IMMALERT-MIB
53 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter enterprises IpAddress TimeTicks |
| RFC1213-MIB | DisplayString mib-2 |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2 | Nodeibm | |||
| 1.3.6.1.4.1.2.6 | NodeibmProd | |||
| 1.3.6.1.4.1.2.6.158 | NodesupportProcessor | |||
| 1.3.6.1.4.1.2.6.158.5 | NodeimmalertMIB | |||
| 1.3.6.1.4.1.2.6.158.5.0 | NodeibmSpTrapTempC | Critical Alert: Temperature threshold exceeded. | ||
| 1.3.6.1.4.1.2.6.158.5.1 | NodeibmSpTrapVoltC | Critical Alert: Voltage threshold exceeded. | ||
| 1.3.6.1.4.1.2.6.158.5.1 | Nodeimmtrapg | |||
| 1.3.6.1.4.1.2.6.158.5.1.1 | ScalaraltDateTime | read-only | mandatory | Timestamp of Local Date and Time when alert was generated |
| 1.3.6.1.4.1.2.6.158.5.1.3 | ScalaraltSpTxtId | read-only | mandatory | SP System Identification - Text Identification |
| 1.3.6.1.4.1.2.6.158.5.1.5 | ScalaraltSysUuid | read-only | mandatory | Host System UUID(Universal Unique ID) |
| 1.3.6.1.4.1.2.6.158.5.1.6 | ScalaraltSysSern | read-only | mandatory | Host System Serial Number |
| 1.3.6.1.4.1.2.6.158.5.1.8 | ScalaraltPriority | read-only | mandatory | Alert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery(8) |
| 1.3.6.1.4.1.2.6.158.5.1.9 | ScalaraltMsgText | read-only | mandatory | Alert Message Text |
| 1.3.6.1.4.1.2.6.158.5.1.10 | ScalaraltMsgID | read-only | mandatory | Alert Message ID |
| 1.3.6.1.4.1.2.6.158.5.1.11 | ScalaraltMsgIDPrefix | read-only | mandatory | Alert Message ID |
| 1.3.6.1.4.1.2.6.158.5.1.12 | ScalaraltHostContact | read-only | mandatory | Host Contact |
| 1.3.6.1.4.1.2.6.158.5.1.13 | ScalaraltHostLocation | read-only | mandatory | Host Location |
| 1.3.6.1.4.1.2.6.158.5.1.14 | ScalaraltHostRoomID | read-only | mandatory | Host Location - Room ID |
| 1.3.6.1.4.1.2.6.158.5.1.15 | ScalaraltHostRackID | read-only | mandatory | Host Location - Rack ID |
| 1.3.6.1.4.1.2.6.158.5.1.16 | ScalaraltHostLowestUpos | read-only | mandatory | Host Location - Lowest U-position |
| 1.3.6.1.4.1.2.6.158.5.1.17 | ScalaraltHostBladeBay | read-only | mandatory | Host Location - BladeBay |
| 1.3.6.1.4.1.2.6.158.5.1.18 | ScalaraltEventID | read-only | mandatory | Event Identifier |
| 1.3.6.1.4.1.2.6.158.5.1.19 | ScalaraltServiceable | read-only | mandatory | Serviceability information. |
| 1.3.6.1.4.1.2.6.158.5.1.20 | ScalaraltTest | read-only | mandatory | This event generated for test purposes. |
| 1.3.6.1.4.1.2.6.158.5.1.21 | ScalaraltFailingFRUs | read-only | mandatory | Ordered list of Failing FRU Numbers, separated by commas. |
| 1.3.6.1.4.1.2.6.158.5.1.22 | ScalaraltHostMTM | read-only | mandatory | Machine Type and Model for failing host. |
