ISILON-TRAP-MIB
332 objects
Traps for Isilon Systems OneFS operating system.
Imported Objects
| ISILON-MIB | isilon |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | Counter64 Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.12124.250 | IdentityisilonTraps | Traps for Isilon Systems OneFS operating system. | ||
| 1.3.6.1.4.1.12124.250.10 | NodegroupStateTraps | |||
| 1.3.6.1.4.1.12124.250.10.1 | NodenodeStatus | |||
| 1.3.6.1.4.1.12124.250.10.1.3 | NotificationnodeStatusCrit | current | A critical node status event has occurred. | |
| 1.3.6.1.4.1.12124.250.10.1.7 | NotificationnodeStatusInfo | current | A node status event has occurred. | |
| 1.3.6.1.4.1.12124.250.10.2 | NodenodeExpStatus | |||
| 1.3.6.1.4.1.12124.250.10.2.3 | NotificationnodeExpStatusCrit | current | A disk-only node has gone offline and cannot be contacted by the cluster. | |
| 1.3.6.1.4.1.12124.250.10.3 | NodenodeShutdown | |||
| 1.3.6.1.4.1.12124.250.10.3.7 | NotificationnodeShutdownInfo | current | A node is being shut down or rebooted. | |
| 1.3.6.1.4.1.12124.250.10.4 | NodenodeShutdownFail | |||
| 1.3.6.1.4.1.12124.250.10.4.3 | NotificationnodeShutdownFailCrit | current | Shut down or reboot failed for a node. | |
| 1.3.6.1.4.1.12124.250.10.20 | NodenodeRebootCoalesced | |||
| 1.3.6.1.4.1.12124.250.10.20.7 | NotificationnodeRebootCoalescedInfo | current | A node is being rebooted. | |
| 1.3.6.1.4.1.12124.250.10.21 | NodenodeStatusCoalescing | |||
| 1.3.6.1.4.1.12124.250.10.21.3 | NotificationnodeStatusCoalescingCrit | current | Critical node status events are occurring | |
| 1.3.6.1.4.1.12124.250.10.21.5 | NotificationnodeStatusCoalescingWarn | current | Warning node status events are occurring | |
| 1.3.6.1.4.1.12124.250.11 | NodefilesystemTraps | |||
| 1.3.6.1.4.1.12124.250.11.1 | NodepartitionUsage | |||
| 1.3.6.1.4.1.12124.250.11.1.3 | NotificationpartitionUsageCrit | current | A partition is over the critical threshold percentage. | |
| 1.3.6.1.4.1.12124.250.11.1.5 | NotificationpartitionUsageWarn | current | A partition is over the warning threshold percentage. | |
| 1.3.6.1.4.1.12124.250.11.1.7 | NotificationpartitionUsageInfo | current | A partition is over the info threshold percentage. | |
| 1.3.6.1.4.1.12124.250.11.2 | NodeclusterStorageUsage | |||
| 1.3.6.1.4.1.12124.250.11.2.3 | NotificationclusterStorageUsageCrit | current | The /ifs partition is near capacity. | |
| 1.3.6.1.4.1.12124.250.11.2.5 | NotificationclusterStorageUsageWarn | current | The /ifs partition is near capacity. | |
| 1.3.6.1.4.1.12124.250.11.3 | NodefilesysError | |||
| 1.3.6.1.4.1.12124.250.11.3.3 | NotificationfilesysErrorCrit | current | A critical /ifs filesystem error has occurred | |
| 1.3.6.1.4.1.12124.250.11.3.5 | NotificationfilesysErrorWarn | current | A warning-level /ifs filesystem error has occurred | |
| 1.3.6.1.4.1.12124.250.11.3.7 | NotificationfilesysErrorInfo | current | An /ifs filesystem error has occurred. | |
| 1.3.6.1.4.1.12124.250.11.4 | NodediskPoolUsage | |||
| 1.3.6.1.4.1.12124.250.11.4.3 | NotificationdiskPoolUsageCrit | current | A disk pool is near capacity. | |
| 1.3.6.1.4.1.12124.250.11.4.5 | NotificationdiskPoolUsageWarn | current | A disk pool is near capacity. | |
| 1.3.6.1.4.1.12124.250.11.5 | NodediskPoolOldDbVersion | |||
