HUAWEI-SPC-MIB
134 objects
The MIB module defines Huawei's SPC management MIB objects.
Imported Objects
| HUAWEI-MIB | huaweiUtility |
| SNMPv2-SMI | Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | RowStatus |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2011.6.15 | IdentityhwSPC | The MIB module defines Huawei's SPC management MIB objects. | ||
| 1.3.6.1.4.1.2011.6.15.1 | NodehwSpcMibObjects | |||
| 1.3.6.1.4.1.2011.6.15.1.1 | TablehwSpcMngtTable | not-accessible | current | You can add, delete, modify or query SPC using hwSpcMngtTable. The index of this table is hwSpcNo. |
| 1.3.6.1.4.1.2011.6.15.1.1.1 | RowhwSpcMngtEntry | not-accessible | current | You can add, delete, modify or query SPC using hwSpcMngtTable. The index of this entry is hwSpcNo. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.1 | ColumnhwSpcNo | accessible-for-notify | current | Index of the SPC Range: 0-2047 for MD products and 0-511 for MA products |
| 1.3.6.1.4.1.2011.6.15.1.1.1.2 | ColumnhwStartFrameID | read-create | current | Frame ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.3 | ColumnhwStartSlotID | read-create | current | Slot ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.4 | ColumnhwStartPort | read-create | current | Port ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.5 | ColumnhwStartBsn | read-create | current | Channel index of SPC's start point |
| 1.3.6.1.4.1.2011.6.15.1.1.1.6 | ColumnhwEndFrameID | read-create | current | Shelf ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB. The value 255 indicates that this parameter is not used. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.7 | ColumnhwEndSlotID | read-create | current | Slot ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB. The value 255 indicates that this parameter is not used. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.8 | ColumnhwEndPort | read-create | current | Port ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB. The value 255 indicates that this parameter is not used. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.9 | ColumnhwEndBsn | read-create | current | Channel index of SPC's end point. The value 255 indicates that this parameter is not used. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.10 | ColumnhwChannelNum | read-create | current | Total channels occupied by the SPC. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.11 | ColumnhwApptype | read-create | current | Applied type of SPC. Options: 1. normal(1) -normal application 2. hotline(2) -hotline application 3. mChannelTransparent(3) -M channel transparent 4. pbxExtent… |
| 1.3.6.1.4.1.2011.6.15.1.1.1.12 | ColumnhwSpctype | read-create | current | Configuration type of SPC. Options: 1. anSpc(1) -Internal SPC 2. v5Spc(2) -V5 SPC 3. v5Preconnect(3) -V5 pre-connection SPC 4. private(4) -leased line SPC 5. i… |
| 1.3.6.1.4.1.2011.6.15.1.1.1.13 | ColumnhwStartPortSubType | read-create | current | Sub type of SPC's start port. If the SPC is used for PHS, the type must be set to mnt or mlt. Options: 1. noSubType(255) -no sub type 2. mnt(1) -mnt 3. mlt(2) … |
| 1.3.6.1.4.1.2011.6.15.1.1.1.14 | ColumnhwEndPortSubType | read-create | current | Sub type of SPC's end port. This node is not used on the OLT. Options: 1. noSubType(255) -no sub type 2. mnt(1) -mnt 3. mlt(2) -mlt |
| 1.3.6.1.4.1.2011.6.15.1.1.1.15 | ColumnhwPathProtect | read-create | current | Enable path protection. This leaf is not used on the OLT. Options: 1. yes(1) -YES 2. no(2) -NO |
| 1.3.6.1.4.1.2011.6.15.1.1.1.16 | ColumnhwSPCName | read-write | current | Name of SPC. It contains 31 characters. - means it is not configured. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.17 | ColumnhwSpcState | read-only | current | SPC state. Options: 1. idle(1) -idle 2. normal(2) -normal 3. error(3) -error 4. errorChecking(4) -error checking 5. occupying(5) -occupying 6. checking(6) -che… |
| 1.3.6.1.4.1.2011.6.15.1.1.1.18 | ColumnhwFailCause | read-only | current | Fault reason of SPC. Options: 1. startBusy(1) -the start port is busy 2. endBusy(2) - the end port is busy 3. startFault(3) - the start port is fault 4. endFau… |
