HUAWEI-SITE-MONITOR-MIB
462 objects
Site Monitor MIB defines MIB objects which provides load and backup management, patch management NMS interfaces. The current version is V1.01
Imported Objects
| HUAWEI-MIB | huaweiUtility |
| SNMPv2-CONF | NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.6.164 | IdentityhwSiteMonitorMIB | Site Monitor MIB defines MIB objects which provides load and backup management, patch management NMS interfaces. The current version is V1.01 | ||
| 1.3.6.1.4.1.2011.6.164.1 | NodehwSiteMonitorMIBObjects | |||
| 1.3.6.1.4.1.2011.6.164.1.1 | NodehwSiteInfo | |||
| 1.3.6.1.4.1.2011.6.164.1.1.1 | NodehwSiteSummary | |||
| 1.3.6.1.4.1.2011.6.164.1.1.1.1 | ScalarhwSiteId | read-only | current | Site ID, default value: 000,000. Naming rule of the site device ID (six digits): The first three digits indicate the device name and the last three digits indi… |
| 1.3.6.1.4.1.2011.6.164.1.1.1.2 | ScalarhwSiteName | read-write | current | Site name, which users can configure, is used to specify a site. Otherwise, the configured character can not be any other languages except English. |
| 1.3.6.1.4.1.2011.6.164.1.1.1.3 | ScalarhwSiteAdminAddr | read-write | current | Site administrant address, which users can assigned, is the unique ID of a site. It is used for device management by NMS, and value range is 0 to 65535. |
| 1.3.6.1.4.1.2011.6.164.1.1.1.4 | ScalarhwSiteDescription | read-write | current | Site description. It is of the character string type. It is used to describe the site information such as the site location, which users can configure. Otherwi… |
| 1.3.6.1.4.1.2011.6.164.1.1.1.5 | ScalarhwNetIdentifier | read-write | current | NE ID. It is of the character string type. It is the unique ID of the site (an independent network element (NE)) on the network. Otherwise, the configured char… |
| 1.3.6.1.4.1.2011.6.164.1.1.1.6 | ScalarhwSiteIp | read-only | current | Site IP address, default value is 192.168.0.10. Users need to configure the site IP address. |
| 1.3.6.1.4.1.2011.6.164.1.1.1.7 | ScalarhwSiteNetmask | read-only | current | Site netmask, default value is 255.255.0.0. Users need to configure the site netmask. |
| 1.3.6.1.4.1.2011.6.164.1.1.1.8 | ScalarhwSiteGateway | read-only | current | Site gateway, default value: 192.168.0.1. Users need to configure the site gateway. |
| 1.3.6.1.4.1.2011.6.164.1.1.1.9 | ScalarhwSiteDGWorkStatus | read-only | current | State of the diesel working state. It is an enumeration type: If the enumeration value is 1, it indicates that the diesel is in the idle state; If the enumerat… |
| 1.3.6.1.4.1.2011.6.164.1.1.2 | NodehwSiteAlarms | |||
| 1.3.6.1.4.1.2011.6.164.1.1.2.1 | ScalarhwDeviceTrapOrdinalNumber | read-write | current | Site device event trap serial number (SN) is the unique ID of the device event trap. It is used to resend and synchronize event traps. Its value range is 0 to … |
| 1.3.6.1.4.1.2011.6.164.1.1.2.2 | ScalarhwAlarmTrapOrdinalNumber | read-write | current | Site alarm serial number (SN) is the unique ID of the alarm Trap. It is used to resend and synchronize alarms. Its value range is 0 to 4294967296. When the val… |
| 1.3.6.1.4.1.2011.6.164.1.1.2.3 | ScalarhwAlarmQuantity | read-only | current | Alarm number in site alarm list which are support. It is used for alarm list management by NMS, and value range is 0 to 65535. |
| 1.3.6.1.4.1.2011.6.164.1.1.2.100 | TablehwSiteAlarmTable | not-accessible | current | Site alarms table. The table containing alarm information on the site management. Use this table to get site alarm name, alarm level, alarm signal description,… |
| 1.3.6.1.4.1.2011.6.164.1.1.2.100.1 | RowhwSiteAlarmEntry | not-accessible | current | Site alarms table entry. |
| 1.3.6.1.4.1.2011.6.164.1.1.2.100.1.1 | ColumnhwAlarmIndex | read-only | current | Site alarm table index. It is the unique ID of the site alarm. |
| 1.3.6.1.4.1.2011.6.164.1.1.2.100.1.2 | ColumnhwAlarmText | read-only | current | Alarm name. It is of the character string type, and used to specify the content of a specific alarm. |
| 1.3.6.1.4.1.2011.6.164.1.1.2.100.1.3 | ColumnhwAlarmLevel | read-write | current | Alarm level, which users can configure the alarm severity, is an enumeration type: If the enumeration value is 1, it indicates a critical alarm; If the enumera… |
| 1.3.6.1.4.1.2011.6.164.1.1.2.100.1.4 | ColumnhwAlarmSigDesc | read-write | current | Alarm signal description. It is used to add and describe alarm content. Users can define the description of the alarm. Otherwise, the configured character can … |
| 1.3.6.1.4.1.2011.6.164.1.1.2.100.1.100 | ColumnhwAlarmRowStatus | read-create | current | RowStatus of site alarms table. |
| 1.3.6.1.4.1.2011.6.164.1.2 | NodehwSiteMonitors | |||
| 1.3.6.1.4.1.2011.6.164.1.2.1 | NodehwMonitorsGroup | |||
| 1.3.6.1.4.1.2011.6.164.1.2.1.1 | ScalarhwMonsGroupId | read-only | current | Site monitor group ID, is the unique ID of the site monitors. |
| 1.3.6.1.4.1.2011.6.164.1.2.1.2 | ScalarhwMonsGroupName | read-write | current | Site monitor group name is of the character string type, used to specify the monitor group. Users can configure it. Otherwise, the configured character can not… |
| 1.3.6.1.4.1.2011.6.164.1.2.1.3 | ScalarhwMonsQuantity | read-only | current | Total site intelligent monitors. |
| 1.3.6.1.4.1.2011.6.164.1.2.2 | NodehwMonitor | |||
| 1.3.6.1.4.1.2011.6.164.1.2.2.1 | TablehwMonitorTable | not-accessible | current | Site monitors table. Use this table to get site monitor equipment ID, site monitor equipment name, equipment software version, equipment PCB version, manufactu… |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1 | RowhwMonitorEntry | not-accessible | current | Site monitors table entry. |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.1 | ColumnhwMonIndex | read-only | current | Table index of the site monitors (hwSiteMonsTab) is restricted by the quantity of the site monitors (hwMonsQuantity). Value range: 1 to 100 |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.2 | ColumnhwMonEquipId | read-only | current | Site monitor ID. Value range: 001,001 to 001,100, in which the first three digits indicate the device type and the last three digits indicate the device SN. |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.3 | ColumnhwMonEquipName | read-write | current | Monitor name. It is of the character string type, and users can set the name of the monitor. Otherwise, the configured character can not be any other languages… |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.4 | ColumnhwMonEquipDescription | read-write | current | Monitor description. It is of the character string type. Users can set the description of the monitor. Otherwise, the configured character can not be any other… |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.5 | ColumnhwMonEquipSoftwareVersion | read-only | current | Monitor software version. It is of the character string type. |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.6 | ColumnhwMonEquipPcbVersion | read-only | current | Monitor printed circuit board (PCB) hardware version. It is of the character string type. |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.7 | ColumnhwMonEquipManufacturer | read-only | current | Monitor manufacture. It is of the character string type, and is an inherent attribute of the device. |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.8 | ColumnhwMonEquipManuDate | read-only | current | Monitor production date. It is of the character string type, and is an inherent attribute of the device. |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.9 | ColumnhwMonEquipSerialNo | read-only | current | Production SN of the monitor. It is the electronic tag of the products. |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.10 | ColumnhwMonEquipOperTotalTime | read-only | current | Total monitor runtime. The monitor counts the data in real time. The value is an integer (.0), and unit is hour (h). It is used for performance measurement and… |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.11 | ColumnhwSetMonEquipCtrlState | read-write | current | Monitor control status. It is an enumeration type: If the enumeration value is 1, it indicates the background control; If the enumeration value is 2, it indica… |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.12 | ColumnhwCtrlMonEquipReset | read-write | current | Warm-reset control of the monitor. It is an enumeration type: If the network management system (NMS) notifies the SNMP agent that this node is set to 1, it ind… |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.99 | ColumnhwMonitorOperStatus | read-only | current | State of the site monitor module. It is an enumeration type: If the enumeration value is 1, it indicates that the site monitor module is in the normal state; I… |
| 1.3.6.1.4.1.2011.6.164.1.2.2.1.1.100 | ColumnhwMonRowStatus | read-create | current | RowStatus of site monitor. |
| 1.3.6.1.4.1.2011.6.164.1.3 | NodehwSiteRectifiers | |||
| 1.3.6.1.4.1.2011.6.164.1.3.1 | NodehwRectsGroup | |||
| 1.3.6.1.4.1.2011.6.164.1.3.1.1 | ScalarhwRectsGroupId | read-only | current | Device group ID of the rectifier module. It is the unique ID of the rectifier module group, and its default value: 002,000. The first digits indicate the devic… |
| 1.3.6.1.4.1.2011.6.164.1.3.1.2 | ScalarhwRectsGroupName | read-write | current | Name of the rectifier module group, character string type, is used to specify the rectifier module group. Users can configure it. Otherwise, the configured cha… |
| 1.3.6.1.4.1.2011.6.164.1.3.1.3 | ScalarhwRectsTotalCurrent | read-only | current | Total current of the rectifier module group on the site. It indicates the real-time statistics of the rectifier module group on the site. unit: A, and the valu… |
| 1.3.6.1.4.1.2011.6.164.1.3.1.4 | ScalarhwRectsTotalQuantity | read-only | current | Total quantity of the rectifier modules. Value range: 0 to 256. |
| 1.3.6.1.4.1.2011.6.164.1.3.1.5 | ScalarhwRectsRatedVoltage | read-only | current | Rated voltage of the rectifier module group. It is an inherent attribute. Value range: 42 to 58, Unit: V, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.3.1.6 | ScalarhwModifyRectsOutputVoltage | read-write | current | Voltage adjustment of the rectifier module, which users can configure it. Value range: 42 to 58, Unit: V, and the value is accurate to one decimal space (.1). … |
| 1.3.6.1.4.1.2011.6.164.1.3.1.7 | ScalarhwSetRectsRedundEnable | read-write | current | Sleep function of the rectifier module group on the site. It is an enumeration value: If the NMS notifies the SNMP agent that this node is set to 1, it means t… |
