MIB Viewer

IDRAC-MIB-SMIv2

1012 objects
This MIB defines MIB objects that make out-of-band iDRAC data available to SNMP management applications. It also defines the traps that iDRAC supports.
Imported Objects
SNMPv2-CONFNOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.674.10892.5IdentityoutOfBandGroupThis MIB defines MIB objects that make out-of-band iDRAC data available to SNMP management applications. It also defines the traps that iDRAC supports.
1.3.6.1.4.1.674.10892.5.1NodeinformationGroup
1.3.6.1.4.1.674.10892.5.1.1NoderacInfoGroup
1.3.6.1.4.1.674.10892.5.1.1.1ScalarracNameread-onlycurrentThis attribute defines the product name of a remote access card.
1.3.6.1.4.1.674.10892.5.1.1.2ScalarracShortNameread-onlycurrentThis attribute defines the short product name of a remote access card.
1.3.6.1.4.1.674.10892.5.1.1.3ScalarracDescriptionread-onlycurrentThis attribute defines the product description of a remote access card.
1.3.6.1.4.1.674.10892.5.1.1.4ScalarracManufacturerread-onlycurrentThis attribute defines the product manufacturer of a remote access card.
1.3.6.1.4.1.674.10892.5.1.1.5ScalarracVersionread-onlycurrentThis attribute defines the product version of a remote access card.
1.3.6.1.4.1.674.10892.5.1.1.6ScalarracURLread-onlycurrentThis attribute defines the out-of-band UI URL of a remote access card.
1.3.6.1.4.1.674.10892.5.1.1.7ScalarracTyperead-onlycurrentThis attribute defines the type of a remote access card.
1.3.6.1.4.1.674.10892.5.1.1.8ScalarracFirmwareVersionread-onlycurrentThis attribute defines the firmware version of a remote access card.
1.3.6.1.4.1.674.10892.5.1.2NodechassisInfoGroup
1.3.6.1.4.1.674.10892.5.1.2.1ScalarchassisServiceTagread-onlycurrentThis attribute defines the service tag of the modular chassis. The value is zero length if not a modular system.
1.3.6.1.4.1.674.10892.5.1.2.2ScalarchassisNameModularread-onlycurrentThis attribute defines the chassis name of the modular chassis. The value is zero length if not a modular system.
1.3.6.1.4.1.674.10892.5.1.2.3ScalarchassisModelModularread-onlycurrentThis attribute defines the model of the modular chassis. The value is zero length if not a modular system.
1.3.6.1.4.1.674.10892.5.1.3NodesystemInfoGroup
1.3.6.1.4.1.674.10892.5.1.3.1ScalarsystemFQDNread-onlycurrentThis attribute defines the fully qualified domain name of the system. For example, hostname.domainname.
1.3.6.1.4.1.674.10892.5.1.3.2ScalarsystemServiceTagread-onlycurrentThis attribute defines the service tag of the system.
1.3.6.1.4.1.674.10892.5.1.3.3ScalarsystemExpressServiceCoderead-onlycurrentThis attribute defines the express service code of the system.
1.3.6.1.4.1.674.10892.5.1.3.4ScalarsystemAssetTagread-onlycurrentThis attribute defines the asset tag of the system.
1.3.6.1.4.1.674.10892.5.1.3.5ScalarsystemBladeSlotNumberread-onlycurrentThis attribute defines the slot number of the system in the modular chassis.
1.3.6.1.4.1.674.10892.5.1.3.6ScalarsystemOSNameread-onlycurrentThis attribute defines the name of the operating system that the host is running.
1.3.6.1.4.1.674.10892.5.1.3.7ScalarsystemFormFactorread-onlycurrentThis attribute defines the form factor of the system.
1.3.6.1.4.1.674.10892.5.1.3.8ScalarsystemDataCenterNameread-onlycurrentThis attribute defines the Data Center locator of the system.
1.3.6.1.4.1.674.10892.5.1.3.9ScalarsystemAisleNameread-onlycurrentThis attribute defines the Aisle locator of the system.
1.3.6.1.4.1.674.10892.5.1.3.10ScalarsystemRackNameread-onlycurrentThis attribute defines the Rack locator of the system.
1.3.6.1.4.1.674.10892.5.1.3.11ScalarsystemRackSlotread-onlycurrentThis attribute defines the Rack Slot locator of the system.
1.3.6.1.4.1.674.10892.5.1.3.12ScalarsystemModelNameread-onlycurrentThis attribute defines the model name of the system.
1.3.6.1.4.1.674.10892.5.1.3.13ScalarsystemSystemIDread-onlycurrentThis attribute defines the system ID of the system.
1.3.6.1.4.1.674.10892.5.1.3.14ScalarsystemOSVersionread-onlycurrentThis attribute defines the version of the operating system that the host is running.
1.3.6.1.4.1.674.10892.5.1.3.15ScalarsystemRoomNameread-onlycurrentThis attribute defines the Room locator of the system.
1.3.6.1.4.1.674.10892.5.1.3.16ScalarsystemChassisSystemHeightread-onlycurrentThis attribute defines the height of the system, in 'U's. A U is a standard unit of measure for the height of a rack or rack-mountable component. (If not appli…
1.3.6.1.4.1.674.10892.5.1.3.17ScalarsystemBladeGeometryread-onlycurrentThis attribute defines the geometry for a modular system. (If not applicable, a 'no such name' error is returned.)
1.3.6.1.4.1.674.10892.5.1.3.18ScalarsystemNodeIDread-onlycurrentThis attribute defines the node ID of the system. The node ID provides a unique identifier for the system.
1.3.6.1.4.1.674.10892.5.1.3.19ScalarsystemOEMOSVersionread-onlycurrentThis attribute defines the OEM version of the operating system .
1.3.6.1.4.1.674.10892.5.1.3.20ScalarsystemLockdownModeread-onlycurrentThis attribute defines the system Lockdown mode is enabled or disabled.
1.3.6.1.4.1.674.10892.5.2NodestatusGroup
1.3.6.1.4.1.674.10892.5.2.1ScalarglobalSystemStatusread-onlycurrentThis attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Includes system, storage, IO device…
1.3.6.1.4.1.674.10892.5.2.2ScalarsystemLCDStatusread-onlycurrentThis attribute defines the system status as it is reflected by the LCD front panel. Not all system components may be included.
1.3.6.1.4.1.674.10892.5.2.3ScalarglobalStorageStatusread-onlycurrentThis attribute defines the overall storage status being monitored by the remote access card.
1.3.6.1.4.1.674.10892.5.2.4ScalarsystemPowerStateread-onlycurrentThis attribute defines the power state of the system.
1.3.6.1.4.1.674.10892.5.2.5ScalarsystemPowerUpTimeread-onlycurrentThis attribute defines the power-up time of the system in seconds.
1.3.6.1.4.1.674.10892.5.3NodealertGroup
1.3.6.1.4.1.674.10892.5.3.1NodealertVariablesGroup
1.3.6.1.4.1.674.10892.5.3.1.1ScalaralertMessageIDread-onlycurrentMessage ID of the event.
1.3.6.1.4.1.674.10892.5.3.1.2ScalaralertMessageread-onlycurrentMessage describing the alert.
1.3.6.1.4.1.674.10892.5.3.1.3ScalaralertCurrentStatusread-onlycurrentCurrent status of object causing the alert, if applicable.
1.3.6.1.4.1.674.10892.5.3.1.4ScalaralertSystemServiceTagread-onlycurrentService tag of the system.
1.3.6.1.4.1.674.10892.5.3.1.5ScalaralertSystemFQDNread-onlycurrentFully qualified domain name of the system.
1.3.6.1.4.1.674.10892.5.3.1.6ScalaralertFQDDread-onlycurrentFully qualified device descriptor of the device.
1.3.6.1.4.1.674.10892.5.3.1.7ScalaralertDeviceDisplayNameread-onlycurrentDisplay name of the device/FQDD.
1.3.6.1.4.1.674.10892.5.3.1.8ScalaralertMessageArgumentsread-onlycurrentConcatenated set of strings representing the message arguments of the event. Each message argument string is enclosed in double quotes, and there is a comma af…
1.3.6.1.4.1.674.10892.5.3.1.9ScalaralertChassisServiceTagread-onlycurrentFor modular systems, the service tag of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length).
1.3.6.1.4.1.674.10892.5.3.1.10ScalaralertChassisNameread-onlycurrentFor modular systems, the chassis name of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length).
1.3.6.1.4.1.674.10892.5.3.1.11ScalaralertRacFQDNread-onlycurrentFully qualified domain name of the remote access card.
1.3.6.1.4.1.674.10892.5.3.2NodealertTrapGroup
1.3.6.1.4.1.674.10892.5.3.2.1NodesystemAlertTrapGroup
1.3.6.1.4.1.674.10892.5.3.2.1.0.2089NotificationalertNetworkFailurecurrentNetwork failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2090NotificationalertNetworkWarningcurrentNetwork warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2091NotificationalertNetworkInformationcurrentNetwork information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2153NotificationalertFanFailurecurrentFan failure.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2154NotificationalertFanWarningcurrentFan warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2155NotificationalertFanInformationcurrentFan information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2161NotificationalertTemperatureProbeFailurecurrentTemperature sensor has detected a failure value.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2162NotificationalertTemperatureProbeWarningcurrentTemperature sensor has detected a warning value.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2163NotificationalertTemperatureProbeNormalcurrentTemperature sensor value is within range.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2169NotificationalertVoltageProbeFailurecurrentVoltage sensor has detected a failure value.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2170NotificationalertVoltageProbeWarningcurrentVoltage sensor has detected a warning value.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2171NotificationalertVoltageProbeNormalcurrentVoltage sensor reading is within range.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2177NotificationalertAmperageProbeFailurecurrentCurrent sensor has detected a failure value.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2178NotificationalertAmperageProbeWarningcurrentCurrent sensor has detected a warning value.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2179NotificationalertAmperageProbeNormalcurrentCurrent sensor reading is within range.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2185NotificationalertPowerSupplyFailurecurrentPower supply has detected a failure.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2186NotificationalertPowerSupplyWarningcurrentPower supply has detected a warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2187NotificationalertPowerSupplyNormalcurrentPower supply has returned to normal.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2209NotificationalertIntegratedDualSDModuleFailurecurrentIntegrated Dual SD Module failure.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2210NotificationalertIntegratedDualSDModuleWarningcurrentIntegrated Dual SD Module warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2211NotificationalertIntegratedDualSDModuleInformationcurrentIntegrated Dual SD Module information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2225NotificationalertBatteryFailurecurrentBattery has failed or battery is absent.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2226NotificationalertBatteryWarningcurrentBattery is low.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2227NotificationalertBatteryNormalcurrentBattery state has returned to normal; or battery presence had been detected.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2233NotificationalertAutomaticSystemRecoverycurrentAutomatic system recovery (ASR) was performed.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2241NotificationalertProcessorDeviceStatusFailurecurrentProcessor device status has detected a failure.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2242NotificationalertProcessorDeviceStatusWarningcurrentProcessor device status has detected a warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2243NotificationalertProcessorDeviceStatusNormalcurrentProcessor device status has returned to normal.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2249NotificationalertLinkStatusFailurecurrentLink status failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2250NotificationalertLinkStatusWarningcurrentLink status warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2251NotificationalertLinkStatusInformationcurrentLink status information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2265NotificationalertMemoryDeviceFailurecurrentMemory device status is critical.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2266NotificationalertMemoryDeviceWarningcurrentMemory device status is noncritical.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2267NotificationalertMemoryDeviceInformationcurrentMemory device informational event.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2273NotificationalertPowerUsageFailurecurrentThe system halted because system power exceeds capacity; or the system performance degraded because power draw exceeds the power threshold.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2274NotificationalertPowerUsageWarningcurrentSystem performance degraded.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2275NotificationalertPowerUsageInformationcurrentSystem performance restored.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2297NotificationalertPhysicalDiskFailurecurrentPhysical disk failure.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2298NotificationalertPhysicalDiskWarningcurrentPhysical disk warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2299NotificationalertPhysicalDiskInformationcurrentPhysical disk information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2329NotificationalertHardwareConfigurationFailurecurrentHardware configuration failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2330NotificationalertHardwareConfigurationWarningcurrentHardware configuration warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2331NotificationalertHardwareConfigurationInformationcurrentHardware configuration information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2337NotificationalertSoftwareConfigurationFailurecurrentSoftware configuration failure.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2338NotificationalertSoftwareConfigurationWarningcurrentSoftware configuration warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2339NotificationalertSoftwareConfigurationInformationcurrentSoftware configuration information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2377NotificationalertSystemEventLogFailurecurrentSystem Event Log failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2378NotificationalertSystemEventLogWarningcurrentSystem Event Log warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2379NotificationalertSystemEventLogInformationcurrentSystem Event Log information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2385NotificationalertSecurityFailurecurrentSecurity failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2386NotificationalertSecurityWarningcurrentSecurity warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2387NotificationalertSecurityInformationcurrentSecurity information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2393NotificationalertCableFailurecurrentCable failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2409NotificationalertOSFailurecurrentA critical stop occurred during OS load; or a runtime critical stop occurred.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2411NotificationalertOSInformationcurrentAn OS graceful stop occurred; or an OS graceful shut-down occurred.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2417NotificationalertPCIDeviceFailurecurrentAn error was detected for a PCI device.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2418NotificationalertPCIDeviceWarningcurrentA warning event was detected for a PCI device.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2419NotificationalertPCIDeviceInformationcurrentAn informational event was detected for a PCI device.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2425NotificationalertBiosPostFailurecurrentSystem BIOS detected a failure.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2433NotificationalertInternaliDRACMemoryUnresponsivecurrentUnable to communicate with internal iDRAC memory
1.3.6.1.4.1.674.10892.5.3.2.1.0.2435NotificationalertServerIdleTimecurrentServer is either idle or underutilized
1.3.6.1.4.1.674.10892.5.3.2.1.0.2457NotificationalertProcessorDeviceAbsentcurrentProcessor device is absent.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2465NotificationalertPowerSupplyAbsentcurrentPower supply is absent.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2473NotificationalertRedundancyLostcurrentRedundancy is lost.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2474NotificationalertRedundancyDegradedcurrentRedundancy is degraded.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2475NotificationalertRedundancyInformationcurrentRedundancy information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2481NotificationalertIntegratedDualSDModuleAbsentcurrentIntegrated Dual SD Module is absent.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2489NotificationalertIntegratedDualSDModuleRedundancyLostcurrentIntegrated Dual SD Module redundancy is lost.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2490NotificationalertIntegratedDualSDModuleRedundancyDegradedcurrentIntegrated Dual SD Module redundancy is degraded.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2491NotificationalertIntegratedDualSDModuleRedundancyInformationcurrentIntegrated Dual SD Module redundancy information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2505NotificationalertvFlashMediaDeviceFailurecurrentvFlash Media device failure.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2506NotificationalertvFlashMediaDeviceWarningcurrentvFlash Media device warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2507NotificationalertvFlashMediaDeviceInformationcurrentvFlash Media device information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2515NotificationalertvFlashMediaDeviceAbsentcurrentvFlash Media device is absent.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2521NotificationalertTemperatureStatisticsFailurecurrentTemperature has been above the warning or critical threshold level for a long enough period of time to be considered in a critical state.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2522NotificationalertTemperatureStatisticsWarningcurrentTemperature has been above the warning or critical threshold level for a long enough period of time to be considered in a warning state.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2531NotificationalertRACInformationcurrentRAC information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2537NotificationalertFiberChannelFailurecurrentFiber Channel failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2538NotificationalertFiberChannelWarningcurrentFiber Channel warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2539NotificationalertFiberChannelInformationcurrentFiber Channel information.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2545NotificationalertCMCFailurecurrentChassis Management Controller detected an error.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2546NotificationalertCMCWarningcurrentChassis Management Controller detected a warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2553NotificationalertIOVirtualizationFailurecurrentIO Virtualization failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.1.0.2650NotificationalertSystemPerformanceWarningcurrentSystem Performance warning.
1.3.6.1.4.1.674.10892.5.3.2.1.0.3049NotificationalertLiquidCoolingLeakFailurecurrentA large leak is detected on the device
1.3.6.1.4.1.674.10892.5.3.2.1.0.3050NotificationalertLiquidCoolingLeakWarningcurrentA small leak is detected on the device
1.3.6.1.4.1.674.10892.5.3.2.1.0.3051NotificationalertLiquidCoolingLeakInformationalcurrentA small leak that was earlier detected on the device is now resolved.
1.3.6.1.4.1.674.10892.5.3.2.1.0.3082NotificationalertSDKSystemWarningcurrentThe iDRAC generated a trap event due to a warning from SDK plugin.
1.3.6.1.4.1.674.10892.5.3.2.1.0.3083NotificationalertSDKSystemInformationalcurrentThe iDRAC generated a trap as iDRAC SDK plugin started working as expected.
1.3.6.1.4.1.674.10892.5.3.2.1.0.3289NotificationalertSDPMSystemCriticalcurrentA System Defined Persistent Memory(SDPM) error is detected on the device
1.3.6.1.4.1.674.10892.5.3.2.1.0.3290NotificationalertSDPMSystemWarningcurrentThe iDRAC generated a trap event due to a warning from Software Defined Persistent Memory(SDPM).
1.3.6.1.4.1.674.10892.5.3.2.1.0.3291NotificationalertSDPMSystemInformationalcurrentThe iDRAC generated a trap as iDRAC Software Defined Persistent Memory(SDPM) started working as expected.
1.3.6.1.4.1.674.10892.5.3.2.1.0.9441NotificationalertCertificateValidityErrorcurrentCertificate Validity Failure or Critical event
1.3.6.1.4.1.674.10892.5.3.2.1.0.9442NotificationalertCertificateValidityWarningcurrentCertificate Validity State Change Warning
1.3.6.1.4.1.674.10892.5.3.2.2NodestorageAlertTrapGroup
1.3.6.1.4.1.674.10892.5.3.2.2.0.4177NotificationalertStorageManagementFailurecurrentStorage Management has detected a device independent error condition. There is no global status change associated with this trap.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4178NotificationalertStorageManagementWarningcurrentStorage Management has detected a device independent warning condition. There is no global status change associated with this trap.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4179NotificationalertStorageManagementInformationcurrentStorage Management Information. There is no global status change associated with this trap.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4201NotificationalertStorageFanFailurecurrentFan failure.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4202NotificationalertStorageFanWarningcurrentFan warning.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4203NotificationalertStorageFanInformationcurrentFan information.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4209NotificationalertStorageTemperatureProbeFailurecurrentTemperature probe failure.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4210NotificationalertStorageTemperatureProbeWarningcurrentTemperature probe warning.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4211NotificationalertStorageTemperatureProbeInformationcurrentTemperature probe information.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4233NotificationalertStoragePowerSupplyFailurecurrentPower supply failure.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4234NotificationalertStoragePowerSupplyWarningcurrentPower supply warning.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4235NotificationalertStoragePowerSupplyInformationcurrentPower supply information.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4273NotificationalertStorageBatteryFailurecurrentBattery failure.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4274NotificationalertStorageBatteryWarningcurrentBattery warning.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4275NotificationalertStorageBatteryInformationcurrentBattery information.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4329NotificationalertStorageControllerFailurecurrentController failure.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4330NotificationalertStorageControllerWarningcurrentController warning.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4331NotificationalertStorageControllerInformationcurrentController information.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4337NotificationalertStorageEnclosureFailurecurrentEnclosure failure.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4338NotificationalertStorageEnclosureWarningcurrentEnclosure warning.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4339NotificationalertStorageEnclosureInformationcurrentEnclosure information.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4345NotificationalertStoragePhysicalDiskFailurecurrentPhysical disk failure.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4346NotificationalertStoragePhysicalDiskWarningcurrentPhysical disk warning.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4347NotificationalertStoragePhysicalDiskInformationcurrentPhysical disk information.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4353NotificationalertStorageVirtualDiskFailurecurrentVirtual disk failure.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4354NotificationalertStorageVirtualDiskWarningcurrentVirtual disk warning.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4355NotificationalertStorageVirtualDiskInformationcurrentVirtual disk information.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4370NotificationalertStorageSolidstateDrivecurrentSSD is less than the threshold value.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4433NotificationalertStorageSecurityFailurecurrentStorage Security failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4434NotificationalertStorageSecurityWarningcurrentStorage Security warning.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4435NotificationalertStorageSecurityInformationcurrentStorage Security information.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4761NotificationalertStorageSoftwareDefinedSubSystemFailurecurrentSoftware defined storage subsystem failure.
1.3.6.1.4.1.674.10892.5.3.2.2.0.4762NotificationalertStorageSoftwareDefinedSubSystemWarningcurrentSoftware defined storage subsystem warning.
1.3.6.1.4.1.674.10892.5.3.2.3NodeupdatesAlertTrapGroup
1.3.6.1.4.1.674.10892.5.3.2.3.0.6211NotificationalertUpdateJobInformationcurrentUpdate job information.
