HUAWEI-ENERGYMNGT-MIB
65 objects
huawei energy management MIB.
Imported Objects
| HUAWEI-MIB | huaweiUtility |
| INET-ADDRESS-MIB | InetAddress InetAddressType |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter64 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DateAndTime DisplayString RowStatus TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.6.157 | IdentityhwEnergyMngt | huawei energy management MIB. | ||
| 1.3.6.1.4.1.2011.6.157.1 | NodehwSysPowerMgnt | |||
| 1.3.6.1.4.1.2011.6.157.1.1 | ScalarhwPowerConsumption | read-only | current | NE total power consumption, counted from equipment first used. Joule(Watt * second). Note: If the device is a power supplier(PSE), the power consumption includ… |
| 1.3.6.1.4.1.2011.6.157.1.2 | ScalarhwPowerStatPeriod | read-write | current | NE power statistics period: fifteenMinutes(1): The power statistics generated every 15 minutes. thirtyMinutes(2): The power statistics generated every 30 minut… |
| 1.3.6.1.4.1.2011.6.157.1.3 | ScalarhwAveragePower | read-only | current | NE average power consumtion during a period: milliwatt |
| 1.3.6.1.4.1.2011.6.157.1.4 | ScalarhwRatedPower | read-only | current | NE rated power: milliwatt |
| 1.3.6.1.4.1.2011.6.157.1.5 | ScalarhwThresholdOfPower | read-write | current | NE threshold power: milliwatt |
| 1.3.6.1.4.1.2011.6.157.1.6 | ScalarhwCurrentPower | read-only | current | NE current power: milliwatt |
| 1.3.6.1.4.1.2011.6.157.1.7 | ScalarhwPoEType | read-only | current | powered type: PSE(1): power supplier. PD(2): powered deivce. noPoe(255): not PSE or PD |
| 1.3.6.1.4.1.2011.6.157.1.8 | ScalarhwPSEPower | read-only | current | The output power(milliwatt) by a PSE. For a non-PSE device, the value is zero. |
| 1.3.6.1.4.1.2011.6.157.2 | NodehwBoardPowerMngt | |||
| 1.3.6.1.4.1.2011.6.157.2.1 | TablehwBoardPowerMngtTable | not-accessible | current | This table describes current power and rated power of boards. The index is hwBoardIndex. |
| 1.3.6.1.4.1.2011.6.157.2.1.1 | RowhwBoardPowerMngtEntry | not-accessible | current | The entry of hwBoardPowerMngtTable. |
| 1.3.6.1.4.1.2011.6.157.2.1.1.1 | ColumnhwBoardIndex | read-only | current | Index: reserved/shelf/frame/slot. The index is format by 4 bytes(8bit for 1 byte): reservedByte(0xFF), shelfID, frameID, slotID. e.g. shlef=1, frame=2, slot=17… |
| 1.3.6.1.4.1.2011.6.157.2.1.1.2 | ColumnhwBoardType | read-only | current | hwBoardType describes main type of board. |
| 1.3.6.1.4.1.2011.6.157.2.1.1.3 | ColumnhwBoardName | read-only | current | hwBoardName describes full name of board. |
| 1.3.6.1.4.1.2011.6.157.2.1.1.4 | ColumnhwBoardCurrentPower | read-only | current | current power of board(slot): milliwatt |
| 1.3.6.1.4.1.2011.6.157.2.1.1.5 | ColumnhwBoardRatedPower | read-only | current | rated power of board(slot): milliwatt |
| 1.3.6.1.4.1.2011.6.157.2.1.1.6 | ColumnhwBoardThresholdOfPower | read-write | current | Threshold power of board(slot): milliwatt |
| 1.3.6.1.4.1.2011.6.157.3 | NodehwEnergySavingMngt | |||
| 1.3.6.1.4.1.2011.6.157.3.1 | ScalarhwEnergySavingMode | read-write | current | Power saving mode: UserDefined(1): UserDined energy-saving mode, user can define energy-saving strategy. Standard(2): standard energy-saving mode Basic(3): bas… |
