MIB Viewer

HUAWEI-VO-ANALOG-IF-MIB

55 objects
No module-level DESCRIPTION found.
Imported Objects
HUAWEI-3COM-OID-MIBvoice
SNMPv2-SMIMODULE-IDENTITY OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011.5.25.1.3IdentityhwVoiceAnalogInterfaceMIB
1.3.6.1.4.1.2011.5.25.1.3.1NodehwVoAnalogIfCommonObjects
1.3.6.1.4.1.2011.5.25.1.3.1.1TablehwVoAnalogIfCommonConfigTablenot-accessiblecurrentThe voice analog interface common configuration table contains information about configuration parameters for analog voice interface.
1.3.6.1.4.1.2011.5.25.1.3.1.1.1RowhwVoAnalogIfCommonConfigEntrynot-accessiblecurrentAn entry in the voice analog interface common configuration table. The entry is automatically created when a analog voice interface hardware is found.
1.3.6.1.4.1.2011.5.25.1.3.1.1.1.1ColumnhwVoAnalogIfConfigPortNumberread-onlycurrentIndex of voice analog interface common config table. It identify the number of the voice port.
1.3.6.1.4.1.2011.5.25.1.3.1.1.1.2ColumnhwVoAnalogIfConfigPortTyperead-onlycurrentThis object expresses the type of the voice analog interfaces. fxs : the type of the voice port is FXS. fxo : the type of the voice port is FXO. em : the type …
1.3.6.1.4.1.2011.5.25.1.3.1.1.1.3ColumnhwVoAnaloglfConfigPortImpedanceread-onlycurrentThis object expresses the port impedance of voice analog interfaces. impedance600Real : 600 Ohms This impedance is primarily used by FXS. impedanceComplex : 20…
1.3.6.1.4.1.2011.5.25.1.3.1.1.1.4ColumnhwVoAnalogIfConfigInitialDigitTimeOutread-writecurrentThis object states the longgest time to wait the first input digit from caller side. The default value is 10 seconds.
1.3.6.1.4.1.2011.5.25.1.3.1.1.1.5ColumnhwVoAnalogIfConfigInterDigitTimeOutread-writecurrentThis object states the longest time to wait between two input digit from caller side. The default value is 10 seconds.
1.3.6.1.4.1.2011.5.25.1.3.1.1.1.6ColumnhwVoAnalogIfConfigCallDisconnectread-onlycurrentThis object states the time the system waits for the caller side to hang up after the connect is disable. The default value is 10 seconds.
1.3.6.1.4.1.2011.5.25.1.3.2NodehwVoAnalogIfFXSObjects
1.3.6.1.4.1.2011.5.25.1.3.2.1TablehwVoAnalogIfFXSConfigTablenot-accessiblecurrentThe voice analog interface fxs configuration table contains information about configuration parameters for analog fxs voice interface.
1.3.6.1.4.1.2011.5.25.1.3.2.1.1RowhwVoAnalogIfFXSConfigEntrynot-accessiblecurrentAn entry in the voice analog interface fxs configuration table. The entry is automatically created when a analog fxs voice interface hardware is found.
1.3.6.1.4.1.2011.5.25.1.3.2.1.1.1ColumnhwVoAnalogIfFXSConfigPortNumberread-onlycurrentIndex of voice analog interface fxs config table. It identify the number of the fxs voice port.
1.3.6.1.4.1.2011.5.25.1.3.2.1.1.2ColumnhwVoAnalogIfFXSConfigStartModeread-onlycurrentThis object expresses the signaling type of analog fxs interface. The default value is loopStart.
1.3.6.1.4.1.2011.5.25.1.3.2.3TablehwVoAnalogIfFXSTimerTablenot-accessiblecurrentThe voice analog interface fxs timer table contains information about timer parameters for analog fxs voice interface.
1.3.6.1.4.1.2011.5.25.1.3.2.3.1RowhwVoAnalogIfFXSTimerEntrynot-accessiblecurrentAn entry in the voice analog interface fxs configuration table. The entry is automatically created when a analog fxs voice interface hardware is found.
1.3.6.1.4.1.2011.5.25.1.3.2.3.1.1ColumnhwVoAnalogIfFXSTimerPortNumberread-onlycurrentIndex of voice analog interface fxs timer table. It identify the number of the fxs voice port.
