MIB Viewer

ICT-MODULAR-POWER-MIB

47 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises IpAddress
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.39145NodeictPower
1.3.6.1.4.1.39145.13NodepowerSystem
1.3.6.1.4.1.39145.13.1ScalardeviceModelread-onlymandatoryModel Number
1.3.6.1.4.1.39145.13.2ScalardeviceNameread-onlymandatoryDevice Name
1.3.6.1.4.1.39145.13.3ScalardeviceHardwareread-onlymandatoryHardware Version
1.3.6.1.4.1.39145.13.4ScalardeviceFirmwareread-onlymandatoryFirmware Version
1.3.6.1.4.1.39145.13.5ScalardeviceMacAddressread-onlymandatoryMAC Address
1.3.6.1.4.1.39145.13.6ScalarinputVoltageread-onlymandatoryInput Voltage (VAC)
1.3.6.1.4.1.39145.13.7ScalaroutputVoltageread-onlymandatoryOutput Voltage (VDC)
1.3.6.1.4.1.39145.13.8ScalaroutputCurrentread-onlymandatoryTotal System Current (Amps)
1.3.6.1.4.1.39145.13.9ScalaroutputEnableread-writemandatoryOutput Enable Status (a value of '1' indicates Output is Enabled, and a value of '2' indicates Output is Disabled. Output cannot be disabled during an AC Failu…
1.3.6.1.4.1.39145.13.10TablemoduleTablenot-accessiblemandatoryModule Table
1.3.6.1.4.1.39145.13.10.1RowmoduleEntrynot-accessiblemandatory
1.3.6.1.4.1.39145.13.10.1.1ColumnmoduleNumberread-onlymandatoryModule Number
1.3.6.1.4.1.39145.13.10.1.2ColumnmoduleStatusread-onlymandatoryModule Status
1.3.6.1.4.1.39145.13.10.1.3ColumnmoduleTyperead-onlymandatoryModule Type ('1' indicates Module is NOT INSTALLED,'2' indicates POWER Module,'3' indicates BATTERY Module,'4' indicates DISTRIBUTION Module, and '5' indicates…
1.3.6.1.4.1.39145.13.10.1.4ColumnmoduleVoltageread-onlymandatoryModule Voltage (VDC)
1.3.6.1.4.1.39145.13.10.1.5ColumnmoduleCurrentAread-onlymandatoryChannel 1 Current (Amps)
1.3.6.1.4.1.39145.13.10.1.6ColumnmoduleCurrentBread-onlymandatoryChannel 2 Current (Amps)
1.3.6.1.4.1.39145.13.10.1.7ColumnmoduleCurrentCread-onlymandatoryChannel 3 Current (Amps)
1.3.6.1.4.1.39145.13.10.1.8ColumnmoduleCurrentDread-onlymandatoryChannel 4 Current (Amps)
1.3.6.1.4.1.39145.13.10.1.9ColumnmoduleControlAread-writemandatoryChannel 1 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)
1.3.6.1.4.1.39145.13.10.1.10ColumnmoduleControlBread-writemandatoryChannel 2 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)
1.3.6.1.4.1.39145.13.10.1.11ColumnmoduleControlCread-writemandatoryChannel 3 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)
1.3.6.1.4.1.39145.13.10.1.12ColumnmoduleControlDread-writemandatoryChannel 4 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled)
1.3.6.1.4.1.39145.13.11TablealarmTablenot-accessiblemandatoryAlarm Input Table
1.3.6.1.4.1.39145.13.11.1RowalarmEntrynot-accessiblemandatory
1.3.6.1.4.1.39145.13.11.1.1ColumnalarmNumberread-onlymandatoryAlarm Input Number
1.3.6.1.4.1.39145.13.11.1.2ColumnalarmNameread-onlymandatoryAlarm Input Name
1.3.6.1.4.1.39145.13.11.1.3ColumnalarmStatusread-onlymandatoryAlarm Input Status ('1' indicates Alarm is INACTIVE,'2' indicates Alarm is READY, and '3' indicates Alarm is in an ALARM condition)
1.3.6.1.4.1.39145.13.12ScalarbatteryTemperatureread-onlymandatoryBattery Temperature (ºC) (a value of '1000' indicates the temperature probe is not connected)
1.3.6.1.4.1.39145.13.13ScalarbatterySocread-onlymandatoryBattery State of Charge (%)
1.3.6.1.4.1.39145.13.14ScalarbatteryNetAhread-onlymandatoryBattery Net Ah Count (Ah)
1.3.6.1.4.1.39145.13.15ScalarbatteryRunTimeread-onlymandatoryEstimated Battery Run-time Remaining (min)
1.3.6.1.4.1.39145.13.101NodemoduleAlarmTrapTrap generated when a Module Alarm is triggered
1.3.6.1.4.1.39145.13.102NodealarmInputTrapTrap generated when an Alarm Input is activated
1.3.6.1.4.1.39145.13.103NodeacFailAlarmTrapTrap generated when the AC Failure Alarm is triggered
1.3.6.1.4.1.39145.13.104NodesysCurrentLimitTrapTrap generated when the System Current Limit Alarm is triggered
1.3.6.1.4.1.39145.13.111NodemoduleAlarmClearTrap generated when a Module Alarm is cleared
1.3.6.1.4.1.39145.13.112NodealarmInputClearTrap generated when an Alarm Input is cleared
1.3.6.1.4.1.39145.13.113NodeacFailAlarmClearTrap generated when the AC Failure Alarm is cleared
1.3.6.1.4.1.39145.13.114NodesysCurrentLimitClearTrap generated when the System Current Limit Alarm is cleared
1.3.6.1.4.1.39145.13.121NodebatteryTestStartTrap generated when a Battery Discharge Test is started
1.3.6.1.4.1.39145.13.122NodebatteryTestCompleteTrap generated when a Battery Discharge Test completes successfully
1.3.6.1.4.1.39145.13.123NodebatteryTestFailTrap generated when a Battery Discharge Test fails
1.3.6.1.4.1.39145.13.124NodebatteryEqualiseStartTrap generated when a Battery Equalise Charge is started
1.3.6.1.4.1.39145.13.125NodebatteryEqualiseCompleteTrap generated when a Battery Equalise Charge completes