HPIPFTRAP-MIB

1185 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.11Nodehp
1.3.6.1.4.1.11.2Nodenm
1.3.6.1.4.1.11.2.23Nodehpnsa
1.3.6.1.4.1.11.2.23.35NodehpIpfE0Events
1.3.6.1.4.1.11.2.23.35.1ScalarhpIpfEvtDetailStrread-onlymandatoryThis string provides a detailed description of the Event along with variable information.
1.3.6.1.4.1.11.2.23.35.5001NodehpevtBadOsInitChecksumThe OS has registered an OS_INIT vector, but is has not passed the checksum
1.3.6.1.4.1.11.2.23.35.5002NodehpevtBadOsMcaChecksumThe OS has registered an OS_MCA vector, but it has not passed the checksum
1.3.6.1.4.1.11.2.23.35.5003NodehpevtBootBmcFailedThe BMC has failed testing and has been disabled.
1.3.6.1.4.1.11.2.23.35.5010NodehpevtBootCellLaunchEfiFailureSFW failed to launch EFI
1.3.6.1.4.1.11.2.23.35.5011NodehpevtBootCellMonSelFailureMonarch selection has failed. Data: 0x11 = Calibration Failure 0x22 = Select Code Failure
1.3.6.1.4.1.11.2.23.35.5013NodehpevtBootCellMonarchCollisionMonarch Collision has occurred
1.3.6.1.4.1.11.2.23.35.5023NodehpevtBootCellVirtualizeEfiFailureSFW attempted to virtualize EFI and failed
1.3.6.1.4.1.11.2.23.35.5025NodehpevtBootCellVirtualizePalFailureSFW was unable to virtualize PAL
1.3.6.1.4.1.11.2.23.35.5027NodehpevtBootCellVirtualizeSalFailureSFW was unable to virtualize SAL
1.3.6.1.4.1.11.2.23.35.5028NodehpevtBootCellVirtualizeSalprocFailureSFW was unable to virtualize SALPROC
1.3.6.1.4.1.11.2.23.35.5030NodehpevtBootCpuConfigFailSFW has failed initializing the CPU Struct. Data: Physical location of CPU that produced failure
1.3.6.1.4.1.11.2.23.35.5031NodehpevtBootCpuEarlyConfigFailA CPU has failed early config.
1.3.6.1.4.1.11.2.23.35.5033NodehpevtBootCpuEarlyTestFailA CPU has failed early self test. Data: PAL Test State.
1.3.6.1.4.1.11.2.23.35.5034NodehpevtBootCpuFailedSFW has detected that a CPU has failed. Data: The Physical Location of the CPU that failed
1.3.6.1.4.1.11.2.23.35.5036NodehpevtBootCpuLateTestFailSFW has determined a CPU or Memory has failed late test. This could be related to a CPU error or a Correctable Single Bit Memory error. Data: Physical location…
1.3.6.1.4.1.11.2.23.35.5037NodehpevtBootCpuLateTestInsufficientMemThe CPU late test has failed because of insufficient memory
1.3.6.1.4.1.11.2.23.35.5040NodehpevtBootEfiAllocateErrorCould not allocate memory for EFI image
1.3.6.1.4.1.11.2.23.35.5041NodehpevtBootEfiImageCorruptEFI image is corrupted
1.3.6.1.4.1.11.2.23.35.5042NodehpevtBootEfiNotInFitEFI fit error
1.3.6.1.4.1.11.2.23.35.5045NodehpevtBootEfiNvmFailEFI NVM has failed testing. The cell or system will now halt.
1.3.6.1.4.1.11.2.23.35.5048NodehpevtBootEfiRomBadSizeEFI Image Error
1.3.6.1.4.1.11.2.23.35.5049NodehpevtBootEfiRomXsumErrorEFI Image Error.
1.3.6.1.4.1.11.2.23.35.5050NodehpevtBootExtIntNestLimitedExceededThe IVT interrupting nesting depth has been exceeded. This processor will be halted. Data: Number of the offending vector.
1.3.6.1.4.1.11.2.23.35.5051NodehpevtBootExtIntNotServicedAn external interrupt has been requested and not serviced. Data: Number of the vector
1.3.6.1.4.1.11.2.23.35.5052NodehpevtBootExtIntTakenAn external interrupt has been taken. Data: Number of the vector taken.
1.3.6.1.4.1.11.2.23.35.5053NodehpevtBootFplFailedAccess to the FPL has failed.
1.3.6.1.4.1.11.2.23.35.5054NodehpevtBootGetPsrFailureSFW was unable to read the CPU PSR. Data: Physical location of CPU
1.3.6.1.4.1.11.2.23.35.5055NodehpevtBootHaltCellSFW has halted the cell or system
1.3.6.1.4.1.11.2.23.35.5056NodehpevtBootIncompatiblePalSFW has determined that PAL is not compatible with the current processors.
1.3.6.1.4.1.11.2.23.35.5057NodehpevtBootIncompatibleSlaveSFW has determined that a slave processor is incompatible with the monarch. Data: Physical location of the incompatible processor.
1.3.6.1.4.1.11.2.23.35.5058NodehpevtBootIntrptClearFailureInterrupt clear failed during cell config
1.3.6.1.4.1.11.2.23.35.5059NodehpevtBootIpmiEventFailedSFW has determined that an IPMI event failed.
1.3.6.1.4.1.11.2.23.35.5060NodehpevtBootIvtOffsetData: interrupt vector table (IVT) Offset
1.3.6.1.4.1.11.2.23.35.5063NodehpevtBootLdbStateBadLDB state bad
1.3.6.1.4.1.11.2.23.35.5064NodehpevtBootLostContextIntInterrupt context was lost. Data: interrupt number.
1.3.6.1.4.1.11.2.23.35.5065NodehpevtBootMinStateRegErrorRegistering of the processor min state save area with PAL has failed.
1.3.6.1.4.1.11.2.23.35.5067NodehpevtBootMonarchTimeoutSFW has determined the monarch has timed out. SFW is deconfiguring the CPU. Data: Physical Location of CPU
1.3.6.1.4.1.11.2.23.35.5069NodehpevtBootNoPalBInFitA PAL_B FIT error has occurred
1.3.6.1.4.1.11.2.23.35.5070NodehpevtBootNoSalBInFitA SAL_B FIT error has occurred
1.3.6.1.4.1.11.2.23.35.5073NodehpevtBootNvmFailNVM has failed test. The system will halt
1.3.6.1.4.1.11.2.23.35.5076NodehpevtBootOutOfRangeVectorA interrupt vector has been requested out of the acceptable range. Data: Vector Number.
1.3.6.1.4.1.11.2.23.35.5077NodehpevtBootPalCopyInfoErrorThe PAL Copy Info call has failed.
1.3.6.1.4.1.11.2.23.35.5078NodehpevtBootPalCopyPalErrorError copying PAL to memory
1.3.6.1.4.1.11.2.23.35.5079NodehpevtBootPalProcFailureA PAL Proc has failed. This will halt the processor. Data: Physical Location of CPU
1.3.6.1.4.1.11.2.23.35.5080NodehpevtBootPlatConsoleDevFailedA console device has failed. Data: Physical Addr of device that failed.
1.3.6.1.4.1.11.2.23.35.5081NodehpevtBootPlatIntfcDevFailedA console device has failed. Data: Physical Addr of device that failed.
1.3.6.1.4.1.11.2.23.35.5082NodehpevtBootPlatScrBadPlatform Scratch RAM has failed the test.
1.3.6.1.4.1.11.2.23.35.5083NodehpevtBootRendezFailureA CPU has failed to enter rendezvous. Data: Local CPU Number
1.3.6.1.4.1.11.2.23.35.5084NodehpevtBootSalExtractErrorSFW could not extract SAL_B from the ROM
1.3.6.1.4.1.11.2.23.35.5085NodehpevtBootScrFailPlatform Scratch RAM has failed test.
1.3.6.1.4.1.11.2.23.35.5087NodehpevtBootSelFullIPMI SEL full
1.3.6.1.4.1.11.2.23.35.5091NodehpevtBootSlaveNoFinalWakeupVectorNo wakeup vector registered for processor Data: Physical location of CPU
1.3.6.1.4.1.11.2.23.35.5092NodehpevtBootSlaveRendezHandlerFailSlave Rendezvous handler has failed. Data: Physical Location of CPU
1.3.6.1.4.1.11.2.23.35.5098NodehpevtBootSmbiosBuildErrorSFW failed to build the SMBIOS tables
1.3.6.1.4.1.11.2.23.35.5100NodehpevtBootTrapNestLimitedExceededThe trap nesting limit has been exceeded. Data: Vector Number
1.3.6.1.4.1.11.2.23.35.5101NodehpevtBootTrapNotServicedA trap has been requested and not serviced. Data: Vector Number
1.3.6.1.4.1.11.2.23.35.5102NodehpevtBootTrapTakenA trap has been taken. Data: Number of the vector taken.
1.3.6.1.4.1.11.2.23.35.5103NodehpevtBootUnclearedIntAt least one interrupt was not cleared. Data: The highest pending interrupt number
1.3.6.1.4.1.11.2.23.35.5104NodehpevtBootUnexpectedExtIntPostRedirTableAn unexpected external interrupt has occurred. Data: External Interrupt Number
1.3.6.1.4.1.11.2.23.35.5105NodehpevtBootUnexpectedIntPreRedirTableAn interrupt has occurred before setting up the Interrupt Vector Table. Data: Interrupt Number
1.3.6.1.4.1.11.2.23.35.5106NodehpevtBootUnexpectedMcaAn unexpected MCA has occurred before MCAs are unmasked. Data: Local CPU Number.
1.3.6.1.4.1.11.2.23.35.5107NodehpevtBootUnexpectedTrapPostRedirTableAn unexpected trap has occurred. The trap number is either invalid or the requested trap has not been registered. Data: Trap Number
1.3.6.1.4.1.11.2.23.35.5108NodehpevtBootUnknownFailureSFW has detected an unknown error.
1.3.6.1.4.1.11.2.23.35.5118NodehpevtErrorsPalFailureSFW has detected a PAL Failure
1.3.6.1.4.1.11.2.23.35.5119NodehpevtExpMcNotRegisteredExpected Machine Check Vector not registered
1.3.6.1.4.1.11.2.23.35.5121NodehpevtInitInitiatedThis is the equivalent of a TOC event in the PA RISC Architecture. On IPF systems, this event is called an INIT. This event can be triggered by the 'tc' comman…
1.3.6.1.4.1.11.2.23.35.5123NodehpevtIoCheckLbaMissingErrAn I/O host bridge is missing. Firmware will continue boot and display the following EFI warning, 'Unexpected hardware I/O configuration.' Data Field: Physical…
1.3.6.1.4.1.11.2.23.35.5124NodehpevtIoCheckNumSlotsErrFirmware detected an unexpected number of I/O slots connected to an I/O host bridge. Firmware display the following EFI warning message, 'Unexpected hardware I…
1.3.6.1.4.1.11.2.23.35.5125NodehpevtIoCheckRopeWidthErrFirmware found an I/O controller rope of unexpected width. Firmware will configure the I/O host bridge connected to the rope and display the following EFI warn…
1.3.6.1.4.1.11.2.23.35.5127NodehpevtIoCheckXtraLbaFoundErrFirmware found an unexpected I/O host bridge. Firmware will configure the I/O host bridge and display the following EFI warning message, 'Unexpected hardware I…
1.3.6.1.4.1.11.2.23.35.5130NodehpevtIoDllErrorAn I/O host bridge's bus frequency DLL circuit failed. Firmware will deconfigure the failed I/O host bridge and display the following EFI warning message, 'Fai…
1.3.6.1.4.1.11.2.23.35.5131NodehpevtIoHotPlugCtrlFailedAn I/O host bridge's hot-plug controller has failed. Firmware will deconfigure the I/O host bridge and display the following EFI warning message, 'Failed I/O s…
1.3.6.1.4.1.11.2.23.35.5132NodehpevtIoInvalidRopeBundleFirmware attempts to configure an I/O controller rope to an unsupported width. Firmware will deconfigure any I/O host bridge connected to the rope. Data Field:…
1.3.6.1.4.1.11.2.23.35.5133NodehpevtIoLbaClearErrFailedDuring I/O host bridge configuration, firmware found a persistent error condition. Firmware will deconfigure the I/O host bridge and display the following EFI …
1.3.6.1.4.1.11.2.23.35.5136NodehpevtIoLbaResetErrorAn I/O host bridge is inaccessible because an I/O controller rope reset failed to complete. Firmware will deconfigure the I/O host bridge and display the follo…
1.3.6.1.4.1.11.2.23.35.5137NodehpevtIoNotEnoughPowerErrorThere is insufficient power. Firmware will not power on a hot-plug I/O slot. In addition, firmware will display the following EFI warning message, 'Failed I/O …
1.3.6.1.4.1.11.2.23.35.5138NodehpevtIoPciMappingFailedFirmware encountered an unexpected error while attempting to configure an I/O host bridge's I/O devices. Firmware will continue boot but will not configure the…
1.3.6.1.4.1.11.2.23.35.5139NodehpevtIoPciMappingTooBigThe total resource requirement from the I/O devices connected to an I/O host bridge exceeds the resource limit of the I/O host bridge. Firmware will continue b…
1.3.6.1.4.1.11.2.23.35.5140NodehpevtIoPciUnmappingFailedFirmware encountered an unexpected error while attempting to clear resource allocations on an I/O host bridge's I/O devices. Data Field: Physical location of t…
1.3.6.1.4.1.11.2.23.35.5141NodehpevtIoPcixcapSampleErrorAn I/O host bridge failed to determine the appropriate PCI[X] mode and frequency (PCI, PCI-X 66 MHz, PCI-X 133 MHz, etc.) for its bus. Firmware will deconfigur…
1.3.6.1.4.1.11.2.23.35.5142NodehpevtIoPmNotRespondingErrorFirmware is unable to access the power monitor. Firmware will assume that there is sufficient power and proceed to power on an I/O slot. Data Field: Physical l…
1.3.6.1.4.1.11.2.23.35.5143NodehpevtIoRopeResetErrorAn I/O controller rope reset did not complete within the expected time limit. Firmware will deconfigure the I/O host bridge attached to the rope. Data Field: P…
1.3.6.1.4.1.11.2.23.35.5144NodehpevtIoSbaClearErrFailedDuring I/O chipset configuration, firmware found a persistent error condition. Firmware will attempt to continue the boot. Data Field: Physical location of the…
1.3.6.1.4.1.11.2.23.35.5145NodehpevtIoSlotPowerDefaultErrorDuring boot, firmware has found a hot-plug I/O slot with an incorrect default power state. The slot power should be off by default. Data Field: Physical locati…
1.3.6.1.4.1.11.2.23.35.5146NodehpevtIoSlotPowerOnErrorFirmware encountered an error while attempting to power on an I/O slot. Firmware will deconfigure the I/O slot and display the following EFI warning message, '…
1.3.6.1.4.1.11.2.23.35.5147NodehpevtIoSlotStandbyPowerErrorAn I/O slot's standby (Vaux) power has failed. Firmware will deconfigure the I/O slot and display the following EFI warning message, 'Failed I/O slot(s) deconf…
1.3.6.1.4.1.11.2.23.35.5148NodehpevtIoUnknownPcixcapValAn I/O host bridge or hot-plug controller reported an illegal PCI[X] bus mode for its bus or slot, respectively. Firmware will deconfigure the I/O host bridge …
1.3.6.1.4.1.11.2.23.35.5149NodehpevtIoUnsupRopeFreqFirmware attempted to configure an I/O controller rope to an unsupported frequency. Firmware will deconfigure any I/O host bridge connected to the rope and dis…
1.3.6.1.4.1.11.2.23.35.5150NodehpevtIoUnsupportedLbaFirmware has found an unsupported I/O host bridge type. Firmware will deconfigure the I/O host bridge and display the following EFI warning message, 'Failed I/…
1.3.6.1.4.1.11.2.23.35.5152NodehpevtMcInitiatedA Machine Check has been initiated
1.3.6.1.4.1.11.2.23.35.5155NodehpevtMdtConstructAreaBadThere has been a problem building the Memory Data Table (MDT).
1.3.6.1.4.1.11.2.23.35.5156NodehpevtMdtLmmioEntryNotFoundThere has been a problem building the Memory Data Table (MDT).
1.3.6.1.4.1.11.2.23.35.5157NodehpevtMdtPageZeroBadMemory page 0 was slated for deallocation in the PDT. EFI cannot launch with page 0 bad, so the system will halt.
1.3.6.1.4.1.11.2.23.35.5158NodehpevtMdtUnableToFindSpaceThere has been a problem building the Memory Data Table (MDT).
1.3.6.1.4.1.11.2.23.35.5159NodehpevtMediaFailureThere has been a media failure.
1.3.6.1.4.1.11.2.23.35.5160NodehpevtMemBibRegFailureIndicates that the chipset register test has failed. The data field contains the physical address of the failing register.
1.3.6.1.4.1.11.2.23.35.5161NodehpevtMemCacheLine0WrRdFailedAfter FW's first access to main memory, FW detected that the CEC logged an error after reading back what was just written.
1.3.6.1.4.1.11.2.23.35.5171NodehpevtMemDimmLoadOrderErrA DIMM that is required to be loaded in order for this DIMM to function properly is not loaded, so FW will deallocate this DIMM. Currently, none of the platfor…
1.3.6.1.4.1.11.2.23.35.5172NodehpevtMemDimmSpdChecksumThe DIMM specified by the physical location has an SPD EEPROM that has a bad checksum. The Data field is the physical location of the DIMM.
1.3.6.1.4.1.11.2.23.35.5173NodehpevtMemDimmSpdFatalDetected a error in DIMM SPD
1.3.6.1.4.1.11.2.23.35.5174NodehpevtMemDimmTypeIncompatibleA DIMM was installed whose DIMM type is not compatible with the current set of supported DIMMs for this platform.
1.3.6.1.4.1.11.2.23.35.5175NodehpevtMemDimmTypeMismatchThe DIMM type of this DIMM is not the same as the other DIMMs in the same group. The group of DIMMs is deallocated. If this is the last active group of DIMMs i…
1.3.6.1.4.1.11.2.23.35.5176NodehpevtMemDimmTypeTableFullThe DIMM type table is full
1.3.6.1.4.1.11.2.23.35.5179NodehpevtMemDmtEntryNotFoundAn entry for the DIMM was not found in the DMT table. The data field contains the DMT entry that the caller wanted to find (in Dimm number format, which is 2 b…
1.3.6.1.4.1.11.2.23.35.5180NodehpevtMemEccMbeDataTstFailedThe FW selftest of CEC multi-bit error (MBE) detection has failed. The upper 32 bits of the data field contain the Dword offset within the cacheline of the fai…
1.3.6.1.4.1.11.2.23.35.5181NodehpevtMemEccMbeSignalTstFailedThe FW selftest of CEC multi-bit error (MBE) signaling has failed. The upper 32 bits of the data field contain the Dword offset within the cacheline of the fai…
1.3.6.1.4.1.11.2.23.35.5182NodehpevtMemEccSbeDataTstFailedThe FW selftest of CEC single-bit error (SBE) detection has failed. The data field contains the bit within the Dword that was flipped that caused the CEC to no…
1.3.6.1.4.1.11.2.23.35.5183NodehpevtMemEccSbeEccTstFailedThe FW selftest of CEC single-bit error (SBE) detection has failed. The data field contains the bit within the Dword that was flipped that caused the CEC to no…
1.3.6.1.4.1.11.2.23.35.5185NodehpevtMemEnoughMemFailedMemory FW detected errors below 1MB. FW will not allow boot in this case, so memory FW will reinterleave and retest.
1.3.6.1.4.1.11.2.23.35.5186NodehpevtMemErrAddrNotInMbatMemory FW could not figure out which rank maps to the physical address specified in the data field.
1.3.6.1.4.1.11.2.23.35.5187NodehpevtMemErrClearFailMemory FW was unable to clear the platform error logs on the CEC. The Datafield contains the error status of the CEC.
1.3.6.1.4.1.11.2.23.35.5189NodehpevtMemErrLogFailedToClearMemory FW was unable to clear the platform error logs on the CEC. The Datafield contains the error status of the CEC.
1.3.6.1.4.1.11.2.23.35.5190NodehpevtMemErrorRegClearFailureThe Error registers in the CEC have failed to clear. The data field contains the error status of the CEC after the attempted clear.
1.3.6.1.4.1.11.2.23.35.5191NodehpevtMemExtFatalLoadOrdErrA DIMM that is required to be loaded in order for this DIMM to function properly is not loaded, so FW will deallocate this DIMM. Currently, none of the platfor…
1.3.6.1.4.1.11.2.23.35.5193NodehpevtMemFirmwareProbAn error occurred that memory FW does not know how to handle.
1.3.6.1.4.1.11.2.23.35.5199NodehpevtMemInterleaveCodeFailureThe memory interleaving code failed.
1.3.6.1.4.1.11.2.23.35.5202NodehpevtMemMainMemFailedFW was unable to create a memory configuration with no errors in low memory to hand off to EFI.
1.3.6.1.4.1.11.2.23.35.5204NodehpevtMemMbeInRankA series of MEM_MBE_IN_RANK chassis code will be sent when an error is detected by firmware. The data fields will contain information on the error based on the…
1.3.6.1.4.1.11.2.23.35.5205NodehpevtMemMcRegFailureThe chipset's memory controller failed the register test. The data field contains the address of the register that failed selftest.
1.3.6.1.4.1.11.2.23.35.5208NodehpevtMemNoDimmsInstalledMemory Discovery could not detect any DIMMs installed.
1.3.6.1.4.1.11.2.23.35.5209NodehpevtMemNoMemFoundFW could not continue because there are no valid memory ranks loaded.
1.3.6.1.4.1.11.2.23.35.5211NodehpevtMemPdtDisabledHaltThe PDT has been disabled, and FW found memory errors during selftest. This is a stopboot condition. Also, the PDT will never be disabled in customer systems, …
1.3.6.1.4.1.11.2.23.35.5212NodehpevtMemPdtDisabledWarningAn event indicating that the user has the PDT disabled on this boot. The PDT will never be disabled in customer systems, so this event should never be seen in …
1.3.6.1.4.1.11.2.23.35.5214NodehpevtMemPdtNvmErrError writing entry into the PDT.
1.3.6.1.4.1.11.2.23.35.5216NodehpevtMemPdtTableFullAn attempt was made to add an entry to a full PDT. The entry is not added, and this event is sent.
1.3.6.1.4.1.11.2.23.35.5218NodehpevtMemPlatformInitFailureMemory FW was unable to save or restore the original error configuration (including CEC error log and signal enable and CPU ECC detection). This event should n…
1.3.6.1.4.1.11.2.23.35.5219NodehpevtMemRankEntryNotFoundThe rank structure that corresponds to the rankID in the data field could not be found in the Rank table. The Data field is the rankID of the structure it is l…
1.3.6.1.4.1.11.2.23.35.5237NodehpevtMemTestExcessMcBitsMore than one error type was detected when only one error type was expected.
1.3.6.1.4.1.11.2.23.35.5238NodehpevtMemTestFwdProgBitsInvalidThe forward progress bits that memory FW uses to track state are invalid. The data field is the fwd progress field.
1.3.6.1.4.1.11.2.23.35.5244NodehpevtMemTestStatusBitsInvalidThe memory error status has bits set in it that indicate another non-memory error occurred. The data field contains the CEC's error status.
1.3.6.1.4.1.11.2.23.35.5245NodehpevtMemTestSummaryBitsInvalidThe memory test summary bits are invalid. The data field is the test summary bits.
1.3.6.1.4.1.11.2.23.35.5248NodehpevtMemUnexpectedMcaMemory rank shadowing has been selected but is not supported by the revision of the memory controller.
1.3.6.1.4.1.11.2.23.35.5250NodehpevtMemWarnDistributionCheckBypassThe control bit to skip the DIMM distribution check is set and the DIMM distribution check was skipped. This bit should only be done in the factory and not in …
1.3.6.1.4.1.11.2.23.35.5252NodehpevtMemWarnLoadingOrderBypassThe control bit to skip the DIMM loading order check is set and the DIMM loading order check was skipped. This bit should only be done in the factory and not i…
1.3.6.1.4.1.11.2.23.35.5253NodehpevtMemWarnLoopOnDestTestThe control bit to loop on destructive memory test is set and the destructive memory tests are run continuously. This bit should only be done in the factory an…
1.3.6.1.4.1.11.2.23.35.5255NodehpevtMemWarnSetCheckBypassThe control bit to skip the DIMM set check is set and the DIMM set check was skipped. This bit should only be done in the factory and not in the field.
1.3.6.1.4.1.11.2.23.35.5256NodehpevtMemWarnSpdBypassThe control bit to skip the DIMM SPD check is set and the checking of the DIMM SPD was skipped. This bit should only be done in the factory and not in the fiel…
1.3.6.1.4.1.11.2.23.35.5257NodehpevtMemWarnUsingAltConfigThe control bit to load an alternate memory configuration is set and an alternate memory configuration has been loaded. This bit should only be set in the fact…
1.3.6.1.4.1.11.2.23.35.5260NodehpevtOsInitNotRegisteredThe OS_INIT vector has not been registered
1.3.6.1.4.1.11.2.23.35.5263NodehpevtOsMcaNotRegisteredThe OS_MCA vector has not been registered
1.3.6.1.4.1.11.2.23.35.5264NodehpevtOsMcaUncorrectedMcAn Uncorrected Machine Check has occurred
1.3.6.1.4.1.11.2.23.35.5266NodehpevtPdhMiscRegFailA PDH register has failed.
1.3.6.1.4.1.11.2.23.35.5268NodehpevtSalCheckUnknownFailThe handler for SAL_CHECK has failed for an unknown reason.
1.3.6.1.4.1.11.2.23.35.5270NodehpevtSalInitUnknownFailThe handler for SAL_INIT has failed for an unknown reason.
1.3.6.1.4.1.11.2.23.35.5278NodehpevtUndefinedSmcInterleaveErrIndicates that FW encountered a Fatal interleaving error. The data field contains the return status from the interleaving procedure call.
1.3.6.1.4.1.11.2.23.35.5279NodehpevtUnexpectedRetToSalCheckUnexpected return to SAL_CHECK.
1.3.6.1.4.1.11.2.23.35.5280NodehpevtUnexpectedRetToSalInitThe SFW TOC vector (SAL_INIT) has been unexpectedly returned to.
1.3.6.1.4.1.11.2.23.35.5335NodehpevtFwInstalledCpuDegradedFirmware is adding a device tree node for a CPU that is degraded in functionality. The cpu should not be trusted and will not be active in the system.
1.3.6.1.4.1.11.2.23.35.5354NodehpevtPdRendezTreeErrorFirmware was unable to locate a required element in the device tree and cannot create a partition. The resource that cannot be located is listed as an ansi str…
1.3.6.1.4.1.11.2.23.35.5359NodehpevtPdCellConfigErrorThe currently executing cell is not configured to be part of the cell set it is attempting to rendezvous with.
1.3.6.1.4.1.11.2.23.35.5360NodehpevtPdRemoteCsrReadErrorThe current cell could not read a remote cells CSR. The remote cell number is displayed in the data field. These cells will not be able to rendezvous.
1.3.6.1.4.1.11.2.23.35.5361NodehpevtPdCellLateForRendezThe currently executing cell arrived too late to rendezvous with the other cells described in the complex profile as cells it should rendezvous with.
1.3.6.1.4.1.11.2.23.35.5365NodehpevtPdIncompatibleCpuTypesThe currently executing cell detected CPUs that are incompatible with it to be installed on a cell that the current cell is trying to rendezvous with.
1.3.6.1.4.1.11.2.23.35.5366NodehpevtPdCellLateLocalRendezSetThe current cell was too slow creating the local rendezvous set and the other cells have left it behind. It will not be able to participate in the remainder of…
1.3.6.1.4.1.11.2.23.35.5376NodehpevtCellNotInGlobalSetThe reporting cell was not included in the final global set that was agreed upon. This means that another cell either could not reach the reporting cell or the…
1.3.6.1.4.1.11.2.23.35.5380NodehpevtNoViableCoreCellInPdNo cells in the PD can be a core cell. This is fatal.