| 1.3.6.1.4.1.12124.250.11.5.5 | NotificationdiskPoolOldDbVersionWarn | current | The SmartPools upgrade has not completed. | |
| 1.3.6.1.4.1.12124.250.11.6 | NodessdUsage | |||
| 1.3.6.1.4.1.12124.250.11.6.1 | NotificationssdUsageCrit | current | The SSD drives are at capacity. | |
| 1.3.6.1.4.1.12124.250.11.6.2 | NotificationssdUsageWarn | current | The SSD drives are near capacity. | |
| 1.3.6.1.4.1.12124.250.11.6.3 | NotificationssdUsageInfo | current | The SSD drives are near capacity. | |
| 1.3.6.1.4.1.12124.250.11.20 | NodefilesysCoalesce | |||
| 1.3.6.1.4.1.12124.250.11.20.3 | NotificationfilesysCoalesceCrit | current | Filesystem issues are occurring at a critical level | |
| 1.3.6.1.4.1.12124.250.11.20.5 | NotificationfilesysCoalesceWarn | current | Filesystem issues are occurring at a warning level | |
| 1.3.6.1.4.1.12124.250.12 | NodesmartQuotaTraps | |||
| 1.3.6.1.4.1.12124.250.12.1 | NodequotaThreshError | |||
| 1.3.6.1.4.1.12124.250.12.1.7 | NotificationquotaThreshErrorInfo | current | SmartQuotas threshold violation | |
| 1.3.6.1.4.1.12124.250.12.2 | NodequotaNotifyError | |||
| 1.3.6.1.4.1.12124.250.12.2.5 | NotificationquotaNotifyErrorWarn | current | SmartQuotas threshold notification failed | |
| 1.3.6.1.4.1.12124.250.12.3 | NodequotaError | |||
| 1.3.6.1.4.1.12124.250.12.3.5 | NotificationquotaErrorWarn | current | SmartQuotas error | |
| 1.3.6.1.4.1.12124.250.13 | NodesnapshotTraps | |||
| 1.3.6.1.4.1.12124.250.13.1 | NodesnapshotError | |||
| 1.3.6.1.4.1.12124.250.13.1.5 | NotificationsnapshotErrorWarn | current | Snapshot error | |
| 1.3.6.1.4.1.12124.250.13.2 | NodesnapshotReserve | |||
| 1.3.6.1.4.1.12124.250.13.2.3 | NotificationsnapshotReserveCrit | current | Snapshot reserve space is over its critical limit | |
| 1.3.6.1.4.1.12124.250.13.2.5 | NotificationsnapshotReserveWarn | current | Snapshot reserve space is over its warning limit | |
| 1.3.6.1.4.1.12124.250.14 | NodesyncIQTraps | |||
| 1.3.6.1.4.1.12124.250.14.1 | NodesiqEvent | |||
| 1.3.6.1.4.1.12124.250.14.1.3 | NotificationsiqEventCrit | current | SyncIQ event | |
| 1.3.6.1.4.1.12124.250.14.1.5 | NotificationsiqEventWarn | current | SyncIQ event | |
| 1.3.6.1.4.1.12124.250.14.2 | NodesiqError | |||
| 1.3.6.1.4.1.12124.250.14.2.5 | NotificationsiqErrorWarn | current | SyncIQ error | |
| 1.3.6.1.4.1.12124.250.14.20 | NodesiqPolicyCoalesced | |||
| 1.3.6.1.4.1.12124.250.14.20.3 | NotificationsiqPolicyCoalescedCrit | current | SyncIQ policy errors are occurring | |
| 1.3.6.1.4.1.12124.250.14.20.5 | NotificationsiqPolicyCoalescedWarn | current | SyncIQ policy errors are occurring | |
| 1.3.6.1.4.1.12124.250.14.21 | NodesiqTargetCoalesced | |||
| 1.3.6.1.4.1.12124.250.14.21.3 | NotificationsiqTargetCoalescedCrit | current | SyncIQ errors are occurring for target | |
| 1.3.6.1.4.1.12124.250.14.21.5 | NotificationsiqTargetCoalescedWarn | current | SyncIQ errors are occurring for target | |
| 1.3.6.1.4.1.12124.250.15 | NodesoftwareTraps | |||
| 1.3.6.1.4.1.12124.250.15.1 | NodejobEngineError | |||
| 1.3.6.1.4.1.12124.250.15.1.1 | NotificationjobEngineErrorEmerg | current | The cluster encountered one or more job failures. | |
| 1.3.6.1.4.1.12124.250.15.1.3 | NotificationjobEngineErrorCrit | current | The cluster encountered one or more job failures. | |