1.3.6.1.4.1.674.10892.5.3.2.3.0.6314NotificationalertSoftwareChangeUpdateWarningcurrentSoftware change update warning.
1.3.6.1.4.1.674.10892.5.3.2.4NodeauditAlertTrapGroup
1.3.6.1.4.1.674.10892.5.3.2.4.0.8305NotificationalertTemperatureProbeChangeFailurecurrentTemperature increase Error.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8306NotificationalertTemperatureProbeReadWarningcurrentUnable to read Temperature Sensors
1.3.6.1.4.1.674.10892.5.3.2.4.0.8329NotificationalertPowerSupplyAuditFailurecurrentPower Supply audit failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8330NotificationalertPowerSupplyAuditWarningcurrentPower Supply audit warning.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8417NotificationalertPowerUsageAuditFailurecurrentPower usage audit failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8418NotificationalertPowerUsageAuditWarningcurrentPower usage audit warning.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8419NotificationalertPowerUsageAuditInformationcurrentPower usage audit information.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8474NotificationalertHWCAuditWarningcurrentHardware Configuration warning.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8475NotificationalertHWCAuditInformationcurrentHardware Configuration Information.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8490NotificationalertUserTrackingWarningcurrentUser Tracking warning.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8499NotificationalertiDRACIPAddressChangecurrentiDRAC IP address has changed.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8513NotificationalertLicenseFailurecurrentLicense failure.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8514NotificationalertLicenseWarningcurrentLicense warning.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8515NotificationalertLicenseInformationcurrentLicense information.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8562NotificationalertPCIDeviceAuditWarningcurrentPCI device audit warning.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8579NotificationalertSystemPowerStateChangeInformationcurrentHost is going through a power state change (powering on or powering off).
1.3.6.1.4.1.674.10892.5.3.2.4.0.8594NotificationalertDebugWarningcurrentDebug authorization failed.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8595NotificationalertDebugInformationcurrentDebug authorized.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8674NotificationalertRacConfigurationChangeWarningcurrentConfiguration or state Change warning.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8675NotificationalertRacConfigurationChangeInformationcurrentConfiguration or state Change Information.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8689NotificationalertCMCAuditFailurecurrentChassis Management Controller audit failure or critical event.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8690NotificationalertCMCAuditWarningcurrentChassis Management Controller audit warning.
1.3.6.1.4.1.674.10892.5.3.2.4.0.8691NotificationalertCMCAuditInformationcurrentChassis Management Controller audit information.
1.3.6.1.4.1.674.10892.5.3.2.5NodeconfigurationAlertTrapGroup
1.3.6.1.4.1.674.10892.5.3.2.5.0.10267NotificationalertJobControlConfigurationInformationcurrentJob Control configuration information.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10298NotificationalertPRDeviceDetectionWarningcurrentThe indicated device is not detected.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10395NotificationalertTestTrapEventcurrentThe iDRAC generated a test trap event in response to a user request.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10529NotificationalertSWCConfigurationFailurecurrentSoftware configuration failure.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10530NotificationalertSWCConfigurationWarningcurrentSoftware configuration warning.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10531NotificationalertSWCConfigurationInformationcurrentSoftware configuration Information.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10547NotificationalertIPAddressConfigurationInformationcurrentIP Address configuration information.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10578NotificationalertSecurityConfigurationWarningcurrentSecurity configuration warning.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10611NotificationalertPCIDeviceConfigurationInformationcurrentPCI device configuration information.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10627NotificationalertSystemConfigurationChangeInformationcurrentA/Many System Configuration Item/Items are changed.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10635NotificationalertAutoDiscoveryInformationcurrentAuto discovery information.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10770NotificationalertNetworkConfigurationWarningcurrentNetwork configuration warning.
1.3.6.1.4.1.674.10892.5.3.2.5.0.10771NotificationalertNetworkConfigurationInformationcurrentNetwork configuration information.
1.3.6.1.4.1.674.10892.5.3.2.5.0.11274NotificationalertSDKConfigurationWarningcurrentThe iDRAC generated a trap event with SDK plugin configuration change warning.
1.3.6.1.4.1.674.10892.5.3.2.5.0.11275NotificationalertSDKConfigurationInformationcurrentThe iDRAC generated a trap event with SDK plugin Configuration change information.
1.3.6.1.4.1.674.10892.5.4NodesystemDetailsGroup
1.3.6.1.4.1.674.10892.5.4.1NodemIBVersionGroup
1.3.6.1.4.1.674.10892.5.4.1.1ScalarmIBMajorVersionNumberread-onlycurrent0001.0001 This attribute defines the major version number for the version of this MIB supported by the iDRAC.
1.3.6.1.4.1.674.10892.5.4.1.2ScalarmIBMinorVersionNumberread-onlycurrent0001.0002 This attribute defines the minor version number for the version of this MIB supported by the iDRAC.
1.3.6.1.4.1.674.10892.5.4.1.3ScalarmIBMaintenanceVersionNumberread-onlycurrent0001.0003 This attribute defines the maintenance version number for the version of this MIB supported by the iDRAC.
1.3.6.1.4.1.674.10892.5.4.200NodesystemStateGroup
1.3.6.1.4.1.674.10892.5.4.200.10TablesystemStateTablenot-accessiblecurrent0200.0010 This object defines the System State Table.
1.3.6.1.4.1.674.10892.5.4.200.10.1RowsystemStateTableEntrynot-accessiblecurrent0200.0010.0001 This object defines the System State Table Entry.
1.3.6.1.4.1.674.10892.5.4.200.10.1.1ColumnsystemStatechassisIndexread-onlycurrent0200.0010.0001.0001 This attribute defines the index (one based) of this system chassis.
1.3.6.1.4.1.674.10892.5.4.200.10.1.2ColumnsystemStateGlobalSystemStatusread-onlycurrent0200.0010.0001.0002 This attribute defines the global system status of all system chassis being monitored by the systems management software.
1.3.6.1.4.1.674.10892.5.4.200.10.1.3ColumnsystemStateChassisStateread-onlycurrent0200.0010.0001.0003 This attribute defines the state settings of this system chassis.
1.3.6.1.4.1.674.10892.5.4.200.10.1.4ColumnsystemStateChassisStatusread-onlycurrent0200.0010.0001.0004 This attribute defines the status of this system chassis.
1.3.6.1.4.1.674.10892.5.4.200.10.1.5ColumnsystemStatePowerUnitStateDetailsread-onlycurrent0200.0010.0001.0005 This attribute lists the state settings of each power unit of this system. The results are returned as a binary octet string where each byt…
1.3.6.1.4.1.674.10892.5.4.200.10.1.6ColumnsystemStatePowerUnitStatusRedundancyread-onlycurrent0200.0010.0001.0006 This attribute defines the combined redundancy status of all power units of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.7ColumnsystemStatePowerUnitStatusDetailsread-onlycurrent0200.0010.0001.0007 This attribute lists the redundancy status of each power unit of this system. The results are returned as a binary octet string where each …
1.3.6.1.4.1.674.10892.5.4.200.10.1.8ColumnsystemStatePowerSupplyStateDetailsread-onlycurrent0200.0010.0001.0008 This attribute lists the state settings of each power supply of this system. The results are returned as a binary octet string where each b…
1.3.6.1.4.1.674.10892.5.4.200.10.1.9ColumnsystemStatePowerSupplyStatusCombinedread-onlycurrent0200.0010.0001.0009 This attribute defines the combined status of all power supplies of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.10ColumnsystemStatePowerSupplyStatusDetailsread-onlycurrent0200.0010.0001.0010 This attribute lists the status of each power supply of this system. The results are returned as a binary octet string where each byte of t…
1.3.6.1.4.1.674.10892.5.4.200.10.1.11ColumnsystemStateVoltageStateDetailsread-onlycurrent0200.0010.0001.0011 This attribute lists the state settings of each voltage probe of this system. The results are returned as a binary octet string where each …
1.3.6.1.4.1.674.10892.5.4.200.10.1.12ColumnsystemStateVoltageStatusCombinedread-onlycurrent0200.0010.0001.0012 This attribute defines the combined status of all voltage probes of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.13ColumnsystemStateVoltageStatusDetailsread-onlycurrent0200.0010.0001.0013 This attribute lists the status of each voltage probe of this system. The results are returned as a binary octet string where each byte of …
1.3.6.1.4.1.674.10892.5.4.200.10.1.14ColumnsystemStateAmperageStateDetailsread-onlycurrent0200.0010.0001.0014 This attribute lists the state settings of each amperage probe of this system. The results are returned as a binary octet string where each…
1.3.6.1.4.1.674.10892.5.4.200.10.1.15ColumnsystemStateAmperageStatusCombinedread-onlycurrent0200.0010.0001.0015 This attribute defines the combined status of all amperage probes of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.16ColumnsystemStateAmperageStatusDetailsread-onlycurrent0200.0010.0001.0016 This attribute lists the status of each amperage probe of this system. The results are returned as a binary octet string where each byte of…
1.3.6.1.4.1.674.10892.5.4.200.10.1.17ColumnsystemStateCoolingUnitStateDetailsread-onlycurrent0200.0010.0001.0017 This attribute lists the state settings of each cooling unit of this system. The results are returned as a binary octet string where each b…
1.3.6.1.4.1.674.10892.5.4.200.10.1.18ColumnsystemStateCoolingUnitStatusRedundancyread-onlycurrent0200.0010.0001.0018 This attribute defines the combined redundancy status of all cooling units of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.19ColumnsystemStateCoolingUnitStatusDetailsread-onlycurrent0200.0010.0001.0019 This attribute lists the redundancy status of each cooling unit of this system. The results are returned as a binary octet string where eac…
1.3.6.1.4.1.674.10892.5.4.200.10.1.20ColumnsystemStateCoolingDeviceStateDetailsread-onlycurrent0200.0010.0001.0020 This attribute lists the state settings of each cooling device of this system. The results are returned as a binary octet string where each…
1.3.6.1.4.1.674.10892.5.4.200.10.1.21ColumnsystemStateCoolingDeviceStatusCombinedread-onlycurrent0200.0010.0001.0021 This attribute defines the combined status of all cooling devices of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.22ColumnsystemStateCoolingDeviceStatusDetailsread-onlycurrent0200.0010.0001.0022 This attribute lists the status of each cooling device of this system. The results are returned as a binary octet string where each byte of…
1.3.6.1.4.1.674.10892.5.4.200.10.1.23ColumnsystemStateTemperatureStateDetailsread-onlycurrent0200.0010.0001.0023 This attribute lists the state settings of each temperature probe of this system. The results are returned as a binary octet string where e…
1.3.6.1.4.1.674.10892.5.4.200.10.1.24ColumnsystemStateTemperatureStatusCombinedread-onlycurrent0200.0010.0001.0024 This attribute defines the combined status of all temperature probes of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.25ColumnsystemStateTemperatureStatusDetailsread-onlycurrent0200.0010.0001.0025 This attribute lists the status of each temperature probe of this system. The results are returned as a binary octet string where each byte…
1.3.6.1.4.1.674.10892.5.4.200.10.1.26ColumnsystemStateMemoryDeviceStateDetailsread-onlycurrent0200.0010.0001.0026 This attribute lists the state settings of each memory device of this system. The results are returned as a binary octet string where each …
1.3.6.1.4.1.674.10892.5.4.200.10.1.27ColumnsystemStateMemoryDeviceStatusCombinedread-onlycurrent0200.0010.0001.0027 This attribute defines the combined status of all memory devices of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.28ColumnsystemStateMemoryDeviceStatusDetailsread-onlycurrent0200.0010.0001.0028 This attribute lists the status of each memory device of this system. The results are returned as a binary octet string where each byte of …
1.3.6.1.4.1.674.10892.5.4.200.10.1.29ColumnsystemStateChassisIntrusionStateDetailsread-onlycurrent0200.0010.0001.0029 This attribute lists the state settings of each intrusion detection device of this system chassis. The results are returned as a binary oct…
1.3.6.1.4.1.674.10892.5.4.200.10.1.30ColumnsystemStateChassisIntrusionStatusCombinedread-onlycurrent0200.0010.0001.0030 This attribute defines the combined status of all intrusion detection devices of this system chassis.
1.3.6.1.4.1.674.10892.5.4.200.10.1.31ColumnsystemStateChassisIntrusionStatusDetailsread-onlycurrent0200.0010.0001.0031 This attribute lists the status of each intrusion detection device of this system chassis. The results are returned as a binary octet strin…
1.3.6.1.4.1.674.10892.5.4.200.10.1.42ColumnsystemStatePowerUnitStatusCombinedread-onlycurrent0200.0010.0001.0042 This attribute defines the combined status of all power units of this chassis.
1.3.6.1.4.1.674.10892.5.4.200.10.1.43ColumnsystemStatePowerUnitStatusListread-onlycurrent0200.0010.0001.0043 This attribute lists the status of each power unit of this chassis. The results are returned as a binary octet string where each byte of th…
1.3.6.1.4.1.674.10892.5.4.200.10.1.44ColumnsystemStateCoolingUnitStatusCombinedread-onlycurrent0200.0010.0001.0044 This attribute defines the combined status of all cooling units of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.45ColumnsystemStateCoolingUnitStatusListread-onlycurrent0200.0010.0001.0045 This attribute lists the status of each cooling unit of this system. The results are returned as a binary octet string where each byte of t…
1.3.6.1.4.1.674.10892.5.4.200.10.1.50ColumnsystemStateProcessorDeviceStatusCombinedread-onlycurrent0200.0010.0001.0050 This attribute defines the combined status of all processor devices of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.51ColumnsystemStateProcessorDeviceStatusListread-onlycurrent0200.0010.0001.0051 This attribute lists the status of each processor device of this system. The results are returned as a binary octet string where each byte …
1.3.6.1.4.1.674.10892.5.4.200.10.1.52ColumnsystemStateBatteryStatusCombinedread-onlycurrent0200.0010.0001.0052 This attribute defines the combined status of all batteries of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.53ColumnsystemStateBatteryStatusListread-onlycurrent0200.0010.0001.0053 This attribute lists the status of each battery of this system. The results are returned as a binary octet string where each byte of the oc…
1.3.6.1.4.1.674.10892.5.4.200.10.1.54ColumnsystemStateSDCardUnitStatusCombinedread-onlycurrent0200.0010.0001.0054 This attribute defines the combined status of all SD Card units of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.55ColumnsystemStateSDCardUnitStatusListread-onlycurrent0200.0010.0001.0055 This attribute lists the status of each SD Card unit of this system. The results are returned as a binary octet string where each byte of t…
1.3.6.1.4.1.674.10892.5.4.200.10.1.56ColumnsystemStateSDCardDeviceStatusCombinedread-onlycurrent0200.0010.0001.0056 This attribute defines the combined status of all SD Card devices of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.57ColumnsystemStateSDCardDeviceStatusListread-onlycurrent0200.0010.0001.0057 This attribute lists the status of each SD Card device of this system. The results are returned as a binary octet string where each byte of…
1.3.6.1.4.1.674.10892.5.4.200.10.1.58ColumnsystemStateIDSDMCardUnitStatusCombinedread-onlycurrent0200.0010.0001.0058 This attribute defines the combined status of all IDSDM Card units of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.59ColumnsystemStateIDSDMCardUnitStatusListread-onlycurrent0200.0010.0001.0059 This attribute lists the status of each IDSDM Card unit of this system. The results are returned as a binary octet string where each byte o…
1.3.6.1.4.1.674.10892.5.4.200.10.1.60ColumnsystemStateIDSDMCardDeviceStatusCombinedread-onlycurrent0200.0010.0001.0060 This attribute defines the combined status of all IDSDM Card devices of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.61ColumnsystemStateIDSDMCardDeviceStatusListread-onlycurrent0200.0010.0001.0061 This attribute lists the status of each IDSDM Card device of this system. The results are returned as a binary octet string where each byte…
1.3.6.1.4.1.674.10892.5.4.200.10.1.62ColumnsystemStateTemperatureStatisticsStateDetailsread-onlycurrent0200.0010.0001.0062 This attribute lists the state settings of each temperature statistics object of this system. The results are returned as a binary octet st…
1.3.6.1.4.1.674.10892.5.4.200.10.1.63ColumnsystemStateTemperatureStatisticsStatusCombinedread-onlycurrent0200.0010.0001.0063 This attribute defines the combined status of all temperature statistics objects of this system.
1.3.6.1.4.1.674.10892.5.4.200.10.1.64ColumnsystemStateTemperatureStatisticsStatusDetailsread-onlycurrent0200.0010.0001.0064 This attribute lists the status of each temperature statistics object of this system. The results are returned as a binary octet string whe…
1.3.6.1.4.1.674.10892.5.4.200.10.1.65ColumnsystemStateCMCStatusread-onlycurrent0200.0010.0001.0065 This attribute defines the status of CMC.
1.3.6.1.4.1.674.10892.5.4.300NodechassisInformationGroup
1.3.6.1.4.1.674.10892.5.4.300.1ScalarnumEventLogEntriesread-onlycurrent0300.0001.0000 This attribute provides the number of entries currently in the eventLogTable.
1.3.6.1.4.1.674.10892.5.4.300.2ScalarnumLCLogEntriesread-onlycurrent0300.0002.0000 This attribute provides the number of entries currently in the lcLogTable. Note: This attribute can only be accessed via SNMPv3 queries.
1.3.6.1.4.1.674.10892.5.4.300.10TablechassisInformationTablenot-accessiblecurrent0300.0010 This object defines the Chassis Information Table.
1.3.6.1.4.1.674.10892.5.4.300.10.1RowchassisInformationTableEntrynot-accessiblecurrent0300.0010.0001 This object defines the Chassis Information Table Entry.
1.3.6.1.4.1.674.10892.5.4.300.10.1.1ColumnchassisIndexChassisInformationread-onlycurrent0300.0010.0001.0001 This attribute defines the index (one based) of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.2ColumnchassisStateCapabilitiesread-onlycurrent0300.0010.0001.0002 This attribute defines the state capabilities of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.3ColumnchassisStateSettingsread-onlycurrent0300.0010.0001.0003 This attribute defines the state settings of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.4ColumnchassisStatusread-onlycurrent0300.0010.0001.0004 This attribute defines the status of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.5ColumnchassisparentIndexReferenceread-onlycurrent0300.0010.0001.0005 This attribute defines the index (one based) to the parent system of this system chassis, if any.
1.3.6.1.4.1.674.10892.5.4.300.10.1.6ColumnchassisTyperead-onlycurrent0300.0010.0001.0006 This attribute defines the system type of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.7ColumnchassisNameread-onlycurrent0300.0010.0001.0007 This attribute defines the user-assigned name of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.8ColumnchassisManufacturerNameread-onlycurrent0300.0010.0001.0008 This attribute defines the name of the manufacturer of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.9ColumnchassisModelTypeNameread-onlycurrent0300.0010.0001.0009 This attribute defines the system model type of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.10ColumnchassisAssetTagNameread-onlycurrent0300.0010.0001.0010 This attribute defines the asset tag name of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.11ColumnchassisServiceTagNameread-onlycurrent0300.0010.0001.0011 This attribute defines the service tag name of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.12ColumnchassisIDread-onlycurrent0300.0010.0001.0012 This attribute defines the system ID. If the value is 254 (0xFE), the attribute systemIDExtension provides the system ID.
1.3.6.1.4.1.674.10892.5.4.300.10.1.13ColumnchassisIDExtensionread-onlycurrent0300.0010.0001.0013 This attribute defines the system ID extension.
1.3.6.1.4.1.674.10892.5.4.300.10.1.14ColumnchassisSystemClassread-onlycurrent0300.0010.0001.0014 This attribute defines the system class.
1.3.6.1.4.1.674.10892.5.4.300.10.1.15ColumnchassisSystemNameread-onlycurrent0300.0010.0001.0015 This attribute defines the host name of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.24ColumnchassisLEDControlCapabilitiesUniqueread-onlycurrent0300.0010.0001.0024 This attribute defines the capabilities of the LED control hardware in the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.25ColumnchassisLEDControlSettingsUniqueread-onlycurrent0300.0010.0001.0025 This attribute defines the reading and setting of the LED control hardware in the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.28ColumnchassisIdentifyFlashControlCapabilitiesread-onlycurrent0300.0010.0001.0028 This attribute defines if the system allows setting of the system front panel LED to flash.
1.3.6.1.4.1.674.10892.5.4.300.10.1.29ColumnchassisIdentifyFlashControlSettingsread-onlycurrent0300.0010.0001.0029 This attribute setting causes the system front panel LED to flash.
1.3.6.1.4.1.674.10892.5.4.300.10.1.30ColumnchassisLockPresentread-onlycurrent0300.0010.0001.0030 If true, a system lock is present on the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.31ColumnchassishostControlCapabilitiesUniqueread-onlycurrent0300.0010.0001.0031 This attribute defines the capabilities of the host control function.
