MIB Viewer

IMM-MIB

1085 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC-1215TRAP-TYPE
RFC1155-SMI2011 Gauge enterprises IpAddress
RFC1213-MIBDisplayString
SNMPv2-TC-- TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.4.1.2Nodeibm
1.3.6.1.4.1.2.3NodeibmAgents
1.3.6.1.4.1.2.3.51NodenetfinitySupportProcessorAgent
1.3.6.1.4.1.2.3.51.3NodeibmIntegratedManagementModuleMIB
1.3.6.1.4.1.2.3.51.3.1Nodemonitors
1.3.6.1.4.1.2.3.51.3.1.1Nodetemperature
1.3.6.1.4.1.2.3.51.3.1.1.1ScalartempNumberread-onlymandatoryThe present number of rows in the temperature table.
1.3.6.1.4.1.2.3.51.3.1.1.2TabletempTablenot-accessiblemandatoryThis table contains temperature measurement information.
1.3.6.1.4.1.2.3.51.3.1.1.2.1RowtempEntrynot-accessiblemandatoryEach row contains parameters related to a temperature measurement channel.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.1ColumntempIndexread-onlymandatoryThis column is used to identify a particular temperature measurement channel.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.2ColumntempDescrread-onlymandatoryA description of the temperature measurement channel.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.3ColumntempReadingread-onlymandatoryThe measured temperature.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.4ColumntempNominalReadingread-onlymandatoryThe nominal temperature, if available.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.5ColumntempNonRecovLimitHighread-onlymandatoryThe non-recoverable limit for the measured temperature. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.6ColumntempCritLimitHighread-onlymandatoryThe critical limit for the measured temperature. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.7ColumntempNonCritLimitHighread-onlymandatoryThe non-critical limit for the measured temperature. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.8ColumntempNonRecovLimitLowread-onlymandatoryThe non-recoverable limit for the measured temperature. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.9ColumntempCritLimitLowread-onlymandatoryThe critical limit for the measured temperature. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.10ColumntempNonCritLimitLowread-onlymandatoryThe non-critical limit for the measured temperature. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.1.2.1.11ColumntempHealthStatusread-onlymandatoryA description of the temperature component status.
1.3.6.1.4.1.2.3.51.3.1.2Nodevoltage
1.3.6.1.4.1.2.3.51.3.1.2.1ScalarvoltNumberread-onlymandatoryThe present number of rows in the voltage table.
1.3.6.1.4.1.2.3.51.3.1.2.2TablevoltTablenot-accessiblemandatoryThis table contains voltage measurement information.
1.3.6.1.4.1.2.3.51.3.1.2.2.1RowvoltEntrynot-accessiblemandatoryEach row contains parameters related to a voltage measurement channel.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.1ColumnvoltIndexread-onlymandatoryThis column is used to identify a particular voltage measurement channel.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.2ColumnvoltDescrread-onlymandatoryA description of the voltage measurement channel.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.3ColumnvoltReadingread-onlymandatoryThe measured voltage.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.4ColumnvoltNominalReadingread-onlymandatoryThe nominal voltage, if available.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.5ColumnvoltNonRecovLimitHighread-onlymandatoryThe high non-recoverable limit for the measured voltage. If the measured value falls above this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.6ColumnvoltCritLimitHighread-onlymandatoryThe high critical limit for the measured voltage. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.7ColumnvoltNonCritLimitHighread-onlymandatoryThe high non-critical limit for the measured voltage. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.8ColumnvoltNonRecovLimitLowread-onlymandatoryThe low non-recoverable limit for the measured voltage. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.9ColumnvoltCritLimitLowread-onlymandatoryThe low critical limit for the measured voltage. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.10ColumnvoltNonCritLimitLowread-onlymandatoryThe low non-critical limit for the measured voltage. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.2.2.1.11ColumnvoltHealthStatusread-onlymandatoryA description of the voltage component status.
1.3.6.1.4.1.2.3.51.3.1.3Nodefans
1.3.6.1.4.1.2.3.51.3.1.3.1ScalarfanNumberread-onlymandatoryThe present number of rows in the fan table.
1.3.6.1.4.1.2.3.51.3.1.3.2TablefanTablenot-accessiblemandatoryThis table contains fan information.
1.3.6.1.4.1.2.3.51.3.1.3.2.1RowfanEntrynot-accessiblemandatoryEach row contains parameters related to a fan.
1.3.6.1.4.1.2.3.51.3.1.3.2.1.1ColumnfanIndexread-onlymandatoryThis column is used to identify a particular fan.
1.3.6.1.4.1.2.3.51.3.1.3.2.1.2ColumnfanDescrread-onlymandatoryA description of the fan measurement channel.
1.3.6.1.4.1.2.3.51.3.1.3.2.1.3ColumnfanSpeedread-onlymandatoryFan speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero.…
1.3.6.1.4.1.2.3.51.3.1.3.2.1.4ColumnfanNonRecovLimitHighread-onlymandatoryThe high non-recoverable limit for the measured fan. If the measured value falls above this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.3.2.1.5ColumnfanCritLimitHighread-onlymandatoryThe high critical limit for the measured fan. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.3.2.1.6ColumnfanNonCritLimitHighread-onlymandatoryThe high non-critical limit for the measured fan. If the measured value rises above this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.3.2.1.7ColumnfanNonRecovLimitLowread-onlymandatoryThe low non-recoverable limit for the measured fan. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.3.2.1.8ColumnfanCritLimitLowread-onlymandatoryThe low critical limit for the measured fan. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.3.2.1.9ColumnfanNonCritLimitLowread-onlymandatoryThe low non-critical limit for the measured fan. If the measured value falls below this limit a trap is sent.
1.3.6.1.4.1.2.3.51.3.1.3.2.1.10ColumnfanHealthStatusread-onlymandatoryA description of the fan component status.
1.3.6.1.4.1.2.3.51.3.1.4NodesystemHealth
1.3.6.1.4.1.2.3.51.3.1.4.1ScalarsystemHealthStatread-onlymandatoryIndicates status of system health for the system in which the IMM resides. Value of 'nonRecoverable' indicates a severe error has occurred and the system may n…
1.3.6.1.4.1.2.3.51.3.1.4.2TablesystemHealthSummaryTablenot-accessiblemandatoryTable of System Health summary. Contains more detailed information about the reasons for the overall system health status.
1.3.6.1.4.1.2.3.51.3.1.4.2.1RowsystemHealthSummaryEntrynot-accessiblemandatorySystem Health Summary entry
1.3.6.1.4.1.2.3.51.3.1.4.2.1.1ColumnsystemHealthSummaryIndexread-onlymandatorySystem health summary index.
1.3.6.1.4.1.2.3.51.3.1.4.2.1.2ColumnsystemHealthSummarySeverityread-onlymandatorySystem health summary severity.
1.3.6.1.4.1.2.3.51.3.1.4.2.1.3ColumnsystemHealthSummaryDescriptionread-onlymandatorySystem health summary description.
1.3.6.1.4.1.2.3.51.3.1.5NodevpdInformation
1.3.6.1.4.1.2.3.51.3.1.5.1TableimmVpdTablenot-accessiblemandatoryTable of IMM VPD.
1.3.6.1.4.1.2.3.51.3.1.5.1.1RowimmVpdEntrynot-accessiblemandatoryiMBC VPD entry.
1.3.6.1.4.1.2.3.51.3.1.5.1.1.1ColumnimmVpdIndexread-onlymandatoryIMM VPD index.
1.3.6.1.4.1.2.3.51.3.1.5.1.1.2ColumnimmVpdTyperead-onlymandatoryIMM VPD Type. Indicates either Bios or Diag or spFimware VPD
1.3.6.1.4.1.2.3.51.3.1.5.1.1.3ColumnimmVpdVersionStringread-onlymandatoryIMM VPD Version Number of the software(Bios/Diag/spFirmware). For IMM2 the string contains both the Build ID and the Version Number, for example, like '1AOO3A …
1.3.6.1.4.1.2.3.51.3.1.5.1.1.4ColumnimmVpdReleaseDateread-onlymandatoryIMM VPD Release Date of when the software(Bios/Diag/spFirmware) was released.
1.3.6.1.4.1.2.3.51.3.1.5.2NodemachineVpd
1.3.6.1.4.1.2.3.51.3.1.5.2.1NodemachineLevelVpd
1.3.6.1.4.1.2.3.51.3.1.5.2.1.1ScalarmachineLevelVpdMachineTyperead-onlymandatoryMachine type VPD information.
1.3.6.1.4.1.2.3.51.3.1.5.2.1.2ScalarmachineLevelVpdMachineModelread-onlymandatoryMachine model VPD information.
1.3.6.1.4.1.2.3.51.3.1.5.2.1.3ScalarmachineLevelSerialNumberread-onlymandatoryMachine serial number VPD information.
1.3.6.1.4.1.2.3.51.3.1.5.2.1.4ScalarmachineLevelUUIDread-onlymandatoryMachine UUID(Universal Unique ID information).
1.3.6.1.4.1.2.3.51.3.1.5.2.1.5ScalarmachineLevelProductNameread-onlymandatoryMachine Product Name (e.g. System x3650 M2).
1.3.6.1.4.1.2.3.51.3.1.5.17TablesystemComponentLevelVpdTablenot-accessiblemandatoryTable of the system component hardware VPD information. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.17.1RowsystemComponentLevelVpdEntrynot-accessiblemandatorySystem component hardware VPD entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.17.1.1ColumncomponentLevelVpdIndexread-onlymandatorySystem component level VPD index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.17.1.2ColumncomponentLevelVpdFruNumberread-onlymandatorySystem component level VPD FRU number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.17.1.3ColumncomponentLevelVpdFruNameread-onlymandatorySystem component level VPD FRU name. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.17.1.4ColumncomponentLevelVpdSerialNumberread-onlymandatorySystem component level VPD serial number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.17.1.5ColumncomponentLevelVpdManufacturingIdread-onlymandatorySystem component level VPD manufacturing ID. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.18TablesystemComponentLevelVpdTrackingTablenot-accessiblemandatoryTable of system component hardware VPD tracking activity log. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.18.1RowsystemComponentLevelVpdTrackingEntrynot-accessiblemandatorySystem component hardware VPD tracking activity log entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.18.1.1ColumncomponentLevelVpdTrackingIndexread-onlymandatorySystem component level VPD tracking activity log index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.18.1.2ColumncomponentLevelVpdTrackingFruNumberread-onlymandatorySystem component level VPD tracking activity log FRU number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.18.1.3ColumncomponentLevelVpdTrackingFruNameread-onlymandatorySystem component level VPD tracking activity log FRU name. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.18.1.4ColumncomponentLevelVpdTrackingSerialNumberread-onlymandatorySystem component level VPD tracking activity log serial number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.18.1.5ColumncomponentLevelVpdTrackingManufacturingIdread-onlymandatorySystem component level VPD tracking activity log manufacturing ID. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.18.1.6ColumncomponentLevelVpdTrackingActionread-onlymandatorySystem component level VPD tracking activity log action(added/removed). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.18.1.7ColumncomponentLevelVpdTrackingTimestampread-onlymandatorySystem component level VPD tracking activity log timestanp. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.19TablehostMACAddressTablenot-accessiblemandatoryTable of MAC addresses of the host NICs. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.1.5.19.1RowhostMACAddressEntrynot-accessiblemandatoryHost MAC address entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.1.5.19.1.1ColumnhostMACAddressIndexread-onlymandatoryHost MAC address index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.19.1.2ColumnhostMACAddressDescriptionread-onlymandatoryDescription of the MAC Address entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.19.1.3ColumnhostMACAddressread-onlymandatoryHost MAC address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX View as a table and not as i…
1.3.6.1.4.1.2.3.51.3.1.5.20TablesystemCPUVpdTablenot-accessiblemandatoryTable of the system CPU VPD information. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1RowsystemCPUVpdEntrynot-accessiblemandatorySystem CPU VPD entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.1ColumncpuVpdIndexread-onlymandatorySystem CPU level VPD index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.2ColumncpuVpdDescriptionread-onlymandatorySystem CPU Description. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.3ColumncpuVpdSpeedread-onlymandatorySystem cpu speed in MHz. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.4ColumncpuVpdIdentifierread-onlymandatorySystem CPU Identifier. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.5ColumncpuVpdTyperead-onlymandatorySystem cpu Type. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.6ColumncpuVpdFamilyread-onlymandatorySystem cpu Family. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.7ColumncpuVpdCoresread-onlymandatorySystem cpu number of cores. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.8ColumncpuVpdThreadsread-onlymandatorySystem cpu number of threads. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.9ColumncpuVpdVoltageread-onlymandatorySystem cpu voltage in millivolts (1125 = 1.125 volts). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.10ColumncpuVpdDataWidthread-onlymandatorySystem cpu data width in bits. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.11ColumncpuVpdHealthStatusread-onlymandatorySystem cpu health status. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.20.1.12ColumncpuVpdCpuModelread-onlymandatorySystem cpu model. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21TablesystemMemoryVpdTablenot-accessiblemandatoryTable of the system Memory VPD information. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1RowsystemMemoryVpdEntrynot-accessiblemandatorySystem Memory VPD entry. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.1ColumnmemoryVpdIndexread-onlymandatorySystem Memory level VPD index. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.2ColumnmemoryVpdDescriptionread-onlymandatorySystem memory Description (e.g. DIMM 1). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.3ColumnmemoryVpdPartNumberread-onlymandatorySystem Memory Part Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.4ColumnmemoryVpdFRUSerialNumberread-onlymandatorySystem memory Serial Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.5ColumnmemoryVpdManufactureDateread-onlymandatorySystem memory Manufacture Date in week/year format (e.g. 3609). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.6ColumnmemoryVpdTyperead-onlymandatorySystem memory Type (e.g. DDR III SDRAM). View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.7ColumnmemoryVpdSizeread-onlymandatorySystem memory size in GigaBytes. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.8ColumnmemoryHealthStatusread-onlymandatoryA description of the memory component status.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.9ColumnmemoryConfigSpeedread-onlymandatorySystem configured memory clock speed in MHz. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.5.21.1.10ColumnmemoryRatedSpeedread-onlymandatorySystem rated memory clock speed in MB/s. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.6Nodeusers
1.3.6.1.4.1.2.3.51.3.1.6.1NodeimmUsers
1.3.6.1.4.1.2.3.51.3.1.6.1.1TablecurrentlyLoggedInTablenot-accessiblemandatoryTable of IMM users currently logged in.
1.3.6.1.4.1.2.3.51.3.1.6.1.1.1RowcurrentlyLoggedInEntrynot-accessiblemandatoryIMM users currently logged in entries.
1.3.6.1.4.1.2.3.51.3.1.6.1.1.1.1ColumncurrentlyLoggedInEntryIndexread-onlymandatoryIndex for IMM users currently logged in.
1.3.6.1.4.1.2.3.51.3.1.6.1.1.1.2ColumncurrentlyLoggedInEntryUserIdread-onlymandatoryName for IMM users currently logged in.
1.3.6.1.4.1.2.3.51.3.1.6.1.1.1.3ColumncurrentlyLoggedInEntryAccMethodread-onlymandatoryAccess method for IMM users currently logged in.
1.3.6.1.4.1.2.3.51.3.1.8Nodeleds
1.3.6.1.4.1.2.3.51.3.1.8.1ScalaridentityLEDread-writemandatoryIndicates whether the front panel identity LED is on,off, or blinking and allows user to change it.
1.3.6.1.4.1.2.3.51.3.1.8.2TableallLEDsTablenot-accessiblemandatoryTable of LEDs detailed information.
1.3.6.1.4.1.2.3.51.3.1.8.2.1RowallLEDsEntrynot-accessiblemandatoryLEDs Details entry
1.3.6.1.4.1.2.3.51.3.1.8.2.1.1ColumnledIndexread-onlymandatoryThe LED index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.1.8.2.1.2ColumnledIdentifierread-onlymandatoryThe unique identifier for this LED For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.1.8.2.1.4ColumnledLabelread-onlymandatoryText label for a LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.1.8.2.1.5ColumnledStateread-onlymandatoryText description which denotes color or on/off/blink state for a LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.1.8.2.1.6ColumnledColorread-onlymandatoryColor of this LED. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.1.8.3ScalarinformationLEDread-writemandatoryIndicates whether the front panel Information LED is on,off, or blinking and allows user to change it. The only value the user is allowed to enter is 0 for off…
1.3.6.1.4.1.2.3.51.3.1.9NodeosFailureCapture
1.3.6.1.4.1.2.3.51.3.1.9.1ScalarosFailureCaptureTftpServerread-writemandatoryTo save the OS Failure screen if one has been captured, set the IP address or host name of the TFTP server where the file should be transferred. The address mu…
1.3.6.1.4.1.2.3.51.3.1.9.2ScalarosFailureCaptureFileNameread-writemandatoryFile name of the saved capture file on the target system.
1.3.6.1.4.1.2.3.51.3.1.9.3ScalarosFailureCaptureSaveStartread-writemandatoryStart saving the configuration file to the specified target file and system. The file will exist if the OS Hang or OS Loader watchdog is enabled and been tripp…
1.3.6.1.4.1.2.3.51.3.1.9.4ScalarosFailureCaptureSaveStatusread-onlymandatoryGet the status of the last save operation which was initiated through SNMP method. Returns nocapture(2) if there is no OS Failure capture screen to save.
1.3.6.1.4.1.2.3.51.3.1.10NodefuelGauge
1.3.6.1.4.1.2.3.51.3.1.10.1NodefuelGaugeInformation
1.3.6.1.4.1.2.3.51.3.1.10.1.1ScalarfuelGaugePowerCappingPolicySettingread-writemandatoryPower Capping Policy. No Power Limit - The maximum power limit will be determined by the active Power Redundancy policy. Static Power Limit - Sets the overall …
1.3.6.1.4.1.2.3.51.3.1.10.1.2ScalarfuelGaugeStaticPowerPcapSoftMinread-onlymandatoryThis field displays power capping soft minimum value.
1.3.6.1.4.1.2.3.51.3.1.10.1.3ScalarfuelGaugeStaticPowerPcapMinread-onlymandatoryThis field displays power capping minimum value.
1.3.6.1.4.1.2.3.51.3.1.10.1.4ScalarfuelGaugeStaticPowerPcapCurrentSettingread-writemandatoryThis field is used to display or set the current power capping value.
1.3.6.1.4.1.2.3.51.3.1.10.1.5ScalarfuelGaugeStaticPowerPcapMaxread-onlymandatoryThis field displays power capping maximum value.