| 1.3.6.1.4.1.12124.250.15.1.5 | NotificationjobEngineErrorWarn | current | The cluster encountered one or more job failures. | |
| 1.3.6.1.4.1.12124.250.15.1.7 | NotificationjobEngineErrorInfo | current | The cluster encountered one or more job failures. | |
| 1.3.6.1.4.1.12124.250.15.2 | NodeflexProtectRunning | |||
| 1.3.6.1.4.1.12124.250.15.2.3 | NotificationflexProtectRunningCrit | current | Cluster is in need of restripe but FlexProtect is not running | |
| 1.3.6.1.4.1.12124.250.15.2.5 | NotificationflexProtectRunningWarn | current | Cluster is in need of restripe but FlexProtect is not running | |
| 1.3.6.1.4.1.12124.250.15.2.7 | NotificationflexProtectRunningInfo | current | Cluster is in need of restripe but FlexProtect is not running | |
| 1.3.6.1.4.1.12124.250.15.3 | NodeavscanInfectedFile | |||
| 1.3.6.1.4.1.12124.250.15.3.3 | NotificationavscanInfectedFileCrit | current | AVScan found an infected file | |
| 1.3.6.1.4.1.12124.250.15.3.5 | NotificationavscanInfectedFileWarn | current | AVScan found an infected file | |
| 1.3.6.1.4.1.12124.250.15.3.7 | NotificationavscanInfectedFileInfo | current | AVScan found an infected file | |
| 1.3.6.1.4.1.12124.250.15.5 | NodemcpProcFailed | |||
| 1.3.6.1.4.1.12124.250.15.5.5 | NotificationmcpProcFailedWarn | current | MCP reports a process has failed on a node | |
| 1.3.6.1.4.1.12124.250.15.6 | NodemcpProcKilled | |||
| 1.3.6.1.4.1.12124.250.15.6.5 | NotificationmcpProcKilledWarn | current | MCP killed a process on a node | |
| 1.3.6.1.4.1.12124.250.15.7 | NodelicenseExpiration | |||
| 1.3.6.1.4.1.12124.250.15.7.5 | NotificationlicenseExpirationWarn | current | One or more licenses has expired | |
| 1.3.6.1.4.1.12124.250.15.7.7 | NotificationlicenseExpirationInfo | current | One or more licenses is about to expire | |
| 1.3.6.1.4.1.12124.250.15.8 | NodefirmwareUpdateIncomplete | |||
| 1.3.6.1.4.1.12124.250.15.8.5 | NotificationfirmwareUpdateIncompleteWarn | current | A firmware update was not completely applied | |
| 1.3.6.1.4.1.12124.250.15.9 | NodetestEvent | |||
| 1.3.6.1.4.1.12124.250.15.9.3 | NotificationtestEventCrit | current | Test event | |
| 1.3.6.1.4.1.12124.250.15.10 | NodenodeCPU | |||
| 1.3.6.1.4.1.12124.250.15.10.5 | NotificationnodeCPUWarn | current | A node has exceeded the Warning-level CPU utilization. | |
| 1.3.6.1.4.1.12124.250.15.10.7 | NotificationnodeCPUInfo | current | A node has exceeded the Info-level CPU utilization. | |
| 1.3.6.1.4.1.12124.250.15.11 | NodemountdClientMountFailed | |||
| 1.3.6.1.4.1.12124.250.15.11.7 | NotificationmountdClientMountFailedInfo | current | Mountd denied client mount request | |
| 1.3.6.1.4.1.12124.250.15.12 | NodemountdHostLookupFailed | |||
| 1.3.6.1.4.1.12124.250.15.12.7 | NotificationmountdHostLookupFailedInfo | current | Mountd host lookup failed | |
| 1.3.6.1.4.1.12124.250.15.13 | NodemixedSedNonSedCluster | |||
| 1.3.6.1.4.1.12124.250.15.13.3 | NotificationmixedSedNonSedClusterCrit | current | Cluster contains a mix of encrypting nodes and non-encrypting nodes | |
| 1.3.6.1.4.1.12124.250.15.15 | NodenfsCookieTranslationFailed | |||
| 1.3.6.1.4.1.12124.250.15.15.1 | NotificationnfsCookieTranslationFailedInfo | current | 64bit to 32bit cookie translation failed | |
