentA collection of objects used to retrieve details about meter band types.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.15GrouphpicfOpenFlowScalarsGroupdeprecatedBasic Scalars required for OpenFlow implementation.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.16GrouphpicfOpenFlowInstanceGroup1deprecatedA collection of objects used to define an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.17GrouphpicfOpenFlowScalarsGroup1currentBasic Scalars required for OpenFlow implementation.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.20GrouphpicfOpenFlowInstanceGroup2deprecatedA collection of objects used to define an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.21GrouphpicfOpenFlowInstanceGroup3currentA collection of objects used to define an OpenFlow instance.
1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.22GrouphpicfOpenFlowControllerGroup1currentA collection of objects used to define controllers.