| 1.3.6.1.4.1.2011.6.157.3.2 | TablehwEnergySavingMethodTable | not-accessible | current | hwEnergySavingMethodTable defines energy-saving Method for all mode. User can set a method with its parameter. The index of this table is hwEnergySavingMethodI… |
| 1.3.6.1.4.1.2011.6.157.3.2.1 | RowhwEnergySavingMethodEntry | not-accessible | current | Entry of energy-saveing method table. |
| 1.3.6.1.4.1.2011.6.157.3.2.1.1 | ColumnhwEnergySavingMethodIndex | read-only | current | The index of method in use. |
| 1.3.6.1.4.1.2011.6.157.3.2.1.2 | ColumnhwEnergySavingMethodEnable | read-write | current | hwEnergySaveingMethodEnable describes the status of energy-saving method: enableed or disabled. |
| 1.3.6.1.4.1.2011.6.157.3.3 | TablehwEnergySavingParameterTable | not-accessible | current | hwEnergySavingParameterTable defines parameters for all energy-saving methods. User can set parameter for a method. The index of this table: hwEnergySavingMeth… |
| 1.3.6.1.4.1.2011.6.157.3.3.1 | RowhwEnergySavingParameterEntry | not-accessible | current | Entry of energy-saveing parameter table. |
| 1.3.6.1.4.1.2011.6.157.3.3.1.1 | ColumnhwEnergySavingParameterIndex | read-only | current | The second index of hwEnergySavingParameterTable. An energy-saving method might have more than one parameter. This index is used to identify the parameter for … |
| 1.3.6.1.4.1.2011.6.157.3.3.1.2 | ColumnhwEnergySavingParameterValue | read-write | current | The value of an energy-saveing method's parameter. The parameter is a format string. When NMS sets integer 12 as a parameter for a energy-saving method, the va… |
| 1.3.6.1.4.1.2011.6.157.3.4 | TablehwEnergySavingCapabilityMngtTable | not-accessible | current | This table describes the energy-saving capability, including energy-saving methods and parameters. The index is hwEnergySavingCapabilityDescIndex. |
| 1.3.6.1.4.1.2011.6.157.3.4.1 | RowhwEnergySavingCapabilityMngtEntry | not-accessible | current | The entry of hwBoardPowerMngtTable. |
| 1.3.6.1.4.1.2011.6.157.3.4.1.1 | ColumnhwEnergySavingCapabilityDescIndex | read-only | current | The index of hwEnergySavingCapabilityMngtTable. |
| 1.3.6.1.4.1.2011.6.157.3.4.1.2 | ColumnhwEnergySavingCapabilityDescLanguage | read-only | current | The language of EnergySavingCapabilityDescription file. 'en-gb'(English-GreatBraitain) 'zh-cn'(Chinese) |
| 1.3.6.1.4.1.2011.6.157.3.4.1.3 | ColumnhwEnergySavingCapabilityDesc | read-only | current | User can get the description string from hwEnergySavingCapabilityDesc. An XML file which is compressed by ZIP to less than 10240 bytes, describes the energy-sa… |
| 1.3.6.1.4.1.2011.6.157.3.5 | ScalarhwEnergySavingDescReqMode | read-only | current | The mode describes how to get energy saving capability description file : snmp(1): Get the file using hwEnergySavingCapabilityDesc. ftp(2): Get the file using … |
| 1.3.6.1.4.1.2011.6.157.4 | NodehwEnergyFtpcObjects | |||
| 1.3.6.1.4.1.2011.6.157.4.1 | TablehwEnergyFtpcTransFileTable | not-accessible | current | This table is used to configure transfer file feature related parameters. |
| 1.3.6.1.4.1.2011.6.157.4.1.1 | RowhwEnergyFtpcTransFileEntry | not-accessible | current | Name identifying Transfer configuration |