1.3.6.1.4.1.2.3.51.3.1.10.1.6ScalarfuelGaugeStaticPowerPcapModeread-writemandatoryThis field is used to display or set the all Power Cap settings to AC or DC.
1.3.6.1.4.1.2.3.51.3.1.10.1.7ScalarfuelGaugeSystemMaxPowerread-onlymandatoryThis field displays the system maximum power available value.
1.3.6.1.4.1.2.3.51.3.1.10.1.8ScalarfuelGaugePowerRemainingread-onlymandatoryThis field displays power remaining value.
1.3.6.1.4.1.2.3.51.3.1.10.1.9ScalarfuelGaugeTotalPowerAvaialbleread-onlymandatoryThis field displays the calculated total remaining power available value.
1.3.6.1.4.1.2.3.51.3.1.10.1.10ScalarfuelGaugeTotalPowerInUseread-onlymandatoryThis field displays total power in use value.
1.3.6.1.4.1.2.3.51.3.1.10.1.11ScalarfuelGaugeTotalThermalOutputread-onlymandatoryThis field displays the total thermal output value calculated from the AC power in use.
1.3.6.1.4.1.2.3.51.3.1.10.1.12ScalarfuelGaugePowerConsumptionCpuread-onlymandatoryThis field displays the power consumption of the processors.
1.3.6.1.4.1.2.3.51.3.1.10.1.13ScalarfuelGaugePowerConsumptionMemoryread-onlymandatoryThis field displays the power consumption of the memory.
1.3.6.1.4.1.2.3.51.3.1.10.1.15ScalarfuelGaugePowerConsumptionOtherread-onlymandatoryThis field displays the power consumption of other entities than processors and memory.
1.3.6.1.4.1.2.3.51.3.1.10.2NodepowerPolicyInformation
1.3.6.1.4.1.2.3.51.3.1.10.2.1TablepowerPolicyTablenot-accessiblemandatoryTable of Power Policy information for all power domains. Reading this table information about the available power policies that can be configured and which is …
1.3.6.1.4.1.2.3.51.3.1.10.2.1.1RowpowerPolicyEntrynot-accessiblemandatoryPower Policy Entry
1.3.6.1.4.1.2.3.51.3.1.10.2.1.1.1ColumnpowerPolicyIndexread-onlymandatoryThe unique idenitifier of a row in the powerPolicyTable.
1.3.6.1.4.1.2.3.51.3.1.10.2.1.1.2ColumnpowerPolicyNameread-onlymandatoryThe short name of the power policy. The following are the possible names and their detailed description: Power Module Redundancy Intended for a single AC power…
1.3.6.1.4.1.2.3.51.3.1.10.2.1.1.3ColumnpowerPolicyPwrSupplyFailureLimitread-onlymandatoryThe maximum number of power supplies that can fail in a chassis while still providing redundancy.
1.3.6.1.4.1.2.3.51.3.1.10.2.1.1.4ColumnpowerPolicyMaxPowerLimitread-onlymandatoryThe maximum power available (in watts), based on the number of power modules and the Power Management Policy setting.
1.3.6.1.4.1.2.3.51.3.1.10.2.1.1.5ColumnpowerPolicyEstimatedUtilizationread-onlymandatoryThe estimated utilization (as a percentage) based on current power usage.
1.3.6.1.4.1.2.3.51.3.1.10.2.1.1.6ColumnpowerPolicyActivateread-writemandatoryWhen read, this object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain…
1.3.6.1.4.1.2.3.51.3.1.10.3NodepowerPowerTrending
1.3.6.1.4.1.2.3.51.3.1.10.3.1ScalarpowerTrendingPeriodread-writemandatorySpecify time period for power domain 1 power trending information table view. NOTE: This time period should be configured before displaying the following Power…
1.3.6.1.4.1.2.3.51.3.1.10.3.2ScalarpowerTrendingPowerTyperead-writemandatoryThis field is used to display or set the power type displayed in the Power Trending Table.
1.3.6.1.4.1.2.3.51.3.1.10.3.3TablepowerTrendingSampleTablenot-accessiblemandatoryTable of Power Domain 1 Power Trending Information.
1.3.6.1.4.1.2.3.51.3.1.10.3.3.1RowpowerTrendingSampleEntrynot-accessiblemandatoryPower Domain 1 Power Trending Sample entry.
1.3.6.1.4.1.2.3.51.3.1.10.3.3.1.1ColumnpowerTrendingSampleIndexread-onlymandatoryPower Trending Sample Table Index.
1.3.6.1.4.1.2.3.51.3.1.10.3.3.1.2ColumnpowerTrendingSampleTimeStampread-onlymandatoryPower Trending Sample Table Timestamp.
1.3.6.1.4.1.2.3.51.3.1.10.3.3.1.3ColumnpowerTrendingSampleAveread-onlymandatoryPower Trending Table Average Power.
1.3.6.1.4.1.2.3.51.3.1.10.3.3.1.4ColumnpowerTrendingSampleMinread-onlymandatoryPower Trending Table Minimum Power.
1.3.6.1.4.1.2.3.51.3.1.10.3.3.1.5ColumnpowerTrendingSampleMaxread-onlymandatoryPower Trending Table Maximum Power.
1.3.6.1.4.1.2.3.51.3.1.11NodepowerModule
1.3.6.1.4.1.2.3.51.3.1.11.1ScalarpowerNumberread-onlymandatoryThe present number of rows in the power module table.
1.3.6.1.4.1.2.3.51.3.1.11.2TablepowerTablenot-accessiblemandatoryThis table contains power inventory information.
1.3.6.1.4.1.2.3.51.3.1.11.2.1RowpowerEntrynot-accessiblemandatoryEach row contains parameters related to a power module inventory channel.
1.3.6.1.4.1.2.3.51.3.1.11.2.1.1ColumnpowerIndexread-onlymandatoryThis column is used to identify a particular power module inventory channel.
1.3.6.1.4.1.2.3.51.3.1.11.2.1.2ColumnpowerFruNameread-onlymandatorypower module FRU name.
1.3.6.1.4.1.2.3.51.3.1.11.2.1.3ColumnpowerPartNumberread-onlymandatorypower module Part Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.11.2.1.4ColumnpowerFRUNumberread-onlymandatorypower module FRU Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.11.2.1.5ColumnpowerFRUSerialNumberread-onlymandatorypower module Serial Number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.1.11.2.1.6ColumnpowerHealthStatusread-onlymandatoryA description of the power module status.
1.3.6.1.4.1.2.3.51.3.1.12Nodedisks
1.3.6.1.4.1.2.3.51.3.1.12.1ScalardiskNumberread-onlymandatoryThe present number of rows in the disk module table.
1.3.6.1.4.1.2.3.51.3.1.12.2TablediskTablenot-accessiblemandatoryThis table contains disk inventory information.
1.3.6.1.4.1.2.3.51.3.1.12.2.1RowdiskEntrynot-accessiblemandatoryEach row contains parameters related to a disk module inventory channel.
1.3.6.1.4.1.2.3.51.3.1.12.2.1.1ColumndiskIndexread-onlymandatoryThis column is used to identify a particular disk module inventory channel.
1.3.6.1.4.1.2.3.51.3.1.12.2.1.2ColumndiskFruNameread-onlymandatorydisk module FRU name.
1.3.6.1.4.1.2.3.51.3.1.12.2.1.3ColumndiskHealthStatusread-onlymandatoryA description of the disk module status.
1.3.6.1.4.1.2.3.51.3.1.13NodelocalStorage
1.3.6.1.4.1.2.3.51.3.1.13.1Noderaid
1.3.6.1.4.1.2.3.51.3.1.13.1.1ScalarraidOOBCapableread-onlymandatoryIf raidOOBCapable is disabled, all the RAID information is not available.
1.3.6.1.4.1.2.3.51.3.1.13.1.2TableraidControllerTablenot-accessiblemandatoryTable of Local Storage RAID Controller information.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1RowraidControllerEntrynot-accessiblemandatoryRAID Controller Entry.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.1ColumncontrollerIndexread-onlymandatoryThis column is used to identify a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.3ColumnctrlVPDProdNameread-onlymandatoryThe Product Name of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.4ColumnctrlFWPkgVersionread-onlymandatoryThe Firmware Package Version of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.5ColumnctrlBatBCKread-onlymandatoryWhether Battery Backup of a particular RAID controller is installed.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.6ColumnctrlVPDManufactureread-onlymandatoryThe Manufacture of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.7ColumnctrlVPDUUIDread-onlymandatoryThe Device ID (UUID) of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.8ColumnctrlVPDMachineTyperead-onlymandatoryThe Model Type/Model of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.9ColumnctrlVPDModelread-onlymandatoryThe Model Type/Model of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.10ColumnctrlVPDSerialNoread-onlymandatoryThe Serial Number of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.11ColumnctrlVPDFRUNoread-onlymandatoryThe FRU Number of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.12ColumnctrlVPDPartNoread-onlymandatoryThe Part Number of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.13ColumnctrlCacheMdlStatusread-onlymandatoryThe Cache Model Status of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.14ColumnctrlCacheMdlMemSizeread-onlymandatoryThe Cache Model Memory Size of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.15ColumnctrlCacheMdlSerialNoread-onlymandatoryThe Cache Model Serial Number of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.16ColumnctrlPCISlotNoread-onlymandatoryThe PCI Slot Number of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.17ColumnctrlPCIBusNoread-onlymandatoryThe PCI Bus Number of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.18ColumnctrlPCIDevNoread-onlymandatoryThe PCI Device Number of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.19ColumnctrlPCIFuncNoread-onlymandatoryThe PCI Function Number of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.20ColumnctrlPCIDevIDread-onlymandatoryThe PCI Device ID of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.21ColumnctrlPCISubDevIDread-onlymandatoryThe PCI Subsystem Device ID of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.22ColumnctrlBatBCKProdNameread-onlymandatoryThe Product Name of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.23ColumnctrlBatBCKManufactureread-onlymandatoryThe Manufacture of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.24ColumnctrlBatBCKStatusread-onlymandatoryThe Status of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.25ColumnctrlBatBCKTyperead-onlymandatoryThe Battery Type of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.26ColumnctrlBatBCKChemread-onlymandatoryThe Chemistry of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.27ColumnctrlBatBCKSerialNoread-onlymandatoryThe Serial Number of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.28ColumnctrlBatBCKChgCapread-onlymandatoryThe Charge Capacity of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.29ColumnctrlBatBCKFirmwareread-onlymandatoryThe Firmware Info of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.30ColumnctrlBatBCKDgnVoltageread-onlymandatoryThe Designed Voltage of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.31ColumnctrlBatBCKVoltageread-onlymandatoryThe Voltage of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.32ColumnctrlBatCurrentread-onlymandatoryThe Current of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.33ColumnctrlBatBCKDgnChgCapread-onlymandatoryThe Design Charge Capacity of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.34ColumnctrlBatBCKCrtTempread-onlymandatoryThe Current degree Celsius temperature of Battery Backup of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.35ColumnctrlFWNamesread-onlymandatoryAll the Firmware Names of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.36ColumnctrlPortDetailsread-onlymandatoryAll the Port Details of a particular RAID controller, including Port Address and Port Controller Type.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.37ColumnctrlStoragepoolsread-onlymandatoryThe storage pools list of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.2.1.38ColumnctrlDrivesread-onlymandatoryThe Physical drives list of a particular RAID controller.
1.3.6.1.4.1.2.3.51.3.1.13.1.3TableraidDriveTablenot-accessiblemandatoryTable of Logic Storage RAID Drive information.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1RowraidDriveEntrynot-accessiblemandatoryRAID Drive Entry.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.1ColumndriveIndexread-onlymandatoryThis column is used to identify a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.3ColumndriveVPDProdNameread-onlymandatoryThe Product Name of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.4ColumndriveStateread-onlymandatoryThe State of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.5ColumndriveSlotNoread-onlymandatoryThe Slot No. of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.6ColumndriveDeviceIDread-onlymandatoryThe Device ID of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.7ColumndriveDiskTyperead-onlymandatoryThe Disk Type of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.8ColumndriveMediaTyperead-onlymandatoryThe Media Type of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.9ColumndriveSpeedread-onlymandatoryThe Speed of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.10ColumndriveCurTempread-onlymandatoryThe Current degree Celsius temperature of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.11ColumndriveHealthStatausread-onlymandatoryThe Health Status of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.12ColumndriveCapacityread-onlymandatoryThe Capacity of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.13ColumndriveVPDManufactureread-onlymandatoryThe Manufacture of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.14ColumndriveEnclosureIDread-onlymandatoryThe Enclosure ID of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.15ColumndriveVPDMachineTyperead-onlymandatoryThe Machine type of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.16ColumndriveVPDModelread-onlymandatoryThe Model of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.17ColumndriveVPDSerialNoread-onlymandatoryThe Serial No. of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.18ColumndriveVPDFRUNoread-onlymandatoryThe FRU No. of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.19ColumndriveVPDPartNoread-onlymandatoryThe Part No. of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.20ColumndriveFWNamesread-onlymandatoryAll the Firmware Names of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.21ColumndriveRotationRateread-onlymandatoryThe Rotation Rate of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.22ColumndriveMediaErrCntread-onlymandatoryThe Media Error Count of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.23ColumndriveOtherErrCntread-onlymandatoryThe Other Error Count of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.3.1.24ColumndrivePredFailCntread-onlymandatoryThe Predication Fail Count of a particular RAID drive.
1.3.6.1.4.1.2.3.51.3.1.13.1.4TableraidControllerFirmwareTablenot-accessiblemandatoryTable of Logic Storage RAID Controller Firmware information.
1.3.6.1.4.1.2.3.51.3.1.13.1.4.1RowraidFirmwareEntrynot-accessiblemandatoryRAID Firmware Entry.
1.3.6.1.4.1.2.3.51.3.1.13.1.4.1.3ColumnctrlNameread-onlymandatoryThe controller name of the firmwares.
1.3.6.1.4.1.2.3.51.3.1.13.1.5TableraidDriveFirmwareTablenot-accessiblemandatoryTable of Logic Storage RAID Drive Firmware information.
1.3.6.1.4.1.2.3.51.3.1.13.1.5.1RowraidDriveFirmwareEntrynot-accessiblemandatoryRAID Drive Firmware Entry.
1.3.6.1.4.1.2.3.51.3.1.13.1.5.1.1ColumnfirmwareIndexread-onlymandatoryThis column is used to identify a particular RAID Drive firmware.
1.3.6.1.4.1.2.3.51.3.1.13.1.5.1.2ColumnfwNameread-onlymandatoryThe Name of a particular RAID Drive firmware.
1.3.6.1.4.1.2.3.51.3.1.13.1.5.1.3ColumndriveNameread-onlymandatoryThe drive name of the firmwares.
1.3.6.1.4.1.2.3.51.3.1.13.1.5.1.4ColumnfwDescriptionread-onlymandatoryThe Description of a particular RAID Drive firmware.
1.3.6.1.4.1.2.3.51.3.1.13.1.5.1.5ColumnfwManufactureread-onlymandatoryThe Manufacture of a particular RAID Drive firmware.
1.3.6.1.4.1.2.3.51.3.1.13.1.5.1.6ColumnfwVersionread-onlymandatoryThe Version of a particular RAID Drive firmware.
1.3.6.1.4.1.2.3.51.3.1.13.1.5.1.7ColumnfwReleaseDateread-onlymandatoryThe Release Date of a particular RAID Drive firmware.
1.3.6.1.4.1.2.3.51.3.1.13.1.6TableraidStoragepoolTablenot-accessiblemandatoryTable of Logic Storage RAID Storagepool information.
1.3.6.1.4.1.2.3.51.3.1.13.1.6.1RowraidStoragepoolEntrynot-accessiblemandatoryRAID Storagepool Entry.
1.3.6.1.4.1.2.3.51.3.1.13.1.6.1.1ColumnstoragepoolIndexread-onlymandatoryThis column is used to identify a particular RAID storagepool.
1.3.6.1.4.1.2.3.51.3.1.13.1.6.1.2ColumnstoragepoolNameread-onlymandatoryThe name of a particular RAID storagepool.
1.3.6.1.4.1.2.3.51.3.1.13.1.6.1.4ColumnstoragepoolStateread-onlymandatoryThe RAID State of a particular RAID storagepool.
1.3.6.1.4.1.2.3.51.3.1.13.1.6.1.5ColumnstoragepoolCapacityread-onlymandatoryThe Capacity of a particular RAID storagepool, including total capacity and free capacity.
1.3.6.1.4.1.2.3.51.3.1.13.1.6.1.6ColumnstoragepoolVolsread-onlymandatoryThe volumes list of a particular RAID storagepool.
1.3.6.1.4.1.2.3.51.3.1.13.1.6.1.7ColumnstoragepoolDrivesread-onlymandatoryThe physical drives list of a particular RAID storagepool.
1.3.6.1.4.1.2.3.51.3.1.13.1.7TableraidVolumeTablenot-accessiblemandatoryTable of Logic Storage RAID Volume information.
1.3.6.1.4.1.2.3.51.3.1.13.1.7.1RowraidVolumeEntrynot-accessiblemandatoryRAID Volume Entry.
1.3.6.1.4.1.2.3.51.3.1.13.1.7.1.1ColumnvolumeIndexread-onlymandatoryThis column is used to identify a particular RAID volume.
1.3.6.1.4.1.2.3.51.3.1.13.1.7.1.2ColumnvolumeNameread-onlymandatoryThe Name of a particular RAID volume.
1.3.6.1.4.1.2.3.51.3.1.13.1.7.1.3ColumncontrollerNameread-onlymandatoryThe controller name of the volume.
1.3.6.1.4.1.2.3.51.3.1.13.1.7.1.4ColumnvolumeStatusread-onlymandatoryThe Status of a particular RAID volume.
1.3.6.1.4.1.2.3.51.3.1.13.1.7.1.5ColumnvolumeCapacityread-onlymandatoryThe Capacity of a particular RAID volume.
1.3.6.1.4.1.2.3.51.3.1.13.1.7.1.6ColumnvolumeStripSizeread-onlymandatoryThe strip size of the RAID volume.
1.3.6.1.4.1.2.3.51.3.1.13.1.7.1.7ColumnvolumeBootableread-onlymandatoryWhether the RAID volume is bootable.
1.3.6.1.4.1.2.3.51.3.1.13.2Nodeflashdimm
1.3.6.1.4.1.2.3.51.3.1.13.2.1ScalarfdNumberread-onlymandatoryThe present number of rows in the disk flashdimm table.
