HP-ICF-OPENFLOW-MIB
104 objects
Added all option hpicfOpenFlowInstanceOverrideProtocol mib object.
Imported Objects
| HP-ICF-OID | hpSwitch |
| HP-ICF-TC | VidList |
| IF-MIB | ifIndex InterfaceIndex |
| INET-ADDRESS-MIB | InetAddress InetAddressType InetPortNumber |
| Q-BRIDGE-MIB | PortList |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | Counter64 Integer32 MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DisplayString RowStatus TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.5.1.89 | IdentityhpicfOpenFlowMIB | Added all option hpicfOpenFlowInstanceOverrideProtocol mib object. | ||
| 1.3.6.1.4.1.11.2.14.11.5.1.89.0 | NodehpicfOpenFlowNotifications | |||
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1 | NodehpicfOpenFlowObjects | |||
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.1 | ScalarhpicfOpenFlowStatus | read-write | current | Global configuration to enable or disable OpenFlow on the device. The 'disableWithClearConfig' enum disables OpenFlow along with removing all the OpenFlow rela… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4 | TablehpicfOpenFlowInstanceTable | not-accessible | current | A table that is used create an OpenFlow instance. For maximum number of OpenFlow instances that can be supported, refer to hpicfOpenFLowMaxInstances MIB object. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1 | RowhpicfOpenFlowInstanceEntry | not-accessible | current | A set of objects that are used to create an OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.1 | ColumnhpicfOpenFlowInstanceName | not-accessible | current | Unique name given to an OpenFlow instance. The instance name 'aggregate' is special case denoting switch functioning as OpenFlow switch. The instance name allo… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.2 | ColumnhpicfOpenFlowInstanceAdminStatus | read-create | current | This object is used to administratively enable or disable an OpenFlow instance. This MIB object can be set to 'enable' only when either hpicfOpenFlowInstanceLi… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.3 | ColumnhpicfOpenFlowInstanceListenPortCfg | read-create | current | This object indicates if a listen-port is configured on this OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.4 | ColumnhpicfOpenFlowInstanceListenPort | read-create | current | Port number for the listen-port on the OpenFlow instance. A valid port number is between 1024 and 65534 inclusive. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.5 | ColumnhpicfOpenFlowInstanceListenPortIsOobm | read-create | current | This object indicates if a listen-port is configured for this OpenFlow instance over OOBM(Out Of Band Management) interface. This MIB object will be applicable… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.6 | ColumnhpicfOpenFlowInstanceMode | read-create | current | This object allows the user to specify the mode of OpenFlow operation for an instance. In active mode, new flows get redirected to the OpenFlow controller. In … |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.7 | ColumnhpicfOpenFlowInstanceFlowLocationMode | read-create | current | This object specifies if the flows for this instance will be located in hardware only or in hardware and software. By default, flows will be located in hardwar… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.8 | ColumnhpicfOpenFlowConnectionInterruptionMode | read-create | current | This MIB object is used to specify the type of fallback when the switch loses connection with the controller. In fail-secure mode, packets and messages destine… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.9 | ColumnhpicfOpenFlowInstanceHwRateLimit | read-create | current | This object limits the bandwidth per module in kilobits per second, that this OpenFlow instance can utilize. This implementation supports a minimum rate limit … |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.10 | ColumnhpicfOpenFlowInstanceSwRateLimit | read-create | current | This object limits the number of packets per second for each module, that this instance can send to the software path on the CPU. Increasing the software rate … |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.11 | ColumnhpicfOpenFlowInstanceDatapathID | read-only | current | Datapath ID(DPID) uniquely identifies a datapath between this instance and the controller. Its lower 48-bits are intended for switch MAC address, while the upp… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.12 | ColumnhpicfOpenFlowInstanceNumOfHwFlows | read-only | current | This object indicates the number of hardware flows in this OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.13 | ColumnhpicfOpenFlowInstanceNumOfSwFlows | read-only | current | This object indicates the number of software flows in this OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.14 | ColumnhpicfOpenFlowInstanceOperStatus | read-only | current | This object is used to determine the operational state of an OpenFlow instance. The reason for operational status to be down is specified by the hpicfOpenFlowI… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.15 | ColumnhpicfOpenFlowInstanceMaxBackOffInterval | read-create | current | Interval between two consecutive attempts made by an instance to reconnect to a controller increases exponentially till it reaches the value specified by this … |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.16 | ColumnhpicfOpenFlowInstanceRowStatus | read-create | current | Row status for this table. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.17 | ColumnhpicfOpenFlowInstanceProbeInterval | read-create | current | This MIB object specifies the interval between two consecutive probes sent from an instance to the controller. This MIB value also determines how soon the inst… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.18 | ColumnhpicfOpenFlowInstanceProtoVersion | read-create | current | This MIB object specifies the OpenFlow instance protocol version. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.19 | ColumnhpicfOpenFlowInstanceProtoVersionOnly | read-create | current | Setting this MIB object to true will support only the specific version mentioned by hpicfOpenFlowInstanceProtoVersion MIB and not compatible with lower version… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.20 | ColumnhpicfOpenFlowInstanceNumOfSwFlowTable | read-create | current | This MIB object specifies the number of software flow tables for this OpenFlow instance. The maximum value supported is 8. This object is applicable only for a… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.21 | ColumnhpicfOpenFlowInstanceOperStatusReason | read-only | current | This MIB object specifies the reason for hpicfOpenFlowInstanceOperStatus to be down. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.22 | ColumnhpicfOpenFlowInstanceEgressOnlyPorts | read-only | current | This MIB object specifies the list of egress only ports for this OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.23 | ColumnhpicfOpenFlowInstanceCapabilities | read-only | current | This MIB object specifies the instance capabilities exchanged with the controller. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.24 | ColumnhpicfOpenFlowInstanceHwTableMissCount | read-only | current | This MIB object specifies the number of packets which do not match any rules in the hardware table. This object is applicable only for an OpenFlow version 1.0 … |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.25 | ColumnhpicfOpenFlowInstanceTableModel | read-only | current | This MIB object determines the table model of an OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.26 | ColumnhpicfOpenFlowInstanceMembers | read-write | current | This MIB object is used to add member VLANs to an OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.27 | ColumnhpicfOpenFlowInstancePipelineModel | read-write | current | This MIB object is used to configure the openflow instance pipeline model. A value of 0(none) indicates no table pipeline model which is equal to standard matc… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.28 | ColumnhpicfOpenFlowInstanceDatapathDesc | read-write | current | This MIB object is a user-defined description of the data path. If not set, hpicfOpenFlowInstanceName is used. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.29 | ColumnhpicfOpenFlowInstanceSourceMacGrpTable | read-create | current | This object is used to enable or disable the source MAC group table in the OpenFlow pipeline. This MIB object can be set to 'enable' only on one instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.30 | ColumnhpicfOpenFlowInstanceDestMacGrpTable | read-create | current | This object is used to enable or disable the destination MAC group table in the OpenFlow table. This MIB object can be set to 'enable' only on one instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.31 | ColumnhpicfOpenFlowInstanceMissRuleDefaultAction | read-write | current | This MIB object is used to configure the flow miss action associated with the instance. A value of 0(none) indicates no flow miss action specified, which is to… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.32 | ColumnhpicfOpenFlowInstanceOverrideProtocol | read-write | current | This MIB object is used to configure the Override protocol associated with the instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.4.1.33 | ColumnhpicfOpenFlowInstancePktInVlanTagging | read-write | current | This MIB object is used to configure the 802.1q tagging property for a packet encapsulated inside the OpenFlow packet-in header. A value of 0 (default) indicat… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.5 | TablehpicfOpenFlowInstanceMembershipTable | not-accessible | deprecated | Table used to add members to OpenFlow instances. This table is deprecated and instead object hpicfOpenFlowInstanceMembers is used to configure members for an O… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.5.1 | RowhpicfOpenFlowInstanceMembershipEntry | not-accessible | deprecated | A set of objects that are used to add members to an OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.5.1.2 | ColumnhpicfOpenFlowInstanceMembershipRowStatus | read-create | deprecated | Row status for this member. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6 | TablehpicfOpenFlowControllerTable | not-accessible | current | Table used to configure controllers. For maximum number of OpenFlow controllers that can be supported, refer to hpicfOpenFlowMaxControllers MIB object. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1 | RowhpicfOpenFlowControllerEntry | not-accessible | current | A set of objects that are used to configure OpenFlow Controllers. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.1 | ColumnhpicfOpenFlowControllerID | not-accessible | current | Unique ID given to a Controller. This will be associated with an instance through hpicfOpenFlowInstanceControllerTable. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.2 | ColumnhpicfOpenFlowControllerInetAddressType | read-create | current | Address type of this controller. This implementation supports only ipv4 type. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.3 | ColumnhpicfOpenFlowControllerInetAddress | read-create | current | IP Address of the controller. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.4 | ColumnhpicfOpenFlowControllerPort | read-create | current | The port over which the controller can be reached. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.5 | ColumnhpicfOpenFlowControllerInterface | read-create | current | This MIB object specifies an interface over which the controller is reachable. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.6 | ColumnhpicfOpenFlowControllerRowStatus | read-create | current | Row status for this table. The hpicfOpenFlowControllerInetAddress and hpicfOpenFlowControllerInterface MIB objects have to be set to valid values to move this … |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.7 | ColumnhpicfOpenFlowControllerSourceAddressType | read-create | current | Address type of the Source IP. This implementation supports only ipv4 type. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.6.1.8 | ColumnhpicfOpenFlowControllerSourceAddress | read-create | current | Source IP address to use when connecting to the controller. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.8 | TablehpicfOpenFlowInstanceControllerTable | not-accessible | current | Table that contains objects for connection state and status between an OpenFlow instance and a controller. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1 | RowhpicfOpenFlowInstanceControllerEntry | not-accessible | current | A set of objects used to monitor the status and state of connection between an OpenFlow instance and controller. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.1 | ColumnhpicfOpenFlowInstanceControllerStatus | read-only | current | Connection status between an OpenFlow instance and a controller. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.2 | ColumnhpicfOpenFlowInstanceControllerState | read-only | current | Connection state between an OpenFlow instance and a controller. The state 'void' implies that there is no connection. The state 'backoff' represents a state wh… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.3 | ColumnhpicfOpenFlowInstanceControllerRole | read-only | current | Role of a controller in an instance. The default role of a controller is equal. In this role, the controller has full access to the switch and is equal to othe… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.4 | ColumnhpicfOpenFlowInstanceControllerConnSecure | read-create | current | This object indicates if the connection between the controller and instance is secure. Setting this MIB to true will initiate TLS as transport protocol. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.8.1.5 | ColumnhpicfOpenFlowInstanceControllerRowStatus | read-create | current | Row status for this table. Row transition to 'createAndWait', 'notReady' and 'notInService' states are not allowed. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.10 | ScalarhpicfOpenFlowMaxInstances | read-only | current | This MIB object specifies the maximum number of OpenFlow instances. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.11 | ScalarhpicfOpenFlowMaxFlows | read-only | current | This MIB objects specifies the total number of flows that can be supported on the switch. That is, the sum of all hardware flows and software flows across all … |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.12 | ScalarhpicfOpenFlowMaxControllers | read-only | current | This MIB object specifies the maximum number of OpenFlow controllers. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.19 | TablehpicfOpenFlowInstanceMeterTable | not-accessible | current | Table that contains objects related to meters of an OpenFlow instance. This table is populated when meters are configured from controller. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1 | RowhpicfOpenFlowInstanceMeterEntry | not-accessible | current | A set of objects used to retrieve details about meters associated with an OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.1 | ColumnhpicfOpenFlowInstanceMeterID | not-accessible | current | Unique ID given to a meter. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.2 | ColumnhpicfOpenFlowInstanceMeterFlowCount | read-only | current | Number of flows on which this meter is applied. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.3 | ColumnhpicfOpenFlowInstanceMeterInputPktCount | read-only | current | Number of packets processed by this meter. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.4 | ColumnhpicfOpenFlowInstanceMeterInputByteCount | read-only | current | Number of bytes processed by this meter. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.19.1.5 | ColumnhpicfOpenFlowInstanceMeterDuration | read-only | current | Duration for which this meter is active. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.20 | TablehpicfOpenFlowInstanceMeterBandTable | not-accessible | current | Table that contains objects related to meter bands for a specific meter in an OpenFlow instance. This table is populated when meters and their bands are config… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1 | RowhpicfOpenFlowInstanceMeterBandEntry | not-accessible | current | A set of objects used to retrieve details about meter bands associated with a meter and an OpenFlow instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.1 | ColumnhpicfOpenFlowInstanceMeterBandID | not-accessible | current | Unique ID given to a band in a meter. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.2 | ColumnhpicfOpenFlowInstanceMeterBandType | read-only | current | This meter band type determines how the packets are processed. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.3 | ColumnhpicfOpenFlowInstanceMeterBandRate | read-only | current | This MIB object specifies the rate beyond which the incoming packets would be treated according to action specified by hpicfOpenFlowInstanceMeterBandType MIB. … |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.4 | ColumnhpicfOpenFlowInstanceMeterBandRateUnit | read-only | current | This MIB object specifies the unit for hpicfOpenFlowInstanceMeterBandRate MIB. The units can be either kilobits per second or packets per second. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.5 | ColumnhpicfOpenFlowInstanceMeterInBandPktCount | read-only | current | Number of packets processed by this meter. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.6 | ColumnhpicfOpenFlowInstanceMeterInBandByteCount | read-only | current | Number of bytes processed by this meter. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.20.1.7 | ColumnhpicfOpenFlowInstanceMeterPrecedenceLevel | read-only | current | DSCP Precedence level of the band in a meter. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.21 | NodehpicfOpenFlowScalarObjects | |||
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.21.1 | ScalarhpicfOpenFlowIPControlTableUsage | read-write | current | This object is used to specify maximum percentage of IP control table resources that can be used by OpenFlow. The percentage is not a guarantee, but a maximum … |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.21.2 | ScalarhpicfOpenFlowIPControlTableStatsRefreshRate | read-only | current | This MIB object is used to specify the time interval at which the hardware will be polled for statistics. A value of '0' would mean that the hardware will no l… |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.21.9 | ScalarhpicfOpenFlowIpControlTableMode | read-write | deprecated | This MIB object specifies the OpenFlow operation mode. In this mode, IP control table would be advertised by an OpenFlow 1.3 instance. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.1.21.10 | ScalarhpicfOpenFlowEgressOnlyPorts | read-write | current | Setting this MIB object to 'enable' will advertise egress-only ports to the controller. |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2 | NodehpicfOpenFlowConformance | |||
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.1 | NodehpicfOpenFlowCompliances | |||
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.1 | CompliancehpicfOpenFlowCompliance | deprecated | This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro… | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.2 | CompliancehpicfOpenFlowCompliance1 | deprecated | This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro… | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.3 | CompliancehpicfOpenFlowCompliance2 | deprecated | This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro… | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.4 | CompliancehpicfOpenFlowCompliance3 | deprecated | This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro… | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.1.5 | CompliancehpicfOpenFlowCompliance4 | current | This compliance statement is for devices supporting OpenFlow. The basic support for OpenFlow requires implementation of the objects listed in the mandatory gro… | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2 | NodehpicfOpenFlowGroups | |||
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.1 | GrouphpicfOpenFlowGlobalConfigGroup | current | Controls the global configuration of OpenFlow status and allocation of policy engine resource. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.2 | GrouphpicfOpenFlowInstanceGroup | deprecated | A collection of objects used to define an OpenFlow instance. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.3 | GrouphpicfOpenFlowInstanceMembershipGroup | deprecated | An object used to associate a member to an OpenFlow instance. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.4 | GrouphpicfOpenFlowControllerGroup | deprecated | A collection of objects used to define controllers. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.6 | GrouphpicfOpenFlowInstanceControllerGroup | current | A set of objects used to monitor the status and state of an OpenFlow Instance and controller connection. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.13 | GrouphpicfOpenFlowInstanceMeterGroup | current | A collection of objects used to retrieve details about instance-specific meters. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.14 | GrouphpicfOpenFlowInstanceMeterBandGroup | current | A collection of objects used to retrieve details about meter band types. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.15 | GrouphpicfOpenFlowScalarsGroup | deprecated | Basic Scalars required for OpenFlow implementation. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.16 | GrouphpicfOpenFlowInstanceGroup1 | deprecated | A collection of objects used to define an OpenFlow instance. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.17 | GrouphpicfOpenFlowScalarsGroup1 | current | Basic Scalars required for OpenFlow implementation. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.20 | GrouphpicfOpenFlowInstanceGroup2 | deprecated | A collection of objects used to define an OpenFlow instance. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.21 | GrouphpicfOpenFlowInstanceGroup3 | current | A collection of objects used to define an OpenFlow instance. | |
| 1.3.6.1.4.1.11.2.14.11.5.1.89.2.2.22 | GrouphpicfOpenFlowControllerGroup1 | current | A collection of objects used to define controllers. |