HUAWEI-R2-MIB
66 objects
This MIB module defines MIB objects which provides R2 attribute management.
Imported Objects
| HUAWEI-MIB | huaweiUtility |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE private TimeTicks |
| SNMPv2-TC | DisplayString RowStatus TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.6.108 | IdentityhwR2Protocol | This MIB module defines MIB objects which provides R2 attribute management. | ||
| 1.3.6.1.4.1.2011.6.108.1 | NodehwR2Objects | |||
| 1.3.6.1.4.1.2011.6.108.1.1 | TablehwR2ProfileTable | not-accessible | current | R2 signaling profile table,this table is used to add,modify,del,query R2 profile templet. The index of this table is hwR2ProfileIndex |
| 1.3.6.1.4.1.2011.6.108.1.1.1 | RowhwR2ProfileEntry | not-accessible | current | R2 signaling profile table,this table is used to add,modify,del,query R2 profile templet. The index of this entry is hwR2ProfileIndex |
| 1.3.6.1.4.1.2011.6.108.1.1.1.1 | ColumnhwR2ProfileIndex | not-accessible | current | R2 signaling profile index |
| 1.3.6.1.4.1.2011.6.108.1.1.1.2 | ColumnhwSignalName | read-write | current | R2 signaling profile name |
| 1.3.6.1.4.1.2011.6.108.1.1.1.3 | ColumnhwSignalType | read-write | current | R2 signaling type |
| 1.3.6.1.4.1.2011.6.108.1.1.1.4 | ColumnhwR2SignalProfileRowStatus | read-write | current | Row status of R2 signaling profile |
| 1.3.6.1.4.1.2011.6.108.1.2 | TablehwRegisterSignalAttributeTable | not-accessible | current | R2 register signaling attribute table,this table is used to set and query r2 profile register attribute The index of this table is hwRegisterSignalIndex |
| 1.3.6.1.4.1.2011.6.108.1.2.1 | RowhwRegisterSignalAttributeEntry | not-accessible | current | R2 register signaling attribute table,this table is used to set and query r2 profile register attribute The index of this entry is hwRegisterSignalIndex |
| 1.3.6.1.4.1.2011.6.108.1.2.1.1 | ColumnhwRegisterSignalIndex | not-accessible | current | R2 signaling profile index |
| 1.3.6.1.4.1.2011.6.108.1.2.1.2 | ColumnhwRegisterOutgoingSignalType | read-write | current | Signaling type of outgoing office register Options: 1. mfc(1)-the register outgoing signal type is mfc 2. pulse(2) -the register outgoing signal type is pulse … |
| 1.3.6.1.4.1.2011.6.108.1.2.1.3 | ColumnhwSignalSendVoltage | read-write | current | Register signal transmit level(dbm) 1:-25dBm 2:-24dBm 3:-23dBm 4:-22dBm 5:-21dBm 6:-20dBm 7:-19dBm 8:-18dBm 9:-17dBm 10:-16dBm 11:-15dBm 12:-14dBm 13:-13dBm 14… |
| 1.3.6.1.4.1.2011.6.108.1.2.1.4 | ColumnhwBackPulseTime | read-write | current | Backword pulse duration(Multiple of 10; unit: ms) |
| 1.3.6.1.4.1.2011.6.108.1.2.1.5 | ColumnhwDTMFSendTime | read-write | current | DTMF signal transmit duration (ms) |
| 1.3.6.1.4.1.2011.6.108.1.2.1.6 | ColumnhwDTMFSendInterval | read-write | current | DTMF signal transmit interval (ms) |
| 1.3.6.1.4.1.2011.6.108.1.2.1.7 | ColumnhwNoCallerPermit | read-write | obsolete | Can the call be established without a calling party Options: 1. yes(1)- permit send caller number 2. no(2) - not permit send caller number |
| 1.3.6.1.4.1.2011.6.108.1.2.1.8 | ColumnhwNumberMaxInterval | read-write | current | Max. dialing interval (s) |
| 1.3.6.1.4.1.2011.6.108.1.2.1.9 | ColumnhwSignalKeepMaxTime | read-write | obsolete | Max. signal duration (s) |
| 1.3.6.1.4.1.2011.6.108.1.2.1.10 | ColumnhwReceiveNumberMaxInterval | read-write | obsolete | Max. interval of receiving calling(callee) signals (s) |
| 1.3.6.1.4.1.2011.6.108.1.2.1.11 | ColumnhwSignalStopPermitTime | read-write | obsolete | Max. duration of signal interruption |
| 1.3.6.1.4.1.2011.6.108.1.2.1.12 | ColumnhwWaitCallerCategoryTime | read-write | current | Wait time for receiving calling party type (s) |
| 1.3.6.1.4.1.2011.6.108.1.2.1.13 | ColumnhwWaitBsignalTime | read-write | current | Wait time for receiving group B signal (s) |
| 1.3.6.1.4.1.2011.6.108.1.2.1.14 | ColumnhwNumberSendMode | read-write | current | Signal transmit mode Options: 1. immediate(1)- number send immediately 2. delay(2) - number send delay |
| 1.3.6.1.4.1.2011.6.108.1.2.1.15 | ColumnhwCallingNumberMaxLength | read-write | current | Max. length of calling number |
