MIB Viewer

HPN-ICF-ENTITY-EXT-MIB

131 objects
The private MIB file includes the general extent information of the device.
OIDNameAccessStatusDescription
1.3.6.1.4.1.11.2.14.11.15.2.6IdentityhpnicfEntityExtendThe private MIB file includes the general extent information of the device.
1.3.6.1.4.1.11.2.14.11.15.2.6.1NodehpnicfEntityExtObjects
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1NodehpnicfEntityExtState
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1TablehpnicfEntityExtStateTablenot-accessiblecurrentThis table contains one row per physical entity, There is always at least one row for an 'overall' physical entity. The information in each row may be not incl…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1RowhpnicfEntityExtStateEntrynot-accessiblecurrentThe information about a particular physical entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.1ColumnhpnicfEntityExtPhysicalIndexaccessible-for-notifycurrentThe index of hpnicfEntityExtStateTable. This index is identical to entPhysicalIndex in ENTITY-MIB
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.2ColumnhpnicfEntityExtAdminStatusread-writecurrentThe administrative state for this object.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.3ColumnhpnicfEntityExtOperStatusread-onlycurrentThe operate state for this object.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.4ColumnhpnicfEntityExtStandbyStatusread-onlycurrentThis object is used for monitoring standby status. Not all entities support this object.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.5ColumnhpnicfEntityExtAlarmLightread-onlycurrentThe alarm status for this entity. It does not include the severity of alarms raised on child components. In this condition, there will be a alarm light on the …
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.6ColumnhpnicfEntityExtCpuUsageread-onlycurrentThe CPU usage for this entity. Generally, the overall CPU usage on the entity is calculated, independent of the number of CPUs on the entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.7ColumnhpnicfEntityExtCpuUsageThresholdread-writecurrentThe threshold for the CPU usage. When the CPU usage exceeds the threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.8ColumnhpnicfEntityExtMemUsageread-onlycurrentThe memory usage for the entity. This object indicates what percent of memory are used.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.9ColumnhpnicfEntityExtMemUsageThresholdread-writecurrentThe threshold for the Memory usage, When the memory usage exceeds the threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.10ColumnhpnicfEntityExtMemSizeread-onlycurrentThe size of memory for the entity. If the amount of memory exceeds 4,294,967,295 bytes, the value remains 4,294,967,295 bytes.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.11ColumnhpnicfEntityExtUpTimeread-onlycurrentThe uptime for the entity. The meaning of uptime is when the entity is up, and the value of the object will add 1 seconds while the entity is running.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.12ColumnhpnicfEntityExtTemperatureread-onlycurrentThe temperature for the entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.13ColumnhpnicfEntityExtTemperatureThresholdread-writecurrentThe threshold for the temperature. When the temperature exceeds the threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.14ColumnhpnicfEntityExtVoltageread-onlycurrentThe voltage for the entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.15ColumnhpnicfEntityExtVoltageLowThresholdread-writecurrentThe low-threshold for the voltage. When voltage is lower than low-threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.16ColumnhpnicfEntityExtVoltageHighThresholdread-writecurrentThe high-threshold for the voltage. When voltage greater than high-threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.17ColumnhpnicfEntityExtCriticalTemperatureThresholdread-writecurrentThe threshold for the critical Temperature. When temperature exceeds the critical temperature, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.18ColumnhpnicfEntityExtMacAddressread-onlycurrentMAC Address of the entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.19ColumnhpnicfEntityExtErrorStatusread-onlycurrentIndicate the error state of this entity object. Now it only supports Port, general power supply, RPS power supply and board/Subcard. It may have one of these v…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.20ColumnhpnicfEntityExtCpuMaxUsageread-onlycurrentThe maximal CPU usage for the entity in the period of time.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.21ColumnhpnicfEntityExtLowerTemperatureThresholdread-writecurrentThe threshold for the lower Temperature. When temperature runs under the threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.22ColumnhpnicfEntityExtShutdownTemperatureThresholdread-writecurrentThe threshold for the shutdown Temperature. When temperature exceeds the threshold, a notification will be sent and the entity will be shutdown.