HW-IMAPV1NORTHBOUND-TRAP-MIB

66 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011Nodehuawei
1.3.6.1.4.1.2011.2Nodeproducts
1.3.6.1.4.1.2011.2.15NodehwNetManagement
1.3.6.1.4.1.2011.2.15.1NodehwNmAgent
1.3.6.1.4.1.2011.2.15.1.3NodehwNmFault
1.3.6.1.4.1.2011.2.15.1.3.5ScalarthirdNMSFaultFilterread-writemandatoryIP:Port:AlarmLevelFilter:AlarmCategoryFilter AlarmLevelFilter = xxxx (Critical, Major, Minor, Warning) (1 - filter, 0 - report) AlarmCategoryFilter = yyyyyy (E…
1.3.6.1.4.1.2011.2.15.1.3.6ScalarhwNmClearAlarmsread-writemandatoryThis provides the functionality of clearing alarms to third party NMS. The alarms can be cleared based on alarm serial number. Multiple serial numbers are sepa…
1.3.6.1.4.1.2011.2.15.1.3.7ScalarhwNmAcknowledgeAlarmsread-writemandatoryThis provides the functionality of acknowledging alarms to third party NMS. The alarms can be acknowledged based on alarm serial number. Multiple serial number…
1.3.6.1.4.1.2011.2.15.1.3.8ScalarhwNmUnAcknowledgeAlarmsread-writemandatoryThis provides the functionality of unacknowledging alarms to third party NMS. The alarms can be unacknowledged based on alarm serial number. Multiple serial nu…
1.3.6.1.4.1.2011.2.15.1.7NodehwNmNorthboundEvent
1.3.6.1.4.1.2011.2.15.1.7.1NodehwNmNorthboundEventInfo
1.3.6.1.4.1.2011.2.15.1.7.1.1NodehwNmNorthboundEventNotifyNotification for real-time alarm.
1.3.6.1.4.1.2011.2.15.1.7.1.1ScalarhwNmNorthboundNENameread-onlymandatoryThe name of network element,string (255). LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in respon…
1.3.6.1.4.1.2011.2.15.1.7.1.2ScalarhwNmNorthboundNETyperead-onlymandatoryDevice type of element,string(64). LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for …
1.3.6.1.4.1.2011.2.15.1.7.1.3NodehwNmNorthboundEventNotifyCriticalNotification for real-time alarm whose level is Critical.
1.3.6.1.4.1.2011.2.15.1.7.1.3ScalarhwNmNorthboundObjectInstanceread-onlymandatoryInstance of element,such as number of Rack, Frame, Slot, Subslot, Port and so on,string(255). LIMITATION: On this object should not be readed. If read operatio…
1.3.6.1.4.1.2011.2.15.1.7.1.4NodehwNmNorthboundEventNotifyMajorNotification for real-time alarm whose level is Major.
1.3.6.1.4.1.2011.2.15.1.7.1.4ScalarhwNmNorthboundEventTyperead-onlymandatoryType of Event,string(64). LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for get opera…
1.3.6.1.4.1.2011.2.15.1.7.1.5NodehwNmNorthboundEventNotifyMinorNotification for real-time alarm whose level is Minor.
1.3.6.1.4.1.2011.2.15.1.7.1.5ScalarhwNmNorthboundEventTimeread-onlymandatoryTime at which the alarm was generated,string(64). It can be of any of the following formats: 1. Local Time without timezone information - 'YYYY/MM/DD - hh:mm:s…
1.3.6.1.4.1.2011.2.15.1.7.1.6NodehwNmNorthboundEventNotifyWarningNotification for real-time alarm whose level is Warning.
1.3.6.1.4.1.2011.2.15.1.7.1.6ScalarhwNmNorthboundProbableCauseread-onlymandatoryProbable cause of the alarm, string(4096). LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in respo…
1.3.6.1.4.1.2011.2.15.1.7.1.7NodehwNmNorthboundEventNotifyIndefinitelyNotification for real-time alarm whose level is Indefinitely.
1.3.6.1.4.1.2011.2.15.1.7.1.7ScalarhwNmNorthboundSeverityread-onlymandatoryLevel of Alarm., string(64) It can be any of the following: Critical, Major, Minor, Warning, Indeterminate. LIMITATION: On this object should not be readed. If…
1.3.6.1.4.1.2011.2.15.1.7.1.8ScalarhwNmNorthboundEventDetailread-onlymandatoryAlarm ID and detail information, string(4096). LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in r…
1.3.6.1.4.1.2011.2.15.1.7.1.8NodehwNmNorthboundEventNotifyUnknownSeverityNotification for real-time alarm whose level is UnknownSeverity.