1.3.6.1.4.1.2.3.51.3.1.13.2.2TablefdTablenot-accessiblemandatoryThis table contains flashdimm inventory information.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1RowfdEntrynot-accessiblemandatoryEach row contains parameters related to a flashdimm module inventory channel.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.1ColumnfdIndexread-onlymandatoryThis column is used to identify a particular flashdimm module inventory channel.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.2ColumnfdFruNameread-onlymandatoryflashdimm module FRU name.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.3ColumnfdHealthStatusread-onlymandatoryA description of the flashdimm module health status.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.4ColumnfdOpStateread-onlymandatoryA description of the flashdimm module operation status.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.5ColumnfdCapacityread-onlymandatoryA description of the flashdimm module capacity.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.6ColumnfdModelTyperead-onlymandatoryA description of the flashdimm module type.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.7ColumnfdPartNumread-onlymandatoryA description of the flashdimm module part number.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.8ColumnfdFruSerialNumread-onlymandatoryA description of the flashdimm module serial number.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.9ColumnfdManufIDread-onlymandatoryA description of the flashdimm module manufacture id.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.10ColumnfdTempread-onlymandatoryA description of the flashdimm module temperature.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.11ColumnfdWarrWritesread-onlymandatoryA description of the flashdimm module warranty writes.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.12ColumnfdWriteEnduranceread-onlymandatoryA description of the flashdimm module write endurance.
1.3.6.1.4.1.2.3.51.3.1.13.2.2.1.13ColumnfdFwLevelread-onlymandatoryA description of the flashdimm module status.
1.3.6.1.4.1.2.3.51.3.1.14Nodeadapters
1.3.6.1.4.1.2.3.51.3.1.14.1ScalaradapterOOBCapableread-onlymandatoryIf adapterOOBCapable is disabled, all the adapter information is not available.
1.3.6.1.4.1.2.3.51.3.1.14.2TableadapterGenericTablenot-accessiblemandatoryTable of all adapters generic information
1.3.6.1.4.1.2.3.51.3.1.14.2.1RowadapterGenericEntrynot-accessiblemandatoryAdapters generic information entry.
1.3.6.1.4.1.2.3.51.3.1.14.2.1.1ColumnadapterGenericIndexread-onlymandatoryThis column is used to identify a particular PCI adapter.
1.3.6.1.4.1.2.3.51.3.1.14.2.1.3ColumnadapterSlotNoread-onlymandatoryThis Slot No. of a particular PCI adapter
1.3.6.1.4.1.2.3.51.3.1.14.2.1.4ColumnadapterLocationread-onlymandatoryThe Location of a particular PCI adapter.
1.3.6.1.4.1.2.3.51.3.1.14.2.1.5ColumnadapterCardInterfaceread-onlymandatoryThe Card Interface of a particular PCI adapter.
1.3.6.1.4.1.2.3.51.3.1.14.3TableadapterNetworkFunctionTablenot-accessiblemandatoryTable of Network Function information.
1.3.6.1.4.1.2.3.51.3.1.14.3.1RowadapterNetworkFunctionEntrynot-accessiblemandatoryNetwork function information entry.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.1ColumnnetworkAdapterIndexread-onlymandatoryThis column is used to identify a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.4ColumnnetworkVPDManufacturerread-onlymandatoryThe Manufacturer of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.5ColumnnetworkVPDUUIDread-onlymandatoryThe UUID of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.6ColumnnetworkVPDModelread-onlymandatoryThe Model of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.7ColumnnetworkVPDSerialNoread-onlymandatoryThe Serial No. of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.8ColumnnetworkVPDFRUNoread-onlymandatoryThe FRU No. of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.9ColumnnetworkVPDPartNoread-onlymandatoryThe Part No. of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.10ColumnnetworkFoDUIDread-onlymandatoryThe FoD UID of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.11ColumnnetworkSupportHotPlugread-onlymandatoryIndicates whether the network function supports hot plug.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.12ColumnnetworkPhysicalPortNumberread-onlymandatoryThe Physical Port Number of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.13ColumnnetworkMaxPortNumberread-onlymandatoryThe Max Port Number of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.14ColumnnetworkPortNumberread-onlymandatoryThe Port Number of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.15ColumnnetworkMaxDataWidthread-onlymandatoryThe Maximum Data Width in Gbps of a particular network funtion.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.16ColumnnetworkPackageTyperead-onlymandatoryThe Package Type of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.17ColumnnetworkPCIBusNoread-onlymandatoryThe PCI Bus No. of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.18ColumnnetworkPCIDevNoread-onlymandatoryThe PCI Device No. of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.19ColumnnetworkPCIFuncNoread-onlymandatoryThe PCI Function No. of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.20ColumnnetworkPCIVendorIdread-onlymandatoryThe PCI Vendor ID of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.21ColumnnetworkPCIDevIdread-onlymandatoryThe PCI Device ID of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.22ColumnnetworkPCIDevTyperead-onlymandatoryThe PCI Device Type of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.23ColumnnetworkPCIRevIdread-onlymandatoryThe PCI Revision ID of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.24ColumnnetworkPCISubVendorIdread-onlymandatoryThe PCI Subsystem Vendor ID of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.25ColumnnetworkPCISubDevIdread-onlymandatoryThe PCI Subsystem Device ID of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.3.1.26ColumnnetworkPCISlotDesignationread-onlymandatoryThe PCI Slot Designation of a particular network function.
1.3.6.1.4.1.2.3.51.3.1.14.4TableadapterNetworkPortTablenot-accessiblemandatoryTable of Ports of Network Function information.
1.3.6.1.4.1.2.3.51.3.1.14.4.1RowadapterNetworkPortEntrynot-accessiblemandatoryPorts of Network Function information entry.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.1ColumnportIndexread-onlymandatoryThis column is used to identify a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.2ColumnnetworkVPDProdNameread-onlymandatoryThe Product Name and PFA of the network function for this port and PFA is in HEX.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.3ColumnphyPortNoread-onlymandatoryThe Physical Port No. in the network function for this port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.4ColumnphyPortConnectorread-onlymandatoryThe Physical Port Connector Layout in the network function for this port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.5ColumnphyPortBurnedinAddressread-onlymandatoryThe Physical Permanent (burned-In) Address of a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.6ColumnportNoread-onlymandatoryThe Port No. of this network port in the network function.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.7ColumnportMaxDataSizeread-onlymandatoryThe Port Max Data Size of this network port in the network function.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.8ColumnportPermanentAddressread-onlymandatoryThe Permanent Address of a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.9ColumnportNetworkAddressread-onlymandatoryThe Network Address of a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.10ColumnportLinkTechnologyread-onlymandatoryThe Link Technology of a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.11ColumnportvNICModeread-onlymandatoryIf the logical port vNIC mode is Virtual Fabric mode, Switch Independent mode, or Unified Fabric Protocol mode, this column returns 1(enabled), otherwise, the …
1.3.6.1.4.1.2.3.51.3.1.14.4.1.12ColumnportMaxSpeedread-onlymandatoryThe Maximum Bandwidth in Gbps of a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.13ColumnportProtocolTyperead-onlymandatoryThe Protocol Type of a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.14ColumnportCurrentProtocolread-onlymandatoryThe Current Work Protocol of a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.15ColumnportFCoEPermanentAddressread-onlymandatoryThe FCoE Permanent Address of a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.16ColumnportFCoENetworkAddressread-onlymandatoryThe FCoE Network Address of a particular network port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.17ColumnportConnectionTyperead-onlymandatoryThe Connection Type of a particular network port if its current work protocol is FC or FCoE.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.18ColumnportRoleread-onlymandatoryThe Port Role of a particular network port if its current work protocol is FC or FCoE.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.19ColumnportTargetRelativePortNoread-onlymandatoryThe Target Relative Port No. of a particular network port if its current work protocol is FC or FCoE.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.20ColumnphyPortLinkStatusread-onlymandatoryThe Physical Port Link Status in the network function for this port.
1.3.6.1.4.1.2.3.51.3.1.14.4.1.21ColumnphyPortLinkSpeedread-onlymandatoryThe Physical Port Link Speed in the network function for this port.
1.3.6.1.4.1.2.3.51.3.1.14.5TableadapterGPUFunctionTablenot-accessiblemandatoryTable of GPU Function information.
1.3.6.1.4.1.2.3.51.3.1.14.5.1RowadapterGPUFunctionEntrynot-accessiblemandatoryGPU function information entry.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.1ColumngpuAdapterIndexread-onlymandatoryThis column is used to identify a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.4ColumngpuVPDManufacturerread-onlymandatoryThe Manufacturer of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.5ColumngpuVPDUUIDread-onlymandatoryThe UUID of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.6ColumngpuVPDModelread-onlymandatoryThe Model of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.7ColumngpuVPDSerialNoread-onlymandatoryThe Serial No. of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.8ColumngpuVPDFRUNoread-onlymandatoryThe FRU No. of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.9ColumngpuVPDPartNoread-onlymandatoryThe Part No. of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.10ColumngpuFoDUIDread-onlymandatoryThe FoD UID of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.11ColumngpuSupportHotPlugread-onlymandatoryIndicates whether the GPU function supports hot plug.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.12ColumngpuVideoMemorySizeread-onlymandatoryThe Video Memory Size of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.13ColumngpuVideoMemoryTyperead-onlymandatoryThe Video Memory Type of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.14ColumngpuChipNumberread-onlymandatoryThe Chip Number of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.15ColumngpuMaxDataWidthread-onlymandatoryThe Maximum Data Width in Gbps of a particular GPU funtion.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.16ColumngpuPackageTyperead-onlymandatoryThe Package Type of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.17ColumngpuPCIBusNoread-onlymandatoryThe PCI Bus No. of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.18ColumngpuPCIDevNoread-onlymandatoryThe PCI Device No. of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.19ColumngpuPCIFuncNoread-onlymandatoryThe PCI Function No. of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.20ColumngpuPCIVendorIdread-onlymandatoryThe PCI Vendor ID of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.21ColumngpuPCIDevIdread-onlymandatoryThe PCI Device ID of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.22ColumngpuPCIDevTyperead-onlymandatoryThe PCI Device Type of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.23ColumngpuPCIRevIdread-onlymandatoryThe PCI Revision ID of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.24ColumngpuPCISubVendorIdread-onlymandatoryThe PCI Subsystem Vendor ID of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.25ColumngpuPCISubDevIdread-onlymandatoryThe PCI Subsystem Device ID of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.5.1.26ColumngpuPCISlotDesignationread-onlymandatoryThe PCI Slot Designation of a particular GPU function.
1.3.6.1.4.1.2.3.51.3.1.14.6TableadapterGPUChipTablenot-accessiblemandatoryTable of Chips of GPU Function information.
1.3.6.1.4.1.2.3.51.3.1.14.6.1RowadapterGPUChipEntrynot-accessiblemandatoryGPU function chip information entry.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.1ColumnchipIndexread-onlymandatoryThis column is used to identify a particular GPU chip
1.3.6.1.4.1.2.3.51.3.1.14.6.1.2ColumngpuVPDProdNameread-onlymandatoryThe Product Name and PFA of the GPU function for this chip and PFA is in HEX.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.3ColumnchipNoread-onlymandatoryThe Index of the GPU chip in the GPU adapter.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.4ColumnchipNameread-onlymandatoryThe Name of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.5ColumnchipFamilyread-onlymandatoryThe Family Name of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.6ColumnchipManufacturerread-onlymandatoryThe Manufacturer of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.7ColumnchipCoresEnabledread-onlymandatoryIndicates whether enable cores of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.8ColumnchipMaxClockSpeedread-onlymandatoryThe Maximum Clock Speed in MHz of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.9ColumnchipExtBusClockSpeedread-onlymandatoryThe External Bus Clock Speed in MHz of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.10ColumnchipAddressWidthread-onlymandatoryThe Address Width of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.11ColumnchipDataWidthread-onlymandatoryThe Data Width of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.12ColumnchipFormFactorread-onlymandatoryThe Form Factor of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.13ColumnchipModelread-onlymandatoryThe Model of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.14ColumnchipSerialNoread-onlymandatoryThe Serial No. of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.15ColumnchipFRUNoread-onlymandatoryThe FRU No. of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.16ColumnchipPartNoread-onlymandatoryThe Part No. of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.6.1.17ColumnchipUniqueIDread-onlymandatoryThe Unique ID of a particular GPU chip.
1.3.6.1.4.1.2.3.51.3.1.14.7TableadapterRAIDFunctionTablenot-accessiblemandatoryTable of RAID Function information.
1.3.6.1.4.1.2.3.51.3.1.14.7.1RowadapterRAIDFunctionEntrynot-accessiblemandatoryRAID function information entry.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.1ColumnraidAdapterIndexread-onlymandatoryThis column is used to identify a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.2ColumnraidVPDProdNameread-onlymandatoryThe Product Name and PFA of a particular RAID function and PFA is in HEX.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.3ColumnadapterVPDProdNameread-onlymandatoryThe Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.4ColumnraidVPDManufacturerread-onlymandatoryThe Manufacturer of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.5ColumnraidVPDUUIDread-onlymandatoryThe UUID of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.6ColumnraidVPDModelread-onlymandatoryThe Model of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.7ColumnraidVPDSerialNoread-onlymandatoryThe Serial No. of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.8ColumnraidVPDFRUNoread-onlymandatoryThe FRU No. of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.9ColumnraidVPDPartNoread-onlymandatoryThe Part No. of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.10ColumnraidFoDUIDread-onlymandatoryThe FoD UID of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.11ColumnraidSupportHotPlugread-onlymandatoryIndicates whether the RAID function supports hot plug.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.12ColumnraidMaxDataWidthread-onlymandatoryThe Maximum Data Width in Gbps of a particular RAID funtion.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.13ColumnraidPackageTyperead-onlymandatoryThe Package Type of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.14ColumnraidPCIBusNoread-onlymandatoryThe PCI Bus No. of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.15ColumnraidPCIDevNoread-onlymandatoryThe PCI Device No. of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.16ColumnraidPCIFuncNoread-onlymandatoryThe PCI Function No. of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.17ColumnraidPCIVendorIdread-onlymandatoryThe PCI Vendor ID of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.18ColumnraidPCIDevIdread-onlymandatoryThe PCI Device ID of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.19ColumnraidPCIDevTyperead-onlymandatoryThe PCI Device Type of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.20ColumnraidPCIRevIdread-onlymandatoryThe PCI Revision ID of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.21ColumnraidPCISubVendorIdread-onlymandatoryThe PCI Subsystem Vendor ID of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.22ColumnraidPCISubDevIdread-onlymandatoryThe PCI Subsystem Device ID of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.7.1.23ColumnraidPCISlotDesignationread-onlymandatoryThe PCI Slot Designation of a particular RAID function.
1.3.6.1.4.1.2.3.51.3.1.14.8TableadapterFirmwareTablenot-accessiblemandatoryTable of PCI Function Firmware information.
1.3.6.1.4.1.2.3.51.3.1.14.8.1RowadapterFirmwareEntrynot-accessiblemandatoryAdapter Firmware Entry.
1.3.6.1.4.1.2.3.51.3.1.14.8.1.1ColumnadapterFwIndexread-onlymandatoryThis column is used to identify a particular function firmware.
1.3.6.1.4.1.2.3.51.3.1.14.8.1.2ColumnfunctionVPDProdNameread-onlymandatoryThe Product Name and PFA of a particular function for this firmware and PFA is in HEX.
1.3.6.1.4.1.2.3.51.3.1.14.8.1.3ColumnadapterFwNameread-onlymandatoryThe name of a particular PCI function firmware.
1.3.6.1.4.1.2.3.51.3.1.14.8.1.4ColumnadapterFwClassificationread-onlymandatoryThe classification of a particular PCI function firmware.
1.3.6.1.4.1.2.3.51.3.1.14.8.1.5ColumnadapterFwDescriptionread-onlymandatoryThe description of a particular PCI function firmware.
1.3.6.1.4.1.2.3.51.3.1.14.8.1.6ColumnadapterFwManufactureread-onlymandatoryThe manufacturer of a particular PCI function firmware.
1.3.6.1.4.1.2.3.51.3.1.14.8.1.7ColumnadapterFwVersionread-onlymandatoryThe version of a particular PCI function firmware.
1.3.6.1.4.1.2.3.51.3.1.14.8.1.8ColumnadapterFwReleaseDateread-onlymandatoryThe release date of a particular PCI function firmware.
1.3.6.1.4.1.2.3.51.3.1.14.8.1.9ColumnadapterFwSoftwareIDread-onlymandatoryThe Software ID of a particular PCI function firmware.
1.3.6.1.4.1.2.3.51.3.2NodeerrorLogs
1.3.6.1.4.1.2.3.51.3.2.1NodeeventLog
1.3.6.1.4.1.2.3.51.3.2.1.1TableeventLogTablenot-accessiblemandatoryTable of event logs. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.2.1.1.1RoweventLogEntrynot-accessiblemandatoryEvent log entries. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.2.1.1.1.1ColumneventLogIndexread-onlymandatoryEvent log index number. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.2.1.1.1.2ColumneventLogStringread-onlymandatoryContains a string of information to detail the event. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.2.1.1.1.3ColumneventLogSeverityread-onlymandatoryContains a information to detail the severity of the event. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.2.1.1.1.4ColumneventLogDateread-onlymandatoryThe Date of the Event occured. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.2.1.1.1.5ColumneventLogTimeread-onlymandatoryThe Time of the Event occured. View as a table and not as individual entries for consistent results.
1.3.6.1.4.1.2.3.51.3.2.1.3ScalareventLogClrwrite-onlymandatoryClear the event log.
1.3.6.1.4.1.2.3.51.3.2.1.4ScalareventLogTftpServerread-writemandatoryTo save the eventLog if it is not empty, set the IP address or host name of the TFTP server where the file should be transferred. The address must be entered i…
1.3.6.1.4.1.2.3.51.3.2.1.5ScalareventLogFileNameread-writemandatoryFile name of the saved log file on the target system.
1.3.6.1.4.1.2.3.51.3.2.1.6ScalareventLogSaveStartread-writemandatoryStart saving the eventLog file to the specified target file and system. Using execute will cause the SNMP client to wait for the save operation to complete. Us…
1.3.6.1.4.1.2.3.51.3.2.1.7ScalareventLogSaveStatusread-onlymandatoryGet the status of the last save operation which was initiated through SNMP method.
1.3.6.1.4.1.2.3.51.3.3NodeconfigureSP
1.3.6.1.4.1.2.3.51.3.3.1NoderemoteAccessConfig
1.3.6.1.4.1.2.3.51.3.3.1.1NodegeneralRemoteCfg
1.3.6.1.4.1.2.3.51.3.3.1.1.1ScalarremoteAlertRetryDelayread-writemandatoryNumber in seconds to delay between retries if sending a remote alert is unsuccessful.