| 1.3.6.1.4.1.2011.6.108.1.2.1.16 | ColumnhwCompellingSequenceKeepaliveTime | read-write | current | Compelling sequence keepalive time for register signaling (ms) |
| 1.3.6.1.4.1.2011.6.108.1.2.1.17 | ColumnhwSendPulseSignal | read-write | current | Whether to send sending-finished signals Options: 1. yes(1)- send pulse signal 2. no(2) - do not send pulse signal |
| 1.3.6.1.4.1.2011.6.108.1.2.1.18 | ColumnhwRegisterIncomingSignalType | read-write | current | Signaling type of incoming office register Options: 1. mfc(1)-the register incoming signal type is mfc 2. pulse(2) -the register incoming signal type is pulse … |
| 1.3.6.1.4.1.2011.6.108.1.3 | TablehwLineSignalAttributeTable | not-accessible | current | R2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute. The index of this table is hwLineSignalIndex |
| 1.3.6.1.4.1.2011.6.108.1.3.1 | RowhwLineSignalAttributeEntry | not-accessible | current | R2 line signaling attribute table,this table is used to set and query r2 profile line signal attribute. The index of this entry is hwLineSignalIndex |
| 1.3.6.1.4.1.2011.6.108.1.3.1.1 | ColumnhwLineSignalIndex | not-accessible | current | R2 profile index |
| 1.3.6.1.4.1.2011.6.108.1.3.1.2 | ColumnhwLineSignalType | read-write | obsolete | Line signaling type Options: 1. l1b(1)-line signal type is l1b 2. l2b(2) -line signal type is l2b 3. l3b(3) -line signal type is l3b 4. pulse(4) -line signal t… |
| 1.3.6.1.4.1.2011.6.108.1.3.1.3 | ColumnhwWaitSeizeAckTime | read-write | current | Wait time for receiving occupation verification signal (ms) |
| 1.3.6.1.4.1.2011.6.108.1.3.1.4 | ColumnhwWaitAnswerTime | read-write | current | Wait time for receiving answer signal (s) |
| 1.3.6.1.4.1.2011.6.108.1.3.1.5 | ColumnhwWaitClearForwardTime | read-write | current | Wait time for receiving forward release signal (ms) |
| 1.3.6.1.4.1.2011.6.108.1.3.1.6 | ColumnhwWaitProtectTime | read-write | current | Wait time for receiving release protection signal (ms) |
| 1.3.6.1.4.1.2011.6.108.1.4 | TablehwAddressSendListTable | not-accessible | current | Attribute table for sent R2 address,this table is used to set and query register address send attribute. The index of this table is hwAddresssendInformationInd… |
| 1.3.6.1.4.1.2011.6.108.1.4.1 | RowhwAddressSendListEntry | not-accessible | current | Attribute table for sent R2 address,this table is used to set and query register address send attribute. The index of this entry is hwAddresssendInformationInd… |
| 1.3.6.1.4.1.2011.6.108.1.4.1.1 | ColumnhwAddresssendInformationIndex | not-accessible | current | R2 profile index |
| 1.3.6.1.4.1.2011.6.108.1.4.1.2 | ColumnhwAddressSendInformationDI | read-only | obsolete | Whether to send called numbers Options: 1. yes(1)-register signal address send callee number |
| 1.3.6.1.4.1.2011.6.108.1.4.1.3 | ColumnhwAddressSendInformationSI | read-write | current | Whether to send calling numbers Options: 1. yes(1)-register signal address send caller number 2. no(2)-register signal address does not send caller number |
| 1.3.6.1.4.1.2011.6.108.1.4.1.4 | ColumnhwAddressSendInformationSC | read-only | obsolete | Whether to send calling party types Options: 1. yes(1)-register signal address send caller type |
| 1.3.6.1.4.1.2011.6.108.1.4.1.5 | ColumnhwAddressSendInformationES | read-write | current | Whether to send echo cancelation info Options: 1. yes(1)-register signal address send echo suppression 2. no(2)-register signal address does not send echo supp… |
| 1.3.6.1.4.1.2011.6.108.1.4.1.6 | ColumnhwAddressSendInformationCC | read-write | current | Whether to send country code Options: 1. yes(1)-register signal address send country code 2. no(2)-register signal address does not send country code |
| 1.3.6.1.4.1.2011.6.108.1.4.1.7 | ColumnhwAddressSendInformationDISC | read-write | current | Whether to send separating signaling Options: 1. yes(1)-register signal address send discrimination flag 2. no(2)-register signal address does not send discrim… |
| 1.3.6.1.4.1.2011.6.108.1.4.1.8 | ColumnhwAddressSendInformationNAC | read-write | current | Whether to send circuit basic info Options: 1. yes(1)-register signal address send circuit character 2. no(2)-register signal address does not send circuit cha… |