1.3.6.1.4.1.11.2.23.35.5383NodehpevtErrorPromotingCoreCellSystem Firmware was unable to notify utilities of the selected core cell number.
1.3.6.1.4.1.11.2.23.35.5403NodehpevtFabricNoServiceProvidersThe fabric code is unable to find a service provider for a required banyan service.
1.3.6.1.4.1.11.2.23.35.5404NodehpevtFabricPortErrorThe fabric port specified in the data field had an error.
1.3.6.1.4.1.11.2.23.35.5405NodehpevtFabricReadErrorAn error occurred reading a CSR. The CSR address is displayed in the data field.
1.3.6.1.4.1.11.2.23.35.5406NodehpevtFabricWriteErrorError writing to Fabric. CSR data in data field.
1.3.6.1.4.1.11.2.23.35.5407NodehpevtXbcSlicesHwVersionDifferIncompatible crossbar slices are installed The data field is the two revisions reported by slice1 and slice0 of the CSR data. Bits [31:0] slice0 revision Bits …
1.3.6.1.4.1.11.2.23.35.5408NodehpevtXbcSlicesInDiffLocationCrossbar slices are in different locations. The data field is the two locations reported by slice1 and slice0 of the CSR data.
1.3.6.1.4.1.11.2.23.35.5411NodehpevtMonarchTakeoverA CPU has taken over as the monarch CPU.
1.3.6.1.4.1.11.2.23.35.5416NodehpevtDeadSramSRAM cannot be accessed on the cell board. Execution cannot continue.
1.3.6.1.4.1.11.2.23.35.5417NodehpevtDeadDillonThe PDH Arbiter component/chip cannot be located or used.
1.3.6.1.4.1.11.2.23.35.5418NodehpevtDeadPdhHwA required piece of PDH bus hardware cannot be contacted.
1.3.6.1.4.1.11.2.23.35.5419NodehpevtIoPciBusMixedSpeedsThe physical location of the PCI controller with mixed speeds is displayed in the data field.
1.3.6.1.4.1.11.2.23.35.5420NodehpevtIoPciBusDepthExceededDuring walking of the IO busses, the maximum depth was exceeded. This is a hardware configuration problem. The data field contains the physical location.
1.3.6.1.4.1.11.2.23.35.5432NodehpevtlotimeoutA Timeout occurred during RI initialization. The CSR is in the data field. The alert level will vary.
1.3.6.1.4.1.11.2.23.35.5438NodehpevtIoBuswalkSuperioSuperIO has been detected in the PCI slot displayed in the data field.
1.3.6.1.4.1.11.2.23.35.5440NodehpevtIoSbaCorrDataParityErrIO Link Software error was corrected.
1.3.6.1.4.1.11.2.23.35.5442NodehpevtIoSbaFatalDataParityErrParity error in Reg FIFO Internal parity error.
1.3.6.1.4.1.11.2.23.35.5443NodehpevtIoSbaUncFunctionErrTLB Fetch timeout.
1.3.6.1.4.1.11.2.23.35.5444NodehpevtIoSbaFatalFunctionErrLink presence goes away, FE.
1.3.6.1.4.1.11.2.23.35.5445NodehpevtIoSbaFatalParityErrLBA to SBA parity error on command, rope will go fatal.
1.3.6.1.4.1.11.2.23.35.5446NodehpevtIoSbaFatalMapErrAccess to invalid TLB entry Requesting rope fatal.
1.3.6.1.4.1.11.2.23.35.5447NodehpevtIoSbaFatalTimeoutErrMemory Fetch Timeout.
1.3.6.1.4.1.11.2.23.35.5448NodehpevtIoLbaInitErrAn error was encountered when initing the rope number specified in the data field.
1.3.6.1.4.1.11.2.23.35.5449NodehpevtIoLbaCorrTimeoutErrLBA correctable timeout error was encountered.
1.3.6.1.4.1.11.2.23.35.5450NodehpevtIoLbaUncFunctionErrLBA uncorrectable Function Error was encountered.
1.3.6.1.4.1.11.2.23.35.5451NodehpevtIoLbaUncTimeoutErrLBA uncorrectable Timeout Error was encountered.
1.3.6.1.4.1.11.2.23.35.5452NodehpevtIoLbaMiscUncErrMisc uncorrectable error discovered on LBA.
1.3.6.1.4.1.11.2.23.35.5453NodehpevtIoLbaUncParityErrLBA encountered an uncorrectable parity error.
1.3.6.1.4.1.11.2.23.35.5454NodehpevtIoLbaMiscFatalErrLBA misc. Fatal Error encountered.
1.3.6.1.4.1.11.2.23.35.5455NodehpevtIoLbaFatalFunctionErrLBA Fatal function error encountered.
1.3.6.1.4.1.11.2.23.35.5456NodehpevtIoLbaFatalParityErrLBA Fatal Parity error encountered.
1.3.6.1.4.1.11.2.23.35.5457NodehpevtIoLbaFatalTimeoutErrLBA Fatal timeout error encountered.
1.3.6.1.4.1.11.2.23.35.5458NodehpevtIoDevAdapterMiscUncErrMisc Uncorrectable Error encountered on the card specified in the data field.
1.3.6.1.4.1.11.2.23.35.5459NodehpevtIoDevAdapterMiscFatalErrMisc fatal error was discovered on the PCI card specified in the data field.
1.3.6.1.4.1.11.2.23.35.5464NodehpevtMemDimmSpdExtendedChecksumThe calculated and compared Checksums of the SPD EEPROM don't match.
1.3.6.1.4.1.11.2.23.35.5467NodehpevtOptsHdrCksumErrorThe Options component encountered a header checksum error. The actual data is in the data field of the chassis code.
1.3.6.1.4.1.11.2.23.35.5468NodehpevtOptsDataCksumErrorThe Options service data had a bad checksum. Actual data is in the data field.
1.3.6.1.4.1.11.2.23.35.5473NodehpevtPdMemIntlvWaysMismatchInternal inconsistency in the interleave tables.
1.3.6.1.4.1.11.2.23.35.5474NodehpevtPdMemUnintlvdMemoryThe CellInfoList is not null and was expected to be. There has been an error in interleaving.
1.3.6.1.4.1.11.2.23.35.5478NodehpevtPdMemNoMemoryDescError in constructing the Memory Descriptor.
1.3.6.1.4.1.11.2.23.35.5479NodehpevtPdMemUpdateLocalCellFailedUnable to update the local memory layout.
1.3.6.1.4.1.11.2.23.35.5483NodehpevtPdMemPdtAddrNotFoundA required address was not found within a mapped address in the PDT.
1.3.6.1.4.1.11.2.23.35.5485NodehpevtPdMemPdtInstallFailFailure to install a partition level PDT. Errors prevented it.
1.3.6.1.4.1.11.2.23.35.5490NodehpevtUnusableResourceA critical resource that is required early in the initialization process either could not be found, or was unusable. The specific resource is specified in the …
1.3.6.1.4.1.11.2.23.35.5491NodehpevtFwErrorAn internal firmware error was encountered. This is usually caused by a bad parameter passed to a function, corrupt memory, corrupt malloc tables or something …
1.3.6.1.4.1.11.2.23.35.5492NodehpevtNvramDataCmpErrorNVRAM failed with a data compare error. 3 chassis codes will be sent. The first one will have the expected data and the second the actual data and the third on…
1.3.6.1.4.1.11.2.23.35.5493NodehpevtNvramCrcErrorAn NVRAM CRC Error was detected. There will always be 2 chassis codes sent. The first one will give the expected data and the second the actual data.
1.3.6.1.4.1.11.2.23.35.5494NodehpevtErmGet Error Response Mode has been called. The first 8 bytes of the response mode string are displayed in the data field and must be converted to ASCII from the …
1.3.6.1.4.1.11.2.23.35.5496NodehpevtErrorObtainingSemaphoreThe required semaphore could not be obtained due to errors. The data field contains the IP of the routine trying to obtain the semaphore. A request was placed …
1.3.6.1.4.1.11.2.23.35.5498NodehpevtNvramBlockRevMismatchThe NVRAM block requested has an unexpected revision. This chassis code will be emitted in pairs. The first one will contain the expected revision number, the …
1.3.6.1.4.1.11.2.23.35.5499NodehpevtNvramBlockNotFoundThe requested NVRAM block was not found. The ID that was not found is displayed in the data field.
1.3.6.1.4.1.11.2.23.35.5500NodehpevtNvramBlockLockedThe block id specified in the data field is locked.
1.3.6.1.4.1.11.2.23.35.5501NodehpevtNvramBlockUnlockedFirmware tried to unlock a NVRAM block that was already unlocked. Data field contains the block ID.
1.3.6.1.4.1.11.2.23.35.5502NodehpevtNvramHeaderNotFoundThe header in the NVRAM space was not found.
1.3.6.1.4.1.11.2.23.35.5503NodehpevtNvmFreelistCorruptThe Freelist used vor Non-Volatile Memory allocation is corrpt.
1.3.6.1.4.1.11.2.23.35.5505NodehpevtResetForReconfigSystem firmware has detected a condition that requires the cell to be reset for reconfiguration. The function has been called and is now executing. Data field …
1.3.6.1.4.1.11.2.23.35.5507NodehpevtPdRendezUtilityErrorDuring PD rendezvous, system firmware encountered a problem sending commands to the utilities system. This will prevent a fully functional PD from being create…
1.3.6.1.4.1.11.2.23.35.5509NodehpevtHaltSystem Firmware has determined that cell or system progress must be halted. The data field contains the Instruction Pointer of the function that called for the…
1.3.6.1.4.1.11.2.23.35.5510NodehpevtDuiNoConsoleThe DUI (Developers User Interface) was entered, but there is no console available for the interface.
1.3.6.1.4.1.11.2.23.35.5511NodehpevtErrorProcFailedDuring Error processing and reporting, an error was detected that prevented further processing of errors. The data field contains an ASCII message indicating t…
1.3.6.1.4.1.11.2.23.35.5514NodehpevtReconfigResetFailSystem firmware is unable to complete the request to reset the cell for reconfiguration. Typically, are required step has not been performed yet or a needed re…
1.3.6.1.4.1.11.2.23.35.5515NodehpevtPdErrorReachableSetThe cell was not able to reach all the other cells in its configured set through the fabric. The data field contains the bitmask of actual cells that were reac…
1.3.6.1.4.1.11.2.23.35.5518NodehpevtIoBridgeDepthExceededFirmware detected a PCI-to-PCI bridge that exceeds the maximum supported bridge depth. Firmware will not configure I/O devices below the maximum bridge depth. …
1.3.6.1.4.1.11.2.23.35.5521NodehpevtEfiConsoleDriverErrorDebugging event, not for release. This event is no longer used on Everest/xPeak systems but its event ID is still contained in the code base.
1.3.6.1.4.1.11.2.23.35.5525NodehpevtMemTestCodeInPage0CorruptThis event is unused
1.3.6.1.4.1.11.2.23.35.5527NodehpevtRemoteCellStateUnknownThe reporting cell read an unknown state from a remote cell. This chassis code will be emitted in pairs. The first one indicating the cell number in the data f…
1.3.6.1.4.1.11.2.23.35.5528NodehpevtPdMltplCoreCellsThe reporting Cell thinks that it should be the core cell but has discovered another cell in the same PD that thinks it should be the core cell. This is a seri…
1.3.6.1.4.1.11.2.23.35.5529NodehpevtUtilSendCommandErrorThe utilities system firmware component received an error response from the SINC in response to a command being sent. The exact error is displayed in the data …
1.3.6.1.4.1.11.2.23.35.5530NodehpevtUtilCellSlotErrorSystem Firmware issued the Retrieve Cell Slot State command to the Sync and got an error back. See related chassis code or the specifics of the error.
1.3.6.1.4.1.11.2.23.35.5546NodehpevtMcCellRendezFailedThis denotes the fact that all the cpus in the cell did not rendezvous.
1.3.6.1.4.1.11.2.23.35.5547NodehpevtMcNoAccessToPdThis chassis code indicates that the cell does not have any access to a PD.
1.3.6.1.4.1.11.2.23.35.5548NodehpevtMcLossOfLockstepThis indicates the cell would not be able to join the other cells in the PD level rendezvous. The data portion represents the cell id of the cell that incurred…
1.3.6.1.4.1.11.2.23.35.5550NodehpevtMcPdCellRendezFailedThis indicates that some of the cells did not show up during the PD level rendezvous.
1.3.6.1.4.1.11.2.23.35.5556NodehpevtMcProcErrHaltThis indicates that catastrophic errors have been found in the PIN block of the cell controller. The cell needs to be reset/ halt.
1.3.6.1.4.1.11.2.23.35.5557NodehpevtMcCellMonarchTimeoutThis means that the cell monach cpu has not completed the assigned task within the timeout and hence it will be deconfigured.
1.3.6.1.4.1.11.2.23.35.5558NodehpevtMcPdCellMissedRendezThis indicates that the cell is too late for the PD level rendezvous. And hence it will not join the other PD cells.
1.3.6.1.4.1.11.2.23.35.5559NodehpevtMcPdMonarchTimeoutThis indicates the state where the PD monarch was not able to complete the task within a certain time. It failed.
1.3.6.1.4.1.11.2.23.35.5560NodehpevtRemoteSetViewRootErrorSystem firmware on the Core cell was unable to update a slave cell with the location of the root of the partition tree. The CPU that was unable to be contacted…
1.3.6.1.4.1.11.2.23.35.5566NodehpevtCsrTestFailureRead test on a CSR failed and the CSR contents were not updated. This chassis code will be emitted in 3's, with the CSR Address, expected data, and actual data…
1.3.6.1.4.1.11.2.23.35.5567NodehpevtPdMemGetIcmInfoFailedThis chassis code reports the failure in collecting the ICM parameters needed for the cell interleaving.
1.3.6.1.4.1.11.2.23.35.5568NodehpevtPdMemGetCellInfoFailedThis chassis code indicates that the cell interleaving routine could not get the information on the cell memory.
1.3.6.1.4.1.11.2.23.35.5569NodehpevtPdMemUpdateCellGniFailedThis chassis code is used to represent the failure in updating the GNI information of the cell with the CLM ( cell local memory) information obtained from the …
1.3.6.1.4.1.11.2.23.35.5570NodehpevtPdMemAdjustMinZiFailedThis represents the failure in adjusting the memory information with the minimum ZI requirements.
1.3.6.1.4.1.11.2.23.35.5572NodehpevtStableProfileXsumErrorComplex Profile A (Stable Profile) stored checksum does not match the calculated checksum. The expected data and actual data are displayed in the 2 reporting e…
1.3.6.1.4.1.11.2.23.35.5573NodehpevtDynamicProfileXsumErrorThe Dynamic Complex Profile (Group B) stored checksum did not equal the calculated checksum. The Expected Data and Actual date are displayed in successive chas…
1.3.6.1.4.1.11.2.23.35.5574NodehpevtPartitionProfileXsumErrorThe stored value of the complex profile Group C does not match the calculated value. Expected data and actual data are stored in successive chassis codes.
1.3.6.1.4.1.11.2.23.35.5575NodehpevtStableProfileSeqidInvalidThe Complex Profile Group A sequence ID is invalid. Booting cannot continue. The actual data is in the chassis code data field.
1.3.6.1.4.1.11.2.23.35.5577NodehpevtDynamicProfileSeqidInvalidThe Dynamic Complex Profile (Group B) sequence ID is invalid. The invalid Sequence ID is displayed in the data field.
1.3.6.1.4.1.11.2.23.35.5578NodehpevtPartitionProfileSeqidInvalidThe Group C Partition Complex Profile Sequence ID is invalid. The value read is displayed in the data field.
1.3.6.1.4.1.11.2.23.35.5579NodehpevtEfiFwErrorAn internal EFI firmware error was encountered. This is usually caused by a bad parameter passed to a function, corrupt memory, corrupt malloc, corrupt firmwar…
1.3.6.1.4.1.11.2.23.35.5580NodehpevtCmplxProfilePdNumMismatchThe Complex Profile Group A PD assignment for this cell does not match the PD or Partition number in Group C of the complex profile. This is a fatal condition …
1.3.6.1.4.1.11.2.23.35.5581NodehpevtCmplxProfilePdNumInvalidThe Partition (PD) assigned to this cell in the complex profile group A and C is larger than the maximum allowed number of PDs as specified by Group A.
1.3.6.1.4.1.11.2.23.35.5583NodehpevtXbcPortSm4ErrorTried to obtain the port semaphore but GetPortSemaphore returned an ERROR. Could be a failed write to the port semaphore crossbar CSR or another cell owned the…
1.3.6.1.4.1.11.2.23.35.5584NodehpevtXbcPortSm4NotReleasedCurrently owned the port semaphore but could not release the semaphore. Data field bits 32:63 contain the crossbar ID and bits 0:32 contain the port number.
1.3.6.1.4.1.11.2.23.35.5594NodehpevtBootBmcTokenUploadFailureThere was an error reading from the BMC token when attempting to write to SAL NVM. This is a stop boot condition. Data: Lower 32 bits, BMC Token Number. Upper …
1.3.6.1.4.1.11.2.23.35.5595NodehpevtBootNvmTokenAccessFailureThe read from SAL NVM has failed. This is a stop boot condition. Data: The token number on which the read failed
1.3.6.1.4.1.11.2.23.35.5596NodehpevtBootBmcTokenDownloadErrorThere was an error when trying to write to a BMC Token. This is a boot warning condition. Data: lower 32 bits are BMC token number, upper 32 bits is the status…
1.3.6.1.4.1.11.2.23.35.5597NodehpevtBootErrorWritingFirstBootTokenThere has been an error writing the BMC_FIRST_BOOT token. This is a stop boot condition.
1.3.6.1.4.1.11.2.23.35.5598NodehpevtBootFruReadErrorThe read of a FRU has failed. Data: Device ID of device that failed the FRU read.
1.3.6.1.4.1.11.2.23.35.5599NodehpevtBootFruXsumErrorThe read of a FRU has failed the checksum test. Data: Device ID of device that failed the FRU read.
1.3.6.1.4.1.11.2.23.35.5600NodehpevtBootFruVersionErrorThe read of a FRU has failed due to a version problem. Data: Device ID of device that failed the FRU read.
1.3.6.1.4.1.11.2.23.35.5601NodehpevtBootRomRevToFitRevWarningA ROM Rev and FIT Rev do not match. Data: Code for what didn't match: 0x1 = PAL_A, 0x2 = PAL_B, 0x4 = SAL_A, 0x8 = ACPI, 0xA = EFI
1.3.6.1.4.1.11.2.23.35.5602NodehpevtBootRomRevToRevBlockWarningA ROM Rev and Rev Block do not match. Data: Code for what didn't match: 0x3 = PAL, 0x5 = SAL_A, 0x7 = SAL_B, 0x9 = ACPI, 0xB = EFI, 0xC = BMC
1.3.6.1.4.1.11.2.23.35.5603NodehpevtBootPrimaryFitBadThe FIT is bad.
1.3.6.1.4.1.11.2.23.35.5604NodehpevtBootSecondaryFitBadThe FIT is bad.
1.3.6.1.4.1.11.2.23.35.5605NodehpevtBootPalARomWarningPAL_A_ROM has generated a warning.
1.3.6.1.4.1.11.2.23.35.5606NodehpevtBootPalBRomWarningPAL_B_ROM has generated a warning.
1.3.6.1.4.1.11.2.23.35.5607NodehpevtErrorUpdatingGroupBProfileFirmware tried to default the Dynamic (Group B) complex profile and encountered an error.
1.3.6.1.4.1.11.2.23.35.5617NodehpevtIoPciPerrAn I/O device (or host bridge) detected a bus parity error. An I/O device (or host bridge) mastered a bus transaction and received a parity error response from…
1.3.6.1.4.1.11.2.23.35.5618NodehpevtIoPciSerrAn I/O device (or host bridge) detected an internal error. An I/O device (or host bridge) detected a bus error. Data Field: Physical location of the I/O device…
1.3.6.1.4.1.11.2.23.35.5619NodehpevtIoCheckLbaDeconfigErrFirmware has deconfigured an I/O host bridge due to an error (see earlier error event). Firmware will display the following EFI warning message, 'Failed I/O sl…
1.3.6.1.4.1.11.2.23.35.5621NodehpevtErrorUpdatingGroupCProfileFirmware tried to default the Partition (Group C) complex profile and encountered an error.
1.3.6.1.4.1.11.2.23.35.5622NodehpevtCellNotInAPdThe Reporting Cell is not configured to be in a PD, according to Complex Profile Group A.
1.3.6.1.4.1.11.2.23.35.5623NodehpevtMemDimmThermalLoadOrderWarnDIMMs are not loaded on the extender in a thermally optimal way. Boot is still possible, but the DIMM arrangement should be changed to the loading order recomm…
1.3.6.1.4.1.11.2.23.35.5626NodehpevtCellMajorityNotPresentNot enough cells made the Rendezvous for boot to continue. The rules are listed in the cause action section.
1.3.6.1.4.1.11.2.23.35.5638NodehpevtInitRendezvousSlavesFailSFW's INIT handler failed to rendezvous the processors.
1.3.6.1.4.1.11.2.23.35.5646NodehpevtMcIoClearFailSFW's Machine Check Handler was unable to log or clear I/O error registers.
1.3.6.1.4.1.11.2.23.35.5655NodehpevtMcPalCantEscalateToBerrCannot escalate an MCA to BERR
1.3.6.1.4.1.11.2.23.35.5656NodehpevtMcPalCantEscalateToBinitCannot escalate an MCA to BINIT.
1.3.6.1.4.1.11.2.23.35.5657NodehpevtMcPalGetFeatFailSFW failed to get the feature set from PAL.
1.3.6.1.4.1.11.2.23.35.5658NodehpevtMcPalRendFailPAL Failed to rendezvous the processors during a MCA.
1.3.6.1.4.1.11.2.23.35.5659NodehpevtMcPalSetFeatFailSFW failed to get the feature set from PAL.
1.3.6.1.4.1.11.2.23.35.5677NodehpevtMcRendezvousSlavesFailSFW's MCA Handler has failed to rendezvous all the slaves Data: Return from the rendezvous call.
1.3.6.1.4.1.11.2.23.35.5679NodehpevtMcRendezBadVectRangeA bad rendezvous vector has been registered.
1.3.6.1.4.1.11.2.23.35.5682NodehpevtMcRendezNoMonarchNo Machine Check Monarch exists, exiting MC Rendezvous.
1.3.6.1.4.1.11.2.23.35.5683NodehpevtMcRendezNoWakeupThe OS has not registered a wake-up mechanism for rendezvous.
1.3.6.1.4.1.11.2.23.35.5684NodehpevtMcRendezPalCantEscalatePAL call failed to set the BINIT escalation bit
1.3.6.1.4.1.11.2.23.35.5685NodehpevtMcRendezPalGetFeatFailThe PAL call PAL_GET_FEATURES has failed.
1.3.6.1.4.1.11.2.23.35.5686NodehpevtMcRendezPalSetFeatFailThe PAL call PAL_SET_FEATURES has failed.
1.3.6.1.4.1.11.2.23.35.5692NodehpevtSalAbiFwErrorAn internal SAL_ABI firmware error was encountered. This is usually caused by a bad parameter passed to a function, corrupt memory, corrupt malloc, corrupt fir…
1.3.6.1.4.1.11.2.23.35.5696NodehpevtMemExtLoadOrdErrThe Memory extenders have not been loaded in the correct order.
1.3.6.1.4.1.11.2.23.35.5698NodehpevtEfiEsiTableLengthErrThe length field within the ESI (Extensible SAL Interface) table does not agree with the product of the entry_count field and the size of each entry. Data Fiel…
1.3.6.1.4.1.11.2.23.35.5700NodehpevtEfiEsiTableChecksumErrThe computed checksum for the ESI (Extensible SAL Interface) table is not zero as expected. EFI is halting. Data Field: the computed checksum.
1.3.6.1.4.1.11.2.23.35.5701NodehpevtEfiEsiTableUnsupportedEntryTypeEFI found an unsupported entry type within the ESI (Extensible SAL Interface) Table. Data Field: unknown type.
1.3.6.1.4.1.11.2.23.35.5704NodehpevtEfiGuidTooLargeEFI was attempting to output a GUID in the EFI_GUID_HALF1 and EFI_GUID_HALF2 events which was larger than 128 bits. The data field contains the actual length o…
1.3.6.1.4.1.11.2.23.35.5708NodehpevtEfiHaltEFI is halting. Look for the cause of the halt in preceding events. Data Field: the 'halt' (0x0F) major change in system state code.
1.3.6.1.4.1.11.2.23.35.5711NodehpevtMemChipspareNotSupportedThis code will be sent when FW detects a rank installed in the system that doesn't support chipspare. The data field is used to indicate the rank that the x8 D…
1.3.6.1.4.1.11.2.23.35.5712NodehpevtEfiAssertErrorEFI has detected an internal error. The actual error is unspecified by this event. Examine previous events and console output for possible explanations.
1.3.6.1.4.1.11.2.23.35.5713NodehpevtEfiEfiBreakpointEFI has executed the 'break' shell command. EFI is halting. The 'break' command is currently implemented as an infinite loop to halt EFI.
1.3.6.1.4.1.11.2.23.35.5714NodehpevtEfiHcdHostHungThe EFI USB interrupt service has detected the host controller is hung. EFI is halting.
1.3.6.1.4.1.11.2.23.35.5715NodehpevtEfiSalHandoffVerMismatchThe EFI/SAL handoff structure's version does not match EFI expectations. EFI is halting. Look for EFI_SAL_HANDOFF_VER_EXPECTED to provide EFI's expected value.…
1.3.6.1.4.1.11.2.23.35.5717NodehpevtEfiSalRtcServiceNotInitEFI is unable to obtain access to all the RTC (Real Time Clock) SAL services. This means that EFI is unable to fully interact with the RTC. EFI is halting. Dat…
1.3.6.1.4.1.11.2.23.35.5718NodehpevtEfiSalTimerServiceNotInitEFI is unable to obtain access to all the SAL timer services. This means that EFI is unable to fully interact with the timer. EFI is halting. Data Field: Retur…
1.3.6.1.4.1.11.2.23.35.5719NodehpevtEfiSalStarttimerServiceNotInitEFI is unable to start the periodic timer. This timer interrupts EFI periodically to process time sensitive events. EFI is halting. Data Field: Return status f…
1.3.6.1.4.1.11.2.23.35.5720NodehpevtEfiNoIoPortSpaceRegionFoundEFI did not find an I/O port space region in the MDT. EFI is halting.
1.3.6.1.4.1.11.2.23.35.5721NodehpevtEfiBreakpointEFI reached an unimplemented section of code. EFI is halting. Data Field: Unique identifier indicating the location reached within the code.
1.3.6.1.4.1.11.2.23.35.5722NodehpevtEfiSpeedyBootTokenNotReadEFI was unable to read the current speedy boot settings. The speedy boot settings are stored within the BMC. EFI will use a default value of 0 and continue boo…
1.3.6.1.4.1.11.2.23.35.5723NodehpevtEfiSalCallbackAttemptedA SAL Callback was attempted. This is not permitted. EFI is halting. Data Field: index of the function that was being called.
1.3.6.1.4.1.11.2.23.35.5724NodehpevtEfiSalFreqBaseUnknownWhile attempting to calibrate the EFI stall timer, system firmware is unable to determine the frequency of the CPU interval timer. System firmware will assume …
1.3.6.1.4.1.11.2.23.35.5725NodehpevtEfiSysEventAlreadyInitThe EFI system events have already been initialized. This is unexpected. EFI is continuing. Data Field: the current value of the system event entry point.
1.3.6.1.4.1.11.2.23.35.5726NodehpevtEfiSysEventCreateEventFailEFI was unable to create an internal virtualization event while initializing EFI's System Events (IPMI events). This internal event is not an IPMI event; rathe…
1.3.6.1.4.1.11.2.23.35.5728NodehpevtFpgaNodeInitErrorAn error was detected while initializing the FPGA node and services associated with the PDH.
1.3.6.1.4.1.11.2.23.35.5729NodehpevtIoconfigNodeInitErrorFirmware encountered an error when creating the ioconfig node as a child of the pdh node.