1.3.6.1.4.1.2.3.51.3.3.1.1.2ScalarremoteAlertRetryCountread-writemandatoryNumber of additional times a remote alert will be retried if not succesfully sent. A value of zero indicates no retries will be attempted.
1.3.6.1.4.1.2.3.51.3.3.1.1.3ScalarremoteAlertEntryDelayread-writemandatoryNumber in seconds to delay between entries if sending a remote alert is unsuccessful.
1.3.6.1.4.1.2.3.51.3.3.1.1.4ScalarsnmpCriticalAlertsread-writemandatoryIf Enabled,criticalAlerts will be sent to SNMP, else critical alerts will not be sent.
1.3.6.1.4.1.2.3.51.3.3.1.1.5ScalarsnmpWarningAlertsread-writemandatoryIf Enabled,warningAlerts will be sent to SNMP , else warning alerts will not be sent.
1.3.6.1.4.1.2.3.51.3.3.1.1.6ScalarsnmpSystemAlertsread-writemandatoryIf Enabled,systemAlerts will be sent to SNMP , else system alerts will not be sent.
1.3.6.1.4.1.2.3.51.3.3.1.1.7ScalarremoteAccessTamperDelayread-writemandatoryNumber in minutes to prohibit a remote login attempt after more than 5 sequential login attempts have failed.
1.3.6.1.4.1.2.3.51.3.3.1.1.8ScalaruserAuthenticationMethodread-writemandatoryUse this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified …
1.3.6.1.4.1.2.3.51.3.3.1.1.9ScalarwebInactivityTimeoutread-writemandatoryUse this field to indicate how long, in minutes, the IMM subsystem will wait before disconnecting an inactive web session. Select the no timeout option to disa…
1.3.6.1.4.1.2.3.51.3.3.1.1.10NodesnmpAlertFilters
1.3.6.1.4.1.2.3.51.3.3.1.1.10.2ScalarsafSpTrapTempCread-writemandatoryCritical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.3ScalarsafSpTrapVoltCread-writemandatoryCritical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.4ScalarsafSpTrapPowerCread-writemandatoryCritical Alert: Power failure.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.5ScalarsafSpTrapHdCread-writemandatoryCritical Alert: Hard disk drive failure.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.6ScalarsafSpTrapFanCread-writemandatoryCritical Alert: Single Fan failure.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.7ScalarsafSpTrapIhcCread-writemandatoryCritical Alert: Incompatible hardware configuration.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.8ScalarsafSpTrapCPUCread-writemandatoryCritical Alert: CPU Error.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.9ScalarsafSpTrapMemoryCread-writemandatoryCritical Alert: Memory Error.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.10ScalarsafSpTrapRdpsCread-writemandatoryCritical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.11ScalarsafSpTrapHardwareCread-writemandatoryCritical Alert: Other Failure - refer to Message ID for specific condition.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.12ScalarsafSpTrapRdpsNread-writemandatoryNon-Critical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.13ScalarsafSpTrapTempNread-writemandatoryNon-Critical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.14ScalarsafSpTrapVoltNread-writemandatoryNon-Critical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.15ScalarsafSpTrapPowerNread-writemandatoryNon-Critical Alert: Power.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.16ScalarsafSpTrapFanNread-writemandatoryNon-Critical Alert: Fan Error.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.17ScalarsafSpTrapCPUNread-writemandatoryNon-Critical Alert: Memory Error.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.18ScalarsafSpTrapMemoryNread-writemandatoryNon-Critical Alert: Memory Error.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.19ScalarsafSpTrapHardwareNread-writemandatoryNon-Critical Alert: Warning - refer to Message ID for specific condition.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.20ScalarsafSpTrapRLoginread-writemandatorySev-Off Alert: Event Remote Login.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.21ScalarsafSpTrapOsToSread-writemandatorySystem Alert: OS Timeout value exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.22ScalarsafSpTrapAppSread-writemandatorySystem Alert: Application Alert. Refer to Message ID for specific condition.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.23ScalarsafSpTrapPowerSread-writemandatorySystem Alert: Power on or off.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.24ScalarsafSpTrapBootSread-writemandatorySystem Alert: System Boot Failure.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.25ScalarsafSpTrapLdrToSread-writemandatorySystem Alert: OS Loader Timeout.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.26ScalarsafSpTrapPFASread-writemandatorySystem Alert: Predictive Failure Analysis(PFA) information.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.27ScalarsafSpTrapSysLogSread-writemandatorySystem Alert: System Log 75% full.
1.3.6.1.4.1.2.3.51.3.3.1.1.10.28ScalarsafSpTrapNwChangeSread-writemandatorySystem Alert: Network change notification.
1.3.6.1.4.1.2.3.51.3.3.1.1.20NodecustomSecuritySettings
1.3.6.1.4.1.2.3.51.3.3.1.1.20.1ScalarloginPasswordRequiredread-writemandatoryIf enabled, all users require a login password to access the IMM via the CLI and Web interfaces. The default value is disabled.
1.3.6.1.4.1.2.3.51.3.3.1.1.20.2ScalarpasswordExpirationPeriodread-writemandatoryThe number of days before login passwords expire. The minimum value is 1 day and the maximum value is 365 days. The default value is 90 days. A value of 0 disa…
1.3.6.1.4.1.2.3.51.3.3.1.1.20.3ScalarminimumPasswordReuseCycleread-writemandatoryThe number of unique passwords a user must choose before reusing a password. The default value is none.
1.3.6.1.4.1.2.3.51.3.3.1.1.20.4ScalarcomplexPasswordRulesEnforcedread-writemandatoryIf enabled, password should contains at least one numeric and one alphabetic character.
1.3.6.1.4.1.2.3.51.3.3.1.1.20.5ScalarminimumPasswordLengthread-writemandatoryThe required minimum number of characters in the new password. The default value is 8. A SET of this object is ignored until the complexPasswordRules option is…
1.3.6.1.4.1.2.3.51.3.3.1.1.20.6ScalardefaultAdminPasswordExpiredread-writemandatoryIf enabled, the factory default 'USERID' account password must be changed on next login. The default value is disabled.
1.3.6.1.4.1.2.3.51.3.3.1.1.20.7ScalarminimumDiffCharsPasswordread-writemandatoryThe required minimum number of characters in the new password different from the previous password. The default value is 2. A SET of this object is ignored unt…
1.3.6.1.4.1.2.3.51.3.3.1.1.20.8ScalarchangePasswordFirstAccessread-writemandatoryIf enabled, the login user will be forced to change their password on the first access after the account has been established or on the first access after an a…
1.3.6.1.4.1.2.3.51.3.3.1.1.20.9ScalaraccountLockoutPeriodread-writemandatoryThe period of time in minutes that a user is locked out after the maximum number of login failures was reached. The minimum value is is 1 minute and the maximu…
1.3.6.1.4.1.2.3.51.3.3.1.1.20.10ScalarmaxLoginFailuresread-writemandatoryThe maximum number of login failures before a user account is locked. A value of 0 disables this option. The default value is 5.
1.3.6.1.4.1.2.3.51.3.3.1.1.20.11ScalarpasswordChangeIntervalread-writemandatoryA minimum period of time that user is not able to change their own password. The range of acceptable values will be from 0 to 240 (or 10 days). A value of 0 di…
1.3.6.1.4.1.2.3.51.3.3.1.2NodeserialPortCfg
1.3.6.1.4.1.2.3.51.3.3.1.2.1ScalarportBaudread-writemandatoryBaud rate for the serial port.
1.3.6.1.4.1.2.3.51.3.3.1.2.2ScalarportParityread-writemandatoryParity setting for the serial port.
1.3.6.1.4.1.2.3.51.3.3.1.2.3NodeserialRedirect
1.3.6.1.4.1.2.3.51.3.3.1.2.3.1ScalarenterCLIkeySeqread-writemandatoryThis is the keystroke sequence used to enter the CLI. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequen…
1.3.6.1.4.1.2.3.51.3.3.1.2.4ScalarportStopBitsread-writemandatoryNumber of stop bits for the serial port.
1.3.6.1.4.1.2.3.51.3.3.1.2.18ScalarportCLImoderead-writemandatoryUse this field to select the CLI (command line interface) mode for this port. The CLI mode disablies serial redirect, or pecifies the type of keystroke sequenc…
1.3.6.1.4.1.2.3.51.3.3.1.3NoderemoteAlertIds
1.3.6.1.4.1.2.3.51.3.3.1.3.1TableremoteAlertIdsTablenot-accessiblemandatoryTable of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1RowremoteAlertIdsEntrynot-accessiblemandatoryRemote alert entries.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.1ColumnremoteAlertIdEntryIndexread-onlymandatoryIndex for remote alert entry.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.2ColumnremoteAlertIdEntryStatusread-writemandatoryIf enabled alerts will be sent to this alert recipient else alerts will not be sent.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.3ColumnremoteAlertIdEntryNameread-writemandatoryA null terminated string that contains a text description of this entry.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.4ColumnremoteAlertIdEmailAddrread-writemandatoryA null terminated string that contains a E-Mail Address. For example 'jeb@us.lenovo.com'. Used only for a E-mail over Lan.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.5ColumnremoteAlertIdEntryCriticalAlertread-writemandatoryIf Enabled,criticalAlerts will be sent to this remote alert receipient,else critical alerts will not be sent.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.6ColumnremoteAlertIdEntryWarningAlertread-writemandatoryIf Enabled,warningAlerts will be sent to this remote alert receipient,else warningAlerts will not be sent.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.7ColumnremoteAlertIdEntrySystemAlertread-writemandatoryIf Enabled,systemAlerts will be sent to this remote alert receipient,else systemAlerts will not be sent.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.8ColumnremoteAlertIdEntryAuditAlertread-writemandatoryIf Enabled,systemAlerts will be sent to this remote alert receipient,else systemAlerts will not be sent.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.9ColumnremoteAlertIdEntryAttachmentsToEmailAlertsread-writemandatoryIndicates if the event log should be attached to a email alert.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.10ColumnremoteAlertIdEntrySyslogPortAssignmentread-writemandatorySyslog port number.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.11ColumnremoteAlertIdEntrySyslogHostnameread-writemandatorySyslog hostname or IP address.
1.3.6.1.4.1.2.3.51.3.3.1.3.1.1.12ColumnremoteAlertIdEntryTyperead-writemandatoryAlert recipient type.
1.3.6.1.4.1.2.3.51.3.3.1.3.2TableremoteAlertFiltersTablenot-accessiblemandatoryTable of Alert Filters. The entries (rows) in this table correspond 1-1 with the entries in the remoteAlertIdsTable. They are correlated by index.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1RowremoteAlertFiltersEntrynot-accessiblemandatoryRemote Filters entries.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.1ColumnrafIndexread-onlymandatoryIndex for User Authority Level entry.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.2ColumnrafSpTrapTempCread-writemandatoryCritical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.3ColumnrafSpTrapVoltCread-writemandatoryCritical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.4ColumnrafSpTrapPowerCread-writemandatoryCritical Alert: Power failure.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.5ColumnrafSpTrapHdCread-writemandatoryCritical Alert: Hard disk drive failure.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.6ColumnrafSpTrapFanCread-writemandatoryCritical Alert: Single Fan failure.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.7ColumnrafSpTrapIhcCread-writemandatoryCritical Alert: Incompatible hardware configuration.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.8ColumnrafSpTrapCPUCread-writemandatoryCritical Alert: CPU Error.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.9ColumnrafSpTrapMemoryCread-writemandatoryCritical Alert: Memory Error.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.10ColumnrafSpTrapRdpsCread-writemandatoryCritical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.11ColumnrafSpTrapHardwareCread-writemandatoryCritical Alert: Other Failure - refer to Message ID for specific condition.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.12ColumnrafSpTrapRdpsNread-writemandatoryNon-Critical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.13ColumnrafSpTrapTempNread-writemandatoryNon-Critical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.14ColumnrafSpTrapVoltNread-writemandatoryNon-Critical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.15ColumnrafSpTrapPowerNread-writemandatoryNon-Critical Alert: Power.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.16ColumnrafSpTrapFanNread-writemandatoryNon-Critical Alert: Fan Error.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.17ColumnrafSpTrapCPUNread-writemandatoryNon-Critical Alert: Memory Error.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.18ColumnrafSpTrapMemoryNread-writemandatoryNon-Critical Alert: Memory Error.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.19ColumnrafSpTrapHardwareNread-writemandatoryNon-Critical Alert: Warning - refer to Message ID for specific condition.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.20ColumnrafSpTrapRLoginread-writemandatorySev-Off Alert: Event Remote Login.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.21ColumnrafSpTrapOsToSread-writemandatorySystem Alert: OS Timeout value exceeded.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.22ColumnrafSpTrapAppSread-writemandatorySystem Alert: Application Alert. Refer to Message ID for specific condition.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.23ColumnrafSpTrapPowerSread-writemandatorySystem Alert: Power On or Off.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.24ColumnrafSpTrapBootSread-writemandatorySystem Alert: System Boot Failure.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.25ColumnrafSpTrapLdrToSread-writemandatorySystem Alert: OS Loader Timeout.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.26ColumnrafSpTrapPFASread-writemandatorySystem Alert: Predictive Failure Analysis(PFA) information.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.27ColumnrafSpTrapSysLogSread-writemandatorySystem Alert: System Log 75% full.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.28ColumnrafSpTrapNwChangeSread-writemandatorySystem Alert: Network change notification.
1.3.6.1.4.1.2.3.51.3.3.1.3.2.1.29ColumnrafSpTrapAllAuditSread-writemandatorySystem Alert: All Audit Events notification.
1.3.6.1.4.1.2.3.51.3.3.1.3.30ScalargenerateTestAlertwrite-onlymandatoryGenerate a Test Alert. This will send a test alert to all configured and enabled remote alert receipients. The text portion of the alert will contain 'Applicat…
1.3.6.1.4.1.2.3.51.3.3.1.4NoderemoteAccessIds
1.3.6.1.4.1.2.3.51.3.3.1.4.1TableremoteAccessIdsTablenot-accessiblemandatoryTable of remote access profiles. This table lets you to configure all login profiles. You can define up to 12 unique profiles. Note: By default, the remote sup…
1.3.6.1.4.1.2.3.51.3.3.1.4.1.1RowremoteAccessIdsEntrynot-accessiblemandatoryRemote access entries.
1.3.6.1.4.1.2.3.51.3.3.1.4.1.1.1ColumnremoteAccessIdEntryIndexread-onlymandatoryIndex for Remote access entry.
1.3.6.1.4.1.2.3.51.3.3.1.4.1.1.2ColumnremoteAccessIdEntryUserIdread-writemandatoryRemote access entry null terminated string that contains the user-id. This can only be modified from blank to non-blank, then back to blank.
1.3.6.1.4.1.2.3.51.3.3.1.4.1.1.3ColumnremoteAccessIdEntryPasswordread-writemandatoryRemote access entry null terminated string that contains the password. On a read a NULL string will be returned for security reasons.
1.3.6.1.4.1.2.3.51.3.3.1.4.1.1.4ColumnremoteAccessIdEntryUserPwdLeftDaysread-onlymandatoryleft days before password expired for selected user
1.3.6.1.4.1.2.3.51.3.3.1.4.2TableremoteAccessUserAuthorityLevelTablenot-accessiblemandatoryTable of user authority level profiles.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1RowremoteAccessUserAuthorityLevelEntrynot-accessiblemandatoryUser authority level entries.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.1ColumnualIndexread-onlymandatoryIndex for User Authority Level entry.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.2ColumnualIdread-onlymandatoryUser ID
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.3ColumnualSupervisorread-writemandatoryUser has no restrictions.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.4ColumnualReadOnlyread-writemandatoryUser has only read-only access, and cannot perform any save, modify, clear, or state affecting operations (eg. restart IMM, restore defaults, upgrade the firmw…
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.5ColumnualAccountManagementread-writemandatoryUser can add/modify/delete users and change the global login settings in the Login Profiles panel.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.6ColumnualConsoleAccessread-writemandatoryUser can access the remote console.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.7ColumnualConsoleAndVirtualMediaAccessread-writemandatoryUser can access both the remote console and the virtual media feature.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.8ColumnualServerPowerAccessread-writemandatoryUser can access the power on and restart functions for the remote server. These functions are available via the Power/Restart panel.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.9ColumnualAllowClearLogread-writemandatoryUser can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.10ColumnualAdapterBasicConfigread-writemandatoryUser can modify configuration parameters in the System Settings and Alerts panels.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.11ColumnualAdapterNetworkAndSecurityConfigread-writemandatoryUser can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels.
1.3.6.1.4.1.2.3.51.3.3.1.4.2.1.12ColumnualAdapterAdvancedConfigread-writemandatoryUser has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the IMM, meaning that the user can also p…
1.3.6.1.4.1.2.3.51.3.3.1.5NodegroupProfiles
1.3.6.1.4.1.2.3.51.3.3.1.5.1TablegroupIdsTablenot-accessiblemandatoryTable of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles.
1.3.6.1.4.1.2.3.51.3.3.1.5.1.1RowgroupIdsEntrynot-accessiblemandatoryGroup ID entries.
1.3.6.1.4.1.2.3.51.3.3.1.5.1.1.1ColumngroupIndexread-onlymandatoryIndex for Group IDs entry.
1.3.6.1.4.1.2.3.51.3.3.1.5.1.1.2ColumngroupIdread-writemandatoryGroup ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones.
1.3.6.1.4.1.2.3.51.3.3.1.5.1.1.3ColumngroupRoleread-onlymandatoryGroup Role. It indicates if the group has supervisor, operator, or custom access.
1.3.6.1.4.1.2.3.51.3.3.1.5.2TablegroupRBSroleTablenot-accessiblemandatoryTable of Group Role profiles.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1RowgroupRBSroleEntrynot-accessiblemandatoryGroup Role entries.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.1ColumngroupRBSroleIndexread-onlymandatoryIndex for Group Role entry.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.2ColumngroupRBSroleIdread-onlymandatoryGroup ID
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.3ColumngroupRBSSupervisorread-writemandatoryGroup has no restrictions.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.4ColumngroupRBSOperatorread-writemandatoryGroup has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart IMM, restore defaults, upgrade the firmware…
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.5ColumngroupRBSNetworkSecurityread-writemandatoryGroup can modify the configuration in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.6ColumngroupRBSUserAccountManagementread-writemandatoryGroup can add/modify/delete users and change the Global Login Settings in the Login Profiles panel.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.7ColumngroupRBSRemoteConsoleAccessread-writemandatoryGroup can access the remote server console.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.8ColumngroupRBSRemoteConsoleRemoteDiskAccessread-writemandatoryGroup can access the remote server console and the remote disk functions for the remote server.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.9ColumngroupRBSServerPowerRestartAccessread-writemandatoryGroup can access the power on, restart and server timeout functions for the remote server.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.10ColumngroupRBSBasicAdapterConfigurationread-writemandatoryGroup can modify configuration parameters in the System Settings (excluding Contact, Location and Server Timeouts) and Alerts panels.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.11ColumngroupRBSClearEventLogread-writemandatoryGroup can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs.
