MIB Viewer

ICF-VG-RPTR

88 objects
This MIB module contains objects for managing HP AdvanceStack 100VG-AnyLAN repeaters. It is expected that this module will be superceded by a standard 802.12 Repeater MIB.
Imported Objects
HP-ICF-OIDhpicfObjectModules icfVgRepeater
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMICounter32 Counter64 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString MacAddress TimeStamp TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.11.2.14.8.1.1NodeicfVgBasic
1.3.6.1.4.1.11.2.14.8.1.1.1NodeicfVgBasicRptr
1.3.6.1.4.1.11.2.14.8.1.1.1.1ScalaricfVgMACAddressread-onlycurrentThe MAC address used by the repeater when it initiates training on the uplink port. Repeaters are allowed to train with an assigned MAC address or a null (all …
1.3.6.1.4.1.11.2.14.8.1.1.1.2ScalaricfVgCurrentFramingTyperead-onlycurrentThe type of framing (802.3 or 802.5) currently in use by the repeater.
1.3.6.1.4.1.11.2.14.8.1.1.1.3ScalaricfVgDesiredFramingTyperead-writecurrentThe type of framing which will be used by the repeater after the next time it is reset. The value of this object should be preserved across repeater resets and…
1.3.6.1.4.1.11.2.14.8.1.1.1.4ScalaricfVgFramingCapabilityread-onlycurrentThe type of framing this repeater is capable of supporting.
1.3.6.1.4.1.11.2.14.8.1.1.1.5ScalaricfVgTrainingVersionread-onlycurrentThe highest version bits (vvv bits) supported by the repeater during training.
1.3.6.1.4.1.11.2.14.8.1.1.1.6ScalaricfVgRepeaterGroupCapacityread-onlycurrentThe icfVgGroupCapacity is the number of groups that can be contained within the repeater. Within each managed repeater, the groups are uniquely numbered in the…
1.3.6.1.4.1.11.2.14.8.1.1.1.7ScalaricfVgRepeaterHealthStateread-onlycurrentThe icfVgRepeaterHealthState object indicates the operational state of the repeater. The icfVgRepeaterHealthText may be consulted for more specific information…
1.3.6.1.4.1.11.2.14.8.1.1.1.8ScalaricfVgRepeaterHealthTextread-onlycurrentThe health text object is a text string that provides information relevant to the operational state of the repeater. Agents may use this string to provide deta…
1.3.6.1.4.1.11.2.14.8.1.1.1.9ScalaricfVgRepeaterResetread-writecurrentSetting this object to reset(2) causes the repeater to transition to its initial state as specified in clause 12 [IEEE Draft Std 802.12]. Setting this object t…
1.3.6.1.4.1.11.2.14.8.1.1.1.10ScalaricfVgRepeaterNonDisruptTestread-writecurrentSetting this object to selfTest(2) causes the repeater to perform an agent-specific, non-disruptive self-test that has the following characteristics: a) The na…
1.3.6.1.4.1.11.2.14.8.1.1.2NodeicfVgBasicGroup
1.3.6.1.4.1.11.2.14.8.1.1.2.1TableicfVgBasicGroupTablenot-accessiblecurrentA table containing information about groups of ports.
1.3.6.1.4.1.11.2.14.8.1.1.2.1.1RowicfVgBasicGroupEntrynot-accessiblecurrentAn entry in the icfVgBasicGroupTable, containing information about a single group of ports.
1.3.6.1.4.1.11.2.14.8.1.1.2.1.1.1ColumnicfVgGroupIndexnot-accessiblecurrentThis object identifies the group within the repeater for which this entry contains information. This value is never greater than icfVgRepeaterGroupCapacity.