1.3.6.1.4.1.2011.5.25.1.3.2.3.1.2ColumnhwVoAnalogIfFXSTimerDtmfread-onlycurrentThis object expresses outgoing dtmf digit duration of the analog fxs interface. The default value is 120 milliseconds
1.3.6.1.4.1.2011.5.25.1.3.2.3.1.3ColumnhwVoAnalogIfFXSTimerDtmfIntervalread-onlycurrentThis object expresses outgoing dtmf interval duration of the analog fxs interface. The default value is 120 milliseconds
1.3.6.1.4.1.2011.5.25.1.3.3NodehwVoAnalogIfFXOObjects
1.3.6.1.4.1.2011.5.25.1.3.3.1TablehwVoAnalogIfFXOConfigTablenot-accessiblecurrentThe voice analog interface fxo configuration table contains information about configuration parameters for analog fxo voice interface.
1.3.6.1.4.1.2011.5.25.1.3.3.1.1RowhwVoAnalogIfFXOConfigEntrynot-accessiblecurrentAn entry in the voice analog interface fxo configuration table. The entry is automatically created when a analog fxo voice interface hardware is found.
1.3.6.1.4.1.2011.5.25.1.3.3.1.1.1ColumnhwVoAnalogIfFXOConfigPortNumberread-onlycurrentIndex of voice analog interface fxo config table. It identify the number of the fxo voice port.
1.3.6.1.4.1.2011.5.25.1.3.3.1.1.2ColumnhwVoAnalogIfFXOConfigStartModeread-onlycurrentThis object expresses the signal type of analog fxo interface. The default value is fxoLoopStart.
1.3.6.1.4.1.2011.5.25.1.3.3.1.1.3ColumnhwVoAnalogIfFXOConfigAlertNumberread-onlycurrentThis object expresses the number of rings detected before loop being closed. The default value is 2.
1.3.6.1.4.1.2011.5.25.1.3.3.1.1.4ColumnhwVoAnalogIfFXOConfigArearead-writecurrentThis object expresses the busy tone of analog fxo interface. The default value is europe.
1.3.6.1.4.1.2011.5.25.1.3.3.1.1.5ColumnhwVoAnalogIfFXOPreDialDelayread-writecurrentThis object expresses the pre-dial delay of analog fxo interface. The default value is 1 seconds.
1.3.6.1.4.1.2011.5.25.1.3.3.1.1.6ColumnhwVoAnaloglfFXOConfigPortImpedanceread-writecurrentThis object expresses the port impedance of FXO interfaces.
1.3.6.1.4.1.2011.5.25.1.3.3.3TablehwVoAnalogIfFXOTimerTablenot-accessiblecurrentThe voice analog interface fxo timer table contains information about timer parameters for analog fxo voice interface.
1.3.6.1.4.1.2011.5.25.1.3.3.3.1RowhwVoAnalogIfFXOTimerEntrynot-accessiblecurrentAn entry in the voice analog interface fxo timer table. The entry is automatically created when a analog fxo voice interface hardware is found.
1.3.6.1.4.1.2011.5.25.1.3.3.3.1.1ColumnhwVoAnalogIfFXOTimerPortNumberread-onlycurrentIndex of voice analog interface fxo timer table. It identify the number of the fxo voice port.
1.3.6.1.4.1.2011.5.25.1.3.3.3.1.2ColumnhwVoAnalogIfFXOTimerDtmfread-writecurrentThis object expresses outgoing dtmf digit duration of the analog fxo interface. The default value is 120 milliseconds
1.3.6.1.4.1.2011.5.25.1.3.3.3.1.3ColumnhwVoAnalogIfFXOTimerDtmfIntervalread-writecurrentThis object expresses outgoing dtmf interval duration of the analog fxo interface. The default value is 120 milliseconds
1.3.6.1.4.1.2011.5.25.1.3.4NodehwVoAnalogIfEMObjects
1.3.6.1.4.1.2011.5.25.1.3.4.1TablehwVoAnalogIfEMConfigTablenot-accessiblecurrentThe voice analog interface e&m configuration table contains information about configuration parameters for analog e&m voice interface.