1.3.6.1.4.1.2.3.51.3.3.1.5.2.1.12ColumngroupRBSAdvancedAdapterConfigurationread-writemandatoryGroup has no restrictions when configuring the adapter. In addition the user is said to have administrative access to the IMM, meaning that the user can also p…
1.3.6.1.4.1.2.3.51.3.3.1.6NodesshClientAuth
1.3.6.1.4.1.2.3.51.3.3.1.6.1TablesshClientAuthPubKeyTablenot-accessiblemandatoryA table that contains client authentication public key information.
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1RowsshClientAuthPubKeyEntrynot-accessiblemandatoryA information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessId…
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1.1ColumnsshClientAuthRemoteAccessIdIndexnot-accessiblemandatoryThe primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable.
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1.2ColumnsshClientAuthPubKeyIndexnot-accessiblemandatoryThe secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 t…
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1.3ColumnsshClientAuthPubKeyTyperead-onlymandatoryThe type of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1.4ColumnsshClientAuthPubKeySizeread-onlymandatoryThe size of the SSH public key represented by this entry.
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1.5ColumnsshClientAuthPubKeyFingerprintread-onlymandatoryThe RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the …
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1.6ColumnsshClientAuthPubKeyAcceptFromread-writemandatoryThis is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the AMM authenticated by the public key…
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1.7ColumnsshClientAuthPubKeyCommentread-writemandatoryThis is a descriptive string that the administrator may use to help identify the public key represented by this entry. It serves no function in the operation o…
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1.8ColumnsshClientAuthPubKeyActionread-writemandatoryimport(1) starts the TFTP file transfer of an SSH client authentication public key from the TFTP server to the AMM. The import operation is only accepted if th…
1.3.6.1.4.1.2.3.51.3.3.1.6.1.1.9ColumnsshClientAuthPubKeyEntryStatusread-writemandatoryThis object manages the creation and deletion of this entry. The steps recommended to install and to activate a new client authorization public key are: 1. Set…
1.3.6.1.4.1.2.3.51.3.3.1.6.2ScalarsshClientAuthPubKeyUnusedread-onlymandatoryThe number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key…
1.3.6.1.4.1.2.3.51.3.3.1.6.3ScalarsshClientAuthPubKeyTftpServerread-writemandatoryIP address or host name of the TFTP server where an SSH client authentication public key is to be installed from or exported to. The address must be entered in…
1.3.6.1.4.1.2.3.51.3.3.1.6.4ScalarsshClientAuthPubKeyFileNameread-writemandatoryFile name on the TFTP server of an SSH client authentication public key.
1.3.6.1.4.1.2.3.51.3.3.1.6.5ScalarsshClientAuthPubKeyFileFormatread-writemandatoryFile format of SSH client authentication public key files imported from or exported to the TFTP file server.
1.3.6.1.4.1.2.3.51.3.3.2NodespClock
1.3.6.1.4.1.2.3.51.3.3.2.1ScalarspClockDateAndTimeSettingread-writemandatoryIMM clock date and time setting. A date-time specification for the local time of day. For example to set the date and time to March 4, 2001 at 06:00:00AM, set …
1.3.6.1.4.1.2.3.51.3.3.2.2ScalarspClockTimezoneSettingread-writemandatoryIMM clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. The following table lists GMT offsets and associated DST information. DST is …
1.3.6.1.4.1.2.3.51.3.3.3NodespIdentification
1.3.6.1.4.1.2.3.51.3.3.3.1ScalarspTxtIdread-writemandatoryIMM text ID. Note: Do not put any 'space character' at end of the ID.
1.3.6.1.4.1.2.3.51.3.3.3.2ScalarspRoomIDread-writemandatoryRoom where the system is located. In some hardware configurations this object can only be read.
1.3.6.1.4.1.2.3.51.3.3.3.3ScalarspRackIDread-writemandatoryID for Rack that contains this system. In some hardware configurations this object can only be read.
1.3.6.1.4.1.2.3.51.3.3.3.4ScalarspRackUnitPositionread-writemandatoryPosition within the rack for this system. In some hardware configurations this object can only be read.
1.3.6.1.4.1.2.3.51.3.3.3.5ScalarspRackUnitHeightread-onlymandatoryNumber of rack units occupied by this system.
1.3.6.1.4.1.2.3.51.3.3.3.6ScalarspRackBladeBayread-onlymandatoryBay number for system contained in a blade chassis.
1.3.6.1.4.1.2.3.51.3.3.3.7ScalarspFullPostalAddressread-writemandatoryA NULL terminated 300 byte string that contains the full postal address for this system.
1.3.6.1.4.1.2.3.51.3.3.4NodenetworkConfiguration
1.3.6.1.4.1.2.3.51.3.3.4.1NodenetworkInterfaces
1.3.6.1.4.1.2.3.51.3.3.4.1.1NodeethernetInterface
1.3.6.1.4.1.2.3.51.3.3.4.1.1.1ScalarethernetInterfaceTyperead-onlymandatoryThe type of interface. Indicates 'Ethernet-1'.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.2ScalarethernetInterfaceEnabledread-writemandatoryDisable or enable the interface. Note: To alter any of the configuration settings for the ethernet interface the following procedure should be used: (1)This ob…
1.3.6.1.4.1.2.3.51.3.3.4.1.1.3ScalarethernetInterfaceHostNameread-writemandatoryContains the 64 byte null terminated DNS host name for this interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.4ScalarethernetInterfaceIPAddressread-writemandatoryContains the IP address for the ethernet interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.5ScalarethernetInterfaceAutoNegotiateread-writemandatoryIf this is enabled, then we should ignore Speed/Duplex.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.6ScalarethernetInterfaceDataRateread-writemandatorySpecifies the data transfer rate to be used over the ethernet interface 10Mb/100Mb/Auto. Note that the value of this variable is ignored if ethernetInterfaceAu…
1.3.6.1.4.1.2.3.51.3.3.4.1.1.7ScalarethernetInterfaceDuplexSettingread-writemandatorySpecifies the duplex settings for the data transfer rate to be used over the ethernet interface Half/Full/Auto.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.8ScalarethernetInterfaceLAAread-writemandatorySpecifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value mu…
1.3.6.1.4.1.2.3.51.3.3.4.1.1.9ScalarethernetInterfaceDhcpEnabledread-writemandatoryDisable or enable DHCP on this interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.10ScalarethernetInterfaceGatewayIPAddressread-writemandatoryContains the IP address of the gateway/router for the ethernet interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.11ScalarethernetInterfaceBIAread-onlymandatorySpecifies the burned-in MAC (BIA) address.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.12ScalarethernetInterfaceMTUread-writemandatoryContains the Maximum Transmission Unit(MTU) for the ethernet interface
1.3.6.1.4.1.2.3.51.3.3.4.1.1.13ScalarethernetInterfaceSubnetMaskread-writemandatoryContains the Subnet Mask for the ethernet interface
1.3.6.1.4.1.2.3.51.3.3.4.1.1.14NodedhcpEthernetInterface
1.3.6.1.4.1.2.3.51.3.3.4.1.1.14.1ScalardhcpHostNameread-onlymandatoryContains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.14.2ScalardhcpIPAddressread-onlymandatoryContains the IP address for the ehternet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.14.3ScalardhcpGatewayIPAddressread-onlymandatoryContains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.14.4ScalardhcpSubnetMaskread-onlymandatoryContains the Subnet Mask for the ethernet interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.14.5ScalardhcpDomainNameread-onlymandatoryContains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.14.6ScalardhcpPrimaryDNSServerread-onlymandatoryContains the Primary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.14.7ScalardhcpSecondaryDNSServerread-onlymandatoryContains the Secondary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.14.8ScalardhcpTertiaryDNSServerread-onlymandatoryContains the tertiary DNS server, assigned by the DHCP server.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.15ScalarethernetInterfaceVlanread-writemandatoryIf this is enabled, assign VLAN ID needs to be assigned. NOTE: This is not supported on blades.
1.3.6.1.4.1.2.3.51.3.3.4.1.1.16ScalarethernetInterfaceVlanIDread-writemandatoryContains the VLAN ID for the ethernet interface. NOTE: This is not supported in blades.
1.3.6.1.4.1.2.3.51.3.3.4.1.4NodeethernetInterfaceIPv6
1.3.6.1.4.1.2.3.51.3.3.4.1.4.2ScalarethernetInterfaceIPv6Enabledread-writemandatoryThe current IPv6 enabled or disabled state of this IMM. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this IM…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5NodeethernetInterfaceIPv6Config
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.1NodeethernetInterfaceIPv6LocalAddress
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.1.1ScalarethernetInterfaceIPv6LinkLocalAddressread-onlymandatoryThe IPv6 link local IP address for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.2NodeethernetInterfaceIPv6StaticIPConfig
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.2.1ScalarethernetInterfaceIPv6StaticIPConfigEnabledread-writemandatoryThe IPv6 static IP address enabled or disabled state for the ethernet interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.2.2ScalarethernetInterfaceIPv6StaticIPAddressread-writemandatoryThe IPv6 static IP address for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.2.3ScalarethernetInterfaceIPv6StaticIPAddressPrefixLenread-writemandatoryThe IPv6 static IP address prefix length for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value 0.
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.2.4ScalarethernetInterfaceIPv6StaticIPDefaultRouteread-writemandatoryThe IPv6 static IP address default route for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3NodeethernetInterfaceIPv6AutoIPConfig
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.2NodeethernetInterfaceDHCPv6Config
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.2.1ScalarethernetInterfaceDHCPv6Enabledread-writemandatoryThe DHCPv6 enabled or disabled state for the ethernet interface. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled is currently disabled, Disabling ethe…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.2.2ScalarethernetInterfaceDHCPv6IPAddressread-onlymandatoryThe IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or …
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.2.4ScalarethernetInterfaceDHCPv6DomainNameread-onlymandatoryThe 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is d…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.2.5ScalarethernetInterfaceDHCPv6PrimaryDNSServerread-onlymandatoryThe primary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server …
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.2.6ScalarethernetInterfaceDHCPv6SecondaryDNSServerread-onlymandatoryThe secondary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 serve…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.2.7ScalarethernetInterfaceDHCPv6TertiaryDNSServerread-onlymandatoryThe tertiary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.2.8ScalarethernetInterfaceDHCPv6Serverread-onlymandatoryThe DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHC…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.3NodeethernetInterfaceIPv6StatelessAutoConfig
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.3.1ScalarethernetInterfaceIPv6StatelessAutoConfigEnabledread-writemandatoryThe IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface. NOTE: If EthernetfInterfaceDHCPv6Enabled is currently disabled, Dis…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.3.2TableethernetInterfaceStatelessAutoConfigAddressesTablenot-accessiblemandatoryTable of stateless Auto-Config addresses entries
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.3.2.1RowethernetInterfaceStatelessAutoConfigAddressesEntrynot-accessiblemandatoryStateless Auto-Config address entries
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.3.2.1.1ColumnethernetInterfaceStatelessAutoConfigAddressesIndexread-onlymandatoryIndex for stateless Auto-Config addresses. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, this…
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.3.2.1.2ColumnethernetInterfaceStatelessAutoConfigAddressesread-onlymandatoryThe stateless Auto-Configuration IPv6 address. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, …
1.3.6.1.4.1.2.3.51.3.3.4.1.4.5.3.3.2.1.3ColumnethernetInterfaceStatelessAutoConfigAddressesPrefixLenread-onlymandatoryThe stateless Auto-Configration address prefix length. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently di…
1.3.6.1.4.1.2.3.51.3.3.4.1.5NodevlansSM
1.3.6.1.4.1.2.3.51.3.3.4.1.5.1NodevlansSMvlan1config
1.3.6.1.4.1.2.3.51.3.3.4.1.5.1.1ScalarvlansSMvlan1Nameread-writemandatoryThe name of VLAN1, 1-64 characters.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.1.2ScalarvlansSMvlan1vlanIdread-writemandatoryThe VLAN ID for VLAN1.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.1.3ScalarvlansSMvlan1Stateread-writemandatoryThe state of VLAN1
1.3.6.1.4.1.2.3.51.3.3.4.1.5.1.4ScalarvlansSMvlan1RemoteControlread-writemandatoryThe state of the Remote Control feature for VLAN1. Note that Remote Control can only be enabled on one VLAN.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.1.5ScalarvlansSMvlan1SSerialOverLanread-writemandatoryThe state of the Serail Over LAN feature for VLAN1. Note that Serial Over LAN can only be enabled on one VLAN.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2NodevlansSMvlan2config
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.1ScalarvlansSMvlan2Nameread-writemandatoryThe name of VLAN1, 1-64 characters.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.2ScalarvlansSMvlan2vlanIdread-writemandatoryThe VLAN ID for VLAN2.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.3ScalarvlansSMvlan2Stateread-writemandatoryThe state of VLAN2
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.4ScalarvlansSMvlan2RemoteControlread-writemandatoryThe state of the Remote Control feature for VLAN2. Note that Remote Control can only be enabled on one VLAN.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.5ScalarvlansSMvlan2SerialOverLanread-writemandatoryThe state of the Serail Over LAN feature for VLAN2. Note that Serial Over LAN can only be enabled on one VLAN.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.6NodevlansSMvlan2ipv4Config
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.6.1ScalarvlansSMvlan2IPv4Addressread-writemandatoryContains the IPv4 address for the VLAN2 interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.6.2ScalarvlansSMvlan2IPv4Gatewayread-writemandatoryContains the Gateway IPv4 address for the VLAN2 interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.6.3ScalarvlansSMvlan2IPv4SubnetMaskread-writemandatoryContains the Subnet Mask for the IPv4 address for the VLAN2 interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.7NodevlansSMvlan2ipv6Config
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.7.1ScalarvlansSMvlan2IPv6Addressread-writemandatoryContains the IPv6 address for the VLAN2 interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.7.2ScalarvlansSMvlan2IPv6Gatewayread-writemandatoryContains the Gateway IPv6 address for the VLAN2 interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.7.3ScalarvlansSMvlan2IPv6PrefixLengthread-writemandatoryContains the Prefix Length for the IPv6 address for the VLAN2 interface.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.8NodevlansSMvlan2ipv4StatusRoutes
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.8.1ScalarvlansSMvlan2IPv4StaticRouteIP1read-writemandatoryContains the IPv4 address for the first IPv4 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.8.2ScalarvlansSMvlan2IPv4StaticRouteSM1read-writemandatoryContains the Subnet Mask for the first IPv4 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.8.3ScalarvlansSMvlan2IPv4StaticRouteIP2read-writemandatoryContains the IPv4 address for the second IPv4 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.8.4ScalarvlansSMvlan2IPv4StaticRouteSM2read-writemandatoryContains the Subnet Mask for the second IPv4 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.8.5ScalarvlansSMvlan2IPv4StaticRouteIP3read-writemandatoryContains the IPv4 address for the third IPv4 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.8.6ScalarvlansSMvlan2IPv4StaticRouteSM3read-writemandatoryContains the Subnet Mask for the third IPv4 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.9NodevlansSMvlan2ipv6StatusRoutes
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.9.1ScalarvlansSMvlan2IPv6StaticRouteIP1read-writemandatoryContains the IPv6 address for the first IPv6 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.9.2ScalarvlansSMvlan2IPv6StaticRoutePL1read-writemandatoryContains the Prefix Length for the first IPv6 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.9.3ScalarvlansSMvlan2IPv6StaticRouteIP2read-writemandatoryContains the IPv6 address for the second IPv6 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.9.4ScalarvlansSMvlan2IPv6StaticRoutePL2read-writemandatoryContains the Prefix Length for the second IPv6 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.9.5ScalarvlansSMvlan2IPv6StaticRouteIP3read-writemandatoryContains the IPv6 address for the third IPv6 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.2.9.6ScalarvlansSMvlan2IPv6StaticRoutePL3read-writemandatoryContains the Prefix Length for the third IPv6 static route.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.3NodevlansSMvlanControl
1.3.6.1.4.1.2.3.51.3.3.4.1.5.3.1ScalarvlansSMvlanConfigRevertTimoutread-writemandatoryContains the VLAN Config Revert Timeout value.
1.3.6.1.4.1.2.3.51.3.3.4.1.5.3.2ScalarvlansSMvlanActionwrite-onlymandatoryWhen the 'apply' setting is written, the VLANs for System Management settings will be applied and take affect. The settings will not be saved until the 'commit…
1.3.6.1.4.1.2.3.51.3.3.4.1.10ScalarddnsStatusread-writemandatoryDynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configur…
1.3.6.1.4.1.2.3.51.3.3.4.1.11ScalarhostNameread-writemandatoryContains the DNS host name for this system. This object provides the exact same function as ethernetInterfaceHostName
1.3.6.1.4.1.2.3.51.3.3.4.1.12ScalarddnsDomainToUseread-writemandatoryThe domain name to be used with Dynamic DNS. The value shall be either dhcp or manual
1.3.6.1.4.1.2.3.51.3.3.4.1.13ScalardomainNameread-writemandatoryThe user assigned DNS domain name.
1.3.6.1.4.1.2.3.51.3.3.4.1.14NodelanOverUSBInterface
1.3.6.1.4.1.2.3.51.3.3.4.1.14.1ScalarimmUSBIPAddressread-writemandatoryContains the IP address for the LAN over USB of IMM.
1.3.6.1.4.1.2.3.51.3.3.4.1.14.2ScalarimmUSBSubnetMaskread-writemandatoryContains the Subnet Mask for the LAN over USB of IMM.
1.3.6.1.4.1.2.3.51.3.3.4.1.14.3ScalarosUSBIPAddressread-writemandatoryContains the IP address for the LAN over USB of OS.