| 1.3.6.1.4.1.2011.6.164.1.3.1.8 | ScalarhwCtrlRectsAllOnOff | read-write | current | Power-on or power-off of the rectifier module group (all the rectifier modules) on the site. It is an enumeration value: If the NMS notifies the SNMP agent tha… |
| 1.3.6.1.4.1.2011.6.164.1.3.2 | NodehwRectifier | |||
| 1.3.6.1.4.1.2011.6.164.1.3.2.1 | TablehwRectConfigTable | not-accessible | current | Rectifier config information table. Use this table to get rectifiers equipment ID, software version, manufacturer, rated current, efficency, AC input type, and… |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1 | RowhwRectConfigEntry | not-accessible | current | Rectifier config table entry. |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.1 | ColumnhwRectConfigIndex | read-only | current | Index of the device configuration list for the rectifier modules, which value range: 1 to 256. Lines of the device list are restricted by the total quantity of… |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.2 | ColumnhwRectEquipId | read-only | current | Rectifier module ID. Value range: 002'001 to 002'255. The first digits indicate the device type and last three digits indicate the device SN. |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.3 | ColumnhwRectEquipName | read-write | current | Device name of the rectifier module, character string type, is used to specify the rectifier module. Users can configure it. Otherwise, the configured characte… |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.4 | ColumnhwRectType | read-only | current | Specific type of the rectifier module. It is an enumeration type: If the enumeration value is 1, it indicates a 5A rectifier module; If the enumeration value i… |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.5 | ColumnhwRectSoftwareVersion | read-only | current | Software version of the rectifier module. It indicates the software version ID of the module. |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.6 | ColumnhwRectManufacturer | read-only | current | Manufacture of the rectifier module. |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.7 | ColumnhwRectManuDate | read-only | current | Manufacture date of rectifiers is of string type. |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.8 | ColumnhwRectSerialNo | read-only | current | Rectifier module SN. It indicates the electronic tag of the product. |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.9 | ColumnhwRectRatedCurrent | read-only | current | Rated voltage of the rectifier module, is an inherent attribute. Value range: 0 to 100, Unit: A, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.10 | ColumnhwRectEfficency | read-only | current | Efficiency of the rectifier module, is an inherent attribute. Value range: 80 to 100, Unit: %, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.11 | ColumnhwRectInputAcType | read-only | current | Input AC type of the rectifier module. It is an enumeration value: If the value of the node is 1, it indicates single-phase AC input; If the value of the node … |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.12 | ColumnhwCtrlRectOnOff | read-write | current | Power-on or power-off of the rectifier module, is an enumeration value. Users can modify the enumeration value of this node, thus controlling of the power-on o… |
| 1.3.6.1.4.1.2011.6.164.1.3.2.1.1.100 | ColumnhwRectConfigRowStatus | read-create | current | RowStatus of rectifier config table. |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2 | TablehwRectOperTable | not-accessible | current | Rectifier runing information table. Use this table to get rectifiers output current, output voltage, totle runing time, and current run status. This table's in… |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1 | RowhwRectOperEntry | not-accessible | current | Rectifier runing table entry. |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.1 | ColumnhwRectOperIndex | read-only | current | Table index of the running rectifier modules, which value range: 1 to 256. Lines of the device list are restricted by the total quantity of the rectifier modul… |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.2 | ColumnhwRectOutputCurrent | read-only | current | Output current of the rectifier module. It is a real-time analog parameter. Value range: 0 to 200, Unit: A, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.3 | ColumnhwRectOutputVoltage | read-only | current | Output voltage of the rectifier module. It is a real-time analog parameter. Value range: 0 to 60, Unit: V, the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.4 | ColumnhwRectTotalOperTime | read-only | current | Total runtime of the rectifier module. Value unit: minute (m), and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.99 | ColumnhwRectOperStatus | read-only | current | State of the rectifier module. It is an enumeration type: If the enumeration value is 1, it indicates that the rectifier module is in the normal state; If the … |
| 1.3.6.1.4.1.2011.6.164.1.3.2.2.1.100 | ColumnhwRectOperRowStatus | read-create | current | RowStatus of rectifier runing table. |
| 1.3.6.1.4.1.2011.6.164.1.4 | NodehwSiteBatterys | |||
| 1.3.6.1.4.1.2011.6.164.1.4.1 | NodehwBattsConfig | |||
| 1.3.6.1.4.1.2011.6.164.1.4.1.1 | ScalarhwBattsGroupId | read-only | current | Battery group ID. It is the unique ID of the battery group device. The first digits indicate the device type and the last three digits indicate the device SN. … |
| 1.3.6.1.4.1.2011.6.164.1.4.1.2 | ScalarhwBattsGroupName | read-write | current | Device name of the battery group. It is of the character string type, which can be configured by users. Otherwise, the configured character can not be any othe… |
| 1.3.6.1.4.1.2011.6.164.1.4.1.3 | ScalarhwBattsTotalQuantity | read-write | current | Total quantity of battery strings, which value range: 0 to 100. |
| 1.3.6.1.4.1.2011.6.164.1.4.1.4 | ScalarhwSetBattsHighTempAction | read-write | current | Battery high-temperature protection mode. It is an enumeration value, and can be configured. If the enumeration value is 1, it indicates the power-off protecti… |
| 1.3.6.1.4.1.2011.6.164.1.4.1.5 | ScalarhwSetBattsHighTempVoltLimit | read-write | current | Battery protection voltage under high temperature. It works with the low-voltage power-off protection in battery high-temperature protection mode, which can be… |
| 1.3.6.1.4.1.2011.6.164.1.4.1.6 | ScalarhwSetBattsHTDLimit | read-write | current | Upper threshold of the battery high temperature disconnection(HTD), can be configured by users. Value range: 0 to 100, Unit: centigrade (°„C), and the value… |
| 1.3.6.1.4.1.2011.6.164.1.4.1.7 | ScalarhwSetBattsHTDEnable | read-write | current | Battery high temperature disconnection enable. It is an enumeration type: If the enumeration value is 1, enable the operation of the battery disconnection in h… |
| 1.3.6.1.4.1.2011.6.164.1.4.1.8 | ScalarhwSetBattsFloatVoltage | read-write | current | Float charge voltage of the batteries, can be configured by users. Value range: 42 to 58, unit: V, and the value is accurate to one decimal place (.1) |
| 1.3.6.1.4.1.2011.6.164.1.4.1.9 | ScalarhwSetBattsBoostVoltage | read-write | current | Boostcharge voltage of the batteries, can be configured by users. Value range: 42 to 58, unit: V, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.4.1.10 | ScalarhwSetBattsCurrLimitCoefficient | read-write | current | Current-limiting point coefficient of the batteries, can be configured by users. Value range: 0.05 to 0.25, unit: C10, and the value is accurate to two decimal… |
| 1.3.6.1.4.1.2011.6.164.1.4.1.11 | ScalarhwSetBattsCompFactor | read-write | current | Temperature compensated coefficient of the batteries, can be configured by user. Value range: 0 to 500, unit: mv per centigrade, and the value is an integer (.… |
| 1.3.6.1.4.1.2011.6.164.1.4.1.12 | ScalarhwCtrlBattsBoostFloat | read-write | current | Control batteries charge mode between boost and float. It is an enumeration value. Users actively control the conversion. If the NMS notifies the SNMP agent th… |
| 1.3.6.1.4.1.2011.6.164.1.4.2 | NodehwBattsOperate | |||
| 1.3.6.1.4.1.2011.6.164.1.4.2.1 | ScalarhwBattsTotalCurrent | read-only | current | Total current of the battery group. It indicates the real-time statistics of the battery group on the site. Value range: -1000 to +1000, unit: A, and the value… |
| 1.3.6.1.4.1.2011.6.164.1.4.2.2 | ScalarhwBattsPreDischargeTime | read-only | current | Battery group backup time. It indicates the real-time statistics of the battery group. Value range: 0 to 65536, Unit: minute (m), and the value is an integer (… |
| 1.3.6.1.4.1.2011.6.164.1.4.2.3 | ScalarhwBattsChargeStatus | read-only | current | Battery charging state, indicates the charging and discharging information about the battery group. It is an enumeration type. If the enumeration value is 1, i… |
| 1.3.6.1.4.1.2011.6.164.1.4.2.4 | ScalarhwBattsCurrLimitStatus | read-only | current | Battery group current-limiting state, indicates the state information about the battery group. It is an enumeration value. If the enumeration value is 1, it in… |
| 1.3.6.1.4.1.2011.6.164.1.4.3 | NodehwBattsTest | |||
| 1.3.6.1.4.1.2011.6.164.1.4.3.1 | ScalarhwBattsTestRecordCount | read-only | current | Battery test records number. |
| 1.3.6.1.4.1.2011.6.164.1.4.3.2 | ScalarhwSetBattsManuStdTestTime | read-write | current | Battery standard test time, It can be configured by users, and its value is an integer (.0). Here, if battery manual test is standard mode, value range defines… |
| 1.3.6.1.4.1.2011.6.164.1.4.3.3 | ScalarhwSetBattsManuStdTestEndVolt | read-write | current | Voltage when the battery test is ended, can be configured by users. Unit: V/cell, and the value is accurate to two decimal place (.2). Here, if battery manual … |
| 1.3.6.1.4.1.2011.6.164.1.4.3.4 | ScalarhwSetBattsManuStdTestCellNum | read-write | current | Battery cell number in each Group, which is used in the battery standard manual test, can be configured by users. Unit: psc or cell, value range defines betwee… |
| 1.3.6.1.4.1.2011.6.164.1.4.3.5 | ScalarhwSetBattsManuShortTestTime | read-write | current | Battery short test time, It can be configured by users, and its value is an integer (.0). If battery manual test is simple mode, value range defines between 1 … |
| 1.3.6.1.4.1.2011.6.164.1.4.3.6 | ScalarhwSetBattsManuShortTestEndVolt | read-write | current | Voltage when the battery short test is ended, can be configured by users. Unit: V, and the value is accurate to one decimal place (.1). Here, if battery manual… |