| 1.3.6.1.4.1.2011.6.15.1.1.1.19 | ColumnhwOprType | read-write | current | Operate type of SPC. It can be set to disconnect or connect. Options: 1. noOperation(1) -no operation 2. connect(2) -connect 3. disconnect(3) -disconnect |
| 1.3.6.1.4.1.2011.6.15.1.1.1.20 | ColumnhwRowStatus | read-write | current | Row status. It supports only CreateAndGo(4) and Destroy(6). |
| 1.3.6.1.4.1.2011.6.15.1.1.1.21 | ColumnhwStartCESFrame | read-only | current | Start CES shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.22 | ColumnhwStartCESSlot | read-only | current | CES slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.23 | ColumnhwStartCESPort | read-only | current | Start CES port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.24 | ColumnhwStartUpPv8Frame | read-only | current | Start upstream PV8 shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.25 | ColumnhwStartUpPv8Slot | read-only | current | Start upstream PV8 slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.26 | ColumnhwStartUpPv8Port | read-only | current | Start upstream PV8 port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.27 | ColumnhwStartDownPv8Frame | read-only | current | Start downstream PV8 shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.28 | ColumnhwStartDownPv8Slot | read-only | current | Start downstream PV8 slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.29 | ColumnhwStartDownPv8Port | read-only | current | Start downstream PV8 port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.30 | ColumnhwStartRspFrame | read-only | current | Start downstream RSP shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.31 | ColumnhwStartRspSlot | read-only | current | Start downstream RSP slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.32 | ColumnhwStartRspPort | read-only | current | Start downstream RSP port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.33 | ColumnhwEndtCESFrame | read-only | current | End downstream CES shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.34 | ColumnhwEndCESSlot | read-only | current | End downstream CES slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.35 | ColumnhwEndCESPort | read-only | current | End CES port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.36 | ColumnhwEndUpPv8Frame | read-only | current | End upstream PV8 shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.37 | ColumnhwEndUpPv8Slot | read-only | current | End upstream PV8 slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.38 | ColumnhwEndUpPv8Port | read-only | current | End upstream PV8 port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.39 | ColumnhwEndDownPv8Frame | read-only | current | End downstream PV8 shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.40 | ColumnhwEndDownPv8Slot | read-only | current | End downstream PV8 slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.41 | ColumnhwEndDownPv8Port | read-only | current | End downstream PV8 port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.42 | ColumnhwEndRspFrame | read-only | current | End RSP shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.43 | ColumnhwEndRspSlot | read-only | current | End RSP slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.44 | ColumnhwEndRspPort | read-only | current | End RSP port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.45 | ColumnhwIpSpcAttributeLocalIPAddr | read-write | current | Local IP address of the SPC. If the SPC's type is IPSPC, the local IP address must be configured. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.46 | ColumnhwIpSpcAttributeLocalPort | read-write | current | Local UDP port of the SPC. If the SPC's type is IPSPC, the local UDP port must be configured. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.47 | ColumnhwIpSpcAttributeRemoteIPAddr | read-write | current | Remote IP address of the SPC. If the SPC's type is IPSPC, the remote IP address mustd be configured. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.48 | ColumnhwIpSpcAttributeRemotePort | read-write | current | Remote UDP port of the SPC. If the SPC's type is IPSPC, the remote UDP port must be configured. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.49 | ColumnhwIpSpcAttributeVoiceCode | read-write | current | Voice codec type of the SPC. Options: 1. acG711Malaw(1) -G.711A 2. acG711Mulaw(2) -G.711U 3. acG723Low(3) -G.723low 4. acG723High(4) -G.723high 5. acG729(5) -G… |