1.3.6.1.4.1.2.3.51.3.3.4.2NodetcpProtocols
1.3.6.1.4.1.2.3.51.3.3.4.2.1NodesnmpAgentConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.1.1ScalarsnmpSystemNameread-writemandatoryA NULL terminated 48 byte string that contains the SNMP agent name.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.2ScalarsnmpSystemContactread-writemandatoryA NULL terminated 48 byte string that contains the SNMP agent contact name.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.3ScalarsnmpSystemLocationread-writemandatoryA NULL terminated 48 byte string that contains the SNMP agent location name.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.4ScalarsnmpSystemAgentTrapsDisableread-writemandatoryDisable or enable SNMP traps.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.5NodesnmpAgentCommunityConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.1.5.1TablesnmpCommunityTablenot-accessiblemandatoryTable of SNMP Community entries
1.3.6.1.4.1.2.3.51.3.3.4.2.1.5.1.1RowsnmpCommunityEntrynot-accessiblemandatoryCommunity table entries
1.3.6.1.4.1.2.3.51.3.3.4.2.1.5.1.1.1ColumnsnmpCommunityEntryIndexread-onlymandatoryIndex for SNMP Agent Community entry.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.5.1.1.2ColumnsnmpCommunityEntryCommunityNameread-writemandatorySNMP Community entry name. Note: Set snmpSystemAgentEnable to disabled before performing a set of this object.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.5.1.1.3ColumnsnmpCommunityEntryCommunityIpAddress1read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string(eg. 9.37.44.2) or host name. This field also allows two wildcard values for re…
1.3.6.1.4.1.2.3.51.3.3.4.2.1.5.1.1.4ColumnsnmpCommunityEntryCommunityIpAddress2read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string(eg. 9.37.44.2) or a host name. This field also allows two wildcard values for …
1.3.6.1.4.1.2.3.51.3.3.4.2.1.5.1.1.5ColumnsnmpCommunityEntryCommunityIpAddress3read-writemandatorySNMP Community IP address or host name. Can either be a dotted decimal IP string(eg. 9.37.44.2) or a host name. This field also allows two wildcard values for …
1.3.6.1.4.1.2.3.51.3.3.4.2.1.5.1.1.6ColumnsnmpCommunityEntryCommunityViewTyperead-writemandatoryAccess Level of the SNMPv1 managers. Note this parameter is set for each community. Therefore all three managers in the same community have the same access lev…
1.3.6.1.4.1.2.3.51.3.3.4.2.1.6Scalarsnmpv1SystemAgentEnableread-writemandatoryDisable or enable the SNMPv1 agent. Note: When this object has a value of enabled the fields listed below are checked. If this verification fails an error resp…
1.3.6.1.4.1.2.3.51.3.3.4.2.1.7Scalarsnmpv3SystemAgentEnableread-writemandatoryDisable or enable the SNMPv3 agent. Note: To alter any of the configuration settings for the SNMP Agent the following procedure should be used: (1)This object …
1.3.6.1.4.1.2.3.51.3.3.4.2.1.8NodesnmpAgentUserProfileConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.1.8.1TablesnmpUserProfileTablenot-accessiblemandatoryTable of SNMPv3 User Profile entries
1.3.6.1.4.1.2.3.51.3.3.4.2.1.8.1.1RowsnmpUserProfileEntrynot-accessiblemandatorySNMP User Profile entries
1.3.6.1.4.1.2.3.51.3.3.4.2.1.8.1.1.1ColumnsnmpUserProfileEntryIndexread-onlymandatoryIndex for SNMPv3 Agent User Profile entry.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.8.1.1.2ColumnsnmpUserProfileEntryAuthProtread-writemandatorySNMPv3 User Profile entry - Authentication Protocol supported by the user.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.8.1.1.3ColumnsnmpUserProfileEntryPrivProtread-writemandatorySNMPv3 User Profile entry - Privacy Protocol supported by the user. The Privacy Password must be set and the Authentication Protocol must be md5 or sha before …
1.3.6.1.4.1.2.3.51.3.3.4.2.1.8.1.1.4ColumnsnmpUserProfileEntryPrivPasswordread-writemandatorySNMPv3 User Profile entry - Privacy password for the user. NOTE: Value returned for the GET command is meaningless for this MIB object for security reason.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.8.1.1.5ColumnsnmpUserProfileEntryViewTyperead-writemandatorySNMPv3 User Profile entry - Access level (Get and Set) of the user.
1.3.6.1.4.1.2.3.51.3.3.4.2.1.8.1.1.6ColumnsnmpUserProfileEntryIpAddressread-writemandatorySNMPv3 User Profile entry - IP address or host name. Can either be a dotted decimal IP string (e.g. 9.37.44.2) or if DNS is enabled a host name.
1.3.6.1.4.1.2.3.51.3.3.4.2.2NodednsConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.2.1ScalardnsEnabledread-writemandatoryDisable or enable the DNS agent. Note that when this object has a value of enabled that the following is verifed, if this verification fails a error response w…
1.3.6.1.4.1.2.3.51.3.3.4.2.2.2ScalardnsServerIPAddress1read-writemandatoryContains the primary DNS server IP address.
1.3.6.1.4.1.2.3.51.3.3.4.2.2.3ScalardnsServerIPAddress2read-writemandatoryContains the secondary DNS server IP address.
1.3.6.1.4.1.2.3.51.3.3.4.2.2.4ScalardnsServerIPAddress3read-writemandatoryContains the tertiary DNS server IP address.
1.3.6.1.4.1.2.3.51.3.3.4.2.2.12ScalardnsServerIPv6Address1read-writemandatoryContains the primary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.3.3.4.2.2.13ScalardnsServerIPv6Address2read-writemandatoryContains the secondary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.3.3.4.2.2.14ScalardnsServerIPv6Address3read-writemandatoryContains the tertiary IPv6 DNS server address.
1.3.6.1.4.1.2.3.51.3.3.4.2.2.20ScalardnsPriorityread-writemandatoryTells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server.
1.3.6.1.4.1.2.3.51.3.3.4.2.3NodesmtpConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.3.1ScalarsmtpServerNameOrIPAddressread-writemandatoryA NULL terminated 64 byte string that contains the SMTP server Host name or IP address(a.b.c.d).
1.3.6.1.4.1.2.3.51.3.3.4.2.3.2ScalarsmtpServerPortread-writemandatorySMTP server port number.
1.3.6.1.4.1.2.3.51.3.3.4.2.3.3ScalarsmtpServerAuthenticationread-writemandatoryEnable/disable SMTP-AUTH function. smtpServerAuthenticationUser and smtpServerAuthenticationPassword must be SET before smtpServerAuthentication is enabled or …
1.3.6.1.4.1.2.3.51.3.3.4.2.3.4ScalarsmtpServerAuthenticationUserread-writemandatorySMTP authentication user name
1.3.6.1.4.1.2.3.51.3.3.4.2.3.5ScalarsmtpServerAuthenticationPasswordread-writemandatorySMTP authentication password. On a read a NULL string will be returned for security reasons.
1.3.6.1.4.1.2.3.51.3.3.4.2.3.6ScalarsmtpServerAuthenticationMethodread-writemandatorySMTP authentication method , support CRAM-MD5 and PLAIN only
1.3.6.1.4.1.2.3.51.3.3.4.2.3.7ScalarsmtpServerReversePathread-writemandatoryA NULL terminated 256 byte string that contains the SMTP Reverse Path. The user can substitute their own sender information in place of the IMM2 default sender…
1.3.6.1.4.1.2.3.51.3.3.4.2.4NodetcpApplicationConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.4.1ScalartelnetConnectionCountsread-writemandatoryThe number of telnet connections that can be active concurrently.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.2ScalarslpAddrTyperead-writemandatorySet SLP address type to 0 (multicast) or 1 (broadcast). Note that when slpAddrType is set to broadast value then the multicast address set in in slpMulticastAd…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.3ScalarslpMulticastAddrread-onlymandatoryService Locator Protocol Multicast address
1.3.6.1.4.1.2.3.51.3.3.4.2.4.5NodesshServerConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.4.5.1ScalarsshServerHostKeySizeread-onlymandatoryThe size of the public/private host key pair. NOTE: The IMM supports only the bits1048 value.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.5.2ScalarsshServerHostKeyFingerprintread-onlymandatoryThe RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure S…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.5.3ScalarsshServerHostKeyGenerateread-writemandatoryInitiate the new Host Keys generation process for the IMM SSH Server. NOTE: Value returned for the GET command is meaningless for this MIB object.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.5.4ScalarsshServerHostKeyGenerateProgressread-onlymandatoryIndicate the progress of the key generation process.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.5.5ScalarsshEnableread-writemandatoryDisable/Enable SSH.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6NodesslConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.1NodesslHTTPSServerConfigForWeb
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.1.1ScalarsslEnableHTTPSforWebread-writemandatoryDisable/Enable HTTPS support for web. Use this field to enable or disable SSL for the web interface. The IMM must be restarted before the selected value (enabl…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.1.2ScalarsslHTTPSServerWebCertificateGenerationread-writemandatoryInitiate the new key and certificate generation process for the web HTTPS. The required fields in sslCertificateData must be set to valid contents. generateNew…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.1.3ScalarsslHTTPSServerWebCertificateTransferread-writemandatorysslConfigTftpServer and sslConfigFileName must contain valid values. importSignedCertificate - Use this to import a signed certificate. To obtain a signed cert…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.1.4ScalarsslHTTPSWebCertificateStatusread-onlymandatoryGet the status of the installed Web certificates. 1 = Private Key and Cert/CSR not available. 2 = Private Key and Self-signed cert installed. 3 = Private Key a…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.1.5ScalarsslHTTPSWebCertificateExpirationDateread-onlymandatoryExpiration date of the HTTPS Web Server certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.1.6ScalarsslHTTPSWebCertificateRemovewrite-onlymandatoryremoveServerCertificate - Remove HTTPS Web Server certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.2NodesslHTTPSServerConfigForCIMXML
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.2.1ScalarsslEnableHTTPSforCIMXMLread-writemandatoryDisable/Enable HTTPS support for web. Use this field to enable or disable SSL for the web interface. The IMM must be restarted before the selected value (enabl…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.2.2ScalarsslHTTPSServerCIMXMLCertificateGenerationread-writemandatoryInitiate the new key and certificate generation process for CIMXML communication. The required fields in sslCertificateData must be set to valid contents. gene…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.2.3ScalarsslHTTPSServerCIMXMLCertificateTransferread-writemandatorysslConfigTftpServer and sslConfigFileName must contain valid values. importSignedCertificate - Use this to import a signed certificate. To obtain a signed cert…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.2.4ScalarsslHTTPSCIMXMLCertificateStatusread-onlymandatoryGet the status of the installed CIM/XML certificates. 1 = Private Key and Cert/CSR not available. 2 = Private Key and Self-signed cert installed. 3 = Private K…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.2.5ScalarsslHTTPSCIMXMLCertificateExpirationDateread-onlymandatoryExpiration date of the HTTPS CIM/XML Server certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.2.6ScalarsslHTTPSCIMXMLCertificateRemovewrite-onlymandatoryremoveServerCertificate - Remove HTTPS CIM/XML Server certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3NodesslClientConfigForLDAP
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.1ScalarsslEnableClientLDAPread-writemandatoryUse this field to enable or disable SSL for the LDAP Client. The value selected takes effect immediately. Note that in order to enable SSL, a valid SSL certifi…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.2ScalarsslClientLDAPCertificateGenerationread-writemandatoryInitiate the new key and certificate generation process for the LDAP Client Certificates. The required fields in sslCertificateData must be set to valid conten…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.3ScalarsslClientLDAPCertificateDownloadread-writemandatorysslConfigTftpServer and sslConfigFileName must contain valid values. downloadCertificate - Use this link to download a copy of the currently installed c ertifi…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.4ScalarsslClientLDAPCertificateImportread-writemandatorysslConfigTftpServer and sslConfigFileName must contain valid values. importSignedCertificate - Use this to import a signed certificate. To obtain a signed cert…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.5ScalarsslClientLDAPCertificateStatusread-onlymandatoryGet the status of the installed SSL Client certificates. 1 = Private Key and Cert/CSR not available. 2 = Private Key and Self-signed cert installed. 3 = Privat…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.6ScalarsslClientLDAPCertificateExpirationDateread-onlymandatoryExpiration date of the LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.7ScalarsslClientLDAPCertificateRemovewrite-onlymandatoryremoveServerCertificate - Remove LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.8ScalarsslClientLDAPTrustedCertificate1Statusread-onlymandatoryGet the status of the installed SSL Client trusted certificates. 0 = certificate not installed 1 = certificate installed.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.9ScalarsslClientLDAPTrustedCertificate1ExpirationDateread-onlymandatoryExpiration date of the LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.10ScalarsslClientLDAPTrustedCertificate1Removewrite-onlymandatoryremoveServerCertificate - Remove LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.11ScalarsslClientLDAPTrustedCertificate2Statusread-onlymandatoryGet the status of the installed SSL Client trusted certificates. 0 = certificate not installed 1 = certificate installed.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.12ScalarsslClientLDAPTrustedCertificate2ExpirationDateread-onlymandatoryExpiration date of the LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.13ScalarsslClientLDAPTrustedCertificate2Removewrite-onlymandatoryremoveServerCertificate - Remove LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.14ScalarsslClientLDAPTrustedCertificate3Statusread-onlymandatoryGet the status of the installed SSL Client trusted certificates. 0 = certificate not installed 1 = certificate installed.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.15ScalarsslClientLDAPTrustedCertificate3ExpirationDateread-onlymandatoryExpiration date of the LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.16ScalarsslClientLDAPTrustedCertificate3Removewrite-onlymandatoryremoveServerCertificate - Remove LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.17ScalarsslClientLDAPTrustedCertificate4Statusread-onlymandatoryGet the status of the installed SSL Client trusted certificates. 0 = certificate not installed 1 = certificate installed.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.18ScalarsslClientLDAPTrustedCertificate4ExpirationDateread-onlymandatoryExpiration date of the LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.3.19ScalarsslClientLDAPTrustedCertificate4Removewrite-onlymandatoryremoveServerCertificate - Remove LDAP Client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.4ScalarsslConfigTftpServerread-writemandatoryTo download or import certificates, set the IP address or host name of the TFTP server where the file should be transferred to or from. The address must be ent…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.5ScalarsslConfigFileNameread-writemandatoryFile name on target system for the downloaded or imported certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6NodesslCertificateData
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.1ScalarsslCertificateDataCountryread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the country where the IMM physically resides. This field must contai…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.2ScalarsslCertificateDataStateorProvinceread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the state or province where the IMM physically resides. This field m…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.3ScalarsslCertificateDataCityOrLocalityread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the city or locality where the IMM physically resides. This field ma…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.4ScalarsslCertificateDataOrganizationNameread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the company or organization that owns the IMM. When this is used to …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.5ScalarsslCertificateDataIMMHostNameread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the IMM host name that currently appears in the browser URL address …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.6ScalarsslCertificateDataContactread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field to indicate the name of a contact person responsible for the IMM. This field may…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.7ScalarsslCertificateDataEmailAddrread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field to indicate the email address of a contact person responsible for the IMM. This …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.8ScalarsslCertificateDataOrganizationUnitread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field to indicate the unit within the company or organization that owns the IMM. This …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.9ScalarsslCertificateDataSurnameread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field for additional information, such as the surname of a person responsible for the …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.10ScalarsslCertificateDataGivenNameread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field for additional information, such as the given name of a person responsible for t…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.11ScalarsslCertificateDataInitialsread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field for additional information, such as the initials of a person responsible for the…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.12ScalarsslCertificateDataDNQualifierread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field for additional information, such as a Distinguished Name Qualifier for the IMM. …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.13ScalarsslCertificateDataCSRChallengePasswordread-writemandatoryOptional field for generating a CSR. Use this field to assign a password to the CSR. This field may contain a maximum of 30 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.14ScalarsslCertificateDataCSRUnstructuredNameread-writemandatoryOptional field for generating a CSR. Use this field for additional information, such as an unstructured name assigned to the IMM. This field may contain a maxi…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.15ScalarsslCertificateDataSubjectAltName1read-writemandatoryOptional field to allow an SSL certificate to specify an additional name that the certificate should match. This field may contain a maximum of 60 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.16ScalarsslCertificateDataSubjectAltName2read-writemandatoryOptional field to allow an SSL certificate to specify an additional name that the certificate should match. This field may contain a maximum of 60 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.17ScalarsslCertificateDataSubjectAltName3read-writemandatoryOptional field to allow an SSL certificate to specify an additional name that the certificate should match. This field may contain a maximum of 60 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.18ScalarsslCertificateDataSubjectAltName4read-writemandatoryOptional field to allow an SSL certificate to specify an additional name that the certificate should match. This field may contain a maximum of 60 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.19ScalarsslCertificateDataSubjectAltName5read-writemandatoryOptional field to allow an SSL certificate to specify an additional name that the certificate should match. This field may contain a maximum of 60 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.20ScalarsslCertificateDataSubjectAltName6read-writemandatoryOptional field to allow an SSL certificate to specify an additional name that the certificate should match. This field may contain a maximum of 60 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.21ScalarsslCertificateDataSubjectAltName7read-writemandatoryOptional field to allow an SSL certificate to specify an additional name that the certificate should match. This field may contain a maximum of 60 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.6.22ScalarsslCertificateDataSubjectAltName8read-writemandatoryOptional field to allow an SSL certificate to specify an additional name that the certificate should match. This field may contain a maximum of 60 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.6.7ScalarsslCertificateCSRDownloadFormatread-writemandatoryYou can download the generated CSR in DER format or PEM format. If the CA asks you to copy the contents of the CSR file into a web browser window, PEM format i…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.7NodecryptoSettings
1.3.6.1.4.1.2.3.51.3.3.4.2.4.7.1ScalarcryptoModeread-writemandatoryBasic or NIST mode enabled. The Basic mode is compatible with older firmware versions and with browers and other network clients that do not implement the stri…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.7.2ScalarcryptoSnmpv3read-writemandatoryDisallow or allow SNMPv3 accounts that do not comply with NIST compliance mode when NIST compliance has been enabled.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.7.3NodecryptoInsufCompliance
1.3.6.1.4.1.2.3.51.3.3.4.2.4.7.3.1TablecryptoInsufComplianceTablenot-accessiblemandatoryThis table contains items not in compliance with the current cyrptoMode setting.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.7.3.1.1RowcryptoInsufComplianceEntrynot-accessiblemandatoryEach row contains an insufficient compliance item name.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.7.3.1.1.1ColumncryptoInsufComplianceItemIndexread-onlymandatoryThe index number of one insufficient compliance item entry.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.7.3.1.1.2ColumncryptoInsufComplianceItemNameread-onlymandatoryThe name of one insufficient compliance item.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.8NodecertDomainNames
1.3.6.1.4.1.2.3.51.3.3.4.2.4.8.1TablecertDomainNameTablenot-accessiblemandatoryThis table contains certificate domain names and status.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.8.1.1RowcertDomainNameEntrynot-accessiblemandatoryEach row contains a certificate domain name and status.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.8.1.1.1ColumncertDomainNameIndexread-onlymandatoryThe index number of one certificate domain name entry.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.8.1.1.2ColumncertDomainNameread-onlymandatoryThe Certificate Domain Name of one certificate domain name entry.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.8.1.1.3ColumncertDomainNameStatusread-onlymandatoryThe status of the Certificate Domain Name entry.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.8.2ScalaraddCertDomainNameread-writemandatoryAdd one Certificate Domain Name to the certificate domain name table.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.8.3ScalarrmCertDomainNameread-writemandatoryRemove one Certificate Domain Name to the certificate domain name table.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9NodeskrServers
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.1TableskrServerTablenot-accessiblemandatoryThis table contains Storage Key Repository Server hostnames and ports.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.1.1RowskrServerEntrynot-accessiblemandatoryEach row contains a Storage Key Repository Server hostname and port.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.1.1.1ColumnskrServerIndexread-onlymandatoryThe index number of one Storage Key Repository Server entry.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.1.1.2ColumnskrServerHostnameread-writemandatoryStorage Key Repository Server hostname or IP address.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.1.1.3ColumnskrServerPortread-writemandatoryStorage Key Repository Server port number.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.2ScalarskrServerCertActionwrite-onlymandatoryimportServerCertificate - Import Storage Key Repository Server certificate. For tftp mode, skrConfigFtpServer and skrConfigFileName must contain valid values. …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.3ScalarskrDeviceGroupread-writemandatoryAn optional NULL terminated 16 character string that contains the Device Group that the server drives belong to.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.4NodeskrClientConfigCertficate
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.4.1ScalarskrClientCertificateGenerationread-writemandatoryInitiate the new key and certificate generation process for the key repository client. The required fields in skrCertificateData must be set to valid contents.…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.4.2ScalarskrClientCertificateTransferread-writemandatoryFor tftp mode, skrConfigFtpServer and skrConfigFileName must contain valid values. For sftp mode, skrConfigFTPCallUserID and skrConfigFtpCallPassword must also…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.4.3ScalarskrClientCertificateStatusread-onlymandatoryGet the status of the installed Web certificates. 1 = Private Key and Cert/CSR not available. 2 = Private Key and Self-signed cert installed. 3 = Private Key a…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.4.4ScalarskrClientCertificateExpirationDateread-onlymandatoryExpiration date of the SKR client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.4.5ScalarskrClientCertificateRemovewrite-onlymandatoryremoveServerCertificate - Remove SKR client certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5NodeskrCertificateData
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.1ScalarskrCertificateDataCountryread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the country where the IMM physically resides. This field must contai…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.2ScalarskrCertificateDataStateorProvinceread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the state or province where the IMM physically resides. This field m…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.3ScalarskrCertificateDataCityOrLocalityread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the city or locality where the IMM physically resides. This field ma…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.4ScalarskrCertificateDataOrganizationNameread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the company or organization that owns the IMM. When this is used to …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.5ScalarskrCertificateDataIMMHostNameread-writemandatoryRequired field for generating a CSR or self-signed certificate. Use this field to indicate the IMM host name that currently appears in the browser URL address …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.6ScalarskrCertificateDataContactread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field to indicate the name of a contact person responsible for the IMM. This field may…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.7ScalarskrCertificateDataEmailAddrread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field to indicate the email address of a contact person responsible for the IMM. This …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.8ScalarskrCertificateDataOrganizationUnitread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field to indicate the unit within the company or organization that owns the IMM. This …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.9ScalarskrCertificateDataSurnameread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field for additional information, such as the surname of a person responsible for the …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.10ScalarskrCertificateDataGivenNameread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field for additional information, such as the given name of a person responsible for t…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.11ScalarskrCertificateDataInitialsread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field for additional information, such as the initials of a person responsible for the…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.12ScalarskrCertificateDataDNQualifierread-writemandatoryOptional field for generating a CSR or self-signed certificate. Use this field for additional information, such as a Distinguished Name Qualifier for the IMM. …
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.13ScalarskrCertificateDataCSRChallengePasswordread-writemandatoryOptional field for generating a CSR. Use this field to assign a password to the CSR. This field may contain a maximum of 30 characters.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.5.14ScalarskrCertificateDataCSRUnstructuredNameread-writemandatoryOptional field for generating a CSR. Use this field for additional information, such as an unstructured name assigned to the IMM. This field may contain a maxi…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.6ScalarskrConfigFtpServerread-writemandatoryTo import certificates, set the IP address or host name of the server where the file should be transferred from. The address must be entered in a dotted decima…
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.7ScalarskrConfigFtpServerModeread-writemandatoryThis field specifies the FTP mode used.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.8ScalarskrConfigFtpCallPortread-writemandatoryThis field specifies the port on remote TFTP/SFTP server for data transmission (default values are 69/22, respectively).