1.3.6.1.4.1.11.2.23.35.5730NodehpevtDillonPdhNodeInitErrorSystem firmware was unable to correctly set up the pdh arbiter node as a child of the pdh node, or was unable to locate and attach the pdh arbiter service to t…
1.3.6.1.4.1.11.2.23.35.5731NodehpevtPdhPropertyErrorThe PDH service was unable to either get or set the property specified in the data field as an ASCII message.
1.3.6.1.4.1.11.2.23.35.5732NodehpevtPdhAcpihwNodeErrorPDH encountered an error creating the ACPI Hardware Node in the device tree or installing its properties.
1.3.6.1.4.1.11.2.23.35.5733NodehpevtPdhIpmiNodeErrorThe PDH service encountered an error while creating the ipmi node or adding properties to it. The status is in the data field.
1.3.6.1.4.1.11.2.23.35.5734NodehpevtBootCpusNotCompatibleInstalled processors are not of compatible models or families
1.3.6.1.4.1.11.2.23.35.5735NodehpevtBootCacheSizesInconsistantProcessors with different cache sizes are installed
1.3.6.1.4.1.11.2.23.35.5737NodehpevtBootSelectingNewMonarchSFW is selecting a new monarch processor due to compatibility problems.
1.3.6.1.4.1.11.2.23.35.5738NodehpevtBootMonSelSteppingsNoEqualThe monarch stepping is not equal to the lowest installed CPU stepping.
1.3.6.1.4.1.11.2.23.35.5740NodehpevtBootCpuOverClockedA CPU's FSB frequency is overclocked. Data: Local CPU Number.
1.3.6.1.4.1.11.2.23.35.5741NodehpevtBootCpuInfoRomAccessErrorThere was an error reading the info ROM area of the CPU. Data: CPU Physical location
1.3.6.1.4.1.11.2.23.35.5742NodehpevtBootPalANotExecutedPAL_A has not been executed and control has been transferred back to SAL_B.
1.3.6.1.4.1.11.2.23.35.5743NodehpevtBootPalBNotExecutedPAL_B has not been executed and control has been transferred back to SAL_B.
1.3.6.1.4.1.11.2.23.35.5744NodehpevtBootProtoTypeCpuInstalledData: Lower 32 bits have Local CPU Number
1.3.6.1.4.1.11.2.23.35.5745NodehpevtBootFinalRendezWatchdogFailData: Monarch's Local CPU Number
1.3.6.1.4.1.11.2.23.35.5746NodehpevtCpuSupplementalTestFailedSupplemental tests have been run on the cpus in the node and an error was encountered. If this event id is only emitted once, then the cpu detected that it fai…
1.3.6.1.4.1.11.2.23.35.5747NodehpevtFabricReadMbeErrorWhile reading a XBC CSR, a multi-bit error was found. Data field includes the CSR data that includes the error. A previous event, FABRIC_READ_ERROR, details th…
1.3.6.1.4.1.11.2.23.35.5749NodehpevtFabricUnexpectedStatusThe return value from a function was an unknown value. Data field is the unknown status that was returned.
1.3.6.1.4.1.11.2.23.35.5750NodehpevtEfiSysidBmcWarningEFI queries the BMC on the system board for the status of a system ID. The BMC could not complete the request successfully or on time. Data Field: Internal EFI…
1.3.6.1.4.1.11.2.23.35.5751NodehpevtEfiSysidBmcReadErrorBMC reported a system ID status as inaccessible, reported invalid status or cannot return the current value of a system ID. Data Field: uuid status or internal…
1.3.6.1.4.1.11.2.23.35.5752NodehpevtEfiSysidBmcWriteErrorFirmware tried to write a primary or secondary system ID as requested by the user during the boot sequence. The write failed. Data Field: Internal EFI function…
1.3.6.1.4.1.11.2.23.35.5753NodehpevtEfiSysidInvalidThe system ID(s) currently in the system is either invalid or, if the EFI_SYSID_BMC_WARNING, EFI_SYSID_BMC_READ_ERROR or EFI_SYSID_BMC_WRITE_ERROR events are a…
1.3.6.1.4.1.11.2.23.35.5755NodehpevtEfiRtIvtEsiTableErrEFI is unable to find the SAL services for installing interrupt handlers. EFI was trying to install the run-time handlers that are required for normal EFI boot…
1.3.6.1.4.1.11.2.23.35.5756NodehpevtEfiRtIvtEsiQueryErrEFI is unable to find the SAL service to install run-time interrupt handlers. These handlers are required for normal EFI booting. EFI will be halting. Data Fie…
1.3.6.1.4.1.11.2.23.35.5757NodehpevtEfiBootIvtEsiTableErrEFI is unable to find the SAL services for installing interrupt handlers. EFI was trying to install the boot-time handlers that are required for normal EFI boo…
1.3.6.1.4.1.11.2.23.35.5758NodehpevtEfiBootIvtEsiQueryErrEFI is unable to find the SAL service to install boot-time interrupt handlers. These handlers are required for normal EFI booting. EFI will be halting. Data Fi…
1.3.6.1.4.1.11.2.23.35.5760NodehpevtUtilitiesParmListTooLargeToo many parameters were passed in a request for the utilities system to perform an operation. No more data is provided.
1.3.6.1.4.1.11.2.23.35.5762NodehpevtXbcPortPresenceErrorA crossbar port is expected to be present, but its presence detect bit is not set. Data field bits 32:43 contain the crossbar ID, bits 44:55 contain the port n…
1.3.6.1.4.1.11.2.23.35.5763NodehpevtXbcPortHwLinkErrorA crossbar port is expected to have its HW_LINK_OK bit set, but it is not. Data field bits 32:43 contain the crossbar ID, bits 44:55 contain the port number fo…
1.3.6.1.4.1.11.2.23.35.5764NodehpevtXbcPortFeErrorA connected crossbar port was found to have its FE bit set. Data field bits 32:43 contain the crossbar ID, bits 44:55 contain the port number for which the err…
1.3.6.1.4.1.11.2.23.35.5766NodehpevtXinLinkInitErrorThere was an error while initializing the Cell Controller-Xbc interface. The data field contains the address of the Cell Controller CSR for which the error occ…
1.3.6.1.4.1.11.2.23.35.5767NodehpevtXinLinkInitFailedThe CC - XBC link failed to initialize.
1.3.6.1.4.1.11.2.23.35.5768NodehpevtEfiGetMfgModeNotInitEFI is unable to determine current system mode. The EFI/SAL interface is not initialized. This interface should have been initialized before now. This event in…
1.3.6.1.4.1.11.2.23.35.5769NodehpevtEfiBmcMfgModeInvalidThe BMC has returned an invalid system mode. Data Field: the invalid mode. Expected values are 0 or 1.
1.3.6.1.4.1.11.2.23.35.5770NodehpevtEfiEnterMfgModeNotInitEFI is unable to specify a new system mode. The EFI/SAL interface point is not initialized. This interface should have been initialized before now. This event …
1.3.6.1.4.1.11.2.23.35.5771NodehpevtEfiExitMfgModeNotInitEFI is unable to enter normal system mode. The EFI/SAL interface is not initialized. This interface should have been initialized before now. This event indicat…
1.3.6.1.4.1.11.2.23.35.5772NodehpevtEfiTaccessServiceNotInitEFI is unable to initialize part of the SAL/EFI interface. This crucial service provides access to certain BMC functionality such as the security system. EFI w…
1.3.6.1.4.1.11.2.23.35.5774NodehpevtTreeNodeNotFoundA needed tree node was not found. The data field contains the ASCII name of the tree node that was not found.
1.3.6.1.4.1.11.2.23.35.5776NodehpevtEfiSystemStateRunningErrEFI is unable to modify the system state from 'booting' to 'running'. This is done as part of Exit Boot Services. The system will not be able to enter a sleep …
1.3.6.1.4.1.11.2.23.35.5777NodehpevtPalBusConfigIncompatibleCPUBusConfigValue setting in options as been compared with what is reported by PAL as settable and CPUBusConfigValue is specifying at least one bit that is not…
1.3.6.1.4.1.11.2.23.35.5778NodehpevtPalGetBusFeaturesFailedFirmware was unable to correctly issue the Get Processor Bus Dependent Configuration Features command.
1.3.6.1.4.1.11.2.23.35.5779NodehpevtMemDimmPairMismatchA pair of DIMMs installed in the system are mismatched, and that pair of DIMMs will not be used. The data field indicates which pair of DIMMs are mismatched in…
1.3.6.1.4.1.11.2.23.35.5784NodehpevtEfiPosseLibNotInitEFI is unable to initialize internal library. This collection of internal services is required for much of EFI's functionality. EFI is halting.
1.3.6.1.4.1.11.2.23.35.5785NodehpevtEfiSecurityNotInitEFI is unable to initialize the security level. The privilege level of the system may or may not be Admin. It is likely certain EFI facilities will be unavaila…
1.3.6.1.4.1.11.2.23.35.5786NodehpevtEfiSecInvalidSysmodeEFI detected an invalid value for its internal privilege level. This value is stored within SAL. EFI will continue but system security may be compromised. Data…
1.3.6.1.4.1.11.2.23.35.5787NodehpevtEfiSecSetPassLevelErrEFI detected an invalid privilege level when setting a BMC password. Only the levels of Admin (0x30) and User (0x20) are permitted. Data Field: the invalid pri…
1.3.6.1.4.1.11.2.23.35.5788NodehpevtMdtBadSFW has determined that the Memory Data Table (MDT) table is invalid.
1.3.6.1.4.1.11.2.23.35.5790NodehpevtBootCpuBadCoreFixedRatioProcessor has incompatible fixed core ratio. Data: Local CPU Number.
1.3.6.1.4.1.11.2.23.35.5791NodehpevtBootAllCpusSlatedForCompatDeconfigData: A bitmask for which CPUs are slated to be deconfigured
1.3.6.1.4.1.11.2.23.35.5793NodehpevtXbcReadRemoteRouteErrorAn error occurred while reading a crossbar remote route table, or an unexpected/invalid value was read from the table. The data field consists of the crossbar …
1.3.6.1.4.1.11.2.23.35.5794NodehpevtXbcReadNeighborInfoErrorAn error occurred while trying to read the PORT[n]_NEIGHBOR_INFO crossbar CSR. The data field consists of the crossbar ID (32:43) and port number (44:55) for w…
1.3.6.1.4.1.11.2.23.35.5795NodehpevtMemDimmQuadMismatchA quad of DIMMs installed in the system are mismatched, and that quad of DIMMs will not be used. The data field indicates which quad of DIMMs are mismatched in…
1.3.6.1.4.1.11.2.23.35.5796NodehpevtMemDimmFailedThe DIMM at the physical location given by the data field had excessive errors and has been marked as 'FAILED' by firmware.
1.3.6.1.4.1.11.2.23.35.5797NodehpevtXbcPortOeErrorA XBC port was expected to be functional, but its OE bit was not set. The data field consists of the contents of the port_status CSR (0:31), the XBC number (32…
1.3.6.1.4.1.11.2.23.35.5798NodehpevtXbcPortStatusErrorUnable to read the PORT_STATUS CSR for a XBC port. The data field consists of the contents of the PORT_STATUS CSR (0:31), the XBC number (32:43), and the port …
1.3.6.1.4.1.11.2.23.35.5799NodehpevtXbcPortLandminedA XBC port was unexpectedly found to be landmined. The data field consists of the XBC number (32:43) and the port number (44:55).
1.3.6.1.4.1.11.2.23.35.5800NodehpevtPdIncompatibleCpuSpeedsReporting cell tried to rendezvous with a cell with processors that are running at a different speed. The data field lists the offending cell
1.3.6.1.4.1.11.2.23.35.5802NodehpevtFabricCellLinkNotInitThe link between the local CC and the local XBC is unexpectedly not initialized. The data field is the XIN_LINK_STATE CC CSR value.
1.3.6.1.4.1.11.2.23.35.5803NodehpevtFabricInvalidXbcNumA value that was expected to be a XBC number was found to be an invalid XBC number. The data field is the invalid XBC number.
1.3.6.1.4.1.11.2.23.35.5804NodehpevtFabricInvalidXbcPortNumA value that was expected to be a valid XBC port number was found to be invalid. The data field is the XBC number (33:44) and the invalid XBC port number (44:5…
1.3.6.1.4.1.11.2.23.35.5805NodehpevtUtilitiesLedParamErrorA bad parameter was passed to the utilities function that manipulates the LED on replaceable parts. The offending parameter is displayed in the data field.
1.3.6.1.4.1.11.2.23.35.5806NodehpevtFabricUnexpectedNtypeA neighbor type read from a XBC PORT_NEIGHBOR_INFO CSR was different than the expected neighbor type. This event is emitted twice, first with expected data and…
1.3.6.1.4.1.11.2.23.35.5807NodehpevtFabricPortNotCcA XBC port number was unexpectedly found to not be a valid XBC-CC port. The data field consists of the XBC number (32:43) and the port number (44:55).
1.3.6.1.4.1.11.2.23.35.5808NodehpevtFabricPortNotXbcA XBC port was unexpectedly found to be an invalid XBC-XBC port. The data field consists of the XBC number (32:43) and the port number (44:55).
1.3.6.1.4.1.11.2.23.35.5809NodehpevtFabricUnexpectedNChipThe XBC neighbor chip number does not match the expected value for this topology. The data field contains the expected neighbor chip number (32:63) and the act…
1.3.6.1.4.1.11.2.23.35.5810NodehpevtFabricUnexpectedNPortThe XBC neighbor port number does not match the expected value for this topology. The data field contains the expected neighbor port number (32:63) and the act…
1.3.6.1.4.1.11.2.23.35.5811NodehpevtBootNvmWriteToBmcTokenFailureA write to a BMC token has failed. This is a boot warning condition. Data: Upper 32 bits, BMC failure return code. Lower 32 bits, BMC token number that failed.
1.3.6.1.4.1.11.2.23.35.5812NodehpevtUtilitiesLedErrorThe utilities system reported an error while trying to carry out the command to turn on, flash or turn off the LED. The status returned by the command is displ…
1.3.6.1.4.1.11.2.23.35.5813NodehpevtDuplicateCpuIds2 cpus think that they have the same ID within the cell. Typically this would mean that PAL reported the same cpu id for more than 1 cpu on a bus. The cpuid is…
1.3.6.1.4.1.11.2.23.35.5823NodehpevtHp-uxCrashdumpStartedOS crashdump started (D700)
1.3.6.1.4.1.11.2.23.35.5824NodehpevtHp-uxHexFaultCodeOS legacy PA hex fault code (Bxxx). Possible I/O error or system panic
1.3.6.1.4.1.11.2.23.35.5825NodehpevtHp-uxDumpStatusA memory dump occurred on the system, or on one partition in a cellular system. The dump occurred due to either a non-recoverable error or by user request. EFx…
1.3.6.1.4.1.11.2.23.35.5827NodehpevtSettingProcTimeoutFailSFW has failed to set the processor timeout value via a PAL call. Data: PAL call return value.
1.3.6.1.4.1.11.2.23.35.5832NodehpevtEfiSecInitVerifyErrDuring EFI security initialization, the attempt to determine what privilege level a blank password provides, failed. Most likely this indicates the BMC has fai…
1.3.6.1.4.1.11.2.23.35.5833NodehpevtEfiSecInitCloseErrAs part of normal security initialization, EFI attempted to issue a close session to the BMC (I.e. force the BMC to GUEST mode). This attempt failed. EFI is un…
1.3.6.1.4.1.11.2.23.35.5834NodehpevtEfiSecInitOpenErrAs part of normal security initialization, EFI attempted to issue an open session to the BMC in order to raise the privilege level to the highest permitted by …
1.3.6.1.4.1.11.2.23.35.5836NodehpevtEfiSecInitWriteErrAs part of normal security initialization, EFI attempted to record the current privilege level. This attempt failed. EFI is unable to initialize the security s…
1.3.6.1.4.1.11.2.23.35.5837NodehpevtEfiSecInitWriteDeniedAs part of normal security initialization, EFI attempted to record the current privilege level. This attempt failed with a privilege violation error. EFI is un…
1.3.6.1.4.1.11.2.23.35.5853NodehpevtHp-uxDumpWriteErrorOS dump, error writing image area to disk (E055)
1.3.6.1.4.1.11.2.23.35.5896NodehpevtErrDeadlockResetDetectedEarly in bootstrap, the coherency controller (CC) registers are checked for Deadlock Recovery Reset. This chassis code indicates that CC logs will be stored to…
1.3.6.1.4.1.11.2.23.35.6002NodehpevtMemParityErrSFW detected a memory address parity error. The data field contains the physical location of DIMM that saw the parity error.
1.3.6.1.4.1.11.2.23.35.6074NodehpevtMemDimmLoadOrdErrThe loading order of the DIMMs is incorrect. The cell is halted.
1.3.6.1.4.1.11.2.23.35.6146NodehpevtMemRefreshStartErrorTimeout Waiting for SDRAM parts to become ready - mem_status[0] Refresh Control Register
1.3.6.1.4.1.11.2.23.35.6180NodehpevtMemExtBaseboardIncompatibleThe version of Memory extender installed in the system has not been qualified to work with the version of the baseboard installed in the system.
1.3.6.1.4.1.11.2.23.35.6730NodehpevtFabricDifferentTopologiesThere is a fabric topology mismatch with the XBCs in the complex. Data Field: (Topology of XBC << 32) | Topology of destination XBC 0x00 Topology not yet deter…
1.3.6.1.4.1.11.2.23.35.6795NodehpevtFabricInvalidXbc2XbcPortWhile routing the XBC to XBC ports, an invalid port was encountered. The data field is the crossbar number (32:43) and the port number (44:55).
1.3.6.1.4.1.11.2.23.35.7652NodehpevtFabricGetNeighborInfoErrorThe XBC could not get neighbor information. Data Field: XBC # << 32 | internal port attempting to access neighbor
1.3.6.1.4.1.11.2.23.35.7653NodehpevtXbcRoutingErrorStateFor the XBC being routed, routing has already been attempted, but an error occurred. Inspect chassis codes from other cells for more details regarding the natu…
1.3.6.1.4.1.11.2.23.35.7655NodehpevtNoNvmErrLogSpaceThis means that the error event log cannot be logged to the persistent storage. The data field gives the event type that was supposed to be logged.
1.3.6.1.4.1.11.2.23.35.7657NodehpevtXbcPortErrorAn XBC port was found to have an unexpected error. The data field consists of the crossbar number (32:63) and the current port errors (0:31)
1.3.6.1.4.1.11.2.23.35.7658NodehpevtXbcPortRouteAroundDuring fabric routing a port on a XBC was found in error or had been previously marked as in error. PDC will route around this XBC port. Data Field: XBC number…
1.3.6.1.4.1.11.2.23.35.7660NodehpevtXbcUnexpectedStateData field: the unexpected forward progress state (0:31) XBC number (32:44) Cell number (56:63)
1.3.6.1.4.1.11.2.23.35.7661NodehpevtXbcRoutingStateTimeoutA crossbar was found to be in an unexpected forward progress state during fabric routing. This crossbar stayed in the unexpected state until Fabric Discovery t…
1.3.6.1.4.1.11.2.23.35.7663NodehpevtXbcNeighborPortNotRoutableAn XBC port was found that is not healthy. This indicates at least one of the following about the port: - Hardware link is not okay - Presence detect is false …
1.3.6.1.4.1.11.2.23.35.7664NodehpevtFabricCcToXbcErrorThe CC to XBC link is not viable.
1.3.6.1.4.1.11.2.23.35.7666NodehpevtFabricRouteXbcErrorThere was a problem performing remote routing on the local XBC. Chassis codes sent before this one may provide more details about the exact nature of the probl…
1.3.6.1.4.1.11.2.23.35.7667NodehpevtFabricMaxBrokenLinksTwo or more XBC-XBC links were found to be broken. The data field is the XBC number (32:63) and a bit map of the ports broken (0:31)
1.3.6.1.4.1.11.2.23.35.7669NodehpevtXbcSemaphoreTakeoverFailedAfter unlocking the XBC Global Semaphore for a takeover, this cell did not get the semaphore.
1.3.6.1.4.1.11.2.23.35.7671NodehpevtXbcForceUnlockSm4TimeoutWhen a cell holds an XBC semaphore for an extended period of time, fabric will attempt to takeover the semaphore so that the rest of the cells will have access…
1.3.6.1.4.1.11.2.23.35.7673NodehpevtXbcGetGlobalSm4TimeoutDuring Fabric Discovery, the cell will wait until it gets the XBC's Global Semaphore. It waits for a very long time. This chassis code indicates that the wait …
1.3.6.1.4.1.11.2.23.35.7674NodehpevtXbcReleaseSm4TimeoutThe XBC Release Semaphore timeout is designed to fail last. The semaphore could not be released. Any other cell (even outside the PD) may be blocked because th…
1.3.6.1.4.1.11.2.23.35.7684NodehpevtMpBatteryFailureManagement Processor Firmware detected improper data in NVRAM (bad checksums.) Either the NVRAM layout changed, or the Management Processor Battery may not be …
1.3.6.1.4.1.11.2.23.35.7685NodehpevtMpSoftwareErrorManagement Processor Firmware detected a software error and is logging an event. The data represents data associated with the error seen.
1.3.6.1.4.1.11.2.23.35.7686NodehpevtMpI2cCommErrorAn I2C Communication failure with the Baseboard Management Controller was detected. Without I2C communication, the system cannot be powered on/off or reset.
1.3.6.1.4.1.11.2.23.35.7690NodehpevtRomCrcErrorA stored CRC value did not match the calculated CRC value for the specified address.
1.3.6.1.4.1.11.2.23.35.7718NodehpevtIoIdentifyIoBpFailedSee Summary.
1.3.6.1.4.1.11.2.23.35.7732NodehpevtCpuRevisionMismatch2 cpus in the system are reporting different revisions. This event will be emitted in groups of 3 with the two revisions reported in the first 2 data fields an…
1.3.6.1.4.1.11.2.23.35.7733NodehpevtCpuFreqMismatchThis chassis code will be emitted in pairs. 2 cpus are reporting that they are running at different frequencies. The two frequencies are reported in the data f…
1.3.6.1.4.1.11.2.23.35.7734NodehpevtCpuOverclockedThe rating for the cpu and the actual speed will be emitted in 2 sequential event data fields.
1.3.6.1.4.1.11.2.23.35.7758NodehpevtCmplxProfilIncoherentThe complex profile is stored in NVRAM on the MP and each cell. All copies must match. For this error to be generated, not only is the MP's copy of the complex…
1.3.6.1.4.1.11.2.23.35.7760NodehpevtDuplicateCabinetThe MP detected 2 or more cabinets with the same cabinet number.
1.3.6.1.4.1.11.2.23.35.7767NodehpevtIdCommandRequiredThe complex identification information in group A of the complex profile is invalid. The MP (Manageability Processor) command 'ID' must be run. The SSKEY hardw…
1.3.6.1.4.1.11.2.23.35.7771NodehpevtNvramBatteryFailThe battery on the SBCH is below the safe threshold. The battery can be replaced online.
1.3.6.1.4.1.11.2.23.35.7773NodehpevtPartitionTimeoutResetThe partition is being reset because its watchdog timer expired and automatic restart is enabled.
1.3.6.1.4.1.11.2.23.35.7774NodehpevtPdhcWatchdogTimedOutThe processor dependent hardware controller (PDHC) on the cell board had its watchdog timer expire. The PDHC will reset the watchdog as the main program runs. …
1.3.6.1.4.1.11.2.23.35.7781NodehpevtAbortPowerupOthThe Cabinet Power Up request was aborted due to ambient air over temperature.
1.3.6.1.4.1.11.2.23.35.7782NodehpevtAbortPwrupBpsThe power requirements for the cabinet exceeds the capabilities of the available Bulk Power Supplies. The PM3 section of the Utilities Subsystems keeps a tally…
1.3.6.1.4.1.11.2.23.35.7783NodehpevtAbortStartBlowrWhen given a power up request, the cabinet had to abort the start up due to less than the required number of Cabinet Blowers installed.
1.3.6.1.4.1.11.2.23.35.7784NodehpevtAbortStartIofanWhen given a power up request, the cabinet had to abort the start up due to less than the required number of IO fans present.
1.3.6.1.4.1.11.2.23.35.7786NodehpevtAcDeletedThe AC power connected to the PDCA (Power Distribution Control Assembly) was removed. The data field contains the physical location of the PDCA. The PDCA sourc…
1.3.6.1.4.1.11.2.23.35.7791NodehpevtBlowrFailA cabinet main blower has failed. Depending on the number of blowers still operating, the cabinet may or may not shut down. View the Error Log entries to deter…
1.3.6.1.4.1.11.2.23.35.7793NodehpevtBpsFail48fltA 48 Volt DC Converter powered by the specified PDCA failed on the designated Bulk Power Supply. The PDCA powering the converter on the BPS that failed can be …
1.3.6.1.4.1.11.2.23.35.7795NodehpevtBpsFailFanfltThe designated Bulk Power Supply is reporting its fan has failed.
1.3.6.1.4.1.11.2.23.35.7796NodehpevtBpsFailOtThe 48 Volt DC Converter powered by the specified PDCA in the designated Bulk Power Supply, is in over temp condition. The PDCA powering the converter on the B…
1.3.6.1.4.1.11.2.23.35.7798NodehpevtBpsNotRedundantThe number of functioning Bulk Power Supplies has decreased to where the Cabinet Power supplied (number of available Bulk Power Supplies times power output per…
1.3.6.1.4.1.11.2.23.35.7799NodehpevtBpsOvervoltageThe PM has detected the value of +48V power, as measured on the UGUY board, has exceeded an upper threshold.
1.3.6.1.4.1.11.2.23.35.7803NodehpevtBpsUndervoltageThe PM has detected the value of +48V power, as measured on the UGUY board, has fallen below a lower threshold.
1.3.6.1.4.1.11.2.23.35.7806NodehpevtCabFanFailA cabinet fan has failed. Depending on the number of cabinet fans still operating, the cabinet may or may not shut down. View the Error Log entries to determin…
1.3.6.1.4.1.11.2.23.35.7822NodehpevtHkpOvervoltageHousekeeping power has exceeded expected levels.
1.3.6.1.4.1.11.2.23.35.7823NodehpevtHkpUndervoltageHousekeeping power has fallen below expected levels.
1.3.6.1.4.1.11.2.23.35.7824NodehpevtIllegalBpsCfgOrPhaseFltThrough failures or reconfiguration, the BPS for the cabinet named are illegally configured. There must be a BPS connected to each phase of the power. Phase 1 …
1.3.6.1.4.1.11.2.23.35.7825NodehpevtIllegalBpsidA Bulk Power Supply is reporting an unknown BPS ID. The Bulk Power Supply will not be powered up and added to the Power Available tally. If cabinet is not powe…
1.3.6.1.4.1.11.2.23.35.7827NodehpevtInletOvertempHiThe cabinet's Ambient Air Sensor detected a change in air temperature entering the over-temp-high range. The Cabinet will be shutting itself down to prevent co…
1.3.6.1.4.1.11.2.23.35.7828NodehpevtInletOvertempLoThe cabinet's Ambient Air Sensor detected a change in air temperature crossing to the low range. The air temperature may be rising or falling. This is just a r…
1.3.6.1.4.1.11.2.23.35.7829NodehpevtInletOvertempMidThe cabinet's Ambient Air Sensor detected a change in air temperature crossing to the mid range. The air temperature may be rising or falling. This is just a r…
1.3.6.1.4.1.11.2.23.35.7836NodehpevtIofanFailAn IO Chassis cooling fan has failed. Depending on the number of fans still operating, the cabinet may or may not shut down. View Error Log entries to determin…
1.3.6.1.4.1.11.2.23.35.7842NodehpevtPowerOverloadThis code is issued when the Cabinet Power supplied (number of Bulk Power Supplies times power output per each) minus the estimated Cabinet Power consumed drop…
1.3.6.1.4.1.11.2.23.35.7845NodehpevtShutdownBlowrAfter a BLOWR_FAIL, there were N-1 blowers functioning. This is an illegal condition causing immediate cabinet shutdown to prevent component damage.
1.3.6.1.4.1.11.2.23.35.7846NodehpevtShutdownIofanAfter a IOFAN_FAIL, there were N-1 fans functioning. This is an illegal condition causing immediate cabinet shutdown to prevent component damage.
