MIB Viewer

INTEGRATED-SERVICES-MIB

54 objects
The MIB module to describe the Integrated Services Protocol
Imported Objects
IF-MIBifIndex InterfaceIndex
SNMPv2-CONFMODULE-COMPLIANCE OBJECT-GROUP
SNMPv2-SMICounter32 Gauge32 Integer32 mib-2 MODULE-IDENTITY OBJECT-TYPE
SNMPv2-TCRowStatus TestAndIncr TEXTUAL-CONVENTION TimeInterval TruthValue
OIDNameAccessStatusDescription
1.3.6.1.2.1.52IdentityintSrvThe MIB module to describe the Integrated Services Protocol
1.3.6.1.2.1.52.1NodeintSrvObjects
1.3.6.1.2.1.52.1.1TableintSrvIfAttribTablenot-accessiblecurrentThe reservable attributes of the system's in- terfaces.
1.3.6.1.2.1.52.1.1.1RowintSrvIfAttribEntrynot-accessiblecurrentThe reservable attributes of a given inter- face.
1.3.6.1.2.1.52.1.1.1.1ColumnintSrvIfAttribAllocatedBitsread-onlycurrentThe number of bits/second currently allocated to reserved sessions on the interface.
1.3.6.1.2.1.52.1.1.1.2ColumnintSrvIfAttribMaxAllocatedBitsread-createcurrentThe maximum number of bits/second that may be allocated to reserved sessions on the inter- face.
1.3.6.1.2.1.52.1.1.1.3ColumnintSrvIfAttribAllocatedBufferread-onlycurrentThe amount of buffer space required to hold the simultaneous burst of all reserved flows on the interface.
1.3.6.1.2.1.52.1.1.1.4ColumnintSrvIfAttribFlowsread-onlycurrentThe number of reserved flows currently active on this interface. A flow can be created ei- ther from a reservation protocol (such as RSVP or ST-II) or via conf…
1.3.6.1.2.1.52.1.1.1.5ColumnintSrvIfAttribPropagationDelayread-createcurrentThe amount of propagation delay that this in- terface introduces in addition to that intro- diced by bit propagation delays.
1.3.6.1.2.1.52.1.1.1.6ColumnintSrvIfAttribStatusread-createcurrent'active' on interfaces that are configured for RSVP.
1.3.6.1.2.1.52.1.2TableintSrvFlowTablenot-accessiblecurrentInformation describing the reserved flows us- ing the system's interfaces.
1.3.6.1.2.1.52.1.2.1RowintSrvFlowEntrynot-accessiblecurrentInformation describing the use of a given in- terface by a given flow. The counter intSrvFlowPoliced starts counting at the in- stallation of the flow.
1.3.6.1.2.1.52.1.2.1.1ColumnintSrvFlowNumbernot-accessiblecurrentThe number of this flow. This is for SNMP In- dexing purposes only and has no relation to any protocol value.
1.3.6.1.2.1.52.1.2.1.2ColumnintSrvFlowTyperead-createcurrentThe type of session (IP4, IP6, IP6 with flow information, etc).
1.3.6.1.2.1.52.1.2.1.3ColumnintSrvFlowOwnerread-createcurrentThe process that installed this flow in the queue policy database.
1.3.6.1.2.1.52.1.2.1.4ColumnintSrvFlowDestAddrread-createcurrentThe destination address used by all senders in this session. This object may not be changed when the value of the RowStatus object is 'ac- tive'.
1.3.6.1.2.1.52.1.2.1.5ColumnintSrvFlowSenderAddrread-createcurrentThe source address of the sender selected by this reservation. The value of all zeroes in- dicates 'all senders'. This object may not be changed when the value…
1.3.6.1.2.1.52.1.2.1.6ColumnintSrvFlowDestAddrLengthread-createcurrentThe length of the destination address in bits. This is the CIDR Prefix Length, which for IP4 hosts and multicast addresses is 32 bits. This object may not be c…
1.3.6.1.2.1.52.1.2.1.7ColumnintSrvFlowSenderAddrLengthread-createcurrentThe length of the sender's address in bits. This is the CIDR Prefix Length, which for IP4 hosts and multicast addresses is 32 bits. This object may not be chan…
1.3.6.1.2.1.52.1.2.1.8ColumnintSrvFlowProtocolread-createcurrentThe IP Protocol used by a session. This ob- ject may not be changed when the value of the RowStatus object is 'active'.
1.3.6.1.2.1.52.1.2.1.9ColumnintSrvFlowDestPortread-createcurrentThe UDP or TCP port number used as a destina- tion port for all senders in this session. If the IP protocol in use, specified by intSrvResvFwdProtocol, is 50 (…
1.3.6.1.2.1.52.1.2.1.10ColumnintSrvFlowPortread-createcurrentThe UDP or TCP port number used as a source port for this sender in this session. If the IP protocol in use, specified by intSrvResvFwdProtocol is 50 (ESP) or …
1.3.6.1.2.1.52.1.2.1.11ColumnintSrvFlowFlowIdread-onlycurrentThe flow ID that this sender is using, if this is an IPv6 session.
1.3.6.1.2.1.52.1.2.1.12ColumnintSrvFlowInterfaceread-createcurrentThe ifIndex value of the interface on which this reservation exists.