1.3.6.1.4.1.674.10892.5.4.300.10.1.32ColumnchassishostControlSettingsUniqueread-onlycurrent0300.0010.0001.0032 This attribute defines the settings of the host control function.
1.3.6.1.4.1.674.10892.5.4.300.10.1.33ColumnchassiswatchDogControlCapabilitiesUniqueread-onlycurrent0300.0010.0001.0033 This attribute defines the capabilities of the watchdog control function.
1.3.6.1.4.1.674.10892.5.4.300.10.1.34ColumnchassiswatchDogControlSettingsUniqueread-onlycurrent0300.0010.0001.0034 This attribute defines the settings of the watchdog control function.
1.3.6.1.4.1.674.10892.5.4.300.10.1.35ColumnchassiswatchDogControlExpiryTimeCapabilitiesUniqueread-onlycurrent0300.0010.0001.0035 This attribute defines the capabilities of the watchdog control expiry timer function.
1.3.6.1.4.1.674.10892.5.4.300.10.1.36ColumnchassiswatchDogControlExpiryTimeread-onlycurrent0300.0010.0001.0036 This attribute defines the current watchdog timer value in seconds.
1.3.6.1.4.1.674.10892.5.4.300.10.1.38ColumnchassisPowerButtonControlCapabilitiesUniqueread-onlycurrent0300.0010.0001.0038 This attribute defines the capabilities of the power button control hardware in the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.39ColumnchassisPowerButtonControlSettingsUniqueread-onlycurrent0300.0010.0001.0039 This attribute defines the reading and setting of the power button control hardware in the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.44ColumnchassisNMIButtonControlCapabilitiesUniqueread-onlycurrent0300.0010.0001.0044 This attribute defines the capabilities of the NMI button control hardware in the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.45ColumnchassisNMIButtonControlSettingsUniqueread-onlycurrent0300.0010.0001.0045 This attribute defines the reading and setting of the NMI button control hardware in the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.46ColumnchassisSystemPropertiesread-onlycurrent0300.0010.0001.0046 This attribute defines the properties of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.10.1.47ColumnchassisSystemRevisionNumberread-onlycurrent0300.0010.0001.0047 This attribute defines the revision number of the system where zero indicates the original version of the system chassis. The revision numb…
1.3.6.1.4.1.674.10892.5.4.300.10.1.48ColumnchassisSystemRevisionNameread-onlycurrent0300.0010.0001.0048 This attribute defines the revision name of the system, if applicable.
1.3.6.1.4.1.674.10892.5.4.300.10.1.49ColumnchassisExpressServiceCodeNameread-onlycurrent0300.0010.0001.0049 This attribute defines the Express Service Code of the system chassis.
1.3.6.1.4.1.674.10892.5.4.300.40TableeventLogTablenot-accessiblecurrent0300.0040 This object defines the Event (ESM) Log Table.
1.3.6.1.4.1.674.10892.5.4.300.40.1RoweventLogTableEntrynot-accessiblecurrent0300.0040.0001 This object defines the Event (ESM) Log Table Entry.
1.3.6.1.4.1.674.10892.5.4.300.40.1.1ColumneventLogchassisIndexread-onlycurrent0300.0040.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.300.40.1.2ColumneventLogRecordIndexread-onlycurrent0300.0040.0001.0002 This attribute defines the index (one based) of the event log record.
1.3.6.1.4.1.674.10892.5.4.300.40.1.3ColumneventLogStateCapabilitiesUniqueread-onlycurrent0300.0040.0001.0003 This attribute defines the state capabilities of the object that is writing the event log.
1.3.6.1.4.1.674.10892.5.4.300.40.1.4ColumneventLogStateSettingsUniqueread-onlycurrent0300.0040.0001.0004 This attribute defines the state settings of the object that is writing the event log.
1.3.6.1.4.1.674.10892.5.4.300.40.1.5ColumneventLogRecordread-onlycurrent0300.0040.0001.0005 This attribute defines the data of the event log record.
1.3.6.1.4.1.674.10892.5.4.300.40.1.6ColumneventLogFormatread-onlycurrent0300.0040.0001.0006 This attribute defines the format of the event log record.
1.3.6.1.4.1.674.10892.5.4.300.40.1.7ColumneventLogSeverityStatusread-onlycurrent0300.0040.0001.0007 This attribute defines the severity of the event log record.
1.3.6.1.4.1.674.10892.5.4.300.40.1.8ColumneventLogDateNameread-onlycurrent0300.0040.0001.0008 This attribute defines the date and time of the event log record.
1.3.6.1.4.1.674.10892.5.4.300.50TablesystemBIOSTablenot-accessiblecurrent0300.0050 This object defines the System BIOS Table.
1.3.6.1.4.1.674.10892.5.4.300.50.1RowsystemBIOSTableEntrynot-accessiblecurrent0300.0050.0001 This object defines the System BIOS Table Entry.
1.3.6.1.4.1.674.10892.5.4.300.50.1.1ColumnsystemBIOSchassisIndexread-onlycurrent0300.0050.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.300.50.1.2ColumnsystemBIOSIndexread-onlycurrent0300.0050.0001.0002 This attribute defines the index (one based) of the system BIOS.
1.3.6.1.4.1.674.10892.5.4.300.50.1.3ColumnsystemBIOSStateCapabilitiesread-onlycurrent0300.0050.0001.0003 This attribute defines the state capabilities of the system BIOS.
1.3.6.1.4.1.674.10892.5.4.300.50.1.4ColumnsystemBIOSStateSettingsread-onlycurrent0300.0050.0001.0004 This attribute defines the state settings of the system BIOS.
1.3.6.1.4.1.674.10892.5.4.300.50.1.5ColumnsystemBIOSStatusread-onlycurrent0300.0050.0001.0005 This attribute defines the status of the system BIOS.
1.3.6.1.4.1.674.10892.5.4.300.50.1.7ColumnsystemBIOSReleaseDateNameread-onlycurrent0300.0050.0001.0007 This attribute defines the release date name of the system BIOS.
1.3.6.1.4.1.674.10892.5.4.300.50.1.8ColumnsystemBIOSVersionNameread-onlycurrent0300.0050.0001.0008 This attribute defines the version name of the system BIOS.
1.3.6.1.4.1.674.10892.5.4.300.50.1.11ColumnsystemBIOSManufacturerNameread-onlycurrent0300.0050.0001.0011 This attribute defines the name of the manufacturer of the system BIOS.
1.3.6.1.4.1.674.10892.5.4.300.60TablefirmwareTablenot-accessiblecurrent0300.0060 This object defines the Firmware Table.
1.3.6.1.4.1.674.10892.5.4.300.60.1RowfirmwareTableEntrynot-accessiblecurrent0300.0060.0001 This object defines the Firmware Table Entry.
1.3.6.1.4.1.674.10892.5.4.300.60.1.1ColumnfirmwarechassisIndexread-onlycurrent0300.0060.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.300.60.1.2ColumnfirmwareIndexread-onlycurrent0300.0060.0001.0002 This attribute defines the index (one based) of the firmware.
1.3.6.1.4.1.674.10892.5.4.300.60.1.3ColumnfirmwareStateCapabilitiesread-onlycurrent0300.0060.0001.0003 This attribute defines the state capabilities of the firmware.
1.3.6.1.4.1.674.10892.5.4.300.60.1.4ColumnfirmwareStateSettingsread-onlycurrent0300.0060.0001.0004 This attribute defines the state settings of the firmware.
1.3.6.1.4.1.674.10892.5.4.300.60.1.5ColumnfirmwareStatusread-onlycurrent0300.0060.0001.0005 This attribute defines the status of the firmware.
1.3.6.1.4.1.674.10892.5.4.300.60.1.6ColumnfirmwareSizeread-onlycurrent0300.0060.0001.0006 This attribute defines the image size of the firmware in KBytes. Zero indicates size is unknown.
1.3.6.1.4.1.674.10892.5.4.300.60.1.7ColumnfirmwareTyperead-onlycurrent0300.0060.0001.0007 This attribute defines the type of firmware.
1.3.6.1.4.1.674.10892.5.4.300.60.1.8ColumnfirmwareTypeNameread-onlycurrent0300.0060.0001.0008 This attribute defines the type name of the firmware.
1.3.6.1.4.1.674.10892.5.4.300.60.1.9ColumnfirmwareUpdateCapabilitiesread-onlycurrent0300.0060.0001.0009 This attribute defines the bitmap of supported methods for firmware update.
1.3.6.1.4.1.674.10892.5.4.300.60.1.11ColumnfirmwareVersionNameread-onlycurrent0300.0060.0001.0011 This attribute defines the version of the firmware.
1.3.6.1.4.1.674.10892.5.4.300.70TableintrusionTablenot-accessiblecurrent0300.0070 This object defines the Intrusion Table.
1.3.6.1.4.1.674.10892.5.4.300.70.1RowintrusionTableEntrynot-accessiblecurrent0300.0070.0001 This object defines the Intrusion Table Entry.
1.3.6.1.4.1.674.10892.5.4.300.70.1.1ColumnintrusionchassisIndexread-onlycurrent0300.0070.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.300.70.1.2ColumnintrusionIndexread-onlycurrent0300.0070.0001.0002 This attribute defines the index (one based) of the intrusion sensor.
1.3.6.1.4.1.674.10892.5.4.300.70.1.3ColumnintrusionStateCapabilitiesread-onlycurrent0300.0070.0001.0003 This attribute defines the state capabilities of the intrusion sensor.
1.3.6.1.4.1.674.10892.5.4.300.70.1.4ColumnintrusionStateSettingsread-onlycurrent0300.0070.0001.0004 This attribute defines the state settings of the intrusion sensor.
1.3.6.1.4.1.674.10892.5.4.300.70.1.5ColumnintrusionStatusread-onlycurrent0300.0070.0001.0005 This attribute defines the status of the intrusion sensor.
1.3.6.1.4.1.674.10892.5.4.300.70.1.6ColumnintrusionReadingread-onlycurrent0300.0070.0001.0006 This attribute defines the reading of the intrusion sensor.
1.3.6.1.4.1.674.10892.5.4.300.70.1.7ColumnintrusionTyperead-onlycurrent0300.0070.0001.0007 This attribute defines the type of the intrusion sensor.
1.3.6.1.4.1.674.10892.5.4.300.70.1.8ColumnintrusionLocationNameread-onlycurrent0300.0070.0001.0008 This attribute defines the location of the intrusion sensor.
1.3.6.1.4.1.674.10892.5.4.300.90TablelcLogTablenot-accessiblecurrent0300.0090 This object defines the Lifecycle (LC) Log Table. Lifecycle (LC) Log table records are ordered from oldest to newest. Note: This table can only be ac…
1.3.6.1.4.1.674.10892.5.4.300.90.1RowlcLogTableEntrynot-accessiblecurrent0300.0090.0001 This object defines the Lifcycle (LC) Log Table Entry.
1.3.6.1.4.1.674.10892.5.4.300.90.1.1ColumnlcLogChassisIndexread-onlycurrent0300.0090.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.300.90.1.2ColumnlcLogRecordIndexread-onlycurrent0300.0090.0001.0002 This attribute defines the index (one based) of the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.3ColumnlcLogSequenceNumberread-onlycurrent0300.0090.0001.0003 This attribute defines the LC Log sequence number of the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.4ColumnlcLogCategoryread-onlycurrent0300.0090.0001.0004 This attribute defines the category of the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.5ColumnlcLogSeverityStatusread-onlycurrent0300.0090.0001.0005 This attribute defines the severity of the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.6ColumnlcLogDateNameread-onlycurrent0300.0090.0001.0006 This attribute defines the date and time of the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.7ColumnlcLogFQDDread-onlycurrent0300.0090.0001.0007 Fully qualified device descriptor (FQDD) of the device associated with the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.8ColumnlcLogMessageIDread-onlycurrent0300.0090.0001.0008 This attribute defines the Message ID of the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.9ColumnlcLogMessageread-onlycurrent0300.0090.0001.0009 This attribute defines the message of the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.10ColumnlcLogDetailedDescriptionread-onlycurrent0300.0090.0001.0010 This attribute defines the detailed description of the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.11ColumnlcLogRecommededActionread-onlycurrent0300.0090.0001.0011 This attribute defines an optional recommended action associated with the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.300.90.1.12ColumnlcLogCommentread-onlycurrent0300.0090.0001.0012 This attribute defines an optional user comment associated with the event associated with the LC log record.
1.3.6.1.4.1.674.10892.5.4.600NodepowerGroup
1.3.6.1.4.1.674.10892.5.4.600.10TablepowerUnitTablenot-accessiblecurrent0600.0010 This object defines the Power Unit Table.
1.3.6.1.4.1.674.10892.5.4.600.10.1RowpowerUnitTableEntrynot-accessiblecurrent0600.0010.0001 This object defines the Power Unit Table Entry.
1.3.6.1.4.1.674.10892.5.4.600.10.1.1ColumnpowerUnitchassisIndexread-onlycurrent0600.0010.0001.0001 This attribute defines the index (one based) of the system chassis.
1.3.6.1.4.1.674.10892.5.4.600.10.1.2ColumnpowerUnitIndexread-onlycurrent0600.0010.0001.0002 This attribute defines the index (one based) of the power unit.
1.3.6.1.4.1.674.10892.5.4.600.10.1.3ColumnpowerUnitStateCapabilitiesread-onlycurrent0600.0010.0001.0003 This attribute defines the state capabilities of the power unit.
1.3.6.1.4.1.674.10892.5.4.600.10.1.4ColumnpowerUnitStateSettingsread-onlycurrent0600.0010.0001.0004 This attribute defines the state settings of the power unit.
1.3.6.1.4.1.674.10892.5.4.600.10.1.5ColumnpowerUnitRedundancyStatusread-onlycurrent0600.0010.0001.0005 This attribute defines the redundancy status of the power unit.
1.3.6.1.4.1.674.10892.5.4.600.10.1.6ColumnpowerSupplyCountForRedundancyread-onlycurrent0600.0010.0001.0006 This attribute defines the total number of power supplies required for this power unit to have full redundancy.
1.3.6.1.4.1.674.10892.5.4.600.10.1.7ColumnpowerUnitNameread-onlycurrent0600.0010.0001.0007 This attribute defines the name of the power unit.
1.3.6.1.4.1.674.10892.5.4.600.10.1.8ColumnpowerUnitStatusread-onlycurrent0600.0010.0001.0008 This attribute defines the status of the power unit.
1.3.6.1.4.1.674.10892.5.4.600.12TablepowerSupplyTablenot-accessiblecurrent0600.0012 This object defines the Power Supply Table.
1.3.6.1.4.1.674.10892.5.4.600.12.1RowpowerSupplyTableEntrynot-accessiblecurrent0600.0012.0001 This object defines the Power Supply Table Entry.
1.3.6.1.4.1.674.10892.5.4.600.12.1.1ColumnpowerSupplychassisIndexread-onlycurrent0600.0012.0001.0001 This attribute defines the index (one based) of the system chassis.
1.3.6.1.4.1.674.10892.5.4.600.12.1.2ColumnpowerSupplyIndexread-onlycurrent0600.0012.0001.0002 This attribute defines the index (one based) of the power supply.
1.3.6.1.4.1.674.10892.5.4.600.12.1.3ColumnpowerSupplyStateCapabilitiesUniqueread-onlycurrent0600.0012.0001.0003 This attribute defines the state capabilities of the power supply.
1.3.6.1.4.1.674.10892.5.4.600.12.1.4ColumnpowerSupplyStateSettingsUniqueread-onlycurrent0600.0012.0001.0004 This attribute defines the state settings of the power supply.
1.3.6.1.4.1.674.10892.5.4.600.12.1.5ColumnpowerSupplyStatusread-onlycurrent0600.0012.0001.0005 This attribute defines the status of the power supply.
1.3.6.1.4.1.674.10892.5.4.600.12.1.6ColumnpowerSupplyOutputWattsread-onlycurrent0600.0012.0001.0006 This attribute defines the maximum sustained output wattage of the power supply (in tenths of Watts).
1.3.6.1.4.1.674.10892.5.4.600.12.1.7ColumnpowerSupplyTyperead-onlycurrent0600.0012.0001.0007 This attribute defines the type of the power supply.
1.3.6.1.4.1.674.10892.5.4.600.12.1.8ColumnpowerSupplyLocationNameread-onlycurrent0600.0012.0001.0008 This attribute defines the location of the power supply.
1.3.6.1.4.1.674.10892.5.4.600.12.1.9ColumnpowerSupplyMaximumInputVoltageread-onlycurrent0600.0012.0001.0009 This attribute defines the maximum input voltage of the power supply (in Volts).
1.3.6.1.4.1.674.10892.5.4.600.12.1.10ColumnpowerSupplypowerUnitIndexReferenceread-onlycurrent0600.0012.0001.0010 This attribute defines the index to the associated power unit if the power supply is part of a power unit.
1.3.6.1.4.1.674.10892.5.4.600.12.1.11ColumnpowerSupplySensorStateread-onlycurrent0600.0012.0001.0011 This attribute defines the state reported by the power supply sensor. This attribute supplements the attribute powerSupplyStateSettingsUniq…
1.3.6.1.4.1.674.10892.5.4.600.12.1.12ColumnpowerSupplyConfigurationErrorTyperead-onlycurrent0600.0012.0001.0012 This attribute defines the type of configuration error reported by the power supply sensor. When the configurationError bit is on in the va…
1.3.6.1.4.1.674.10892.5.4.600.12.1.13ColumnpowerSupplyPowerMonitorCapableread-onlycurrent0600.0012.0001.0013 This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption.
1.3.6.1.4.1.674.10892.5.4.600.12.1.14ColumnpowerSupplyRatedInputWattageread-onlycurrent0600.0012.0001.0014 This attribute defines the rated input wattage of the power supply (in tenths of Watts).
1.3.6.1.4.1.674.10892.5.4.600.12.1.15ColumnpowerSupplyFQDDread-onlycurrent0600.0012.0001.0015 Fully qualified device descriptor (FQDD) of the power supply.
1.3.6.1.4.1.674.10892.5.4.600.12.1.16ColumnpowerSupplyCurrentInputVoltageread-onlycurrent0600.0012.0001.0016 This attribute defines the current input voltage to the power supply (in Volts).
1.3.6.1.4.1.674.10892.5.4.600.20TablevoltageProbeTablenot-accessiblecurrent0600.0020 This object defines the Voltage Probe Table.
1.3.6.1.4.1.674.10892.5.4.600.20.1RowvoltageProbeTableEntrynot-accessiblecurrent0600.0020.001 This object defines the Voltage Probe Table Entry.
1.3.6.1.4.1.674.10892.5.4.600.20.1.1ColumnvoltageProbechassisIndexread-onlycurrent0600.0020.0001.0001 This attribute defines the index (one based) of the system chassis.
1.3.6.1.4.1.674.10892.5.4.600.20.1.2ColumnvoltageProbeIndexread-onlycurrent0600.0020.0001.0002 This attribute defines the index (one based) of the voltage probe.
1.3.6.1.4.1.674.10892.5.4.600.20.1.3ColumnvoltageProbeStateCapabilitiesread-onlycurrent0600.0020.0001.0003 This attribute defines the state capabilities of the voltage probe.
1.3.6.1.4.1.674.10892.5.4.600.20.1.4ColumnvoltageProbeStateSettingsread-onlycurrent0600.0020.0001.0004 This attribute defines the state settings of the voltage probe.
1.3.6.1.4.1.674.10892.5.4.600.20.1.5ColumnvoltageProbeStatusread-onlycurrent0600.0020.0001.0005 This attribute defines the probe status of the voltage probe.
1.3.6.1.4.1.674.10892.5.4.600.20.1.6ColumnvoltageProbeReadingread-onlycurrent0600.0020.0001.0006 This attribute defines the reading for a voltage probe of type other than voltageProbeTypeIsDiscrete. When the value for voltageProbeType i…
1.3.6.1.4.1.674.10892.5.4.600.20.1.7ColumnvoltageProbeTyperead-onlycurrent0600.0020.0001.0007 This attribute defines the type of the voltage probe.
1.3.6.1.4.1.674.10892.5.4.600.20.1.8ColumnvoltageProbeLocationNameread-onlycurrent0600.0020.0001.0008 This attribute defines the location name of the voltage probe.