| 1.3.6.1.4.1.12124.250.16 | NodeavscanTraps | |||
| 1.3.6.1.4.1.12124.250.16.1 | NodeavscanNoServersConf | |||
| 1.3.6.1.4.1.12124.250.16.1.3 | NotificationavscanNoServersConfCrit | current | No ICAP servers configured for AVScan | |
| 1.3.6.1.4.1.12124.250.16.1.5 | NotificationavscanNoServersConfWarn | current | No ICAP servers configured for AVScan | |
| 1.3.6.1.4.1.12124.250.16.1.7 | NotificationavscanNoServersConfInfo | current | No ICAP servers configured for AVScan | |
| 1.3.6.1.4.1.12124.250.16.2 | NodeavscanError | |||
| 1.3.6.1.4.1.12124.250.16.2.3 | NotificationavscanErrorCrit | current | AVscan has encountered an error | |
| 1.3.6.1.4.1.12124.250.16.2.5 | NotificationavscanErrorWarn | current | AVscan has encountered an error | |
| 1.3.6.1.4.1.12124.250.16.2.7 | NotificationavscanErrorInfo | current | AVscan has encountered an error | |
| 1.3.6.1.4.1.12124.250.16.20 | NodeavscanCoalesced | |||
| 1.3.6.1.4.1.12124.250.16.20.3 | NotificationavscanCoalescedInfo | current | AVScan is detecting problems | |
| 1.3.6.1.4.1.12124.250.16.20.5 | NotificationavscanCoalescedWarn | current | AVScan is detecting problems | |
| 1.3.6.1.4.1.12124.250.16.20.7 | NotificationavscanCoalescedCrit | current | AVscan is detecting critical problems | |
| 1.3.6.1.4.1.12124.250.17 | NodenetProtoTraps | |||
| 1.3.6.1.4.1.12124.250.17.1 | NodeclockSkew | |||
| 1.3.6.1.4.1.12124.250.17.1.3 | NotificationclockSkewCrit | current | Windows ADS time skew outside limits. | |
| 1.3.6.1.4.1.12124.250.17.2 | NodesharePermsUpgradeFail | |||
| 1.3.6.1.4.1.12124.250.17.2.3 | NotificationsharePermsUpgradeFailCrit | current | Windows share permissions upgrade failed | |
| 1.3.6.1.4.1.12124.250.17.3 | NodewinTimeConnectivityLost | |||
| 1.3.6.1.4.1.12124.250.17.3.5 | NotificationwinTimeConnectivityLostWarn | current | Connectivity to the Windows Time server was lost | |
| 1.3.6.1.4.1.12124.250.17.4 | NodewinNetMapFull | |||
| 1.3.6.1.4.1.12124.250.17.4.3 | NotificationwinNetMapFullCrit | current | Windows ID map range is full. Authentication may fail. | |
| 1.3.6.1.4.1.12124.250.17.5 | NodewinNetAuth | |||
| 1.3.6.1.4.1.12124.250.17.5.3 | NotificationwinNetAuthCrit | current | Active Directory connectivity failure | |
| 1.3.6.1.4.1.12124.250.17.5.5 | NotificationwinNetAuthWarn | current | Active Directory connectivity issue | |
| 1.3.6.1.4.1.12124.250.17.6 | NodelwioParam | |||
| 1.3.6.1.4.1.12124.250.17.6.3 | NotificationlwioParamCrit | current | LWIO Parameter Invalid | |
| 1.3.6.1.4.1.12124.250.17.7 | NodewinSmbUpgrade | |||
| 1.3.6.1.4.1.12124.250.17.7.2 | NotificationwinSmbUpgradeWarn | current | Windows networking | |
| 1.3.6.1.4.1.12124.250.17.7.3 | NotificationwinSmbUpgradeCrit | current | Windows networking | |
| 1.3.6.1.4.1.12124.250.17.20 | NodewinNetworkCoalesce | |||
| 1.3.6.1.4.1.12124.250.17.20.3 | NotificationwinNetworkCoalesceCrit | current | There are problems with Windows networking components | |
| 1.3.6.1.4.1.12124.250.17.20.5 | NotificationwinNetworkCoalesceWarn | current | There are problems with Windows networking components | |
| 1.3.6.1.4.1.12124.250.17.21 | NodewinIDmapCoalesce | |||
| 1.3.6.1.4.1.12124.250.17.21.3 | NotificationwinIDmapCoalesceCrit | current | There are problems with the Windows ID map | |