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.23ColumnhpnicfEntityExtPhyMemSizeread-onlycurrentThe memory size of entity. This is the physical attribute of entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.24ColumnhpnicfEntityExtPhyCpuFrequencyread-onlycurrentThe CPU frequency of entity. Unit of measure is MHZ.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.25ColumnhpnicfEntityExtFirstUsedDateread-onlycurrentThe first used date of the entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.26ColumnhpnicfEntityExtCpuAvgUsageread-onlycurrentThe average CPU usage for the entity in a period of time.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.27ColumnhpnicfEntityExtMemAvgUsageread-onlycurrentThe average memory usage for the entity in a period of time.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.28ColumnhpnicfEntityExtMemTyperead-onlycurrentThe memory type of entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.29ColumnhpnicfEntityExtCriticalLowerTemperatureThresholdread-writecurrentThe threshold for the critical Temperature. When temperature exceeds the critical lower temperature, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.30ColumnhpnicfEntityExtShutdownLowerTemperatureThresholdread-writecurrentThe threshold for the shutdown Temperature. When temperature exceeds the lower threshold, a notification will be sent and the entity will be shutdown.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.31ColumnhpnicfEntityExtCpuUsageRecoverThresholdread-writecurrentThe recover threshold for the CPU usage. When the CPU usage falls down to the threshold, a notification is sent. The hpnicfEntityExtCpuUsageRecoverThreshold mu…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.32ColumnhpnicfEntityExtMemSizeRevread-onlycurrentSize of memory space for the entity. This node is used to replace hpnicfEntityExtMemSize.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.33ColumnhpnicfEntityExtCpuUsageIn1Minuteread-onlycurrentThe CPU usage in last one minute for this entity. Generally, the overall CPU usage on the entity is calculated, independent of the number of CPUs on the entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.34ColumnhpnicfEntityExtCpuUsageIn5Minutesread-onlycurrentThe CPU usage in last five minutes for this entity. Generally, the overall CPU usage on the entity is calculated, independent of the number of CPUs on the enti…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.2NodehpnicfEntityExtManu
1.3.6.1.4.1.11.2.14.11.15.2.6.1.2.1TablehpnicfEntityExtManuTablenot-accessiblecurrentThe table about device manufacture information.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.2.1.1RowhpnicfEntityExtManuEntrynot-accessiblecurrentThe device manufacture information about a particular physical entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.2.1.1.1ColumnhpnicfEntityExtManuPhysicalIndexaccessible-for-notifycurrentThe index of hpnicfEntityExtManuTable. This index is identical to entPhysicalIndex in ENTITY-MIB.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.2.1.1.2ColumnhpnicfEntityExtManuSerialNumread-onlycurrentManufacture serial number. The manufacture serial number of the entity such as chassis, module, and so on. It is got from the device when manufacturing. For lo…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.2.1.1.3ColumnhpnicfEntityExtManuBuildInforead-onlycurrentDevice version information. The device version information of the entity such as chassis, module, and so on. It consists of software version information and ha…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.2.1.1.4ColumnhpnicfEntityExtManuBOMread-onlycurrentDevice BOM code. The device BOM code of the entity such as chassis, module, and so on. It is the component code of ERP system, which can be disassembled from d…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.2.1.1.5ColumnhpnicfEntityExtMacAddressCountread-onlycurrentMAC address count. The count of MAC addresses of the entity, such as chassis, module, or port, and so on.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.3NodehpnicfEntityExtPower