1.3.6.1.4.1.11.2.23.35.7849NodehpevtXucFanFailOne of two fans in the Utility chassis of the IO Expansion Cabinet has failed.
1.3.6.1.4.1.11.2.23.35.7855NodehpevtCluWatchdogResetThe Watchdog Timer checks for inactivity, or hung state, of the Cabinet Level Utilities (CLU) portion of the UGUY. During activity, the timer is continually re…
1.3.6.1.4.1.11.2.23.35.7856NodehpevtEepromInvalidCksmAn invalid checksum was received when reading the FRUID EEPROM for the device named in the chassis code. If this is a single error, the fault lies with the nam…
1.3.6.1.4.1.11.2.23.35.7858NodehpevtHbpbBoardPowerFaultOne or more of the System Backplane Power Boards is reporting a DC Fault through the System Backplane Local Power Monitor. The physical location of the failing…
1.3.6.1.4.1.11.2.23.35.7863NodehpevtHiobEepromRdFailAn attempt to read the EEPROM (FRUID) on the IO Backplane Board failed.
1.3.6.1.4.1.11.2.23.35.7864NodehpevtHiopbEepromRdFailAn attempt to read the EEPROM (FRUID) on the IO Backplane Power Board failed.
1.3.6.1.4.1.11.2.23.35.7865NodehpevtHiopbLpmFltRdFailAn attempt to read the Local Power Monitor Fault register on the IO Backplane Power Board failed.
1.3.6.1.4.1.11.2.23.35.7866NodehpevtHiopbOvertempThe Local Power Monitor of the named IO Chassis is reporting a Power Brick over temperature condition.
1.3.6.1.4.1.11.2.23.35.7867NodehpevtHiopbPowerFaultThe Local Power Monitor on the named IO Chassis has reported a power fault condition.
1.3.6.1.4.1.11.2.23.35.7871NodehpevtHiopbVoltMrgnFailThe Local Power Monitor on the named IO Power Board failed to properly margin the power as commanded.
1.3.6.1.4.1.11.2.23.35.7873NodehpevtSbchEepromRdFailEither by command or as part of initialization, the data from a FRUID EEPROM failed a read command. This does not necessarily mean the FRU has failed, just tha…
1.3.6.1.4.1.11.2.23.35.7874NodehpevtUguyEepromRdFailEither by command or as part of initialization, the data from a FRUID EEPROM failed a read command. This does not necessarily mean the FRU has failed, just tha…
1.3.6.1.4.1.11.2.23.35.7875NodehpevtSysBkpEepromRdFailAn attempt to read the EEPROM (FRUID) on the System Backplane failed
1.3.6.1.4.1.11.2.23.35.7877NodehpevtSysBkpI2cRdFailA read command on the system backplane I2C bus failed.
1.3.6.1.4.1.11.2.23.35.7878NodehpevtSysBkpI2cWrFailA write command on the system backplane I2C bus failed. The type of command that failed can be identified by the activity status field (last byte) of the encod…
1.3.6.1.4.1.11.2.23.35.7879NodehpevtSysBkpPowerFaultThe Local Power Monitor on the named System Backplane has detected a power fault. The failing Backplane Power Board status is read from the Backplane LPM I2C i…
1.3.6.1.4.1.11.2.23.35.7880NodehpevtSysBkpVoltMrgnFailMargining voltage to the System Backplane has failed.
1.3.6.1.4.1.11.2.23.35.7891NodehpevtWriteFruDataFailAn attempt to write data to the FRUID EEPROM by the MFG level MP command WF failed. The FRU handle of the failing FRUID is embedded in the two uppermost bytes …
1.3.6.1.4.1.11.2.23.35.7892NodehpevtCpuFanFailThe fan on a CPU is not operating in a manner that provides enough air flow to cool the processor
1.3.6.1.4.1.11.2.23.35.7893NodehpevtCpuFanSlowThe fan on a CPU is operating in a manner that provides enough air flow to cool the processor but is not at normal operation
1.3.6.1.4.1.11.2.23.35.7894NodehpevtDnaFanFailThe fan on a CC chip is not operating in a manner that provides enough air flow to cool the processor
1.3.6.1.4.1.11.2.23.35.7895NodehpevtDnaFanSlowThe fan on a CC chip is operating in a manner that provides enough air flow to cool the processor but is not at normal operation
1.3.6.1.4.1.11.2.23.35.7896NodehpevtPdhcToSysfwRevMismtchSystem FW and the PDHC have incompatible shared memory interface revisions. Data byte 0 is the PDHC's supported ICM revision number. Data byte 1 is System FW's…
1.3.6.1.4.1.11.2.23.35.7902NodehpevtPdhCtrlrFwMismatchThe MP checked the FW revision of the PDHC identified in the physical location data field and discovered that it did not recognize the revision as one that it …
1.3.6.1.4.1.11.2.23.35.7903NodehpevtCellPowerFaultThe local Power Monitor is reporting a fault with the named Cell Power Board. The data field of this event can be decoded as follows where a bit set in any of …
1.3.6.1.4.1.11.2.23.35.7938NodehpevtCpuInitNodeErrorThe CPU node retuned an error when calling its initialize node function. The specific status is displayed in the data field.
1.3.6.1.4.1.11.2.23.35.7939NodehpevtCpuExecuteCmdErrorExecuteCommand issues commands that execute on remote CPUs via IPI interrupts. If the command failed to execute, this event is printed and the data field conta…
1.3.6.1.4.1.11.2.23.35.7940NodehpevtCpuCmdStateInvalidA remote CPU is in a state where it cannot receive and execute a new command. The current status of the CPU is provided in the data field.
1.3.6.1.4.1.11.2.23.35.7948NodehpevtCpuPalProcErrorAn error was encountered when executing a PAL_PROC. This code will be emitted in pairs. The Proc INDEX will be in the data of the first chassis code. The statu…
1.3.6.1.4.1.11.2.23.35.7953NodehpevtBootCpuLoadingErrorCPUs not loaded in correct order. Correct loading order is CPU 0, 1, 2, 3.
1.3.6.1.4.1.11.2.23.35.7963NodehpevtXbcPersistantErrorThe XBC logged a SBE or LPE after they should have been cleared. Either the clear failed, or a new error was logged immediately. Data field: XBC number (32:43)…
1.3.6.1.4.1.11.2.23.35.7964NodehpevtXbcLinkTestErrorThe CC to XBC Link pattern test failed. Data Field: This event will be emitted three times 1st event: XBC number (32:43), port number (44:55) 2nd event: expect…
1.3.6.1.4.1.11.2.23.35.7965NodehpevtPltfrmStorageReadErrSystem firmware was unable to complete a platform storage read command from the utilities system. The exact status printed in the data field.
1.3.6.1.4.1.11.2.23.35.7966NodehpevtPltfrmStorageWriteErrSystem firmware was unable to complete a platform storage write command. The actual status is returned in the data field.
1.3.6.1.4.1.11.2.23.35.7973NodehpevtTreeNodeErrorSequencerThe Sequencer was unable to find the tree node it needed to complete an operation. The tree node is in the ASCII in the data field.
1.3.6.1.4.1.11.2.23.35.7974NodehpevtPartitionVariableErrorSystem firmware attempted to read a partition variable from the GSP and store it in options. An error was encountered during this process. The data field conta…
1.3.6.1.4.1.11.2.23.35.7975NodehpevtCellRedundtPowerFaultOne or more power converters on the Cell or Cell Power Board has reported a fault. However, because of redundancy in the power system, the power to the Cell is…
1.3.6.1.4.1.11.2.23.35.8009NodehpevtPalProcConfigIncompatibleCPUProcConfigValue setting in options as been compared with what is reported by PAL as settable and CPUProcConfigValue is specifying at least one bit that is n…
1.3.6.1.4.1.11.2.23.35.8010NodehpevtPalGetProcFeaturesFailedSystem firmware was unable to successfully issue the PAL_GET_PROC_FEATURES PAL proc. The data field is unused
1.3.6.1.4.1.11.2.23.35.8127NodehpevtPdhcCriticalDebugThis event is a tool to aid in the debugging and testing of firmware.
1.3.6.1.4.1.11.2.23.35.8128NodehpevtCluUndefinedCaseThe CLU has encountered an undefined case in its control flow.
1.3.6.1.4.1.11.2.23.35.8130NodehpevtCellVoltageMarginUnknThe Cell voltage margin settings do not match the Normal, +5%, or -5% values.
1.3.6.1.4.1.11.2.23.35.8131NodehpevtPdhcAssertionFailedFor debug purposes, many assumptions made by the PDHC developer(s) are checked at run-time. If this event log is seen, it indicates that the hardware or softwa…
1.3.6.1.4.1.11.2.23.35.8132NodehpevtPdhcFirmwareUnknownErrAn unknown error has been detected by the PDHC firmware. For developer debug purposes, the data field describes where in the code that the error was detected. …
1.3.6.1.4.1.11.2.23.35.8133NodehpevtPdhcI2cWriteFailedAn attempt to write to a device on the PDHC's I2C bus has failed. The devices on the I2C bus are the Cell's FRU EEPROM, the Cell Power Board's FRU EEPROM, the …
1.3.6.1.4.1.11.2.23.35.8134NodehpevtPdhcI2cReadFailedAn attempt to read from a device on the PDHC's I2C bus has failed. The devices on the I2C bus are the Cell's FRU EEPROM, the Cell Power Board's FRU EEPROM, the…
1.3.6.1.4.1.11.2.23.35.8135NodehpevtPdhcSmbusWriteFailedAn attempt to write to a device on the PDHC's SM bus has failed. The devices on the SM bus are the CPU modules' FRU EEPROMs, the CPU modules' Processor Informa…
1.3.6.1.4.1.11.2.23.35.8136NodehpevtPdhcSmbusReadFailedAn attempt to read from a device on the PDHC's SM bus has failed. The devices on the SM bus are the CPU modules' FRU EEPROMs, the CPU modules' Processor Inform…
1.3.6.1.4.1.11.2.23.35.8137NodehpevtFrequencyProgramFailedThe PDHC did not read valid frequency information from the CPU modules' or Cell's FRU EEPROMs, or the frequency registers would not update properly. Following …
1.3.6.1.4.1.11.2.23.35.8138NodehpevtSysFwFlashUpdateErrorAn error has occurred while updating System FW. More details about the update failure may be available as displayed by the Firmware Update Utility (FWUU).
1.3.6.1.4.1.11.2.23.35.8139NodehpevtPdhcUnexpectedResetThe PDHC firmware was reset for some unknown reason.
1.3.6.1.4.1.11.2.23.35.8140NodehpevtCpuTmpSensorSetupFailA hardware fault prevented the PDHC from configuring the thermal sensor(s) on one or more of the CPU modules. Following detection of this fault condition, the …
1.3.6.1.4.1.11.2.23.35.8141NodehpevtCpuModuleThermalertA CPU module's temperature has exceed the high temperature threshold. As a result of this event, an irrevocable 2 minute timer will begin. At the end of 2 minu…
1.3.6.1.4.1.11.2.23.35.8143NodehpevtPdhcFlashUpdateErrorAn error occurred while updating the PDHC firmware. More specific details of the update error may be displayed by the Firmware Update utility running on the MP.
1.3.6.1.4.1.11.2.23.35.8147NodehpevtCellTypMismatchWSysfwThe cell type (IPF or PA) does not match System FW type. The cell type is detected based on information stored in CPU modules' FRUID EEPROMs. The System FW typ…
1.3.6.1.4.1.11.2.23.35.8149NodehpevtPdhcPdhArbiterTimeoutThis event is emitted after the PDHC has waited longer than a maximum expected time for the PDH arbiter to grant it control of the PDH bus. The PDHC will conti…
1.3.6.1.4.1.11.2.23.35.8151NodehpevtPdhcGetSm4TimeoutThis event is emitted after the PDHC has waited longer than a maximum expected time to obtain control of the PDH bus semaphore. The PDHC will continue waiting …
1.3.6.1.4.1.11.2.23.35.8153NodehpevtIpmiBmc2hostMsgFailureThis event indicates that an error occurred while transmitting an IPMI message in the BMC2HOST direction. The data field contains more detailed information abo…
1.3.6.1.4.1.11.2.23.35.8154NodehpevtEfiDebugLevelTokenErrEFI was unable to read the initial debug level from the BMC token. EFI will continue with an unknown value for the debug level. Data Field: Return status from …
1.3.6.1.4.1.11.2.23.35.8156NodehpevtXbcPortNotLandminedA XBC port was unexpectedly found to not be landmined. The data field consists of the XBC number (32:43) and the port number (44:55).
1.3.6.1.4.1.11.2.23.35.8159NodehpevtFabricValidateErrorThe number of landmined XBC ports was not within the allowable range. There is a minimum number of landmined ports because some ports are always unused. There …
1.3.6.1.4.1.11.2.23.35.8184NodehpevtFabricISRInvalidBkpData field contains the backplane type found. During Intra SKD Routing, the backplane type detected was either a Medel backplane or was unrecognized. The backp…
1.3.6.1.4.1.11.2.23.35.8186NodehpevtFabricXinWrZeroErrMaskErrorPrior to initializing the CC to XBC link, the XIN error mask should be zeroed out to prevent spurious errors from interfering with the link initialization. Thi…
1.3.6.1.4.1.11.2.23.35.8187NodehpevtFabricCcPriModeRegRdStatusThe Coherency Controller's (CC) XIN link did not initialize properly. The data field contains the return status from an attempted read of the CC Primary Error …
1.3.6.1.4.1.11.2.23.35.8188NodehpevtFabricCcPriModeRegRdDataThe Coherency Controller's (CC) XIN link did not initialize properly. The data field contains the data read from the CC Primary Error Mode CSR.
1.3.6.1.4.1.11.2.23.35.8189NodehpevtFabricCcErrMaskRegRdStatusThe Coherency Controller's (CC) XIN link did not initialize properly. The data field contains the return status from an attempted read of the CC Primary Error …
1.3.6.1.4.1.11.2.23.35.8190NodehpevtFabricCcErrMaskRegRdDataThe Coherency Controller's (CC) XIN link did not initialize properly. The data field contains the data read from the CC Error Mask CSR.
1.3.6.1.4.1.11.2.23.35.8194NodehpevtFabricXingNeighborPortBadThe neighbor's port connected to the link being crossed is not routable. This was the first attempt to cross the link, PDC will now look for another link it ca…
1.3.6.1.4.1.11.2.23.35.8195NodehpevtFabricISRRdFwdProgErrFabric read error. Data field: (XBC number << 32 | return status)
1.3.6.1.4.1.11.2.23.35.8198NodehpevtFabricGetNeighborMaxLinksBrokenToo many crossbar links are broken. Cell cannot boot, halting. Data field: XBC number << 32
1.3.6.1.4.1.11.2.23.35.8199NodehpevtPmAssertionFailedFor debug purposes, many assumptions made by the PM developer(s) are checked at run-time. If this event log is seen, it will either indicate that the hardware …
1.3.6.1.4.1.11.2.23.35.8200NodehpevtPmFirmwareUnknownErrAn unknown error has been detected by the PM firmware. For developer debug purposes, the data field describes where in the code that the error was detected. Da…
1.3.6.1.4.1.11.2.23.35.8202NodehpevtPmCriticalDebugThis event is a tool to aid in the debugging and testing of firmware.
1.3.6.1.4.1.11.2.23.35.8205NodehpevtFabricLinkCorErrTestFailureFailed link testing to ensure that SBE and LPE errors are detected properly by the XBC. The XBC did not detect any errors. Data field indicates the return stat…
1.3.6.1.4.1.11.2.23.35.8206NodehpevtInvalidCabinetNumberThe data field contains the cabinet number that is invalid
1.3.6.1.4.1.11.2.23.35.8207NodehpevtPdIncompatibleFwRevsThe cell indicated in the data field is at a different firmware revision than the reporting cell. This is determined by evaluating the checksums of the 2 rom i…
1.3.6.1.4.1.11.2.23.35.8212NodehpevtPmI2cWriteFailedAn attempt to write to a device on the PM's I2C bus has failed. The Data field contains information that can identify the exact device that has failed. Refer t…
1.3.6.1.4.1.11.2.23.35.8214NodehpevtPmI2cReadFailedAn attempt to read from a device on the PM's I2C bus has failed. This event is only emitted when the PM is reading a BPS's. The Data field contains information…
1.3.6.1.4.1.11.2.23.35.8216NodehpevtCellInfoErrorAn error was encountered trying to obtain the data required for the cell information structure in ICM. The data field is an ASCII message that indicates the in…
1.3.6.1.4.1.11.2.23.35.8218NodehpevtSlaveConsoleSetupErrorAn error was encountered establishing the slave cells use of the diva console.
1.3.6.1.4.1.11.2.23.35.8219NodehpevtRegistryMoveToCoreCellErrorAn error was encountered trying to relocate the registry on a slave cell to point to the core cells main memory structures.
1.3.6.1.4.1.11.2.23.35.8220NodehpevtProfileGroupCCrcErrorThe Calculated CRC for the group C Partition Profile did not match the stored value. The expected value and the actual value will be emitted in 2 sequential ch…
1.3.6.1.4.1.11.2.23.35.8238NodehpevtMcCoreCellSelectFailNot able to find a core cell in the PD during a global MCA error processing.
1.3.6.1.4.1.11.2.23.35.8239NodehpevtFabricAssertFabricUtilsAn unexpected error occurred while initializing the fabric. The firmware is not able to analyze this error. Clues to the cause of this error may be found in th…
1.3.6.1.4.1.11.2.23.35.8240NodehpevtSalPmiFwErrorAn internal firmware error was encountered. This is usually caused by a bad parameter passed to a function, corrupt memory, corrupt malloc tables or something …
1.3.6.1.4.1.11.2.23.35.8243NodehpevtOlaWrongNumberCellsDuring the on line addition of a cell the partition adding the cell has determined inconsistent data as to which cell is being added. The cell addition will be…
1.3.6.1.4.1.11.2.23.35.8257NodehpevtFabricXbcRouteSourceCellPortErrAn error occurred while reading the routing from the source cell's port on the source XBC. Data Field: (source cell << 56 | source XBC << 32)
1.3.6.1.4.1.11.2.23.35.8261NodehpevtBootOlaCellIncompatibleOLA cell cannot be added because it has resources that are not compatible with those already in the partition. Data field specifies the physical location of th…
1.3.6.1.4.1.11.2.23.35.8263NodehpevtBootOlaCellDidNotReachRendezvousRoot Cell attempted to OLA a cell which hung somewhere in the OLA process - the cell released from BIB but never made it to its final rendezvous state. Data fi…
1.3.6.1.4.1.11.2.23.35.8264NodehpevtBootOlaCellStillAtBibRoot cell attempted to OLA a cell that was never released from BIB. Data field contains the physical location of the cell that is being OLAD.
1.3.6.1.4.1.11.2.23.35.8265NodehpevtBootOlaCellUnexpectedCellStatePartition attempted to OLA a cell in an unexpected Cell state. Data Field contains the unexpected cell state of the OLA cell. The OLA cell will NOT be added to…
1.3.6.1.4.1.11.2.23.35.8267NodehpevtBootOlaCellCantReachAliveCellsRoot cell will emit this chassis code indicating the OLA cell could reach all cells in the alive set of the existing partition. Data field will contain the phy…
1.3.6.1.4.1.11.2.23.35.8269NodehpevtBootMixedCpuCoreFreqInstalledCPU's of mixed maximum core frequencies are installed
1.3.6.1.4.1.11.2.23.35.8271NodehpevtXinInitIntermittentFailureThe Cell Controller-XBC link initialization is having an intermittent failure. The data field contains the number of initialization sequences that failed befor…
1.3.6.1.4.1.11.2.23.35.8643NodehpevtPdhErrClearOlaSteeringBitPDC failed clearing the OLA steering bit in the PDH FPGA microstatus register. Data field contains the physical location of the cell with the failure. This can…
1.3.6.1.4.1.11.2.23.35.8645NodehpevtBootOlaFailedUpdatePdAddrMapThe attempt to update the PD Addr Map to include OLA cell failed.
1.3.6.1.4.1.11.2.23.35.8646NodehpevtBootOlaFailedUpdatePdPdtAttempt to update the partition PDT with OLA cell PDT data has failed.
1.3.6.1.4.1.11.2.23.35.8647NodehpevtBootOlaFailedUpdateCellMapAttempt to update the cell map to include the OLA Cell failed
1.3.6.1.4.1.11.2.23.35.8648NodehpevtFabricCc2XbcLinkInitFailedFabric Discovery's final attempt to initialize the local cell's CC to Crossbar Chip (XBC) link has failed. This cell cannot talk to the fabric. Data: link init…
1.3.6.1.4.1.11.2.23.35.8652NodehpevtFwVirtualMappingErrorAn internal firmware error was encountered. This is usually caused by a bad parameter passed to a function, corrupt memory, corrupt malloc tables or something …
1.3.6.1.4.1.11.2.23.35.8676NodehpevtFabricXinInitWriteErrFailure while writing the XBC CSR containing the link status
1.3.6.1.4.1.11.2.23.35.8677NodehpevtFabricXinInitReadErrFailure while reading the XBC CSR containing the link status
1.3.6.1.4.1.11.2.23.35.8679NodehpevtFabricLinkInitIntermittentFailureFabric Discovery's attempt to initialize the local cell's CC to XBC link has failed. The link initialization sequence has an intermittent problem.
1.3.6.1.4.1.11.2.23.35.8690NodehpevtIodiscPciInitnodeErrorAn error was encountered while attempting to create and initialize a PCI device node
1.3.6.1.4.1.11.2.23.35.8691NodehpevtIodiscPciBusscanErrorAn error was encountered while scanning the PCI bus
1.3.6.1.4.1.11.2.23.35.8692NodehpevtIodiscPciInitbridgeErrorAn error was encountered while attempting to initialize a P2P bridge
1.3.6.1.4.1.11.2.23.35.8693NodehpevtIodiscPciIomapErrorInsufficient IO Port space to support the PCI card
1.3.6.1.4.1.11.2.23.35.8694NodehpevtIodiscPciMmiomapErrorInsufficient MMIO space to support the PCI card requirements
1.3.6.1.4.1.11.2.23.35.8709NodehpevtIodiscSbaInitnodeErrorAn error was encountered while attempting to initialize the SBA node
1.3.6.1.4.1.11.2.23.35.8710NodehpevtIodiscSbaDiscoverErrorAn error was encountered while attempting to discover SBA hardware
1.3.6.1.4.1.11.2.23.35.8711NodehpevtIodiscSbaResetErrorAn error was encountered while attempting to reset the SBA
1.3.6.1.4.1.11.2.23.35.8712NodehpevtIodiscIolinkErrorAn error was detected in the link between the CC and the I/O controller.
1.3.6.1.4.1.11.2.23.35.8713NodehpevtIodiscCableErrorAn SBA cable error has been detected
1.3.6.1.4.1.11.2.23.35.8714NodehpevtIodiscIoChassisPowerIdentified the cell number that is connected to the chassis.
1.3.6.1.4.1.11.2.23.35.8715NodehpevtIodiscLbaInitnodeErrorAn error occurred while attempting to create or initialize an LBA node
1.3.6.1.4.1.11.2.23.35.8716NodehpevtIodiscLbaWidthErrorAn error was encountered while attempting to configure LBA rope bundling width
1.3.6.1.4.1.11.2.23.35.8717NodehpevtIodiscLbaPhaseErrorerror code
1.3.6.1.4.1.11.2.23.35.8718NodehpevtIodiscLbaClearErrorAn error occurred while attempting to clear an LBA error log register
1.3.6.1.4.1.11.2.23.35.8719NodehpevtIodiscLbaLogErrorAn error was encountered while attempting to generate LBA error logs
1.3.6.1.4.1.11.2.23.35.8720NodehpevtIodiscLbaDiscoverErrorAn error was encountered while attempting to discover LBA hardware
1.3.6.1.4.1.11.2.23.35.8721NodehpevtIodiscLbaConfigErrorAn error occurred while attempting to configure the LBA hardware
1.3.6.1.4.1.11.2.23.35.8722NodehpevtIodiscLbaPciscanErrorAn error was encountered while attempting to scan the PCI bus
1.3.6.1.4.1.11.2.23.35.8723NodehpevtIodiscLbaPciconfigErrorAn error was encountered while attempting to configure PCI config space
1.3.6.1.4.1.11.2.23.35.8745NodehpevtBootOlaCellErrAccessCmplxProfileThe OLA cell failed accessing the complex profile. Cell will send Failed to OLA message back to partition and then reboot itself. Existing partition will not b…
1.3.6.1.4.1.11.2.23.35.8747NodehpevtBootFwRelocMemErrA Firmware tries to find a main memory block large enough meeting alignment requirements.
1.3.6.1.4.1.11.2.23.35.8752NodehpevtBootOlaCellNotConfigInCmplxProfileCell started OLA but is not configured in the complex profile of the partition. Cell will reboot to SINC_BIB. Existing partition will not be affected.
1.3.6.1.4.1.11.2.23.35.8756NodehpevtOptsNvmAllocErrorThe Options service received an error when attempting to allocate an NVRAM storage block. Either an error was returned from the call, or the call returned succ…
1.3.6.1.4.1.11.2.23.35.8757NodehpevtBootOlaUpdateRtcFailedOlaCellA failure occurred on the OLA cell during the attempt to synchronize its real time clock with the clock(s) in the existing partition. Data field contains physi…
1.3.6.1.4.1.11.2.23.35.8758NodehpevtSalInfoTimeoutAccess to SAL error log procedure timed out because the log facility was busy processing a request from another CPU. Data field indicates the SAL procedure ID.
1.3.6.1.4.1.11.2.23.35.8761NodehpevtPdhIprNotClearedOnCellThe PDH FPGA IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. The Data Filed in the Cell number. See the next Chassis Code to see the MAX_RD_CLR_IPR_…
1.3.6.1.4.1.11.2.23.35.8762NodehpevtPdhIprClearAttemptsIndicated the PDH FPGA IPR is not cleared after a number of PDC attempts. The Data Field contents the MAX_RD_CLR_IPR_TRIES. Please look at the previous Chassis…
1.3.6.1.4.1.11.2.23.35.8763NodehpevtBootOlaUpdateRtcFailedExistingCellattempt to synchronize the Real-Time Clock of the OLA cell with the existing partition failed because the RTC on the core cell could not be read.
1.3.6.1.4.1.11.2.23.35.8768NodehpevtMemIncompleteEchelonOne or more dimms are missing from the echelon given in the data field. The dimms may not be installed or firmware was not able to detect the dimms.
1.3.6.1.4.1.11.2.23.35.8771NodehpevtFabricRdPortStatePortInvalidThe code that reads the port state (landmine vs. healthy) expects a XBC internal port number, it received bogus data. The port state cannot be read. Data Field…
1.3.6.1.4.1.11.2.23.35.8772NodehpevtFabricWrPortStatePortInvalidThe code that writes the port state (landmine vs. healthy) expects a XBC internal port number, it received bogus data. The port state cannot be read. Data Fiel…
1.3.6.1.4.1.11.2.23.35.8784NodehpevtMainBpLpmFltThe main backplane is reporting the LPM status as fault.
1.3.6.1.4.1.11.2.23.35.8787NodehpevtIoBpLpmFltThe IO backplane has reported a local power monitor fault.
1.3.6.1.4.1.11.2.23.35.8797NodehpevtCmplxProfileInitFailedSystem firmware was unable to default the complex profile
1.3.6.1.4.1.11.2.23.35.8798NodehpevtPalSetProcFeaturesFailedFirmware call to set processor feature resulted in an error.
1.3.6.1.4.1.11.2.23.35.8806NodehpevtActiveLogNotFoundThis chassis code shows that the error log space in the NVRAM has not been allocated for the current error event. This will be emitted out whenever a error sec…
1.3.6.1.4.1.11.2.23.35.8807NodehpevtReachedMaxErrorLogsThis indicates that the error logs for a particular event type have reached the maximum allowed to be stored in the NVRAM. The event type is indicated in the d…
1.3.6.1.4.1.11.2.23.35.8814NodehpevtOldNoCellToDeleteSystem firmware has been invoked to perform a cell delete operation but no cell in the system appears to be ready for deletion.