1.3.6.1.4.1.674.10892.5.4.600.20.1.9ColumnvoltageProbeUpperNonRecoverableThresholdread-onlycurrent0600.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the voltage probe. The value is an integer representing the voltage of the thr…
1.3.6.1.4.1.674.10892.5.4.600.20.1.10ColumnvoltageProbeUpperCriticalThresholdread-onlycurrent0600.0020.0001.0010 This attribute defines the upper critical threshold of the voltage probe. The value is an integer representing the voltage of the threshold…
1.3.6.1.4.1.674.10892.5.4.600.20.1.11ColumnvoltageProbeUpperNonCriticalThresholdread-onlycurrent0600.0020.0001.0011 This attribute defines the upper noncritical threshold of the voltage probe. The value is an integer representing the voltage of the thresh…
1.3.6.1.4.1.674.10892.5.4.600.20.1.12ColumnvoltageProbeLowerNonCriticalThresholdread-onlycurrent0600.0020.0001.0012 This attribute defines the lower noncritical threshold of the voltage probe. The value is an integer representing the voltage of the thresh…
1.3.6.1.4.1.674.10892.5.4.600.20.1.13ColumnvoltageProbeLowerCriticalThresholdread-onlycurrent0600.0020.0001.0013 This attribute defines the lower critical threshold of the voltage probe. The value is an integer representing the voltage of the threshold…
1.3.6.1.4.1.674.10892.5.4.600.20.1.14ColumnvoltageProbeLowerNonRecoverableThresholdread-onlycurrent0600.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the voltage probe. The value is an integer representing the voltage of the thr…
1.3.6.1.4.1.674.10892.5.4.600.20.1.15ColumnvoltageProbeProbeCapabilitiesread-onlycurrent0600.0020.0001.0015 This attribute defines the probe capabilities of the voltage probe.
1.3.6.1.4.1.674.10892.5.4.600.20.1.16ColumnvoltageProbeDiscreteReadingread-onlycurrent0600.0020.0001.0016 This attribute defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other tha…
1.3.6.1.4.1.674.10892.5.4.600.30TableamperageProbeTablenot-accessiblecurrent0600.0030 This object defines the Amperage Probe Table.
1.3.6.1.4.1.674.10892.5.4.600.30.1RowamperageProbeTableEntrynot-accessiblecurrent0600.0030.0001 This object defines the Amperage Probe Table Entry.
1.3.6.1.4.1.674.10892.5.4.600.30.1.1ColumnamperageProbechassisIndexread-onlycurrent0600.0030.0001.0001 This attribute defines the index (one based) of the system chassis.
1.3.6.1.4.1.674.10892.5.4.600.30.1.2ColumnamperageProbeIndexread-onlycurrent0600.0030.0001.0002 This attribute defines the index (one based) of the amperage probe.
1.3.6.1.4.1.674.10892.5.4.600.30.1.3ColumnamperageProbeStateCapabilitiesread-onlycurrent0600.0030.0001.0003 This attribute defines the state capabilities of the amperage probe.
1.3.6.1.4.1.674.10892.5.4.600.30.1.4ColumnamperageProbeStateSettingsread-onlycurrent0600.0030.0001.0004 This attribute defines the state settings of the amperage probe.
1.3.6.1.4.1.674.10892.5.4.600.30.1.5ColumnamperageProbeStatusread-onlycurrent0600.0030.0001.0005 This attribute defines the probe status of the amperage probe.
1.3.6.1.4.1.674.10892.5.4.600.30.1.6ColumnamperageProbeReadingread-onlycurrent0600.0030.0001.0006 This attribute defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete. When the value for amperageProbeTy…
1.3.6.1.4.1.674.10892.5.4.600.30.1.7ColumnamperageProbeTyperead-onlycurrent0600.0030.0001.0007 This attribute defines the type of the amperage probe.
1.3.6.1.4.1.674.10892.5.4.600.30.1.8ColumnamperageProbeLocationNameread-onlycurrent0600.0030.0001.0008 This attribute defines the location of the amperage probe.
1.3.6.1.4.1.674.10892.5.4.600.30.1.9ColumnamperageProbeUpperNonRecoverableThresholdread-onlycurrent0600.0030.0001.0009 This attribute defines the upper nonrecoverable threshold of the amperage probe. The value is an integer representing the amperage of the t…
1.3.6.1.4.1.674.10892.5.4.600.30.1.10ColumnamperageProbeUpperCriticalThresholdread-onlycurrent0600.0030.0001.0010 This attribute defines the upper critical threshold of the amperage probe. The value is an integer representing the amperage of the thresho…
1.3.6.1.4.1.674.10892.5.4.600.30.1.11ColumnamperageProbeUpperNonCriticalThresholdread-onlycurrent0600.0030.0001.0011 This attribute defines the upper noncritical threshold of the amperage probe. The value is an integer representing the amperage of the thre…
1.3.6.1.4.1.674.10892.5.4.600.30.1.12ColumnamperageProbeLowerNonCriticalThresholdread-onlycurrent0600.0030.0001.0012 This attribute defines the lower noncritical threshold of the amperage probe. The value is an integer representing the amperage of the thre…
1.3.6.1.4.1.674.10892.5.4.600.30.1.13ColumnamperageProbeLowerCriticalThresholdread-onlycurrent0600.0030.0001.0013 This attribute defines the lower critical threshold of the amperage probe. The value is an integer representing the amperage of the thresho…
1.3.6.1.4.1.674.10892.5.4.600.30.1.14ColumnamperageProbeLowerNonRecoverableThresholdread-onlycurrent0600.0030.0001.0014 This attribute defines the lower nonrecoverable threshold of the amperage probe. The value is an integer representing the amperage of the t…
1.3.6.1.4.1.674.10892.5.4.600.30.1.15ColumnamperageProbeProbeCapabilitiesread-onlycurrent0600.0030.0001.0015 This attribute defines the probe capabilities of the amperage probe.
1.3.6.1.4.1.674.10892.5.4.600.30.1.16ColumnamperageProbeDiscreteReadingread-onlycurrent0600.0030.0001.0016 This attribute defines the reading for an amperage probe of type amperageProbeTypeIsDiscrete. When the value for amperageProbeType is other…
1.3.6.1.4.1.674.10892.5.4.600.50TablesystemBatteryTablenot-accessiblecurrent0600.0050 This object defines the System Battery Table.
1.3.6.1.4.1.674.10892.5.4.600.50.1RowsystemBatteryTableEntrynot-accessiblecurrent0600.0050.0001 This object defines the System Battery Table Entry.
1.3.6.1.4.1.674.10892.5.4.600.50.1.1ColumnsystemBatteryChassisIndexread-onlycurrent0600.0050.0001.0001 This attribute defines the index (one based) of the system chassis that contains the battery.
1.3.6.1.4.1.674.10892.5.4.600.50.1.2ColumnsystemBatteryIndexread-onlycurrent0600.0050.0001.0002 This attribute defines the index (one based) of the battery.
1.3.6.1.4.1.674.10892.5.4.600.50.1.3ColumnsystemBatteryStateCapabilitiesread-onlycurrent0600.0050.0001.0003 This attribute defines the state capabilities of the battery.
1.3.6.1.4.1.674.10892.5.4.600.50.1.4ColumnsystemBatteryStateSettingsread-onlycurrent0600.0050.0001.0004 This attribute defines the state settings of the battery.
1.3.6.1.4.1.674.10892.5.4.600.50.1.5ColumnsystemBatteryStatusread-onlycurrent0600.0050.0001.0005 This attribute defines the status of the battery.
1.3.6.1.4.1.674.10892.5.4.600.50.1.6ColumnsystemBatteryReadingread-onlycurrent0600.0050.0001.0006 This attribute defines the reading of the battery.
1.3.6.1.4.1.674.10892.5.4.600.50.1.7ColumnsystemBatteryLocationNameread-onlycurrent0600.0050.0001.0007 This attribute defines the location of the battery.
1.3.6.1.4.1.674.10892.5.4.600.60TablepowerUsageTablenot-accessiblecurrent0600.0060 This object defines the Power Usage Table.
1.3.6.1.4.1.674.10892.5.4.600.60.1RowpowerUsageTableEntrynot-accessiblecurrent0600.0060.0001 This object defines the Power Usage Table Entry.
1.3.6.1.4.1.674.10892.5.4.600.60.1.1ColumnpowerUsageChassisIndexread-onlycurrent0600.0060.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.600.60.1.2ColumnpowerUsageIndexread-onlycurrent0600.0060.0001.0002 This attribute defines the index (one based) of the power usage information.
1.3.6.1.4.1.674.10892.5.4.600.60.1.3ColumnpowerUsageStateCapabilitiesread-onlycurrent0600.0060.0001.0003 This attribute defines the state capabilities of the power usage information.
1.3.6.1.4.1.674.10892.5.4.600.60.1.4ColumnpowerUsageStateSettingsread-onlycurrent0600.0060.0001.0004 This attribute defines the state settings of the power usage information.
1.3.6.1.4.1.674.10892.5.4.600.60.1.5ColumnpowerUsageStatusread-onlycurrent0600.0060.0001.0005 This attribute defines the status of the power usage information.
1.3.6.1.4.1.674.10892.5.4.600.60.1.6ColumnpowerUsageEntityNameread-onlycurrent0600.0060.0001.0006 This attribute defines the name of the entity associated with this power usage information.
1.3.6.1.4.1.674.10892.5.4.600.60.1.7ColumnpowerUsageCumulativeWattageread-onlycurrent0600.0060.0001.0007 This attribute defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeW…
1.3.6.1.4.1.674.10892.5.4.600.60.1.8ColumnpowerUsageCumulativeWattageStartDateNameread-onlycurrent0600.0060.0001.0008 This attribute defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage att…
1.3.6.1.4.1.674.10892.5.4.600.60.1.9ColumnpowerUsagePeakWattsread-onlycurrent0600.0060.0001.0009 This attribute defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStar…
1.3.6.1.4.1.674.10892.5.4.600.60.1.10ColumnpowerUsagePeakWattsStartDateNameread-onlycurrent0600.0060.0001.0010 This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute.
1.3.6.1.4.1.674.10892.5.4.600.60.1.11ColumnpowerUsagePeakWattsReadingDateNameread-onlycurrent0600.0060.0001.0011 This attribute defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured.
1.3.6.1.4.1.674.10892.5.4.600.60.1.12ColumnpowerUsagePeakAmpsread-onlycurrent0600.0060.0001.0012 This attribute defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePea…
1.3.6.1.4.1.674.10892.5.4.600.60.1.13ColumnpowerUsagePeakAmpsStartDateNameread-onlycurrent0600.0060.0001.0013 This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute.
1.3.6.1.4.1.674.10892.5.4.600.60.1.14ColumnpowerUsagePeakAmpsReadingDateNameread-onlycurrent0600.0060.0001.0014 This attribute defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured.
1.3.6.1.4.1.674.10892.5.4.600.60.1.15ColumnpowerUsageIdlePowerread-onlycurrent0600.0060.0001.0015 This attribute defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware con…
1.3.6.1.4.1.674.10892.5.4.600.60.1.16ColumnpowerUsageMaxPotentialPowerread-onlycurrent0600.0060.0001.0016 This attribute defines the system maximum potential power (in Watts). This is the maximum power the system can consume based on the current…
1.3.6.1.4.1.674.10892.5.4.600.60.1.17ColumnpowerUsagePowerCapCapabilitiesread-onlycurrent0600.0060.0001.0017 This attribute defines the system power cap capabilities.
1.3.6.1.4.1.674.10892.5.4.600.60.1.18ColumnpowerUsagePowerCapSettingread-onlycurrent0600.0060.0001.0018 This attribute defines the system power cap setting.
1.3.6.1.4.1.674.10892.5.4.600.60.1.19ColumnpowerUsagePowerCapValueread-onlycurrent0600.0060.0001.0019 This attribute defines the system power cap value (in Watts).
1.3.6.1.4.1.674.10892.5.4.600.60.1.20ColumnpowerUsageInstantaneousHeadroomread-onlycurrent0600.0060.0001.0020 This attribute defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus …
1.3.6.1.4.1.674.10892.5.4.600.60.1.21ColumnpowerUsagePeakHeadroomread-onlycurrent0600.0060.0001.0021 This attribute defines the system peak headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus peak powe…
1.3.6.1.4.1.674.10892.5.4.700NodethermalGroup
1.3.6.1.4.1.674.10892.5.4.700.10TablecoolingUnitTablenot-accessiblecurrent0700.0010 This object defines the Cooling Unit Table.
1.3.6.1.4.1.674.10892.5.4.700.10.1RowcoolingUnitTableEntrynot-accessiblecurrent0700.0010.0001 This object defines the Cooling Unit Table Entry.
1.3.6.1.4.1.674.10892.5.4.700.10.1.1ColumncoolingUnitchassisIndexread-onlycurrent0700.0010.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.700.10.1.2ColumncoolingUnitIndexread-onlycurrent0700.0010.0001.0002 This attribute defines the index (one based) of the cooling unit.
1.3.6.1.4.1.674.10892.5.4.700.10.1.3ColumncoolingUnitStateCapabiltiesread-onlycurrent0700.0010.0001.0003 This attribute defines the state capabilities of the cooling unit.
1.3.6.1.4.1.674.10892.5.4.700.10.1.4ColumncoolingUnitStateSettingsread-onlycurrent0700.0010.0001.0004 This attribute defines the state settings of the cooling unit.
1.3.6.1.4.1.674.10892.5.4.700.10.1.5ColumncoolingUnitRedundancyStatusread-onlycurrent0700.0010.0001.0005 This attribute defines the redundancy status of the cooling unit.
1.3.6.1.4.1.674.10892.5.4.700.10.1.6ColumncoolingDeviceCountForRedundancyread-onlycurrent0700.0010.0001.0006 This attribute defines the total number of cooling devices required for this cooling unit to have full redundancy.
1.3.6.1.4.1.674.10892.5.4.700.10.1.7ColumncoolingUnitNameread-onlycurrent0700.0010.0001.0007 This attribute defines the name of the cooling unit.
1.3.6.1.4.1.674.10892.5.4.700.10.1.8ColumncoolingUnitStatusread-onlycurrent0700.0010.0001.0008 This attribute defines the status of the cooling unit.
1.3.6.1.4.1.674.10892.5.4.700.12TablecoolingDeviceTablenot-accessiblecurrent0700.0012 This object defines the Cooling Device Table.
1.3.6.1.4.1.674.10892.5.4.700.12.1RowcoolingDeviceTableEntrynot-accessiblecurrent0700.0012.0001 This object defines the Cooling Device Table Entry.
1.3.6.1.4.1.674.10892.5.4.700.12.1.1ColumncoolingDevicechassisIndexread-onlycurrent0700.0012.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.700.12.1.2ColumncoolingDeviceIndexread-onlycurrent0700.0012.0001.0002 This attribute defines the index (one based) of the cooling device.
1.3.6.1.4.1.674.10892.5.4.700.12.1.3ColumncoolingDeviceStateCapabilitiesread-onlycurrent0700.0012.0001.0003 This attribute defines the state capabilities of the cooling device.
1.3.6.1.4.1.674.10892.5.4.700.12.1.4ColumncoolingDeviceStateSettingsread-onlycurrent0700.0012.0001.0004 This attribute defines the state settings of the cooling device.
1.3.6.1.4.1.674.10892.5.4.700.12.1.5ColumncoolingDeviceStatusread-onlycurrent0700.0012.0001.0005 This attribute defines the probe status of the cooling device.
1.3.6.1.4.1.674.10892.5.4.700.12.1.6ColumncoolingDeviceReadingread-onlycurrent0700.0012.0001.0006 This attribute defines the reading for a cooling device of subtype other than coolingDeviceSubTypeIsDiscrete. When the value for coolingDev…
1.3.6.1.4.1.674.10892.5.4.700.12.1.7ColumncoolingDeviceTyperead-onlycurrent0700.0012.0001.0007 This attribute defines the type of the cooling device.
1.3.6.1.4.1.674.10892.5.4.700.12.1.8ColumncoolingDeviceLocationNameread-onlycurrent0700.0012.0001.0008 This attribute defines the location name of the cooling device.
1.3.6.1.4.1.674.10892.5.4.700.12.1.9ColumncoolingDeviceUpperNonRecoverableThresholdread-onlycurrent0700.0012.0001.0009 This attribute defines the upper nonrecoverable threshold of the cooling device. The value is an integer representing fan speed in revoluti…
1.3.6.1.4.1.674.10892.5.4.700.12.1.10ColumncoolingDeviceUpperCriticalThresholdread-onlycurrent0700.0012.0001.0010 This attribute defines the upper critical threshold of the cooling device. The value is an integer representing fan speed in revolutions pe…
1.3.6.1.4.1.674.10892.5.4.700.12.1.11ColumncoolingDeviceUpperNonCriticalThresholdread-onlycurrent0700.0012.0001.0011 This attribute defines the upper noncritical threshold of the cooling device. The value is an integer representing fan speed in revolutions…
1.3.6.1.4.1.674.10892.5.4.700.12.1.12ColumncoolingDeviceLowerNonCriticalThresholdread-onlycurrent0700.0012.0001.0012 This attribute defines the lower noncritical threshold of the cooling device. The value is an integer representing fan speed in revolutions…
1.3.6.1.4.1.674.10892.5.4.700.12.1.13ColumncoolingDeviceLowerCriticalThresholdread-onlycurrent0700.0012.0001.0013 This attribute defines the lower critical threshold of the cooling device. The value is an integer representing fan speed in revolutions pe…
1.3.6.1.4.1.674.10892.5.4.700.12.1.14ColumncoolingDeviceLowerNonRecoverableThresholdread-onlycurrent0700.0012.0001.0014 This attribute defines the lower nonrecoverable threshold of the cooling device. The value is an integer representing fan speed in revoluti…
1.3.6.1.4.1.674.10892.5.4.700.12.1.15ColumncoolingDevicecoolingUnitIndexReferenceread-onlycurrent0700.0012.0001.0015 This attribute defines the index to the associated cooling unit.
1.3.6.1.4.1.674.10892.5.4.700.12.1.16ColumncoolingDeviceSubTyperead-onlycurrent0700.0012.0001.0016 This attribute defines the subtype of the cooling device.
1.3.6.1.4.1.674.10892.5.4.700.12.1.17ColumncoolingDeviceProbeCapabilitiesread-onlycurrent0700.0012.0001.0017 This attribute defines the probe capabilities of the cooling device.
1.3.6.1.4.1.674.10892.5.4.700.12.1.18ColumncoolingDeviceDiscreteReadingread-onlycurrent0700.0012.0001.0018 This attribute defines the reading for a cooling device of type coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is …
1.3.6.1.4.1.674.10892.5.4.700.12.1.19ColumncoolingDeviceFQDDread-onlycurrent0700.0012.0001.0019 Fully qualified device descriptor (FQDD) of the cooling device.
1.3.6.1.4.1.674.10892.5.4.700.20TabletemperatureProbeTablenot-accessiblecurrent0700.0020 This object defines the Temperature Probe Table.
1.3.6.1.4.1.674.10892.5.4.700.20.1RowtemperatureProbeTableEntrynot-accessiblecurrent0700.0020.0001 This object defines the Temperature Probe Table Entry.
1.3.6.1.4.1.674.10892.5.4.700.20.1.1ColumntemperatureProbechassisIndexread-onlycurrent0700.0020.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.700.20.1.2ColumntemperatureProbeIndexread-onlycurrent0700.0020.0001.0002 This attribute defines the index (one based) of the temperature probe.
1.3.6.1.4.1.674.10892.5.4.700.20.1.3ColumntemperatureProbeStateCapabilitiesread-onlycurrent0700.0020.0001.0003 This attribute defines the state capabilities of the temperature probe.
1.3.6.1.4.1.674.10892.5.4.700.20.1.4ColumntemperatureProbeStateSettingsread-onlycurrent0700.0020.0001.0004 This attribute defines the state settings of the temperature probe.
1.3.6.1.4.1.674.10892.5.4.700.20.1.5ColumntemperatureProbeStatusread-onlycurrent0700.0020.0001.0005 This attribute defines the probe status of the temperature probe.
1.3.6.1.4.1.674.10892.5.4.700.20.1.6ColumntemperatureProbeReadingread-onlycurrent0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatur…
1.3.6.1.4.1.674.10892.5.4.700.20.1.7ColumntemperatureProbeTyperead-onlycurrent0700.0020.0001.0007 This attribute defines the type of the temperature probe.
1.3.6.1.4.1.674.10892.5.4.700.20.1.8ColumntemperatureProbeLocationNameread-onlycurrent0700.0020.0001.0008 This attribute defines the location name of the temperature probe.
