IBM-SERVERAID-MIB
132 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Gauge |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-SMI-v1 | enterprises |
| SNMPv2-TC-v1 | DateAndTime TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2 | Nodeibm | |||
| 1.3.6.1.4.1.2.6 | NodeibmProd | |||
| 1.3.6.1.4.1.2.6.167 | NodeibmServeRaid | |||
| 1.3.6.1.4.1.2.6.167.2 | NodeibmServeRaidMIB | |||
| 1.3.6.1.4.1.2.6.167.2.0 | NodeibmServeRaidNotifications | |||
| 1.3.6.1.4.1.2.6.167.2.1 | NodeibmServeRaidMibObjects | |||
| 1.3.6.1.4.1.2.6.167.2.1.1 | NodeibmServeRaidAgentInfo | |||
| 1.3.6.1.4.1.2.6.167.2.1.1.1 | ScalaribmServeRaidAgentKeyIndex | read-only | mandatory | |
| 1.3.6.1.4.1.2.6.167.2.1.1.2 | ScalaribmServeRaidAgentId | read-only | mandatory | ServeRAID (sub-)agent ID string |
| 1.3.6.1.4.1.2.6.167.2.1.1.3 | ScalaribmServeRaidAgentCompany | read-only | mandatory | ServeRAID (sub-)agent company string |
| 1.3.6.1.4.1.2.6.167.2.1.1.4 | ScalaribmServeRaidAgentVersion | read-only | mandatory | ServeRAID (sub-)agent version string |
| 1.3.6.1.4.1.2.6.167.2.1.1.5 | ScalaribmServeRaidAgentBuildDate | read-only | mandatory | ServeRAID (sub-)agent build date and time |
| 1.3.6.1.4.1.2.6.167.2.1.1.6 | ScalaribmServeRaidAgentVersionMajor | read-only | mandatory | ServeRAID (sub-)agent major version number |
| 1.3.6.1.4.1.2.6.167.2.1.1.7 | ScalaribmServeRaidAgentVersionMinor | read-only | mandatory | ServeRAID (sub-)agent minor version number |
| 1.3.6.1.4.1.2.6.167.2.1.2 | NodeibmServeRaidInfo | |||
| 1.3.6.1.4.1.2.6.167.2.1.2.1 | TableibmServeRaidControllerTable | not-accessible | mandatory | ServeRAID Controller table |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1 | RowibmServeRaidControllerEntry | not-accessible | mandatory | ServeRAID Controller table entry |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.1 | ColumnibmServeRaidKeyIndex | not-accessible | mandatory | |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.2 | ColumnibmServeRaidControllerId | not-accessible | mandatory | ServeRAID Controller number (index) |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.3 | ColumnibmServeRaidModel | read-only | mandatory | Controller model/submodel |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.4 | ColumnibmServeRaidFirmwareVersion | read-only | mandatory | Firmware version |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.5 | ColumnibmServeRaidBiosVersion | read-only | mandatory | BIOS version |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.6 | ColumnibmServeRaidDefaultRebuildRate | read-only | mandatory | Default rebuild/check rate |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.7 | ColumnibmServeRaidNumChannels | read-only | mandatory | Number of channels currently in use |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.8 | ColumnibmServeRaidMaxChannels | read-only | mandatory | Maximum number of channels |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.9 | ColumnibmServeRaidNumLogicalDrives | read-only | mandatory | Current number of logical drives |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.10 | ColumnibmServeRaidMaxLogicalDrives | read-only | mandatory | Maximum logical drives |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.11 | ColumnibmServeRaidNumPhysicalDevices | read-only | mandatory | Current number of physical devices |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.12 | ColumnibmServeRaidMaxPhysicalDevices | read-only | mandatory | Maximum physical devices |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.13 | ColumnibmServeRaidStripeSize | read-only | mandatory | Stripe Size (in 1K byte chunks) |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.14 | ColumnibmServeRaidSlotNumber | read-only | mandatory | Slot number the controller is in |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.15 | ColumnibmServeRaidVendorName | read-only | mandatory | Name of the controller vendor |
| 1.3.6.1.4.1.2.6.167.2.1.2.1.1.16 | ColumnibmServeRaidGeneralStatus | read-only | mandatory | General controller status |