| 1.3.6.1.4.1.2.6.158.5.1.23 | ScalaraltAuxData | read-only | mandatory | Auxiliary data that may be included for some events. |
| 1.3.6.1.4.1.2.6.158.5.4 | NodeibmSpTrapPowerC | Critical Alert: Power failure. | ||
| 1.3.6.1.4.1.2.6.158.5.5 | NodeibmSpTrapHdC | Critical Alert: Hard disk drive failure. | ||
| 1.3.6.1.4.1.2.6.158.5.9 | NodeibmSpTrapRdpsC | Critical Alert: Redundant Power Supply failure. | ||
| 1.3.6.1.4.1.2.6.158.5.10 | NodeibmSpTrapRdpsN | Non-Critical Alert: Redundant Power Supply failure. | ||
| 1.3.6.1.4.1.2.6.158.5.11 | NodeibmSpTrapFanC | Critical Alert: Single Fan failure. | ||
| 1.3.6.1.4.1.2.6.158.5.12 | NodeibmSpTrapTempN | Non-Critical Alert: Temperature threshold exceeded. | ||
| 1.3.6.1.4.1.2.6.158.5.13 | NodeibmSpTrapVoltN | Non-Critical Alert: Voltage threshold exceeded. | ||
| 1.3.6.1.4.1.2.6.158.5.21 | NodeibmSpTrapOsToS | System Alert: OS Timeout value exceeded. | ||
| 1.3.6.1.4.1.2.6.158.5.22 | NodeibmSpTrapAppS | System Alert: Application Alert. Refer to Message ID for specific condition. | ||
| 1.3.6.1.4.1.2.6.158.5.23 | NodeibmSpTrapPoffS | System Alert: Power Off. | ||
| 1.3.6.1.4.1.2.6.158.5.24 | NodeibmSpTrapPonS | System Alert: Power On. | ||
| 1.3.6.1.4.1.2.6.158.5.25 | NodeibmSpTrapBootS | System Alert: System Boot Failure. | ||
| 1.3.6.1.4.1.2.6.158.5.26 | NodeibmSpTrapLdrToS | System Alert: OS Loader Timeout. | ||
| 1.3.6.1.4.1.2.6.158.5.27 | NodeibmSpTrapPFAS | System Alert: Predictive Failure Analysis(PFA) information. | ||
| 1.3.6.1.4.1.2.6.158.5.30 | NodeibmSpTrapRLogin | Sev-Off Alert: Event Remote Login. | ||
| 1.3.6.1.4.1.2.6.158.5.35 | NodeibmSpTrapSysLogS | System Alert: System Log 75% full. | ||
| 1.3.6.1.4.1.2.6.158.5.36 | NodeibmSpTrapIhcC | Critical Alert: Incompatible hardware configuration. | ||
| 1.3.6.1.4.1.2.6.158.5.37 | NodeibmSpTrapNwChangeS | System Alert: Network change notification. | ||
| 1.3.6.1.4.1.2.6.158.5.40 | NodeibmSpTrapCPUC | Critical Alert: CPU Error. | ||
| 1.3.6.1.4.1.2.6.158.5.41 | NodeibmSpTrapMemoryC | Critical Alert: Memory Error. | ||
| 1.3.6.1.4.1.2.6.158.5.42 | NodeibmSpTrapCPUN | Non-Critical Alert: CPU Error. | ||
| 1.3.6.1.4.1.2.6.158.5.43 | NodeibmSpTrapMemoryN | Non-Critical Alert: Memory Error. | ||
| 1.3.6.1.4.1.2.6.158.5.50 | NodeibmSpTrapHardwareC | Critical Alert: Other Failure - refer to Message ID for specific condition. | ||
| 1.3.6.1.4.1.2.6.158.5.60 | NodeibmSpTrapHardwareN | Non-Critical Alert: Warning - refer to Message ID for specific condition. | ||
| 1.3.6.1.4.1.2.6.158.5.164 | NodeibmSpTrapPowerN | Non-Critical Alert: Power. | ||
| 1.3.6.1.4.1.2.6.158.5.165 | NodeibmSpTrapFanN | Non-Critical Alert: Fan Error. |