1.3.6.1.4.1.674.10892.5.4.700.20.1.9ColumntemperatureProbeUpperNonRecoverableThresholdread-onlycurrent0700.0020.0001.0009 This attribute defines the upper nonrecoverable threshold of the temperature probe. The value is an integer representing the temperature of…
1.3.6.1.4.1.674.10892.5.4.700.20.1.10ColumntemperatureProbeUpperCriticalThresholdread-onlycurrent0700.0020.0001.0010 This attribute defines the upper critical threshold of the temperature probe. The value is an integer representing the temperature of the t…
1.3.6.1.4.1.674.10892.5.4.700.20.1.11ColumntemperatureProbeUpperNonCriticalThresholdread-onlycurrent0700.0020.0001.0011 This attribute defines the upper noncritical threshold of the temperature probe. The value is an integer representing the temperature of th…
1.3.6.1.4.1.674.10892.5.4.700.20.1.12ColumntemperatureProbeLowerNonCriticalThresholdread-onlycurrent0700.0020.0001.0012 This attribute defines the lower noncritical threshold of the temperature probe. The value is an integer representing the temperature of th…
1.3.6.1.4.1.674.10892.5.4.700.20.1.13ColumntemperatureProbeLowerCriticalThresholdread-onlycurrent0700.0020.0001.0013 This attribute defines the lower critical threshold of the temperature probe. The value is an integer representing the temperature of the t…
1.3.6.1.4.1.674.10892.5.4.700.20.1.14ColumntemperatureProbeLowerNonRecoverableThresholdread-onlycurrent0700.0020.0001.0014 This attribute defines the lower nonrecoverable threshold of the temperature probe. The value is an integer representing the temperature of…
1.3.6.1.4.1.674.10892.5.4.700.20.1.15ColumntemperatureProbeProbeCapabilitiesread-onlycurrent0700.0020.0001.0015 This attribute defines the probe capabilities of the temperature probe.
1.3.6.1.4.1.674.10892.5.4.700.20.1.16ColumntemperatureProbeDiscreteReadingread-onlycurrent0700.0020.0001.0016 This attribute defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType …
1.3.6.1.4.1.674.10892.5.4.1100NodedeviceGroup
1.3.6.1.4.1.674.10892.5.4.1100.30TableprocessorDeviceTablenot-accessiblecurrent1100.0030 This object defines the Processor Device Table.
1.3.6.1.4.1.674.10892.5.4.1100.30.1RowprocessorDeviceTableEntrynot-accessiblecurrent1100.0030.0001 This object defines the Processor Device Table Entry.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.1ColumnprocessorDevicechassisIndexread-onlycurrent1100.0030.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.2ColumnprocessorDeviceIndexread-onlycurrent1100.0030.0001.0002 This attribute defines the index (one based) of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.3ColumnprocessorDeviceStateCapabilitiesread-onlycurrent1100.0030.0001.0003 This attribute defines the state capabilities of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.4ColumnprocessorDeviceStateSettingsread-onlycurrent1100.0030.0001.0004 This attribute defines the state settings of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.5ColumnprocessorDeviceStatusread-onlycurrent1100.0030.0001.0005 This attribute defines the status of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.7ColumnprocessorDeviceTyperead-onlycurrent1100.0030.0001.0007 This attribute defines the type of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.8ColumnprocessorDeviceManufacturerNameread-onlycurrent1100.0030.0001.0008 This attribute defines the name of the manufacturer of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.9ColumnprocessorDeviceStatusStateread-onlycurrent1100.0030.0001.0009 This attribute defines the status state of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.10ColumnprocessorDeviceFamilyread-onlycurrent1100.0030.0001.0010 This attribute defines the family of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.11ColumnprocessorDeviceMaximumSpeedread-onlycurrent1100.0030.0001.0011 This attribute defines the maximum speed of the processor device in MHz. Zero indicates the maximum speed is unknown.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.12ColumnprocessorDeviceCurrentSpeedread-onlycurrent1100.0030.0001.0012 This attribute defines the current speed of the processor device in MHz. Zero indicates the current speed is unknown.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.13ColumnprocessorDeviceExternalClockSpeedread-onlycurrent1100.0030.0001.0013 This attribute defines the speed of the external clock for the processor device in MHz. Zero indicates the external clock speed is unknown.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.14ColumnprocessorDeviceVoltageread-onlycurrent1100.0030.0001.0014 This attribute defines the voltage powering the processor device in millivolts. Zero indicates the voltage is unknown.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.16ColumnprocessorDeviceVersionNameread-onlycurrent1100.0030.0001.0016 This attribute defines the version of the processor device. On some systems, this value contains the brand and stepping information; on oth…
1.3.6.1.4.1.674.10892.5.4.1100.30.1.17ColumnprocessorDeviceCoreCountread-onlycurrent1100.0030.0001.0017 This attribute defines the number of processor cores detected for the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.18ColumnprocessorDeviceCoreEnabledCountread-onlycurrent1100.0030.0001.0018 This attribute defines the number of processor cores enabled for the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.19ColumnprocessorDeviceThreadCountread-onlycurrent1100.0030.0001.0019 This attribute defines the number of processor threads detected for the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.20ColumnprocessorDeviceCharacteristicsread-onlycurrent1100.0030.0001.0020 This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below whe…
1.3.6.1.4.1.674.10892.5.4.1100.30.1.21ColumnprocessorDeviceExtendedCapabilitiesread-onlycurrent1100.0030.0001.0021 This attribute defines extended capabilities of the processor device. This attribute is a bit field where a bit has the meaning defined bel…
1.3.6.1.4.1.674.10892.5.4.1100.30.1.22ColumnprocessorDeviceExtendedSettingsread-onlycurrent1100.0030.0001.0022 This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below w…
1.3.6.1.4.1.674.10892.5.4.1100.30.1.23ColumnprocessorDeviceBrandNameread-onlycurrent1100.0030.0001.0023 This attribute defines the brand of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.30.1.26ColumnprocessorDeviceFQDDread-onlycurrent1100.0030.0001.0026 Fully qualified device descriptor (FQDD) of the processor device.
1.3.6.1.4.1.674.10892.5.4.1100.32TableprocessorDeviceStatusTablenot-accessiblecurrent1100.0032 This object defines the Processor Device Status Table.
1.3.6.1.4.1.674.10892.5.4.1100.32.1RowprocessorDeviceStatusTableEntrynot-accessiblecurrent1100.0032.0001 This object defines the Processor Device Status Table Entry.
1.3.6.1.4.1.674.10892.5.4.1100.32.1.1ColumnprocessorDeviceStatusChassisIndexread-onlycurrent1100.0032.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.1100.32.1.2ColumnprocessorDeviceStatusIndexread-onlycurrent1100.0032.0001.0002 This attribute defines the index (one based) of the processor device status probe.
1.3.6.1.4.1.674.10892.5.4.1100.32.1.3ColumnprocessorDeviceStatusStateCapabilitiesread-onlycurrent1100.0032.0001.0003 This attribute defines the state capabilities of the processor device status probe.
1.3.6.1.4.1.674.10892.5.4.1100.32.1.4ColumnprocessorDeviceStatusStateSettingsread-onlycurrent1100.0032.0001.0004 This attribute defines the state settings of the processor device status probe.
1.3.6.1.4.1.674.10892.5.4.1100.32.1.5ColumnprocessorDeviceStatusStatusread-onlycurrent1100.0032.0001.0005 This attribute defines the status of the processor device status probe. This status will be joined into the processorDeviceStatus attribute.
1.3.6.1.4.1.674.10892.5.4.1100.32.1.6ColumnprocessorDeviceStatusReadingread-onlycurrent1100.0032.0001.0006 This attribute defines the reading of the processor device status probe.
1.3.6.1.4.1.674.10892.5.4.1100.32.1.7ColumnprocessorDeviceStatusLocationNameread-onlycurrent1100.0032.0001.0007 This attribute defines the location name of the processor device status probe.
1.3.6.1.4.1.674.10892.5.4.1100.50TablememoryDeviceTablenot-accessiblecurrent1100.0050 This object defines the Memory Device Table.
1.3.6.1.4.1.674.10892.5.4.1100.50.1RowmemoryDeviceTableEntrynot-accessiblecurrent1100.0050.0001 This object defines the Memory Device Table Entry.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.1ColumnmemoryDevicechassisIndexread-onlycurrent1100.0050.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.2ColumnmemoryDeviceIndexread-onlycurrent1100.0050.0001.0002 This attribute defines the index (one based) of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.3ColumnmemoryDeviceStateCapabilitiesread-onlycurrent1100.0050.0001.0003 This attribute defines the state capabilities of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.4ColumnmemoryDeviceStateSettingsread-onlycurrent1100.0050.0001.0004 This attribute defines the state settings of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.5ColumnmemoryDeviceStatusread-onlycurrent1100.0050.0001.0005 This attribute defines the status of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.7ColumnmemoryDeviceTyperead-onlycurrent1100.0050.0001.0007 This attribute defines the type of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.8ColumnmemoryDeviceLocationNameread-onlycurrent1100.0050.0001.0008 This attribute defines the location of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.10ColumnmemoryDeviceBankLocationNameread-onlycurrent1100.0050.0001.0010 This attribute defines the location of the bank for the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.14ColumnmemoryDeviceSizeread-onlycurrent1100.0050.0001.0014 This attribute defines the size in KBytes of the memory device. Zero indicates no memory installed; 2,147,483,647 indicates an unknown memo…
1.3.6.1.4.1.674.10892.5.4.1100.50.1.15ColumnmemoryDeviceSpeedread-onlycurrent1100.0050.0001.0015 This attribute defines the maximum capable speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.21ColumnmemoryDeviceManufacturerNameread-onlycurrent1100.0050.0001.0021 This attribute defines the manufacturer of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.22ColumnmemoryDevicePartNumberNameread-onlycurrent1100.0050.0001.0022 This attribute defines the manufacturer's part number for the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.23ColumnmemoryDeviceSerialNumberNameread-onlycurrent1100.0050.0001.0023 This attribute defines the serial number of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.26ColumnmemoryDeviceFQDDread-onlycurrent1100.0050.0001.0026 Fully qualified device descriptor (FQDD) of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.27ColumnmemoryDeviceCurrentOperatingSpeedread-onlycurrent1100.0050.0001.0027 This attribute defines the current operating speed in megahertz (MHz) of the memory device. Zero indicates an unknown speed.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.28ColumnmemoryDeviceTechnologyread-onlycurrent1100.0050.0001.0028 This attribute defines the type or technology of the memory device.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.29ColumnmemoryDeviceVolatileSizeread-onlycurrent1100.0050.0001.0029 This attribute defines the volatile size of the memory device in MBs.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.30ColumnmemoryDeviceNonVolatilesSizeread-onlycurrent1100.0050.0001.0030 This attribute defines the Non Volatile size of the memory device in MBs.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.31ColumnmemoryDeviceCacheSizeread-onlycurrent1100.0050.0001.0031 This attribute defines the Cache size of the memory device in MBs.
1.3.6.1.4.1.674.10892.5.4.1100.50.1.32ColumnmemoryDeviceRemainingRatedWriteEnduranceread-onlycurrent1100.0050.0001.0032 This attribute defines the percent of remaining life for the memory device
1.3.6.1.4.1.674.10892.5.4.1100.80TablepCIDeviceTablenot-accessiblecurrent1100.0080 This object defines the PCI Device Table.
1.3.6.1.4.1.674.10892.5.4.1100.80.1RowpCIDeviceTableEntrynot-accessiblecurrent1100.0080.0001 This object defines the PCI Device Table Entry.
1.3.6.1.4.1.674.10892.5.4.1100.80.1.1ColumnpCIDevicechassisIndexread-onlycurrent1100.0080.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.1100.80.1.2ColumnpCIDeviceIndexread-onlycurrent1100.0080.0001.0002 This attribute defines the index (one based) of the PCI device.
1.3.6.1.4.1.674.10892.5.4.1100.80.1.3ColumnpCIDeviceStateCapabilitiesread-onlycurrent1100.0080.0001.0003 This attribute defines the state capabilities of the PCI device.
1.3.6.1.4.1.674.10892.5.4.1100.80.1.4ColumnpCIDeviceStateSettingsread-onlycurrent1100.0080.0001.0004 This attribute defines the state settings of the PCI device.
1.3.6.1.4.1.674.10892.5.4.1100.80.1.5ColumnpCIDeviceStatusread-onlycurrent1100.0080.0001.0005 This attribute defines the status of the PCI device.
1.3.6.1.4.1.674.10892.5.4.1100.80.1.7ColumnpCIDeviceDataBusWidthread-onlycurrent1100.0080.0001.0007 This attribute defines the width of the data bus of the PCI device. This attribute contains an enumeration value. The possible values and t…
1.3.6.1.4.1.674.10892.5.4.1100.80.1.8ColumnpCIDeviceManufacturerNameread-onlycurrent1100.0080.0001.0008 This attribute defines the name of the manufacturer of the PCI device.
1.3.6.1.4.1.674.10892.5.4.1100.80.1.9ColumnpCIDeviceDescriptionNameread-onlycurrent1100.0080.0001.0009 This attribute defines the description of the PCI device.
1.3.6.1.4.1.674.10892.5.4.1100.80.1.12ColumnpCIDeviceFQDDread-onlycurrent1100.0080.0001.0012 Fully qualified device descriptor (FQDD) of the PCI device.
1.3.6.1.4.1.674.10892.5.4.1100.90TablenetworkDeviceTablenot-accessiblecurrent1100.0090 This object defines the Network Device Table.
1.3.6.1.4.1.674.10892.5.4.1100.90.1RownetworkDeviceTableEntrynot-accessiblecurrent1100.0090.0001 This object defines the Network Device Table Entry.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.1ColumnnetworkDeviceChassisIndexread-onlycurrent1100.0090.0001.0001 This attribute defines the index (one based) of the system chassis that contains the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.2ColumnnetworkDeviceIndexread-onlycurrent1100.0090.0001.0002 This attribute defines the index (one based) of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.3ColumnnetworkDeviceStatusread-onlycurrent1100.0090.0001.0003 This attribute defines the status of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.4ColumnnetworkDeviceConnectionStatusread-onlycurrent1100.0090.0001.0004 This attribute defines the connection status of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.6ColumnnetworkDeviceProductNameread-onlycurrent1100.0090.0001.0006 This attribute defines the product name of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.7ColumnnetworkDeviceVendorNameread-onlycurrent1100.0090.0001.0007 This attribute defines the name of the vendor of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.15ColumnnetworkDeviceCurrentMACAddressread-onlycurrent1100.0090.0001.0015 This attribute defines the current MAC address of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.16ColumnnetworkDevicePermanentMACAddressread-onlycurrent1100.0090.0001.0016 This attribute defines the permanent MAC address of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.17ColumnnetworkDevicePCIBusNumberread-onlycurrent1100.0090.0001.0017 This attribute defines the PCI bus number of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.18ColumnnetworkDevicePCIDeviceNumberread-onlycurrent1100.0090.0001.0018 This attribute defines the PCI device number of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.19ColumnnetworkDevicePCIFunctionNumberread-onlycurrent1100.0090.0001.0019 This attribute defines the PCI function number of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.23ColumnnetworkDeviceTOECapabilityFlagsread-onlycurrent1100.0090.0001.0023 This attribute defines the TCP/IP Offload Engine (TOE) capability flags of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.27ColumnnetworkDeviceiSCSICapabilityFlagsread-onlycurrent1100.0090.0001.0027 This attribute defines the Internet Small Computer System Interface (iSCSI) capability flags of the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.28ColumnnetworkDeviceiSCSIEnabledread-onlycurrent1100.0090.0001.0028 This attribute defines if iSCSI is enabled for the network device.
1.3.6.1.4.1.674.10892.5.4.1100.90.1.29ColumnnetworkDeviceCapabilitiesread-onlycurrent1100.0090.0001.0029 This attribute defines the capabilities of the network device. If this value is notSupported(0), the networkDeviceTOECapabilityFlags, netwo…
1.3.6.1.4.1.674.10892.5.4.1100.90.1.30ColumnnetworkDeviceFQDDread-onlycurrent1100.0090.0001.0030 Fully qualified device descriptor (FQDD) of the network device.
1.3.6.1.4.1.674.10892.5.4.1200NodeslotGroup
1.3.6.1.4.1.674.10892.5.4.1200.10TablesystemSlotTablenot-accessiblecurrent1200.0010 This object defines the System Slot Table.
1.3.6.1.4.1.674.10892.5.4.1200.10.1RowsystemSlotTableEntrynot-accessiblecurrent1200.0010.0001 This object defines the System Slot Table Entry.
1.3.6.1.4.1.674.10892.5.4.1200.10.1.1ColumnsystemSlotchassisIndexread-onlycurrent1200.0010.0001.0001 This attribute defines the index (one based) of the associated system chassis.
1.3.6.1.4.1.674.10892.5.4.1200.10.1.2ColumnsystemSlotIndexread-onlycurrent1200.0010.0001.0002 This attribute defines the index (one based) of the system slot.
1.3.6.1.4.1.674.10892.5.4.1200.10.1.3ColumnsystemSlotStateCapabilitiesUniqueread-onlycurrent1200.0010.0001.0003 This attribute defines the state capabilities of the system slot.
1.3.6.1.4.1.674.10892.5.4.1200.10.1.4ColumnsystemSlotStateSettingsUniqueread-onlycurrent1200.0010.0001.0004 This attribute defines the state settings of the system slot.
1.3.6.1.4.1.674.10892.5.4.1200.10.1.5ColumnsystemSlotStatusread-onlycurrent1200.0010.0001.0005 This attribute defines the status of the system slot.
1.3.6.1.4.1.674.10892.5.4.1200.10.1.6ColumnsystemSlotCurrentUsageread-onlycurrent1200.0010.0001.0006 This attribute defines the current usage of the system slot.
1.3.6.1.4.1.674.10892.5.4.1200.10.1.7ColumnsystemSlotTyperead-onlycurrent1200.0010.0001.0007 This attribute defines the type of the system slot.
1.3.6.1.4.1.674.10892.5.4.1200.10.1.8ColumnsystemSlotSlotExternalSlotNameread-onlycurrent1200.0010.0001.0008 This attribute defines the name of the external connector name of the system slot.
1.3.6.1.4.1.674.10892.5.4.1200.10.1.11ColumnsystemSlotCategoryread-onlycurrent1200.0010.0001.0011 This attribute defines the category of the system slot.
1.3.6.1.4.1.674.10892.5.4.2000NodefruGroup
1.3.6.1.4.1.674.10892.5.4.2000.10TablefruTablenot-accessiblecurrent2000.0010 This object defines the Field Replaceable Unit table.
1.3.6.1.4.1.674.10892.5.4.2000.10.1RowfruTableEntrynot-accessiblecurrent2000.0010.0001 This object defines the Field Replaceable Unit table entry.
1.3.6.1.4.1.674.10892.5.4.2000.10.1.1ColumnfruChassisIndexread-onlycurrent2000.0010.0001.0001 This attribute defines the index (one based) of the system chassis containing the field replaceable unit.
1.3.6.1.4.1.674.10892.5.4.2000.10.1.2ColumnfruIndexread-onlycurrent2000.0010.0001.0002 This attribute defines the index (one based) of the field replaceable unit.
1.3.6.1.4.1.674.10892.5.4.2000.10.1.3ColumnfruInformationStatusread-onlycurrent2000.0010.0001.0003 This attribute defines the status of the field replaceable unit information.
1.3.6.1.4.1.674.10892.5.4.2000.10.1.6ColumnfruManufacturerNameread-onlycurrent2000.0010.0001.0006 This attribute defines the manufacturer of the field replaceable unit.
1.3.6.1.4.1.674.10892.5.4.2000.10.1.7ColumnfruSerialNumberNameread-onlycurrent2000.0010.0001.0007 This attribute defines the serial number of the field replaceable unit.
1.3.6.1.4.1.674.10892.5.4.2000.10.1.8ColumnfruPartNumberNameread-onlycurrent2000.0010.0001.0008 This attribute defines the part number of the field replaceable unit.
1.3.6.1.4.1.674.10892.5.4.2000.10.1.9ColumnfruRevisionNameread-onlycurrent2000.0010.0001.0009 This attribute defines the revision of the field replaceable unit.
1.3.6.1.4.1.674.10892.5.4.2000.10.1.12ColumnfruFQDDread-onlycurrent2000.0010.0001.0012 Fully qualified device descriptor (FQDD) of the field replaceable unit.