| 1.3.6.1.4.1.2011.6.164.1.4.3.7 | ScalarhwCtrlBattsTestStartStop | read-write | current | Battery manualtest start and stop. It is an enumeration value. If the NMS notifies the SNMP agent that the node is set to 1, it means to start a standard manua… |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100 | TablehwBattsTestResultTable | not-accessible | current | Battery test result record table. Use this table to get battery test inital time, test result, battery efficiency, battery discharge time, terminated voltage, … |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1 | RowhwBattsTestResultEntry | not-accessible | current | Battery test result table entry. |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.1 | ColumnhwBattsTestResultIndex | read-only | current | Table index of the battery test results. Currently up to 10 times of the battery test results are saved by default. |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.2 | ColumnhwBattsTestType | read-only | current | Record test type of the battery test. It is an enumeration value: If the NMS notifies the SNMP agent that this node is set to 1, it indicates a manual test; If… |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.3 | ColumnhwBattsTestStartTime | read-only | current | Test start time of the record in the battery test. It is of the character string type. |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.4 | ColumnhwBattsTestResult | read-only | current | Battery test result. It is an enumeration value. If the enumeration value of the node is 1, it indicates that the battery test has no result: If the enumeratio… |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.5 | ColumnhwBattsEfficiency | read-only | current | Battery efficiency test. Value range: 0 to 100, Unit: %, and the value is an integer (.0). If the value is -1, it indicates that the test value is inefficient. |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.6 | ColumnhwBattsDischargeTime | read-only | current | Discharge time of the battery test records. Value range: 0 to 100, unit: hour (h), and the value is accurate to two decimal places (.2). |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.7 | ColumnhwBattsDischargeEndVoltage | read-only | current | Discharge termination voltage of the battery test. Value range: 0 to 60, unit: V, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.8 | ColumnhwBattsDischargeAvCurrent | read-only | current | Average discharge current of the battery test. Value range: -10000 to 10000, unit: A, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.9 | ColumnhwBattsDischargeAhValue | read-only | current | Discharge ampere per hour the battery test. Value range: 0 to 5000, Unit: Ah, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.10 | ColumnhwBattsTestTemprature | read-only | current | Battery temperature of the battery test termination. Value range: -50 to +100, Unit: centigrade (°„C), and the value is an integer (.0). If the value is -10… |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.11 | ColumnhwBattsTestEndCourse | read-only | current | Termination factors of the battery test. It is an enumeration value. If the enumeration value is 1, it indicates that the voltage value of the battery test rea… |
| 1.3.6.1.4.1.2011.6.164.1.4.3.100.1.100 | ColumnhwBattsTestResultRowStatus | read-create | current | RowStatus of battery test table. |
| 1.3.6.1.4.1.2011.6.164.1.4.4 | NodehwBattString | |||
| 1.3.6.1.4.1.2011.6.164.1.4.4.1 | TablehwBattStringConfigTable | not-accessible | current | Battery string config table. Use this table to get battery string equipment ID and equipment name, to set battery standard capacity and battery install time as… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1 | RowhwBattStringConfigEntry | not-accessible | current | Battery string config table entry. |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.1 | ColumnhwBattStringConfigIndex | read-only | current | Device table index of the battery string, which value range: 1 to 100. |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.2 | ColumnhwBattStringEquipId | read-only | current | Batteries device ID, can be configured by users. Value range: 003,001 to 003,100, in which the first three digits specify the device type and the last three sp… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.3 | ColumnhwBattStringEquipName | read-write | current | Batteries device name, of the character string type, is used to specify the batteries. Users can configure it. Otherwise, the configured character can not be a… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.4 | ColumnhwSetBattsTempUpperLimit | read-write | current | Upper threshold of the battery temperature alarm, can be configured by users. Value range: -50 to 100, Unit: centigrade (°„C), and the value is an integer (… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.5 | ColumnhwSetBattsTempLowerLimit | read-write | current | Lower threshold of the battery temperature alarm, can be configured by users. Value range: -50 to 100, Unit: centigrade (°„C), and the value is an integer (… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.6 | ColumnhwSetBattsTempMeasureUpperLimit | read-write | current | Upper threshold of the battery temperature measurement, can be configured by users. Value range: 0 to 100, Unit: centigrade (°„C), and the value is an integ… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.7 | ColumnhwSetBattsTempMeasureLowerLimit | read-write | current | Lower threshold of the battery temperature measurement, can be configured by users. Value range: -50 to 0, Unit: centigrade (°„C), and the value is an integ… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.8 | ColumnhwSetBattStdCapacity | read-write | current | Set battery standard capacity, is an inherent attribute of the device. Value range: 0 to 10000, unit: Ah, the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.9 | ColumnhwSetBattInstallTime | read-write | current | Set battery install time, of the character string type, can be configured by users. Otherwise, the configured character can not be any other languages except E… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.1.1.100 | ColumnhwBattStringConfigRowStatus | read-create | current | RowStatus of battery string config table. |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2 | TablehwBattStringOperTable | not-accessible | current | Battery string runing table. Use this table to get battery string current, persent of remain capacity, battery remain capacity, battery actual capacity, as wel… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2.1 | RowhwBattStringOperEntry | not-accessible | current | Battery string runing table entry. |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2.1.1 | ColumnhwBattStringOperIndex | read-only | current | Device table index of the battery string, which value range: 1 to 100. |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2.1.2 | ColumnhwBattStringCurrent | read-only | current | Batteries current. It is an analog parameter collected by the battery string in real time. Value range: -1000 to +1000, unit: A, and the value is accurate to o… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2.1.3 | ColumnhwBattStringRemainCapacityPercent | read-only | current | Remaining capacity percentage of the battery string. Value range: 0 to 100, unit: %, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2.1.4 | ColumnhwBattStringRemainCapacity | read-only | current | Remaining capacity of the battery string. It is an analog parameter collected by the battery string in real time. Value range: 0 to 5000, unit: Ah, and the val… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2.1.5 | ColumnhwBattStringActualCapacity | read-only | current | Batteries actual capacity. It is an analog parameter collected by the battery string in real time.Value range: 0 to 5000, unit: Ah, the value is an integer (.0… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2.1.6 | ColumnhwBattStringTemprature | read-only | current | Battery temperature. It is a battery parameter collected in real time. Value range: -50 to +100, unit: centigrade (°„C), and the value is an integer (.1). I… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2.1.99 | ColumnhwBattStringOperStatus | read-only | current | State of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal s… |
| 1.3.6.1.4.1.2011.6.164.1.4.4.2.1.100 | ColumnhwBattStringOperRowStatus | read-create | current | RowStatus of battery string runing table. |
| 1.3.6.1.4.1.2011.6.164.1.5 | NodehwSiteAcDistributions | |||
| 1.3.6.1.4.1.2011.6.164.1.5.1 | NodehwAcDistributionsGroup | |||
| 1.3.6.1.4.1.2011.6.164.1.5.1.1 | ScalarhwAcsGroupId | read-only | current | AC group ID, is the unique ID of the AC group. The first three digits indicate the device type and the last three indicate the device SN. If the last three dig… |
| 1.3.6.1.4.1.2011.6.164.1.5.1.2 | ScalarhwAcsGroupName | read-write | current | Device name of the AC group. It is of the character string type, and can be configured by users. Otherwise, the configured character can not be any other langu… |
| 1.3.6.1.4.1.2011.6.164.1.5.1.3 | ScalarhwAcsTotalCurrent | read-only | current | Total current of the AC group. It indicates the real-time statistics of the AC group. Value range: 0 to 1000, unit: A, and the value is accurate to one decimal… |
| 1.3.6.1.4.1.2011.6.164.1.5.1.4 | ScalarhwAcsTotalQuantity | read-only | current | Total quantity of the site ACUs. Value range: 0 to 100. |
| 1.3.6.1.4.1.2011.6.164.1.5.1.5 | ScalarhwSetAcsUpperVoltLimit | read-write | current | Upper threshold of the AC voltage alarm, can be configured by users. Value range: 60 to 500, unit: V, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.5.1.6 | ScalarhwSetAcsLowerVoltLimit | read-write | current | Lower threshold of the AC voltage alarm, can be configured by users. Value range: 60 to 500, unit: V, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.5.2 | NodehwAcDistribution | |||
