IBMIROCAUTH-MIB
45 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises |
| SNMPv2-SMI-v1 | Counter32 Gauge32 Integer32 IpAddress TimeTicks |
| SNMPv2-TC-v1 | AutonomousType DisplayString PhysAddress RowStatus TestAndIncr TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2 | Nodeibm | |||
| 1.3.6.1.4.1.2.6 | NodeibmProd | |||
| 1.3.6.1.4.1.2.6.72 | Nodeibm2210 | |||
| 1.3.6.1.4.1.2.6.119 | NodeibmIROC | |||
| 1.3.6.1.4.1.2.6.119.7 | NodeibmIROCconfig | |||
| 1.3.6.1.4.1.2.6.119.7.2 | NodeibmIROCconfigAuth | |||
| 1.3.6.1.4.1.2.6.119.7.2.0 | NodeibmAuthTraps | |||
| 1.3.6.1.4.1.2.6.119.7.2.1 | NodeibmAuthMIB | |||
| 1.3.6.1.4.1.2.6.119.7.2.1.1 | NodeibmAuthGeneral | |||
| 1.3.6.1.4.1.2.6.119.7.2.1.2 | TableauthUserProfileTable | not-accessible | mandatory | Table of named profiles. Used to collect information about tunnel profiles and user, e.g., PPP, related information. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1 | RowauthUserProfileEntry | not-accessible | mandatory | Each entry is a separate profile with associated attributes. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.1 | ColumnauthUserProfileName | not-accessible | mandatory | For ppp user, it is the name of the user. For tunnel connection definition, it is the host name of the remote tunnel end point. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.2 | ColumnauthUserProfileRowDefinition | read-write | mandatory | The status of the row. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.3 | ColumnauthUserProfilePassword | read-write | mandatory | The password for this user. It is used for PPP and SNMP users but not tunnel profiles. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.4 | ColumnauthUserProfileType | read-write | mandatory | The profile type. '80'H represents login. '40'H represents tunnel, and '20'H represents ppp, '10'H represents snmp. It is implementation choice to restrict to … |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.5 | ColumnauthUserProfileMaxConnectTime | read-write | mandatory | The max connection allowed per connection. A value of zero is using the interface default, and negative one (-1) indicates no limits. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.6 | ColumnauthUserProfileCallbackType | read-write | mandatory | The type of callback. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.7 | ColumnauthUserProfileCallbackNum | read-write | mandatory | The dial back phone number when callback type is required. An octet string of length zero indicates the dial back phone number is not set. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.8 | ColumnauthUserProfileDialout | read-write | mandatory | A user on the network may be requesting permission to use dialout function. This flag attached to the user profile determines whether the user is able to dialo… |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.9 | ColumnauthUserProfileEncryptionKey | read-write | mandatory | The encryption key. An octet string of length zero indicates the encryption key is not set. The key is used when ECP is negotiated for this user. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.10 | ColumnauthUserProfileStatus | read-write | mandatory | The status of the user profile entry. By setting the value to 'enabled' from a non-enabled status will reset the following statistics: authUserProfileGLoginsAt… |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.11 | ColumnauthUserProfileExpirationDate | read-write | mandatory | The date and time when the password will be expired. That is, the user will no longer be allowed to dial in after this time. A value of zero length indicates n… |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.12 | ColumnauthUserProfileGLoginAllowed | read-write | mandatory | Number of grace logins is allowed after expiration Some local maximum may apply. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.13 | ColumnauthUserProfileGLoginsAttempts | read-only | mandatory | Number of grace login attempted is attempted after the expiration of this user profile. Some local maximum may apply. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.14 | ColumnauthUserProfileLoginAttempts | read-only | mandatory | Total number of login attempted, sucessfully or not. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.15 | ColumnauthUserProfileLoginFails | read-only | mandatory | Total number of login failed. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.16 | ColumnauthUserProfileLoginLock | read-only | mandatory | Number of consecutive failed logins attempted. The number is reset to zero after a successful login. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.17 | ColumnauthUserProfileIpType | read-write | mandatory | The Ip network type of Dials. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.18 | ColumnauthUserProfileIpAddr | read-write | mandatory | IP address for this user. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.19 | ColumnauthUserProfileIpMask | read-write | mandatory | IP mask for this user. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.20 | ColumnauthUserProfileHostName | read-write | mandatory | The host name for this user. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.21 | ColumnauthUserProfileSharedSecurity | read-write | mandatory | The shared security between two L2TP Peers. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.22 | ColumnauthUserProfileTunneled | read-write | mandatory | The value of enabled means this PPP user profile is a tunneled user. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.23 | ColumnauthUserProfileTunnelType | read-write | mandatory | Tunneling Protocol. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.24 | ColumnauthUserProfileTunnelMediumType | read-write | mandatory | Tunneling Medium. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.25 | ColumnauthUserProfileTunnelServer | read-write | mandatory | Tunnel-Server endpoint address. For IP protocol, it is the server IP address in dotted notation. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.26 | ColumnauthUserProfileVcEnabled | read-write | mandatory | The value of enabled means this PPP user profile is a virtual connection user. |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.27 | ColumnauthUserProfileVcMaxSuspendTime | read-write | mandatory | The maximum amount of time (in hours) that the device will allow a virtual connection in suspend mode. After that, the device will remove the all states of the… |
| 1.3.6.1.4.1.2.6.119.7.2.1.2.1.28 | ColumnauthUserProfileVcIdleTime | read-write | mandatory | The device will instruct the dial-in station to suspend the real connection after the inactivity for this amount of time. A value of -1 means use the box defau… |
| 1.3.6.1.4.1.2.6.119.7.2.2 | NodeibmAuthDomains | |||
| 1.3.6.1.4.1.2.6.119.7.2.3 | NodeibmAuthConformance | |||
| 1.3.6.1.4.1.2.6.119.7.2.3.1 | NodeauthCompliances | |||
| 1.3.6.1.4.1.2.6.119.7.2.3.1.1 | NodeauthUserProfileCompliance | |||
| 1.3.6.1.4.1.2.6.119.7.2.3.2 | NodeauthGroups | |||
| 1.3.6.1.4.1.2.6.119.7.2.3.2.1 | NodeauthUserProfileGroup |