MIB Viewer

HPNSACAGE-MIB

40 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC1155-SMIenterprises
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.11Nodehp
1.3.6.1.4.1.11.2Nodenm
1.3.6.1.4.1.11.2.23Nodehpnsa
1.3.6.1.4.1.11.2.23.28NodehpCageAgt
1.3.6.1.4.1.11.2.23.28.1ScalarhpCageAgtVersionread-onlymandatoryThe current version (major) number of the SNMP agent.
1.3.6.1.4.1.11.2.23.28.2ScalarhpCageAgtRevisionread-onlymandatoryThe current revision (minor) number of the SNMP agent.
1.3.6.1.4.1.11.2.23.28.3ScalarhpCageAgtMibVersionread-onlymandatoryThe current version (major) number of the SNMP agent's MIB.
1.3.6.1.4.1.11.2.23.28.4ScalarhpCageAgtMibRevisionread-onlymandatoryThe current revision (minor) number of the SNMP agent's MIB.
1.3.6.1.4.1.11.2.23.28.5ScalarhpCageAgtnDrieCagesread-onlymandatoryThe number of Starfish drive cages present on the system.
1.3.6.1.4.1.11.2.23.28.6ScalarhpCageAgtcbDriveCageInforead-onlymandatoryThe number of bytes required to represent the drive cage information struucture.
1.3.6.1.4.1.11.2.23.28.7ScalarhpCageAgtDriveCageInforead-onlymandatoryThe drive cage information structure, defining the state and addresses of each drive bay.
1.3.6.1.4.1.11.2.23.28.8ScalarhpCageAgtDriveCageStatusread-onlymandatoryThe result of the last query operation for drive cage data. This value is set by querying the hpCageAgtDriveCageInfo object.
1.3.6.1.4.1.11.2.23.28.9ScalarhpCageAgtFlashAdptrTyperead-writemandatoryThe type of adapter to be flashed. This must be set prior to setting the flash count.
1.3.6.1.4.1.11.2.23.28.10ScalarhpCageAgtFlashAdptrNumread-writemandatoryThe adapter number to be flashed. This must be set prior to setting the flash count.
1.3.6.1.4.1.11.2.23.28.11ScalarhpCageAgtChannelNumread-writemandatoryThe channel number to be flashed. This must be set prior to setting the flash count.
1.3.6.1.4.1.11.2.23.28.12ScalarhpCageAgtFlashCountwrite-onlymandatoryThe number of times to activate the flashing of the LEDs. (See members 9, 10, and 11.)
1.3.6.1.4.1.11.2.23.28.13ScalarhpCageAgtFlashStatusread-onlymandatoryThe resulting status of the last setting of the flash count operation. If this value is 99999999, then the operation is still pending.
1.3.6.1.4.1.11.2.23.28.14ScalarhpCageAgtnDrivesread-onlymandatoryThe number of hot-swap drives present on the system. Requery the nDriveCages field to recalculate this field.
1.3.6.1.4.1.11.2.23.28.15TablehpCageAgtDriveTablenot-accessiblemandatoryA list of the hot-swap drives present on the system.
1.3.6.1.4.1.11.2.23.28.15.1RowhpCageAgtDriveEntrynot-accessiblemandatory
1.3.6.1.4.1.11.2.23.28.15.1.1ColumnhpCageAgtDriveIndexread-onlymandatoryThe index number of the drive.
1.3.6.1.4.1.11.2.23.28.15.1.2ColumnhpCageAgtDriveI2cAddrread-onlymandatoryThe IIC (I-square-C) bus address of the drive.
1.3.6.1.4.1.11.2.23.28.15.1.3ColumnhpCageAgtDriveScsiIDread-onlymandatoryThe SCSI target ID of the drive (unique to the IIC bus).
1.3.6.1.4.1.11.2.23.28.15.1.4ColumnhpCageAgtDriveLEDStateread-writemandatoryThe state of the drive LED, which can be set to amber (on).
1.3.6.1.4.1.11.2.23.28.15.1.5ColumnhpCageAgtDriveLEDSetStatusread-onlymandatoryThe result of the last LED state change operation for this drive.
1.3.6.1.4.1.11.2.23.28.15.1.6ColumnhpCageAgtDrivePresentread-onlymandatoryIs a drive present in this drive cage bay?
1.3.6.1.4.1.11.2.23.28.15.1.7ColumnhpCageAgtCageChannelread-onlymandatoryThe channel number on the SCSI adapter to which this cage is connected.
1.3.6.1.4.1.11.2.23.28.15.1.8ColumnhpCageAgtCageAdapterread-onlymandatoryThe port number of the SCSI adapter to which this cage is connected.
1.3.6.1.4.1.11.2.23.28.15.1.9ColumnhpCageAgtCageTyperead-onlymandatoryThe type of the hot-swap cage.
1.3.6.1.4.1.11.2.23.28.16ScalarhpCageAgtTargetIDread-writemandatoryThe channel number to be flashed. This must be set prior to setting the flash count.
1.3.6.1.4.1.11.2.23.28.17ScalarhpCageAgtFlashOneCountwrite-onlymandatoryThe number of times to activate the flashing of one LED. (See members 9, 10, 11, and 16.)
1.3.6.1.4.1.11.2.23.28.18ScalarhpCageAgtFWStatusread-onlymandatoryThe resulting status of the last firmware update operation. If this value is 99999999, then the operation is still pending.
1.3.6.1.4.1.11.2.23.28.19ScalarhpCageAgtUpdateDriveFWwrite-onlymandatorySet this value to the key 746E654Bh to begin updating firmware on drive indicated in SCSI ID. (See members 9, 10, 11, and 16.)
1.3.6.1.4.1.11.2.23.28.20ScalarhpCageAgtDriveReadinessread-onlymandatoryDetermine the state of readiness for the drive. (See members 9, 10, 11, and 16.)
1.3.6.1.4.1.11.2.23.28.21ScalarhpCageAgtDownloadWwwUrlread-writemandatorySet this value to the URL to begin downloading. Check member 21 for progress and 22 for status.
1.3.6.1.4.1.11.2.23.28.22ScalarhpCageAgtDownloadSizeread-onlymandatoryCurrent size (in bytes) of the amount of data downloaded for this file. If less than 10 bytes reported, size is actually state info: (0 = no download, 1 = down…
1.3.6.1.4.1.11.2.23.28.23ScalarhpCageAgtDownloadStatusread-onlymandatoryThe resulting status of the most recent (or current) WWW download operation. If this value is 99999999, then the operation is still pending.
1.3.6.1.4.1.11.2.23.28.24ScalarhpCageAgtDownloadProxyread-writemandatorySet this value to the WWW proxy server spec (eg: WWW_PROXY.XXX.COM:8088).
1.3.6.1.4.1.11.2.23.28.25ScalarhpCageAgtFormatDrivewrite-onlymandatorySet this value to the key 6B72614Dh to begin formatting drive indicated in SCSI ID. (See members 9, 10, 11, and 16.)
1.3.6.1.4.1.11.2.23.28.26ScalarhpCageAgtFormatStatusread-writemandatoryThe resulting status of the last formatoperation. If this value is 99999999, then the operation is still pending. If 99999990, then user input is pending allow…