MIB Viewer

HPVCMODULE-MIB

54 objects
This MIB module describes module specific MIB objects present in each of the Virtual Connect Ethernet (VC-Enet) Modules. These objects represent information about individual VC-Enet modules irrespective of its VC domain role.
OIDNameAccessStatusDescription
1.3.6.1.4.1.11Nodehp
1.3.6.1.4.1.11.5NodehpSysMgt
1.3.6.1.4.1.11.5.7NodehpEmbeddedServerMgt
1.3.6.1.4.1.11.5.7.5NodehpModuleMgmtProc
1.3.6.1.4.1.11.5.7.5.2NodevirtualConnect
1.3.6.1.4.1.11.5.7.5.2.3IdentityvcModuleMIBThis MIB module describes module specific MIB objects present in each of the Virtual Connect Ethernet (VC-Enet) Modules. These objects represent information ab…
1.3.6.1.4.1.11.5.7.5.2.3.1NodevcModuleMIBObjects
1.3.6.1.4.1.11.5.7.5.2.3.1.1NodevcModuleObjects
1.3.6.1.4.1.11.5.7.5.2.3.1.1.1ScalarvcModuleDomainNameread-onlycurrentThe administratively assigned name of the Virtual Connect Domain associated with this module.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.2ScalarvcModuleRoleread-onlycurrentThe VC domain role of this VC module.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.3ScalarvcModuleDomainPrimaryAddressTyperead-onlycurrentThe transport address type used to address the primary VC module.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.4ScalarvcModuleDomainPrimaryAddressread-onlycurrentThe address of the primary VC module. The address format is determined by the vcDomainPrimaryAddressType object.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.5ScalarvcModuleEnclosureRoleread-onlycurrentThe VC enclosure role of the enclosure VC module.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.6TablevcModulePortTablenot-accessiblecurrentA table that contains VC specific information about every port that is associated with this bridge.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1RowvcModulePortEntrynot-accessiblecurrentVC specific information for each port of the bridge.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1.1ColumnvcModulePortread-onlycurrentThe port number of the port for which this entry contains management information.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1.2ColumnvcModulePortIfIndexread-onlycurrentThe value of the instance of the ifIndex object, defined in IF-MIB, for the interface corresponding to this port. A zero value indicates ifIndex is not availab…
1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1.3ColumnvcModulePortBpduLoopStatusread-onlycurrentThe BPDU loop detection status for this port.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.6.1.4ColumnvcModulePortProtectionStatusread-onlycurrentThe port protection status for this port.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.7ScalarvcModuleDomainPrimaryAddressIpv6read-onlycurrentThe IPv6 address of the primary VC module.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.8ScalarvcSwitchMemParityErrorCountread-onlycurrentParity errors detected on switch's internal memory. This counter is incremented whenever switch software detects and corrects parity error.
1.3.6.1.4.1.11.5.7.5.2.3.1.1.9ScalarvcSwitchMemParityErrorNonCorrectableCountread-onlycurrentParity/ECC errors detected on switch's internal memory. This counter is incremented whenever switch software detects non correctable parity/ECC error.
1.3.6.1.4.1.11.5.7.5.2.3.2NodevcModuleMIBNotificationPrefix
1.3.6.1.4.1.11.5.7.5.2.3.2.0NodevcModuleMIBNotifications
1.3.6.1.4.1.11.5.7.5.2.3.2.0.1NotificationvcModuleDomainRoleChangecurrentThe VCM role of the VC module has changed.
1.3.6.1.4.1.11.5.7.5.2.3.2.0.2NotificationvcSwitchMemParityErrorEventcurrentThe switch hardware has detected a parity error. The parity error is automatically corrected.
