MIB Viewer

HPE-PHY-MIB

14 objects
The MIB module describes the private MIB for testing Layer1 interfaces supported by HPE's software and products.
Imported Objects
HPE-MIBnm
IF-MIBifIndex
SNMPv2-SMIMODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCDisplayString TEXTUAL-CONVENTION TimeStamp TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.11.2.90IdentityrlPhyThe MIB module describes the private MIB for testing Layer1 interfaces supported by HPE's software and products.
1.3.6.1.4.1.11.2.90.1NoderlPhyTest
1.3.6.1.4.1.11.2.90.1.1TablerlPhyTestSetTablenot-accessiblecurrent
1.3.6.1.4.1.11.2.90.1.1.1RowrlPhyTestSetEntrynot-accessiblecurrentAn entry containing objects for invoking tests on an interface.
1.3.6.1.4.1.11.2.90.1.1.1.1ColumnrlPhyTestSetTyperead-writecurrentA control variable used to start operator initiated interface tests.1 indicates that no test has been initiated. Only operator initiated interface tests can be…
1.3.6.1.4.1.11.2.90.1.2TablerlPhyTestGetTablenot-accessiblecurrent
1.3.6.1.4.1.11.2.90.1.2.1RowrlPhyTestGetEntrynot-accessiblecurrentAn entry containing results of tests on an interface.
1.3.6.1.4.1.11.2.90.1.2.1.1ColumnrlPhyTestGetTyperead-onlycurrentA control variable used to, 1 to indicate that this test can be done on the specified port, 2 to initiate the test whenever the user wishes
1.3.6.1.4.1.11.2.90.1.2.1.2ColumnrlPhyTestGetStatusread-onlycurrentThis object contains the status of the most recently requested test for operator initiated tests or the value none(1) if no tests have been requested since the…
1.3.6.1.4.1.11.2.90.1.2.1.3ColumnrlPhyTestGetResultread-onlycurrentThis object holds the test result
1.3.6.1.4.1.11.2.90.1.2.1.4ColumnrlPhyTestGetUnitsread-onlycurrentThe test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the…
1.3.6.1.4.1.11.2.90.1.2.1.5ColumnrlPhyTestGetAlarmread-onlycurrentThis object hold the Alarm for this Entry. only Test that have can have alarms use this field, other holds the Value notRelevant(1)
1.3.6.1.4.1.11.2.90.1.2.1.6ColumnrlPhyTestGetTimeStampread-onlycurrentThe time in string (formated DD-MMM-YYYY HH:MM:SS e.g 14-Apr-2002 10:33:31)
Type Definitions
NameSyntaxStatusDescription
RlPhyTestTypeINTEGER { rlPhyTestTableNoTest(1), rlPhyTestTableCableStatus(2), rlPhyTestTableCableFault(3), rlPhyTestTableCableLength(4), rlPhyTestTableTransceiverTemp(5), rlPhyTestTableTransceiverSupply(6), rlPhyTestTableTxBias(7), rlPhyTestTableTxOutput(8), rlPhyTestTableRxOpticalPower(9), rlPhyTestTableDataReady(10), rlPhyTestTableLOS(11), rlPhyTestTableTxFault(12), rlPhyTestTableCableChannel1(13), rlPhyTestTableCableChannel2(14), rlPhyTestTableCableChannel3(15), rlPhyTestTableCableChannel4(16), rlPhyTestTableCablePolarity1(17), rlPhyTestTableCablePolarity2(18), rlPhyTestTableCablePolarity3(19), rlPhyTestTableCablePolarity4(20), rlPhyTestTableCablePairSkew1(21), rlPhyTestTableCablePairSkew2(22), rlPhyTestTableCablePairSkew3(23), rlPhyTestTableCablePairSkew4(24), rlPhyTestTableSFPEepromQualified(25) }currentA value indicating the test to perform.