MIB Viewer

HPIPF02TRAP-MIB

53 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.11Nodehp
1.3.6.1.4.1.11.2Nodenm
1.3.6.1.4.1.11.2.23Nodehpnsa
1.3.6.1.4.1.11.2.23.35NodehpIpfE0Events
1.3.6.1.4.1.11.2.23.45NodehpIpf02Events
1.3.6.1.4.1.11.2.23.45.1ScalarhpIpfEvtDetailStrread-onlymandatoryThis string provides a detailed description of the Event along with variable information.
1.3.6.1.4.1.11.2.23.45.4NodehpTemperature4One of the temperature sensors crossed its upper non-critical threshold.
1.3.6.1.4.1.11.2.23.45.5NodehpTemperature5One of the temperature sensors crossed its upper critical threshold.
1.3.6.1.4.1.11.2.23.45.6NodehpTemperature6One of the temperature sensors crossed its upper non-recoverable threshold.
1.3.6.1.4.1.11.2.23.45.8NodehpEnvironment8One of the voltage sensors crossed its lower critical threshold.
1.3.6.1.4.1.11.2.23.45.9NodehpEnvironment9One of the voltage sensors crossed its lower non-recoverable threshold.
1.3.6.1.4.1.11.2.23.45.10NodehpEnvironment10One of the voltage sensors crossed its upper non-critical threshold.
1.3.6.1.4.1.11.2.23.45.12NodehpEnvironment12One of the voltage sensors crossed its upper non-recoverable threshold - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.26NodehpChassis26The chassis has been opened.
1.3.6.1.4.1.11.2.23.45.113NodehpSystemHW113A SCSI cable has been removed from the hot swap cage.
1.3.6.1.4.1.11.2.23.45.518NodehpECCMemory518Uncorrectable multi-bit ECC error has occurred in memory module
1.3.6.1.4.1.11.2.23.45.699NodehpSystemFW699Machine Check Initiated
1.3.6.1.4.1.11.2.23.45.700NodehpSystemFW700System firmware error
1.3.6.1.4.1.11.2.23.45.704NodehpEnvironment704Voltage fault - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.705NodehpEnvironment705Voltage degraded to non-recoverable level from less severe - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.706NodehpEnvironment706Voltage becomes non-recoverable from either critical level or less severe level - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.707NodehpEnvironment707Voltage absent
1.3.6.1.4.1.11.2.23.45.710NodehpFan710Fan speed lags
1.3.6.1.4.1.11.2.23.45.720NodehpRedundantPower720Power supply failed or disconnected
1.3.6.1.4.1.11.2.23.45.722NodehpRedundantPower722Power supply AC lost
1.3.6.1.4.1.11.2.23.45.726NodehpPowerSupply726A/C Failed, disconnected, or out of range
1.3.6.1.4.1.11.2.23.45.728NodehpEnvironment728Voltage degraded to critical level from less severe - Check all boards with this voltage
1.3.6.1.4.1.11.2.23.45.729NodehpSystemHW729System shut-down or reset caused by sensor reading.
1.3.6.1.4.1.11.2.23.45.730NodehpBmcFirmware730The BMC firmware did not detect the system firmware boot.
1.3.6.1.4.1.11.2.23.45.731NodehpPowerSupply731A/C Failed, disconnected, or out of range
1.3.6.1.4.1.11.2.23.45.732NodehpRedundantPower732The Power supply's sensors detect possible problems
1.3.6.1.4.1.11.2.23.45.733NodehpSystemHW733Cooling unit warning
1.3.6.1.4.1.11.2.23.45.734NodehpSystemHW734Cooling unit failure
1.3.6.1.4.1.11.2.23.45.735NodehpSystemHW735BMC entering special mode
1.3.6.1.4.1.11.2.23.45.736NodehpSystemHW736Watchdog timer expired - hard reset
1.3.6.1.4.1.11.2.23.45.737NodehpSystemHW737Watchdog timer expired - power-off
1.3.6.1.4.1.11.2.23.45.738NodehpSystemHW738Watchdog timer expired - power-cycle
1.3.6.1.4.1.11.2.23.45.739NodehpSystemHW739Missing FRU device
1.3.6.1.4.1.11.2.23.45.740NodehpSystemHW740Missing Entity
1.3.6.1.4.1.11.2.23.45.744NodehpSystemHW744System event log almost full
1.3.6.1.4.1.11.2.23.45.745NodehpSystemHW745TOC interrupt (crash dump)
1.3.6.1.4.1.11.2.23.45.746NodehpSystemHW746INIT Initiated
1.3.6.1.4.1.11.2.23.45.747NodehpSystemHW747PCI system error detected
1.3.6.1.4.1.11.2.23.45.748NodehpSystemHW748OS run-time critical shutdown
1.3.6.1.4.1.11.2.23.45.749NodehpSystemHW749ACPI state S5 (soft-off, entered by override)
1.3.6.1.4.1.11.2.23.45.751NodehpSystemHW751PCI parity error detected
1.3.6.1.4.1.11.2.23.45.752NodehpTempHighWarning752One of the temperature sensors crossed its lower non-critical threshold.
1.3.6.1.4.1.11.2.23.45.753NodehpTempHighCritical753One of the temperature sensors crossed its upper critical threshold.
1.3.6.1.4.1.11.2.23.45.754NodehpTempHighNonRecoverable754One of the temperature sensors crossed its upper non-recoverable threshold.
1.3.6.1.4.1.11.2.23.45.755NodehpTemperature755A temperature inside the server has gone outside the factory specified range.
1.3.6.1.4.1.11.2.23.45.756NodehpTemperature756One of the temperature sensors crossed its upper critical threshold.
1.3.6.1.4.1.11.2.23.45.757NodehpRedundantPower757The Power Supply AC voltage was lost or is out of range.
1.3.6.1.4.1.11.2.23.45.758NodehpRedundantPower758The AC voltage connected to the power supply is out of range.