1.3.6.1.4.1.2011.2.15.1.7.1.9ScalarhwNmNorthboundAdditionalInforead-onlymandatoryAdditional information of device, such as Country, City and so on, string(255). LIMITATION: On this object should not be readed. If read operation is performed…
1.3.6.1.4.1.2011.2.15.1.7.1.10ScalarhwNmNorthboundFaultFlagread-onlymandatoryThe flag which specifies whether the alarm is an Event, Fault, Recovery, Acknowledge Unacknowledge or Change. LIMITATION: On this object should not be readed. …
1.3.6.1.4.1.2011.2.15.1.7.1.11ScalarhwNmNorthboundFaultFunctionread-onlymandatoryThe function type of the alarm.It can be one of these values:'Power','Environment','Signal','Relay','Hardware','Software','Run','Communication','Service','Proc…
1.3.6.1.4.1.2011.2.15.1.7.1.12ScalarhwNmNorthboundDeviceIPread-onlymandatoryIP address of the device. LIMITATION: On this object should not be readed. If read operation is performed 0.0.0.0 (Null) value will be send in response for get…
1.3.6.1.4.1.2011.2.15.1.7.1.13ScalarhwNmNorthboundSerialNoread-onlymandatoryThe serial number of alarm. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for get ope…
1.3.6.1.4.1.2011.2.15.1.7.1.14ScalarhwNmNorthboundProbableRepairread-onlymandatoryAlarm repair recommendations. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for get o…
1.3.6.1.4.1.2011.2.15.1.7.1.15ScalarhwNmNorthboundResourceIDsread-onlymandatoryThe ID of the resource. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for get operati…
1.3.6.1.4.1.2011.2.15.1.7.1.16ScalarhwNmNorthboundsAdditionalVB1read-onlymandatoryAdditional information of the alarm. These 8 fields are decided by configuration in snmpagent.xml. LIMITATION: On this object should not be readed. If read ope…
1.3.6.1.4.1.2011.2.15.1.7.1.17ScalarhwNmNorthboundsAdditionalVB2read-onlymandatoryAdditional information of the alarm. These 8 fields are decided by configuration in snmpagent.xml. LIMITATION: On this object should not be readed. If read ope…
1.3.6.1.4.1.2011.2.15.1.7.1.18ScalarhwNmNorthboundsAdditionalVB3read-onlymandatoryAdditional information of the alarm. These 8 fields are decided by configuration in snmpagent.xml. LIMITATION: On this object should not be readed. If read ope…
1.3.6.1.4.1.2011.2.15.1.7.1.19ScalarhwNmNorthboundsAdditionalVB4read-onlymandatoryAdditional information of the alarm. These 8 fields are decided by configuration in snmpagent.xml. LIMITATION: On this object should not be readed. If read ope…
1.3.6.1.4.1.2011.2.15.1.7.1.20ScalarhwNmNorthboundsAdditionalVB5read-onlymandatoryAdditional information of the alarm. These 8 fields are decided by configuration in snmpagent.xml. LIMITATION: On this object should not be readed. If read ope…
1.3.6.1.4.1.2011.2.15.1.7.1.21ScalarhwNmNorthboundsAdditionalVB6read-onlymandatoryAdditional information of the alarm. These 8 fields are decided by configuration in snmpagent.xml. LIMITATION: On this object should not be readed. If read ope…
1.3.6.1.4.1.2011.2.15.1.7.1.22ScalarhwNmNorthboundsAdditionalVB7read-onlymandatoryAdditional information of the alarm. These 8 fields are decided by configuration in snmpagent.xml. LIMITATION: On this object should not be readed. If read ope…
1.3.6.1.4.1.2011.2.15.1.7.1.23ScalarhwNmNorthboundsAdditionalVB8read-onlymandatoryAdditional information of the alarm. These 8 fields are decided by configuration in snmpagent.xml. LIMITATION: On this object should not be readed. If read ope…
1.3.6.1.4.1.2011.2.15.1.7.1.24ScalarhwNmNorthboundEventNameread-onlymandatoryThe name of event,string (4096). LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for ge…
1.3.6.1.4.1.2011.2.15.1.7.1.25ScalarhwNmNorthboundReasonIDread-onlymandatoryThe Reason ID of the alarm. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for get ope…
