MIB Viewer

HUAWEI-R2-MIB

66 objects
This MIB module defines MIB objects which provides R2 attribute management.
Imported Objects
HUAWEI-MIBhuaweiUtility
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMICounter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE private TimeTicks
SNMPv2-TCDisplayString RowStatus TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.6.108IdentityhwR2ProtocolThis MIB module defines MIB objects which provides R2 attribute management.
1.3.6.1.4.1.2011.6.108.1NodehwR2Objects
1.3.6.1.4.1.2011.6.108.1.1TablehwR2ProfileTablenot-accessiblecurrentR2 signaling profile table,this table is used to add,modify,del,query R2 profile templet. The index of this table is hwR2ProfileIndex
1.3.6.1.4.1.2011.6.108.1.1.1RowhwR2ProfileEntrynot-accessiblecurrentR2 signaling profile table,this table is used to add,modify,del,query R2 profile templet. The index of this entry is hwR2ProfileIndex
1.3.6.1.4.1.2011.6.108.1.1.1.1ColumnhwR2ProfileIndexnot-accessiblecurrentR2 signaling profile index
1.3.6.1.4.1.2011.6.108.1.1.1.2ColumnhwSignalNameread-writecurrentR2 signaling profile name
1.3.6.1.4.1.2011.6.108.1.1.1.3ColumnhwSignalTyperead-writecurrentR2 signaling type
1.3.6.1.4.1.2011.6.108.1.1.1.4ColumnhwR2SignalProfileRowStatusread-writecurrentRow status of R2 signaling profile
1.3.6.1.4.1.2011.6.108.1.2TablehwRegisterSignalAttributeTablenot-accessiblecurrentR2 register signaling attribute table,this table is used to set and query r2 profile register attribute The index of this table is hwRegisterSignalIndex
1.3.6.1.4.1.2011.6.108.1.2.1RowhwRegisterSignalAttributeEntrynot-accessiblecurrentR2 register signaling attribute table,this table is used to set and query r2 profile register attribute The index of this entry is hwRegisterSignalIndex
1.3.6.1.4.1.2011.6.108.1.2.1.1ColumnhwRegisterSignalIndexnot-accessiblecurrentR2 signaling profile index
1.3.6.1.4.1.2011.6.108.1.2.1.2ColumnhwRegisterOutgoingSignalTyperead-writecurrentSignaling type of outgoing office register Options: 1. mfc(1)-the register outgoing signal type is mfc 2. pulse(2) -the register outgoing signal type is pulse …
1.3.6.1.4.1.2011.6.108.1.2.1.3ColumnhwSignalSendVoltageread-writecurrentRegister signal transmit level(dbm) 1:-25dBm 2:-24dBm 3:-23dBm 4:-22dBm 5:-21dBm 6:-20dBm 7:-19dBm 8:-18dBm 9:-17dBm 10:-16dBm 11:-15dBm 12:-14dBm 13:-13dBm 14…
1.3.6.1.4.1.2011.6.108.1.2.1.4ColumnhwBackPulseTimeread-writecurrentBackword pulse duration(Multiple of 10; unit: ms)
1.3.6.1.4.1.2011.6.108.1.2.1.5ColumnhwDTMFSendTimeread-writecurrentDTMF signal transmit duration (ms)
1.3.6.1.4.1.2011.6.108.1.2.1.6ColumnhwDTMFSendIntervalread-writecurrentDTMF signal transmit interval (ms)
1.3.6.1.4.1.2011.6.108.1.2.1.7ColumnhwNoCallerPermitread-writeobsoleteCan the call be established without a calling party Options: 1. yes(1)- permit send caller number 2. no(2) - not permit send caller number
1.3.6.1.4.1.2011.6.108.1.2.1.8ColumnhwNumberMaxIntervalread-writecurrentMax. dialing interval (s)
1.3.6.1.4.1.2011.6.108.1.2.1.9ColumnhwSignalKeepMaxTimeread-writeobsoleteMax. signal duration (s)
1.3.6.1.4.1.2011.6.108.1.2.1.10ColumnhwReceiveNumberMaxIntervalread-writeobsoleteMax. interval of receiving calling(callee) signals (s)
1.3.6.1.4.1.2011.6.108.1.2.1.11ColumnhwSignalStopPermitTimeread-writeobsoleteMax. duration of signal interruption
1.3.6.1.4.1.2011.6.108.1.2.1.12ColumnhwWaitCallerCategoryTimeread-writecurrentWait time for receiving calling party type (s)
1.3.6.1.4.1.2011.6.108.1.2.1.13ColumnhwWaitBsignalTimeread-writecurrentWait time for receiving group B signal (s)
1.3.6.1.4.1.2011.6.108.1.2.1.14ColumnhwNumberSendModeread-writecurrentSignal transmit mode Options: 1. immediate(1)- number send immediately 2. delay(2) - number send delay
1.3.6.1.4.1.2011.6.108.1.2.1.15ColumnhwCallingNumberMaxLengthread-writecurrentMax. length of calling number