| 1.3.6.1.4.1.12124.250.17.21.5 | NotificationwinIDmapCoalesceWarn | current | There are problems with the Windows ID map | |
| 1.3.6.1.4.1.12124.250.17.22 | NodewinAuthCoalesce | |||
| 1.3.6.1.4.1.12124.250.17.22.3 | NotificationwinAuthCoalesceCrit | current | There are problems with Windows authentication components | |
| 1.3.6.1.4.1.12124.250.17.22.5 | NotificationwinAuthCoalesceWarn | current | There are problems with Windows authentication components | |
| 1.3.6.1.4.1.12124.250.17.23 | NodewinAuthUpgrade | |||
| 1.3.6.1.4.1.12124.250.17.23.3 | NotificationwinAuthUpgradeCrit | current | There are problems with upgrading authentication components | |
| 1.3.6.1.4.1.12124.250.18 | NodenetworkingTraps | |||
| 1.3.6.1.4.1.12124.250.18.1 | NodenetStatus | |||
| 1.3.6.1.4.1.12124.250.18.1.3 | NotificationnetStatusCrit | current | A network interface is down | |
| 1.3.6.1.4.1.12124.250.18.1.5 | NotificationnetStatusWarn | current | A network interface is degraded or down | |
| 1.3.6.1.4.1.12124.250.18.20 | NodenetStatusCoalescing | |||
| 1.3.6.1.4.1.12124.250.18.20.3 | NotificationnetStatusCoalescingCrit | current | Critical network problems are occurring | |
| 1.3.6.1.4.1.12124.250.18.20.5 | NotificationnetStatusCoalescingWarn | current | Warning network problems are occurring | |
| 1.3.6.1.4.1.12124.250.19 | NodehardwareTraps | |||
| 1.3.6.1.4.1.12124.250.19.1 | NodehardwareError | |||
| 1.3.6.1.4.1.12124.250.19.1.1 | NodehardwareErrorMsg | |||
| 1.3.6.1.4.1.12124.250.19.1.1.3 | NotificationhardwareErrorMsgCrit | current | There is a message concerning a hardware faliure | |
| 1.3.6.1.4.1.12124.250.19.1.1.5 | NotificationhardwareErrorMsgWarn | current | There is a message concerning a potential hardware faliure | |
| 1.3.6.1.4.1.12124.250.19.1.3 | NotificationhardwareErrorCrit | current | A critical hardware error has occurred. | |
| 1.3.6.1.4.1.12124.250.19.1.5 | NotificationhardwareErrorWarn | current | A node has a hardware error | |
| 1.3.6.1.4.1.12124.250.19.1.7 | NotificationhardwareErrorInfo | current | A hardware problem is occurring. | |
| 1.3.6.1.4.1.12124.250.19.2 | NodehwError | |||
| 1.3.6.1.4.1.12124.250.19.2.3 | NotificationhwErrorCrit | current | Power Supply AC Failiure. | |
| 1.3.6.1.4.1.12124.250.19.10 | NodediskNodeOffline | |||
| 1.3.6.1.4.1.12124.250.19.10.3 | NotificationdiskNodeOfflineCrit | current | The expander is offline | |
| 1.3.6.1.4.1.12124.250.19.20 | NodehardwareCoalesced | |||
| 1.3.6.1.4.1.12124.250.19.20.1 | NotificationhardwareCoalescedEmerg | current | There are hardware issues on a node | |
| 1.3.6.1.4.1.12124.250.19.20.3 | NotificationhardwareCoalescedCrit | current | There are hardware issues on a node | |
| 1.3.6.1.4.1.12124.250.19.20.5 | NotificationhardwareCoalescedWarn | current | There are hardware issues on a node | |
| 1.3.6.1.4.1.12124.250.19.50 | NodesensorCoalesced | |||
| 1.3.6.1.4.1.12124.250.19.50.1 | NotificationsensorCoalescedEmerg | current | There are sensor issues on a node | |
| 1.3.6.1.4.1.12124.250.19.50.3 | NotificationsensorCoalescedCrit | current | There are sensor issues on a node | |
| 1.3.6.1.4.1.12124.250.19.50.5 | NotificationsensorCoalescedWarn | current | There are sensor issues on a node | |