1.3.6.1.4.1.11.2.23.35.8817NodehpevtBpsOvercurrentThe bulk power supply is overcurrent
1.3.6.1.4.1.11.2.23.35.8818NodehpevtBpsWarnOtData: Bulk location.
1.3.6.1.4.1.11.2.23.35.8819NodehpevtErmOutOfHeapError Response Mode code attempted a malloc of heap space that failed.
1.3.6.1.4.1.11.2.23.35.8821NodehpevtMemDimmUnsupportedThe dimm in the physical location given by the data field is not supported on this platform. The dimm may not be supported by the hardware, or the dimm may not…
1.3.6.1.4.1.11.2.23.35.8828NodehpevtOptsMallocErrorThe OPTIONS component was unable to allocate NVRAM memory in order to store a non-volatile variable. The storage area for NVRAM options may be full, or there m…
1.3.6.1.4.1.11.2.23.35.8837NodehpevtCellHwDegradedA dimm or CPU has failed and is not operational for the system. This event is emitted prior to determining if the cell should be integrated into the Partition.
1.3.6.1.4.1.11.2.23.35.8839NodehpevtNotIntegratingCellA cpu or dimm error has been detected, and the Complex Profile, Cell Integration Table, Cell integration policy says to not integrate the cell into the PD. The…
1.3.6.1.4.1.11.2.23.35.8842NodehpevtIoContextCorruptErrThe IO error context is corrupt. This will impair IO error reporting.
1.3.6.1.4.1.11.2.23.35.8843NodehpevtIoRopeFatalA rope went fatal from the SBA to the LBA. If all the ropes go fatal the IO subsystem is dead. Any I/O below the rope will not be accessible. The data field gi…
1.3.6.1.4.1.11.2.23.35.8844NodehpevtIoBusFatalA PCI bus on the system is fatal. Any device on this bus is unavailable. Firmware was unable to complete card initialization due to an error. Data field contai…
1.3.6.1.4.1.11.2.23.35.8845NodehpevtIoRopeUnitFatalOne of the rope units in the SBA failed. If all of the rope units fail, then IO will not be available on this cell.
1.3.6.1.4.1.11.2.23.35.8851NodehpevtPdhFlashWriteEnableBitSetNowClearedThe System Flash Write Enable bit is incorrectly set and now clearing by PDC. The Data field contains the value of PDH Miscellaneous Signal Register read befor…
1.3.6.1.4.1.11.2.23.35.8855NodehpevtFirmwareInitErrorSystem firmware encountered an error while trying to perform an operation during system initialization. This event ID will always be emitted before an event ID…
1.3.6.1.4.1.11.2.23.35.8857NodehpevtMcIncompleteCpuSetThis means that all the cpus in the cell did not show up.
1.3.6.1.4.1.11.2.23.35.8858NodehpevtMcIncompleteCellSetThis means that all the cells did not rendezvous during the PD rendezvous. The data part will contain the Expected data and the actual mask of the cells that r…
1.3.6.1.4.1.11.2.23.35.8859NodehpevtMcTreeCheckFailedThe FW tree sanity check failed during the MCA error processing.
1.3.6.1.4.1.11.2.23.35.8860NodehpevtMcRegistryCheckFailedThis means that the registry sanity check failed during MCA error handling.
1.3.6.1.4.1.11.2.23.35.8861NodehpevtMcDuringOsMcaThis means that MCA occurred while OS_MCA was performing error recovery.
1.3.6.1.4.1.11.2.23.35.8864NodehpevtMcMemDumpAbandonThis means that memory dump will be abandoned due to work-around for CN2272. This happens when one of the Blocking timeout in the Processor input block of the …
1.3.6.1.4.1.11.2.23.35.8865NodehpevtMcFwTreeNotCompleteThe firmware tree is not complete and hence there will be no PD rendezvous.
1.3.6.1.4.1.11.2.23.35.8872NodehpevtAcpiConfigMismatchThe firmware parameter that defines the ACPI configuration is inconsistent in at least one of the cells in the partition.
1.3.6.1.4.1.11.2.23.35.8873NodehpevtFabricXinErrOrderStatusClrFailedWriting the XIN_ERR_ORDER_STATUS register of the CC failed. This is some sort of a hardware failure. Data Field: return status
1.3.6.1.4.1.11.2.23.35.8876NodehpevtFabricAssertFabricInitAn unexpected error occurred while initializing the fabric. The firmware is not able to analyze this error. Clues to the cause of this error may be found in th…
1.3.6.1.4.1.11.2.23.35.8877NodehpevtInvalidPiromDataA value read by the PDHC from a CPU module's Processor Information ROM was not within acceptable limits.
1.3.6.1.4.1.11.2.23.35.8882NodehpevtSettingFreqRatiosErrorAn invalid parameter was specified when trying to set the cpu bus config register, cpu frequencies ratio field. Valid range is 0xe - 0x17
1.3.6.1.4.1.11.2.23.35.8883NodehpevtOptsBlockCksumErrorThe overhead structure of the OPTIONS block in NVRAM has a checksum error.
1.3.6.1.4.1.11.2.23.35.8894NodehpevtFabricColaLocalCcLinkNotInitDuring a cell OLA, the link on the local cell failed to initialize. Data Field: (my cell << 32) | XIN Link State
1.3.6.1.4.1.11.2.23.35.8895NodehpevtFabricXinInitDisableWrErrorAn attempt to disable the fabric link failed because writing the CC CSR failed. Data Field: (cell << 56) | return status
1.3.6.1.4.1.11.2.23.35.8896NodehpevtFabricXinErrMaskUnknownBkpCould not determine the system type in order to write the appropriate error mask for the fabric link. Data Field: system type
1.3.6.1.4.1.11.2.23.35.8897NodehpevtFabricXinWrErrMaskErrorFailed writing the XIN error mask for CC's fabric link. Data Field: (cell << 56) | return status
1.3.6.1.4.1.11.2.23.35.8898NodehpevtFabricXinRdErrMaskErrorCould not read the XIN Link error mask register. Data Field: (cell << 56) | return status
1.3.6.1.4.1.11.2.23.35.8900NodehpevtFabricInitCcLinkFailureThe CC to CC link initialization sequence has failed. Data Field: link init status
1.3.6.1.4.1.11.2.23.35.8906NodehpevtResetCommandErrorAn error occurred while trying to notify the MP that a reset is about to occur (QPartitionReleaseBIB command). The status is in the data field.
1.3.6.1.4.1.11.2.23.35.8926NodehpevtFabricInitCcLinkDisableErrA fabric access error occurred while trying to disable the CC to CC link on a single cell Medel system. This cell will halt. Data field: error status
1.3.6.1.4.1.11.2.23.35.8930NodehpevtFabricSetPortStateGetSm4ErrWhile updating the Port State register, the cell could not get the XBC semaphore. Data field is: (Port Num << 44 | XBC num << 32 | return status). Where return…
1.3.6.1.4.1.11.2.23.35.8931NodehpevtFabricSetPortStateRlsSm4ErrWhile updating the Port State register, the cell could not get the XBC semaphore. Data field is: (Port Num << 44 | XBC num << 32 | return status). Where return…
1.3.6.1.4.1.11.2.23.35.8936NodehpevtFabricAssertFabricErrAn unexpected error occurred while initializing the fabric. The firmware is not able to analyze this error. Clues to the cause of this error may be found in th…
1.3.6.1.4.1.11.2.23.35.8939NodehpevtFabricXinLinkAlreadyInitWhile attempting to initialize the XIN link, it was found to already be initialized. A firmware assertion has failed. The link will not be re-initialized and p…
1.3.6.1.4.1.11.2.23.35.8940NodehpevtNoCpuModulesFoundByPdhcThe PDHC FW could not detect any CPU modules on its Cell board, so it is holding the Cell in reset.
1.3.6.1.4.1.11.2.23.35.8941NodehpevtCpuModCompatMismatchThe Cell has been disabled by PDHC FW because the CPU modules are not compatible. Compatibility is determined based on data stored in the Scratch/FRUID EEPROM …
1.3.6.1.4.1.11.2.23.35.8942NodehpevtBadCpuModScratchCksumThe Cell has been disabled because of invalid data in a CPU module Scratch EEPROM. PDHC FW checksums the FRUID data stored in each CPU module's Scratch EEPROM.…
1.3.6.1.4.1.11.2.23.35.8954NodehpevtPdhBatteryLowWarningThe battery voltage level is low for the cell. This indicates that the NVRAM will not be saved if the power is removed.
1.3.6.1.4.1.11.2.23.35.8959NodehpevtFabricRouteXbcCopyRoutingErrThere was an error while copying the routing for the XBC to the local XBC port. The cell will reset. Data: (XBC port << 44) | (XBC num << 32) | return status
1.3.6.1.4.1.11.2.23.35.8960NodehpevtFabricCopyRdBackFailedThe read immediately after a write while copying routing registers failed. Data: whether or not the XBC Key was enabled
1.3.6.1.4.1.11.2.23.35.8962NodehpevtFabricRtgCompleteSm4RlsErrFailed to release a XBC Semaphore while marking each XBC in the complex to indicate that routing has completed. Data: (XBC num << 32) | return value
1.3.6.1.4.1.11.2.23.35.8964NodehpevtFabricRtgCompleteWrFwdPrgErrWriting this XBC's forward progress register failed. Data: (XBC num << 32) | return value
1.3.6.1.4.1.11.2.23.35.8965NodehpevtFabricRtgCompleteSm4AccessErrFailed to get a XBC Semaphore while marking each XBC in the complex to indicate that routing has completed. Skipping this XBC. Data: (XBC num << 32) | return v…
1.3.6.1.4.1.11.2.23.35.8966NodehpevtFabricRtgCompleteTopologyErrReading this XBC's topology register failed. Data Field: (xbc num << 32) | return status
1.3.6.1.4.1.11.2.23.35.8968NodehpevtFabricRouteTraversableCc2CcErrCould not check the traversability between two cells on an XBCless platform. Data field: return status (1 = SUCCESS, 0 = FALSE, -1 = FAILURE)
1.3.6.1.4.1.11.2.23.35.8969NodehpevtFabricDataRouteTraversableCc2CcErrCould not check the traversability between two cells on an XBCless platform. Data field: return status (1 = SUCCESS, 0 = FALSE, -1 = FAILURE)
1.3.6.1.4.1.11.2.23.35.8970NodehpevtFabricCc2ccTraverseLclXinRdErrWhile checking traversability of a 2 cell back to back system, there was an error reading the local cell's XIN block. Data Field: return status (1 or -1)
1.3.6.1.4.1.11.2.23.35.8971NodehpevtFabricCc2ccTraverseRmtXinRdErrWhile checking traversability of a 2 cell back to back system, there was an error reading the local cell's XIN block. Data Field: return status (1 or -1)
1.3.6.1.4.1.11.2.23.35.8972NodehpevtFabricCc2ccTraverseLclNotInitCould not traverse to the target cell. The XIN link is either not initialized, or is not connected to the target cell. However, the target cell is designated t…
1.3.6.1.4.1.11.2.23.35.8973NodehpevtFabricCc2ccTraverseRmtNotInitCould not traverse to the target cell. The XIN link is either not initialized, or is not connected to the target cell. However, the target cell is designated t…
1.3.6.1.4.1.11.2.23.35.8974NodehpevtFabricDisableXinLinkReadErrError reading the XIN_LINK_STATE register of the CC. This occurred while verifying that the link had been disabled. Data Field: cell being read << 56 | return …
1.3.6.1.4.1.11.2.23.35.8975NodehpevtFabricXinInitRetryReadErrFailure while reading the XBC CSR containing the link status. This occurred while attempting the retry process to get XBC to CC link initialized. Data Field: l…
1.3.6.1.4.1.11.2.23.35.8976NodehpevtFabricAssertFabricCcAn unexpected error occurred while initializing the fabric. The firmware is not able to analyze this error. Clues to the cause of this error may be found in th…
1.3.6.1.4.1.11.2.23.35.8979NodehpevtCpuRestrictedThe CPU that just completed self tests is functionally or performance restricted. The data field contains the Self Test State Parameter. The 2-bit state field …
1.3.6.1.4.1.11.2.23.35.8981NodehpevtPdhInvalidRtcClearedThe RTC was found to be invalid and has been cleared
1.3.6.1.4.1.11.2.23.35.8982NodehpevtLstNotRunSystem firmware requested that Late Self Tests be run by PAL, but PAL returned that the tests did not actually run on the processor. The data field indicates t…
1.3.6.1.4.1.11.2.23.35.8983NodehpevtBootSetCellStateFabricFailureAn attempt to update the cell state has failed due to a fabric crossbar failure. The cell number being updated in bits 63:56, while the traversable cell set (t…
1.3.6.1.4.1.11.2.23.35.8984NodehpevtBootResetCellStateFailureFailed to reset a cell due to an error setting the cell's state. The cell will not be reset with the other cells in the PD. The cell number is reported in the …
1.3.6.1.4.1.11.2.23.35.9000NodehpevtMemChipspareDeallocRankSFW has detected that a DRAM is failing on the DIMM specified by the physical location. The rank the failing DIMM is part of will be deallocated.
1.3.6.1.4.1.11.2.23.35.9019NodehpevtClockFreqErrorInternal CPU clocks are not valid when compared with the real time clock. The data field contains the hex value of the elapsed time. If this value is off a sma…
1.3.6.1.4.1.11.2.23.35.9020NodehpevtFabricColaInitTraversableErrCould not traverse the fabric to the cell being added. Data field: (chosen cell << 56) | return status, where -1 = failure
1.3.6.1.4.1.11.2.23.35.9021NodehpevtFabricAttemptFocusedRerouteA XBC port was found to be unhealthy on this reboot. This cell will attempt to route around it. Data field: (local Cell << 56) | (local internal Port << 44) | …
1.3.6.1.4.1.11.2.23.35.9022NodehpevtFabricCellRerouteNinfoErrError getting the XBC port's expected neighbor from a firmware table. Data field: 0 (SUCCESS) or -1 (FAILURE)
1.3.6.1.4.1.11.2.23.35.9038NodehpevtBootWakeCpuIsCpuDeconfigErrEither PDC is going to halt the cell or reset the partition because PDC was unable to access the PDH memory of either its local cell or another cell in the par…
1.3.6.1.4.1.11.2.23.35.9039NodehpevtBootWakeCpuGetCountersErrEither PDC is going to halt the cell or reset the partition because PDC was unable to access the PDH memory of either its local cell or another cell in the par…
1.3.6.1.4.1.11.2.23.35.9040NodehpevtBootWakeCpuGetStructAddrErrEither PDC is going to halt the cell or reset the partition because PDC was unable to access the PDH memory of either its local cell or another cell in the par…
1.3.6.1.4.1.11.2.23.35.9041NodehpevtBootCheckCpu4CompletionErrEither PDC is going to halt the cell or reset the partition because PDC was unable to access the PDH memory of either its local cell or another cell in the par…
1.3.6.1.4.1.11.2.23.35.9042NodehpevtBootCheckCpuGetStructAddrErrEither PDC is going to halt the cell or reset the partition because PDC was unable to access the PDH memory of either its local cell or another cell in the par…
1.3.6.1.4.1.11.2.23.35.9043NodehpevtReconfigResetScheduledThere is a need to reset the cell for reconfiguration, but it cannot be done yet because the cell has not reported at BIB. The Reset is being scheduled to be p…
1.3.6.1.4.1.11.2.23.35.9045NodehpevtProfileWrongArchTypeWhen processing the complex profile, the an unexpected 'Architecture Type' was specified in the PA/IA Arch field. The actual data found is displayed.
1.3.6.1.4.1.11.2.23.35.9046NodehpevtBootCheckCpuIsDeconfigErrWhile trying to determine whether or not a particular processor has completed the task for which it was awakened, PDC was unable to access the deconfig byte in…
1.3.6.1.4.1.11.2.23.35.9047NodehpevtBootCheckCpuGetCountersErrWhile trying to determine whether or not a particular processor has completed the task for which it was awakened, PDC was unable to access the CPU's sleep and …
1.3.6.1.4.1.11.2.23.35.9049NodehpevtBootPdMonarchRtnFromSwSetFpErrWhile trying to determine whether or not a particular processor has completed the task for which it was awakened, PDC was unable to access the CPU's forward pr…
1.3.6.1.4.1.11.2.23.35.9051NodehpevtBootSlaveRtnFromFwSetFpErrWhile trying to determine whether or not a particular processor has completed the task for which it was awakened, PDC was unable to access the CPU's Forward Pr…
1.3.6.1.4.1.11.2.23.35.9052NodehpevtBootProblemBranchingToPgzLocationAt a certain point in PDC boot, all of the processors in the partition except the PD monarch are put into a sleep, and they remain there until they are awakene…
1.3.6.1.4.1.11.2.23.35.9084NodehpevtBootBadCpuOrderThe Data Field contains the value used to determine a valid order.
1.3.6.1.4.1.11.2.23.35.9364NodehpevtBootSlpWakeCntrsStructAddrErrWhile trying to get the sleep counter and the wakeup counter for a particular processor, which is kept in a data structure in PDH memory, PDC was unable to det…
1.3.6.1.4.1.11.2.23.35.9365NodehpevtBootGetSleepTimeoutStructAddrErrError occurred accessing a PDC data structure. Depending upon the situation the cell or entire partition will be reset. The data field contains the return stat…
1.3.6.1.4.1.11.2.23.35.9367NodehpevtBootMoveSlavesDispatcherAddrErrPDC is about to halt the cell because PDC was unable to determine the GNI address of the SlaveDispatcher function of PDC relocated to memory by PDC. The data f…
1.3.6.1.4.1.11.2.23.35.9368NodehpevtBootMoveSlavesCheckSlaveErrPDC is about to halt the cell because at least one of the processors didn't complete the task for which they were awakened and then return to sleep. The data f…
1.3.6.1.4.1.11.2.23.35.9370NodehpevtBootMoveSlavesFpSetAddrErrPDC is about to halt the cell because PDC was unable to determine the GNI address of the CpuFpSet() function of PDC relocated to memory by PDC. The data field …
1.3.6.1.4.1.11.2.23.35.9371NodehpevtBootMoveSlavesFpSetErrPDC is about to halt the cell because one or more of the slaves were unable to change their CPU FP state in PDH memory on the local cell. The data field contai…
1.3.6.1.4.1.11.2.23.35.9372NodehpevtBootMoveCellMonarchsStructAddrErrPDC was trying to move the cell monarchs on each of the non-core cells into the Dispatcher, but in order to do that, the PD monarch needs to be able to read th…
1.3.6.1.4.1.11.2.23.35.9373NodehpevtBootMoveCellMonarchsCheckSlaveErrPDC is about to reset the partition because at least one of the processors didn't complete the task for which they were awakened and then return to sleep. The …
1.3.6.1.4.1.11.2.23.35.9375NodehpevtBootMoveCellMonarchsFpSetAddrErrPDC is about to reset the partition because it is unable to determine the GNI address for the CpuFpSet() function for one or more of the cells in the partition…
1.3.6.1.4.1.11.2.23.35.9376NodehpevtBootMoveCellMonarchsFpSetErrPDC is about to reset the partition because one or more of the processors were unable to successfully modify their CPU FP State (aka their PST state). The data…
1.3.6.1.4.1.11.2.23.35.9379NodehpevtBootDualCoreInitFailMX2 initialization failed.
1.3.6.1.4.1.11.2.23.35.9380NodehpevtBootDeconfigCpuModulePairA cpu that is attached to a cpu that is slated for deconfiguration is being deconfigured as well.
1.3.6.1.4.1.11.2.23.35.9382NodehpevtBootVirtualizeDualCoreRegistersFailFW failed to virtualize the mx2 interposer.
1.3.6.1.4.1.11.2.23.35.9383NodehpevtBootVirtualizeDualCoreInterposerFailFW has failed to virtualize the mx2 interposer.
1.3.6.1.4.1.11.2.23.35.9385NodehpevtBootInstallPmiHandlerFailedInstallation of the FW PMI handler has failed.
1.3.6.1.4.1.11.2.23.35.9388NodehpevtPdhcCellIncompatableCell and or cpus have failed compatibility checks.
1.3.6.1.4.1.11.2.23.35.9389NodehpevtPdhcPdhNotAvailablePDH space not available after release from reset.
1.3.6.1.4.1.11.2.23.35.9390NodehpevtPdhcMponFailedMPON failed to release.
1.3.6.1.4.1.11.2.23.35.9391NodehpevtPdhcDillonResetFailedDillon failed to reset.
1.3.6.1.4.1.11.2.23.35.9392NodehpevtPdhcDmdClockFailedDMD clock is not running.
1.3.6.1.4.1.11.2.23.35.9394NodehpevtAllCpusDeconfOnCellAll possible CPUs on a cell have been scheduled for deconfiguration.
1.3.6.1.4.1.11.2.23.35.9403NodehpevtFabricLogRoutingRdErrA read error occurred while dumping the XBC port routing registers during boot. This cell will attempt fabricless boot. Data field: (XBC port << 48) | (XBC num…
1.3.6.1.4.1.11.2.23.35.9412NodehpevtFabricLinkRendezDisableErrAfter cell rendezvous for a 2 cell Medel, only one cell made it into the partition. Disabling the link failed. The cell will reset for reconfig. Data Field: re…
1.3.6.1.4.1.11.2.23.35.9417NodehpevtAcDeletedA0Power is no longer being supplied to input A0 on the cabinet specified in the data field.
1.3.6.1.4.1.11.2.23.35.9418NodehpevtAcDeletedA1Power is no longer being supplied to input A1 on the cabinet specified in the data field.
1.3.6.1.4.1.11.2.23.35.9419NodehpevtAcDeletedB0Power is no longer being supplied to input B0 on the cabinet specified in the data field.
1.3.6.1.4.1.11.2.23.35.9420NodehpevtAcDeletedB1Power is no longer being supplied to input B1 on the cabinet specified in the data field.
1.3.6.1.4.1.11.2.23.35.9428NodehpevtFabricCc2CcLinkDisableErrFailed to disable the XIN link init CSR on a XBCless system. Cell will halt. Data field: return status (0 = SUCCESS, -1 = FAILURE), -1 is expected for this eve…
1.3.6.1.4.1.11.2.23.35.9430NodehpevtFabricISREarlyCopyRoutingErrError writing the XBC port's routing registers. The cell will reboot. Data Field: XBC port << 44 | XBC num << 32 | return status
1.3.6.1.4.1.11.2.23.35.9431NodehpevtFabricClrLinkInitBitErrMaskRdCould not read the XIN error mask register on the CC. Data Field: cell number and return status
1.3.6.1.4.1.11.2.23.35.9432NodehpevtFabricClrLinkInitBitErrMaskWrCould not write the XIN error mask register on the CC. Data Field: cell number and return status
1.3.6.1.4.1.11.2.23.35.9433NodehpevtFabricPortPairRdPstatusErrWhile testing link traversability, a XBC CSR could not be read. Data Field: Port Number << 44 | XBC Number << 32 | return value
1.3.6.1.4.1.11.2.23.35.9438NodehpevtPdhBatteryPowerLowThe Battery-Low interrupt was signaled in the Interrupt Pending Register in Dillon (PDH) by the hardware. PDHC is merely reporting the problem.
1.3.6.1.4.1.11.2.23.35.9440NodehpevtNoHandoffToOsMcaThis means that the system FW MCA handler is not going to handoff to the OS_MCA handler.
1.3.6.1.4.1.11.2.23.35.9441NodehpevtBootRtnFromSwCantGetCountersWhen returning from other software, like when returning from ISL, PDC is trying to make sure that all of the slave processors in the partition are asleep; howe…
1.3.6.1.4.1.11.2.23.35.9442NodehpevtBootRtnFromSwCpuNotAsleepWhen returning to PDC from other software, like returning from ISL, PDC tries to verify that all the slave processors are in the expected state (i.e. that all …
1.3.6.1.4.1.11.2.23.35.9445NodehpevtBootDeconfigAbsentCantSetCpuStatePDC could not access one of its own data structures on the local cell. The cell will be halted. The data field contains the return status from the PDC function…
1.3.6.1.4.1.11.2.23.35.9448NodehpevtNvramBlockTableCorruptThe NVRAM-based descriptor for System Firmware NVRAM blocks is corrupt.
1.3.6.1.4.1.11.2.23.35.9450NodehpevtBootMoveSlavesSetTimeoutErrThe cell will be reset because it was unable to access PDH memory on its own cell. While trying to move all the slave processors on the cell to the 'late boot …
1.3.6.1.4.1.11.2.23.35.9460NodehpevtBootReconfigAllCpusAll CPUs have been determined to be manually deconfigured in NVM during boot. This may only happen when switching from single core CPU deconfiguration to multi…
1.3.6.1.4.1.11.2.23.35.9461NodehpevtBootGetNumcoresFailureA failure has occurred trying to determine the number of CPU cores per module. Depending upon the situation, either the cell will be halted or the entire parti…
1.3.6.1.4.1.11.2.23.35.9465NodehpevtFabricRmtRoutePortTopoErrWhile writing the remote routing, the local XBC could not be accessed to determine the topology. Look for additional chassis codes to determine what will happe…
1.3.6.1.4.1.11.2.23.35.9466NodehpevtFabricCellRerouteFailureFailed to route around a broken link on cell reboot. Data Field: PDC return status
1.3.6.1.4.1.11.2.23.35.9468NodehpevtFabricRdFailedLinksErrorCould not read the XBC register that contains the number of links that are currently broken on the complex. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9469NodehpevtFabricWrFailedLinksRdErrorCould not read the XBC register that contains the number of links that are currently broken on the complex. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9470NodehpevtFabricWrFailedLinksWrErrorCould not write the XBC register that contains the number of links that are currently broken on the complex. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9471NodehpevtFabricIncFailedLinksRdErrorCould not read the XBC register that contains the number of links that are currently broken on the complex. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9472NodehpevtFabricIncFailedLinksWrErrorCould not write the XBC register that contains the number of links that are currently broken on the complex. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9473NodehpevtFabricIncFailedLinksHitLimitToo many broken crossbar links were found. This cell will have no connectivity to other cells in the complex. It will attempt a fabricless boot, except in a fe…
1.3.6.1.4.1.11.2.23.35.9474NodehpevtFabricRtgCompleteRdFldLinksErrCould not read the XBC register that contains the number of links that are currently broken on the complex. Data Field: PDC return status
1.3.6.1.4.1.11.2.23.35.9475NodehpevtFabricRtgCompleteWrFldLinksErrCould not write the XBC register that contains the number of links that are currently broken on the complex. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9476NodehpevtFabricCellRerouteRdXbcErrCould not read the XBC register that marks the ports that have been routed around. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9477NodehpevtFabricCellRerouteNbrNotReachableThe PIOB route to the remote XBC was not traversable. The cell will halt. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9479NodehpevtFabricCellRerouteSm4RlsErrCould not release the remote XBC's semaphore. Cell will halt. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9480NodehpevtFabricRmtRoutePortBcastWrErrFailed to complete a broadcast write to an XBC. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9481NodehpevtFabricRmtRoutePortRdErrFailed to complete a read to the built-in port of a XBC. Data Field: (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9482NodehpevtFabricRmtRoutePortWrErrFailed to complete a write to the local cell's port of the XBC. Data Field: (XBC Port << 44) | (XBC Num << 32) | PDC return status
1.3.6.1.4.1.11.2.23.35.9484NodehpevtIoLinkSubsystemFailedThe link between the CC and SBA failed meaning that I/O is not available to the reporting cell.
1.3.6.1.4.1.11.2.23.35.9485NodehpevtIoSbaSubsystemFailedAn error was detected in the SBA and the reporting cell has no I/O.
1.3.6.1.4.1.11.2.23.35.9486NodehpevtIoErrengineErrorThe structured exception handling within the system firmware failed during I/O initialization.
1.3.6.1.4.1.11.2.23.35.9487NodehpevtIoDiscEeMallocErrThere is not enough malloc resources for the I/O structure exception handling. I/O on the reported cell is not available.
1.3.6.1.4.1.11.2.23.35.9488NodehpevtIoDiscEeCreatetreeErrError creating the structure for housing the I/O structured exception handling services and data. I/O is lost on the reporting cell.
1.3.6.1.4.1.11.2.23.35.9489NodehpevtIoDiscEeAttachserviceErrUnable to bind the I/O structure exception handling to the internal data structures.