| 1.3.6.1.4.1.2011.6.157.4.1.1.1 | ColumnhwEnergyFtpcSetName | not-accessible | current | Name identifying FTPC Transfer configuration |
| 1.3.6.1.4.1.2011.6.157.4.1.1.2 | ColumnhwEnergyFtpcSrcAddrType | read-create | current | Source IP address Type: ipv4(1) ipv6(2) |
| 1.3.6.1.4.1.2011.6.157.4.1.1.3 | ColumnhwEnergyFtpcSrcAddr | read-create | current | Source IP address |
| 1.3.6.1.4.1.2011.6.157.4.1.1.4 | ColumnhwEnergyFtpcVpnName | read-create | current | VPN name used for the corresponding connection |
| 1.3.6.1.4.1.2011.6.157.4.1.1.5 | ColumnhwEnergyFtpcHostAddrType | read-create | current | Server address type: ipv4(1) ipv6(2) |
| 1.3.6.1.4.1.2011.6.157.4.1.1.6 | ColumnhwEnergyFtpcHostAddr | read-create | current | Server IP address |
| 1.3.6.1.4.1.2011.6.157.4.1.1.7 | ColumnhwEnergyFtpcServerPort | read-create | current | Server port used for connection |
| 1.3.6.1.4.1.2011.6.157.4.1.1.8 | ColumnhwEnergyFtpcUserName | read-create | current | User Name used for user validation |
| 1.3.6.1.4.1.2011.6.157.4.1.1.9 | ColumnhwEnergyFtpcPassword | read-create | current | Password used for user validation. Password Length while setting should not be more than 16 characters, while querying password will be cipher text |
| 1.3.6.1.4.1.2011.6.157.4.1.1.10 | ColumnhwEnergyFtpcDirectory | read-create | current | Local working directory |
| 1.3.6.1.4.1.2011.6.157.4.1.1.11 | ColumnhwEnergyFtpcSrcIfName | read-create | current | Interface Name |
| 1.3.6.1.4.1.2011.6.157.4.1.1.12 | ColumnhwEnergyFtpcTransCfgRowStatus | read-create | current | The object specifies the status of this table entry. When the status is createAndGo, it allows to create and when value is destroy it allows to delete the reco… |
| 1.3.6.1.4.1.2011.6.157.4.1.1.13 | ColumnhwEnergyFtpcAction | read-write | current | The type of request. get(1): To request a file from the FTP server. put(2): To send a file to the FTP server. |
| 1.3.6.1.4.1.2011.6.157.4.1.1.14 | ColumnhwEnergyFtpcTransMode | read-write | current | The file transfer protocol. Default: FTP. |
| 1.3.6.1.4.1.2011.6.157.4.1.1.15 | ColumnhwEnergyFtpOperStatus | read-only | current | The OperStatus: opInProgress(1): the operation is in process. opSuccess(2): the operation has been completed successfully. opInvalid(3): the command is invalid… |
| 1.3.6.1.4.1.2011.6.157.6 | NodehwEnergyConformance | |||
| 1.3.6.1.4.1.2011.6.157.6.1 | NodehwEnergyCompliances | |||
| 1.3.6.1.4.1.2011.6.157.6.1.1 | CompliancehwEnergyCompliance | current | Description. | |
| 1.3.6.1.4.1.2011.6.157.6.2 | NodehwEnergyGroups | |||
| 1.3.6.1.4.1.2011.6.157.6.2.1 | GrouphwEnergyFtpcGroup | current | Description. | |
| 1.3.6.1.4.1.2011.6.157.6.2.2 | GrouphwSysPowerMgntGroup | current | Description. | |
| 1.3.6.1.4.1.2011.6.157.6.2.3 | GrouphwEnergySavingMngtGroup | current | Description. | |
| 1.3.6.1.4.1.2011.6.157.6.2.4 | GrouphwEnergyNotificationGroup | current | Description. | |
| 1.3.6.1.4.1.2011.6.157.10 | NodehwEnergyTrapObjects | |||
| 1.3.6.1.4.1.2011.6.157.10.1 | ScalarhwEnergyDevId | accessible-for-notify | current | This object identifies the device ID. |
| 1.3.6.1.4.1.2011.6.157.11 | NodehwEnergyNotification | |||
| 1.3.6.1.4.1.2011.6.157.11.1 | NotificationhwEnergyDevChangeToSleep | current | This notification indicates device entering in the sleeping status. |