MIB Viewer

HUAWEI-PERFORMANCE-MIB

27 objects
This mib is supplementary for RMON-MIB(rfc2819). It includes only one table. The mib defines two new objects. One is to set the alarm object by expression, the other is to limit the existing time of an alarm row. notices.
Imported Objects
HUAWEI-MIBhwInternetProtocol
IF-MIBOwnerString
RFC1213-MIBDisplayString
RMON-MIBEntryStatus
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIInteger32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.1.3.4NodermonExtend
1.3.6.1.4.1.2011.1.3.4.0IdentityrmonExtendEventsV2currentDefinition point for pri RMON notifications.
1.3.6.1.4.1.2011.1.3.4.0.1NotificationpririsingAlarmcurrentThe SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps.
1.3.6.1.4.1.2011.1.3.4.0.2NotificationprifallingAlarmcurrentThe SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps.
1.3.6.1.4.1.2011.1.3.4.4IdentityperformanceThis mib is supplementary for RMON-MIB(rfc2819). It includes only one table. The mib defines two new objects. One is to set the alarm object by expression, the…
1.3.6.1.4.1.2011.1.3.4.4.1TableprialarmTablenot-accessiblecurrentA list of alarm entries.
1.3.6.1.4.1.2011.1.3.4.4.1.1RowprialarmEntrynot-accessiblecurrentA list of parameters that set up a periodic checking for alarm conditions. For example, an instance of the alarmValue object might be named alarmValue.8
1.3.6.1.4.1.2011.1.3.4.4.1.1.1ColumnprialarmIndexread-onlycurrentAn index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device.
1.3.6.1.4.1.2011.1.3.4.4.1.1.2ColumnprialarmIntervalread-createcurrentThe interval in seconds over which the data is sampled and compared with the rising and falling thresholds. When setting this variable, care should be taken in…
1.3.6.1.4.1.2011.1.3.4.4.1.1.3ColumnprialarmVariableread-createcurrentThe object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, Counter3…
1.3.6.1.4.1.2011.1.3.4.4.1.1.4ColumnprialarmSympolread-createcurrentThe string which the alarm line described.
1.3.6.1.4.1.2011.1.3.4.4.1.1.5ColumnprialarmSampleTyperead-createcurrentThe method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of this object is absoluteValue(1), …
1.3.6.1.4.1.2011.1.3.4.4.1.1.6ColumnprialarmValueread-onlycurrentThe value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value will be the difference between the sample…
1.3.6.1.4.1.2011.1.3.4.4.1.1.7ColumnprialarmStartupAlarmread-createcurrentThe alarm that may be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater than or equal to the risingThre…
1.3.6.1.4.1.2011.1.3.4.4.1.1.8ColumnprialarmRisingThresholdread-createcurrentA threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval w…
1.3.6.1.4.1.2011.1.3.4.4.1.1.9ColumnprialarmFallingThresholdread-createcurrentA threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was …
1.3.6.1.4.1.2011.1.3.4.4.1.1.10ColumnprialarmRisingEventIndexread-createcurrentThe index of the eventEntry that is used when a rising threshold is crossed. The eventEntry identified by a particular value of this index is the same as ident…
1.3.6.1.4.1.2011.1.3.4.4.1.1.11ColumnprialarmFallingEventIndexread-createcurrentThe index of the eventEntry that is used when a falling threshold is crossed. The eventEntry identified by a particular value of this index is the same as iden…
1.3.6.1.4.1.2011.1.3.4.4.1.1.12ColumnprialarmStatCycleread-createcurrentThe time alarm line exists. When the value of prialarmStatType is during(2),set prialarmStatCycle to decide how long the alarm line exists.
1.3.6.1.4.1.2011.1.3.4.4.1.1.13ColumnprialarmStatTyperead-createcurrentIt expresses alarm state type.To choose forever(1) , the alarm line will exist forever. To choose during(2) , the alarm line will be deleted after the time set…
1.3.6.1.4.1.2011.1.3.4.4.1.1.14ColumnprialarmOwnerread-createcurrentThe entity that configured this entry and is therefore using the resources assigned to it.
1.3.6.1.4.1.2011.1.3.4.4.1.1.15ColumnprialarmStatusread-createcurrentThe status of this alarm entry.
1.3.6.1.4.1.2011.1.3.4.4.2NodehwPerformanceConformance
1.3.6.1.4.1.2011.1.3.4.4.2.1NodehwPerformanceCompliances
1.3.6.1.4.1.2011.1.3.4.4.2.1.1CompliancehwPerformanceCompliancecurrentThe performance compliance.
1.3.6.1.4.1.2011.1.3.4.4.2.2NodehwPerformanceGroups
1.3.6.1.4.1.2011.1.3.4.4.2.2.1GrouphwPerformanceTrapGroupcurrentThe performance group.