1.3.6.1.4.1.11.2.14.8.1.1.2.1.1.2ColumnicfVgGroupDescrread-onlycurrentA textual description of the group. This value should include the full name and version identification of the group's hardware type and indicate how the group …
1.3.6.1.4.1.11.2.14.8.1.1.2.1.1.3ColumnicfVgGroupObjectIDread-onlycurrentThe vendor's authoritative identification of the group. This value may be allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides a straight-fo…
1.3.6.1.4.1.11.2.14.8.1.1.2.1.1.4ColumnicfVgGroupOperStatusread-onlycurrentAn object that indicates the operational status of the group. A status of notPresent(4) indicates that the group is temporarily or permanently physically and/o…
1.3.6.1.4.1.11.2.14.8.1.1.2.1.1.5ColumnicfVgGroupLastOperStatusChangeread-onlycurrentAn object that contains the value of sysUpTime at the time that the value of the icfVgGroupOperStatus object for this group last changed. A value of zero indic…
1.3.6.1.4.1.11.2.14.8.1.1.2.1.1.6ColumnicfVgGroupPortCapacityread-onlycurrentThe icfVgGroupPortCapacity is the number of ports that can be contained within the group. Valid range is 1-1024. Within each group, the ports are uniquely numb…
1.3.6.1.4.1.11.2.14.8.1.1.2.1.1.7ColumnicfVgGroupCablesBundledread-writecurrentThis configuration flag is used to select either bundled or unbundled cabling. When this flag is 'someCablesBundled(1)' and the port is not promiscuous or casc…
1.3.6.1.4.1.11.2.14.8.1.1.3NodeicfVgBasicPort
1.3.6.1.4.1.11.2.14.8.1.1.3.1TableicfVgBasicPortTablenot-accessiblecurrentA table containing information about ports.
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1RowicfVgBasicPortEntrynot-accessiblecurrentAn entry in the icfVgBasicPortTable, containing information about a single port.
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.1ColumnicfVgPortGroupIndexnot-accessiblecurrentThis object identifies the group containing the port for which this entry contains information.
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.2ColumnicfVgPortIndexnot-accessiblecurrentThis object identifies the port within the group for which this entry contains information. This value can never be greater than icfVgGroupPortCapacity for the…
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.3ColumnicfVgPortTyperead-onlycurrentDescribes the type of port. One of the following: cascadeExternal - Port is an uplink with physical connections which are externally visible cascadeInternal - …
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.4ColumnicfVgPortAdminStatusread-writecurrentPort enable/disable function. Enabling a disabled port will cause training to be initiated. Setting this object to disabled(2) disables the port. A disabled po…
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.5ColumnicfVgPortStatusread-onlycurrentCurrent status for the port as specified by the PORT_META_STATE in the port process module of clause 12 [IEEE Draft Std 802.12]. During initialization or any l…
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.6ColumnicfVgPortSupportedPromiscModeread-onlycurrentThis object describes whether the port hardware is capable of supporting promiscuous mode, single address mode (i.e., repeater filters unicasts not addressed t…
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.7ColumnicfVgPortSupportedCascadeModeread-onlycurrentThis object describes whether the port hardware is capable of supporting cascaded repeaters, end nodes, or both. A port for which icfVgPortType is equal to 'ca…
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.8ColumnicfVgPortAllowedTrainTyperead-writecurrentThis security object is set by the network manager to configure what type of device is permitted to connect to the port. One of the following values: allowEndN…
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.9ColumnicfVgPortLastTrainConfigread-onlycurrentThis 16 bit field contains the most recent training configuration in an error-free training frame sent by the end node connected to the port. For cascade ports…
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.10ColumnicfVgPortTrainingResultread-onlycurrentThis 18 bit field is used to indicate the result of training. It contains two bits which indicate if error-free training frames have been received, and it also…
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.11ColumnicfVgPortPriorityEnableread-writecurrentA configuration flag used to determine whether the repeater will service high priority requests received on the port as high priority or normal priority. When …
1.3.6.1.4.1.11.2.14.8.1.1.3.1.1.12ColumnicfVgPortMediaTyperead-onlycurrentThe type of physical media in use. One of the following values: other undefined unknown true state not known pmdMissing PMD device not attached utp4 4-pair uns…
1.3.6.1.4.1.11.2.14.8.1.2NodeicfVgMonitor
1.3.6.1.4.1.11.2.14.8.1.2.1NodeicfVgMonRptr
1.3.6.1.4.1.11.2.14.8.1.2.2NodeicfVgMonGroup
1.3.6.1.4.1.11.2.14.8.1.2.3NodeicfVgMonPort
1.3.6.1.4.1.11.2.14.8.1.2.3.1TableicfVgMonPortTablenot-accessiblecurrentA table of performance and error statistics for the ports.