1.3.6.1.4.1.674.10892.5.5NodestorageDetailsGroup
1.3.6.1.4.1.674.10892.5.5.1Nodesoftware
1.3.6.1.4.1.674.10892.5.5.1.20NodestorageManagement
1.3.6.1.4.1.674.10892.5.5.1.20.130NodephysicalDevices
1.3.6.1.4.1.674.10892.5.5.1.20.130.1TablecontrollerTablenot-accessiblecurrentA table of managed RAID controllers. The number of entries is related to number of RAID controllers discovered in the system. The maximum number of entries is …
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1RowcontrollerTableEntrynot-accessiblecurrentAn entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.1ColumncontrollerNumberread-onlycurrentInstance number of this controller entry.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2ColumncontrollerNameread-onlycurrentThe controller's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.7ColumncontrollerRebuildRateread-onlycurrentThe rebuild rate is the percentage of the controller's resources dedicated to rebuilding a failed disk when a rebuild is necessary.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8ColumncontrollerFWVersionread-onlycurrentThe controller's current firmware version.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.9ColumncontrollerCacheSizeInMBread-onlycurrentThe controller's current amount of cache memory in megabytes.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37ColumncontrollerRollUpStatusread-onlycurrentSeverity of the controller state. This is the combined status of the controller and its components. Possible values: 1: Other. 2: Unknown. 3: OK 4: Non-critica…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.38ColumncontrollerComponentStatusread-onlycurrentThe status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Cr…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41ColumncontrollerDriverVersionread-onlycurrentCurrently installed driver version for this controller on the host.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.42ColumncontrollerPCISlotread-onlycurrentThe PCI slot on the server where the controller is seated. This data is not reported for embedded or integrated controllers,
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.48ColumncontrollerReconstructRateread-onlycurrentThe reconstruct rate is the percentage of the controller's resources dedicated to reconstructing a disk group after adding a physical disk or changing the RAID…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.49ColumncontrollerPatrolReadRateread-onlycurrentThe patrol read rate is the percentage of the controller's resources dedicated to perform a patrol read on disks participating in a virtual disk or hot spares.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.50ColumncontrollerBGIRateread-onlycurrentThe background initialization (BGI) rate is the percentage of the controller's resources dedicated to performing the background initialization of a redundant v…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.51ColumncontrollerCheckConsistencyRateread-onlycurrentThe check consistency rate is the percentage of the controller's resources dedicated to performing a check consistency on a redundant virtual disk.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.52ColumncontrollerPatrolReadModeread-onlycurrentIdentifies the patrol read mode setting for the controller. Possible values: 1: Not one of the following or could not be determined. 2: Not Supported on this c…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.53ColumncontrollerPatrolReadStateread-onlycurrentThis property displays the current state of the patrol read process. Possible values: 1: Not one of the following or could not be determined. 2: Patrol read is…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.59ColumncontrollerPersistentHotSpareread-onlycurrentIndicates whether hot spare drives would be restored on insertion into the same slot.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.60ColumncontrollerSpinDownUnconfiguredDrivesread-onlycurrentIndicates whether un-configured drives would be put in power save mode by the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.61ColumncontrollerSpinDownHotSpareDrivesread-onlycurrentIndicates whether hot spare drives would be put in power save mode by the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.62ColumncontrollerSpinDownTimeIntervalread-onlycurrentThe duration in minutes after which, the unconfigured or hot spare drives will be spun down to power save mode.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.69ColumncontrollerPreservedCacheread-onlycurrentIndicates whether preserved cache or pinned cache is present on the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.70ColumncontrollerCheckConsistencyModeread-onlycurrentThe current check consistency mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Normal che…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.71ColumncontrollerCopyBackModeread-onlycurrentThe current copy back mode setting for the controller. Possible values: 1: Not one of the following. 2: Not supported on this controller. 3: Disks assigned as …
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.72ColumncontrollerSecurityStatusread-onlycurrentThe controller's current security/encryption status.. Possible values: 1: The current status could not be determined. 2: Controller is not operating in an encr…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.73ColumncontrollerEncryptionKeyPresentread-onlycurrentIndicates whether encryption key is assigned for the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.74ColumncontrollerEncryptionCapabilityread-onlycurrentThe type of encryption supported by the controller. Possible values: 1: Not one of the following. 2: No encryption supported, 3: Local Key Management,
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.75ColumncontrollerLoadBalanceSettingread-onlycurrentThe ability of the controller to automatically use both controller ports (or connectors) connected to the same enclosure in order to route I/O requests. Possib…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.76ColumncontrollerMaxCapSpeedread-onlycurrentThe maximum speed of the controller.in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 Gbps 4: 6.0 Gbps 5:…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.77ColumncontrollerSASAddressread-onlycurrentThe SAS address of the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.78ColumncontrollerFQDDread-onlycurrentThe controller's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79ColumncontrollerDisplayNameread-onlycurrentThe controller's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.80ColumncontrollerT10PICapabilityread-onlycurrentIndicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible value…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.81ColumncontrollerRAID10UnevenSpansSupportedread-onlycurrentIndicates whether uneven spans for RAID 10 virtual disk is supported on the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.82ColumncontrollerEnhancedAutoImportForeignConfigModeread-onlycurrentIndicates the status of enhanced auto-import of foreign configuration property of the controller. 1: Not one of the following. 2: Not Supported. 3: Disabled. 4…
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.83ColumncontrollerBootModeSupportedread-onlycurrentIndicates whether headless boot mode settings are supported on the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.84ColumncontrollerBootModeread-onlycurrentIndicates the boot mode of the controller. Possible values: 1: Not applicable for this controller. 2: User mode: User interaction required for all boot message…
1.3.6.1.4.1.674.10892.5.5.1.20.130.3TableenclosureTablenot-accessiblecurrentA table of managed enclosures/backplanes. The number of entries is related to number of internal backplane(s) discovered in the system and external storage enc…
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1RowenclosureTableEntrynot-accessiblecurrentAn entry in the enclosure table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.1ColumnenclosureNumberread-onlycurrentInstance number of this enclossre/backplane.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.2ColumnenclosureNameread-onlycurrentThe enclosure/backplane's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.4ColumnenclosureStateread-onlycurrentThe current state of this enclosure/backplane. Possible states: 1: The current state could not be determined. 2: The enclosure is operating normally. 3: The en…
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.8ColumnenclosureServiceTagread-onlycurrentEnclosure identification used when consulting customer support.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.9ColumnenclosureAssetTagread-onlycurrentThe asset tag information for the enclosure.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.19ColumnenclosureConnectedPortread-onlycurrentThe port on the controller to which the storage enclosure is connected.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.23ColumnenclosureRollUpStatusread-onlycurrentSeverity of the enclosure/backplane state. This is the combined status of the enclosure and its sub-components. Possible values: 1: Other. 2: Unknown. 3: OK. 4…
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.24ColumnenclosureComponentStatusread-onlycurrentThe status of the enclosure/backplane.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-cr…
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.26ColumnenclosureFirmwareVersionread-onlycurrentThe firmware information for the enclosure/backplane.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.30ColumnenclosureSASAddressread-onlycurrentThe SAS address of the enclosure/backplane.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.31ColumnenclosureDriveCountread-onlycurrentThe number of disks present in the enclosure/backplane.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.32ColumnenclosureTotalSlotsread-onlycurrentThe total physical drive slots in a storage enclosure or server backplane.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.40ColumnenclosureFanCountread-onlycurrentThe number of fans present in the storage enclosure.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.41ColumnenclosurePSUCountread-onlycurrentThe number of Power Supply Units (PSU) present in the storage enclosure.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.42ColumnenclosureEMMCountread-onlycurrentThe number of Enclosure Management Modules (EMM) present in the storage enclosure.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.43ColumnenclosureTempProbeCountread-onlycurrentThe number of temperature sensing devices present in the storage enclosure.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.44ColumnenclosureRedundantPathread-onlycurrentIndicates whether the controller has multiply paths to reach the storage enclosure.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.45ColumnenclosurePositionread-onlycurrentThe possition of the storage enclosure within a daisy chain.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.46ColumnenclosureBackplaneBayIDread-onlycurrentThe unique bay ID of the backplane.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.47ColumnenclosureFQDDread-onlycurrentThe enclosure/backplane's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.48ColumnenclosureDisplayNameread-onlycurrentThe enclosure/backplane's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.49ColumnenclosureTyperead-onlycurrentThe protocol supported by the backplane. Possible states: 1: Not one of the following or could not be determined. 2: Not applicable (i.e. object is not a backp…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4TablephysicalDiskTablenot-accessiblecurrentA table of managed physical disks. The number of entries is related to number of physical Disks discovered in the system. The maximum number of entries is impl…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1RowphysicalDiskTableEntrynot-accessiblecurrentAn entry in the physical Disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1ColumnphysicalDiskNumberread-onlycurrentInstance number of this physical disk entry.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2ColumnphysicalDiskNameread-onlycurrentThe physical disk's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.3ColumnphysicalDiskManufacturerread-onlycurrentThe name of the physical disk's manufacturer.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4ColumnphysicalDiskStateread-onlycurrentThe current state of this physical disk. Possible states: 1: The current state could not be determined. 2: The physical disk is available for use, but no RAID …
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6ColumnphysicalDiskProductIDread-onlycurrentThe model number of the physical disk.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7ColumnphysicalDiskSerialNoread-onlycurrentThe physical disk's unique identification number from the manufacturer.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.8ColumnphysicalDiskRevisionread-onlycurrentThe firmware version of the physical disk.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11ColumnphysicalDiskCapacityInMBread-onlycurrentThe size of the physical disk in megabytes.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.17ColumnphysicalDiskUsedSpaceInMBread-onlycurrentThe amount of used space in megabytes on the physical disk. This is not applicable for NVMe devices.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.19ColumnphysicalDiskFreeSpaceInMBread-onlycurrentThe amount of free space in megabytes on the physical disk. This is not applicable for NVMe devices.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.21ColumnphysicalDiskBusTyperead-onlycurrentThe bus type of the physical disk. Possible values: 1: The bus type could not be determined. 2: Small Computer System Interface (SCSI). 3: Serial Attached SCSI…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.22ColumnphysicalDiskSpareStateread-onlycurrentThe status of the disk as a spare. Possible values: 1: Physical disk is not a spare. 2: Physical disk is a dedicated hot spare. 3: Physical disk is a global ho…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.24ColumnphysicalDiskComponentStatusread-onlycurrentThe status of the physical disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5:…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.27ColumnphysicalDiskPartNumberread-onlycurrentThe part number of the disk.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.28ColumnphysicalDiskSASAddressread-onlycurrentThe SAS address of the physical disk.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.29ColumnphysicalDiskNegotiatedSpeedread-onlycurrentThe data transfer speed that the disk negotiated while spinning up in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 …
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.30ColumnphysicalDiskCapableSpeedread-onlycurrentThe maximum data transfer speed supported by the disk in Gigbits per second (Gbps). Possible values: 1: The speed could not be determined. 2. 1.5 Gbps 3: 3.0 G…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31ColumnphysicalDiskSmartAlertIndicationread-onlycurrentIndicates whether the physical disk has received a predictive failure alert.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.32ColumnphysicalDiskManufactureDayread-onlycurrentThe day of the week (1=Sunday thru 7=Saturday) on which the physical disk was manufactured.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.33ColumnphysicalDiskManufactureWeekread-onlycurrentThe week (1 thru 53) in which the physical disk was manufactured.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.34ColumnphysicalDiskManufactureYearread-onlycurrentThe four digit year in which the physical disk was manufactured.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.35ColumnphysicalDiskMediaTyperead-onlycurrentThe media type of the physical disk. Possible Values: 1: The media type could not be determined. 2: Hard Disk Drive (HDD). 3: Solid State Device (SSD).
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.42ColumnphysicalDiskPowerStateread-onlycurrentThe power state of the physical disk. Possible Values: 1: Not one of the following. 2: The physical disk is in the spun up state. 3: The physical disk is in th…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.49ColumnphysicalDiskRemainingRatedWriteEnduranceread-onlycurrentThis property is applicable to SSD media type only. This indicates the wear-out percentage of the SSD. Typically it is a value between 0 to 100. However, if th…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.50ColumnphysicalDiskOperationalStateread-onlycurrentThe state of the physical disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: Data from a redundan…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.51ColumnphysicalDiskProgressread-onlycurrentThe progress percentage of the operation that is being performed on the physical disk. This is applicable only if there is a progressive operations ongoing
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.52ColumnphysicalDiskSecurityStatusread-onlycurrentThe security/encryption status of the physical disk. Possible Values: 1: The physical disk supports encryption. 2: The physical disk does not support encryptio…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.53ColumnphysicalDiskFormFactorread-onlycurrentThe form factor of the physical disk. Possible values: 1: The form factor could not be determined. 2: 1.8 inch. 3: 2.5 inch. 4: 3.5 inch. 5: EDSFFE1.L.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.54ColumnphysicalDiskFQDDread-onlycurrentThe physical disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55ColumnphysicalDiskDisplayNameread-onlycurrentThe physical disk's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.57ColumnphysicalDiskT10PICapabilityread-onlycurrentIndicates whether the physical disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible va…
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.58ColumnphysicalDiskBlockSizeInBytesread-onlycurrentThe block size (in bytes) of the physical disk. This is not applicable for NVMe devices. 1: 512. 2: 4096
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.59ColumnphysicalDiskProtocolVersionread-onlycurrentApplicable for NVMe devices only. The NVMe protocol version supported by the device.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.60ColumnphysicalDiskPCIeNegotiatedLinkWidthread-onlycurrentApplicable for NVMe devices only. The PCIe link width negotiated with the host during device initialization.
1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.61ColumnphysicalDiskPCIeCapableLinkWidthread-onlycurrentApplicable for NVMe devices only. The PCIe link widths the device is capable of supporting.
1.3.6.1.4.1.674.10892.5.5.1.20.130.7TableenclosureFanTablenot-accessiblecurrentA table of managed fans in the external storage enclosure(s). The number of entries is related to number of fans discovered in the enclosure(s). The maximum nu…
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1RowenclosureFanTableEntrynot-accessiblecurrentAn entry in the fan table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.1ColumnenclosureFanNumberread-onlycurrentInstance number of this fan.
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.2ColumnenclosureFanNameread-onlycurrentThe fan's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.4ColumnenclosureFanStateread-onlycurrentThe current state of this fan. Possible states: 1: The current state could not be determined. 2: The fan is operating normally. 3: The fan has encountered a ha…
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.11ColumnenclosureFanSpeedread-onlycurrentIndicates the current relative speed of the fan.
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.15ColumnenclosureFanComponentStatusread-onlycurrentThe status of the fan itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical . 5: Crit…
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.20ColumnenclosureFanFQDDread-onlycurrentThe fan's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.21ColumnenclosureFanDisplayNameread-onlycurrentThe fan's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9TableenclosurePowerSupplyTablenot-accessiblecurrentA table of managed Power Supply Units(PSU) in the external storage enclosure(s). The number of entries is related to number of power supply unit(s) discovered …
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1RowenclosurePowerSupplyTableEntrynot-accessiblecurrentAn entry in the power supply unit table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1ColumnenclosurePowerSupplyNumberread-onlycurrentInstance number of this power supply unit.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2ColumnenclosurePowerSupplyNameread-onlycurrentThe power supply unit's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4ColumnenclosurePowerSupplyStateread-onlycurrentThe current state of this power supply unit. Possible states: 1: The current state could not be determined. 2: The power supply unit is operating normally. 3: …
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7ColumnenclosurePowerSupplyPartNumberread-onlycurrentThe part number of the power supply unit.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9ColumnenclosurePowerSupplyComponentStatusread-onlycurrentThe status of the power supply unit itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-crit…
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15ColumnenclosurePowerSupplyFQDDread-onlycurrentThe power supply unit's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.16ColumnenclosurePowerSupplyDisplayNameread-onlycurrentThe power supply unit's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11TableenclosureTemperatureProbeTablenot-accessiblecurrentA table of managed temperature probes in the external storage enclosure(s). The number of entries is related to number of temperature probes discovered in the …
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1RowenclosureTemperatureProbeTableEntrynot-accessiblecurrentAn entry in the temperature probe table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.1ColumnenclosureTemperatureProbeNumberread-onlycurrentInstance number of this temperature probe.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.2ColumnenclosureTemperatureProbeNameread-onlycurrentThe temperature probe's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.4ColumnenclosureTemperatureProbeStateread-onlycurrentThe current state of this temperature probe. Possible states: 1: The current state could not be determined. 2: The temperature probe is operating normally. 3: …
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.7ColumnenclosureTemperatureProbeMinWarningValueread-onlycurrentThe minimum temperature that will force the probe into a warning state.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.8ColumnenclosureTemperatureProbeMinCriticalValueread-onlycurrentThe minimum temperature that will force the probe into a error state.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.9ColumnenclosureTemperatureProbeMaxWarningValueread-onlycurrentThe maximum temperature that will force the probe into a warning state.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.10ColumnenclosureTemperatureProbeMaxCriticalValueread-onlycurrentThe maximum temperature that will force the probe into a warning state.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.11ColumnenclosureTemperatureProbeCurValueread-onlycurrentThe maximum temperature that will force the probe into a warning state.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.13ColumnenclosureTemperatureProbeComponentStatusread-onlycurrentThe status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4…
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.15ColumnenclosureTemperatureProbeFQDDread-onlycurrentThe temperature probe's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.16ColumnenclosureTemperatureProbeDisplayNameread-onlycurrentThe temperature probe's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.13TableenclosureManagementModuleTablenot-accessiblecurrentA table of managed Enclosure Management Modules (EMM) in the external storage enclosure(s). The number of entries is related to number of enclosure management …
1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1RowenclosureManagementModuleTableEntrynot-accessiblecurrentAn entry in the enclosure management module table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.1ColumnenclosureManagementModuleNumberread-onlycurrentInstance number of this enclosure management module.
1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.2ColumnenclosureManagementModuleNameread-onlycurrentThe enclosure management module's name as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.4ColumnenclosureManagementModuleStateread-onlycurrentThe current state of this enclosure management module. Possible states: 1: The current state could not be determined. 2: The enclosure management module is ope…
1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.6ColumnenclosureManagementModulePartNumberread-onlycurrentThe part number of the enclosure management module.
1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.8ColumnenclosureManagementModuleFWVersionread-onlycurrentFirmware version of the enclosure management module.
1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.11ColumnenclosureManagementModuleComponentStatusread-onlycurrentThe status of the enclosure management module.itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4…
1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.15ColumnenclosureManagementModuleFQDDread-onlycurrentThe enclosure management module's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.16ColumnenclosureManagementModuleDisplayNameread-onlycurrentThe enclosure management module's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.15TablebatteryTablenot-accessiblecurrentA table of managed batteries. The number of entries is related to number of Batteries discovered in the system. The maximum number of entries is implementation…
1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1RowbatteryTableEntrynot-accessiblecurrentAn entry in the battery table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1ColumnbatteryNumberread-onlycurrentInstance number of this battery entry.
1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4ColumnbatteryStateread-onlycurrentCurrent state of battery. Possible values: 1: The current state could not be determined. 2: The battery is operating normally. 3: The battery has failed and ne…
1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.6ColumnbatteryComponentStatusread-onlycurrentThe status of the battery itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Criti…
1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.10ColumnbatteryPredictedCapacityread-onlyobsoleteThis entry is obsolete. Use the batteryComponentStatus or batteryState instead.
1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20ColumnbatteryFQDDread-onlycurrentThe battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21ColumnbatteryDisplayNameread-onlycurrentThe battery's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.140NodelogicalDevices
1.3.6.1.4.1.674.10892.5.5.1.20.140.1TablevirtualDiskTablenot-accessiblecurrentA table of managed virtual disks. The number of entries is related to number of virtual disks discovered in the system. The maximum number of entries is implem…
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1RowvirtualDiskTableEntrynot-accessiblecurrentAn entry in the virtual disk table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1ColumnvirtualDiskNumberread-onlycurrentInstance number of this virtual disk entry.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2ColumnvirtualDiskNameread-onlycurrentThe virtual disk's label as entered by the user.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4ColumnvirtualDiskStateread-onlycurrentThe current state of this virtual disk (which includes any member physical disks.) Possible states: 1: The current state could not be determined. 2: The virtua…
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6ColumnvirtualDiskSizeInMBread-onlycurrentThe size of the virtual disk in megabytes.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.10ColumnvirtualDiskWritePolicyread-onlycurrentThe write policy used by the controller for write operations on this virtual disk. Possible values: 1: Write Through. 2: Write Back. 3: Force Write Back.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.11ColumnvirtualDiskReadPolicyread-onlycurrentThe read policy used by the controller for read operations on this virtual disk. Possible values: 1: No Read Ahead. 2: Read Ahead. 3: Adaptive Read Ahead.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13ColumnvirtualDiskLayoutread-onlycurrentThe virtual disk's RAID type. Possible values: 1: Not one of the following 2: RAID-0 3: RAID-1 4: RAID-5 5: RAID-6 6: RAID-10 7: RAID-50 8: RAID-60 9: Concaten…
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.14ColumnvirtualDiskStripeSizeread-onlycurrentThe stripe size of this virtual disk. Possible values: 1: Not one of the following 2: Default. 3: 512 bytes 4: 1 kB, 5: 2 kB, 6: 4 kB, 7: 8 kB, 8: 16 kB, 9: 32…
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20ColumnvirtualDiskComponentStatusread-onlycurrentThe status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other. 2: Unknown. 3: OK. 4: Non-critical …
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23ColumnvirtualDiskBadBlocksDetectedread-onlycurrentIndicates whether the virtual disk has bad blocks.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.24ColumnvirtualDiskSecuredread-onlycurrentIndicates whether the virtual disk is secured or not.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.25ColumnvirtualDiskIsCacheCaderead-onlycurrentIndicates whether the virtual disk is being used as a secondary cache by the controller.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.26ColumnvirtualDiskDiskCachePolicyread-onlycurrentThe cache policy of the physical disks that are part of this virtual disk Possible values: 1: Enabled. 2: Disabled. 3: Default.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30ColumnvirtualDiskOperationalStateread-onlycurrentThe state of the virtual disk when there are progressive operations ongoing. Possible values: 1: There is no active operation running. 2: The virtual disk conf…
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.31ColumnvirtualDiskProgressread-onlycurrentThe progress percentage of the operation that is being performed on the virtual disk. This is applicable only if there is a progressive operations ongoing
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.32ColumnvirtualDiskAvailableProtocolsread-onlycurrentList of protocols support by physical disks part of this virtual disk. For e.g. SAS for Serial Attached SCSI or SATA for Serial Advanced Technology Attachment.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.33ColumnvirtualDiskMediaTyperead-onlycurrentList of media types of the physical disks part of this virtual disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.34ColumnvirtualDiskRemainingRedundancyread-onlycurrentThe number of physical disks which can be lost before the virtual disk loses its redundancy.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.35ColumnvirtualDiskFQDDread-onlycurrentThe virtual disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.36ColumnvirtualDiskDisplayNameread-onlycurrentThe virtual disk's friendly FQDD as represented in Storage Management.