| 1.3.6.1.4.1.2011.6.164.1.5.2.1 | TablehwAcInputTable | not-accessible | current | AC input table. Use this table to get AC distribution unit ID, AC distribution unit name, A phase or AB line voltage, B phase or BC line voltage, C phase or CA… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1 | RowhwAcInputEntry | not-accessible | current | AC input table entry. |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.1 | ColumnhwAcInputIndex | read-only | current | ACU device table index, which value range: 1 to 100. Lines of the device list are restricted by the total quantity of ACUs (hwAcsInputQuantity). |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.2 | ColumnhwAcEquipId | read-only | current | ACU device ID, which users can configure. Value range: 004,001 to 004,100, in which The first digits indicate the device type and the last three digits indicat… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.3 | ColumnhwAcEquipName | read-write | current | ACU device name, of the character string type, is used to specify the alternating current unit (ACU). Users can configure it. Otherwise, the configured charact… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.4 | ColumnhwApOrAblVoltage | read-only | current | ACU A-phase or AB-line voltage. Value range: 0 to 500, unit: V, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.5 | ColumnhwBpOrBclVoltage | read-only | current | ACU B-phase or BC-line voltage. Value range: 0 to 500, unit: V, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.6 | ColumnhwCpOrCalVoltage | read-only | current | ACU C-phase or CA-line voltage. Value range: 0 to 500, unit: V, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.7 | ColumnhwAphaseCurrent | read-only | current | ACU A-phase current. It is an analog parameter collected by the ACU in real time. Value range: 0 to 100, unit: A, and the value is accurate to one decimal plac… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.8 | ColumnhwBphaseCurrent | read-only | current | ACU B-phase current. It is an analog parameter collected by the ACU in real time. Value range: 0 to 100, unit: A, and the value is accurate to one decimal plac… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.9 | ColumnhwCphaseCurrent | read-only | current | ACU C-phase current. It is an analog parameter collected by the ACU in real time. Value range: 0 to 100, unit: A, and the value is accurate to one decimal plac… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.10 | ColumnhwAcInputBreakersQuantity | read-only | current | Quantity of the AC air circuit breakers. As the ACU lower-level subset, the node indicates the quantity of the output air circuit breakers contained by each AC… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.99 | ColumnhwAcInputOperStatus | read-only | current | State of the site AC distribution uint. It is an enumeration type: If the enumeration value is 1, it indicates that the site AC distribution uint is in the nor… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.1.1.100 | ColumnhwAcRowStatus | read-create | current | RowStatus of ACU. |
| 1.3.6.1.4.1.2011.6.164.1.5.2.2 | TablehwAcInputBreakerTable | not-accessible | current | Ac input breaker table. Use this table to get AC input breaker equipment ID, AC input breaker equipment name, and AC input breaker status. This table's index i… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.2.1 | RowhwAcInputBreakerEntry | not-accessible | current | Ac input breaker table entry. |
| 1.3.6.1.4.1.2011.6.164.1.5.2.2.1.1 | ColumnhwAcInputBreakerIndex | read-only | current | Device table index of the AC air circuit breaker. Value range: 1 to 100. An input air circuit breaker device can be uniquely identified through the ACU table i… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.2.1.2 | ColumnhwAcInputBreakerEquipId | read-only | current | AC input air circuit breaker ID. Value range: 005,001 to 005,100. The first digits indicate the device type and the last three digits indicate the device SN. |
| 1.3.6.1.4.1.2011.6.164.1.5.2.2.1.3 | ColumnhwAcInputBreakerEquipName | read-write | current | AC input air circuit breaker name, of the character string type, can configured by users. Otherwise, the configured character can not be any other languages ex… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.2.1.99 | ColumnhwAcInputBreakerOperStatus | read-only | current | Operation state of the site AC input breaker. It is an enumeration type: If the enumeration value is 1, it indicates that the site AC input breaker is in the n… |
| 1.3.6.1.4.1.2011.6.164.1.5.2.2.1.100 | ColumnhwAcInputBreakerRowStatus | read-create | current | RowStatus of AC input breaker. |
| 1.3.6.1.4.1.2011.6.164.1.6 | NodehwSiteDcDistributions | |||
| 1.3.6.1.4.1.2011.6.164.1.6.1 | NodehwDcDistributionsGroup | |||
| 1.3.6.1.4.1.2011.6.164.1.6.1.1 | ScalarhwDcsGroupId | read-only | current | DC group ID: unique ID of the DC group. in which The first digits indicate the device type and the last three digits indicate the device SN. If the last three … |
| 1.3.6.1.4.1.2011.6.164.1.6.1.2 | ScalarhwDcsGroupName | read-write | current | Device name of the DC group, of the character string type, can be configured by users. Otherwise, the configured character can not be any other languages excep… |
| 1.3.6.1.4.1.2011.6.164.1.6.1.3 | ScalarhwDcsTotalVoltage | read-only | current | Total voltage of the DC group. Value range: 0 to 60, unit: V, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.6.1.4 | ScalarhwDcsTotalCurrent | read-only | current | Total current of the DC group. Value range: 0 to 10000, unit: A, and the value is accurate to one decimal place (.1). |
| 1.3.6.1.4.1.2011.6.164.1.6.1.5 | ScalarhwDcsTotalPower | read-only | current | Total power of the DC group. Value range: 0 to 10000, unit: W, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.6.1.6 | ScalarhwDcsTotalQuantity | read-only | current | Total quantity of the DC units, and its Value range: 0 to 100. |
| 1.3.6.1.4.1.2011.6.164.1.6.1.7 | ScalarhwSetDcsUpperVoltLimit | read-write | current | Upper threshold of the DC voltage alarm, can be configued by users. Value range: 30 to 60, unit: V, and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.6.1.8 | ScalarhwSetDcsLowerVoltLimit | read-write | current | Lower threshold of the DC voltage alarm, can be configued by users. Value range: 30 to 60, unit: V, and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.6.2 | NodehwDcDistribution | |||
| 1.3.6.1.4.1.2011.6.164.1.6.2.1 | TablehwDcOutputTable | not-accessible | current | DC output table. Use this table to get DC distribution unit ID, DC distribution unit name, DC output voltage, DC output power, and loads quantity in each DC di… |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1 | RowhwDcOutputEntry | not-accessible | current | Dc output table entry. |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1.1 | ColumnhwDcOutputIndex | read-only | current | Device table index of the DC units, which value range: 1 to 100. Lines of the device list are restricted by the total quantity of DC units (hwDcsQuantity). |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1.2 | ColumnhwDcOutputEquipId | read-only | current | DC unit device ID, which value range: 006,001 to 006,100. The first digits indicate the device type and the last three digits indicate the device SN. |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1.3 | ColumnhwDcOutputEquipName | read-write | current | DC unit device name, of the character string type, can be configued by users. Otherwise, the configured character can not be any other languages except English. |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1.4 | ColumnhwDcOutputVoltage | read-only | current | DC output voltage. It is an analog parameter collected by the DC power in real time. Value range: 0 to 60, unit: V, and the value is accurate to one decimal sp… |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1.5 | ColumnhwDcOutputCurrent | read-only | current | DC output current. It is an analog parameter collected by the DC power in real time. Value range: 0 to 10000, unit: A, and the value is accurate to one decimal… |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1.6 | ColumnhwDcOutputPower | read-only | current | DC output power. It is an analog parameter collected by the DC power in real time. Value range: 0 to 600000, unit: W, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1.7 | ColumnhwLoadsQuantity | read-only | current | Quantity of the DC load output branches, which value range: 0 to 100. As the DC unit lower-level subset, the node indicates the quantity of the DC load output … |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1.99 | ColumnhwDcOutputOperStatus | read-only | current | State of the site DC distribution uint. It is an enumeration type: If the enumeration value is 1, it indicates that the site DC distribution uint is in the nor… |
| 1.3.6.1.4.1.2011.6.164.1.6.2.1.1.100 | ColumnhwDcOutputRowStatus | read-create | current | RowStatus of Dc output equipments. |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2 | TablehwLoadBranchTable | not-accessible | current | Loads output table. Use this table to get load branch equipment ID, load branch equipment name, load branch current, and load branch power. This table's index … |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1 | RowhwLoadBranchEntry | not-accessible | current | Loads output table entry. |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.1 | ColumnhwLoadBranchIndex | read-only | current | Device table index of the DC load output branch, which value range: 1 to 100. A DC load output branch can be uniquely identified through the DC unit table inde… |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.2 | ColumnhwLoadBranchEquipId | read-only | current | Device ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of… |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.3 | ColumnhwLoadBranchEquipName | read-write | current | Device name of the DC load output branch, of the character string type, can be configured by users. Otherwise, the configured character can not be any other la… |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.4 | ColumnhwLoadBranchCurrent | read-only | current | DC load output branch current. It is an analog parameter collected by the load branch in real time. Value range: 0 to 10000, unit: A, and the value is accurate… |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.5 | ColumnhwLoadBranchPower | read-only | current | DC load branch power. It is an analog parameter collected by the DC power in real time. Value range: 0 to 600000, unit: W, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.99 | ColumnhwLoadBranchOperStatus | read-only | current | State of the site load output branch. It is an enumeration type: If the enumeration value is 1, it indicates that the site load output branch is in the normal … |
| 1.3.6.1.4.1.2011.6.164.1.6.2.2.1.100 | ColumnhwLoadBranchRowStatus | read-create | current | RowStatus of loads output branch. |
| 1.3.6.1.4.1.2011.6.164.1.7 | NodehwLvdUnits | |||
| 1.3.6.1.4.1.2011.6.164.1.7.1 | NodehwLvdsGroup | |||
| 1.3.6.1.4.1.2011.6.164.1.7.1.1 | ScalarhwLvdsGroupId | read-only | current | LVD unit group ID. It is the unique ID of the LVD unit group. The first digits indicate the device type. The last three digits indicate the device SN. If the l… |