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1RowicfVgMonPortEntrynot-accessiblecurrentAn entry in the icfVgMonPortTable, containing performance and error statistics for a single port.
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.1ColumnicfVgPortReadableFramesread-onlycurrentThis object is the number of good frames of valid frame length that have been received on this port. This counter is incremented by one for each frame received…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.2ColumnicfVgPortReadableOctetsread-onlycurrentThis object is a count of the number of octets contained in good frames that have been received on this port. This counter is incremented by OctetCount for eac…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.3ColumnicfVgPortUnreadableOctetsread-onlycurrentThis object is a count of the number of octets contained in invalid frames that have been received on this port. This counter is incremented by OctetCount for …
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.4ColumnicfVgPortHighPriorityFramesread-onlycurrentThis object is a count of high priority frames that have been received on this port. This counter is incremented by one for each high priority frame received o…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.5ColumnicfVgPortHighPriorityOctetsread-onlycurrentThis object is a count of the number of octets contained in high priority frames that have been received on this port. This counter is incremented by OctetCoun…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.6ColumnicfVgPortBroadcastFramesread-onlycurrentThis object is a count of broadcast packets that have been received on this port. This counter is incremented by one for each readable frame received on this p…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.7ColumnicfVgPortMulticastFramesread-onlycurrentThis object is a count of multicast packets that have been received on this port. This counter is incremented by one for each readable frame received on this p…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.8ColumnicfVgPortIPMFramesread-onlycurrentThis object is a count of the number of frames that have been received on this port with an invalid packet marker and no PMI errors. A repeater will write an i…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.9ColumnicfVgPortDataErrorFramesread-onlycurrentThis object is a count of errored frames received on this port. This counter is incremented by one for each frame received on this port with any of the followi…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.10ColumnicfVgPortPriorityPromotionsread-onlycurrentThis counter is incremented by one each time the priority promotion timer has expired on this port and a normal priority frame was priority promoted.
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.11ColumnicfVgPortHCReadableOctetsread-onlycurrentThis object is a count of the number of octets contained in good frames that have been received on this port. This counter is incremented by OctetCount for eac…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.12ColumnicfVgPortHCUnreadableOctetsread-onlycurrentThis object is a count of the number of octets contained in invalid frames that have been received on this port. This counter is incremented by OctetCount for …
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.13ColumnicfVgPortHCHighPriorityOctetsread-onlycurrentThis object is a count of the number of octets contained in high priority frames that have been received on this port. This counter is incremented by OctetCoun…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.14ColumnicfVgPortHCNormPriorityOctetsread-onlycurrentThis object is a count of the number of octets contained in normal priority frames that have been received on this port. This counter is incremented by OctetCo…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.15ColumnicfVgPortNormPriorityFramesread-onlycurrentThis object is a count of normal priority frames that have been received on this port. This counter is incremented by one for each normal priority frame receiv…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.16ColumnicfVgPortNormPriorityOctetsread-onlycurrentThis object is a count of the number of octets contained in normal priority frames that have been received on this port. This counter is incremented by OctetCo…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.17ColumnicfVgPortNullAddressedFramesread-onlycurrentThis object is a count of null addressed packets that have been received on this port. This counter is incremented by one for each frame received on this port …
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.18ColumnicfVgPortOversizeFramesread-onlycurrentThis object is a count of oversize frames received on this port. This counter is incremented by one for each frame received on this port whose OctetCount is la…
1.3.6.1.4.1.11.2.14.8.1.2.3.1.1.19ColumnicfVgPortTransitionToTrainingsread-onlycurrentThis counter is incremented by one each time the icfVgPortStatus object for this port transitions into the 'training' state.
1.3.6.1.4.1.11.2.14.8.1.3NodeicfVgAddrTrack
1.3.6.1.4.1.11.2.14.8.1.3.1NodeicfVgAddrTrackRptr
1.3.6.1.4.1.11.2.14.8.1.3.2NodeicfVgAddrTrackGroup
1.3.6.1.4.1.11.2.14.8.1.3.3NodeicfVgAddrTrackPort
1.3.6.1.4.1.11.2.14.8.1.3.3.1TableicfVgAddrTrackTablenot-accessiblecurrentTable of address mapping information about the ports.
