ICT-SINE-WAVE-MIB

27 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMIenterprises IpAddress
RFC1213-MIBDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.39145NodeictPower
1.3.6.1.4.1.39145.12Nodeinverter
1.3.6.1.4.1.39145.12.1ScalardeviceModelread-onlymandatoryModel Number
1.3.6.1.4.1.39145.12.2ScalardeviceNameread-onlymandatorySite Name
1.3.6.1.4.1.39145.12.3ScalardeviceHardwareread-onlymandatoryHardware Version
1.3.6.1.4.1.39145.12.4ScalardeviceFirmwareread-onlymandatoryFirmware Version
1.3.6.1.4.1.39145.12.5ScalardeviceMacAddressread-onlymandatoryMAC Address
1.3.6.1.4.1.39145.12.6ScalarbatteryVoltageread-onlymandatoryBattery Voltage (VDC)
1.3.6.1.4.1.39145.12.7ScalarinverterVoltageread-onlymandatoryInverter Output Voltage (VAC)
1.3.6.1.4.1.39145.12.8ScalarinverterPowerread-onlymandatoryInverter Output Power (%)
1.3.6.1.4.1.39145.12.9ScalarinverterStatusread-onlymandatoryInverter Output Status ('1' indicates the Inverter Output is ENABLED, and '2' indicates the Inverter Output is DISABLED)
1.3.6.1.4.1.39145.12.10ScalarinverterControlread-writemandatoryInverter Output Control (set to '1' to ENABLE the Inverter Output if no alarms are active, set to '2' to DISABLE the Inverter Output)
1.3.6.1.4.1.39145.12.11ScalartransferRelayStatusread-onlymandatoryTransfer Relay Status ('1' indicates the Output is connected to the INVERTER, and '2' indicates the Output is connected to the GRID)
1.3.6.1.4.1.39145.12.101NodeundervoltageAlarmTrapTrap generated when the Battery Input Undervoltage Alarm is triggered
1.3.6.1.4.1.39145.12.102NodeovervoltageAlarmTrapTrap generated when the Battery Input Overvoltage Alarm is triggered
1.3.6.1.4.1.39145.12.103NodeovertemperatureAlarmTrapTrap generated when the Overtemperature Alarm is triggered
1.3.6.1.4.1.39145.12.104NodeoutputFaultAlarmTrapTrap generated when the Inverter Output Fault Alarm is triggered
1.3.6.1.4.1.39145.12.105NodesystemFaultAlarmTrapTrap generated when the System Fault Alarm is triggered
1.3.6.1.4.1.39145.12.106NoderemoteSwitchAlarmTrapTrap generated when the Remote Switch accessory is activated
1.3.6.1.4.1.39145.12.111NodeundervoltageAlarmClearTrap generated when the Battery Input Undervoltage Alarm is cleared
1.3.6.1.4.1.39145.12.112NodeovervoltageAlarmClearTrap generated when the Battery Input Overvoltage Alarm is cleared
1.3.6.1.4.1.39145.12.113NodeovertemperatureAlarmClearTrap generated when the Overtemperature Alarm is cleared
1.3.6.1.4.1.39145.12.114NodeoutputFaultAlarmClearTrap generated when the Inverter Output Fault Alarm is cleared
1.3.6.1.4.1.39145.12.115NodesystemFaultAlarmClearTrap generated when the System Fault Alarm is cleared
1.3.6.1.4.1.39145.12.116NoderemoteSwitchAlarmClearTrap generated when the Remote Switch accessory is deactivated
1.3.6.1.4.1.39145.12.121NodeinverterPowerTrapTrap generated when the Output switches to Inverter (Battery) Power
1.3.6.1.4.1.39145.12.122NodegridPowerTrapTrap generated when the Output switches to Grid Power