1.3.6.1.4.1.11.5.7.5.2.3.2.0.3NotificationvcSwitchMemParityErrorNonCorrectableEventcurrentThe switch hardware has detected a parity/ECC error. The parity/ecc error is non Correctable. cpqHoFwVerLocation identifies the Rack, Enclosurename and Bay num…
1.3.6.1.4.1.11.5.7.5.2.3.2.0.11NotificationvcModPortInputUtilizationUpcurrentThe port input utilization rate has exceeded high threshold. The input line utilization on a port has exceeded its threshold for longer than the threshold aver…
1.3.6.1.4.1.11.5.7.5.2.3.2.0.12NotificationvcModPortInputUtilizationDowncurrentThe port input utilization rate has dropped below low watermark. The input line utilization on a port has dropped below its low watermark for longer than the t…
1.3.6.1.4.1.11.5.7.5.2.3.2.0.13NotificationvcModPortOutputUtilizationUpcurrentThe port output utilization rate has exceeded high threshold. The output line utilization on a port has exceeded its high watermark for longer than the thresho…
1.3.6.1.4.1.11.5.7.5.2.3.2.0.14NotificationvcModPortOutputUtilizationDowncurrentThe port output utilization rate has dropped below low watermark. The output line utilization on a port has dropped below its low watermark for longer than the…
1.3.6.1.4.1.11.5.7.5.2.3.2.0.15NotificationvcModPortInputErrorsUpcurrentThe input error count on a port has exceeded high watermark. The input error count on a port has exceeded its high watermark for longer than the error averagin…
1.3.6.1.4.1.11.5.7.5.2.3.2.0.16NotificationvcModPortInputErrorsDowncurrentThe input error count on a port has dropped below low watermark. The input error count on a port has dropped below its low watermark for longer than the error …
1.3.6.1.4.1.11.5.7.5.2.3.2.0.17NotificationvcModPortOutputErrorsUpcurrentThe output error count on a port has exceeded its high watermark. The output error count on a port has exceeded its high watermark for longer than the error av…
1.3.6.1.4.1.11.5.7.5.2.3.2.0.18NotificationvcModPortOutputErrorsDowncurrentThe output error count on a port has dropped below its low watermark. The output error count on a port has dropped below its low watermark for longer than the …
1.3.6.1.4.1.11.5.7.5.2.3.2.0.19NotificationvcModPortBpduLoopDetectedcurrentA BPDU loop condition is detected on this port. If the port is configured for loop protection, the port is disabled to protect against network loops. The port …
1.3.6.1.4.1.11.5.7.5.2.3.2.0.20NotificationvcModPortBpduLoopClearedcurrentA previous BPDU loop condition is cleared. This trap is only sent when the agent detects transition from 'loop detected' state to 'ok' state on a given port.
1.3.6.1.4.1.11.5.7.5.2.3.2.0.21NotificationvcModPortProtectionConditionDetectedcurrentA port protection condition is detected on this port. If the new port protection status is a value other than ok, the port may be disabled to protect the VC mo…
1.3.6.1.4.1.11.5.7.5.2.3.2.0.22NotificationvcModPortProtectionConditionClearedcurrentPort is recovered from port protection condition. The port is recovered from port protection condition to normal operational state.
1.3.6.1.4.1.11.5.7.5.2.3.2.1NodevcModuleMIBNotificationObjects
1.3.6.1.4.1.11.5.7.5.2.3.3NodevcModuleMIBConformance
1.3.6.1.4.1.11.5.7.5.2.3.3.1NodevcModuleMIBCompliances
1.3.6.1.4.1.11.5.7.5.2.3.3.1.1CompliancevcModuleMIBCompliancedeprecatedThe compliance statement for entities which implement the VC MIB.
1.3.6.1.4.1.11.5.7.5.2.3.3.1.2CompliancevcModuleMIBCompliance2currentThe compliance statement for entities which implement the VC MIB.
1.3.6.1.4.1.11.5.7.5.2.3.3.2NodevcModuleMIBGroups
1.3.6.1.4.1.11.5.7.5.2.3.3.2.1GroupvcModuleGroupdeprecatedVirtual Connect Module objects.
1.3.6.1.4.1.11.5.7.5.2.3.3.2.2GroupvcModPortThresholdNotificationsGroupcurrentThe notifications which indicate specific changes in the Virtual Connect port utilization status.
1.3.6.1.4.1.11.5.7.5.2.3.3.2.3GroupvcModPortStatusNotificationsGroupcurrentThe notifications which indicate specific changes in the Virtual Connect port operational status.
1.3.6.1.4.1.11.5.7.5.2.3.3.2.4GroupvcModuleGroup2currentVirtual Connect Module objects.
Type Definitions
NameSyntaxStatusDescription
VcEnclosureRoleINTEGER { unknown(1), primary(2), secondary(3) }currentThe virtual connect operational role of the enclosure associated with with this module. The enumerations are described below: unknown - The enclosure role is unknown because of one of the following reasons, - The enclos…
VcModulePortBpduLoopStatusINTEGER { ok(1), loop-detected(2) }currentThe BPDU loop detection status of a VcModulePort. The enumerations are described below: ok - The port is operating normal. loop-detected - BPDU loop detected on this port.
VcModulePortProtectionStatusINTEGER { ok(1), pause-flood-detected(2), in-pause-condition(3) }currentThe port protection status of the VcModulePort. Port protection features provide protection against denial of service conditions caused by external entities. The enumerations are described below: ok - The port is operat…
VcModuleRoleINTEGER { unintegrated(1), primaryProtected(2), primaryUnprotected(3), standby(4), other(5) }currentThe virtual connect operational role of this module. The enumerations are described below: unintegrated - module is not a member of a domain primaryProtected - module is VCM primary, and a VCM standby exists primaryUnpr…
VcModuleTypeINTEGER { vcModuleEnet(1), vcModuleFC(2), vcModuleOther(3) }currentThe virtual connect interconnect module type. The enumerations are described below: vcModuleEnet - VC-Enet module vcModuleFC - VC-FC module vcModuleOther - Unknown module or a module not supported by VC