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1RowicfVgAddrTrackEntrynot-accessiblecurrentAn entry in the table, containing address mapping information about a single port.
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.1ColumnicfVgAddrLastTrainedAddressread-onlycurrentThis object is the MAC address of the last station which succeeded in training on this port. A cascaded repeater may train using the null address. If no statio…
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.2ColumnicfVgAddrTrainedAddrChangesread-onlycurrentThis counter is incremented by one for each time that the icfVgAddrLastTrainedAddress object for this port has changed.
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.3ColumnicfVgRptrDetectedDupAddressread-onlycurrentThis object is used to indicate that the repeater detected an error-free training frame on this port with a source MAC address which matches the value of icfVg…
1.3.6.1.4.1.11.2.14.8.1.3.3.1.1.4ColumnicfVgMgrDetectedDupAddressread-writecurrentThis object can be set by a management station when it detects that there is a duplicate MAC address. This object is OR'd with icfVgRptrDetectedDupAddress to f…
1.3.6.1.4.1.11.2.14.8.1.4NodeicfVgRptrTraps
1.3.6.1.4.1.11.2.14.8.1.4.0NodeicfVgRptrTrapsPrefix
1.3.6.1.4.1.11.2.14.8.1.4.0.1NotificationicfVgRptrHealthcurrentA icfVgRptrHealth trap conveys information related to the operational state of the repeater. This trap is sent either when the value of icfVgRepeaterHealthStat…
1.3.6.1.4.1.11.2.14.8.1.4.0.3NotificationicfVgRptrResetEventcurrentAn icfVgRptrResetEvent trap conveys information related to the operational state of the repeater. This trap is sent on completion of a repeater reset action. A…
1.3.6.1.4.1.11.2.14.10.2.10IdentityicfVgRepeaterMibinfoThis MIB module contains objects for managing HP AdvanceStack 100VG-AnyLAN repeaters. It is expected that this module will be superceded by a standard 802.12 R…
1.3.6.1.4.1.11.2.14.10.2.10.1NodeicfVgRepeaterConformance
1.3.6.1.4.1.11.2.14.10.2.10.1.1NodeicfVgRepeaterCompliances
1.3.6.1.4.1.11.2.14.10.2.10.1.1.1ComplianceicfVgRptrPreStdComplianceobsolete********* THIS COMPLIANCE IS OBSOLETE ********* The compliance statement for pre-standard 802.12 repeater management.
1.3.6.1.4.1.11.2.14.10.2.10.1.1.2ComplianceicfVgRptrCompliancecurrentThe compliance statement for 802.12 repeater management.
1.3.6.1.4.1.11.2.14.10.2.10.1.2NodeicfVgRepeaterGroups
1.3.6.1.4.1.11.2.14.10.2.10.1.2.1GroupicfVgRptrBasicGroupcurrentA collection of objects for managing the status and configuration of IEEE 802.12 repeaters.
1.3.6.1.4.1.11.2.14.10.2.10.1.2.2GroupicfVgRptrPreStdMonitorGroupobsolete********* THIS GROUP IS OBSOLETE ********* A collection of objects for providing statistics for pre-standard IEEE 802.12 repeaters.
1.3.6.1.4.1.11.2.14.10.2.10.1.2.3GroupicfVgRptrPreStdAddrTrackGroupobsolete********* THIS GROUP IS OBSOLETE ********* A collection of objects for tracking addresses on pre-standard IEEE 802.12 repeaters.
1.3.6.1.4.1.11.2.14.10.2.10.1.2.4GroupicfVgRptrMonitorGroupcurrentA collection of objects for providing statistics for IEEE 802.12 repeaters.
1.3.6.1.4.1.11.2.14.10.2.10.1.2.5GroupicfVgRptrAddrTrackGroupcurrentA collection of objects for tracking addresses on IEEE 802.12 repeaters.
1.3.6.1.4.1.11.2.14.10.2.10.1.2.6GroupicfVgRptrNotificationsGroupcurrentA collection of notifications used to indicate 802.12 repeater general status changes.