1.3.6.1.2.1.52.1.2.1.13ColumnintSrvFlowIfAddrread-createcurrentThe IP Address on the ifEntry on which this reservation exists. This is present primarily to support those interfaces which layer multi- ple IP Addresses on th…
1.3.6.1.2.1.52.1.2.1.14ColumnintSrvFlowRateread-createcurrentThe Reserved Rate of the sender's data stream. If this is a Controlled Load service flow, this rate is derived from the Tspec rate parameter (r). If this is a …
1.3.6.1.2.1.52.1.2.1.15ColumnintSrvFlowBurstread-createcurrentThe size of the largest burst expected from the sender at a time. If this is less than the sender's advertised burst size, the receiver is asking the network t…
1.3.6.1.2.1.52.1.2.1.16ColumnintSrvFlowWeightread-createcurrentThe weight used to prioritize the traffic. Note that the interpretation of this object is implementation-specific, as implementations vary in their use of weig…
1.3.6.1.2.1.52.1.2.1.17ColumnintSrvFlowQueueread-createcurrentThe number of the queue used by this traffic. Note that the interpretation of this object is implementation-specific, as implementations vary in their use of q…
1.3.6.1.2.1.52.1.2.1.18ColumnintSrvFlowMinTUread-createcurrentThe minimum message size for this flow. The policing algorithm will treat smaller messages as though they are this size.
1.3.6.1.2.1.52.1.2.1.19ColumnintSrvFlowMaxTUread-createcurrentThe maximum datagram size for this flow that will conform to the traffic specification. This value cannot exceed the MTU of the interface.
1.3.6.1.2.1.52.1.2.1.20ColumnintSrvFlowBestEffortread-onlycurrentThe number of packets that were remanded to best effort service.
1.3.6.1.2.1.52.1.2.1.21ColumnintSrvFlowPolicedread-onlycurrentThe number of packets policed since the incep- tion of the flow's service.
1.3.6.1.2.1.52.1.2.1.22ColumnintSrvFlowDiscardread-createcurrentIf 'true', the flow is to incur loss when traffic is policed. If 'false', policed traff- ic is treated as best effort traffic.
1.3.6.1.2.1.52.1.2.1.23ColumnintSrvFlowServiceread-onlycurrentThe QoS service being applied to this flow.
1.3.6.1.2.1.52.1.2.1.24ColumnintSrvFlowOrderread-createcurrentIn the event of ambiguity, the order in which the classifier should make its comparisons. The row with intSrvFlowOrder=0 is tried first, and comparisons procee…
1.3.6.1.2.1.52.1.2.1.25ColumnintSrvFlowStatusread-createcurrent'active' for all active flows. This object may be used to install static classifier infor- mation, delete classifier information, or au- thorize such.
1.3.6.1.2.1.52.2NodeintSrvGenObjects
1.3.6.1.2.1.52.2.1ScalarintSrvFlowNewIndexread-writecurrentThis object is used to assign values to intSrvFlowNumber as described in 'Textual Con- ventions for SNMPv2'. The network manager reads the object, and then wri…
1.3.6.1.2.1.52.3NodeintSrvNotifications
1.3.6.1.2.1.52.4NodeintSrvConformance
1.3.6.1.2.1.52.4.1NodeintSrvGroups
1.3.6.1.2.1.52.4.1.1GroupintSrvIfAttribGroupcurrentThese objects are required for Systems sup- porting the Integrated Services Architecture.
1.3.6.1.2.1.52.4.1.2GroupintSrvFlowsGroupcurrentThese objects are required for Systems sup- porting the Integrated Services Architecture.
1.3.6.1.2.1.52.4.2NodeintSrvCompliances
1.3.6.1.2.1.52.4.2.1ComplianceintSrvComplianceread-onlycurrentThe compliance statement
Type Definitions
NameSyntaxStatusDescription
BitRateINTEGER (0..'7FFFFFFF'h)currentThe rate, in bits/second, that data may move in the context. Applicable contexts minimally include the speed of an interface or virtual circuit, the data rate of a (potentially aggre- gated) data flow, or the data rate …
BurstSizeINTEGER (0..'7FFFFFFF'h)currentThe number of octets of IP Data, including IP Headers, that a stream may send without concern for policing.
MessageSizeINTEGER (0..'7FFFFFFF'h)currentThe size of a message in bytes. This is used to specify the minimum and maximum size of a message along an integrated services route.
PortOCTET STRING (SIZE(2..4))currentThe value of the UDP or TCP Source or Destina- tion Port field, a virtual destination port or generalized port identifier used with the IPSEC Authentication Header or Encapsulating Security Payload, or other session dis…
ProtocolINTEGER (1..255)currentThe value of the IP Protocol field of an IP Datagram Header. This identifies the protocol layer above IP. For example, the value 6 is used for TCP and the value 17 is used for UDP. The values of this field are defined i…
QosServiceINTEGER { bestEffort (1), guaranteedDelay (2), controlledLoad (5) }currentThe class of service in use by a flow.
SessionNumberINTEGER (0..2147483647)currentThe Session Number convention is used for numbers identifying sessions or saved PATH or RESV information. It is a number in the range returned by a TestAndIncr variable, having no protocol meaning whatsoever but serving…
SessionTypeINTEGER (1..255)currentThe value of the C-Type field of a Session ob- ject, as defined in the RSVP specification. This value determines the lengths of octet strings and use of certain objects such as the 'port' variables. If the C-Type calls …