1.3.6.1.4.1.11.2.23.35.9490NodehpevtIoDiscEeInitErrError detected while initializing the I/O structure exception handling services.
1.3.6.1.4.1.11.2.23.35.9491NodehpevtIoDiscEeInitializationErrError initializing the I/O structure exception handling data structures.
1.3.6.1.4.1.11.2.23.35.9492NodehpevtIoDiscEeContextErrThe structured I/O exception handling data structures have an error. All I/O on the reporting cell is not available.
1.3.6.1.4.1.11.2.23.35.9493NodehpevtIoDiscCreateSbaNodeErrWhile setting up the internal SBA data and service an error was detected. All I/O for the reporting cell is not available.
1.3.6.1.4.1.11.2.23.35.9494NodehpevtIoDiscSbaAttachserviceErrAn error attaching firmware services to the internal structures was detected. All I/O on the reporting cell is not available.
1.3.6.1.4.1.11.2.23.35.9495NodehpevtIoDiscSbaInitnodeErrSystem firmware detected an error initializing internal SBA data structures and services. This is usually an error with unavailable resources.
1.3.6.1.4.1.11.2.23.35.9496NodehpevtIoDiscSbaUnknownErrThe SBA type is unknown to the system firmware. The I/O on the reporting cell is not available.
1.3.6.1.4.1.11.2.23.35.9497NodehpevtIoDeviceMissingAn expected I/O device cannot be detected by the system firmware.
1.3.6.1.4.1.11.2.23.35.9498NodehpevtFabricRmtRoutePortBadRerouteToo many broken links! The XBC port route around failed because the route-around port was bad too. Data field: (XBC port << 44) | (XBC num << 32) | port state
1.3.6.1.4.1.11.2.23.35.9652NodehpevtAgtPredictMemFailECC (Error Checking and Correcting) memory is designed to detect and correct single-bit errors that occasionally occur in computer systems. This memory module …
1.3.6.1.4.1.11.2.23.35.9653NodehpevtWinAgtLockedPropertyServer Agents SNMP branch is not responding due to a portion of the IPMI Management Subsystem being locked by another entity.
1.3.6.1.4.1.11.2.23.35.9658NodehpevtIoPciPowerOverloadErrA non-hot plug I/O slot's power consumption increases the total I/O power consumption beyond the supported limit. Firmware will display the following EFI error…
1.3.6.1.4.1.11.2.23.35.9659NodehpevtMemSbeSeedingEnabledThis is a warning that the system is running in a degraded mode. It will only be emitted in MFG mode when Memory SBE Seeding is enabled. This is only for testi…
1.3.6.1.4.1.11.2.23.35.9661NodehpevtFabricWrFailedLinksTopoErrRead failure while writing the number of failed links to the XBC. Data Field: Return Status (SUCCESS = 0, FAILURE = -1)
1.3.6.1.4.1.11.2.23.35.9663NodehpevtBootErrInitGroupCPaFieldsPDC could not access a complex profile. The partition will be reset because the available complex profile is not valid. Data field contains the return status f…
1.3.6.1.4.1.11.2.23.35.9666NodehpevtFabricAssertFabricHopAn unexpected error occurred while initializing the fabric. The firmware is not able to analyze this error. Clues to the cause of this error may be found in th…
1.3.6.1.4.1.11.2.23.35.9668NodehpevtBootFailedReadingProfileCInIcmPDC could not access a complex profile. The partition will be reset. Data field contains the return status from the function that encountered the error.
1.3.6.1.4.1.11.2.23.35.9670NodehpevtFabricHaltLinkDisableErrBefore attempting a fabricless boot, the cell's link to the fabric should be disabled to provide isolation and stability. The link could not be disabled, so th…
1.3.6.1.4.1.11.2.23.35.9674NodehpevtBootGetSpiromGetSiblingErrConfiguration information on the processor was invalid. The cell will be halted. Data field contains the return value from the function that encountered the er…
1.3.6.1.4.1.11.2.23.35.9678NodehpevtCpuClockRatioMismatchThe clock ratio that the processor is running at does not match the clock ratio that manageability is reporting.
1.3.6.1.4.1.11.2.23.35.9681NodehpevtBootStopBootOverrideThe user has manually bypassed a stop boot condition (caused by an error during boot) and continued to boot an O/S. The system might experience unpredictable f…
1.3.6.1.4.1.11.2.23.35.9682NodehpevtVgaBiosRelocFailFirmware was unable to relocate the VGA BIOS to the hardcoded VGA BIOS region in main memory (physical address range 0xc0000 - 0xdffff). VGA routing has been d…
1.3.6.1.4.1.11.2.23.35.9685NodehpevtCompMatrixXsumErrorThe component compatibility matrix stored in NVRAM and used by system firmware has a checksum error. The stored value does not equal the calculated value. The …
1.3.6.1.4.1.11.2.23.35.9695NodehpevtBootGetDefaultRdrsFailedPDC could not read an internal CPU register. The partition will be reset. Data field is the return status from the function that encountered the error.
1.3.6.1.4.1.11.2.23.35.9696NodehpevtBootGetCurrentRdrsFailedPDC could not read an internal CPU register. The partition will be reset. Data field is the return status from the function that encountered the error.
1.3.6.1.4.1.11.2.23.35.9697NodehpevtBootReadPrefetchFailedPDC failed reading a value out of its own copy of the internal CPU register settings. Data field is a status return indicating the type of failure.
1.3.6.1.4.1.11.2.23.35.9698NodehpevtBootReadZlcoFailedPDC failed reading a value out of its own copy of the internal CPU register settings. Data field is a status return indicating the type of failure.
1.3.6.1.4.1.11.2.23.35.9700NodehpevtBootUpdateZlcoAndPrefetchFailedPDC attempted to update CPU registers to match their respective settings in the complex profile, but a failure was returned from the call to accomplish the upd…
1.3.6.1.4.1.11.2.23.35.9701NodehpevtBootErrorReadingZlcoFlagInPdProfilePDC could not access a complex profile. The partition will be reset.. Data field contains the return status from the function that encountered the error.
1.3.6.1.4.1.11.2.23.35.9706NodehpevtBootFindCoreCellCmplxProfileAcErrPDC could not access a complex profile. The cell will be reset. Data field contains the return status from the function that encountered the error.
1.3.6.1.4.1.11.2.23.35.9707NodehpevtBootFindCoreCellConfigSelectErrCould not find a potential core cell for the partition in the configured set. This cell will reset for reconfiguration. Data Field: return status from failing …
1.3.6.1.4.1.11.2.23.35.9708NodehpevtBootCellLclCantFindViableThe potential core cell was not viable (i.e. no core I/O, etc). This cell will reset for reconfiguration. Data Field: bit mask of cells that made the rendezvou…
1.3.6.1.4.1.11.2.23.35.9709NodehpevtBootCellRmtCantFindViableThe potential core cell was not viable (i.e. no core I/O, etc). This cell will reset for reconfiguration. Data Field: bit mask of cells that made the rendezvou…
1.3.6.1.4.1.11.2.23.35.9710NodehpevtBootFindCoreCellNotInRendezThe potential core cell did not rendezvous with the rest of the partition. This cell cannot talk to the selected core cell. This cell will reset for reconfigur…
1.3.6.1.4.1.11.2.23.35.9711NodehpevtBootFindCoreCellLclNotViableThe local cell is disconnected from the rest of the system due to the main backplane configuration. While the partition is only configured to contain a single …
1.3.6.1.4.1.11.2.23.35.9712NodehpevtBootFindCoreCellFabriclessPdErrThis cell has booted without the main backplane, probably due to prior main backplane errors. The partition it is in is configured with 3 or more cells. The co…
1.3.6.1.4.1.11.2.23.35.9719NodehpevtRtcAccessErrorWhile validating the internal RTC data the data is read twice and compared. If the comparison fails to match the read is performed again up a maximum of 50 tim…
1.3.6.1.4.1.11.2.23.35.9727NodehpevtBootAccessCellArchErrPDC attempts to make sure that all of the cells in a partition are installed in the same processor architecture. PDC failed to read the architecture for anothe…
1.3.6.1.4.1.11.2.23.35.9740NodehpevtXbcLogSizeErrThe buffer size passed in to the XBC error logging routine through SAL_GET_STATE_INFO, SAL_CLEAR_STATE_INFO, or MCA logging is too small for the XBC error log …
1.3.6.1.4.1.11.2.23.35.9741NodehpevtXbcLogClearErrSystem firmware was unable to clear an XBC error. The data field contains: XBC number (32:43) port number (44:55) error type (0:31)
1.3.6.1.4.1.11.2.23.35.9744NodehpevtIodiscPciLogErrorError encountered while collecting PCI error logs. The result is some or all PCI error logs will be unavailable.
1.3.6.1.4.1.11.2.23.35.9745NodehpevtIodiscSbaLogErrorError encountered while collecting SBA error logs. The result is some or all SBA error logs will be unavailable.
1.3.6.1.4.1.11.2.23.35.9746NodehpevtXbcInitMaxRetriesDuring fabric initialization, if a crossbar is found to be in an unexpected state, the number of retries is incremented. If the number of retries exceeds the m…
1.3.6.1.4.1.11.2.23.35.9750NodehpevtWinAgtPredictMemFailWarningECC (Error Checking and Correcting) memory is designed to detect and correct single-bit errors that occasionally occur in computer systems. This memory module …
1.3.6.1.4.1.11.2.23.35.9751NodehpevtWinAgtPredictMemFailCriticalECC (Error Checking and Correcting) memory is designed to detect and correct single-bit errors that occasionally occur in computer systems. This memory module …
1.3.6.1.4.1.11.2.23.35.9753NodehpevtPciFatalRopeParityErrA error occurred on the bus connecting the PCI card to the system bus.
1.3.6.1.4.1.11.2.23.35.9754NodehpevtPciFatalBusErrorA PCI card has been marked as 'fatal' by the operating system due to a bus error. The LBA has been isolated by the operating system due to an error which occur…
1.3.6.1.4.1.11.2.23.35.9755NodehpevtPciFatalDeviceErrorA PCI card has been marked as 'fatal' by the operating system due to a device error.
1.3.6.1.4.1.11.2.23.35.9768NodehpevtBootErrorReadingFirstBootTokenFirmware tried to read the first boot token an got a failure. The data field contains the token number that FW tried to read. This is a stop boot condition
1.3.6.1.4.1.11.2.23.35.9769NodehpevtBootNonPaCellDetectedmonarch PA cell has detected that a cell it is attempting to rendezvous into its PD is not a PA cell and is thus incompatible.
1.3.6.1.4.1.11.2.23.35.9774NodehpevtFabricErrorsXbcClearWrErrA XBC error could not be cleared due to a write failure. The data field indicates the type of error: (XBC Port Num << 56) | (XBC Num << 32) | error status
1.3.6.1.4.1.11.2.23.35.9775NodehpevtFabricErrorsXbcClearRdGlblErrFailed to read the XBC Global CSR Error Status register. Data Field: (XBC Port Num << 56) | (XBC Num << 32) | error status
1.3.6.1.4.1.11.2.23.35.9776NodehpevtFabricErrorsXbcClrLoSevErrThe XBC CSR Low Severity error was not cleared or more errors remain. Data Field: (XBC Port Num << 56) | (XBC Num << 32) | contents of the XBC CSR Error Status…
1.3.6.1.4.1.11.2.23.35.9777NodehpevtFabricErrorsXbcClrHiSevErrThe XBC CSR High Severity error was not cleared or more errors remain. Data Field: (XBC Port Num << 56) | (XBC Num << 32) | contents of the XBC CSR Error Statu…
1.3.6.1.4.1.11.2.23.35.9778NodehpevtFabricErrorsXbcClearRdPortErrFailed to read the XBC Port Error Status register. Data Field: (XBC Port Num << 56) | (XBC Num << 32) | error status
1.3.6.1.4.1.11.2.23.35.9780NodehpevtFabricErrsCsrLogClrRdSlicesErrFailed to read the XBC Global CSR Error Status register. Data Field: (XBC Port Num << 56) | error status
1.3.6.1.4.1.11.2.23.35.9781NodehpevtFabricErrsCsrLogClrCopyBlk0ErrFirmware failed to copy the XBC CSR Error symbol 01 registers into a data structure on the stack. Data Field: address where the register contents are being cop…
1.3.6.1.4.1.11.2.23.35.9782NodehpevtFabricErrsCsrLogClrCopyBlk2ErrFirmware failed to copy the XBC CSR Error symbol 23 registers into a data structure on the stack. Data Field: address where the register contents are being cop…
1.3.6.1.4.1.11.2.23.35.9783NodehpevtFabricXbcLoStateResetErrFirmware was unable to reset the XBC CSR Low Severity error log state. Data Field: (XBC Port Num << 56) | (XBC Num << 32) | error status
1.3.6.1.4.1.11.2.23.35.9784NodehpevtFabricClrXbcSym01FailureThe XBC Low Severity error logs were not cleared. Data Field: (XBC Port Num << 56) | (XBC Num << 32) | number of failed clear attempts
1.3.6.1.4.1.11.2.23.35.9785NodehpevtFabricClrXbcIsLoCsrErrErrReading the XBC CSR Error Status register failed. Data field: (XBC Port Num << 56) | (XBC Num << 32) | error status
1.3.6.1.4.1.11.2.23.35.9786NodehpevtFabricClrXbcRdLoLogStateErrFailed to read a XBC Global scratch register that indicates if new, unlogged errors have been encountered. Data field: (XBC Port Num << 56) | (XBC Num << 32) |…
1.3.6.1.4.1.11.2.23.35.9787NodehpevtFabricXbcHiStateResetErrFirmware was unable to reset the XBC CSR Low Severity error log state. Data Field: (XBC Port Num << 56) | (XBC Num << 32) | error status
1.3.6.1.4.1.11.2.23.35.9788NodehpevtFabricClrXbcIsHiCsrErrErrReading the XBC CSR Error Status register failed. Data field: (XBC Port Num << 56) | (XBC Num << 32) | error status
1.3.6.1.4.1.11.2.23.35.9789NodehpevtFabricClrXbcRdHiLogStateErrFailed to read a XBC Global scratch register that indicates if new, unlogged errors have been encountered. Data field: (XBC Port Num << 56) | (XBC Num << 32) |…
1.3.6.1.4.1.11.2.23.35.9801NodehpevtPlatformCacheHashingErrorAn error occurred while enabling hashing in the platform cache. The data field contains the status.
1.3.6.1.4.1.11.2.23.35.9827NodehpevtFabricXbcWriteableInvalidCsrA write to an invalid XBC CSR address was attempted. The write will not be allowed. The severity of this result will be determined by the calling function. Dat…
1.3.6.1.4.1.11.2.23.35.9832NodehpevtMcCellsLostConnectionIt indicates loss of cell connectivity in the partition during a global MCA processing.
1.3.6.1.4.1.11.2.23.35.9849NodehpevtBuildErrCellDevTreeError status of building the cell-level firmware device tree
1.3.6.1.4.1.11.2.23.35.9867NodehpevtDcnfgFsbInitAn error has occurred during CPU FSB interface initialization. The datafield contains a 32-bit error number and 32-bits of additional error information. The CP…
1.3.6.1.4.1.11.2.23.35.9868NodehpevtDcnfgCpuParamsAn error has occurred while obtaining CPU parameters from the CPU abstraction layer. The datafield contains a 32-bit error number and 32-bits of additional err…
1.3.6.1.4.1.11.2.23.35.9869NodehpevtDcnfgCpuIcacheAn error occurred while getting CPU icache parameters from the CPU abstraction layer. The datafield contains a 32-bit error number and 32-bits of additional er…
1.3.6.1.4.1.11.2.23.35.9870NodehpevtDcnfgCpuDcacheAn error occurred while obtaining CPU dcache parameters from the CPU abstraction layer. The datafield contains a 32-bit error number and 32-bits of additional …
1.3.6.1.4.1.11.2.23.35.9871NodehpevtDcnfgCpuCacheStateAn error occurred while initializing the CPU cache to a known state. The datafield contains a 32-bit error number and 32-bits of additional error information. …
1.3.6.1.4.1.11.2.23.35.9872NodehpevtDcnfgCpuCacheMonitorAn error occurred while enabling CPU cache error monitoring. The datafield contains a 32-bit error number and 32-bits of additional error information. The CPU …
1.3.6.1.4.1.11.2.23.35.9873NodehpevtDcnfgCpuMcaAn error occurred while enabling some machine error check traps on a CPU. The datafield contains a 32-bit error number and 32-bits of additional error informat…
1.3.6.1.4.1.11.2.23.35.9874NodehpevtDcnfgCpuDisableMcaAn error occurred while disabling marching error check traps on a CPU. The datafield contains a 32-bit error number and 32-bits of additional error information…
1.3.6.1.4.1.11.2.23.35.9875NodehpevtDcnfgCpuSelfTestAn error occurred during the serialized CPU late selftests. The datafield contains a 32-bit error number and 32-bits of additional error information. The CPU w…
1.3.6.1.4.1.11.2.23.35.9876NodehpevtDcnfgCpuL2CacheAn error occurred while enabling the CPU L2 shared cache. The datafield contains a 32-bit error number and 32-bits of additional error information. The CPU wil…
1.3.6.1.4.1.11.2.23.35.9877NodehpevtDcnfgCpuDefValueAn error while getting default values for programmable CPU internal registers from the CPU abstraction layer. The datafield contains a 32-bit error number and …
1.3.6.1.4.1.11.2.23.35.9878NodehpevtDcnfgCpuInRegAn error occurred while getting an address for a CPU internal register within a buffer from the CPU abstraction layer. The datafield contains a 32-bit error nu…
1.3.6.1.4.1.11.2.23.35.9879NodehpevtDcnfgCpuProgRegAn error occurred while programming CPU internal registers with final configuration values. The datafield contains a 32-bit error number and 32-bits of additio…
1.3.6.1.4.1.11.2.23.35.9896NodehpevtNoMemSelfTestThere was not enough error free memory in the system to run the late selftests.
1.3.6.1.4.1.11.2.23.35.10060NodehpevtCellLatchOpenThe left cell ejector on the specified cell is open.
1.3.6.1.4.1.11.2.23.35.10061NodehpevtDcnfgRightCellLatchThe right ejector latch on the specified cell board is open.
1.3.6.1.4.1.11.2.23.35.10062NodehpevtCellLatchSensorBadThe optical emitters on the cell latch sensors are not functioning.
1.3.6.1.4.1.11.2.23.35.10063NodehpevtVrmVltFaultThe specified vrm is reporting a fault.
1.3.6.1.4.1.11.2.23.35.10064NodehpevtVrmTempFltThe specified vrm is reporting a fault.
1.3.6.1.4.1.11.2.23.35.10065NodehpevtVrmFltThe specified rail is reporting a fault.
1.3.6.1.4.1.11.2.23.35.10068NodehpevtVrmIoVltFltThe specified pci vrm is reporting a voltage fault.
1.3.6.1.4.1.11.2.23.35.10069NodehpevtPwrBrickVltFltThe specified pci power brick is reporting a voltage fault.
1.3.6.1.4.1.11.2.23.35.10070NodehpevtVrmBkPlaneTempFltThe specified vrm is reporting a temperature fault.
1.3.6.1.4.1.11.2.23.35.10071NodehpevtBkPlanePwrBrickTempFltThe specified pci power brick is reporting a temperature fault.
1.3.6.1.4.1.11.2.23.35.10072NodehpevtBkPlanVrmRailFltThe specified vrm rail is reporting a fault.
1.3.6.1.4.1.11.2.23.35.10073NodehpevtBkPlanePwrBrkFltThe specified pci brick is reporting a fault.
1.3.6.1.4.1.11.2.23.35.10103NodehpevtBkPlaneVrmVltFltThe specified system backplane vrm is reporting a module voltage fault.
1.3.6.1.4.1.11.2.23.35.10104NodehpevtBkPlaneVrmTempFltThe specified system backplane vrm is reporting a temperature fault.
1.3.6.1.4.1.11.2.23.35.10105NodehpevtBkPlaneFltThe specified system backplane rail is reporting a fault
1.3.6.1.4.1.11.2.23.35.10115NodehpevtMstrMpFailedThe master mp has failed. The slave has taken over management of the cabinet.
1.3.6.1.4.1.11.2.23.35.10116NodehpevtNvramAllocThe NVRAM service was unable to satisfy an NVRAM allocation request.
1.3.6.1.4.1.11.2.23.35.10132NodehpevtRtcTimeRegThe RTC seems to not be updating its internal time registers. The cell cannot boot without the RTC.
1.3.6.1.4.1.11.2.23.35.10159NodehpevtPAAFltMx2An uncorrectable Power Aware Architecture (PAA) fault has occurred on the MX2 module and PAA firmware has halted. The system will continue to run without PAA f…
1.3.6.1.4.1.11.2.23.35.10209NodehpevtAPIopenLnkLocCellfabric API is about to open the a link going out of the local cell
1.3.6.1.4.1.11.2.23.35.10272NodehpevtCSRreadUnsuccessTimeOutAn Arches fabric CSR read was unsuccessful because of a timeout.
1.3.6.1.4.1.11.2.23.35.10273NodehpevtCSRWriteUnsuccessAn Arches fabric CSR write was unsuccessful
1.3.6.1.4.1.11.2.23.35.10343NodehpevtDataErrEncountThe event data details the error return status from Phase3BackToBackPrep. Internal debug only, this refers to an unexpected firmware error or data corruption.
1.3.6.1.4.1.11.2.23.35.10351NodehpevtConfigMaxMemoryThe maximum memory supported by this system has been exceeded. The data field contains the amount of memory supported by the system.
1.3.6.1.4.1.11.2.23.35.10357NodehpevtFailDelBadPortFailed to delete a bad port while routing the fabric. Data field indicates return status
1.3.6.1.4.1.11.2.23.35.10358NodehpevtFailDelBadEdgefailed to delete an edge that was found to be bad during routing
1.3.6.1.4.1.11.2.23.35.10361NodehpevtCommandMemBufA command to the memory buffer chip failed to complete.
1.3.6.1.4.1.11.2.23.35.10375NodehpevtUnsupprtArflsCsrRouteTravsbleThe Arches Fabric function ArfIsCsrRouteTraversable was called for a back-to-back system. This is unsupported, ArfIsCsrRouteTraversable should only be called f…
1.3.6.1.4.1.11.2.23.35.10376NodehpevtInvalidPortToTravsbleAn invalid port number was given as an input to an Arches Fabric Traversability function. The port is expected to be an internal XBC num (8-15), but the actual…
1.3.6.1.4.1.11.2.23.35.10377NodehpevtUnbleRdXBCPortNghbrUnable to read XBC port neighbor information. Data field: (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10378NodehpevtXBCPortUnexpctNghbrChipXBC port with an unexpected neighbor chip type. Data field: (expected chip type) | (actual chip type << 16) | (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10379NodehpevtXBCPortHaveUnxpctNghbrIDAn XBC port was found to have an unexpected neighbor ID. Data field: (expected NID) | (actual NID << 16) | (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10380NodehpevtXBCHaveUnexpctNghbrPrtConnAn XBC was found to have an unexpected neighbor port connection. Data field: (expected port) | (actual port << 16) | (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10381NodehpevtDataNotFndEdgLstThe expected data was not found in the Arches Fabric expected edge list. Data field is unused
1.3.6.1.4.1.11.2.23.35.10382NodehpevtXBCPrtUnxpctNgbrChipAn XBC port has an unexpected neighbor chip type. Data field: neighbor type found, bits [7:0], other bits unused
1.3.6.1.4.1.11.2.23.35.10384NodehpevtXBCtoXBCLnkDwnA previously good XBC-XBC link was found to be down. Data field: (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10385NodehpevtXBCprtFndErrTravsblAn XBC port was found to have a Fatal Error during traversability test. Data field: (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10386NodehpevtUnblRdLnkCelFabCSRUnable to read the local cell's LINK_SEL_FABRIC CSR Data field: unused
1.3.6.1.4.1.11.2.23.35.10387NodehpevtUblRdXBCrouteTblUnable to read the XBC route table. Data field: (route index) | (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10388NodehpevtXBCLnkNotConnCSRTravsblAn XBC link was found to be not connected while testing CSR traffic traversability. Data field: (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10389NodehpevtErrRdAlrecAlbIdCsrError reading Skyline ALREC_ALB_ID CSR Data field: (Skyline port) | (Cell number << 56)
1.3.6.1.4.1.11.2.23.35.10390NodehpevtCirRoutFndTstXbcCsrA circular route was found while testing XBC CSR traffic traversability. Data field: (target XBC << 32) | (cellNum << 56)
1.3.6.1.4.1.11.2.23.35.10391NodehpevtXBCRdErrAlrecAlbIdCsrError reading ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10392NodehpevtXBC-XBCPrtHavInvldChipCnnAn XBC-XBC port had an invalid chip type connection. Data field: (expected chip type) | (actual chip type << 32)
1.3.6.1.4.1.11.2.23.35.10393NodehpevtArflsXbcRotTravrsblCalBakToBakArfIsXbcRouteTraversable was called on a back-to-back system which is an improper use of the function. Data field: unused
1.3.6.1.4.1.11.2.23.35.10394NodehpevtXBCToXBClnkFndFatErrIn ArfIsXbcRouteTraversable, an XBC-XBC link was found to have fatal errors. Data field: (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10395NodehpevtUnablRdXbcRotTblEnblMskCsrUnable to read the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10396NodehpevtErrRdXbcRotTablCsrError reading an XBC ROUTE_TABLE CSR. Data field: route index | (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10397NodehpevtXbcPrtErrRdAlrecAlbIDCsrError reading ALB ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10398NodehpevtXbcPrtFndUnxpctNgbrChipAn XBC port was found with an unexpected neighbor chip. Data field: expected chip type | (actual chip type << 32)
1.3.6.1.4.1.11.2.23.35.10401NodehpevtCelPrtPairNotFndGrphDatA cell/port pair was not found in the expected graph data. Data field: (cellNum << 32) | CC portNum
1.3.6.1.4.1.11.2.23.35.10402NodehpevtArchFabFndLocCelLnkNotConnArches Fabric Traversability code unexpectedly found the local cell link not connected. Data field: linkState (0 = connected, 1 = link pending, 2 = not connect…
1.3.6.1.4.1.11.2.23.35.10403NodehpevtXbcErrRdRoutCsrError reading the ROUTEx CSR on the XBC. Data field: route index | (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10404NodehpevtXbcUnablRdAlrecAlbIdCsrUnable to read the ALB ALREC_ALB_ID CSR for an XBC port. Data field: (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10405NodehpevtXbcPrtHasUnxpctNgbrChptypeAn XBC port has an unexpected neighbor chip type. Data field: expected neighbor chip type | (actual neighbor chip type << 32)
1.3.6.1.4.1.11.2.23.35.10406NodehpevtCelToCelLnkHasUnxpctNgbrChpTypeA Cell-Cell link has an unexpected neighbor chip type. Data field: expected neighbor chip type | (actual neighbor chip type << 32)
1.3.6.1.4.1.11.2.23.35.10407NodehpevtCelPrtPairNotExstGrphDatThe cell/port pair does not exist in the Arches Fabric expected graph data. Data field: CC port | (cellNum << 32)
1.3.6.1.4.1.11.2.23.35.10408NodehpevtCelToCelLnkConnUnxpctNgbrPrtA Cell-Cell link is connected to an unexpected neighbor port. Data field: expected neighbor port | (actual neighbor port << 32)
1.3.6.1.4.1.11.2.23.35.10409NodehpevtCelToCelLnkConnUnxpctCelA Cell-Cell link is connected to an unexpected cell. Data field: expected neighbor ID | (actual neighbor ID << 16) | (target cell << 32) | (local cell << 48)
1.3.6.1.4.1.11.2.23.35.10412NodehpevtEFIDrvrFailLoadAn EFI Driver may be corrupt.