1.3.6.1.4.1.2011.2.15.1.7.1.26ScalarhwNmNorthboundFaultIDread-onlymandatoryThe Fault ID of the alarm. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for get oper…
1.3.6.1.4.1.2011.2.15.1.7.1.27ScalarhwNmNorthboundDeviceTyperead-onlymandatoryThe Device Type ID of the alarm. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for ge…
1.3.6.1.4.1.2011.2.15.1.7.1.28ScalarhwNmNorthboundTrailNameread-onlymandatoryTrailName effected by alarm. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for get op…
1.3.6.1.4.1.2011.2.15.1.7.1.29ScalarhwNmNorthboundRootAlarmread-onlymandatorySpecifies if the alarm is a root alarm 0 - Non-root alarm 1 - Root alarm LIMITATION: On this object should not be readed. If read operation is performed 0 (Nul…
1.3.6.1.4.1.2011.2.15.1.7.1.30ScalarhwNmNorthboundGroupIDread-onlymandatoryThe Group ID of the alarm. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for get oper…
1.3.6.1.4.1.2011.2.15.1.7.1.31ScalarhwNmNorthboundMaintainStatusread-onlymandatoryIndicates the engineering alarm status. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response…
1.3.6.1.4.1.2011.2.15.1.7.1.32ScalarhwNmNorthboundRootAlarmSerialNoread-onlymandatoryThe serial number of root alarm. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value will be send in response for ge…
1.3.6.1.4.1.2011.2.15.1.7.1.33ScalarhwNmNorthboundConfirmStatusread-onlymandatorySpecifies if the alarm is acknowledged. 1 - acknowledged 2 - unacknowledged LIMITATION: On this object should not be readed. If read operation is performed 0 (…
1.3.6.1.4.1.2011.2.15.1.7.1.34ScalarhwNmNorthboundRestoreStatusread-onlymandatorySpecifies if the alarm is cleared. 1 - cleared 2 - uncleared LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value wil…
1.3.6.1.4.1.2011.2.15.1.7.2NodehwNmNorthboundEventKeepAliveInfo
1.3.6.1.4.1.2011.2.15.1.7.2.1ScalarhwNmNorthboundKeepAliveread-onlymandatoryEMS sends the KeepAlive info (heartbeat) to the NMS/OSS regularly each period. it identifies that the OSS communicates properly with the EMS. LIMITATION: On th…
1.3.6.1.4.1.2011.2.15.1.7.2.2NodehwNmNorthboundEventKeepAliveNotification for keep alive traps.
1.3.6.1.4.1.2011.2.15.1.7.7NodehwNmNorthboundEventSynchronization
1.3.6.1.4.1.2011.2.15.1.7.7.1NodehwNmNorthboundEventSynchronizationStart
1.3.6.1.4.1.2011.2.15.1.7.7.1.9NodehwNmNorthboundEventSynchronizationStartNotifyNotification indicates the beginning of alarm synchronization.
1.3.6.1.4.1.2011.2.15.1.7.7.2NodehwNmNorthboundEventSynchronizationQueryResult
1.3.6.1.4.1.2011.2.15.1.7.7.2.10NodehwNmNorthboundEventSynchronizationQueryResultNotifyNotification carries the query result of alarm synchronization.
1.3.6.1.4.1.2011.2.15.1.7.7.3NodehwNmNorthboundEventSynchronizationEnd
1.3.6.1.4.1.2011.2.15.1.7.7.3.1ScalarhwNmNorthboundEventSynchronizationEndStatusread-onlymandatoryIt shows the result of alarm synchronization. 1 means the alarm synchronization successfully ended. 2 means the alarm synchronization is stopped by the NMS's c…
1.3.6.1.4.1.2011.2.15.1.7.7.3.2ScalarhwNmNorthboundEventSynchronizationEndStatusDetailread-onlymandatoryThe detail description of the alarm synchronization end status. LIMITATION: On this object should not be readed. If read operation is performed 0 (Null) value …
1.3.6.1.4.1.2011.2.15.1.7.7.3.11NodehwNmNorthboundEventSynchronizationEndNotifyNotification indicates the end of alarm synchronization.
1.3.6.1.4.1.2011.2.15.1.7.7.4ScalarhwNmNorthboundEventSynchronizationCommandStartread-writemandatoryThis node is to be set to start the alarm synchronization. The format to query alarms is:- IP:port:start time:end time Query time can be UTC time, Local time o…
1.3.6.1.4.1.2011.2.15.1.7.7.5ScalarhwNmNorthboundEventSynchronizationCommandStopread-writemandatoryThis node is to be set to stop the alarm synchronization. It should be set as NMS's IP:port,and the agent will stop alarm synchronization for the IP and port s…