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.9ScalarskrConfigFTPCallUserIDread-writemandatoryThis field specifies the user account to login remote SFTP server.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.10ScalarskrConfigFtpCallPasswordread-writemandatoryThis field specifies the password to login remote SFTP server.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.11ScalarskrConfigFileNameread-writemandatoryFile name on target system for the imported certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.4.9.12ScalarskrServerCertificateExpirationDateread-onlymandatoryExpiration date of the SKR Server certificate.
1.3.6.1.4.1.2.3.51.3.3.4.2.5NodetcpPortAssignmentCfg
1.3.6.1.4.1.2.3.51.3.3.4.2.5.1ScalartcpPortsRestoreDefaultwrite-onlymandatoryReset all the ports to the factory defaults.
1.3.6.1.4.1.2.3.51.3.3.4.2.5.2ScalarhttpPortAssignmentread-writemandatoryHTTP port number. Default value is 80. Once changed, the url's have to include :port at the end.
1.3.6.1.4.1.2.3.51.3.3.4.2.5.3ScalarhttpsPortAssignmentread-writemandatorySSL port number. Default value is 443. Once changed, the url's have to include :port at the end.
1.3.6.1.4.1.2.3.51.3.3.4.2.5.4ScalartelnetLegacyCLIPortAssignmentread-writemandatorytelnet port number. Default value is 23.
1.3.6.1.4.1.2.3.51.3.3.4.2.5.6ScalarsshLegacyCLIPortAssignmentread-writemandatorySSH port number. Default value is 22.
1.3.6.1.4.1.2.3.51.3.3.4.2.5.8ScalarsnmpAgentPortAssignmentread-writemandatorySNMP Agent port number. Default value is 161.
1.3.6.1.4.1.2.3.51.3.3.4.2.5.9ScalarsnmpTrapsPortAssignmentread-writemandatorySNMP Traps port number. Default value is 162.
1.3.6.1.4.1.2.3.51.3.3.4.2.5.10ScalarremvidPortAssignmentread-writemandatoryRemote Console port number. Default value is 3900.
1.3.6.1.4.1.2.3.51.3.3.4.2.5.11ScalaribmSystemDirectorHttpPortAssignmentread-writemandatoryIBM Systems Director Http port number.
1.3.6.1.4.1.2.3.51.3.3.4.2.5.12ScalaribmSystemDirectorHttpsPortAssignmentread-writemandatoryIBM Systems Director Https port number.
1.3.6.1.4.1.2.3.51.3.3.4.2.6NodeldapClientCfg
1.3.6.1.4.1.2.3.51.3.3.4.2.6.1ScalarldapServer1NameOrIPAddressread-writemandatoryA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.3.3.4.2.6.2ScalarldapServer1PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.3.3.4.2.6.3ScalarldapServer2NameOrIPAddressread-writemandatoryA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.3.3.4.2.6.4ScalarldapServer2PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.3.3.4.2.6.5ScalarldapServer3NameOrIPAddressread-writemandatoryA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.3.3.4.2.6.6ScalarldapServer3PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.3.3.4.2.6.7ScalarldapServer4NameOrIPAddressread-writemandatoryA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).
1.3.6.1.4.1.2.3.51.3.3.4.2.6.8ScalarldapServer4PortNumberread-writemandatoryLDAP server port number.
1.3.6.1.4.1.2.3.51.3.3.4.2.6.9ScalarldapRootDNread-writemandatoryDistinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com.
1.3.6.1.4.1.2.3.51.3.3.4.2.6.10ScalarldapUserSearchBaseDNread-writedeprecatedAs part of the user authentication process, it is necessary to search the LDAP server for one or more attributes associated with a particular user. Any search …
1.3.6.1.4.1.2.3.51.3.3.4.2.6.11ScalarldapGroupFilterread-writemandatoryThis filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Other…
1.3.6.1.4.1.2.3.51.3.3.4.2.6.12ScalarldapBindingMethodread-writemandatoryOn initial binds to the LDAP server during user authentication, there are three options: Anonymous authentication: Bind attempt is made without a client DN or …
1.3.6.1.4.1.2.3.51.3.3.4.2.6.13ScalarldapClientAuthenticationDNread-writemandatoryThe initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client …
1.3.6.1.4.1.2.3.51.3.3.4.2.6.14ScalarldapClientAuthenticationPasswordread-writemandatoryThe client authentication password
1.3.6.1.4.1.2.3.51.3.3.4.2.6.15ScalarldapRoleBasedSecurityEnabledread-writemandatoryA value of true for RoleBasedSecurityEnabled indicates enhanced will be used by the service processor. A value of false for RoleBasedSecurityEnabled indicates …
1.3.6.1.4.1.2.3.51.3.3.4.2.6.16ScalarldapServerTargetNameread-writemandatoryWhen administrator chooses Enhanced Role Based Security authentication model, he can associate one IMM with one managed target object in Snap-in (one tool to c…
1.3.6.1.4.1.2.3.51.3.3.4.2.6.17ScalarldapUIDsearchAttributeread-writemandatoryWhen the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aime…
1.3.6.1.4.1.2.3.51.3.3.4.2.6.18ScalarldapGroupSearchAttributeread-writemandatoryWhen the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is req…
1.3.6.1.4.1.2.3.51.3.3.4.2.6.19ScalarldapLoginPermissionAttributeread-writemandatoryWhen a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissio…
1.3.6.1.4.1.2.3.51.3.3.4.2.6.20ScalarldapUseDNSOrPreConfiguredServersread-writemandatoryThe MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used…
1.3.6.1.4.1.2.3.51.3.3.4.2.6.21ScalarldapDomainSourceread-writemandatoryThe DNS SRV request sent to the DNS server must specify a domain name. The LDAP client will determine where to get this domain name based on one of the followi…
1.3.6.1.4.1.2.3.51.3.3.4.2.6.22ScalarldapForestNameread-writemandatoryIn order to discover Global Catalogs (GC), the forest name must be configured in the ForestName property. The Global Catalogs are required for users who belong…
1.3.6.1.4.1.2.3.51.3.3.4.2.6.23ScalarldapAuthCfgread-writemandatoryIf ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LD…
1.3.6.1.4.1.2.3.51.3.3.4.2.6.24ScalarldapSearchDomainread-writemandatoryThis parameter may be used as the domain name in the DNS SRV request, depending on how the Domain Source parameter is configured.
1.3.6.1.4.1.2.3.51.3.3.4.2.6.25ScalarldapServiceNameread-writemandatoryThe DNS SRV request sent to the DNS server must also specify a service name. The configured value will be used for this purpose. If left blank, the default val…
1.3.6.1.4.1.2.3.51.3.3.4.2.8NodentpConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.8.1ScalarntpEnableread-writemandatoryDisable/Enable the NTP client. The client will update the IMM system clock at the frequency specified.
1.3.6.1.4.1.2.3.51.3.3.4.2.8.2ScalarntpIpAddressHostname1read-writemandatoryFirst NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.2.3.51.3.3.4.2.8.3ScalarntpUpdateFrequencyread-writemandatoryThe frequency in minutes that the NTP service runs. The value range is 3 to 1440.
1.3.6.1.4.1.2.3.51.3.3.4.2.8.4ScalarntpIpAddressHostname2read-writemandatorySecond NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.2.3.51.3.3.4.2.8.5ScalarntpUpdateClockwrite-onlymandatoryUpdate the IMM system clock with the specified NTP server. A valid NTP server must be configured first.
1.3.6.1.4.1.2.3.51.3.3.4.2.8.6ScalarntpIpAddressHostname3read-writemandatoryThird NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.2.3.51.3.3.4.2.8.7ScalarntpIpAddressHostname4read-writemandatoryFourth NTP server's IP address or hostname if DNS is enabled and configured.
1.3.6.1.4.1.2.3.51.3.3.4.2.10NodeipmiConfig
1.3.6.1.4.1.2.3.51.3.3.4.2.10.1ScalaripmiEnableread-writemandatoryDisable/Enable IPMI
1.3.6.1.4.1.2.3.51.3.3.5NodeconfigurationManagement
1.3.6.1.4.1.2.3.51.3.3.5.1ScalarconfigurationManagementTftpServerread-writemandatoryTo save or restore the system configuration, set the IP address or host name of the TFTP server where the file should be transferred to or from. The address mu…
1.3.6.1.4.1.2.3.51.3.3.5.2ScalarconfigurationManagementFileNameread-writemandatoryFile name of the saved file or restore-from file.
1.3.6.1.4.1.2.3.51.3.3.5.3ScalarconfigurationManagementSaveStartread-writemandatoryStart saving the configuration file to the specified target file and system. Using execute will cause the SNMP client to wait for the save operation to complet…
1.3.6.1.4.1.2.3.51.3.3.5.4ScalarconfigurationManagementRestoreStartread-writemandatoryStart restoring the configuration file from the specified target file and system. Using execute will cause the SNMP client to wait for the restore operation to…
1.3.6.1.4.1.2.3.51.3.3.5.5ScalarconfigurationManagementStatusread-onlymandatoryGet the status of the last configurationManagement operation which was initiated through SNMP method.
1.3.6.1.4.1.2.3.51.3.3.7ScalarimmVersionCheckread-onlymandatoryGet the IMM version type.
1.3.6.1.4.1.2.3.51.3.4NodegeneralSystemSettings
1.3.6.1.4.1.2.3.51.3.4.1NodeserverTimers
1.3.6.1.4.1.2.3.51.3.4.1.1ScalaroSHangread-writemandatoryNumber, in 1 second intervals, the IMM will check to insure the OS is operating properly. If the operating system fails to respond within 6 seconds to one of t…
1.3.6.1.4.1.2.3.51.3.4.1.2ScalaroSLoaderread-writemandatoryNumber in 30 second intervals the remote IMM will wait between completion of POST and the end of loading the OS. If this interval is exceeded, the IMM will gen…
1.3.6.1.4.1.2.3.51.3.4.2ScalarnetworkPXEbootread-writemandatoryModify the system's boot sequence for the next system restart in order to attempt a PXE/DHCP network boot. The system's boot sequence(set via the BIOS settings…
1.3.6.1.4.1.2.3.51.3.5NodesystemPower
1.3.6.1.4.1.2.3.51.3.5.1NodepowerStatistics
1.3.6.1.4.1.2.3.51.3.5.1.1ScalarcurrentSysPowerStatusread-onlymandatoryIndicates if the system is currently powered on, off, or in sleep state.
1.3.6.1.4.1.2.3.51.3.5.1.2ScalarpowerOnHoursread-onlymandatoryNumber of hours the system has been powered on.
1.3.6.1.4.1.2.3.51.3.5.1.3ScalarrestartCountread-onlymandatoryNumber of times the system has been restarted.
1.3.6.1.4.1.2.3.51.3.5.1.4ScalarsystemStateread-onlymandatoryShows the current operational state of the system.
1.3.6.1.4.1.2.3.51.3.5.2NodepowerSysConfig
1.3.6.1.4.1.2.3.51.3.5.2.1ScalarpowerSysOffDelayread-writemandatoryThe number of 1 second interval the IMM will wait before powering off the system.
1.3.6.1.4.1.2.3.51.3.5.2.2ScalarpowerSysOnClockSettingread-writemandatoryThe clock setting used to determine when the IMM will power on the system. The examples and the format follow: (1)For example to set the value so the system wi…
1.3.6.1.4.1.2.3.51.3.5.3NodepowerOffSystemControl
1.3.6.1.4.1.2.3.51.3.5.3.1ScalarpowerOffWithOsShutdownwrite-onlymandatoryPower off the system after performing a OS shutdown.
1.3.6.1.4.1.2.3.51.3.5.3.2ScalarpowerOffImmediatelywrite-onlymandatoryPower off the system immediately.
1.3.6.1.4.1.2.3.51.3.5.4NodepowerOnSystemControl
1.3.6.1.4.1.2.3.51.3.5.4.2ScalarpowerOnImmediatelywrite-onlymandatoryPower on the system immediately.
1.3.6.1.4.1.2.3.51.3.5.5NodepowerCyclingSchedule
1.3.6.1.4.1.2.3.51.3.5.5.1ScalarschedulePowerOffWithOsShutdownread-writemandatoryPower Off the system after performing a OS shutdown at specified time and day of the week. Example: Monday,09:00 field contents range _____ ________ _____ 1 da…
1.3.6.1.4.1.2.3.51.3.5.5.2ScalarschedulePowerOnSystemread-writemandatoryPower On the system at specified time and day of the week. Example: Monday,09:00 field contents range _____ ________ _____ 1 day EveryDay,Sunday,Monday,Tuesday…
1.3.6.1.4.1.2.3.51.3.5.6NodepowerControlSleep
1.3.6.1.4.1.2.3.51.3.5.6.1ScalarpowerEnterSleepwrite-onlymandatorySet system to enter power sleep state. The power sleep control actions will not work if the Sleep function is not enabled.
1.3.6.1.4.1.2.3.51.3.5.6.2ScalarpowerExitSleepwrite-onlymandatorySet system to exit power sleep state. The power sleep control actions will not work if the Sleep function is not enabled.
1.3.6.1.4.1.2.3.51.3.5.7NodepowerRestorePolicyControl
1.3.6.1.4.1.2.3.51.3.5.7.1ScalarpowerRestorePolicyread-writemandatoryPower Restore Policy determines the mode of operation if a power loss occurs. This setting can also be configured via BIOS F1 setup. alwaysoff: System will rem…
1.3.6.1.4.1.2.3.51.3.5.7.2ScalarpowerRestoreDelayread-writemandatoryPower Restore Delay is executed when power restore policy is set to alwayson or restore (if the previous state was power-on). disabled: Power on the server wit…
1.3.6.1.4.1.2.3.51.3.6NoderestartReset
1.3.6.1.4.1.2.3.51.3.6.1ScalarshutdownOsThenRestartwrite-onlymandatoryShutdown the OS and then restart the system and boot the OS.