| 1.3.6.1.4.1.2011.6.15.1.1.1.50 | ColumnhwIpSpcAttributeEce | read-write | current | The switch of EC. Options: 1. disable(1) -disable EC 2. enable(2) -enable EC 3. invalid(-1) -invalid value |
| 1.3.6.1.4.1.2011.6.15.1.1.1.51 | ColumnhwIpSpcAttributeSce | read-write | current | The switch of SC. Options: 1. disable(1) -disable SC 2. enable(2) -enable SC 3. invalid(-1) -invalid value |
| 1.3.6.1.4.1.2011.6.15.1.1.1.52 | ColumnhwIpSpcAttributeRtpInterval | read-write | current | RTP sampling time. Options: 1. five(1) -5 ms 2. ten(2) -10 ms 3. twenty(3) -20 ms 4. thirty(4) -30 ms 5. invalid(255) -invalid value Unit: millisecond |
| 1.3.6.1.4.1.2011.6.15.1.1.1.53 | ColumnhwIpSpcAttributePlc | read-write | current | The switch of PLC. Options: 1. enable(1) -enable PLC 2. disable(2) -disable PLC 3. invalid(255) -invalid value |
| 1.3.6.1.4.1.2011.6.15.1.1.1.54 | ColumnhwIpSpcAttributeRfc2198 | read-write | current | The switch of 2198. Options: 1. enable(1) -enable RFC2198 redundancy 2. disable(2) -disable RFC2198 redundancy 3. invalid(255) -invalid value |
| 1.3.6.1.4.1.2011.6.15.1.1.1.55 | ColumnhwIpSpcAttributeJbMode | read-write | current | Jitterbuffer mode. Options: 1. adapt(1) -adapt 2. fixed(2) -fixed 3. invalid(255) -invalid value |
| 1.3.6.1.4.1.2011.6.15.1.1.1.56 | ColumnhwIpSpcAttributeWorkMode | read-write | current | DSP work mode. Options: 1. voice(1) -voice 2. fax(2) -fax 3. modem(3) -modem 4. invalid(255) -invalid value |
| 1.3.6.1.4.1.2011.6.15.1.1.1.57 | ColumnhwIpSpcAttributeStreamMode | read-write | current | Connect mode. Options: 1. sendReceive(1) -send and receive 2. sendOnly(2) -send only 3. receiveOnly(3) -receive only 4. invalid(255) -invalid value |
| 1.3.6.1.4.1.2011.6.15.1.1.1.58 | ColumnhwRemotePortStepNum | read-create | current | The remote-port step. If the value is 65535, the ANSPC does not use the remote port step number attribute. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.59 | ColumnhwLinksetNo | read-create | current | IUA link set number. In the case of the U interface transparent, this parameter must be configured. If the value is -1, it indicates that the SPC does not use … |
| 1.3.6.1.4.1.2011.6.15.1.1.1.60 | ColumnhwInterfaceID | read-create | current | IUA interface ID. In the case of the U interface transparent, this parameter must be configured. If the value is -1, it indicates that the SPC does not use the… |
| 1.3.6.1.4.1.2011.6.15.1.1.1.61 | ColumnhwConfGroup | read-create | current | Conference Group ID. This leaf is not used on the OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.62 | ColumnhwB1DspInfo | read-only | current | Information of B1 DSP in conference service or BRA IP service. It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID. This le… |
| 1.3.6.1.4.1.2011.6.15.1.1.1.63 | ColumnhwB2DspInfo | read-only | current | Information of B2 DSP in BRA ip service. It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID This leaf is not used on OLT. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.64 | ColumnhwSignalType | read-write | current | Signal type of IP SPC. Options: 1. 1 - normal 2. 2 - 2833 This leaf is only used on the UA5000. |
| 1.3.6.1.4.1.2011.6.15.1.1.1.65 | ColumnhwSpcInitialRingType | read-write | current | IP SPC initial ring type. Enumeration type: 1-Null, 2-Normal ring (FSK) 1:4, 3-Special ring (FSK) 1:2, 4-Special ring (FSK) 0.4:0.2:0.4:4, 5-Special ring (FSK)… |
| 1.3.6.1.4.1.2011.6.15.1.1.1.66 | ColumnhwSpcCadenceRingType | read-write | current | IP SPC cadence ring type. Enumerated types: 1-Null, 2-Normal ring 1:4, 3-Special ring 1:2, 4-Special ring 0.4:0.2:0.4:4, 5-Long ring, 6-Special ring 1.2:2, 7-H… |
| 1.3.6.1.4.1.2011.6.15.1.1.1.67 | ColumnhwSpc2833Payload | read-write | current | IP SPC 2833 payload type. This leaf is only used on the UA5000. |