| 1.3.6.1.4.1.2.6.167.2.1.2.2 | TableibmServeRaidPhysDeviceTable | not-accessible | mandatory | Physical device info table |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1 | RowibmServeRaidPhysDeviceEntry | not-accessible | mandatory | Physical device info table entry |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1.1 | ColumnibmServeRaidPhysDeviceKeyIndex | not-accessible | mandatory | |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1.2 | ColumnibmServeRaidPhysDeviceChannelNr | not-accessible | mandatory | Channel number (index) |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1.3 | ColumnibmServeRaidPhysDeviceDevNr | not-accessible | mandatory | Physical device number (index). This corresponds to the SCSI ID. |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1.4 | ColumnibmServeRaidPhysDeviceModel | read-only | mandatory | Physical device model name |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1.5 | ColumnibmServeRaidPhysDeviceCapacity | read-only | mandatory | Disk capacity (MBytes) |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1.6 | ColumnibmServeRaidPhysDeviceStatus | read-only | mandatory | Disk status |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1.7 | ColumnibmServeRaidPhysDeviceDiskConfigured | read-only | mandatory | Indicates if device is a configured disk |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1.8 | ColumnibmServeRaidPhysDeviceScsiType | read-only | mandatory | SCSI device type |
| 1.3.6.1.4.1.2.6.167.2.1.2.2.1.9 | ColumnibmServeRaidPhysDevicePfaStatus | read-only | mandatory | Reports status of drive predictive failure analysis, drive should be replaced if failure-predicted. |
| 1.3.6.1.4.1.2.6.167.2.1.2.3 | TableibmServeRaidLogicalTable | not-accessible | mandatory | ServeRAID Logical drive info table |
| 1.3.6.1.4.1.2.6.167.2.1.2.3.1 | RowibmServeRaidLogicalEntry | not-accessible | mandatory | Logical drive info table entry |
| 1.3.6.1.4.1.2.6.167.2.1.2.3.1.1 | ColumnibmServeRaidLogicalKeyIndex | not-accessible | mandatory | |
| 1.3.6.1.4.1.2.6.167.2.1.2.3.1.2 | ColumnibmServeRaidLogicalDriveNum | not-accessible | mandatory | Logical drive number (index) |
| 1.3.6.1.4.1.2.6.167.2.1.2.3.1.3 | ColumnibmServeRaidLogicalStatus | read-only | mandatory | Logical drive status |
| 1.3.6.1.4.1.2.6.167.2.1.2.3.1.4 | ColumnibmServeRaidLogicalSize | read-only | mandatory | Size of logical drive (MBytes) |
| 1.3.6.1.4.1.2.6.167.2.1.2.3.1.5 | ColumnibmServeRaidLogicalRaidLevel | read-only | mandatory | Drive RAID level. |
| 1.3.6.1.4.1.2.6.167.2.1.2.3.1.6 | ColumnibmServeRaidLogicalWriteCacheMode | read-only | mandatory | Cache write back / write through |
| 1.3.6.1.4.1.2.6.167.2.1.3 | NodeibmServeRaidTrapInfo | |||
| 1.3.6.1.4.1.2.6.167.2.1.3.1 | ScalaribmServeRaidTrapController | not-accessible | mandatory | The controller number |
| 1.3.6.1.4.1.2.6.167.2.1.3.2 | ScalaribmServeRaidTrapLogicalDrive | not-accessible | mandatory | The logical drive number |
| 1.3.6.1.4.1.2.6.167.2.1.3.3 | ScalaribmServeRaidTrapChannel | not-accessible | mandatory | The SCSI Channel of the physical drive |
| 1.3.6.1.4.1.2.6.167.2.1.3.4 | ScalaribmServeRaidTrapScsiId | not-accessible | mandatory | The SCSI Target id of the physical drive |
| 1.3.6.1.4.1.2.6.167.2.1.3.5 | ScalaribmServeRaidTrapFan | not-accessible | mandatory | The fan number in the drive enclosure |
| 1.3.6.1.4.1.2.6.167.2.1.3.6 | ScalaribmServeRaidTrapPowerSupply | not-accessible | mandatory | The power supply in the drive enclosure |
| 1.3.6.1.4.1.2.6.167.2.1.3.7 | ScalaribmServeRaidTrapErrorCode | not-accessible | mandatory | The error code reported by the controller |
| 1.3.6.1.4.1.2.6.167.2.1.3.8 | ScalaribmServeRaidTrapServerName | not-accessible | mandatory | Server name this trap comes from |
| 1.3.6.1.4.1.2.6.167.2.1.3.9 | ScalaribmServeRaidTrapArray | not-accessible | mandatory | Alphanumeric digit that identifies the array |
| 1.3.6.1.4.1.2.6.167.2.1.3.10 | ScalaribmServeRaidTrapFru | not-accessible | mandatory | The fru number of the device |
| 1.3.6.1.4.1.2.6.167.2.2 | NodeibmServeRaidConformance | |||
| 1.3.6.1.4.1.2.6.167.2.2.1 | NodeibmServeRaidCompliances | |||
| 1.3.6.1.4.1.2.6.167.2.2.1.1 | NodeibmServeRaidCompliance | |||
| 1.3.6.1.4.1.2.6.167.2.2.2 | NodeibmServeRaidGroups | |||