| 1.3.6.1.4.1.2011.6.164.1.7.1.2 | ScalarhwLvdsGroupName | read-write | current | Low-voltage power-off unit group name, of the character string type, can be configured by users. Otherwise, the configured character can not be any other langu… |
| 1.3.6.1.4.1.2011.6.164.1.7.1.3 | ScalarhwLvdsTotalQuantity | read-only | current | Total quantity of power-off units. Value range: 0 to 100. |
| 1.3.6.1.4.1.2011.6.164.1.7.2 | NodehwLvdUnit | |||
| 1.3.6.1.4.1.2011.6.164.1.7.2.1 | TablehwLvdBranchTable | not-accessible | current | Power-off unit table. Use this table to get Lvd unit equipment ID and power-off unit equipment name, set power-off enable and power-off voltage, as well as con… |
| 1.3.6.1.4.1.2011.6.164.1.7.2.1.1 | RowhwLvdBranchEntry | not-accessible | current | Power-off table entry. |
| 1.3.6.1.4.1.2011.6.164.1.7.2.1.1.1 | ColumnhwLvdBranchIndex | read-only | current | Device table index of a power-off unit. Value range: 1 to 100. Lines of the device list are restricted by the total quantity of the power-off units (hwLvdsTota… |
| 1.3.6.1.4.1.2011.6.164.1.7.2.1.1.2 | ColumnhwLvdUnitEquipId | read-only | current | Device ID of a power-off unit. Value range: 8001 to 8100. The first digits indicate the device type and the last three digits indicate the device SN. |
| 1.3.6.1.4.1.2011.6.164.1.7.2.1.1.3 | ColumnhwLvdUnitEquipName | read-write | current | Device name of a power-off unit, of the character string type, is used to specify the low-voltage power-off unit. Users can configure it. Otherwise, the config… |
| 1.3.6.1.4.1.2011.6.164.1.7.2.1.1.4 | ColumnhwSetLvdEnable | read-write | current | Control power-off unit enabling. It is an enumeration value, and users actively set it. If the enumeration value is 1, it means to enable the power-off unit; I… |
| 1.3.6.1.4.1.2011.6.164.1.7.2.1.1.5 | ColumnhwSetLvdVoltage | read-write | current | Low-voltage power-off voltage of a power-off unit can be configured by users. Its value range: 35 to 60, unit: V, and the value is accurate to one decimal spac… |
| 1.3.6.1.4.1.2011.6.164.1.7.2.1.1.6 | ColumnhwCtrlLvd | read-write | current | Control of the power-off unit. It is an enumeration value, users control it manually. If the NMS notifies the SNMP agent that the node is set to 1, it means to… |
| 1.3.6.1.4.1.2011.6.164.1.7.2.1.1.99 | ColumnhwLvdBranchOperStatus | read-only | current | State of the site LVD uint. It is an enumeration type: If the enumeration value is 1, it indicates that the site LVD uint is in the normal state; If the enumer… |
| 1.3.6.1.4.1.2011.6.164.1.7.2.1.1.100 | ColumnhwLvdBranchRowStatus | read-create | current | RowStatus of lvd table. |
| 1.3.6.1.4.1.2011.6.164.1.8 | NodehwSiteEnvUnits | |||
| 1.3.6.1.4.1.2011.6.164.1.8.1 | NodehwEnvUnitsGroup | |||
| 1.3.6.1.4.1.2011.6.164.1.8.1.1 | ScalarhwEnvUnitsGroupId | read-only | current | Unit group ID of the site environment. It is the unique ID of the unit group on the site. The first digits indicate the device type. The last three digits indi… |
| 1.3.6.1.4.1.2011.6.164.1.8.1.2 | ScalarhwEnvUnitsGroupName | read-write | current | Unit group name of the site environment, of the character string type, can be configured by users. Otherwise, the configured character can not be any other lan… |
| 1.3.6.1.4.1.2011.6.164.1.8.1.3 | ScalarhwCtrlSmokeReset | read-write | current | Smoke sensor reset. It manually controls clearance of the smoke sensor alarm, and this node is of the enumeration type. If the enumeration value is 1, it indic… |
| 1.3.6.1.4.1.2011.6.164.1.8.1.4 | ScalarhwCtrlDoorReset | read-write | current | Door actuator reset control. It manually controls clearance of the door actuator alarm. This node is of the enumeration type. If the enumeration value is 1, it… |
| 1.3.6.1.4.1.2011.6.164.1.8.1.5 | ScalarhwCtrlBuzzerEnable | read-write | current | Buzzer enabling. It manually controls the enabling of the buzzer alarm. This node is of the enumeration type. When the enumeration value is 1, it means to enab… |
| 1.3.6.1.4.1.2011.6.164.1.8.1.6 | ScalarhwEnvTempSensorsTotalQuantity | read-only | current | Quantity of the environment temperature sensors, and its value range: 0 to 256. |
| 1.3.6.1.4.1.2011.6.164.1.8.1.7 | ScalarhwEnvHumiSensorsTotalQuantity | read-only | current | Quantity of the environment humidity sensors, and its value range: 0 to 256. |
| 1.3.6.1.4.1.2011.6.164.1.8.1.8 | ScalarhwSpareDigitalsTotalQuantity | read-only | current | Quantity of the Spare digitals, and its value range: 0 to 256. |
| 1.3.6.1.4.1.2011.6.164.1.8.2 | NodehwEnvSensor | |||
| 1.3.6.1.4.1.2011.6.164.1.8.2.1 | TablehwEnvTempSensorTable | not-accessible | current | Site environment temperature table. Use this table to get environment temperature equipment ID, environment temperature equipment name, and environment tempera… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1 | RowhwEnvTempSensorEntry | not-accessible | current | Site environment temperature table entry. |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.1 | ColumnhwEnvTempSensorIndex | read-only | current | Table index of the environment temperature sensors. Value range: 1 to 256. Lines of the device table are restricted by the quantity of environment temperature … |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.2 | ColumnhwEnvTempEquipId | read-only | current | Environment temperature sensor ID. Value range: 009'001 to 009'255, in which the first digits indicate the device type and the last three digits indicate the d… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.3 | ColumnhwEnvTempEquipName | read-write | current | Environment temperature sensor name, of the character string type, is used to specify an environment temperature sensor. Users can configure it. Otherwise, the… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.4 | ColumnhwEnvTemperature | read-only | current | Environment temperature. It is an environment parameter collected in real time. Value range: -50 to +100, unit: centigrade (°„C), and the value is an intege… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.5 | ColumnhwSetEnvTempUpperLimit | read-write | current | Upper threshold of the environment temperature alarm, can be configured by users. Value range: -50 to 100, unit: centigrade (°„C), and the value is an integ… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.6 | ColumnhwSetEnvTempLowerLimit | read-write | current | Lower threshold of the environment temperature alarm, can be configured by users. Value range: -50 to 100, unit: centigrade (°„C), and the value is an integ… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.7 | ColumnhwSetEnvTempMeasureUpperLimit | read-write | current | Upper threshold of the environment temperature measurement, can be configured by users. Value range: 0 to 100, unit: centigrade (°„C), and the value is an i… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.8 | ColumnhwSetEnvTempMeasureLowerLimit | read-write | current | Lower threshold of the environment temperature measurement, can be configured by users. Value range: -50 to 0, unit: centigrade (°„C), and the value is an i… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.9 | ColumnhwSetEnvTempAlarmEnable | read-write | current | Environment temperature alarm. It is an enumeration type: If the enumeration value is 1, enable the alarm of the environment temperature; If the enumeration va… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.99 | ColumnhwEnvTempSensorOperStatus | read-only | current | State of the site environment temperature sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site environment temperature … |
| 1.3.6.1.4.1.2011.6.164.1.8.2.1.1.100 | ColumnhwEnvTempSensorRowStatus | read-create | current | RowStatus of Environment temperature table. |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2 | TablehwEnvHumiSensorTable | not-accessible | current | Environment humidity table. Use this table to get environment humidity equipment ID , environment humidity equipment name, and environment humidity, set enviro… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1 | RowhwEnvHumiSensorEntry | not-accessible | current | Environment humidity table entry. |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.1 | ColumnhwEnvHumiSensorIndex | read-only | current | Table index of the environment humility sensors. Value range: 1 to 256. Lines of the device list are restricted by the quantity of environment humility sensors… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.2 | ColumnhwEnvHumiEquipId | read-only | current | Environment humility sensor ID, can be configured by users. Value range: 010'001 to 010'255, in which the first digits indicate the device type and the last th… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.3 | ColumnhwEnvHumiEquipName | read-write | current | Environment humility sensor name, of the character string type, is used to specify an environment humility sensor. Users can configure it. Otherwise, the confi… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.4 | ColumnhwEnvHumidity | read-only | current | Environment humility. It is an environment parameter collected in real time. Value range: 0 to 100, unit: %RH, and the value is an integer (.0). If the value i… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.5 | ColumnhwSetEnvHumidityUpperLimit | read-write | current | Upper threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, unit: %RH, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.6 | ColumnhwSetEnvHumidityLowerLimit | read-write | current | Lower threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, unit: %RH, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.7 | ColumnhwSetEnvHumidityMeasureUpperLimit | read-write | current | Upper threshold of the environment humility measurement, can be configured by users. Value range: 0 to 100, unit: %RH, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.8 | ColumnhwSetEnvHumidityMeasureLowerLimit | read-write | current | Lower threshold of the environment humility measurement, can be configured by users. Value range: 0 to 100, unit: %RH, and the value is an integer (.0). |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.9 | ColumnhwSetEnvHumiAlarmEnable | read-write | current | Environment humility alarm. It is an enumeration type: If the enumeration value is 1, enable the alarm of the environment humility; If the enumeration value is… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.99 | ColumnhwEnvHumiSensorOperStatus | read-only | current | State of the site environment humidity sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site environment humidity sensor… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.2.1.100 | ColumnhwEnvHumiSensorRowStatus | read-create | current | RowStatus of Environment humidity table. |
