ICT-MODULAR-POWER-MIB
47 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises IpAddress |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.39145 | NodeictPower | |||
| 1.3.6.1.4.1.39145.13 | NodepowerSystem | |||
| 1.3.6.1.4.1.39145.13.1 | ScalardeviceModel | read-only | mandatory | Model Number |
| 1.3.6.1.4.1.39145.13.2 | ScalardeviceName | read-only | mandatory | Device Name |
| 1.3.6.1.4.1.39145.13.3 | ScalardeviceHardware | read-only | mandatory | Hardware Version |
| 1.3.6.1.4.1.39145.13.4 | ScalardeviceFirmware | read-only | mandatory | Firmware Version |
| 1.3.6.1.4.1.39145.13.5 | ScalardeviceMacAddress | read-only | mandatory | MAC Address |
| 1.3.6.1.4.1.39145.13.6 | ScalarinputVoltage | read-only | mandatory | Input Voltage (VAC) |
| 1.3.6.1.4.1.39145.13.7 | ScalaroutputVoltage | read-only | mandatory | Output Voltage (VDC) |
| 1.3.6.1.4.1.39145.13.8 | ScalaroutputCurrent | read-only | mandatory | Total System Current (Amps) |
| 1.3.6.1.4.1.39145.13.9 | ScalaroutputEnable | read-write | mandatory | Output Enable Status (a value of '1' indicates Output is Enabled, and a value of '2' indicates Output is Disabled. Output cannot be disabled during an AC Failu… |
| 1.3.6.1.4.1.39145.13.10 | TablemoduleTable | not-accessible | mandatory | Module Table |
| 1.3.6.1.4.1.39145.13.10.1 | RowmoduleEntry | not-accessible | mandatory | |
| 1.3.6.1.4.1.39145.13.10.1.1 | ColumnmoduleNumber | read-only | mandatory | Module Number |
| 1.3.6.1.4.1.39145.13.10.1.2 | ColumnmoduleStatus | read-only | mandatory | Module Status |
| 1.3.6.1.4.1.39145.13.10.1.3 | ColumnmoduleType | read-only | mandatory | Module Type ('1' indicates Module is NOT INSTALLED,'2' indicates POWER Module,'3' indicates BATTERY Module,'4' indicates DISTRIBUTION Module, and '5' indicates… |
| 1.3.6.1.4.1.39145.13.10.1.4 | ColumnmoduleVoltage | read-only | mandatory | Module Voltage (VDC) |
| 1.3.6.1.4.1.39145.13.10.1.5 | ColumnmoduleCurrentA | read-only | mandatory | Channel 1 Current (Amps) |
| 1.3.6.1.4.1.39145.13.10.1.6 | ColumnmoduleCurrentB | read-only | mandatory | Channel 2 Current (Amps) |
| 1.3.6.1.4.1.39145.13.10.1.7 | ColumnmoduleCurrentC | read-only | mandatory | Channel 3 Current (Amps) |
| 1.3.6.1.4.1.39145.13.10.1.8 | ColumnmoduleCurrentD | read-only | mandatory | Channel 4 Current (Amps) |
| 1.3.6.1.4.1.39145.13.10.1.9 | ColumnmoduleControlA | read-write | mandatory | Channel 1 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled) |
| 1.3.6.1.4.1.39145.13.10.1.10 | ColumnmoduleControlB | read-write | mandatory | Channel 2 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled) |
| 1.3.6.1.4.1.39145.13.10.1.11 | ColumnmoduleControlC | read-write | mandatory | Channel 3 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled) |
| 1.3.6.1.4.1.39145.13.10.1.12 | ColumnmoduleControlD | read-write | mandatory | Channel 4 Control (a value of '1' indicates Channel is Enabled, and a value of '2' indicates Channel is Disabled) |
| 1.3.6.1.4.1.39145.13.11 | TablealarmTable | not-accessible | mandatory | Alarm Input Table |
| 1.3.6.1.4.1.39145.13.11.1 | RowalarmEntry | not-accessible | mandatory | |
| 1.3.6.1.4.1.39145.13.11.1.1 | ColumnalarmNumber | read-only | mandatory | Alarm Input Number |
| 1.3.6.1.4.1.39145.13.11.1.2 | ColumnalarmName | read-only | mandatory | Alarm Input Name |
| 1.3.6.1.4.1.39145.13.11.1.3 | ColumnalarmStatus | read-only | mandatory | Alarm Input Status ('1' indicates Alarm is INACTIVE,'2' indicates Alarm is READY, and '3' indicates Alarm is in an ALARM condition) |
| 1.3.6.1.4.1.39145.13.12 | ScalarbatteryTemperature | read-only | mandatory | Battery Temperature (ºC) (a value of '1000' indicates the temperature probe is not connected) |
| 1.3.6.1.4.1.39145.13.13 | ScalarbatterySoc | read-only | mandatory | Battery State of Charge (%) |
| 1.3.6.1.4.1.39145.13.14 | ScalarbatteryNetAh | read-only | mandatory | Battery Net Ah Count (Ah) |
| 1.3.6.1.4.1.39145.13.15 | ScalarbatteryRunTime | read-only | mandatory | Estimated Battery Run-time Remaining (min) |
| 1.3.6.1.4.1.39145.13.101 | NodemoduleAlarmTrap | Trap generated when a Module Alarm is triggered | ||
| 1.3.6.1.4.1.39145.13.102 | NodealarmInputTrap | Trap generated when an Alarm Input is activated | ||
| 1.3.6.1.4.1.39145.13.103 | NodeacFailAlarmTrap | Trap generated when the AC Failure Alarm is triggered | ||
| 1.3.6.1.4.1.39145.13.104 | NodesysCurrentLimitTrap | Trap generated when the System Current Limit Alarm is triggered | ||
| 1.3.6.1.4.1.39145.13.111 | NodemoduleAlarmClear | Trap generated when a Module Alarm is cleared | ||
| 1.3.6.1.4.1.39145.13.112 | NodealarmInputClear | Trap generated when an Alarm Input is cleared | ||
| 1.3.6.1.4.1.39145.13.113 | NodeacFailAlarmClear | Trap generated when the AC Failure Alarm is cleared | ||
| 1.3.6.1.4.1.39145.13.114 | NodesysCurrentLimitClear | Trap generated when the System Current Limit Alarm is cleared | ||
| 1.3.6.1.4.1.39145.13.121 | NodebatteryTestStart | Trap generated when a Battery Discharge Test is started | ||
| 1.3.6.1.4.1.39145.13.122 | NodebatteryTestComplete | Trap generated when a Battery Discharge Test completes successfully | ||
| 1.3.6.1.4.1.39145.13.123 | NodebatteryTestFail | Trap generated when a Battery Discharge Test fails | ||
| 1.3.6.1.4.1.39145.13.124 | NodebatteryEqualiseStart | Trap generated when a Battery Equalise Charge is started | ||
| 1.3.6.1.4.1.39145.13.125 | NodebatteryEqualiseComplete | Trap generated when a Battery Equalise Charge completes |