| 1.3.6.1.4.1.2.6.167.2.2.2.1 | NodeibmServeRaidAgentGroup | |||
| 1.3.6.1.4.1.2.6.167.2.2.2.2 | NodeibmServeRaidControllerGroup | |||
| 1.3.6.1.4.1.2.6.167.2.2.2.3 | NodeibmServeRaidPhysicalGroup | |||
| 1.3.6.1.4.1.2.6.167.2.2.2.4 | NodeibmServeRaidLogicalGroup | |||
| 1.3.6.1.4.1.2.6.167.2.2.2.5 | NodeibmServeRaidTrapInfoGroup | |||
| 1.3.6.1.4.1.2.6.167.2.2.2.6 | NodeibmServeRaidNotificationsGroup | |||
| 1.3.6.1.4.1.2.6.167.2.201 | NodeibmServeRaidNoControllers | Informational: No controllers were found in this system. | ||
| 1.3.6.1.4.1.2.6.167.2.202 | NodeibmServeRaidControllerFail | Error: Commands not responding on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.203 | NodeibmServeRaidDeadBattery | Error: The battery-backup cache device on Controller %d needs a new battery. | ||
| 1.3.6.1.4.1.2.6.167.2.204 | NodeibmServeRaidDeadBatteryCache | Error: The battery-backup cache device on Controller %d is defective %d | ||
| 1.3.6.1.4.1.2.6.167.2.205 | NodeibmServeRaidPollingFail | Error: Background polling commands not responding on Controller %d %d | ||
| 1.3.6.1.4.1.2.6.167.2.206 | NodeibmServeRaidConfigFail | Error: Cannot read controller configuration. | ||
| 1.3.6.1.4.1.2.6.167.2.207 | NodeibmServeRaidControllerAdded | Informational: Controller %d has been added to the system. | ||
| 1.3.6.1.4.1.2.6.167.2.208 | NodeibmServeRaidControllerReplaced | Informational: Controller %d has been replaced in the system. | ||
| 1.3.6.1.4.1.2.6.167.2.209 | NodeibmServeRaidControllerFailover | Informational: Controller %d failover detected. Passive controller is now active. | ||
| 1.3.6.1.4.1.2.6.167.2.301 | NodeibmServeRaidLogicalDriveCritical | Warning: Logical Drive %d is Critical on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.302 | NodeibmServeRaidLogicalDriveBlocked | Error: Logical Drive %d is Blocked on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.303 | NodeibmServeRaidLogicalDriveOffLine | Error: Logical Drive %d is Offline on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.304 | NodeibmServeRaidRebuildDetected | Informational: Rebuilding Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.305 | NodeibmServeRaidRebuildComplete | Informational: Rebuild complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.306 | NodeibmServeRaidRebuildFail | Error: Rebuild failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.167.2.307 | NodeibmServeRaidSyncDetected | Informational: Synchronizing Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.308 | NodeibmServeRaidSyncComplete | Informational: Synchronization complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.309 | NodeibmServeRaidSyncFail | Error: Synchronization failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.167.2.310 | NodeibmServeRaidMigrationDetected | Informational: Migrating Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.311 | NodeibmServeRaidMigrationComplete | Informational: Migration complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.312 | NodeibmServeRaidMigrationFail | Error: Migration failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.167.2.313 | NodeibmServeRaidCompressionDetected | Informational: Compressing Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.314 | NodeibmServeRaidCompressionComplete | Informational: Compression complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.315 | NodeibmServeRaidcompressionFail | Error: Compression failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.167.2.316 | NodeibmServeRaidDecompressionDetected | Informational: Decompressing Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.317 | NodeibmServeRaidDecompressionComplete | Informational: Decompression complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.318 | NodeibmServeRaidDecompressionFail | Error: Decompression failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.167.2.319 | NodeibmServeRaidFlashCopyDetected | Informational: FlashCopying Logical Drive %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.320 | NodeibmServeRaidFlashCopyComplete | Informational: FlashCopy complete on Logical Drive %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.321 | NodeibmServeRaidFlashCopyFail | Error: FlashCopy failed on Logical Drive %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.167.2.322 | NodeibmServeRaidArrayRebuildDetected | Informational: Rebuilding Array %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.323 | NodeibmServeRaidArrayRebuildComplete | Informational: Rebuild complete on Array %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.324 | NodeibmServeRaidArrayRebuildFail | Error: Rebuild failed on Array %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.167.2.325 | NodeibmServeRaidArraySyncDetected | Informational: Synchronizing Array %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.326 | NodeibmServeRaidArraySyncComplete | Informational: Synchronization complete on Array %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.327 | NodeibmServeRaidArraySyncFail | Error: Synchronization failed on Array %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.167.2.328 | NodeibmServeRaidArrayFlashCopyDetected | Informational: FlashCopying Array %d on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.329 | NodeibmServeRaidArrayFlashCopyComplete | Informational: FlashCopy complete on Array %d of Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.330 | NodeibmServeRaidArrayFlashCopyFail | Error: FlashCopy failed on Array %d of Controller %d %d. | ||
| 1.3.6.1.4.1.2.6.167.2.331 | NodeibmServeRaidLogicalDriveUnblocked | Informational: Logical Drive %d is unblocked on Controller %d. | ||
| 1.3.6.1.4.1.2.6.167.2.401 | NodeibmServeRaidDefunctDrive | Error: Defunct drive on Controller %d, Channel %d, SCSI ID %d. | ||
| 1.3.6.1.4.1.2.6.167.2.402 | NodeibmServeRaidPfaDrive | Warning: PFA drive on Controller %d, Channel %d, SCSI ID %d. | ||
| 1.3.6.1.4.1.2.6.167.2.403 | NodeibmServeRaidDefunctReplaced | Informational: A drive is set to Hot-Spare on Controller %d, Channel %d, SCSI ID %d. | ||
| 1.3.6.1.4.1.2.6.167.2.404 | NodeibmServeRaidDefunctDriveFru | Error: Defunct drive (FRU Part # %d} on controller %d, channel %d, SCSI ID %d. | ||
| 1.3.6.1.4.1.2.6.167.2.405 | NodeibmServeRaidPfaDriveFru | Warning: PFA drive (FRU Part # %d) on Controller %d, Channel %d, SCSI ID %d. | ||
| 1.3.6.1.4.1.2.6.167.2.406 | NodeibmServeRaidUnsupportedDrive | Warning: Unsupported physical drive found on Controller %d, Channel %d, SCSI ID %d. | ||
| 1.3.6.1.4.1.2.6.167.2.501 | NodeibmServeRaidEnclosureOK | Informational: Enclosure device responding on Controller %d, Channel %d. | ||
| 1.3.6.1.4.1.2.6.167.2.502 | NodeibmServeRaidEnclosureFail | Error: Enclosure device not responding on Controller %d, Channel %d. | ||
| 1.3.6.1.4.1.2.6.167.2.503 | NodeibmServeRaidFanOk | Informational: Enclosure fan %d on Controller %d, Channel %d is now operational. | ||
| 1.3.6.1.4.1.2.6.167.2.504 | NodeibmServeRaidFanFail | Error: Enclosure fan %d on Controller %d, Channel %d is malfunctioning. | ||
| 1.3.6.1.4.1.2.6.167.2.505 | NodeibmServeRaidFanInstalled | Informational: Enclosure fan %d on Controller %d, Channel %d has been installed. | ||
| 1.3.6.1.4.1.2.6.167.2.506 | NodeibmServeRaidFanRemoved | Warning: Enclosure fan %d on Controller %d, Channel %d has been removed. | ||
| 1.3.6.1.4.1.2.6.167.2.507 | NodeibmServeRaidTempOk | Error: Enclosure temperature is in normal range on Controller %d, Channel %d. | ||
| 1.3.6.1.4.1.2.6.167.2.508 | NodeibmServeRaidTempFail | Error: Enclosure temperature is out of normal range on Controller %d, Channel %d. | ||
| 1.3.6.1.4.1.2.6.167.2.509 | NodeibmServeRaidPowerSupplyOk | Informational: Enclosure power supply %d on Controller %d, Channel %d is now operational. | ||
| 1.3.6.1.4.1.2.6.167.2.510 | NodeibmServeRaidPowerSupplyFail | Error: Enclosure power supply %d on Controller %d, Channel %d is malfunctioning. | ||
| 1.3.6.1.4.1.2.6.167.2.511 | NodeibmServeRaidPowerSupplyInstalled | Informational: Enclosure power supply %d on Controller %d, Channel %d has been installed. | ||
| 1.3.6.1.4.1.2.6.167.2.512 | NodeibmServeRaidPowerSupplyRemoved | Warning: Enclosure power supply %d on Controller %d, Channel %d has been removed. | ||
| 1.3.6.1.4.1.2.6.167.2.601 | NodeibmServeRaidTestTrap | Informational: This is a test trap. |