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.37ColumnvirtualDiskT10PIStatusread-onlycurrentIndicates whether the virtual disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible val…
1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.38ColumnvirtualDiskBlockSizeInBytesread-onlycurrentThe block size (in bytes) of the physical disk part of the virtual disk. Possible values: 1: 512. 2: 4096
1.3.6.1.4.1.674.10892.5.6NodeconformanceGroup
1.3.6.1.4.1.674.10892.5.6.1NodeconformanceMIBCompliances
1.3.6.1.4.1.674.10892.5.6.2NodeconformanceMIBGroups
1.3.6.1.4.1.674.10892.5.6.2.1GroupracInfoObjGroupcurrentA collection of objects providing information about the remote access card.
1.3.6.1.4.1.674.10892.5.6.2.2GroupchassisInfoObjGroupcurrentA collection of objects providing information about the Chassis group.
1.3.6.1.4.1.674.10892.5.6.2.3GroupsystemInfoObjGroupcurrentA collection of objects providing information about the System group.
1.3.6.1.4.1.674.10892.5.6.2.4GroupstatusInfoObjGroupcurrentA collection of objects providing information about the status group.
1.3.6.1.4.1.674.10892.5.6.2.5GroupalertInfoObjGroupcurrentA collection of objects providing information about the alert group.
1.3.6.1.4.1.674.10892.5.6.2.6GroupmibVersionInfoObjGroupcurrentA collection of objects providing information about the mib version group.
1.3.6.1.4.1.674.10892.5.6.2.7GroupsystemStateTableInfoObjGroupcurrentA collection of objects providing information about the System State Table group.
1.3.6.1.4.1.674.10892.5.6.2.8GroupchassisInformationObjGroupcurrentA collection of objects providing information about the System chassis information group.
1.3.6.1.4.1.674.10892.5.6.2.9GroupchassisInformationTableObjGroupcurrentA collection of objects providing information about the System chassis information table group.
1.3.6.1.4.1.674.10892.5.6.2.11GroupeventLogTableObjGroupcurrentA collection of objects providing information about the event log table group.
1.3.6.1.4.1.674.10892.5.6.2.12GroupsystemBiosTableObjGroupcurrentA collection of objects providing information about the system Bios table group.
1.3.6.1.4.1.674.10892.5.6.2.13GroupfirmwareTableObjGroupcurrentA collection of objects providing information about the firmware table group.
1.3.6.1.4.1.674.10892.5.6.2.14GroupintrusionTableObjGroupcurrentA collection of objects providing information about the intrusion table group.
1.3.6.1.4.1.674.10892.5.6.2.15GrouplcLogTableObjGroupcurrentA collection of objects providing information about the lc log table group.
1.3.6.1.4.1.674.10892.5.6.2.16GrouppowerUnitTableObjGroupcurrentA collection of objects providing information about the power unit table group.
1.3.6.1.4.1.674.10892.5.6.2.17GrouppowerSupplyTableObjGroupcurrentA collection of objects providing information about the power supply table group.
1.3.6.1.4.1.674.10892.5.6.2.18GroupvoltageProbeTableTableObjGroupcurrentA collection of objects providing information about the Voltage Probe Table group.
1.3.6.1.4.1.674.10892.5.6.2.19GroupamperageProbeTableObjGroupcurrentA collection of objects providing information about the Amperage Probe Table group.
1.3.6.1.4.1.674.10892.5.6.2.20GroupsystemBatteryTableObjGroupcurrentA collection of objects providing information about the System Battery Table group.
1.3.6.1.4.1.674.10892.5.6.2.21GrouppowerUsageTableObjGroupcurrentA collection of objects providing information about the Power Usage Table group.
1.3.6.1.4.1.674.10892.5.6.2.22GroupcoolingUnitTableObjGroupcurrentA collection of objects providing information about the Cooling Unit Table group.
1.3.6.1.4.1.674.10892.5.6.2.23GroupcoolingDeviceTableObjGroupcurrentA collection of objects providing information about the Cooling Device Table group.
1.3.6.1.4.1.674.10892.5.6.2.24GrouptemperatureProbeTableObjGroupcurrentA collection of objects providing information about the Temperature Probe Table group.
1.3.6.1.4.1.674.10892.5.6.2.25GroupprocessorDeviceTableObjGroupcurrentA collection of objects providing information about the Processor Device Table group.
1.3.6.1.4.1.674.10892.5.6.2.26GroupprocessorDeviceStatusTableObjGroupcurrentA collection of objects providing information about the Processor Device Status Table group.
1.3.6.1.4.1.674.10892.5.6.2.27GroupmemoryDeviceTableObjGroupcurrentA collection of objects providing information about the Memory Device Table group.
1.3.6.1.4.1.674.10892.5.6.2.28GrouppCIDeviceTableObjGroupcurrentA collection of objects providing information about the PCI Device Table group.
1.3.6.1.4.1.674.10892.5.6.2.29GroupnetworkDeviceTableObjGroupcurrentA collection of objects providing information about the Network Device Table group.
1.3.6.1.4.1.674.10892.5.6.2.30GroupsystemSlotTableObjGroupcurrentA collection of objects providing information about the System Slot Table group.
1.3.6.1.4.1.674.10892.5.6.2.31GroupfruTableObjGroupcurrentA collection of objects providing information about the Fru Table group.
1.3.6.1.4.1.674.10892.5.6.2.32GroupbatteryTableObjGroupcurrentA collection of objects providing information about the Battery Table group.
1.3.6.1.4.1.674.10892.5.6.2.33GroupcontrollerTableObjGroupcurrentA collection of objects providing information about the Controller Table group.
1.3.6.1.4.1.674.10892.5.6.2.34GroupphysicalDiskTableObjGroupcurrentA collection of objects providing information about the Physical Disk Table group.
1.3.6.1.4.1.674.10892.5.6.2.35GroupvirtualDiskTableObjGroupcurrentA collection of objects providing information about the Virtual Disk Table group.
1.3.6.1.4.1.674.10892.5.6.2.36GroupenclosureTableObjGroupcurrentA collection of objects providing information about the Enclosure Table group.
1.3.6.1.4.1.674.10892.5.6.2.37GroupenclosureManagementModuleTableObjGroupcurrentA collection of objects providing information about the Enclosure Management Module Table group.
1.3.6.1.4.1.674.10892.5.6.2.38GroupenclosureFanTableObjGroupcurrentA collection of objects providing information about the Enclosure Fan Table group.
1.3.6.1.4.1.674.10892.5.6.2.39GroupenclosurePowerSupplyTableObjGroupcurrentA collection of objects providing information about the Enclosure Power Supply Table group.
1.3.6.1.4.1.674.10892.5.6.2.40GroupenclosureTemperatureProbeTableObjGroupcurrentA collection of objects providing information about the Enclosure Temperature Probe Table group.
1.3.6.1.4.1.674.10892.5.6.4NodeconformanceMIBnotificationGroup
1.3.6.1.4.1.674.10892.5.6.4.1GroupalertnotificationcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.2GroupalertAutomaticSystemRecoveryTrapNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.3GroupalertBatteryTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.4GroupcableTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.5GroupcmcTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.6GroupprocessorDeviceStatusTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.7GroupprocessorDeviceAbsentTrapNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.8GroupfanTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.9GroupfiberChannelTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.10GrouphardwareConfigurationTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.11GroupioVirtualizationTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.12GrouplinkStatusTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.13GroupmemoryDeviceTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.14GroupnicTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.15GrouposTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.16GrouppciDeviceTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.17GroupphysicaldiskTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.18GroupbiosPOSTTrapNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.19GrouppowerSupplyTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.20GrouppowerSupplyAbsentTrapNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.21GrouppowerUsageTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.22GroupredundancyTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.23GroupintegratedDualSDModuleTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.24GroupintegratedDualSDModuleAbsentTrapNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.25GroupintegratedDualSDModuleRedundancyTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.26GroupsecurityEventTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.27GroupsystemEventLogTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.28GroupsoftwareConfigurationTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.29GrouptemperatureProbeTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.30GrouptemperatureStatisticsTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.31GroupvFlashMediaDeviceTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.32GroupvFlashMediaDeviceAbsentTrapNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.33GroupvoltageProbeTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.34GroupracTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.35GroupsystemPerformanceTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.36GroupbatteryTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.37GroupstorageControllerTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.38GroupenclosureTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.39GroupfanStorageTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.40GroupphysicalDiskTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.41GroupstoragePowerSupplyTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.42GroupalertStorageSecurityTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.43GroupalertStorageManagementTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.44GroupalertStorageTemperatureProbeTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.45GroupalertStorageVirtualDiskTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.46GroupalertUpdateJobTrapNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.47GroupalertSoftwareChangeUpdateNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.48GroupalertCMCAuditNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.49GroupalertDebugNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.50GroupalertiDRACIPAddressChangeNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.51GroupalertLicenseNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.52GroupalertPCIDeviceAuditNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.53GroupalertPowerSupplyAuditNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.54GroupalertPowerUsageAuditNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.55GroupalertSystemPowerStateChangeNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.56GroupalertUserTrackingNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.57GroupalertAutoDiscoveryNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.58GroupalertNetworkConfigurationNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.59GroupalertIPAddressConfigurationNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.60GroupalertJobControlConfigurationNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.61GroupalertPCIDeviceConfigurationNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.62GroupalertSecurityConfigurationNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.63GroupalertSWCConfigurationNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.64GroupalertTestTrapNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.65GroupalertInternaliDRACMemoryUnresponsiveTrapNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.66GroupstorageSolidstateDriveTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.67GroupalertConfigurationChangeAuditNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.68GroupalertServerIdleTimeNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.69GroupalertHWCAuditNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.70GroupliquidCoolingTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.71GroupalertStorageSoftwareDefinedSubSystemTrapsNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.72GroupalertTemparatureProbeAuditNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.74GroupalertPRDeviceDetectionNotificationGroupcurrentThe one notification which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.75GroupalertSystemConfigurationNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.76GroupalertSDKConfigurationNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.77GroupalertSDKSystemNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.78GroupalertCertificateValidityNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
1.3.6.1.4.1.674.10892.5.6.4.79GroupalertSDPMSystemNotificationGroupcurrentThe two notifications which an SNMPv2 entity is required to implement.
Type Definitions
NameSyntaxStatusDescription
AmperageDiscreteReadingEnumINTEGER { amperageIsGood(1), amperageIsBad(2) }currentAmperage Discrete Reading Enum.
AmperageProbeTypeEnumINTEGER { amperageProbeTypeIsOther(1), amperageProbeTypeIsUnknown(2), amperageProbeTypeIs1Point5Volt(3), amperageProbeTypeIs3Point3volt(4), amperageProbeTypeIs5Volt(5), amperageProbeTypeIsMinus5Volt(6), amperageProbeTypeIs12Volt(7), amperageProbeTypeIsMinus12Volt(8), amperageProbeTypeIsIO(9), amperageProbeTypeIsCore(10), amperageProbeTypeIsFLEA(11), amperageProbeTypeIsBattery(12), amperageProbeTypeIsTerminator(13), amperageProbeTypeIs2Point5Volt(14), amperageProbeTypeIsGTL(15), amperageProbeTypeIsDiscrete(16), amperageProbeTypeIsPowerSupplyAmps(23), amperageProbeTypeIsPowerSupplyWatts(24), amperageProbeTypeIsSystemAmps(25), amperageProbeTypeIsSystemWatts(26) }currentAmperage Probe Type Enum.
BladeGeometryEnumINTEGER { other(1), unknown(2), singleWidthHalfHeight(3), dualWidthHalfHeight(4), singleWidthFullHeight(5), dualWidthFullHeight(6), singleWidthQuarterHeight(7), u1HalfWidth(8), u1QuarterWidth(9), u1FullWidth(10) }currentBlade Geometry enum.
BooleanTypeINTEGER (0..1)currentInteger with a range of (0..1). Where 0 = FALSE, 1 = TRUE
ChassisIdentifyControlCapabilitiesFlagsINTEGER { unknownCapabilities(1), enableCapable(2), notReadyCapable(4), identifyCapable(8) }currentChassis Identify Control Capabilities Flags.
ChassisIdentifyControlSettingsFlagsINTEGER { unknown(1), enabled(2), notReady(4), identifyChassis(8), identifyChassisAndEnable(10) }currentChassis Identify Control Settings Flags.
ChassisSystemClassEnumINTEGER { other(1), unknown(2), workstationClass(3), serverClass(4), desktopClass(5), portableClass(6), netPCClass(7), storageClass(8) }currentChassis System Class Enum.
ChassisTypeEnumINTEGER { other(1), unknown(2), desktop(3), lowProfileDesktop(4), pizzaBox(5), miniTower(6), tower(7), portable(8), lapTop(9), noteBook(10), handHeld(11), dockingStation(12), allInOne(13), subNoteBook(14), spaceSaving(15), lunchBox(16), mainSystemChassis(17), expansionChassis(18), subChassis(19), busExpansionChassis(20), peripheralChassis(21), raidChassis(22), rackMountChassis(23), sealedCasePC(24), multiSystemChassis(25) }currentChassis Type Enum.
CoolingDeviceDiscreteReadingEnumINTEGER { coolingDeviceIsGood(1), coolingDeviceIsBad(2) }currentCooling Device Discrete Reading Enum.
CoolingDeviceSubTypeEnumINTEGER { coolingDeviceSubTypeIsOther(1), coolingDeviceSubTypeIsUnknown(2), coolingDeviceSubTypeIsAFanThatReadsInRPM(3), coolingDeviceSubTypeIsAFanReadsONorOFF(4), coolingDeviceSubTypeIsAPowerSupplyFanThatReadsinRPM(5), coolingDeviceSubTypeIsAPowerSupplyFanThatReadsONorOFF(6), coolingDeviceSubTypeIsDiscrete(16) }currentCooling Device Sub Type Enum.
CoolingDeviceTypeEnumINTEGER { coolingDeviceTypeIsOther(1), coolingDeviceTypeIsUnknown(2), coolingDeviceTypeIsAFan(3), coolingDeviceTypeIsABlower(4), coolingDeviceTypeIsAChipFan(5), coolingDeviceTypeIsACabinetFan(6), coolingDeviceTypeIsAPowerSupplyFan(7), coolingDeviceTypeIsAHeatPipe(8), coolingDeviceTypeIsRefrigeration(9), coolingDeviceTypeIsActiveCooling(10), coolingDeviceTypeIsPassiveCooling(11) }currentCooling Device Type Enum.
DateNameOCTET STRING (SIZE (25))currentString type for date strings of a given DateName format.
FirmwareTypeINTEGER { other(1), unknown(2), lifecycleController(20), iDRAC7(21), iDRAC8(22), iDRAC9(23) }currentFirmware Type.
FQDDStringOCTET STRING (SIZE (0..512))currentString type for FQDD strings.
HostControlCapabilitiesFlagsINTEGER { manualRebootCapable(1), manualPowerOFFCapable(2), manualPowerCycleCapable(4), manualAllExceptOperatingSystemShutdownCapable(7), manualOperatingSystemShutdownCapable(8), manualFullyCapable(15), manualRebootWithOSShutdownCapable(16), manualRebootWithoutOSShutdownCapable(32), manualPowerOffWithOSShutdownCapable(64), manualPowerOffWithoutOSShutdownCapable(128), manualPowerCycleWithOSShutdownCapable(256), manualPowerCycleWithoutOSShutdownCapable(512) }currentHost Control Capabilities Flags.
HostControlSettingsFlagsINTEGER { manualReboot(1), manualPowerOFF(2), manualPowerCycle(4), manualOperatingSystemShutdown(8), manualOperatingSystemShutdownThenReboot(9), manualOperatingSystemShutdownThenPowerOFF(10), manualOperatingSystemShutdownThenPowerCycle(12) }currentHost Control Settings Flags.
IntrusionReadingEnumINTEGER { chassisNotBreached(1), chassisBreached(2), chassisBreachedPrior(3), chassisBreachSensorFailure(4) }currentIntrusion Reading Enum.
IntrusionTypeEnumINTEGER { chassisBreachDetectionWhenPowerON(1), chassisBreachDetectionWhenPowerOFF(2) }currentIntrusion Type Enum.
LcLogCategoryEnumINTEGER { system(1), storage(2), updates(3), audit(4), configuration(5), workNotes(6) }currentLC Log Category Enum.
LEDControlCapabilitiesFlagsINTEGER { unknown(1), alertOnErrorCapable(2), alertOnWarningAndErrorCapable(4), alertOnWarningOrErrorCapable(6) }currentLED Control Capabilities Flags.
LEDControlSettingsFlagsINTEGER { unknown(1), alertOnError(2), alertOnWarningAndError(4) }currentLED Control Settings Flags.
LogFormatTypeINTEGER { raw(1), ascii(2), uniCode(3) }currentLog Format Type.
MACAddressOCTET STRING (SIZE (6))currentString type for MAC Address strings.
MemoryDeviceTypeEnumINTEGER { deviceTypeIsOther(1), deviceTypeIsUnknown(2), deviceTypeIsDRAM(3), deviceTypeIsEDRAM(4), deviceTypeIsVRAM(5), deviceTypeIsSRAM(6), deviceTypeIsRAM(7), deviceTypeIsROM(8), deviceTypeIsFLASH(9), deviceTypeIsEEPROM(10), deviceTypeIsFEPROM(11), deviceTypeIsEPROM(12), deviceTypeIsCDRAM(13), deviceTypeIs3DRAM(14), deviceTypeIsSDRAM(15), deviceTypeIsSGRAM(16), deviceTypeIsRDRAM(17), deviceTypeIsDDR(18), deviceTypeIsDDR2(19), deviceTypeIsDDR2FBDIMM(20), deviceTypeIsDDR3(24), deviceTypeIsFBD2(25), deviceTypeIsDDR4(26) }currentMemory Device Type Enum.
MemoryPropertyEnumINTEGER { notApplicable(255) }currentMemory Property Enum.
MemoryTechnologyEnumINTEGER { other(1), unknown(2), dram(3), nvdimmn(4), nvdimmf(5), nvdimmp(6), intelpersistentmemory(7) }currentMemory Technology Enum.
NetworkDeviceCapabilitiesFlagsINTEGER { supported(1), toe(2), iscsiOffload(4), fcoeOffload(8) }currentNetwork Device Capabilities Flags.
NetworkDeviceConnectionStatusEnumINTEGER { connected(1), disconnected(2), driverBad(3), driverDisabled(4), hardwareInitalizing(10), hardwareResetting(11), hardwareClosing(12), hardwareNotReady(13) }currentNetwork Device Connection Status Enum.
NetworkDeviceiSCSICapabilityFlagsINTEGER { unknown(1), available(2), notAvailable(4), cannotBeDetermined(8), driverNotResponding(16) }currentNetwork Device iSCSI Capability Flags.
NetworkDeviceTOECapabilityFlagsINTEGER { unknown(1), available(2), notAvailable(4), cannotBeDetermined(8), driverNotResponding(16) }currentNetwork Device TOE Capability Flags.
NMIButtonControlCapabilitiesFlagsINTEGER { unknownCapabilities(1), enableCapable(2) }currentNMI Button Control Capabilities Flags.
NMIButtonControlSettingsFlagsINTEGER { unknown(1), enabled(2), disabled(4) }currentNMI Button Control Settings Flags.
ObjectRangeINTEGER (1..128)currentInteger with a range of (1..128).
ObjectStatusEnumINTEGER { other(1), unknown(2), ok(3), nonCritical(4), critical(5), nonRecoverable(6) }currentStatus of an object.
PowerButtonControlCapabilitiesFlagsINTEGER { unknownCapabilities(1), enableCapable(2) }currentPower Button Control Capabilities Flags.
PowerButtonControlSettingsFlagsINTEGER { unknown(1), enabled(2), disabled(4) }currentPower Button Control Settings Flags.
PowerCapCapabilitiesFlagsINTEGER { enable(1), disable(2) }currentPower Cap Capabilities Flags.
PowerCapSettingEnumINTEGER { enabled(1) }currentPower Cap Setting Enum.