1.3.6.1.4.1.11.2.14.11.15.2.6.1.3.1TablehpnicfEntityExtPowerTablenot-accessiblecurrentThis table describes the power information of all the physical entity on the device, such as the fans, the subcards, the boards, etc.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.3.1.1RowhpnicfEntityExtPowerEntrynot-accessiblecurrentThe entity power information about a particular physical entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.3.1.1.1ColumnhpnicfEntityExtPowerPhysicalIndexaccessible-for-notifycurrentThe index of hpnicfEntityExtPowerTable. This index is identical to entPhysicalIndex in ENTITY-MIB.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.3.1.1.2ColumnhpnicfEntityExtNominalPowerread-onlycurrentThe nominal power of the entity expressed in milliWatts.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.3.1.1.3ColumnhpnicfEntityExtCurrentPowerread-onlycurrentThe measured usage power of the entity expressed in milliWatts.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.3.1.1.4ColumnhpnicfEntityExtAveragePowerread-writecurrentThe average power consumed by the entity expressed in milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to t…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.3.1.1.5ColumnhpnicfEntityExtPeakPowerread-writecurrentThe peak power consumed by the entity expressed in milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.4NodehpnicfProcessObjects
1.3.6.1.4.1.11.2.14.11.15.2.6.1.4.1TablehpnicfProcessTablenot-accessiblecurrentThe Table describes the information about a particular process, namely a task.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.4.1.1RowhpnicfProcessEntrynot-accessiblecurrentThe information about a particular process, namely a task.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.4.1.1.1ColumnhpnicfProcessIDread-onlycurrentThis object indicates the identifier of process, namely task ID in system.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.4.1.1.2ColumnhpnicfProcessNameread-onlycurrentThis object indicates the process name.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.4.1.1.3ColumnhpnicfProcessUtil5Minread-onlycurrentThis object provides a general idea of how busy a process caused the processor to be over a 5 minute period. The ratio is calculated by the overall CPU usage c…
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5NodehpnicfEntityExtVoltageObjects
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5.1TablehpnicfEntityExtVoltageTablenot-accessiblecurrentThe table describes the voltage information of the voltage sensor entities on the device.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5.1.1RowhpnicfEntityExtVoltageEntrynot-accessiblecurrentThe voltage information of the voltage sensor entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5.1.1.1ColumnhpnicfEntityExtCurrentVoltageread-onlycurrentThe current voltage in millivolts of the voltage sensor entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5.1.1.2ColumnhpnicfEntityExtNominalVoltageread-onlycurrentThe nominal voltage in millivolts of the voltage sensor entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5.1.1.3ColumnhpnicfEntityExtVoltageStateread-onlycurrentThe voltage state of the voltage sensor entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5.1.1.4ColumnhpnicfEntityExtVoltageMajorLowThresholdread-onlycurrentThe low threshold for the voltage sensor entity. When the voltage is lower than the threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5.1.1.5ColumnhpnicfEntityExtVoltageFatalLowThresholdread-onlycurrentThe fatal low voltage threshold for the voltage sensor entity. When the voltage is lower than the threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5.1.1.6ColumnhpnicfEntityExtVoltageMajorHighThresholdread-onlycurrentThe high threshold for the voltage sensor entity. When the voltage is higher than the threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.1.5.1.1.7ColumnhpnicfEntityExtVoltageFatalHighThresholdread-onlycurrentThe fatal high threshold for the voltage sensor entity. When the voltage is higher than the threshold, a notification will be sent.
1.3.6.1.4.1.11.2.14.11.15.2.6.2NodehpnicfEntityExtTraps
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0NodehpnicfEntityExtTrapsPrefix
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.1NotificationhpnicfEntityExtTemperatureThresholdNotificationcurrentThe hpnicfEntityExtTemperatureThresholdNotification indicates the temperature exceeded the threshold. In this condition, user should check the status and the e…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.2NotificationhpnicfEntityExtVoltageLowThresholdNotificationcurrentThe hpnicfEntityExtVoltageLowThresholdNotification indicates the voltage is lower than the threshold. If the voltage is lower too much than the entity needs, t…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.3NotificationhpnicfEntityExtVoltageHighThresholdNotificationcurrentThe hpnicfEntityExtVoltageHighThresholdNotification indicates the voltage is higher than the threshold. If the voltage is higher too much than the entity needs…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.4NotificationhpnicfEntityExtCpuUsageThresholdNotficationcurrentThe hpnicfEntityExtCpuUsageThresholdNotfication indicates the entity is overloaded.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.5NotificationhpnicfEntityExtMemUsageThresholdNotificationcurrentThe hpnicfEntityExtMemUsageThresholdNotification indicates the entity is overloaded.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.6NotificationhpnicfEntityExtOperEnabledcurrentThe trap indicates the entity is operable at present.