| 1.3.6.1.4.1.2011.6.15.1.3 | ScalarhwNextAllocSpcNo | read-only | current | Next valid allocation of SPC index Range: 0-2047 for MD products and 0-511 for MA products. |
| 1.3.6.1.4.1.2011.6.15.1.4 | TablehwSpcProtectGroupTable | not-accessible | current | You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable. The index of this table is hwSpcProtectGroupID. |
| 1.3.6.1.4.1.2011.6.15.1.4.1 | RowhwSpcProtectGroupEntry | not-accessible | current | You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable. The index of this entry is hwSpcProtectGroupID. |
| 1.3.6.1.4.1.2011.6.15.1.4.1.1 | ColumnhwSpcProtectGroupID | not-accessible | current | Index of the SPC E1 protect group. Range: 0-2 for UA products. |
| 1.3.6.1.4.1.2011.6.15.1.4.1.2 | ColumnhwSpcMainPortFrameID | read-write | current | Frame ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.4.1.3 | ColumnhwSpcMainPortSlotID | read-write | current | Slot ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.4.1.4 | ColumnhwSpcMainPortPortID | read-write | current | Port ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.4.1.5 | ColumnhwProtectGroupRowStatus | read-write | current | Row status. It supports only CreateAndGo(4) and Destroy(6). |
| 1.3.6.1.4.1.2011.6.15.1.5 | TablehwSpcProtectTable | not-accessible | current | You can add, delete, modify or query SPC protect link using hwSpcProtectTable. The index of this table is hwSpcProtectID. |
| 1.3.6.1.4.1.2011.6.15.1.5.1 | RowhwSpcProtectEntry | not-accessible | current | You can add, delete, modify or query SPC protect link using hwSpcProtectTable. The index of this entry is hwSpcProtectID. |
| 1.3.6.1.4.1.2011.6.15.1.5.1.1 | ColumnhwSpcProtectID | not-accessible | current | Index of the SPC E1 protect link. Range: 0-8 for UA products. |
| 1.3.6.1.4.1.2011.6.15.1.5.1.2 | ColumnhwSpcProtectGroupId | not-accessible | current | Index of the SPC E1 protect group. |
| 1.3.6.1.4.1.2011.6.15.1.5.1.3 | ColumnhwSpcProtectPortFrameID | read-write | current | Frame ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.5.1.4 | ColumnhwSpcProtectPortSlotID | read-write | current | Slot ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.5.1.5 | ColumnhwSpcProtectPortPortID | read-write | current | Port ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.5.1.6 | ColumnhwSpcProtectPriority | read-write | current | Priority of SPC E1 protect link. 1: cat1(1), 2: cat1(2), 3: cat1(3). |
| 1.3.6.1.4.1.2011.6.15.1.5.1.7 | ColumnhwSpcProtectUsedFlag | read-only | current | State of the SPC E1 protect link. |
| 1.3.6.1.4.1.2011.6.15.1.5.1.8 | ColumnhwProtectLinkRowStatus | read-write | current | Row status. It supports only CreateAndGo(4) and Destroy(6). |
| 1.3.6.1.4.1.2011.6.15.1.6 | TablehwSubRateSwitchTable | not-accessible | current | You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable. The index of this table is hwSubRateSwitchID. |
| 1.3.6.1.4.1.2011.6.15.1.6.1 | RowhwSubRateSwitchEntry | not-accessible | current | You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable. The index of this entry is hwSubRateSwitchID. |
| 1.3.6.1.4.1.2011.6.15.1.6.1.1 | ColumnhwSubRateSwitchID | not-accessible | current | Index of the sub-rate switch |
| 1.3.6.1.4.1.2011.6.15.1.6.1.2 | ColumnhwSubRateSwitchStartFrameID | read-create | current | Frame ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.6.1.3 | ColumnhwSubRateSwitchStartSlotID | read-create | current | Slot ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.6.1.4 | ColumnhwSubRateSwitchStartPortID | read-create | current | Port ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.6.1.5 | ColumnhwSubRateSwitchStartChannelID | read-create | current | Channel index of sub-rate switch start point |
| 1.3.6.1.4.1.2011.6.15.1.6.1.6 | ColumnhwSubRateSwitchStartSubChannelID | read-create | current | sub-rate channel index of sub-rate switch start point |
| 1.3.6.1.4.1.2011.6.15.1.6.1.7 | ColumnhwSubRateSwitchEndFrameID | read-create | current | Frame ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.6.1.8 | ColumnhwSubRateSwitchEndSlotID | read-create | current | Slot ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.6.1.9 | ColumnhwSubRateSwitchEndPortID | read-create | current | Port ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB. |