| 1.3.6.1.4.1.12124.250.19.51 | NodefanCoalesced | |||
| 1.3.6.1.4.1.12124.250.19.51.1 | NotificationfanCoalescedEmerg | current | There are fan issues on a node | |
| 1.3.6.1.4.1.12124.250.19.51.3 | NotificationfanCoalescedCrit | current | There are fan issues on a node | |
| 1.3.6.1.4.1.12124.250.19.51.5 | NotificationfanCoalescedWarn | current | There are fan issues on a node | |
| 1.3.6.1.4.1.12124.250.19.52 | NodetempCoalesced | |||
| 1.3.6.1.4.1.12124.250.19.52.1 | NotificationtempCoalescedEmerg | current | There are temp issues on a node | |
| 1.3.6.1.4.1.12124.250.19.52.3 | NotificationtempCoalescedCrit | current | There are temp issues on a node | |
| 1.3.6.1.4.1.12124.250.19.52.5 | NotificationtempCoalescedWarn | current | There are temp issues on a node | |
| 1.3.6.1.4.1.12124.250.19.53 | NodevoltsCoalesced | |||
| 1.3.6.1.4.1.12124.250.19.53.1 | NotificationvoltsCoalescedEmerg | current | There are voltage issues on a node | |
| 1.3.6.1.4.1.12124.250.19.53.3 | NotificationvoltsCoalescedCrit | current | There are voltage issues on a node | |
| 1.3.6.1.4.1.12124.250.19.53.5 | NotificationvoltsCoalescedWarn | current | There are voltage issues on a node | |
| 1.3.6.1.4.1.12124.250.20 | NodesystemDiskTraps | |||
| 1.3.6.1.4.1.12124.250.20.1 | NodedriveStatus | |||
| 1.3.6.1.4.1.12124.250.20.1.1 | NotificationdriveStatusInfo | current | A node has detected a problem with a drive | |
| 1.3.6.1.4.1.12124.250.20.1.3 | NotificationdriveStatusCrit | current | A node has detected a problem with a drive | |
| 1.3.6.1.4.1.12124.250.20.1.5 | NotificationdriveStatusWarn | current | A node has detected a problem with a drive | |
| 1.3.6.1.4.1.12124.250.20.2 | NodebootDiskFail | |||
| 1.3.6.1.4.1.12124.250.20.2.3 | NotificationbootDiskFailCrit | current | Unhealthy boot disks, mirror is degraded. | |
| 1.3.6.1.4.1.12124.250.20.2.5 | NotificationbootDiskFailWarn | current | Unhealthy boot disks, mirror is degraded. | |
| 1.3.6.1.4.1.12124.250.20.3 | NodediskError | |||
| 1.3.6.1.4.1.12124.250.20.3.3 | NotificationdiskErrorWarn | current | A node's disks are having problems | |
| 1.3.6.1.4.1.12124.250.20.4 | NodebootDiskMirrorReqMissing | |||
| 1.3.6.1.4.1.12124.250.20.4.3 | NotificationbootdiskMirrorReqMissingCrit | current | Error creating mirror on bootdisks. | |
| 1.3.6.1.4.1.12124.250.20.20 | NodediskErrorCoalesced | |||
| 1.3.6.1.4.1.12124.250.20.20.3 | NotificationdiskErrorCoalescedCrit | current | A node's disks are having critical problems | |
| 1.3.6.1.4.1.12124.250.20.20.5 | NotificationdiskErrorCoalescedWarn | current | A node's disks are having warning level problems | |
| 1.3.6.1.4.1.12124.250.21 | NodesensorTraps | |||
| 1.3.6.1.4.1.12124.250.21.1 | NodehwPwrSupply | |||
| 1.3.6.1.4.1.12124.250.21.1.1 | NodehwPwrSupplyOver | |||
| 1.3.6.1.4.1.12124.250.21.1.1.3 | NotificationhwPwrSupplyOverCrit | current | Power supply current over critical threshold | |
| 1.3.6.1.4.1.12124.250.21.1.1.5 | NotificationhwPwrSupplyOverWarn | current | Power supply current over warning threshold | |
| 1.3.6.1.4.1.12124.250.21.1.2 | NodehwPwrSupplyUnder | |||
| 1.3.6.1.4.1.12124.250.21.1.2.3 | NotificationhwPwrSupplyUnderCrit | current | Power supply current under critical threshold | |