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.7NotificationhpnicfEntityExtOperDisabledcurrentThe trap indicates the entity is not operable at present.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.8NotificationhpnicfEntityExtCriticalTemperatureThresholdNotificationcurrentThe hpnicfEntityExtCriticalTemperatureThresholdNotification indicates the temperature exceeds the critical temperature. In this condition, user should check th…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.9NotificationhpnicfEntityExtSFPAlarmOncurrentThe trap is generated when the SFP module fails or runs abnormally for some particular reason.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.10NotificationhpnicfEntityExtSFPAlarmOffcurrentThe trap is generated when the SFP module restores to normal status.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.11NotificationhpnicfEntityExtSFPPhonycurrentThis module is NOT sold by authorized manufacturer. The normal function of the device or assume the maintenance responsibility thereof will NOT be guaranteed. …
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.12NotificationhpnicfEntityInsertcurrentThe trap is generated when a removable entity inserting to device.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.13NotificationhpnicfEntityRemovecurrentThe trap is generated when a removable entity removing from device.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.14NotificationhpnicfEntityExtForcedPowerOffcurrentThe trap indicates the entity is forced to power off.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.15NotificationhpnicfEntityExtForcedPowerOncurrentThe trap indicates the entity is forced to power on.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.16NotificationhpnicfEntityExtFaultAlarmOncurrentThe trap indicates a fault occurs on the specified entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.17NotificationhpnicfEntityExtFaultAlarmOffcurrentThe trap indicates a fault disappears on the specified entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.18NotificationhpnicfEntityExtResourceLackcurrentThe trap indicates that a kind of resource is not enough on the specified entity.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.19NotificationhpnicfEntityExtResourceEnoughcurrentThe trap indicates that the entity recovers from the status of no enough resource.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.20NotificationhpnicfEntityExtTemperatureLowercurrentThe trap indicates the temperature of a specified entity is under the lower threshold. In this condition, user should check the status and the environment of t…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.21NotificationhpnicfEntityExtTemperatureTooUpcurrentThe trap indicates the temperature of a specified entity exceeded the shutdown threshold. In this condition, user should check the status and the environment o…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.22NotificationhpnicfEntityExtTemperatureNormalcurrentThe trap indicates the temperature of a specified entity recover from abnormal status.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.23NotificationhpnicfEntityExternalAlarmOccurcurrentThe trap is generated when the monitored device connected to the specified entity fails.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.24NotificationhpnicfEntityExternalAlarmRecovercurrentThe trap is generated when the failed device connected to the specified entity returns to normal.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.25NotificationhpnicfEntityExtCpuUsageThresholdRecovercurrentThe trap indicates the CPU usage descends the threshold.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.26NotificationhpnicfEntityExtMemUsageThresholdRecovercurrentThe trap indicates the memory usage descends the threshold.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.27NotificationhpnicfEntityExtMemAllocatedFailedcurrentThe trap indicates the memory allocated failed.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.28NotificationhpnicfEntityExtECCParityAlarmcurrentThe trap indicates the ECC(Error Correction Code) parity error alarm.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.29NotificationhpnicfEntityExtCritLowerTempThresholdNotificationcurrentThe hpnicfEntityExtCritLowerTempThresholdNotification indicates the temperature is lower than the threshold. If the temperature is lower too much than the enti…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.30NotificationhpnicfEntityExtTemperatureTooLowcurrentThe hpnicfEntityExtTemperatureTooLow indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the ent…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.31NotificationhpnicfEntityExtFanDirectionNotPreferredcurrentThis trap indicates the specified fan's direction does not accord with preferred. The two parameters indicate the entity index and physical name of fan.