1.3.6.1.4.1.2011.6.108.1.2.1.16ColumnhwCompellingSequenceKeepaliveTimeread-writecurrentCompelling sequence keepalive time for register signaling (ms)
1.3.6.1.4.1.2011.6.108.1.2.1.17ColumnhwSendPulseSignalread-writecurrentWhether to send sending-finished signals Options: 1. yes(1)- send pulse signal 2. no(2) - do not send pulse signal
1.3.6.1.4.1.2011.6.108.1.2.1.18ColumnhwRegisterIncomingSignalTyperead-writecurrentSignaling type of incoming office register Options: 1. mfc(1)-the register incoming signal type is mfc 2. pulse(2) -the register incoming signal type is pulse …
1.3.6.1.4.1.2011.6.108.1.3TablehwLineSignalAttributeTablenot-accessiblecurrentR2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute. The index of this table is hwLineSignalIndex
1.3.6.1.4.1.2011.6.108.1.3.1RowhwLineSignalAttributeEntrynot-accessiblecurrentR2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute. The index of this entry is hwLineSignalIndex
1.3.6.1.4.1.2011.6.108.1.3.1.1ColumnhwLineSignalIndexnot-accessiblecurrentR2 profile index
1.3.6.1.4.1.2011.6.108.1.3.1.2ColumnhwLineSignalTyperead-writeobsoleteLine signaling type Options: 1. l1b(1)-line signal type is l1b 2. l2b(2) -line signal type is l2b 3. l3b(3) -line signal type is l3b 4. pulse(4) -line signal t…
1.3.6.1.4.1.2011.6.108.1.3.1.3ColumnhwWaitSeizeAckTimeread-writecurrentWait time for receiving occupation verification signal (ms)
1.3.6.1.4.1.2011.6.108.1.3.1.4ColumnhwWaitAnswerTimeread-writecurrentWait time for receiving answer signal (s)
1.3.6.1.4.1.2011.6.108.1.3.1.5ColumnhwWaitClearForwardTimeread-writecurrentWait time for receiving forward release signal (ms)
1.3.6.1.4.1.2011.6.108.1.3.1.6ColumnhwWaitProtectTimeread-writecurrentWait time for receiving release protection signal (ms)
1.3.6.1.4.1.2011.6.108.1.4TablehwAddressSendListTablenot-accessiblecurrentAttribute table for sent R2 address,this table is used to set and query register address send attribute. The index of this table is hwAddresssendInformationInd…
1.3.6.1.4.1.2011.6.108.1.4.1RowhwAddressSendListEntrynot-accessiblecurrentAttribute table for sent R2 address,this table is used to set and query register address send attribute. The index of this entry is hwAddresssendInformationInd…
1.3.6.1.4.1.2011.6.108.1.4.1.1ColumnhwAddresssendInformationIndexnot-accessiblecurrentR2 profile index
1.3.6.1.4.1.2011.6.108.1.4.1.2ColumnhwAddressSendInformationDIread-onlyobsoleteWhether to send called numbers Options: 1. yes(1)-register signal address send callee number
1.3.6.1.4.1.2011.6.108.1.4.1.3ColumnhwAddressSendInformationSIread-writecurrentWhether to send calling numbers Options: 1. yes(1)-register signal address send caller number 2. no(2)-register signal address does not send caller number
1.3.6.1.4.1.2011.6.108.1.4.1.4ColumnhwAddressSendInformationSCread-onlyobsoleteWhether to send calling party types Options: 1. yes(1)-register signal address send caller type
1.3.6.1.4.1.2011.6.108.1.4.1.5ColumnhwAddressSendInformationESread-writecurrentWhether to send echo cancelation info Options: 1. yes(1)-register signal address send echo suppression 2. no(2)-register signal address does not send echo supp…
1.3.6.1.4.1.2011.6.108.1.4.1.6ColumnhwAddressSendInformationCCread-writecurrentWhether to send country code Options: 1. yes(1)-register signal address send country code 2. no(2)-register signal address does not send country code
1.3.6.1.4.1.2011.6.108.1.4.1.7ColumnhwAddressSendInformationDISCread-writecurrentWhether to send separating signaling Options: 1. yes(1)-register signal address send discrimination flag 2. no(2)-register signal address does not send discrim…
1.3.6.1.4.1.2011.6.108.1.4.1.8ColumnhwAddressSendInformationNACread-writecurrentWhether to send circuit basic info Options: 1. yes(1)-register signal address send circuit character 2. no(2)-register signal address does not send circuit cha…