1.3.6.1.4.1.11.2.23.35.10413NodehpevtVmRetErrNonCohTblVM_FindAllRoutes returned an unexpected error during Non-Coherent table setup. Data field: (return value) | (source cell << 32) | (target cell << 48)
1.3.6.1.4.1.11.2.23.35.10414NodehpevtNctTblWrtGlobLnkSelNonCohFailIn SetupNCTable, a write to the GLOBAL_LINK_SEL_NONCOH CSR failed. Data field: (data written to CSR) | (actual CSR data read << 32)
1.3.6.1.4.1.11.2.23.35.10415NodehpevtNctTblFailArfPhs3SetupNCTable failed in ArfPhase3. Data field: cell set passed in to SetupNCTable
1.3.6.1.4.1.11.2.23.35.10427NodehpevtPostRndevzFailPrepBckToBckSysA failure occurred while prepping a back-to-back system for post-rendezvous Arches Fabric setup. Data field: return value from Phase4BackToBackPrep
1.3.6.1.4.1.11.2.23.35.10429NodehpevtArfPhs4UnablSetNonCohLnkArfPhase4 was unable to set up the Non-Coherent link select to at least one cell in its alive/gsm sharing set. Data field: bitmap of unreachable cells
1.3.6.1.4.1.11.2.23.35.10431NodehpevtUnablSetNonCohRoutUnable to set the Non-Coherent route. Data field: (sourceCell << 32) | (cell set passed in to SetupNCTable)
1.3.6.1.4.1.11.2.23.35.10432NodehpevtUnableSetCohRoutCelUnable to setup the Coherent route table for a cell in our partition. Data field: (sourceCell << 32) | (cell set passed in to SetupCohTable)
1.3.6.1.4.1.11.2.23.35.10435NodehpevtErrWrtXbcRoutTblEnblMskCsrError writing the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (route set to disable) | (xbcNum << 32) | (xbc port << 48)
1.3.6.1.4.1.11.2.23.35.10436NodehpevtVertxRetUnxpctErrNonCohTblThe Arches Fabric vertex module returned an unexpected error during Non-Coherent table setup. Data field: (return value) | (sourceCell << 32) | (dest cell << 4…
1.3.6.1.4.1.11.2.23.35.10439NodehpevtWrtSkyGlobLnkSelCohFailA write to a Skyline Global LINK_SEL_COHx CSR failed. Data field: cell number of the Skyline that failed, bits [7:0]. Other bits unused
1.3.6.1.4.1.11.2.23.35.10475NodehpevtUnablWrtXbcPrtCsrUnable to write the XBC port scratch CSR with the routing state. Data field: (routing state) | (xbcNum << 32) | (portNum << 48)
1.3.6.1.4.1.11.2.23.35.10481NodehpevtSysFwUnAccesComplxProfCouldn't get the configured set during Fabric Init
1.3.6.1.4.1.11.2.23.35.10482NodehpevtSysFwDetctErrFabInitError while running the Arches Fabric API part of Fabric Init.
1.3.6.1.4.1.11.2.23.35.10483NodehpevtSysFwDetctFailFabInitFailure while running the Fabric API part of Fabric Init.
1.3.6.1.4.1.11.2.23.35.10487NodehpevtSysFwDetctErrFabOptimzAn error was encountered while running the Fabric API to optimize the fabric.
1.3.6.1.4.1.11.2.23.35.10489NodehpevtInPwrUPSFailInput power to the specified UPS has failed.
1.3.6.1.4.1.11.2.23.35.10490NodehpevtUpsRestoredInput power to the specified UPS has been restored.
1.3.6.1.4.1.11.2.23.35.10495NodehpevtUpsExhaustedThe system is being powered down as UPS power is exhausted.
1.3.6.1.4.1.11.2.23.35.10509NodehpevtSALFailRedzvsProcsDuring SAL Machine Check handling, SAL fail to round up all the processor entering SAL Machine check handler.
1.3.6.1.4.1.11.2.23.35.10510NodehpevtSALFailClrCECLogSal failed to clear the CEC logs during Machine check handling. The data field return an ASCII name of the CEC that failed to clear.
1.3.6.1.4.1.11.2.23.35.10516NodehpevtSysFwUnAccesXBCSemphrAn error occurred while getting the XBC semaphore.
1.3.6.1.4.1.11.2.23.35.10518NodehpevtSysFwDetctErrRelXBCGlobSemphrAn error occurred while releasing the XBC Global Semaphore.
1.3.6.1.4.1.11.2.23.35.10519NodehpevtSysFwDetctErrOwnXBCGlobSemphrAn error occurred while checking the owner of the XBC Global Semaphore.
1.3.6.1.4.1.11.2.23.35.10520NodehpevtErrFormXbcSemphrAddrAn error occurred while forming the XBC semaphore address. Data Field: (xbc << 32) | (cell << 56)
1.3.6.1.4.1.11.2.23.35.10521NodehpevtErrRdXbcGlobSemphrError reading the XBC Global Semaphore. Data Field: (cell num << 56) | (xbc << 32)
1.3.6.1.4.1.11.2.23.35.10523NodehpevtFailGetXbcGlobSemphrAddrFailure to get the XBC Global Semaphore address. Data Field: (cell num << 56) | (xbc << 32)
1.3.6.1.4.1.11.2.23.35.10524NodehpevtFailWrtXbcGlobSemphrFailed to write the XBC Global Semaphore. Data Field: (cell num << 56) | (xbc << 32)
1.3.6.1.4.1.11.2.23.35.10528NodehpevtFailRdXbcGlobSemphrFailed to read the XBC Global Semaphore. Data Field: (cell num << 56) | (xbc << 32)
1.3.6.1.4.1.11.2.23.35.10529NodehpevtFailGetAddrXbcGlobSemphrFailed to get the address of the XBC Global Semaphore. Data Field: (cell num << 56) | (xbc << 32)
1.3.6.1.4.1.11.2.23.35.10530NodehpevtFailWrtXbcGlobSemphrAfrRlsFailed to write the XBC Global Semaphore. Data Field: (cell num << 56) | (xbc << 32)
1.3.6.1.4.1.11.2.23.35.10532NodehpevtFailRelXbcGlobSemphrFailed to release the XBC Global Semaphore. Data Field: (cell num << 56) | (xbc << 32)
1.3.6.1.4.1.11.2.23.35.10534NodehpevtFabPhsExeInvlOrdrFabric phases have been executed in an invalid order
1.3.6.1.4.1.11.2.23.35.10535NodehpevtFabPhsExeInvlOrdrDatExpctPhsFabric phases have been executed in an invalid order. Data field indicates the expected phase.
1.3.6.1.4.1.11.2.23.35.10558NodehpevtFailGetAddrXbcToXbcLnkFailed to get an address when opening XBC to XBC links. Data field is return value from GetAlbAddrBlk function. Internal debug only.
1.3.6.1.4.1.11.2.23.35.10559NodehpevtFailOpnFabLnkFailed to open a fabric link. Data field: [31:0] - error status from OpenFabricLink [39:32] - XBC ID [51:44] - XBC port number
1.3.6.1.4.1.11.2.23.35.10560NodehpevtErrWrtXbcRetRoutError when writing the XBC return route. Data field: [31:0] - error status from WriteRouteReg [39:32] - XBC ID [51:44] - XBC port number
1.3.6.1.4.1.11.2.23.35.10561NodehpevtErrEnblXbcRetRoutError enabling the XBC return route. Data field: [31:0] - error status from WriteRouteEnable [39:32] - XBC ID [51:44] - XBC port number
1.3.6.1.4.1.11.2.23.35.10564NodehpevtFailDisprsRoutAcrssLnkfailed to disperse the routes across links. Data field: [31:0] - error status from GetDispersedOutboundPort [39:32] - XBC ID [51:44] - XBC port number
1.3.6.1.4.1.11.2.23.35.10565NodehpevtErrSetXbcToXbcLnkRoutXError setting up XBC-XBC link for routing across it. Data field: [31:0] - error status from SetupXbcToXbcLinks [39:32] - XBC ID [51:44] - XBC port number
1.3.6.1.4.1.11.2.23.35.10566NodehpevtErrRoutRemtsideError while routing the remote side of a route. Data field: [31:0] - error status from RouteRemoteXbcPort [39:32] - XBC ID [51:44] - XBC port number [59:52] - …
1.3.6.1.4.1.11.2.23.35.10567NodehpevtErrGetAddrRoutRemtXbcError getting address while routing the remote XBC. Data field: [31:0] - error status from GetAlbAddrBlk [39:32] - XBC ID [51:44] - XBC port number
1.3.6.1.4.1.11.2.23.35.10568NodehpevtErrGetNgbrInfoError getting the neighbor info. Data field: [31:0] - error status from AlbGetNeighborInfo [39:32] - XBC ID [51:44] - XBC port number
1.3.6.1.4.1.11.2.23.35.10569NodehpevtErrFindShrtRoutError finding the shortest route. Most likely a firmware error or data corruption. Data field: [31:0] - error status from VM_FindShortestRoute [39:32] - Destin…
1.3.6.1.4.1.11.2.23.35.10570NodehpevtErrWrtRemtXbcRoutRegerror writing the remote XBC routing register. Data field: [31:0] - error status from WriteRouteReg [39:32] - XBC ID [51:44] - XBC port number [59:52] - Destin…
1.3.6.1.4.1.11.2.23.35.10571NodehpevtErrEnblRoutRemtXbcerror enabling the routes on the remote XBC. Data field: [31:0] - error status from WriteRouteEnable [39:32] - XBC ID [51:44] - XBC port number [59:52] - Desti…
1.3.6.1.4.1.11.2.23.35.10572NodehpevtErrWrtRoutRegLocXbcError writing the routing register on the local XBC. Data field: [31:0] - error status from WriteRouteReg [39:32] - XBC ID [51:44] - XBC port number
1.3.6.1.4.1.11.2.23.35.10573NodehpevtErrWrtLocXbcRoutRegRchRemtCelError writing the local XBC routing registers to reach a remote cell. Data field: [31:0] - error status from WriteRouteReg [39:32] - XBC ID [51:44] - XBC port …
1.3.6.1.4.1.11.2.23.35.10574NodehpevtErrEnblLocXbcRoutError enabling the local XBC routes. Data field: [31:0] - error status from WriteRouteEnable [39:32] - XBC ID [51:44] - XBC port number
1.3.6.1.4.1.11.2.23.35.10617NodehpevtSynGrphFailPhs4SynchGraphs() failed during Arches Fabric Phase 4. Data field: return value from SynchGraphs()
1.3.6.1.4.1.11.2.23.35.10619NodehpevtVmVertxFailSyncGrphVM_DeleteVertex() failed in SynchGraphs(). Data field: (vertex id << 32) | (vertex type << 56) | (return value from VM_DeleteVertex())
1.3.6.1.4.1.11.2.23.35.10620NodehpevtVmEdgFailFncSyncGrphVM_DeleteEdge() failed in the Arches Fabric function SynchGraphs(). Data field:(vertex id1 << 32) | (vertex port1 << 48) | (vertex type1 << 56) | (vertex id2 <…
1.3.6.1.4.1.11.2.23.35.10621NodehpevtUnexpctErrCalVertxModUnexpected error when calling an Arches Fabric vertex module function. Data field: return value from vertex module function
1.3.6.1.4.1.11.2.23.35.10622NodehpevtUnexpctRetVertxModCopCelGrphUnexpected return from an Arches Fabric vertex module function while copying a cell's graph. Data field: return value from vertex module function
1.3.6.1.4.1.11.2.23.35.10623NodehpevtChecksumPdtFailedThe checksum update for the PDT has failed.
1.3.6.1.4.1.11.2.23.35.10625NodehpevtChecksumNvmBadThe checksum in the memory area of NVM is bad. Memory NVM will be cleared.
1.3.6.1.4.1.11.2.23.35.10626NodehpevtChecksumCalcFailedChecksum calculation failed.
1.3.6.1.4.1.11.2.23.35.10628NodehpevtSalandBmcTokenBadThe BMC copy and SAL copy of the token specified in the data field has been initialized from the default value for the token due to an IPMI error and SAL NVM e…
1.3.6.1.4.1.11.2.23.35.10629NodehpevtBkPlaneCableDetected incompatibility between the cell board and the I/O backplane and/or I/O backplane cables.
1.3.6.1.4.1.11.2.23.35.10698NodehpevtFparUnusableThe fPar identified by the event detail will be unusable. Other events may preceded this event which will help to diagnose the failure. A possible cause is tha…
1.3.6.1.4.1.11.2.23.35.10702NodehpevtFWoutOfNvramFirmware is out of NVRAM and cannot built the ILM memory slice device map
1.3.6.1.4.1.11.2.23.35.10703NodehpevtNvramCPUCorruptThe NVRAM for the CPU map is corrupt and cannot be trusted. It appears that there are more CPUs in the map than the size of the map can hold.
1.3.6.1.4.1.11.2.23.35.10704NodehpevtNvramIOCorruptThe NVRAM for the IO device ownership map is corrupt and cannot be trusted. It appears that there are more IO devices in the map than the size of the map can h…
1.3.6.1.4.1.11.2.23.35.10705NodehpevtNvramLocMemCorruptThe NVRAM for the cell local memory map is corrupt and cannot be trusted. It appears that there are more memory slices in the map than the size of the map can …
1.3.6.1.4.1.11.2.23.35.10706NodehpevtFWInconsistExistAn internal firmware inconsistency exists or the server exhausted its internal resources and is unable to create an fPars EFI ownership variable for a CPU devi…
1.3.6.1.4.1.11.2.23.35.10707NodehpevtFWUnableCreatefParsIOAn internal firmware inconsistency exists or the server exhausted its internal resources and is unable to create an fPars EFI ownership variable for an IO devi…
1.3.6.1.4.1.11.2.23.35.10708NodehpevtFWUnableCreatefParsCLMAn internal firmware inconsistency exists or the server exhausted its internal resources and is unable to create an fPars EFI ownership variable for a CLM devi…
1.3.6.1.4.1.11.2.23.35.10771NodehpevtFWOutOfNvramFirmware has run out of NVRAM and cannot create the needed variable(s)
1.3.6.1.4.1.11.2.23.35.10772NodehpevtFWLbaReconfigFailThe call to the IOC firmware component method 'LbaReconfig' failed, probably a low-level hardware error. The fPar BSP is identified in bits 63..32 of the event…
1.3.6.1.4.1.11.2.23.35.10779NodehpevtCpuModuleBadConfigThe CPU modules have been installed in an illegal configuration on the cell board.
1.3.6.1.4.1.11.2.23.35.10780NodehpevtCpuInvalidTerminatorAn invalid CPU terminator card is installed on the cell board. The data field indicates the physical location of the offending socket.
1.3.6.1.4.1.11.2.23.35.10793NodehpevtInvocationSoftResetCodeInvocation of the soft reset code from an interrupt or similar vector, or improper locking/releasing of semaphores.
1.3.6.1.4.1.11.2.23.35.10794NodehpevtDataSm4SelfResetData field is count of cpus held by the sm4 which issues the event (and is trying to reset itself). Indicates invocation of the SoftResetCpu code from an inter…
1.3.6.1.4.1.11.2.23.35.10795NodehpevtfParsfailRelseResrceA reset of an fPar discovered that an fPar failed to release critical resources within a reasonable time.
1.3.6.1.4.1.11.2.23.35.10814NodehpevtPFMManyErrorsSignificant numbers of corrected memory errors have been detected on the memory subsystem
1.3.6.1.4.1.11.2.23.35.10822NodehpevtPFMOverTempProcOver-temperature condition detected on a processor
1.3.6.1.4.1.11.2.23.35.10823NodehpevtPFMCacheErrorProcCache errors detected on a processor
1.3.6.1.4.1.11.2.23.35.10824NodehpevtPFMCorrecErrorCacheCorrected errors detected in the cache portion of the memory for a processor module
1.3.6.1.4.1.11.2.23.35.10825NodehpevtPFMCorrErrSysBusCorrected errors detected on the system bus for a processor module
1.3.6.1.4.1.11.2.23.35.10826NodehpevtPFMCorrErrProcBusCorrected errors detected on the processor bus for a processor module
1.3.6.1.4.1.11.2.23.35.10827NodehpevtPFMErrTagMemProcCorrected errors detected in the tag portion of the memory for a processor module
1.3.6.1.4.1.11.2.23.35.10830NodehpevtfParsNotEnableBootfPars-mode EFI variable is set to enable fPars operation but no fPars are actually enabled to boot. So the server boots in hard partition mode.
1.3.6.1.4.1.11.2.23.35.10832NodehpevtfParsNotRecveOwnShipAn fPar was directed to reset using the ESIT DirectedfParResetAndMigrate() service but the target (recipient) fPar of the resources is in a state that cannot r…
1.3.6.1.4.1.11.2.23.35.10833NodehpevtFWErrSetNvramValFirmware error setting the NVRAM value of preferred-bsp for the vPars monitor. The partition will boot using the PD monarch, but the value of preferred-bsp may…
1.3.6.1.4.1.11.2.23.35.10842NodehpevtUnablWrtXbcPrtRoutTblEnblMskUnable to write to an XBC port ROUTE_TABLE_ENABLE_MASK CSR in Arches Fabric Phase3. Data field: (XBC port << 48) | (XBC ID < 32) | (route)
1.3.6.1.4.1.11.2.23.35.10853NodehpevtProcessIntrptUnRecoverbleAn unrecoverable processor interrupt occurred. IPF firmware owned the processor interrupt vector table (IVT) at the time of the interrupt.
1.3.6.1.4.1.11.2.23.35.10871NodehpevtSBASetDevMaskFailSBA call to LBA SetDeviceMask method fails.
1.3.6.1.4.1.11.2.23.35.10927NodehpevtLBASlotDevScanErrLBA slot device scan error
1.3.6.1.4.1.11.2.23.35.10936NodehpevtInadequateMemTofParThere is none (or inadequate) memory slice resource assigned to the fPar so it cannot boot its instance. The fPar will be disabled (enter a spinloop) because i…
1.3.6.1.4.1.11.2.23.35.10937NodehpevtFailCollVertxInfoCouldn't collect vertex information during Fabric Info call. Data Field: return status
1.3.6.1.4.1.11.2.23.35.10938NodehpevtFailCollVertxFabInfoCallCouldn't collect the vertices during the Fabric Info call. Data Field: number of vertices returned
1.3.6.1.4.1.11.2.23.35.10939NodehpevtFailFndEdgeProcCallCouldn't find all the edges during a procedure call. Data Field: return status
1.3.6.1.4.1.11.2.23.35.10940NodehpevtFailFndEdgProcCallCouldn't find an appropriate number of edges during a procedure call. Data Field: the number of edges found
1.3.6.1.4.1.11.2.23.35.10941NodehpevtManyEdgEncntProcCallToo many edges were encountered during a procedure call. Data Field: link count
1.3.6.1.4.1.11.2.23.35.10943NodehpevtFailGetAddrProcCallFailed to get an address during a procedure call. Data Field: return status
1.3.6.1.4.1.11.2.23.35.10944NodehpevtUnexpctStatEncntProcCallAn unexpected state was encountered during a procedure call. Data Field: state returned
1.3.6.1.4.1.11.2.23.35.10945NodehpevtUnablGetLnkHlthStatProcCallUnable to get the link health state during a procedure call. Data Field: (cell num << 56) | (port << 44) | (xbc << 32)
1.3.6.1.4.1.11.2.23.35.10946NodehpevtFabDatFailCrcChkThe fabric data failed a CRC check. Data Field: (xbc port << 44 ) | (xbc << 32) | return status)
1.3.6.1.4.1.11.2.23.35.11032NodehpevtVmCollVertcFailUnexpctVM_CollectVertices failed unexpectedly. Could possibly be a data corruption problem. Data field: (cell number << 56) | (return value from VM_CollectVertices)
1.3.6.1.4.1.11.2.23.35.11033NodehpevtUnablGenAlbArfSetCsrUnable to generate an ALB address in Arches Fabric ArfSetDefaultCSRs() function. Data field:(cell number << 56) | (port number << 48) | (xbc ID < 32) | (return…
1.3.6.1.4.1.11.2.23.35.11034NodehpevtSetDefCsrFailUnexpctSetDefaultCSRs function failed unexpectedly. Arches Fabric was unable to set XBC CSRs to default values. Data field: return value from SetDefaultCSRs
1.3.6.1.4.1.11.2.23.35.11038NodehpevtEncntErrRoutA problem was encountered while routing which prevented an appropriate route from being chosen. Data Field: Destination Cell << 56 | XBC Port << 44 | XBC # << …
1.3.6.1.4.1.11.2.23.35.11039NodehpevtEncntErrRoutFabAn error was encountered while routing the fabric. This error prevents an appropriate route from being selected. Data Field: Destination Cell << 56 | XBC Port …
1.3.6.1.4.1.11.2.23.35.11040NodehpevtErrEncntRoutFabPrvntRoutSelAn error was encountered while routing the fabric. This error prevents an appropriate route from being selected. Data Field: Destination Cell << 56 | XBC Port …
1.3.6.1.4.1.11.2.23.35.11041NodehpevtInvlPrtRetRoutXbcCcLnkAn invalid port number was returned when selecting a route for the XBC-CC link. Data Field: (destination cell 56) | (xbc port 44) | (xbc # 32) | port selected
1.3.6.1.4.1.11.2.23.35.11042NodehpevtErrEncntRoutFabPrvntRoutSelSwAn error was encountered while routing the fabric. This error prevents an appropriate route from being selected. Data Field: Destination Cell << 56 | XBC Port …
1.3.6.1.4.1.11.2.23.35.11052NodehpevtSecndFlshNotProgrmValidImgThe second flash part is not programmed with a valid image
1.3.6.1.4.1.11.2.23.35.11452NodehpevtSysBckPlnPwr1p2LDOFaultSystem backplane power has reported a 1.2v LDO fault. The data field contains the physical location of the fault.
1.3.6.1.4.1.11.2.23.35.11454NodehpevtSysBckPlnPwr2p5LDOFaultSystem backplane power has reported a 2.5v LDO fault. The data field contains the physical location of the fault.
1.3.6.1.4.1.11.2.23.35.11456NodehpevtSysBckPlnPwr3p3HseFaultSystem backplane power has reported a 3.3v house keeping power fault. The data field contains the physical location of the fault.
1.3.6.1.4.1.11.2.23.35.11459NodehpevtSysBckPlnPwr12FaultSystem backplane power has reported a 12v power fault. The data field contains the physical location of the fault.
1.3.6.1.4.1.11.2.23.35.11461NodehpevtSysBckPlnPwr3p3FaultSystem backplane power has reported a 3.3v power fault. The data field contains the physical location of the fault.
1.3.6.1.4.1.11.2.23.35.11463NodehpevtSysBckPlnPwr1p5FaultSystem backplane power has reported a 1.5v power fault. The data field contains the physical location of the fault.
1.3.6.1.4.1.11.2.23.35.11465NodehpevtSysBckPlnPwr2p5FaultSystem backplane power has reported a 2.5v power fault. The data field contains the physical location of the fault.
1.3.6.1.4.1.11.2.23.35.11467NodehpevtPwrRailPrvInsuffPwrToBckPlnOne or more power rails is providing insufficient power to the backplane.
1.3.6.1.4.1.11.2.23.35.11468NodehpevtRcsNoProvClkBckPlnClock fault for clocks supplied from the Redundant Clock Source (RCS) board to the system backplane. RCS board is no longer providing clocks to the backplane. …
1.3.6.1.4.1.11.2.23.35.11471NodehpevtHsoFaultOrRemvClock fault for clocks supplied from the Hot Swap Oscillator (HSO) board to the system backplane. HSO has reported a fault or has been removed. The data field …
1.3.6.1.4.1.11.2.23.35.11478NodehpevtOpClkNoMtchRcsHsoThe operational clock frequencies do not match between the Redundant Clock Source (RCS) and the Hot Swap Oscillator (HSO). The data field contains the physical…
1.3.6.1.4.1.11.2.23.35.11479NodehpevtClkMrgnBckPlnFailThe clock margin of the system backplane failed.
1.3.6.1.4.1.11.2.23.35.11481NodehpevtHsoNoRedundSystem backplane Hot Swap Oscillator (HSO) boards are NOT redundant.
1.3.6.1.4.1.11.2.23.35.11482NodehpevtHsoInsuffSystem backplane Hot Swap Oscillator (HSO) boards are insufficient.
1.3.6.1.4.1.11.2.23.35.11483NodehpevtFailRdRcsHsoFailure reading Redundant Clock Source (RCS) or Hot Swap Oscillator HSO boards EEPROM. Data field contains the physical location of the device.
1.3.6.1.4.1.11.2.23.35.11484NodehpevtFailWrtRcsHsoFailure writing Redundant Clock Source (RCS) or Hot Swap Oscillator HSO boards EEPROM. Data field contains the physical location of the device
1.3.6.1.4.1.11.2.23.35.11485NodehpevtFailRdRpmFailure reading the Reset and Power Monitors (RPM) EEPROM. Data field contains the physical location of the device.
1.3.6.1.4.1.11.2.23.35.11486NodehpevtFailWrtRpmFailure writing the Reset and Power Monitors (RPM) EEPROM. Datafield contains the physical location of the device
1.3.6.1.4.1.11.2.23.35.11487NodehpevtFailRdOspFailure reading the Onboard System Programmers (OSP) EEPROM. Datafield contains the physical location of the device
1.3.6.1.4.1.11.2.23.35.11488NodehpevtFailWrtOspFailure writing the Onboard System Programmers (OSP) EEPROM. Datafield contains physical location of the device
1.3.6.1.4.1.11.2.23.35.11489NodehpevtSbsFaultStrtSerial Bit Stream (SBS) fault on startup. An SBS fault results in the MOAB's not being configured correctly.
1.3.6.1.4.1.11.2.23.35.11495NodehpevtFailRdIObckPlnLpmFailure reading IO backplane LPM. Datafield contains the physical location of the device.
1.3.6.1.4.1.11.2.23.35.11496NodehpevtFailWrtIOBckPlnLpmFailure writing IO backplane LPM. Datafield contains physical location of device.
1.3.6.1.4.1.11.2.23.35.11515NodehpevtSysSoftViolateWellBhaveRuleThe system software violated one of the 'well-behavedness' rules of soft partitions and tried to call a firmware procedure within the firmware instance of a si…
1.3.6.1.4.1.11.2.23.35.11521NodehpevtAlbInitPrepUnablRdAlrecConfigAlbInitPrep was unable to read the ALREC_CONFIG CSR to determine whether the link is up or not. Data field: unused
1.3.6.1.4.1.11.2.23.35.11529NodehpevtfParIsDisbleFrmBootThe fPar whose ID is identified in the event detail is disabled from booting because it has no bootable, healthy CPU. It may not own any CPU or the CPUs it own…
1.3.6.1.4.1.11.2.23.35.11530NodehpevtfParNotInstantiateFWNon-critical event announces that an fPar is enabled to boot but has inadequate memory resources to instantiate the firmware for the fPar. The configuration is…
1.3.6.1.4.1.11.2.23.35.11531NodehpevtfParNotHaveIOResrcThe fPar has been enabled to boot, and contains at least one CPU and adequate memory but has not been given any IO resources. The soft partition (fPar) may the…
1.3.6.1.4.1.11.2.23.35.11537NodehpevtCPUsDeconfigAll CPUs were scheduled to be deconfigured
1.3.6.1.4.1.11.2.23.35.11538NodehpevtCPUsReconfigAll CPUs have been auto reconfigured
1.3.6.1.4.1.11.2.23.35.11566NodehpevtIOBckPln33VFailIO Backplane 3.3V power fault
1.3.6.1.4.1.11.2.23.35.11567NodehpevtBckPln5VFailIO Backplane 5.0V power fault
1.3.6.1.4.1.11.2.23.35.11568NodehpevtIOBckPlnNeg12VFailIO Backplane -12V power fault
1.3.6.1.4.1.11.2.23.35.11569NodehpevtIOBckPln12VFailIO Backplane +12V power fault
1.3.6.1.4.1.11.2.23.35.11575NodehpevtIOBckPln15VTempFailIO Backplane 1.5V temperature fault
1.3.6.1.4.1.11.2.23.35.11576NodehpevtIOBckPln33VTempFailIO Backplane 3.3V temperature fault
1.3.6.1.4.1.11.2.23.35.11578NodehpevtIOBckPlnNeg12VTempFailIO Backplane -12.0V temperature fault
1.3.6.1.4.1.11.2.23.35.11579NodehpevtIOBckPln12VTempFailIO Backplane +12.0V temperature fault
1.3.6.1.4.1.11.2.23.35.11580NodehpevtLocCelUnablClrLnkOffBitThe local cell was unable to clear the link_off bit on at least one CC-CC link. Data field: return value of Phase3BackToBackPrep()
1.3.6.1.4.1.11.2.23.35.11581NodehpevtArfOlaPreRendezUnablRchCelArfOLAPreRendez() was unable to reach the added cell. Data field: bitmap of unreachable cells
1.3.6.1.4.1.11.2.23.35.11582NodehpevtUnexpctErrSetNctTblAn unexpected error occurred in SetupNCTable(). Data field: return value from SetupNCTable()
1.3.6.1.4.1.11.2.23.35.11583NodehpevtPhs4UnexpctFailPhase4BackToBackPrep() unexpectedly failed. Data field: return value of Phase4BackToBackPrep()
1.3.6.1.4.1.11.2.23.35.11584NodehpevtUnablSyncGrphCellData field: (master cell number << 56) | (bitmap of cells to synch)
1.3.6.1.4.1.11.2.23.35.11585NodehpevtBitMapUnrchCelData field: bitmap of unreachable cells.