| 1.3.6.1.4.1.12124.250.21.1.2.5 | NotificationhwPwrSupplyUnderWarn | current | Power supply current under warning threshold | |
| 1.3.6.1.4.1.12124.250.21.2 | NodehwFan | |||
| 1.3.6.1.4.1.12124.250.21.2.1 | NodehwFanOver | |||
| 1.3.6.1.4.1.12124.250.21.2.1.3 | NotificationhwFanOverCrit | current | A node's fan is over critical threshold | |
| 1.3.6.1.4.1.12124.250.21.2.1.5 | NotificationhwFanOverWarn | current | A node's fan is over warning threshold | |
| 1.3.6.1.4.1.12124.250.21.2.1.7 | NotificationhwFanOverInfo | current | A node's fan is over warning threshold | |
| 1.3.6.1.4.1.12124.250.21.2.2 | NodehwFanUnder | |||
| 1.3.6.1.4.1.12124.250.21.2.2.3 | NotificationhwFanUnderCrit | current | A node's fan is under critical threshold | |
| 1.3.6.1.4.1.12124.250.21.2.2.5 | NotificationhwFanUnderWarn | current | A node's fan is under warning threshold | |
| 1.3.6.1.4.1.12124.250.21.2.2.7 | NotificationhwFanUnderInfo | current | A node's fan is under warning threshold | |
| 1.3.6.1.4.1.12124.250.21.2.3 | NotificationhwFanCrit | current | A node's fan failed | |
| 1.3.6.1.4.1.12124.250.21.2.5 | NotificationhwFanWarn | current | A node's fan monitor is about to fail | |
| 1.3.6.1.4.1.12124.250.21.10 | NodehwVoltage | |||
| 1.3.6.1.4.1.12124.250.21.10.1 | NodehwVoltageOver | |||
| 1.3.6.1.4.1.12124.250.21.10.1.3 | NotificationhwVoltageOverCrit | current | A node's voltage is over critical threshold | |
| 1.3.6.1.4.1.12124.250.21.10.1.5 | NotificationhwVoltageOverWarn | current | A node's voltage is over warning threshold | |
| 1.3.6.1.4.1.12124.250.21.10.1.7 | NotificationhwVoltageOverInfo | current | A node's voltage is over a threshold | |
| 1.3.6.1.4.1.12124.250.21.10.2 | NodehwVoltageUnder | |||
| 1.3.6.1.4.1.12124.250.21.10.2.3 | NotificationhwVoltageUnderCrit | current | A node's voltage is under critical threshold | |
| 1.3.6.1.4.1.12124.250.21.10.2.5 | NotificationhwVoltageUnderWarn | current | A node's voltage is under warning threshold | |
| 1.3.6.1.4.1.12124.250.21.10.2.7 | NotificationhwVoltageUnderInfo | current | A node's voltage is under a threshold | |
| 1.3.6.1.4.1.12124.250.21.11 | NodehwTemp | |||
| 1.3.6.1.4.1.12124.250.21.11.1 | NodehwTempOver | |||
| 1.3.6.1.4.1.12124.250.21.11.1.1 | NotificationhwTempOverEmerg | current | A node's temperature is over emergency threshold | |
| 1.3.6.1.4.1.12124.250.21.11.1.3 | NotificationhwTempOverCrit | current | A node's temperature is over critical threshold | |
| 1.3.6.1.4.1.12124.250.21.11.1.5 | NotificationhwTempOverWarn | current | A node's temperature is over warning threshold | |
| 1.3.6.1.4.1.12124.250.21.11.1.7 | NotificationhwTempOverInfo | current | A node's temperature is over a threshold | |
| 1.3.6.1.4.1.12124.250.21.11.2 | NodehwTempUnder | |||
| 1.3.6.1.4.1.12124.250.21.11.2.1 | NotificationhwTempUnderEmerg | current | A node's temperature is under emergency threshold | |
| 1.3.6.1.4.1.12124.250.21.11.2.3 | NotificationhwTempUnderCrit | current | A node's temperature is under critical threshold | |
| 1.3.6.1.4.1.12124.250.21.11.2.5 | NotificationhwTempUnderWarn | current | A node's temperature is under warning threshold | |
| 1.3.6.1.4.1.12124.250.21.11.2.7 | NotificationhwTempUnderInfo | current | A node's temperature is under a threshold | |
| 1.3.6.1.4.1.12124.250.21.12 | NodehwPower | |||