1.3.6.1.4.1.2.3.51.3.6.2ScalarrestartSystemImmediatelywrite-onlymandatoryRestart the system immediately and then the boot OS.
1.3.6.1.4.1.2.3.51.3.6.3ScalarrestartSPImmediatelywrite-onlymandatoryRestart the IMM immediately.
1.3.6.1.4.1.2.3.51.3.6.4ScalarresetSPConfigAndRestartwrite-onlymandatoryWill cause all the IMM information to be reset to it's initial factory defaults(all previous configuration information is lost) and the IMM will be re-started.
1.3.6.1.4.1.2.3.51.3.6.5ScalarscheduleShutdownOsThenRestartread-writemandatoryShutdown the OS and then restart the system and boot the OS at specified Time and Day of the week. Example: Monday,09:00 field contents range _____ ________ __…
1.3.6.1.4.1.2.3.51.3.6.6ScalarresetPowerScheduleswrite-onlymandatoryreset all power schedules. schedulePowerOnSystem,schedulePowerOffWithOsShutdown, scheduleShutdownOsThenRestart. This does not reset powerSysOnClockSetting
1.3.6.1.4.1.2.3.51.3.6.7ScalarbootServerF1Setupwrite-onlymandatoryBoot the server to UEFI F1 Setup. If the server is powered on when the action is initiated, the server will be powered off with an OS shutdown, then powered ba…
1.3.6.1.4.1.2.3.51.3.7NodefirmwareUpdate
1.3.6.1.4.1.2.3.51.3.7.1ScalarfirmwareUpdateTargetread-writemandatoryTarget module whose firmware will be updated.
1.3.6.1.4.1.2.3.51.3.7.2ScalarfirmwareUpdateTftpServerread-writemandatoryIP address of the TFTP server where the firmware file resides. The address must be entered in a dotted decimal IP string (eg. 9.37.44.2).
1.3.6.1.4.1.2.3.51.3.7.3ScalarfirmwareUpdateFileNameread-writemandatoryFile name of the firmware file.
1.3.6.1.4.1.2.3.51.3.7.4ScalarfirmwareUpdateStartwrite-onlymandatoryStart updating the firmware of the specified IMM Card. Note 1: The firmware update might take up to several minutes to complete. Do not reset the IMM Card unti…
1.3.6.1.4.1.2.3.51.3.7.5ScalarfirmwareUpdateStatusread-onlymandatoryGet the status of the last firmware update which was initiated through SNMP method.
1.3.6.1.4.1.2.3.51.3.8NodeserviceAdvisor
1.3.6.1.4.1.2.3.51.3.8.1NodeautoCallHomeSetup
1.3.6.1.4.1.2.3.51.3.8.1.1ScalaracceptLicenseAgreementread-writemandatoryAccept Terms and Conditions of Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to suppor…
1.3.6.1.4.1.2.3.51.3.8.1.2ScalarserviceAdvisorEnableread-writemandatoryDisable/Enable Call Home Support. The User Agreement must be accepted and the contact information must be set before the Call Home Support function of Service …
1.3.6.1.4.1.2.3.51.3.8.2NodeserviceSupportCenter
1.3.6.1.4.1.2.3.51.3.8.2.1ScalaribmSupportCenterread-writemandatoryThe country code for the Support Center. 2 character ISO country code.
1.3.6.1.4.1.2.3.51.3.8.3NodecontactInformation
1.3.6.1.4.1.2.3.51.3.8.3.1ScalarcompanyNameread-writemandatoryThe organization/company name of the contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.3.8.3.2ScalarcontactNameread-writemandatoryThe name of the contact person.1-30 characters.
1.3.6.1.4.1.2.3.51.3.8.3.3ScalarphoneNumberread-writemandatoryThe phone of the contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.3.8.3.4ScalaremailAddressread-writemandatoryThe email of the contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum). The userid can be alphanumeric characters, '.…
1.3.6.1.4.1.2.3.51.3.8.3.5Scalaraddressread-writemandatoryThe address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. …
1.3.6.1.4.1.2.3.51.3.8.3.6Scalarcityread-writemandatoryThe city of the machine location. 1-30 characters.
1.3.6.1.4.1.2.3.51.3.8.3.7Scalarstateread-writemandatoryThe state of the machine location. 2-3 characters.
1.3.6.1.4.1.2.3.51.3.8.3.8ScalarpostalCoderead-writemandatoryThe postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid.
1.3.6.1.4.1.2.3.51.3.8.3.9ScalarphoneExtensionread-writemandatoryThe phone extension of the contact person. 30 characters maximum.
1.3.6.1.4.1.2.3.51.3.8.3.10ScalaraltContactNameread-writemandatoryThe name of the alternate contact person. 1-30 characters.
1.3.6.1.4.1.2.3.51.3.8.3.11ScalaraltPhoneNumberread-writemandatoryThe phone of the alternate contact person. 5-30 characters.
1.3.6.1.4.1.2.3.51.3.8.3.12ScalaraltPhoneExtensionread-writemandatoryThe phone extension of the alternate contact person. 30 characters maximum.
1.3.6.1.4.1.2.3.51.3.8.3.13ScalaraltEmailAddressread-writemandatoryThe email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum). The userid can be alphanumeric char…
1.3.6.1.4.1.2.3.51.3.8.3.14ScalarmachineLocationPhoneNumberread-writemandatoryThe phone of the physical location where the compuer system resides. 5-30 characters.
1.3.6.1.4.1.2.3.51.3.8.4NodehttpProxyConfig
1.3.6.1.4.1.2.3.51.3.8.4.1ScalarhttpProxyEnableread-writemandatoryDisable/Enable of the HTTP Proxy. Select Enable to use the proxy for call home connections from the IMM to the Service Center. HTTP Proxy is used by the IMM wh…
1.3.6.1.4.1.2.3.51.3.8.4.2ScalarhttpProxyLocationread-writemandatoryFully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters.
1.3.6.1.4.1.2.3.51.3.8.4.3ScalarhttpProxyPortread-writemandatoryThe port number of the HTTP Proxy. An integer value from 1 to 65535.
1.3.6.1.4.1.2.3.51.3.8.4.4ScalarhttpProxyUserNameread-writemandatoryUser Name of the HTTP Proxy. A maximum of 30 characters string without spaces.
1.3.6.1.4.1.2.3.51.3.8.4.5ScalarhttpProxyPasswordread-writemandatoryPassword of the HTTP Proxy. A maximum of 15 characters string without spaces.
1.3.6.1.4.1.2.3.51.3.8.5NodeactivityLogs
1.3.6.1.4.1.2.3.51.3.8.5.1TableactivityLogTablenot-accessiblemandatoryTable of Service Advisor Activity Log entries information. This table displays events that were generated by the system or user that are called home. The entri…
1.3.6.1.4.1.2.3.51.3.8.5.1.1RowactivityLogEntrynot-accessiblemandatoryActivity Log table entry. Each entry has the result of the call-home attempt, the service number assigned for the issue by the Support Center, the event ID, ev…
1.3.6.1.4.1.2.3.51.3.8.5.1.1.1ColumnactivityLogIndexread-onlymandatoryThe Activity Log index number. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.8.5.1.1.2ColumnactivityLogStringread-onlymandatoryA string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and no…
1.3.6.1.4.1.2.3.51.3.8.5.1.1.3ColumnactivityLogAcknowledgeread-writemandatoryThe acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of…
1.3.6.1.4.1.2.3.51.3.8.5.1.1.4ColumnactivityLogAttributeread-onlymandatoryA string of data detailing one Activity Log entry's attribute. It contains states of both calling the Support Center and FTP/TFTP Server. A PENDING indicates t…
1.3.6.1.4.1.2.3.51.3.8.6NodeautoFTPSetup
1.3.6.1.4.1.2.3.51.3.8.6.1ScalarautoFTPCallModeread-writemandatoryThis field specifies the automated problem reporting mode. Automated problem reporting mode allows the IMM to automatically put service data to a specified ser…
1.3.6.1.4.1.2.3.51.3.8.6.2ScalarautoFTPCallAddrread-writemandatoryThis field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address.
1.3.6.1.4.1.2.3.51.3.8.6.3ScalarautoFTPCallPortread-writemandatoryThis field specifies the port on remote FTP/TFTP server for data transmission.
1.3.6.1.4.1.2.3.51.3.8.6.4ScalarautoFTPCallUserIDread-writemandatoryThis field specifies the user account to login remote FTP server.
1.3.6.1.4.1.2.3.51.3.8.6.5ScalarautoFTPCallPasswordread-writemandatoryThis field specifies the password to login remote FTP server.
1.3.6.1.4.1.2.3.51.3.8.7NodecallHomeExclusionEvents
1.3.6.1.4.1.2.3.51.3.8.7.1TablereadCallHomeExclusionEventTablenot-accessiblemandatoryTable of Call Home Exclusion Event entries information.
1.3.6.1.4.1.2.3.51.3.8.7.1.1RowreadCallHomeExclusionEventEntrynot-accessiblemandatoryCall Home Exclusion Event table entry
1.3.6.1.4.1.2.3.51.3.8.7.1.1.1ColumnreadCallHomeExclusionEventIndexread-onlymandatoryThe index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.8.7.1.1.2ColumnreadCallHomeExclusionEventIDread-onlymandatoryThe Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries.
1.3.6.1.4.1.2.3.51.3.8.7.2ScalaraddCallHomeExclusionEventread-writemandatoryAdd one call home Event ID into the Call Home Exclusion List. The Event ID is an 16-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. The…
1.3.6.1.4.1.2.3.51.3.8.7.3ScalarrmCallHomeExclusionEventread-writemandatoryRemove one call home Event ID from the Call Home Exclusion List. The Event ID is an 16-digit hexadecimal number (0-F) with an optional prefix of '0x' or '0X'. …
1.3.6.1.4.1.2.3.51.3.8.7.4ScalarrmAllCallHomeExclusionEventread-writemandatoryRemove all Event IDs from the Call Home Exclusion List. If Service Advisor Terms and Conditions are accepted, events on the exclusion list can be removed. NOTE…
1.3.6.1.4.1.2.3.51.3.8.8NodetestCallHome
1.3.6.1.4.1.2.3.51.3.8.8.1ScalargenerateTestCallHomewrite-onlymandatoryGenerate a Test Call Home.
1.3.6.1.4.1.2.3.51.3.9Nodescaling
1.3.6.1.4.1.2.3.51.3.9.1NodescalableComplex
1.3.6.1.4.1.2.3.51.3.9.1.1ScalarscalableComplexIdentifierread-onlymandatoryThe unique numeric identifier for a complex.
1.3.6.1.4.1.2.3.51.3.9.1.2ScalarscalableComplexNumPartitionsread-onlymandatoryThe number of partitions currently defined for this complex.
1.3.6.1.4.1.2.3.51.3.9.1.3ScalarscalableComplexNumNodesread-onlymandatoryThe number of nodes existing in this complex, regardless of their assignment to any given partition. For ITEs or blabde, the physical slot location of the node…
1.3.6.1.4.1.2.3.51.3.9.1.4ScalarscalableComplexClearwrite-onlymandatoryThis clears all partition information related to the complex. Any nodes associated with the complex are no longer assigned to any partitions. All nodes in the …
1.3.6.1.4.1.2.3.51.3.9.2NodescalableComplexPartition
1.3.6.1.4.1.2.3.51.3.9.2.1TablescalableComplexPartitionTablenot-accessiblemandatoryTable of scalable complex partition information.
1.3.6.1.4.1.2.3.51.3.9.2.1.1RowscalableComplexPartitionEntrynot-accessiblemandatoryScalable complex partition information.
1.3.6.1.4.1.2.3.51.3.9.2.1.1.1ColumnscalableComplexPartitionIdentifierread-onlymandatoryThe unique numeric identifier for a partition defined within a complex installed in the chassis.
1.3.6.1.4.1.2.3.51.3.9.2.1.1.2ColumnscalableComplexPartitionModeread-writemandatoryThe currently configured mode of this partition. It is recommended that a partition be powered off prior to modification of the mode. In addition, switching a …
1.3.6.1.4.1.2.3.51.3.9.2.1.1.3ColumnscalableComplexPartitionPriNodeKeyread-onlymandatoryThe Node Key for the primary node in the partition. The Node Key is used to select partition for some actions that affect all nodes in the partition.
1.3.6.1.4.1.2.3.51.3.9.2.1.1.4ColumnscalableComplexPartitionNumNodesread-onlymandatoryThe number of nodes currently defined for this partition.
1.3.6.1.4.1.2.3.51.3.9.2.1.1.5ColumnscalableComplexPartitionStatusread-onlymandatoryThe current power status of this partition when the partition has a valid partition configuration. However, in the event the partition reports a partition cons…
1.3.6.1.4.1.2.3.51.3.9.2.2ScalarscalableComplexPartitionSelectwrite-onlymandatoryThis Node Key of Primary node of the partition is used to select the partition for which a specific action will be taken
1.3.6.1.4.1.2.3.51.3.9.2.3ScalarscalableComplexPartitionActionwrite-onlymandatoryThis object allows various actions to be taken in relation to a particular partition in a given complex. delete(1) - Deletes the partition from the complex. Al…
1.3.6.1.4.1.2.3.51.3.9.3NodescalableComplexPartitionCreate
1.3.6.1.4.1.2.3.51.3.9.3.1TablescalableComplexPartitionCreateTablenot-accessiblemandatoryTable used to identify the nodes to be used in create of a partition. The nodes are identified by Node key. The first node listed will be the primary node.
1.3.6.1.4.1.2.3.51.3.9.3.1.1RowscalableComplexPartitionCreateEntrynot-accessiblemandatoryNode information for partition creation.
1.3.6.1.4.1.2.3.51.3.9.3.1.1.1ColumnscalableComplexPartitionCreateIndexread-onlymandatoryThe table index.
1.3.6.1.4.1.2.3.51.3.9.3.1.1.2ColumnscalableComplexPartitionCreateNodeKeyread-writemandatoryThe Node Key for a node included in the partition to be created. The first Node Key in the table is used will be the primary node in the partition to be create…
1.3.6.1.4.1.2.3.51.3.9.3.2ScalarscalableComplexPartitionActionCreatewrite-onlymandatoryThis object is used to request creation of a new partition, using the nodes listed in the scalableComplexPartitionCreateTable. None of the systems can be part …
1.3.6.1.4.1.2.3.51.3.9.4NodescalableComplexNode
1.3.6.1.4.1.2.3.51.3.9.4.1TablescalableComplexNodeTablenot-accessiblemandatoryTable of scalable complex node information. This table provides information and control actions related to the nodes installed in the chassis. Complex, partiti…
1.3.6.1.4.1.2.3.51.3.9.4.1.1RowscalableComplexNodeEntrynot-accessiblemandatoryScalable complex node information.
1.3.6.1.4.1.2.3.51.3.9.4.1.1.1ColumnscalableComplexNodeIndexread-onlymandatoryThe node table index.
1.3.6.1.4.1.2.3.51.3.9.4.1.1.2ColumnscalableComplexNodeSerialNumberread-onlymandatoryThe machine serial number of the node which identifies the node. Note that uniqueness is not guaranteed.
1.3.6.1.4.1.2.3.51.3.9.4.1.1.3ColumnscalableComplexNodeKeyread-onlymandatoryThe Node Key for the node. The Node Key is used to select the node for some particular action.
1.3.6.1.4.1.2.3.51.3.9.4.1.1.4ColumnscalableComplexNodePartitionIDread-onlymandatoryFor an assigned node, the identifier of the partition this node is related to. For an unassigned node, this object has no meaning.
1.3.6.1.4.1.2.3.51.3.9.4.1.1.5ColumnscalableComplexNodeRoleread-onlymandatoryIndicates if the node is assigned to a partition, and if so, provides an indication of whether the node is the primary node of the partition or not.
1.3.6.1.4.1.2.3.51.3.9.4.1.1.6ColumnscalableComplexNodeNumPortsread-onlymandatoryThe number of remote nodes that this node has links to.
1.3.6.1.4.1.2.3.51.3.9.4.2ScalarscalableComplexNodeSelectwrite-onlymandatoryThis Node Key is used to select the node for which a specific action will be taken
1.3.6.1.4.1.2.3.51.3.9.4.3ScalarscalableComplexNodeActionwrite-onlymandatoryThe actions that can be applied to an unassigned node. The current state is provided by the scalableComplexNodeState object.
1.3.6.1.4.1.2.3.51.3.9.4.4ScalarscalableComplexNodeAutoCreatewrite-onlymandatoryThis object is used to create a partition from all of the nodes in the complex. None of the systems can be in a partition and all the systems in the complex mu…
1.3.6.1.4.1.2.3.51.3.9.5NodescalableComplexNodePort
1.3.6.1.4.1.2.3.51.3.9.5.1TablescalableComplexNodePortTablenot-accessiblemandatoryTable of scalable complex node port information which provides details related to the port connectivity. Complex, partition and node information and control ar…
1.3.6.1.4.1.2.3.51.3.9.5.1.1RowscalableComplexNodePortEntrynot-accessiblemandatoryScalable complex node port information.
1.3.6.1.4.1.2.3.51.3.9.5.1.1.1ColumnscalableComplexNodePortIndexread-onlymandatoryThe Node Port table index.
1.3.6.1.4.1.2.3.51.3.9.5.1.1.2ColumnscalableComplexNodePortNumread-onlymandatoryThe port number of a port on this node. Note that this port number is 0-based, but since it is used as the table index (0 is not allowed), it will be presented…
1.3.6.1.4.1.2.3.51.3.9.5.1.1.3ColumnscalableComplexNodePortRemNodeKeyread-onlymandatoryThe Node Key for the remote node.
1.3.6.1.4.1.2.3.51.3.9.5.1.1.4ColumnscalableComplexNodePortRemNumread-onlymandatoryThe zero-based port number of the remote port.
1.3.6.1.4.1.2.3.51.3.9.5.1.1.5ColumnscalableComplexNodePortStatusread-onlymandatoryThe current status of the port.
1.3.6.1.4.1.2.3.51.3.9.5.1.1.6ColumnscalableComplexNodePortTyperead-onlymandatoryThe port type.
Type Definitions
NameSyntaxStatusDescription
InetAddressIPv6OCTET STRING (SIZE (16)) EntryStatus ::= INTEGER { valid(1), createRequest(2), underCreation(3), invalid(4) }currentRepresents an IPv6 network address. Since MIB browsers may require different formats, the address is expected to be the 16 byte address in network-byte order, and shortened formats such as 0::0 are not accepted in SET o…