1.3.6.1.4.1.11.2.23.35.11586NodehpevtRetValNctCohTblData field: return value from SetupNCTable() or SetupCohTable()
1.3.6.1.4.1.11.2.23.35.11597NodehpevtArfRoutEnblRetErrLocCelData field: (local cell number << 56) | (bitmap of routes to enable)
1.3.6.1.4.1.11.2.23.35.11598NodehpevtArfRoutDisRetErrOlaData field: (bitmap of cells << 32) | (bitmap of routes to disable)
1.3.6.1.4.1.11.2.23.35.11599NodehpevtArfRoutDisRetErrArfPhs4Data field: (bitmap of source cells << 32) | (bitmap of routes to disable)
1.3.6.1.4.1.11.2.23.35.11603NodehpevtMemAlloctFailMemory allocation failed. The data is the size of the memory block which could not be allocated.
1.3.6.1.4.1.11.2.23.35.11604NodehpevtMemLockFailMemory locking failed. The data is the size of the memory block which could not be locked.
1.3.6.1.4.1.11.2.23.35.11605NodehpevtMinProcReqMoreThanAvailThe minimum number of processors required is more than the number available. The data is the number of available processors.
1.3.6.1.4.1.11.2.23.35.11607NodehpevtVMNotHandlGuestOSPerfThe guest operating system performed an operation which could not be handled by the virtual machine. The virtual machine could not continue running the guest s…
1.3.6.1.4.1.11.2.23.35.11696NodehpevtKernlDrvFailLckMemKernel driver failed to lock memory
1.3.6.1.4.1.11.2.23.35.11700NodehpevtMMIOmapFndInfoInTbleThe code which initializes the MMIO/IOP map found that the table already contained information.
1.3.6.1.4.1.11.2.23.35.11702NodehpevtAttmptAddPCImoreThanAllowAn attempt was made to add a PCI bus with a number greater than the maximum allowed.
1.3.6.1.4.1.11.2.23.35.11703NodehpevtCPUConfigNotSupprtThe configured CPU generation is not supported
1.3.6.1.4.1.11.2.23.35.11705NodehpevtISAUARTcreatWithoutDatStrctAn ISA UART was created without a data structure. A PCI UART structure exists
1.3.6.1.4.1.11.2.23.35.11706NodehpevtTCGETorIOCTLFailA TCGETS or TCSETS IOCTL failed. The errno status will be in a subsequent event.
1.3.6.1.4.1.11.2.23.35.11707NodehpevtStatCallPMANFailA stat call on the PMAN failed. The next event contains the failure errno.
1.3.6.1.4.1.11.2.23.35.11708NodehpevtVMDrvNotOpenThe virtual machine driver could not be opened
1.3.6.1.4.1.11.2.23.35.11709NodehpevtVMDrvNotCreatVMThe virtual machine driver could not create a virtual machine
1.3.6.1.4.1.11.2.23.35.11710NodehpevtNotAbleCreatNodeForCommCould not create a file system node for communication between the vmm driver and the virtual machine. The next event contains the error from the Unix system ca…
1.3.6.1.4.1.11.2.23.35.11711NodehpevtVMNotOpenThe vm device was created but cannot be opened
1.3.6.1.4.1.11.2.23.35.11712NodehpevtVMDrvNotLoadThe virtual machine driver has not been loaded
1.3.6.1.4.1.11.2.23.35.11718NodehpevtCreatThreadPMANFailAn attempt to create a thread on the PMAN has failed. The next event contains the Unix error number.
1.3.6.1.4.1.11.2.23.35.11719NodehpevtVMDrvUnableCommVMVM Driver was unable to communicate with virtual machine
1.3.6.1.4.1.11.2.23.35.11720NodehpevtConfigUnableToRdThe configuration file could not be read
1.3.6.1.4.1.11.2.23.35.11721NodehpevtMemAllocFWTblFailMemory allocation for a firmware table has failed. The data contains the name of the firmware table.
1.3.6.1.4.1.11.2.23.35.11723NodehpevtDrvUnableBldMapTblDriver was unable to build map tables
1.3.6.1.4.1.11.2.23.35.11724NodehpevtVMRebootFailReboot failed. The virtual machine will exit.
1.3.6.1.4.1.11.2.23.35.11775NodehpevtSetIntlCohTblRetErrData field: (cell set << 32) | (return value from SetupInitialCohTables())
1.3.6.1.4.1.11.2.23.35.11780NodehpBootStblStoreFlashErrStable store read or write to flash failed.
1.3.6.1.4.1.11.2.23.35.11783NodehpBootStblStoreNvMErrError reading or writing the stable store NVM area
1.3.6.1.4.1.11.2.23.35.11784NodehpevtFWDetectilleglMemConfigSFW has detected an illegal memory config using 4GB DIMMs. The system will be halted
1.3.6.1.4.1.11.2.23.35.11788NodehpevtSFWFailAllotNVMSFW component NVM space is not big enough to store all it data. Check the ASCII data field to determine which component caused the error.
1.3.6.1.4.1.11.2.23.35.11789NodehpevtSFWFailAllotSCRRAMSFW component does not allocate enough SCR ram space to store it data.
1.3.6.1.4.1.11.2.23.35.11797NodehpevtSetIntlCohRetErrArfPhs3Data field: cell set [63:32], return value [31:0]
1.3.6.1.4.1.11.2.23.35.11807NodehpevtErrWrtErrMskAlrecAlTranData field: cell ID [63:56], port num [55:44], XBC ID [43:32]
1.3.6.1.4.1.11.2.23.35.11840NodehpevtFwUnexpctIntrnlErrVertxData field: vType1 [63:56] | vPort1 [55:48] | vId1 [47:32] | vType2 [31:24] | vPort2 [23:16] | vId2 [15:0]
1.3.6.1.4.1.11.2.23.35.11850NodehpOsUnsupportedWmixedCpuRevsThe OS being booted is not supported in a partition containing a mix of processor stepping revisions.
1.3.6.1.4.1.11.2.23.35.11851NodehpevtFwUnexpctErrSetLnkData field: vType1 [63:56] | vPort1 [55:48] | vId1 [47:32] | vType2 [31:24] | vPort2 [23:16] | vId2 [15:0]
1.3.6.1.4.1.11.2.23.35.11863NodehpevtFwUnbleWrtSkyGlobLnkSelCohData field: cell num [63:56] | link sel coh CSR (0 or 1) [0:0]
1.3.6.1.4.1.11.2.23.35.11870NodehpOsBootDisabledWmixedCpuKeysThe OS suitable for booting in this mode does not support booting in the current configuration due to the existence of cpus of differing revisions.
1.3.6.1.4.1.11.2.23.35.11885NodehpevtSysFwErrUpdtLnkSystem firmware experienced an error while updating the link sel value. Data field indicates return status
1.3.6.1.4.1.11.2.23.35.11904NodehpevtFabUnablGenSkyCsrAddrFabric was unable to generate a Skyline CSR address Data field: cell number [63:56] and return value from address function [31:0]
1.3.6.1.4.1.11.2.23.35.11905NodehpevtFwUnablGenSkyCsrAdrrFirmware was unable to generate a Skyline CSR address. Data field: cell number [63:56] | return value [31:0]
1.3.6.1.4.1.11.2.23.35.11932NodehpevtNoOSBootRendezTarget CPU receives wakeup interrupt to join the OS but the OS_BOOT_RENDEZ entry point is invalid or none-existent
1.3.6.1.4.1.11.2.23.35.11933NodehpevtChksmFailOSBootRendezThe entry point for OS_BOOT_RENDEZ exists, but fails the checksum test performed by firmware
1.3.6.1.4.1.11.2.23.35.11960NodehpevtSysFWCallPalCopyInfoFailThe System Firmware call to PAL_COPY_INFO failed.
1.3.6.1.4.1.11.2.23.35.11961NodehpevtSysFWCallPalCopyPalFailThe System Firmware call to PAL_COPY_PAL failed.
1.3.6.1.4.1.11.2.23.35.11962NodehpevtSysFWCallPalCacFlusFailThe System Firmware call to PAL_CACHE_FLUSH failed.
1.3.6.1.4.1.11.2.23.35.11964NodehpevtCellNotInitCell on line add/delete is not initialized and cannot be used.
1.3.6.1.4.1.11.2.23.35.11966NodehpevtFPARsCompBrokeIn FPARs mode, cell on line add/delete depends on functionality in the FPARs component. This is either broken or missing.
1.3.6.1.4.1.11.2.23.35.11967NodehpevtFailGetFPARsSemphrCell on line add/delete in FPARs mode failed to get the FPARs semaphore.
1.3.6.1.4.1.11.2.23.35.11968NodehpevtMorThnOneProcCallCellMore than one processor from an FPAR called into cell on line add/delete
1.3.6.1.4.1.11.2.23.35.11969NodehpevtFPARsProcFailRendezAll FPARs processors failed to rendezvous during a cell on line add/delete op
1.3.6.1.4.1.11.2.23.35.11970NodehpevtEncntUnexptErrOLAUnable to setup Skyline LINK_SEL_COHx CSRs on the running partition to the newly added cell. Data field: cell set [63:32] | return val [31:0]
1.3.6.1.4.1.11.2.23.35.11971NodehpevtMCAOccPriorPreMCAThis indicates an MCA happening before a previous MCA was not completely handled.
1.3.6.1.4.1.11.2.23.35.11972NodehpevtMCAInitEvtProcThis indicates an MCA event happening before a previous INIT event was not completely processed.
1.3.6.1.4.1.11.2.23.35.11974NodehpevtUnablFndBadEdgFirmware was unable to find a bad edge in an untraversable route. Data Field: (destCell << 56 | port num < 44 | xbc num << 32 | return status)
1.3.6.1.4.1.11.2.23.35.11989NodehpevtUnknEntityDrwPwrBusSome entity that is not known to the firmware, is drawing power from the bus bars.
1.3.6.1.4.1.11.2.23.35.12001NodehpevtSoftPartNotBootRebooting the partition to nPars because a soft partition could not be booted.
1.3.6.1.4.1.11.2.23.35.12008NodehpevtUnablRotArndBrkLnkFirmware was unable to find a replacement route for the broken link. Data field contains: port << 44, chip id << 32, and number of attempts to find an alternat…
1.3.6.1.4.1.11.2.23.35.12013NodehpevtUnablSetAPERLockData field details the cell that failed to set its bit
1.3.6.1.4.1.11.2.23.35.12017NodehpevtUncorrtMemEccErrOccrIndicates that an uncorrectable ECC error has been encountered, and gives the physical location of the DIMM that had the error.
1.3.6.1.4.1.11.2.23.35.12025NodehpevtErrRetrvCrssbarLnkSystem firmware experienced an error while retrieving the expected neighbor fabric chip for distributing traffic over crossbarl inks. Data Field: (xbc port # <…
1.3.6.1.4.1.11.2.23.35.12028NodehpevtUnablRdCrssbarCould not read crossbar neighbor information during routing. Data Field: (xbc port << 44) | (xbc << 32) | error status
1.3.6.1.4.1.11.2.23.35.12029NodehpevtUnablEstbshCrssbarCould not establish route for local crossbar during route around routing. Data Field: (xbc port << 44) | (xbc << 32) | error status
1.3.6.1.4.1.11.2.23.35.12047NodehpevtNoRoutLocCrssBarAn invalid TPM has been detected in the system and is being use. Security might be compromised. Data field unused.
1.3.6.1.4.1.11.2.23.35.12048NodehpevtInvalidTPMInvalid or unsupported TPM detected in the system. TPM is disabled. Data filed unused
1.3.6.1.4.1.11.2.23.35.12049NodehpevtTPMFailInitFirmware cannot initialize the TPM. TPM related security feature are disabled Data field unused
1.3.6.1.4.1.11.2.23.35.12050NodehpevtCpuTempExceedHiThresA CPU module's temperature has exceed the high temperature threshold or a CPU power module fault has occurred. As a result of this event, the CPU has been inhi…
1.3.6.1.4.1.11.2.23.35.12069NodehpevtSFWDetErrStablStorFlshAn error occurred while writing to stable store flash. Data field is unused.
1.3.6.1.4.1.11.2.23.35.12091NodehpevtInlckOpenPCIPwrPCI interlock has been opened with PCI slot power on. The datafield can be decoded as follows (where byte 0 is the rightmost byte): byte offset 2:PCI slot numb…
1.3.6.1.4.1.11.2.23.35.12101NodehpevtFaltDetDropRegIOThe specified low dropout regulator on the IO backplane is reporting a fault. The specified power rail is reporting a fault. The number in the slot field of th…
1.3.6.1.4.1.11.2.23.35.12102NodehpevtFaltDetDropRegManBckPlneThe specified low dropout regulator on the main backplane is reporting a fault. The number in the slot field of the physical location is the rail number that c…
1.3.6.1.4.1.11.2.23.35.12103NodehpevtFaltDetHotswpCoreIOThe hot swap controller for the specified core IO is reporting fault.
1.3.6.1.4.1.11.2.23.35.12109NodehpevtErrRetrvCrssbarChipNmbrAn error occurred while retrieving the crossbar chip number. Data Field: cell number << 56 | port number << 44 | return status
1.3.6.1.4.1.11.2.23.35.12119NodehpevtCellNotCfgCLMModeFor most workloads, the system performance may be degraded if CLM mode is not enabled for all of the cells in a partition. Windows Server 2003 contains additio…
1.3.6.1.4.1.11.2.23.35.12120NodehpevttDoblDramInvokeCorrected memory errors have been detected. Double DRAM chip sparing events have been invoked.
1.3.6.1.4.1.11.2.23.35.12121NodehpevtErrCrssbarCrctByHWA error occurred in the crossbar controller and was corrected by the hardware.
1.3.6.1.4.1.11.2.23.35.12127NodehpevtErrCrssChipBckPlnA platform error was detected by the firmware/hardware, and corrected by using a spare channel. The error occurred between the crossbar chips on the backplane(…
1.3.6.1.4.1.11.2.23.35.12128NodehpevtErrCeLLIOA platform error was detected by the firmware/hardware, and corrected by using a spare channel. The error occurred between the cell controller and the IO contr…
1.3.6.1.4.1.11.2.23.35.12129NodehpevtMltPltFrmErrCellBckPlnMultiple platform errors were detected and corrected by the firmware/hardware. The errors occurred between the cell controller and the backplane.
1.3.6.1.4.1.11.2.23.35.12130NodehpevtMultPltFrmErrCrssChpBckPlnMultiple platform errors were detected and corrected by the firmware/hardware. The errors occurred between the crossbar chips on the backplane(s).
1.3.6.1.4.1.11.2.23.35.12131NodehpevtMultPltFrmErrCeLLIOMultiple platform errors were detected and corrected by the firmware/hardware. The errors occurred between the cell controller and the IO controller.
1.3.6.1.4.1.11.2.23.35.12132NodehpevtServIDNotMatchCabThe server identification information does not match the cabinet type. The server will not power on until this condition is resolved.
1.3.6.1.4.1.11.2.23.35.12135NodehpevtDupDimNumDetectDuplicate DIMM serial numbers have been detected. Data field gives physical location of DIMM. Check for other events specifying other DIMMs with same serial nu…
1.3.6.1.4.1.11.2.23.35.12143NodehpevtMPLostUPSThe MP has lost communications with the UPS via SNMP over the LAN
1.3.6.1.4.1.11.2.23.35.12144NodehpevtMPGainLanCommUPSThe MP lan communications with the UPS have been restored.
1.3.6.1.4.1.11.2.23.35.12149NodehpevtUnrecovProcIFAinterptInFWAn unrecoverable processor interrupt occurred while in IPF firmware. The data value is the processor IFA.
1.3.6.1.4.1.11.2.23.35.12150NodehpevtUnrecovProcISRinterptInFWAn unrecoverable processor interrupt occurred while in IPF firmware. The event data is the processor ISR.
1.3.6.1.4.1.11.2.23.35.12153NodehpevtDblChipSpareInvokedSystem firmware has detected and corrected memory errors. Double chip sparing has been invoked to help mitigate this condition.
1.3.6.1.4.1.11.2.23.35.12155NodehpevtExtClkCablRemvFrmCPUCabExternal clock cable has been removed from the CPU cabinet. The data field contains the physical location of the cabinet.
1.3.6.1.4.1.11.2.23.35.12156NodehpevtSysFabEncntLnkErrSystem Fabric encountered a link error after opening up the fabric link
1.3.6.1.4.1.11.2.23.35.12157NodehpevtFatErrOnCelToFabPrt44I32I1Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port << 44) | (crossbar << 32) | 1
1.3.6.1.4.1.11.2.23.35.12159NodehpevtSysFWgetFabProblmSystem firmware encountered fabric problems. Data Field: (crossbar port << 44) | (crossbar << 32)
1.3.6.1.4.1.11.2.23.35.12160NodehpevtFatErrCelLnkToFabPrt44I32Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port << 44) | (crossbar << 32)
1.3.6.1.4.1.11.2.23.35.12161NodehpevtSysOSRecovFrmPCIErrL1A PCI error occurred, but the OS recovered.
1.3.6.1.4.1.11.2.23.35.12162NodehpevtSysOSRecovFrmPCIErrL2A PCI error occurred, but the operating system recovered.
1.3.6.1.4.1.11.2.23.35.12163NodehpevtSysOSRecovFrmPCIErrL5A PCI error occurred, but the operating system recovered
1.3.6.1.4.1.11.2.23.35.12164NodehpevtReqPwrOnDeniedThe request to power on, either via MP user interface, power button, or other, was denied by the Onboard Administrator.
1.3.6.1.4.1.11.2.23.35.12165NodehpevtBladeFrcPWonThe blade has been forced to power-on, either via the MP user interface or the power button. The blade did not negotiate with the Onboard Administrator to insu…
1.3.6.1.4.1.11.2.23.35.12168NodehpevtMPNotRecvRespEnclMangrThe MP has repeatedly tried to communicate with the Onboard Administrator and has not received any response
1.3.6.1.4.1.11.2.23.35.12193NodehpevtIntrnlSwErr7193This is an internal SW error
1.3.6.1.4.1.11.2.23.35.12194NodehpevtIntrnlSwErr7194This is an internal SFW error
1.3.6.1.4.1.11.2.23.35.12195NodehpevtIntrnlSwErr7195This is an internal SFW error
1.3.6.1.4.1.11.2.23.35.12196NodehpevtIntrnlSwErr7196This is an internal SFW error
1.3.6.1.4.1.11.2.23.35.12199NodehpevtComplxProfNoMtchThere are miscompares in the complex profiles between cells in a partition. Data field is unused, earlier events will give more detail.
1.3.6.1.4.1.11.2.23.35.12204NodehpevtIODevMissCoreAn I/O device is missing from the Core I/O. Internal peripherals may be not accessible.
1.3.6.1.4.1.11.2.23.35.12207NodehpevtFparUnablNotiCPUAn fPar's GPE_EN bits are not set up to handle receiving a CPU migrate. This event is emitted 2 times, the Data field is different each time. 1. Data field: Ad…
1.3.6.1.4.1.11.2.23.35.12208NodehpevtFparUnablNotiCpuIOSAPICredirFSHWA was unable to notify the new owner of a CPU migrate. This event is emitted 2 times: 1. Data field: IOSAPIC Address 2. Data field: Virtual IOSAPIC SCI red…
1.3.6.1.4.1.11.2.23.35.12210NodehpevtOSSetWtchDogTimerToTimeOutThe operating system set the watchdog timer to time out if it was not reset within a specified time. It was not reset and has timed out. The management process…
1.3.6.1.4.1.11.2.23.35.12217NodehpevtOSShtDwnDueMCAAn OS is shutting down due to an MCA (Machine Check Abort) or INIT.
1.3.6.1.4.1.11.2.23.35.12218NodehpevtOSShtDwnDuePanicAn OS is shutting down due to a panic.
1.3.6.1.4.1.11.2.23.35.12222NodehpevtCLUFWIncomptblSysTypeFollowing an in-the-box system type upgrade, or after a UGUY board was replaced, the CLU FW may not have been updated to an appropriate revision for the system…
1.3.6.1.4.1.11.2.23.35.12227NodehpevtOnlnIdentHWProbDiagnostics running under the OS have detected a problem with the identified hardware.
1.3.6.1.4.1.11.2.23.35.12228NodehpevtProcOvTempThe processor temperature has exceeded normal limits. HP's Enhanced Thermal Management (ETM) feature has been employed to cool the processor. If the temperatur…
1.3.6.1.4.1.11.2.23.35.12229NodehpevtErrChkFabBootStatAn error occurred while checking the fabricless boot state
1.3.6.1.4.1.11.2.23.35.12230NodehpevtSysFwUnblClrLnkErrMskSystem firmware was unable to clear the link error masks
1.3.6.1.4.1.11.2.23.35.12231NodehpevtSysFwNotDetLnkAdrrSystem firmware could not determine a link's address
1.3.6.1.4.1.11.2.23.35.12232NodehpevtSysFwUnblTurnBadLnkOffSystem firmware was unable to turn a bad link off
1.3.6.1.4.1.11.2.23.35.12244NodehpevtWindWtchDogXpiredThe Wiindows watchdog timer has expired. The nPartition will either be reset or powered off. The data field contains the following information: byte 2 - cell s…
1.3.6.1.4.1.11.2.23.35.12251NodehpevtMPCtrlReprtMPBusCommFailAn MP Bus communications device is reporting a hardware revision that is known to cause MP Bus communications failures. The value in the data field indicates t…
1.3.6.1.4.1.11.2.23.35.12255Nodehpevt12VPCIFailonIOChassMain power at the PCI slot located on the IO Chassis has faulted.
1.3.6.1.4.1.11.2.23.35.12289NodehpevtSFWDetFailOptmzFabA failure was encountered while running the Fabric API to optimize the fabric.
1.3.6.1.4.1.11.2.23.35.12291NodehpevtCritFailCellOnlineA critical failure occurred during a cell online add or delete call.
1.3.6.1.4.1.11.2.23.35.12296NodehpevtCellHasIncomptbleHwFWA cell being added is not compatible with the partition.
1.3.6.1.4.1.11.2.23.35.12297NodehpevtCellFWnotMatchPartFWThe Firmware revision of the cell being added is different from the nPar.
1.3.6.1.4.1.11.2.23.35.12319NodehpevtVMSDetctUnrecvrdEvntThe OpenVMS system has failed and will reboot
1.3.6.1.4.1.11.2.23.35.12324NodehpevtBadCellBrdOrBadProcBrdBad cell board (on cellular system), or bad processor board (on non-cellular system).
1.3.6.1.4.1.11.2.23.35.12343NodehpevtCPUDegradErrThirdCacheCPU performance degraded due to excessive errors in third level cache.
1.3.6.1.4.1.11.2.23.35.12352NodehpevtROMFailAuthentcThe alternate ROM failed to authenticate. The current (primary) ROM will continue to be used
1.3.6.1.4.1.11.2.23.35.12354NodehpevtAltrntROMUnblSwapThe alternate ROM was successfully authenticated but the primary and alternate ROM could not be swapped. The current primary will still be used
1.3.6.1.4.1.11.2.23.35.12358NodehpevtPciSlotErrDetectPCI/PCIX/PCIe card/slot error detected during IO bus scan
1.3.6.1.4.1.11.2.23.35.12394NodehpevtCCLinkDownA CC to CC link failed to train in a 2-cell system. The partition can still boot, but with less redundancy and bandwidth. Data field: Cell number [63:56] Link …
1.3.6.1.4.1.11.2.23.35.12395NodehpevtUnrecovProcIntOccrAn unrecoverable processor interrupt occurred while in IPF firmware. The event data is the processor status register.
1.3.6.1.4.1.11.2.23.35.12399NodehpevtElectrncKeyProblmThe 'e-keying error' only occurs during the power-up if the SVB must be left off due to an electronic keying problem.
1.3.6.1.4.1.11.2.23.35.12400NodehpevtBldeInstImproperLocThe 'location error' only occurs during power-up if the SVB must be left off due to being installed in an improper location in the enclosure (SVBs must be inst…
1.3.6.1.4.1.11.2.23.35.12401NodehpevtbldeInstViolateEnclreThe 'ccoling error' occurs during the power-up if the SVB must be left off due to insufficient cooling; more fans may be needed.
1.3.6.1.4.1.11.2.23.35.12403Nodehpevtsx2000FabRprtUnexpctErrData field: return value from internal firmware function.
1.3.6.1.4.1.11.2.23.35.12408NodehpevtOANotServPwrOnReqstOA is Busy: The Powe-on request cannot be completed.
1.3.6.1.4.1.11.2.23.35.12411NodehpevtIOBckPlnReprtNonRedundncyPCIPwrThe IO backplane in the specified cabinet is reporting a non-redundant PCI power condition.
1.3.6.1.4.1.11.2.23.35.12503NodehpevtUSBStorAttchThis trap is sent when a USB storage device has been attached.
1.3.6.1.4.1.11.2.23.35.12504NodehpevtUSBStorRemovedThis trap is sent when a attached USB storage device is removed.
1.3.6.1.4.1.11.2.23.35.12547NodehpevtMigratSrcNotConntThe migration source could not connect to the target.
1.3.6.1.4.1.11.2.23.35.12548NodehpevtMigratFailA migration has failed.
1.3.6.1.4.1.11.2.23.35.12550NodehpevtMigratNotSuccessA migration was not successful. This contains the migration phase when it was terminated.
1.3.6.1.4.1.11.2.23.35.12551NodehpevtVMNotAlloctMemForIOA virtual machine was not able to obtain memory for an I/O device.
1.3.6.1.4.1.11.2.23.35.12557NodehpevtUnSupprtDimmInPartitionHP PFM service has detected HP unsupported DIMM(s) on this partition.
1.3.6.1.4.1.11.2.23.35.12560NodehpevtRuntimeCritShtDwnOS run-time critical shutdown has occurred.
1.3.6.1.4.1.11.2.23.35.12586NodehpevtPwrExptGreatrPwrBulkThe amount of power expected to be drawn by the currently operating hardware is greater than the rating of the currently operating Bulk Power Supplies (BPS). I…
1.3.6.1.4.1.11.2.23.35.12589NodehpevtBulkPwrReduncLostBulk power supply (BPS) redundancy has been lost on one or more row(s) of power supplies in the complex. The further loss of a single BPS or an AC grid will mo…
1.3.6.1.4.1.11.2.23.35.12591NodehpevtACReduncLostAC redundancy has been lost on one or more row(s) of power supplies in the complex. The further loss of a single Bulk Power Supply (BPS) or the other AC grid w…
1.3.6.1.4.1.11.2.23.35.12593NodehpevtFanCoolNotReduncThe fans that cool a region of the system are not redundant. If an additional fan fails in or is removed from this cooling domain, the partitions on this syste…
1.3.6.1.4.1.11.2.23.35.12595NodehpevtFanInsufficientInCoolDomainAn insufficient number of fans are working in a cooling domain to permit system operation. Running partitions will be shut down immediately to prevent system d…
1.3.6.1.4.1.11.2.23.35.12627NodehpevtOSNotUseAllProcsOperating system is not using all available processors for the current system.
1.3.6.1.4.1.11.2.23.35.12863NodehpevtFMPUnexpctRstHasRcvA Fabric Message Processor (FMP) has unexpectedly reset. The system has recovered from the problem.
1.3.6.1.4.1.11.2.23.45NodehpIpf02Events