| 1.3.6.1.4.1.2011.6.108.1.4.1.9 | ColumnhwAddressSendInformationSP | read-only | obsolete | Whether to send the calling priority Options: 1. yes(1)-register signal address send caller priority 2. no(2)-register signal address does not send caller prio… |
| 1.3.6.1.4.1.2011.6.108.1.5 | TablehwAddressReceiveListTable | not-accessible | current | Attribute table for received R2 address,this table is used to set and query register signal address receive attribute The index of this table is hwAddressRecei… |
| 1.3.6.1.4.1.2011.6.108.1.5.1 | RowhwAddressReceiveListEntry | not-accessible | current | Attribute table for received R2 address,this table is used to set and query register signal address receive attribute The index of this entry is hwAddressRecei… |
| 1.3.6.1.4.1.2011.6.108.1.5.1.1 | ColumnhwAddressReceiveInformationIndex | not-accessible | current | R2 profile index |
| 1.3.6.1.4.1.2011.6.108.1.5.1.2 | ColumnhwAddressReceiveInformationDI | read-only | obsolete | Whether to receive called numbers Options: 1. yes(1)-register signal address receive callee number |
| 1.3.6.1.4.1.2011.6.108.1.5.1.3 | ColumnhwAddressReceiveInformationSI | read-write | current | Whether to receive calling numbers Options: 1. yes(1)-register signal address receive calling number 2. no(2)-register signal address does not receive calling … |
| 1.3.6.1.4.1.2011.6.108.1.5.1.4 | ColumnhwAddressReceiveInformationSC | read-write | current | Whether to receive calling party types Options: 1. yes(1)-register signal address receive calling user type 2. no(2)-register signal address does not receive c… |
| 1.3.6.1.4.1.2011.6.108.1.5.1.5 | ColumnhwAddressReceiveInformationES | read-write | current | Whether to receive echo cancelation info Options: 1. yes(1)-register signal address receive echo suppression 2. no(2)-register signal address does not receive … |
| 1.3.6.1.4.1.2011.6.108.1.5.1.6 | ColumnhwAddressReceiveInformationCC | read-write | current | Whether to receive country code Options: 1. yes(1)-register signal address receive country code 2. no(2)-register signal address does not receive country code |
| 1.3.6.1.4.1.2011.6.108.1.5.1.7 | ColumnhwAddressReceiveInformationDISC | read-write | current | Whether to receive separating signaling Options: 1. yes(1)-register signal address receive distinctive indication 2. no(2)-register signal address does not rec… |
| 1.3.6.1.4.1.2011.6.108.1.5.1.8 | ColumnhwAddressReceiveInformationNAC | read-write | current | Whether to receive circuit basic info Options: 1. yes(1)-register signal address receive circuit character 2. no(2)-register signal address does not receive ci… |
| 1.3.6.1.4.1.2011.6.108.1.5.1.9 | ColumnhwAddressReceiveInformationSP | read-only | obsolete | Whether to receive calling priority Options: 1. yes(1)-register signal address receive caller priority 2. no(2)-register signal address does not receive caller… |
| 1.3.6.1.4.1.2011.6.108.1.5.1.10 | ColumnhwRequestCallerLineNoPosition | read-write | current | Called number digits before requesting calling number (The calling number must be requested after the calling party type.) |
| 1.3.6.1.4.1.2011.6.108.1.5.1.11 | ColumnhwRequestCallerLineTypePosition | read-write | current | Called number digits before requesting calling party type (The calling party type must be requested before the calling number.) |
| 1.3.6.1.4.1.2011.6.108.1.6 | NodehwR2SignalTypeVersionTable | |||
| 1.3.6.1.4.1.2011.6.108.1.6.1 | ScalarhwSignalTypeVersion | read-only | current | Version of R2 signaling type file |
| 1.3.6.1.4.1.2011.6.108.1.7 | TablehwR2SignalTypeTable | not-accessible | current | R2 signaling type table,this table is used to query R2 signal type information The index of this table is hwSignalTypeIndex |
| 1.3.6.1.4.1.2011.6.108.1.7.1 | RowhwR2SignalTypeEntry | not-accessible | current | R2 signaling type table,this table is used to query R2 signal type information The index of this entry is hwSignalTypeIndex |
| 1.3.6.1.4.1.2011.6.108.1.7.1.1 | ColumnhwSignalTypeIndex | not-accessible | current | R2 signaling type index |
| 1.3.6.1.4.1.2011.6.108.1.7.1.2 | ColumnhwSignalTypeName | read-write | current | R2 signaling type name The names of the preconfigured multiple countries adaption profiles with IDs ranging from 0 to 9 cannot be modified |