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.32NotificationhpnicfEntityExtFanDirectionNotAccordcurrentThis trap indicates the direction of fans does not accord with each other. The two parameters indicate the parent entity of the fans.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.33NotificationhpnicfEntityExtSFPInvalidcurrentThe transceiver module is not compatible with the interface card. The authorized manufacturer therefore shall NOT guarantee the normal function of the transcei…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.34NotificationhpnicfEntityExtSFPInvalidNowcurrentThis transceiver module is not compatible with the interface card. The authorized manufacturer therefore shall NOT guarantee the normal function of the transce…
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.35NotificationhpnicfEntityExtMemUsageThresholdOverTrapcurrentThis trap indicates that the memory usage of the entity is overloaded. This trap is used to replace hpnicfEntityExtMemUsageThresholdNotification.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.36NotificationhpnicfEntityExtMemUsageThresholdRecoverTrapcurrentThis trap indicates that the memory usage decreased below the threshold. This trap is used to replace hpnicfEntityExtMemUsageThresholdRecover.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.37NotificationhpnicfEntityExtVoltageNormalcurrentThis trap indicates that the voltage recovers to normal.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.38NotificationhpnicfEntityExtVoltageLowercurrentThis trap indicates that the voltage is lower than the low threshold.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.39NotificationhpnicfEntityExtVoltageTooLowcurrentThis trap indicates that the voltage is lower than the fatal low threshold.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.40NotificationhpnicfEntityExtVoltageHighercurrentThis trap indicates that the voltage is higher than the high threshold.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.41NotificationhpnicfEntityExtVoltageTooHighcurrentThis trap indicates that the voltage is higher than the fatal high threshold.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.1NodehpnicfEntityExtTrapsInfor
1.3.6.1.4.1.11.2.14.11.15.2.6.2.1.1ScalarhpnicfEntityExtTrapDescriptionaccessible-for-notifycurrentThe information of trap.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.1.2ScalarhpnicfEntityExtECCParityAlarmStatusaccessible-for-notifycurrentECC parity error.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.1.3ScalarhpnicfEntityExtSFPInvalidInDaysaccessible-for-notifycurrentThe days when the transceiver module is still valid, but after those days, it will be invalidated.
1.3.6.1.4.1.11.2.14.11.15.2.6.2.1.4ScalarhpnicfEntityExtFirstTrapTimeaccessible-for-notifycurrentRepresents the first trap time.
1.3.6.1.4.1.11.2.14.11.15.2.6.3NodehpnicfEntityExtConformance
1.3.6.1.4.1.11.2.14.11.15.2.6.3.1NodehpnicfEntityExtCompliances
1.3.6.1.4.1.11.2.14.11.15.2.6.3.1.1CompliancehpnicfEntityExtComplianceread-onlycurrentThe compliance statement for systems supporting this MIB.
1.3.6.1.4.1.11.2.14.11.15.2.6.3.2NodehpnicfEntityExtGroups
1.3.6.1.4.1.11.2.14.11.15.2.6.3.2.1GrouphpnicfEntityExtGroupcurrentEntity Extend group.
1.3.6.1.4.1.11.2.14.11.15.2.6.3.2.2GrouphpnicfEntityExtNotificationGroupcurrentEntity Extend Notification group.
1.3.6.1.4.1.11.2.14.11.15.2.6.3.2.3GrouphpnicfEntityExtManuGroupcurrentStandard Device Manufacture Information group.
1.3.6.1.4.1.11.2.14.11.15.2.6.3.2.4GrouphpnicfEntityExtPowerGroupcurrentStandard Entity Power Information group.
Type Definitions
NameSyntaxStatusDescription
HpnicfAdminStateINTEGER { notSupported(1), locked(2), shuttingDown(3), unlocked(4) }currentThe administrative state for this object, and it is possible to set the state when needed. A value of locked means the resource is administratively prohibited from use. A value of shuttingDown means that usage is admini…
HpnicfAlarmStatusBITS { notSupported (0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning (6), indeterminate (7) }currentRepresents the possible values of alarm status. When no bits of this attribute are set, then none of the status conditions described below are present. When the value of under repair is set, the resource is currently be…
HpnicfOperStateINTEGER { notSupported (1), disabled(2), enabled(3), dangerous(4) }currentRepresents the possible values of operational states. A value of disabled means the resource is totally inoperable. A value of enabled means the resource is partially or fully operable.
HpnicfStandbyStatusINTEGER { notSupported (1), hotStandby(2), coldStandby(3), providingService(4) }currentRepresents the possible values of standby status. A value of hotStandby means the resource is not providing service, but is will be immediately able to take over the role of the resource to be backed-up, without the nee…