1.3.6.1.4.1.2011.5.25.1.3.4.1.1RowhwVoAnalogIfEMConfigEntrynot-accessiblecurrentAn entry in the voice analog interface e&m configuration table. The entry is automatically created when a analog e&m voice interface hardware is found.
1.3.6.1.4.1.2011.5.25.1.3.4.1.1.1ColumnhwVoAnalogIfEMConfigPortNumberread-onlycurrentIndex of voice analog interface e&m config table. It identify the number of the e&m voice port.
1.3.6.1.4.1.2011.5.25.1.3.4.1.1.2ColumnhwVoAnalogIfEMConfigSignalModeread-writecurrentThis object expresses the signal mode of the analog e&m interfaces. The default value is immediateDial.
1.3.6.1.4.1.2011.5.25.1.3.4.1.1.3ColumnhwVoAnalogIfEMConfigPhyParmread-writecurrentThis object expresses the operation of the analog e&m signal. The default value of this object is fourWiresOperation.
1.3.6.1.4.1.2011.5.25.1.3.4.1.1.4ColumnhwVoAnalogIfEMConfigPhyTyperead-writecurrentThis object expresses the e&m lead signaling type of the analog e&m interface. The default is type5.
1.3.6.1.4.1.2011.5.25.1.3.4.1.1.5ColumnhwVoAnalogIfEMConfigTimeoutRingingread-writecurrentThis object expresses the ring timeout of the analog e&m interface. The value of 65535 indicates the timer is approach infinity. The default value of this obje…
1.3.6.1.4.1.2011.5.25.1.3.4.1.1.6ColumnhwVoAnalogIfEMConfigTimeoutWaitDigitread-writecurrentThis object expresses the wait digit timeout of the analog e&m interface. The value of 65535 indicates the timer is approach infinity. The default value of thi…
1.3.6.1.4.1.2011.5.25.1.3.4.3TablehwVoAnalogIfEMTimerTablenot-accessiblecurrentThe voice analog interface e&m timer table contains information about timer parameters for analog e&m voice interface.
1.3.6.1.4.1.2011.5.25.1.3.4.3.1RowhwVoAnalogIfEMTimerEntrynot-accessiblecurrentAn entry in the voice analog interface e&m timer table. The entry is automatically created when a analog e&m voice interface hardware is found.
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.1ColumnhwVoAnalogIfEMTimerPortNumberread-onlycurrentIndex of voice analog interface e&m timer table. It identify the number of the e&m voice port.
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.2ColumnhwVoAnalogIfEMTimerDtmfread-writecurrentThis object expresses outgoing dtmf digit duration of the analog e&m interface. The default value is 120 milliseconds
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.3ColumnhwVoAnalogIfEMTimerDtmfIntervalread-writecurrentThis object expresses outgoing dtmf interval duration of the analog e&m interface. The default value is 120 milliseconds
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.4ColumnhwVoAnalogIfEMTimerCallIntervalread-writecurrentThis object expresses the dureation of call clearing. The default value is 200 milliseconds.
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.5ColumnhwVoAnalogIfEMTimerSendWinkread-writecurrentThis object expresses the max time between receiving seizure signal and sending wink signal. This object can olny be used when hwVoAnalogIfEMConfigSignalMode i…
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.6ColumnhwVoAnalogIfEMTimerWinkRisingread-writecurrentThis object expresses the max time between sending seizure signal and receiving wink signal. This object can only be used when hwVoAnalogIfEMConfigSignalMode i…
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.7ColumnhwVoAnalogIfEMTimerWinkHoldread-writecurrentThis object expresses the max duration for sending wink signal. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'winkStart'. The default va…
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.8ColumnhwVoAnalogIfEMTimerDialoutDelayread-writecurrentThis object expresses max time sending called digits. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'immediate'. The default value is 300…
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.9ColumnhwVoAnalogIfEMTimerRisingread-writecurrentThis object expresses the wait duration between receiveing seizure signal and sending delay signal. This object can only be used when hwVoAnalogIfEMConfigSigna…
1.3.6.1.4.1.2011.5.25.1.3.4.3.1.10ColumnhwVoAnalogIfEMTimerHoldread-writecurrentThis object expresses the max time sending delay signal. This object can only be used when hwVoAnalogIfEMConfigSignalMode is 'delayDial'. The default value is …