PowerStateStatusEnumINTEGER { other(1), unknown(2), off(3), on(4) }currentPower State Status enum.
PowerSupplyConfigurationErrorTypeEnumINTEGER { vendorMismatch(1), revisionMismatch(2), processorMissing(3) }currentPower Supply Configuration Error Type Enum.
PowerSupplySensorStateFlagsINTEGER { presenceDetected(1), psFailureDetected(2), predictiveFailure(4), psACLost(8), acLostOrOutOfRange(16), acOutOfRangeButPresent(32), configurationError(64) }currentPower Supply Sensor State Flags.
PowerSupplyStateCapabilitiesUniqueFlagsINTEGER { unknown(1), onlineCapable(2), notReadyCapable(4) }currentPower Supply State Capabilities Unique Flags.
PowerSupplyStateSettingsUniqueFlagsINTEGER { unknown(1), onLine(2), notReady(4), fanFailure(8), onlineAndFanFailure(10), powerSupplyIsON(16), powerSupplyIsOK(32), acSwitchIsON(64), onlineandAcSwitchIsON(66), acPowerIsON(128), onlineAndAcPowerIsON(130), onlineAndPredictiveFailure(210), acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline(242) }currentPower Supply State Settings Unique Flags.
PowerSupplyTypeEnumINTEGER { powerSupplyTypeIsOther(1), powerSupplyTypeIsUnknown(2), powerSupplyTypeIsLinear(3), powerSupplyTypeIsSwitching(4), powerSupplyTypeIsBattery(5), powerSupplyTypeIsUPS(6), powerSupplyTypeIsConverter(7), powerSupplyTypeIsRegulator(8), powerSupplyTypeIsAC(9), powerSupplyTypeIsDC(10), powerSupplyTypeIsVRM(11) }currentPower Supply Type Enum.
ProbeCapabilitiesFlagsINTEGER { upperNonCriticalThresholdSetCapable(1), lowerNonCriticalThresholdSetCapable(2), upperNonCriticalThresholdDefaultCapable(4), lowerNonCriticalThresholdDefaultCapable(8) }currentProbe Capabilities flags.
ProcessorDeviceFamilyINTEGER { deviceFamilyIsOther(1), deviceFamilyIsUnknown(2), deviceFamilyIs8086(3), deviceFamilyIs80286(4), deviceFamilyIsIntel386(5), deviceFamilyIsIntel486(6), deviceFamilyIs8087(7), deviceFamilyIs80287(8), deviceFamilyIs80387(9), deviceFamilyIs80487(10), deviceFamilyIsPentium(11), deviceFamilyIsPentiumPro(12), deviceFamilyIsPentiumII(13), deviceFamilyIsPentiumMMX(14), deviceFamilyIsCeleron(15), deviceFamilyIsPentiumIIXeon(16), deviceFamilyIsPentiumIII(17), deviceFamilyIsPentiumIIIXeon(18), deviceFamilyIsPentiumIIISpeedStep(19), deviceFamilyIsItanium(20), deviceFamilyIsIntelXeon(21), deviceFamilyIsPentium4(22), deviceFamilyIsIntelXeonMP(23), deviceFamilyIsIntelItanium2(24), deviceFamilyIsK5(25), deviceFamilyIsK6(26), deviceFamilyIsK6Dash2(27), deviceFamilyIsK6Dash3(28), deviceFamilyIsAMDAthlon(29), deviceFamilyIsAMD2900(30), deviceFamilyIsK6Dash2Plus(31), deviceFamilyIsPowerPC(32), deviceFamilyIsPowerPC601(33), deviceFamilyIsPowerPC603(34), deviceFamilyIsPowerPC603Plus(35), deviceFamilyIsPowerPC604(36), deviceFamilyIsPowerPC620(37), deviceFamilyIsPowerPCx704(38), deviceFamilyIsPowerPC750(39), deviceFamilyIsIntelCoreDuo(40), deviceFamilyIsIntelCoreDuoMobile(41), deviceFamilyIsIntelCoreSoloMobile(42), deviceFamilyIsIntelAtom(43), deviceFamilyIsAlpha(48), deviceFamilyIsAlpha21064(49), deviceFamilyIsAlpha21066(50), deviceFamilyIsAlpha21164(51), deviceFamilyIsAlpha21164PC(52), deviceFamilyIsAlpha21164a(53), deviceFamilyIsAlpha21264(54), deviceFamilyIsAlpha21364(55), deviceFamilyIsAMDTurionIIUltraDualMobileM(56), deviceFamilyIsAMDTurionIIDualMobileM(57), deviceFamilyIsAMDAthlonIIDualMobileM(58), deviceFamilyIsAMDOpteron6100(59), deviceFamilyIsAMDOpteron4100(60), deviceFamilyIsAMDOpteron6200(61), deviceFamilyIsAMDOpteron4200(62), deviceFamilyIsMIPS(64), deviceFamilyIsMIPSR4000(65), deviceFamilyIsMIPSR4200(66), deviceFamilyIsMIPSR4400(67), deviceFamilyIsMIPSR4600(68), deviceFamilyIsMIPSR10000(69), deviceFamilyIsSPARC(80), deviceFamilyIsSuperSPARC(81), deviceFamilyIsmicroSPARCII(82), deviceFamilyIsmicroSPARCIIep(83), deviceFamilyIsUltraSPARC(84), deviceFamilyIsUltraSPARCII(85), deviceFamilyIsUltraSPARCIIi(86), deviceFamilyIsUltraSPARCIII(87), deviceFamilyIsUltraSPARCIIIi(88), deviceFamilyIs68040(96), deviceFamilyIs68xxx(97), deviceFamilyIs68000(98), deviceFamilyIs68010(99), deviceFamilyIs68020(100), deviceFamilyIs68030(101), deviceFamilyIsAMDZen(107), deviceFamilyIsHobbit(112), deviceFamilyIsCrusoeTM5000(120), deviceFamilyIsCrusoeTM3000(121), deviceFamilyIsEfficeonTM8000(122), deviceFamilyIsWeitek(128), deviceFamilyIsIntelCeleronM(130), deviceFamilyIsAMDAthlon64(131), deviceFamilyIsAMDOpteron(132), deviceFamilyIsAMDSempron(133), deviceFamilyIsAMDTurion64Mobile(134), deviceFamilyIsDualCoreAMDOpteron(135), deviceFamilyIsAMDAthlon64X2DualCore(136), deviceFamilyIsAMDTurion64X2Mobile(137), deviceFamilyIsQuadCoreAMDOpteron(138), deviceFamilyIsThirdGenerationAMDOpteron(139), deviceFamilyIsAMDPhenomFXQuadCore(140), deviceFamilyIsAMDPhenomX4QuadCore(141), deviceFamilyIsAMDPhenomX2DualCore(142), deviceFamilyIsAMDAthlonX2DualCore(143), deviceFamilyIsPARISC(144), deviceFamilyIsPARISC8500(145), deviceFamilyIsPARISC8000(146), deviceFamilyIsPARISC7300LC(147), deviceFamilyIsPARISC7200(148), deviceFamilyIsPARISC7100LC(149), deviceFamilyIsPARISC7100(150), deviceFamilyIsV30(160), deviceFamilyIsQuadCoreIntelXeon3200(161), deviceFamilyIsDualCoreIntelXeon3000(162), deviceFamilyIsQuadCoreIntelXeon5300(163), deviceFamilyIsDualCoreIntelXeon5100(164), deviceFamilyIsDualCoreIntelXeon5000(165), deviceFamilyIsDualCoreIntelXeonLV(166), deviceFamilyIsDualCoreIntelXeonULV(167), deviceFamilyIsDualCoreIntelXeon7100(168), deviceFamilyIsQuadCoreIntelXeon5400(169), deviceFamilyIsQuadCoreIntelXeon(170), deviceFamilyIsDualCoreIntelXeon5200(171), deviceFamilyIsDualCoreIntelXeon7200(172), deviceFamilyIsQuadCoreIntelXeon7300(173), deviceFamilyIsQuadCoreIntelXeon7400(174), deviceFamilyIsMultiCoreIntelXeon7400(175), deviceFamilyIsM1(176), deviceFamilyIsM2(177), deviceFamilyIsIntelPentium4HT(179), deviceFamilyIsAS400(180), deviceFamilyIsAMDAthlonXP(182), deviceFamilyIsAMDAthlonMP(183), deviceFamilyIsAMDDuron(184), deviceFamilyIsIntelPentiumM(185), deviceFamilyIsIntelCeleronD(186), deviceFamilyIsIntelPentiumD(187), deviceFamilyIsIntelPentiumExtreme(188), deviceFamilyIsIntelCoreSolo(189), deviceFamilyIsIntelCore2(190), deviceFamilyIsIntelCore2Duo(191), deviceFamilyIsIntelCore2Solo(192), deviceFamilyIsIntelCore2Extreme(193), deviceFamilyIsIntelCore2Quad(194), deviceFamilyIsIntelCore2ExtremeMobile(195), deviceFamilyIsIntelCore2DuoMobile(196), deviceFamilyIsIntelCore2SoloMobile(197), deviceFamilyIsIntelCorei7(198), deviceFamilyIsDualCoreIntelCeleron(199), deviceFamilyIsIBM390(200), deviceFamilyIsG4(201), deviceFamilyIsG5(202), deviceFamilyIsESA390G6(203), deviceFamilyIszArchitectur(204), deviceFamilyIsIntelCorei5(205), deviceFamilyIsIntelCorei3(206), deviceFamilyIsVIAC7M(210), deviceFamilyIsVIAC7D(211), deviceFamilyIsVIAC7(212), deviceFamilyIsVIAEden(213), deviceFamilyIsMultiCoreIntelXeon(214), deviceFamilyIsDualCoreIntelXeon3xxx(215), deviceFamilyIsQuadCoreIntelXeon3xxx(216), deviceFamilyIsVIANano(217), deviceFamilyIsDualCoreIntelXeon5xxx(218), deviceFamilyIsQuadCoreIntelXeon5xxx(219), deviceFamilyIsDualCoreIntelXeon7xxx(221), deviceFamilyIsQuadCoreIntelXeon7xxx(222), deviceFamilyIsMultiCoreIntelXeon7xxx(223), deviceFamilyIsMultiCoreIntelXeon3400(224), deviceFamilyIsEmbeddedAMDOpertonQuadCore(230), deviceFamilyIsAMDPhenomTripleCore(231), deviceFamilyIsAMDTurionUltraDualCoreMobile(232), deviceFamilyIsAMDTurionDualCoreMobile(233), deviceFamilyIsAMDAthlonDualCore(234), deviceFamilyIsAMDSempronSI(235), deviceFamilyIsAMDPhenomII(236), deviceFamilyIsAMDAthlonII(237), deviceFamilyIsSixCoreAMDOpteron(238), deviceFamilyIsAMDSempronM(239), deviceFamilyIsi860(250), deviceFamilyIsi960(251) }currentProcessor Device Family.
ProcessorDeviceStatusReadingFlagsINTEGER { internalError(1), thermalTrip(2), configurationError(32), processorPresent(128), processorDisabled(256), terminatorPresent(512), processorThrottled(1024) }currentProcessor Device Status Reading Flags.
ProcessorDeviceStatusStateINTEGER { other(1), unknown(2), enabled(3), userDisabled(4), biosDisabled(5), idle(6) }currentProcessor Device Status State.
ProcessorDeviceTypeINTEGER { deviceTypeIsOther(1), deviceTypeIsUnknown(2), deviceTypeIsCPU(3), deviceTypeIsMathProcessor(4), deviceTypeIsDSP(5), deviceTypeIsAVideoProcessor(6) }currentProcessor Device Type.
RacTypeEnumINTEGER { other(1), unknown(2), idrac7monolithic(16), idrac7modular(17), idrac7DCS(21), idrac8monolithic(32), idrac8modular(33), idrac8DCS(34), idrac9Monolithic(48), idrac9Modular(49), idrac9DCS(50), idrac915GMonolithic(64), idrac915GModular(65), idrac915GDCS(66) }currentRAC Type enum.
Signed32BitRangeINTEGER (-2147483647..2147483647)currentInteger with a range of (-2147483647..2147483647).
StateCapabilitiesFlagsINTEGER { unknownCapabilities(1), enableCapable(2), notReadyCapable(4), enableAndNotReadyCapable(6) }currentState Capabilities flags.
StateCapabilitiesLogUniqueFlagsINTEGER { unknown(1), onlineCapable(2), notReadyCapable(4), resetCapable(8) }currentState Capabilities Log Unique Flags.
StateSettingsFlagsINTEGER { unknown(1), enabled(2), notReady(4), enabledAndNotReady(6) }currentState Settings flags.
StateSettingsLogUniqueFlagsINTEGER { unknown(1), online(2), notReady(4), reset(8) }currentState Settings Log Unique Flags.
StatusProbeEnumINTEGER { other(1), unknown(2), ok(3), nonCriticalUpper(4), criticalUpper(5), nonRecoverableUpper(6), nonCriticalLower(7), criticalLower(8), nonRecoverableLower(9), failed(10) }currentProbe Status enum.
StatusRedundancyEnumINTEGER { other(1), unknown(2), full(3), degraded(4), lost(5), notRedundant(6), redundancyOffline(7) }currentRedundancy Status enum.
String64OCTET STRING (SIZE (0..64))currentGeneral string type for 64 byte strings.
StringTypeOCTET STRING (SIZE (0..1023))currentGeneral string type.
SystemBatteryReadingFlagsINTEGER { predictiveFailure(1), failed(2), presenceDetected(4) }currentSystem Battery Reading Flags.
SystemFormFactorEnumINTEGER { other(1), unknown(2), u1(3), u2(4), u4(5), u7(6), singleWidthHalfHeight(7), dualWidthHalfHeight(8), singleWidthFullHeight(9), dualWidthFullHeight(10), singleWidthQuarterHeight(11), u5(12), u1HalfWidth(13), u1QuarterWidth(14), u1FullWidth(15) }currentSystem Form Factor enum.
SystemLockdownModeEnumINTEGER { enabled(1), unknown(2) }currentState Capabilities flags.
SystemPropertiesFlagsINTEGER { energySmart(1) }currentSystem Properties Flags.
SystemSlotCategoryEnumINTEGER { systemSlotCategoryIsOther(1), systemSlotCategoryIsUnknown(2), systemSlotCategoryIsBusConnector(3), systemSlotCategoryIsPCMCIA(4), systemSlotCategoryIsMotherboard(5) }currentSystem Slot Category Enum.
SystemSlotStateCapabilitiesFlagsINTEGER { systemSlotHotPlugIsUnknown(1), systemSlotHotPlugIsHotPluggableCapable(2), systemSlotHotPlugCanBePoweredOn(4), systemSlotHotPlugCanSignalAttention(8), systemSlotHotPlugCanSignalPowerFault(16), systemSlotHotPlugCanSignalAdapterPresent(32), systemSlotHotPlugCanSignalPowerButtonPressed(64), canSupportAllHotPlugCapabilities(126), systemSlotCanProvide5Volts(128), systemSlotCanProvide3Point3Volts(256), systemSlotCanSignalIfShared(512), systemSlotCanSupportCard16(1024), systemSlotCanSupportCardBus(2048), systemSlotCanSupportZoomVideo(4096), systemSlotCanSupportModemRingResume(8192), systemSlotCanSupportPMESignal(16384), canSupportAllSlotCapabilities(32640), canSupportAllSlotAndAllHotPlugCapabilities(32766) }currentSystem Slot State Capabilities Flags.
SystemSlotStateSettingsFlagsINTEGER { systemSlotHotPlugIsUnknown(1), systemSlotHotPlugIsHotPluggable(2), systemSlotHotPlugIsPoweredOn(4), systemSlotHotPlugIsAtAttention(8), systemSlotHotPlugHasPowerFaulted(16), systemSlotHotPlugAdapterIsPresent(32), systemSlotHotPlugAdapterPresentAndPoweredOn(36), systemSlotHotPlugPowerButtonPressed(64), systemSlotProvides5Volts(128), systemSlotProvides3Point3Volts(256), systemSlotIsShared(512), systemSlotSupportsCard16(1024), systemSlotSupportsCardBus(2048), systemSlotSupportsZoomVideo(4096), systemSlotSupportsModemRingResume(8192), systemSlotSupportsPMESignal(16384), supportsPMEand3P3Vand5VandHotPluggable(16770), supportsPMEand3P3Vand5VhasAdapterOn(16804), supportsPMEand3P3Vand5VhasAdapterOnandisHotPluggable(16806), supportsPMEand3P3VIsSharedand5VhasAdapterOnandHotPlugable(17316) }currentSystem Slot State Settings Flags.
SystemSlotTypeEnumINTEGER { systemSlotIsOther(1), systemSlotIsUnknown(2), systemSlotIsISA(3), systemSlotIsMCA(4), systemSlotIsEISA(5), systemSlotIsPCI(6), systemSlotIsPCMCIA(7), systemSlotIsVLVESA(8), systemSlotIsProprietary(9), systemSlotIsProcessorCard(10), systemSlotIsProprietaryMemory(11), systemSlotIsIORiserCard(12), systemSlotIsNuBUS(13), systemSlotIsPCI66MHz(14), systemSlotIsAGP(15), systemSlotIsAGP2X(16), systemSlotIsAGP4X(17), systemSlotIsPC98C20(18), systemSlotIsPC98C24(19), systemSlotIsPC98E(20), systemSlotIsPC98LocalBus(21), systemSlotIsPC98Card(22), systemSlotIsPCIX(23), systemSlotIsPCIExpress(24), systemSlotIsAGP8X(25), systemSlotIsPCIExpressX1(166), systemSlotIsPCIExpressX2(167), systemSlotIsPCIExpressX4(168), systemSlotIsPCIExpressX8(169), systemSlotIsPCIExpressX16(170), systemSlotIsPCIExpressGen2(171), systemSlotIsPCIExpressGen2X1(172), systemSlotIsPCIExpressGen2X2(173), systemSlotIsPCIExpressGen2X4(174), systemSlotIsPCIExpressGen2X8(175), systemSlotIsPCIExpressGen2X16(176) }currentSystem Slot Type Enum.
SystemSlotUsageEnumINTEGER { systemSlotUsageIsOther(1), systemSlotUsageIsUnknown(2), systemSlotUsageIsAvailable(3), systemSlotUsageIsInUse(4) }currentSystem Slot Usage Enum.
TemperatureDiscreteReadingEnumINTEGER { temperatureIsGood(1), temperatureIsBad(2) }currentTemperature Discrete Reading Enum.
TemperatureProbeTypeEnumINTEGER { temperatureProbeTypeIsOther(1), temperatureProbeTypeIsUnknown(2), temperatureProbeTypeIsAmbientESM(3), temperatureProbeTypeIsDiscrete(16) }currentTemperature Probe Type Enum.
Unsigned16BitRangeINTEGER (0..65535)currentInteger with a range of (0..65535).
Unsigned32BitRangeINTEGER (0..2147483647)currentInteger with a range of (0..2147483647).
Unsigned8BitRangeINTEGER (0..255)currentInteger with a range of (0..255).
VoltageDiscreteReadingEnumINTEGER { voltageIsGood(1), voltageIsBad(2) }currentVoltage Discrete Reading Enum.
VoltageTypeEnumINTEGER { voltageProbeTypeIsOther(1), voltageProbeTypeIsUnknown(2), voltageProbeTypeIs1Point5Volt(3), voltageProbeTypeIs3Point3Volt(4), voltageProbeTypeIs5Volt(5), voltageProbeTypeIsMinus5Volt(6), voltageProbeTypeIs12Volt(7), voltageProbeTypeIsMinus12Volt(8), voltageProbeTypeIsIO(9), voltageProbeTypeIsCore(10), voltageProbeTypeIsFLEA(11), voltageProbeTypeIsBattery(12), voltageProbeTypeIsTerminator(13), voltageProbeTypeIs2Point5Volt(14), voltageProbeTypeIsGTL(15), voltageProbeTypeIsDiscrete(16), voltageProbeTypeIsGenericDiscrete(17), voltageProbeTypeIsPSVoltage(18), voltageProbeTypeIsMemoryStatus(19) }currentVoltage Type Enum.
WatchControlSettingsFlagsINTEGER { automaticRebootEnabled(1), automaticPowerCycleEnabled(2), automaticNotificationEnabled(4), automaticPowerOffEnabled(8) }currentWatchDog Control Settings Flags.
WatchDogControlCapabilitiesFlagsINTEGER { automaticRebootCapable(1), automaticPowerCycleCapable(2), automaticNotificationCapable(4), automaticWatchDogTimerCapable(8), automaticPowerOffCapable(16), automaticAllExceptNotificationCapable(27), automaticFullyCapable(31) }currentWatchDog Control Capabilities Flags.
WatchDogTimerCapabilitiesFlagsINTEGER { type1Capable(1), type2Capable(2), type3Capable(4) }currentWatchDog Timer Capabilities Flags.