| 1.3.6.1.4.1.2011.6.164.1.8.2.3 | TablehwSpareDigitalTable | not-accessible | current | Spare digital table. Use this table to get Spare digital equipment ID , Spare digital equipment name, and current Spare digital alarm tension, ae well as to se… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.3.1 | RowhwSpareDigitalEntry | not-accessible | current | Spare digital table entry. |
| 1.3.6.1.4.1.2011.6.164.1.8.2.3.1.1 | ColumnhwSpareDigitalIndex | read-only | current | Spare digital table index, which value range: 1 to 256. Lines of the device list are restricted by the quantity of Spare digitals (hwSpareDigitalsTotalQuantity… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.3.1.2 | ColumnhwSpareDigitalEquipId | read-only | current | Spare digital device ID. Value range: 011'001 to 011'255, in which the first digits indicate the device type and the last three digits indicate the device SN. |
| 1.3.6.1.4.1.2011.6.164.1.8.2.3.1.3 | ColumnhwSpareDigitalEquipName | read-write | current | Spare digital name, of the character string type, is used to specify Spare digitals. Users can configure it. Otherwise, the configured character can not be any… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.3.1.4 | ColumnhwSetSpareDigitalAlarmTension | read-write | current | Spare digital alarm state. It is an enumeration value. If the value of the node is 0, it indicates a low-tension alarm; If the value of the node is 1, it indic… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.3.1.5 | ColumnhwSetSpareDigitalAlarmEnable | read-write | current | Spare digital alarm enabling. It is an enumeration type: If the enumeration value is 1, it means to enable the alarm; If the enumeration value is 2, it means t… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.3.1.99 | ColumnhwSpareDigitalOperStatus | read-only | current | State of the site Spare digital. It is an enumeration type: If the enumeration value is 1, it indicates that the Spare digital operation state is normal; If th… |
| 1.3.6.1.4.1.2011.6.164.1.8.2.3.1.100 | ColumnhwSpareDigitalRowStatus | read-create | current | RowStatus of Spare digital device table. |
| 1.3.6.1.4.1.2011.6.164.1.9 | NodehwSitePDEs | |||
| 1.3.6.1.4.1.2011.6.164.1.9.1 | NodehwPDEGroup | |||
| 1.3.6.1.4.1.2011.6.164.1.9.1.1 | ScalarhwPDEGroupId | read-only | current | PDE unit group ID. It is the unique ID of the PDE unit group. The first digits indicate the device type. The last three digits indicate the device SN. If the l… |
| 1.3.6.1.4.1.2011.6.164.1.9.1.2 | ScalarhwPDEGroupName | read-write | current | PDE unit group name, of the character string type, can be configured by users. Otherwise, the configured character can not be any other languages except Englis… |
| 1.3.6.1.4.1.2011.6.164.1.9.1.3 | ScalarhwPDEGroupNum | read-only | current | PDE Num,Value range: 0 to 100. |
| 1.3.6.1.4.1.2011.6.164.1.9.1.4 | ScalarhwPDEGroupCommNum | read-only | current | Communication PDE Num,Value range: 0 to 100. |
| 1.3.6.1.4.1.2011.6.164.1.9.1.5 | ScalarhwPDEGroupTotalPower | read-only | current | PDE Total Power,Value range: 0.0 to 10000.0.Unit: W.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.1.6 | ScalarhwPDEGroupTotalCurrent | read-only | current | PDE Total Current,Value range: 0.0 to 300.0.Unit: A.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.1.7 | ScalarhwPDEGroupCommStatus | read-only | current | PDE Communication Status. It is an enumeration type: If the enumeration value is 1, it indicates that communication is normal; If the enumeration value is 2, i… |
| 1.3.6.1.4.1.2011.6.164.1.9.3 | NodehwPDE | |||
| 1.3.6.1.4.1.2011.6.164.1.9.3.1 | TablehwPDETable | not-accessible | current | PDE table. Use this table to get PDE equipment ID , PDE equipment name, and current PDE status. This table's index is hwPDEIndex. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1 | RowhwPDEEntry | not-accessible | current | PDE table entry. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.1 | ColumnhwPDEIndex | read-only | current | PDE table index, which value range: 1 to 10. Lines of the device list are restricted by the quantity of PDE. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.2 | ColumnhwPDEEquipId | read-only | current | PDE device ID. Value range: 012'001 to 012'255, in which the first digits indicate the device type and the last three digits indicate the device SN. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.3 | ColumnhwPDEEquipName | read-write | current | PDE name, of the character string type, is used to specify PDEs. Users can configure it. Otherwise, the configured character can not be any other languages exc… |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.4 | ColumnhwPDETotalRunningTime | read-only | current | PDE Total Running Time,Value range: 0 to 876000.Unit: H. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.5 | ColumnhwPDEBranchNum | read-only | current | PDE Branch Number,Value range: 0 to 6. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.6 | ColumnhwPDETotalPower | read-only | current | PDE Total Power,Value range: 0.0 to 10000.0.Unit: W.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.7 | ColumnhwPDETotalCurrent | read-only | current | PDE Total Current,Value range: 0.0 to 30000.0.Unit: A.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.8 | ColumnhwPDEBranch1Power | read-only | current | PDE Branch1 Power,Value range: 0.0 to 100000.0.Unit: W.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.9 | ColumnhwPDEBranch2Power | read-only | current | PDE Branch2 Power,Value range: 0.0 to 100000.0.Unit: W.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.10 | ColumnhwPDEBranch3Power | read-only | current | PDE Branch3 Power,Value range: 0.0 to 100000.0.Unit: W.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.11 | ColumnhwPDEBranch4Power | read-only | current | PDE Branch4 Power,Value range: 0.0 to 100000.0.Unit: W.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.12 | ColumnhwPDEBranch1Current | read-only | current | PDE Branch1 Current,Value range: 0.0 to 1000.0.Unit: A.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.13 | ColumnhwPDEBranch2Current | read-only | current | PDE Branch2 Current,Value range: 0.0 to 1000.0.Unit: A.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.14 | ColumnhwPDEBranch3Current | read-only | current | PDE Branch3 Current,Value range: 0.0 to 1000.0.Unit: A.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.15 | ColumnhwPDEBranch4Current | read-only | current | PDE Branch4 Current,Value range: 0.0 to 1000.0.Unit: A.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.16 | ColumnhwPDEBranch1Voltage | read-only | current | PDE Branch1 Voltage,Value range: 0.0 to 65.0.Unit: V.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.17 | ColumnhwPDEBranch2Voltage | read-only | current | PDE Branch2 Voltage,Value range: 0.0 to 65.0.Unit: V.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.18 | ColumnhwPDEBranch3Voltage | read-only | current | PDE Branch3 Voltage,Value range: 0.0 to 65.0.Unit: V.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.19 | ColumnhwPDEBranch4Voltage | read-only | current | PDE Branch4 Voltage,Value range: 0.0 to 65.0.Unit: V.and the value is accurate to one decimal space (.1). |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.20 | ColumnhwPDEBranch1Temperature | read-only | current | PDE Branch1 Temperature,Value range: 0 to 300.Unit: deg. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.21 | ColumnhwPDEBranch2Temperature | read-only | current | PDE Branch2 Temperature,Value range: 0 to 300.Unit: deg. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.22 | ColumnhwPDEBranch3Temperature | read-only | current | PDE Branch3 Temperature,Value range: 0 to 300.Unit: deg. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.23 | ColumnhwPDEBranch4Temperature | read-only | current | PDE Branch4 Temperature,Value range: 0 to 300.Unit: deg. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.24 | ColumnhwPDEOperStatus | read-only | current | State of the PDE. It is an enumeration type: If the enumeration value is 1, it indicates that the PDE is in the normal state; If the enumeration value is 2, it… |
| 1.3.6.1.4.1.2011.6.164.1.9.3.1.1.100 | ColumnhwPDERowStatus | read-create | current | RowStatus of PDE table. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2 | TablehwPDEConfigTable | not-accessible | current | PDE Config table. Use this table to get PDE equipment ID , PDE equipment name, and current PDE config parameter. This table's index is hwPDEConfigIndex. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1 | RowhwPDEConfigEntry | not-accessible | current | PDE Config table entry. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.1 | ColumnhwPDEConfigIndex | read-only | current | PDE Config table index, which value range: 1 to 10. Lines of the device list are restricted by the quantity of PDE. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.2 | ColumnhwPDEConfigEquipId | read-only | current | PDE device ID. Value range: 012'001 to 012'255, in which the first digits indicate the device type and the last three digits indicate the device SN. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.3 | ColumnhwPDEConfigEquipName | read-write | current | PDE name, of the character string type, is used to specify PDEs. Users can configure it. Otherwise, the configured character can not be any other languages exc… |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.4 | ColumnhwPDEOverTempProtect | read-write | current | PDE Over Temperature Protect,Value range: 100 to 120.Unit: deg. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.5 | ColumnhwPDEVolProtectEnable | read-write | current | PDE Over Protect Enable,It is an enumeration value, and users actively set it. If the enumeration value is 1, it means to enable the PDE voltage protect; If th… |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.6 | ColumnhwPDEOverVoltageProtect | read-write | current | PDE Over Voltage Protect,Value range: 58 to 60.Unit: V. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.7 | ColumnhwPDEUnderVoltageProtect | read-write | current | PDE Under Voltage Protect,Value range: 40 to 48.Unit: V. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.8 | ColumnhwPDEHysteresis | read-write | current | PDE Hysteresis,Value range: 1 to 3.Unit: V. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.9 | ColumnhwPDEReset | read-write | current | PDE Reset Control,It is an enumeration value, and users actively set it. If the enumeration value is 1, it means to reset the PDE; |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.10 | ColumnhwPDEBranch1Control | read-write | current | PDE Branch1 Control,It is an enumeration value, and users actively set it. If the enumeration value is 1, it means to open the branch1; If the enumeration valu… |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.11 | ColumnhwPDEBranch2Control | read-write | current | PDE Branch2 Control,It is an enumeration value, and users actively set it. If the enumeration value is 1, it means to open the branch2; If the enumeration valu… |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.12 | ColumnhwPDEBranch3Control | read-write | current | PDE Branch3 Control,It is an enumeration value, and users actively set it. If the enumeration value is 1, it means to open the branch3; If the enumeration valu… |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.13 | ColumnhwPDEBranch4Control | read-write | current | PDE Branch4 Control,It is an enumeration value, and users actively set it. If the enumeration value is 1, it means to open the branch4; If the enumeration valu… |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.14 | ColumnhwPDEBranch1CurrentLimit | read-write | current | PDE Branch1 Current Limit,Value range: 1 to 20.Unit: A. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.15 | ColumnhwPDEBranch2CurrentLimit | read-write | current | PDE Branch2 Current Limit,Value range: 1 to 30.Unit: A. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.16 | ColumnhwPDEBranch3CurrentLimit | read-write | current | PDE Branch3 Current Limit,Value range: 1 to 30.Unit: A. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.17 | ColumnhwPDEBranch4CurrentLimit | read-write | current | PDE Branch4 Current Limit,Value range: 1 to 20.Unit: A. |
| 1.3.6.1.4.1.2011.6.164.1.9.3.2.1.100 | ColumnhwPDEConfigRowStatus | read-create | current | RowStatus of PDE config table. |
| 1.3.6.1.4.1.2011.6.164.2 | NodehwSiteMonitorMIBTraps | |||
| 1.3.6.1.4.1.2011.6.164.2.1 | NodehwSiteAlarmTraps | |||
| 1.3.6.1.4.1.2011.6.164.2.1.0 | NodehwSiteAlarmTrapsPrefix | |||
| 1.3.6.1.4.1.2011.6.164.2.1.0.1 | NotificationhwRectifierFaultAlarmTraps | current | When rectifiers fault alarms happen, a alarm trap will be send. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Al… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.2 | NotificationhwRectifierFaultAlarmResumeTraps | current | Rectifier Fault alarm resolved.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm por… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.3 | NotificationhwRectifierAbnormalAlarmTraps | current | Rectifier abnormal alarm, because of communication failure, module protection, or turnoff. Its correlation binding parameters: Site ID, Site name, Site descrip… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.4 | NotificationhwRectifierAbnormalAlarmResumeTraps | current | Rectifier abnormal alarm resume. Description.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descript… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.5 | NotificationhwBattLoopBreakAlarmTraps | current | Battery loop disconnect. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port desc… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.6 | NotificationhwBattLoopBreakAlarmResumeTraps | current | Battery loop break alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm p… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.7 | NotificationhwBattLvdAlarmTraps | current | Battery disconnect for low voltage. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alar… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.8 | NotificationhwBattLvdAlarmResumeTraps | current | Battery LVD alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port des… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.9 | NotificationhwBattOverCurrAlarmTraps | current | Batterys charge in over current. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm p… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.10 | NotificationhwBattOverCurrAlarmResumeTraps | current | Batterys over current alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alar… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.11 | NotificationhwBattStringTempAlarmTraps | current | Battery string temperature is too high or too low. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single de… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.12 | NotificationhwBattStringTempAlarmResumeTraps | current | Battery string temperature alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description,… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.13 | NotificationhwBattDischargeAlarmTraps | current | Battery group discharge alarm. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm por… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.14 | NotificationhwBattDischargeAlarmResumeTraps | current | Battery group discharge alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Al… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.15 | NotificationhwAcInputAlarmTraps | current | AC absent or AC power off alarms happened. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descriptio… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.16 | NotificationhwAcInputAlarmResumeTraps | current | AC input alarm resumed. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descr… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.17 | NotificationhwAcVoltAlarmTraps | current | AC voltage too high or too low. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm po… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.18 | NotificationhwAcVoltAlarmResumeTraps | current | AC voltage alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port desc… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.19 | NotificationhwDcVoltAlarmTraps | current | DC voltage too high or too low. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm po… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.20 | NotificationhwDcVoltAlarmResumeTraps | current | DC voltage alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port desc… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.21 | NotificationhwLoadLvdAlarmTraps | current | Loads disconnect for low voltage. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm … | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.22 | NotificationhwLoadLvdAlarmResumeTraps | current | Load LVD alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descri… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.23 | NotificationhwLoadFuseAlarmTraps | current | Load fuse broken down. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descri… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.24 | NotificationhwLoadFuseAlarmResumeTraps | current | Load fuse alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descr… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.25 | NotificationhwEnvTempAlarmTraps | current | Environment temperature is too high or too low. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descr… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.26 | NotificationhwEnvTempAlarmResumeTraps | current | Environment temperature alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Al… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.27 | NotificationhwEnvHumiAlarmTraps | current | Environment humidity is too high or too low. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descript… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.28 | NotificationhwEnvHumiAlarmResumeTraps | current | Environment humidity alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.29 | NotificationhwSpareDigitalAlarmTraps | current | Spare digital fault. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descript… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.30 | NotificationhwSpareDigitalAlarmResumeTraps | current | Spare digital alarm resume.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port de… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.31 | NotificationhwDoorAlarmTraps | current | Door open. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description, Alarm… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.32 | NotificationhwDoorAlarmResumeTraps | current | Door alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descriptio… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.33 | NotificationhwWaterAlarmTraps | current | Water alarm. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description, Ala… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.34 | NotificationhwWaterAlarmResumeTraps | current | Water alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descripti… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.35 | NotificationhwSmokeAlarmTraps | current | Site is on fire, which is detected by smoke sensors. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single … | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.36 | NotificationhwSmokeAlarmResumeTraps | current | Smoke alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descripti… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.37 | NotificationhwWireAlarmTraps | current | Wire alarm.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description, Alarm… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.38 | NotificationhwWireAlarmResumeTraps | current | Wire alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descriptio… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.39 | NotificationhwAcBreakerAlarmTraps | current | AC breaker alarm.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port description,… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.40 | NotificationhwAcBreakerAlarmResumeTraps | current | AC breaker alarm resume.Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descr… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.41 | NotificationhwMultiRectFailureAlarmTraps | current | More than one rectifier reported fault alarms in the same time. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Al… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.42 | NotificationhwMultiRectFailureAlarmResumeTraps | current | Multi-rectifiers fault alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Ala… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.43 | NotificationhwRectRedundAlarmTraps | current | Rectifiers work redundantly, in this case that some of rectifiers will going to sleep. Its correlation binding parameters: Site ID, Site name, Site description… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.44 | NotificationhwRectRedundAlarmResumeTraps | current | Rectifiers redundant alarm resume, when the power supply and requirement were in balance. Its correlation binding parameters: Site ID, Site name, Site descript… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.45 | NotificationhwBattUnbalanceAlarmTraps | current | Battery works in unbalance state. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm … | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.46 | NotificationhwBattUnbalanceAlarmResumeTraps | current | Battery unbalance alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm po… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.47 | NotificationhwAcFreqFaultAlarmTraps | current | AC frequency is fault. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descri… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.48 | NotificationhwAcFreqFaultAlarmResumeTraps | current | AC frequency alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port de… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.49 | NotificationhwXmuSelfFaultAlarmTraps | current | There are some fault in XMU itself. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alar… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.50 | NotificationhwXmuSelfFaultAlarmResumeTraps | current | XMU fault alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm port descr… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.51 | NotificationhwRs485CommAlarmTraps | current | RS485 communication of monitors disconnect. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descripti… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.52 | NotificationhwRs485CommAlarmResumeTraps | current | RS485 communication alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alarm … | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.53 | NotificationhwNetCommAlarmTraps | current | Network communication of monitors disconnect. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descrip… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.54 | NotificationhwNetCommAlarmResumeTraps | current | Network communication alarm resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single description, Alar… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.55 | NotificationhwAcOffLongTimeAlarmTraps | current | AC power off for a long time alarms happened. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descrip… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.56 | NotificationhwAcOffLongTimeAlarmResumeTraps | current | AC power off for a long time alarms resume. Its correlation binding parameters: Site ID, Site name, Site description, NE ID, Alarm name, Alarm single descripti… | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.57 | NotificationhwSpdAlarmTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.58 | NotificationhwSpdAlarmResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.59 | NotificationhwBadBatteryTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.60 | NotificationhwBadBatteryResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.61 | NotificationhwLvd2DisconnectingTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.62 | NotificationhwLvd2DisconnectingResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.63 | NotificationhwBattHighTempTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.64 | NotificationhwBattHighTempResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.65 | NotificationhwBattLowTempTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.66 | NotificationhwBattLowTempResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.67 | NotificationhwDcUltraOverVoltageTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.68 | NotificationhwDcUltraOverVoltageResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.69 | NotificationhwDcUltraUnderVoltageTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.70 | NotificationhwDcUltraUnderVoltageResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.71 | NotificationhwUmiCommFailTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.72 | NotificationhwUmiCommFailResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.73 | NotificationhwShortTestFailTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.74 | NotificationhwShortTestFailResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.75 | NotificationhwMissingBattTempSensorTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.76 | NotificationhwMissingBattTempSensorResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.77 | NotificationhwBattTempSensorFaultTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.78 | NotificationhwBattTempSensorFaultResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.79 | NotificationhwAcOverVoltageTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.80 | NotificationhwAcOverVoltageResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.81 | NotificationhwAcUnderVoltageTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.82 | NotificationhwAcUnderVoltageResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.83 | NotificationhwPDELoadFaultTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.84 | NotificationhwPDELoadFaultResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.85 | NotificationhwPDENoResponseTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.86 | NotificationhwPDENoResponseResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.87 | NotificationhwPDEFailureTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.88 | NotificationhwPDEFailureResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.89 | NotificationhwPDEBr1FailureTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.90 | NotificationhwPDEBr1FailureResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.91 | NotificationhwPDEBr2FailureTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.92 | NotificationhwPDEBr2FailureResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.93 | NotificationhwPDEBr3FailureTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.94 | NotificationhwPDEBr3FailureResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.95 | NotificationhwPDEBr4FailureTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.96 | NotificationhwPDEBr4FailureResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.97 | NotificationhwPDEBr1ProtectTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.98 | NotificationhwPDEBr1ProtectResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.99 | NotificationhwPDEBr2ProtectTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.100 | NotificationhwPDEBr2ProtectResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.101 | NotificationhwPDEBr3ProtectTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.102 | NotificationhwPDEBr3ProtectResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.103 | NotificationhwPDEBr4ProtectTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.104 | NotificationhwPDEBr4ProtectResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.105 | NotificationhwPDELostTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.1.0.106 | NotificationhwPDELostResumeTraps | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.2.2 | NodehwSiteDevicesTraps | |||
| 1.3.6.1.4.1.2011.6.164.2.2.0 | NodehwDevicesTrapsPrefix | |||
| 1.3.6.1.4.1.2011.6.164.2.3 | NodehwV101SiteDevicesTraps | |||
| 1.3.6.1.4.1.2011.6.164.2.3.1 | NodehwV101DevicesTrapsPrefix | |||
| 1.3.6.1.4.1.2011.6.164.2.3.1.1 | NotificationhwRectifiersInslotChange | current | When the presence status of a rectifier changes, the node reports an event. Then the NMS adds or deletes the corresponding entry to or from hwRectConfigTable o… | |
| 1.3.6.1.4.1.2011.6.164.2.3.1.2 | NotificationhwBatterysInslotChange | current | When the presence status of a battery string changes, the node reports an event. Then the NMS adds or deletes the corresponding entry to or from hwBatttConfigT… | |
| 1.3.6.1.4.1.2011.6.164.2.3.1.3 | NotificationhwBattTestRecordsAdd | current | After a new discharge test is conducted on a battery group, the node reports an event. The bound information includes the site address, site name, site descrip… | |
| 1.3.6.1.4.1.2011.6.164.2.3.1.4 | NotificationhwEnvTempSensInslotChange | current | When the presence status of an environment temperature sensor changes, the node reports an event. Then the NMS adds or deletes the corresponding entry to or fr… | |
| 1.3.6.1.4.1.2011.6.164.2.3.1.5 | NotificationhwEnvHumiSensInslotChange | current | When the presence status of an environment humidity sensor changes, the trap reports an event. Then the NMS adds or deletes the corresponding entry to or from … | |
| 1.3.6.1.4.1.2011.6.164.2.3.1.6 | NotificationhwPDEsInslotChange | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.3 | NodehwSiteMonitorMIBConformance | |||
| 1.3.6.1.4.1.2011.6.164.3.1 | NodehwSiteMonitorGroups | |||
| 1.3.6.1.4.1.2011.6.164.3.1.1 | GrouphwSiteInfoGroup | current | Site information group. | |
| 1.3.6.1.4.1.2011.6.164.3.1.2 | GrouphwSiteMonitorsGroup | current | Site monitor group. | |
| 1.3.6.1.4.1.2011.6.164.3.1.3 | GrouphwSiteRectifiersGroup | current | Site rectifier group. | |
| 1.3.6.1.4.1.2011.6.164.3.1.4 | GrouphwSiteBatterysGroup | current | Site battery group. | |
| 1.3.6.1.4.1.2011.6.164.3.1.5 | GrouphwSiteAcDistributionsGroup | current | Site AC distribution group. | |
| 1.3.6.1.4.1.2011.6.164.3.1.6 | GrouphwSiteDcDistributionsGroup | current | Site DC distribution group. | |
| 1.3.6.1.4.1.2011.6.164.3.1.7 | GrouphwSiteLvdUnitsGroup | current | Site low voltage disconnection unit group. | |
| 1.3.6.1.4.1.2011.6.164.3.1.8 | GrouphwSiteEnvUnitsGroup | current | Site envirenment unit group. | |
| 1.3.6.1.4.1.2011.6.164.3.1.9 | GrouphwSiteAlarmTrapsGroup | current | Site alarm trap group. | |
| 1.3.6.1.4.1.2011.6.164.3.1.10 | GrouphwSiteDeviceTrapsGroup | current | Description. | |
| 1.3.6.1.4.1.2011.6.164.3.1.11 | GrouphwSiteEfusesGroup | current | Description. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DateAndTime | OCTET STRING (SIZE (8..11)) | current | Description. |
| DisplayString | OCTET STRING (SIZE (1..64)) | current | Description. |
| MeasuresRange | Integer32 | current | Description. |
| RowStatus | INTEGER { active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6) } | current | Description. |
| RunStatus | INTEGER { unknow(1), normal(2), alarm(3) } | current | This integer value represents running status of the system. Depending on situation there may be limits on allowed values. Operational values: (1) unknown - status has not yet been defined (2) normal - there are no activ… |
| TruthValue | INTEGER { true(1), flase(2) } | current | Description. |