MIB Viewer

IMMALERT-MIB

53 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1212OBJECT-TYPE
RFC1155-SMICounter enterprises IpAddress TimeTicks
RFC1213-MIBDisplayString mib-2
OIDNameAccessStatusDescription
1.3.6.1.4.1.2Nodeibm
1.3.6.1.4.1.2.6NodeibmProd
1.3.6.1.4.1.2.6.158NodesupportProcessor
1.3.6.1.4.1.2.6.158.5NodeimmalertMIB
1.3.6.1.4.1.2.6.158.5.0NodeibmSpTrapTempCCritical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.2.6.158.5.1NodeibmSpTrapVoltCCritical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.2.6.158.5.1Nodeimmtrapg
1.3.6.1.4.1.2.6.158.5.1.1ScalaraltDateTimeread-onlymandatoryTimestamp of Local Date and Time when alert was generated
1.3.6.1.4.1.2.6.158.5.1.3ScalaraltSpTxtIdread-onlymandatorySP System Identification - Text Identification
1.3.6.1.4.1.2.6.158.5.1.5ScalaraltSysUuidread-onlymandatoryHost System UUID(Universal Unique ID)
1.3.6.1.4.1.2.6.158.5.1.6ScalaraltSysSernread-onlymandatoryHost System Serial Number
1.3.6.1.4.1.2.6.158.5.1.8ScalaraltPriorityread-onlymandatoryAlert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery(8)
1.3.6.1.4.1.2.6.158.5.1.9ScalaraltMsgTextread-onlymandatoryAlert Message Text
1.3.6.1.4.1.2.6.158.5.1.10ScalaraltMsgIDread-onlymandatoryAlert Message ID
1.3.6.1.4.1.2.6.158.5.1.11ScalaraltMsgIDPrefixread-onlymandatoryAlert Message ID
1.3.6.1.4.1.2.6.158.5.1.12ScalaraltHostContactread-onlymandatoryHost Contact
1.3.6.1.4.1.2.6.158.5.1.13ScalaraltHostLocationread-onlymandatoryHost Location
1.3.6.1.4.1.2.6.158.5.1.14ScalaraltHostRoomIDread-onlymandatoryHost Location - Room ID
1.3.6.1.4.1.2.6.158.5.1.15ScalaraltHostRackIDread-onlymandatoryHost Location - Rack ID
1.3.6.1.4.1.2.6.158.5.1.16ScalaraltHostLowestUposread-onlymandatoryHost Location - Lowest U-position
1.3.6.1.4.1.2.6.158.5.1.17ScalaraltHostBladeBayread-onlymandatoryHost Location - BladeBay
1.3.6.1.4.1.2.6.158.5.1.18ScalaraltEventIDread-onlymandatoryEvent Identifier
1.3.6.1.4.1.2.6.158.5.1.19ScalaraltServiceableread-onlymandatoryServiceability information.
1.3.6.1.4.1.2.6.158.5.1.20ScalaraltTestread-onlymandatoryThis event generated for test purposes.
1.3.6.1.4.1.2.6.158.5.1.21ScalaraltFailingFRUsread-onlymandatoryOrdered list of Failing FRU Numbers, separated by commas.
1.3.6.1.4.1.2.6.158.5.1.22ScalaraltHostMTMread-onlymandatoryMachine Type and Model for failing host.
1.3.6.1.4.1.2.6.158.5.1.23ScalaraltAuxDataread-onlymandatoryAuxiliary data that may be included for some events.
1.3.6.1.4.1.2.6.158.5.4NodeibmSpTrapPowerCCritical Alert: Power failure.
1.3.6.1.4.1.2.6.158.5.5NodeibmSpTrapHdCCritical Alert: Hard disk drive failure.
1.3.6.1.4.1.2.6.158.5.9NodeibmSpTrapRdpsCCritical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.2.6.158.5.10NodeibmSpTrapRdpsNNon-Critical Alert: Redundant Power Supply failure.
1.3.6.1.4.1.2.6.158.5.11NodeibmSpTrapFanCCritical Alert: Single Fan failure.
1.3.6.1.4.1.2.6.158.5.12NodeibmSpTrapTempNNon-Critical Alert: Temperature threshold exceeded.
1.3.6.1.4.1.2.6.158.5.13NodeibmSpTrapVoltNNon-Critical Alert: Voltage threshold exceeded.
1.3.6.1.4.1.2.6.158.5.21NodeibmSpTrapOsToSSystem Alert: OS Timeout value exceeded.
1.3.6.1.4.1.2.6.158.5.22NodeibmSpTrapAppSSystem Alert: Application Alert. Refer to Message ID for specific condition.
1.3.6.1.4.1.2.6.158.5.23NodeibmSpTrapPoffSSystem Alert: Power Off.
1.3.6.1.4.1.2.6.158.5.24NodeibmSpTrapPonSSystem Alert: Power On.
1.3.6.1.4.1.2.6.158.5.25NodeibmSpTrapBootSSystem Alert: System Boot Failure.
1.3.6.1.4.1.2.6.158.5.26NodeibmSpTrapLdrToSSystem Alert: OS Loader Timeout.
1.3.6.1.4.1.2.6.158.5.27NodeibmSpTrapPFASSystem Alert: Predictive Failure Analysis(PFA) information.
1.3.6.1.4.1.2.6.158.5.30NodeibmSpTrapRLoginSev-Off Alert: Event Remote Login.
1.3.6.1.4.1.2.6.158.5.35NodeibmSpTrapSysLogSSystem Alert: System Log 75% full.
1.3.6.1.4.1.2.6.158.5.36NodeibmSpTrapIhcCCritical Alert: Incompatible hardware configuration.
1.3.6.1.4.1.2.6.158.5.37NodeibmSpTrapNwChangeSSystem Alert: Network change notification.
1.3.6.1.4.1.2.6.158.5.40NodeibmSpTrapCPUCCritical Alert: CPU Error.
1.3.6.1.4.1.2.6.158.5.41NodeibmSpTrapMemoryCCritical Alert: Memory Error.
1.3.6.1.4.1.2.6.158.5.42NodeibmSpTrapCPUNNon-Critical Alert: CPU Error.
1.3.6.1.4.1.2.6.158.5.43NodeibmSpTrapMemoryNNon-Critical Alert: Memory Error.
1.3.6.1.4.1.2.6.158.5.50NodeibmSpTrapHardwareCCritical Alert: Other Failure - refer to Message ID for specific condition.
1.3.6.1.4.1.2.6.158.5.60NodeibmSpTrapHardwareNNon-Critical Alert: Warning - refer to Message ID for specific condition.
1.3.6.1.4.1.2.6.158.5.164NodeibmSpTrapPowerNNon-Critical Alert: Power.
1.3.6.1.4.1.2.6.158.5.165NodeibmSpTrapFanNNon-Critical Alert: Fan Error.