| 1.3.6.1.4.1.2011.6.15.1.6.1.10 | ColumnhwSubRateSwitchEndChannelID | read-create | current | Channel index of sub-rate switch end point. |
| 1.3.6.1.4.1.2011.6.15.1.6.1.11 | ColumnhwSubRateSwitchEndSubChannelID | read-create | current | sub-rate channel index of sub-rate switch end point. |
| 1.3.6.1.4.1.2011.6.15.1.6.1.12 | ColumnhwSubRateSwitchState | read-only | current | sub-rate switch state. Options: 1. fault(1) -fault 2. normal(2) -normal |
| 1.3.6.1.4.1.2011.6.15.1.6.1.13 | ColumnhwSubRateSwitchRowStatus | read-write | current | Row status. It supports only CreateAndGo(4) and Destroy(6). |
| 1.3.6.1.4.1.2011.6.15.1.7 | ScalarhwNextAllocSubRateSwitchID | read-only | current | Next valid allocation of SubRateSwitch index Range: 0-1023. |
| 1.3.6.1.4.1.2011.6.15.1.8 | ScalarhwIpSpcMinUdp | read-only | current | Start UDP port of IPSPC. Range: 0-65535. |
| 1.3.6.1.4.1.2011.6.15.1.9 | ScalarhwIpSpcMaxUdp | read-only | current | End UDP port of IPSPC. Range: 0-65535. |
| 1.3.6.1.4.1.2011.6.15.2 | NodehwSpcMibTrap | |||
| 1.3.6.1.4.1.2011.6.15.2.1 | NodehwSpcTrapOid | |||
| 1.3.6.1.4.1.2011.6.15.2.2 | NodehwSpcTrapsDefine | |||
| 1.3.6.1.4.1.2011.6.15.2.2.0 | NodehwSpcTraps | |||
| 1.3.6.1.4.1.2011.6.15.3 | NodehwSpcMibCompance | |||
| 1.3.6.1.4.1.2011.6.15.4 | NodehwIASSpcTrapsVbOids | |||
| 1.3.6.1.4.1.2011.6.15.4.1 | ScalarhwIASSpcBChn | accessible-for-notify | current | Indicates the B-channel. |
| 1.3.6.1.4.1.2011.6.15.4.2 | ScalarhwIASSpcDspFrame | accessible-for-notify | current | Indicate the shelf ID of a DSP resource board. |
| 1.3.6.1.4.1.2011.6.15.4.3 | ScalarhwIASSpcDspSlot | accessible-for-notify | current | Indicate the slot ID of a DSP resource board. |
| 1.3.6.1.4.1.2011.6.15.4.4 | ScalarhwIASSpcDspSub | accessible-for-notify | current | Indicate the DSP sub-board ID of a resource board. |
| 1.3.6.1.4.1.2011.6.15.4.5 | ScalarhwIASSpcDspChannel | accessible-for-notify | current | Indicate the DSP inner channel ID of a subboard. |
| 1.3.6.1.4.1.2011.6.15.4.6 | ScalarhwIASSpcDspLoopdelay | accessible-for-notify | current | Indicate the DSP loop delay. |
| 1.3.6.1.4.1.2011.6.15.4.7 | ScalarhwIASSpcDspFractionLost | accessible-for-notify | current | Indicate the DSP fractionLost. |
| 1.3.6.1.4.1.2011.6.15.4.8 | ScalarhwIASSpcDspJitter | accessible-for-notify | current | The DSP jitter. |
| 1.3.6.1.4.1.2011.6.15.4.9 | ScalarhwIASSpcOperateType | accessible-for-notify | current | Indicate the operate type on a SPC. Options: 1. add(0) -add spc link 2. delete(1) -delete spc link 3. modify(2) -modify spc link 4. release(3) -spc link end se… |
| 1.3.6.1.4.1.2011.6.15.5 | NodehwIASSpcTraps | |||
| 1.3.6.1.4.1.2011.6.15.5.1 | NodehwIASSpcCommonTraps | |||
| 1.3.6.1.4.1.2011.6.15.5.1.0 | NodehwIASSpcCommonTrapsPrefix | |||
| 1.3.6.1.4.1.2011.6.15.5.1.0.1 | NotificationhwIASSpcOperateTrap | current | This notification indicates that the operation on the SPC. | |
| 1.3.6.1.4.1.2011.6.15.5.2 | NodehwIASSpcAlarmTraps | |||
| 1.3.6.1.4.1.2011.6.15.5.2.0 | NodehwIASSpcAlarmTrapsPrefix | |||
| 1.3.6.1.4.1.2011.6.15.5.2.0.1 | NotificationhwIASSpcFaultTrap | current | This notification indicates that the SPC is faulty. | |
| 1.3.6.1.4.1.2011.6.15.5.2.0.2 | NotificationhwIASSpcRestoreTrap | current | This notification indicates that the SPC recovers from a fault. | |
| 1.3.6.1.4.1.2011.6.15.5.2.0.3 | NotificationhwIASSpcReleaseTrap | current | This notification indicates that the SPC is released. | |
| 1.3.6.1.4.1.2011.6.15.5.2.0.4 | NotificationhwIASSpcConnectTrap | current | This notification indicates that the SPC is connected again. | |
| 1.3.6.1.4.1.2011.6.15.5.2.0.5 | NotificationhwIASSpcQosExceedTrap | current | This notification indicates that the value of DSP QoS used by the SPC exceeds the threshold. | |
| 1.3.6.1.4.1.2011.6.15.5.2.0.6 | NotificationhwIASSpcQosRestoreTrap | current | This notification indicates that the value of DSP QoS used by the SPC is normal. |