1.3.6.1.4.1.2011.6.108.1.4.1.9ColumnhwAddressSendInformationSPread-onlyobsoleteWhether to send the calling priority Options: 1. yes(1)-register signal address send caller priority 2. no(2)-register signal address does not send caller prio…
1.3.6.1.4.1.2011.6.108.1.5TablehwAddressReceiveListTablenot-accessiblecurrentAttribute table for received R2 address,this table is used to set and query register signal address receive attribute The index of this table is hwAddressRecei…
1.3.6.1.4.1.2011.6.108.1.5.1RowhwAddressReceiveListEntrynot-accessiblecurrentAttribute table for received R2 address,this table is used to set and query register signal address receive attribute The index of this entry is hwAddressRecei…
1.3.6.1.4.1.2011.6.108.1.5.1.1ColumnhwAddressReceiveInformationIndexnot-accessiblecurrentR2 profile index
1.3.6.1.4.1.2011.6.108.1.5.1.2ColumnhwAddressReceiveInformationDIread-onlyobsoleteWhether to receive called numbers Options: 1. yes(1)-register signal address receive callee number
1.3.6.1.4.1.2011.6.108.1.5.1.3ColumnhwAddressReceiveInformationSIread-writecurrentWhether to receive calling numbers Options: 1. yes(1)-register signal address receive calling number 2. no(2)-register signal address does not receive calling …
1.3.6.1.4.1.2011.6.108.1.5.1.4ColumnhwAddressReceiveInformationSCread-writecurrentWhether to receive calling party types Options: 1. yes(1)-register signal address receive calling user type 2. no(2)-register signal address does not receive c…
1.3.6.1.4.1.2011.6.108.1.5.1.5ColumnhwAddressReceiveInformationESread-writecurrentWhether to receive echo cancelation info Options: 1. yes(1)-register signal address receive echo suppression 2. no(2)-register signal address does not receive …
1.3.6.1.4.1.2011.6.108.1.5.1.6ColumnhwAddressReceiveInformationCCread-writecurrentWhether to receive country code Options: 1. yes(1)-register signal address receive country code 2. no(2)-register signal address does not receive country code
1.3.6.1.4.1.2011.6.108.1.5.1.7ColumnhwAddressReceiveInformationDISCread-writecurrentWhether to receive separating signaling Options: 1. yes(1)-register signal address receive distinctive indication 2. no(2)-register signal address does not rec…
1.3.6.1.4.1.2011.6.108.1.5.1.8ColumnhwAddressReceiveInformationNACread-writecurrentWhether to receive circuit basic info Options: 1. yes(1)-register signal address receive circuit character 2. no(2)-register signal address does not receive ci…
1.3.6.1.4.1.2011.6.108.1.5.1.9ColumnhwAddressReceiveInformationSPread-onlyobsoleteWhether to receive calling priority Options: 1. yes(1)-register signal address receive caller priority 2. no(2)-register signal address does not receive caller…
1.3.6.1.4.1.2011.6.108.1.5.1.10ColumnhwRequestCallerLineNoPositionread-writecurrentCalled number digits before requesting calling number (The calling number must be requested after the calling party type.)
1.3.6.1.4.1.2011.6.108.1.5.1.11ColumnhwRequestCallerLineTypePositionread-writecurrentCalled number digits before requesting calling party type (The calling party type must be requested before the calling number.)
1.3.6.1.4.1.2011.6.108.1.6NodehwR2SignalTypeVersionTable
1.3.6.1.4.1.2011.6.108.1.6.1ScalarhwSignalTypeVersionread-onlycurrentVersion of R2 signaling type file
1.3.6.1.4.1.2011.6.108.1.7TablehwR2SignalTypeTablenot-accessiblecurrentR2 signaling type table,this table is used to query R2 signal type information The index of this table is hwSignalTypeIndex
1.3.6.1.4.1.2011.6.108.1.7.1RowhwR2SignalTypeEntrynot-accessiblecurrentR2 signaling type table,this table is used to query R2 signal type information The index of this entry is hwSignalTypeIndex
1.3.6.1.4.1.2011.6.108.1.7.1.1ColumnhwSignalTypeIndexnot-accessiblecurrentR2 signaling type index
1.3.6.1.4.1.2011.6.108.1.7.1.2ColumnhwSignalTypeNameread-writecurrentR2 signaling type name The names of the preconfigured multiple countries adaption profiles with IDs ranging from 0 to 9 cannot be modified