| 1.3.6.1.4.1.12124.250.21.12.3 | NotificationhwPowerCrit | current | A node has a power supply problem | |
| 1.3.6.1.4.1.12124.250.21.12.5 | NotificationhwPowerWarn | current | A node has a power supply monitoring problem | |
| 1.3.6.1.4.1.12124.250.21.13 | NodehwMem | |||
| 1.3.6.1.4.1.12124.250.21.13.3 | NotificationhwMemCrit | current | A node is low on memory | |
| 1.3.6.1.4.1.12124.250.21.14 | NodehwCpuThrottle | |||
| 1.3.6.1.4.1.12124.250.21.14.3 | NotificationhwCpuThrottleCrit | current | A node is at 100% CPU utilization | |
| 1.3.6.1.4.1.12124.250.21.15 | NodesensorMonitor | |||
| 1.3.6.1.4.1.12124.250.21.15.1 | NotificationsensorMonitorCrit | current | A sensor failed | |
| 1.3.6.1.4.1.12124.250.21.15.2 | NotificationsensorMonitorWarn | current | A sensor is failing | |
| 1.3.6.1.4.1.12124.250.21.16 | NodehwCurrent | |||
| 1.3.6.1.4.1.12124.250.21.16.1 | NodehwCurrentOver | |||
| 1.3.6.1.4.1.12124.250.21.16.1.1 | NotificationhwCurrentOverEmerg | current | A node's current is over emergency threshold | |
| 1.3.6.1.4.1.12124.250.21.16.1.3 | NotificationhwCurrentOverCrit | current | A node's current is over critical threshold | |
| 1.3.6.1.4.1.12124.250.21.16.1.5 | NotificationhwCurrentOverWarn | current | A node's current is over warning threshold | |
| 1.3.6.1.4.1.12124.250.21.16.1.7 | NotificationhwCurrentOverInfo | current | A node's current is over a threshold | |
| 1.3.6.1.4.1.12124.250.21.16.2 | NodehwCurrentUnder | |||
| 1.3.6.1.4.1.12124.250.21.16.2.1 | NotificationhwCurrentUnderEmerg | current | A node's current is under emergency threshold | |
| 1.3.6.1.4.1.12124.250.21.16.2.3 | NotificationhwCurrentUnderCrit | current | A node's current is under critical threshold | |
| 1.3.6.1.4.1.12124.250.21.16.2.5 | NotificationhwCurrentUnderWarn | current | A node's current is under warning threshold | |
| 1.3.6.1.4.1.12124.250.21.16.2.7 | NotificationhwCurrentUnderInfo | current | A node's current is under a threshold | |
| 1.3.6.1.4.1.12124.250.22 | NodestorageTransportTraps | |||
| 1.3.6.1.4.1.12124.250.22.1 | NodesasPhyError | |||
| 1.3.6.1.4.1.12124.250.22.1.5 | NotificationsasPhyErrorExpanderWarn | current | A SAS PHY error was detected in the expander. | |
| 1.3.6.1.4.1.12124.250.22.1.7 | NotificationsasPhyErrorControllerWarn | current | A SAS PHY error was detected in the controller. | |
| 1.3.6.1.4.1.12124.250.22.2 | NodestorageTransportCoalesced | |||
| 1.3.6.1.4.1.12124.250.22.2.1 | NotificationstorageTransportCoalescedEmerg | current | There are storage transport issues on a node | |
| 1.3.6.1.4.1.12124.250.22.2.3 | NotificationstorageCoalescedCrit | current | There are storage transport issues on a node | |
| 1.3.6.1.4.1.12124.250.22.2.5 | NotificationstorageCoalescedWarn | current | There are storage transport issues on a node | |
| 1.3.6.1.4.1.12124.250.23 | NodecloudPoolsTraps | |||
| 1.3.6.1.4.1.12124.250.23.1 | NodecloudpoolNetworkError | |||
| 1.3.6.1.4.1.12124.250.23.1.3 | NotificationcloudpoolNetworkErrorCrit | current | CloudPools network issues | |
| 1.3.6.1.4.1.12124.250.23.2 | NodecloudpoolAuthenticationError | |||
| 1.3.6.1.4.1.12124.250.23.2.3 | NotificationcloudpoolAuthenticationErrorCrit | current | CloudPools authentication issues | |
| 1.3.6.1.4.1.12124.250.23.3 | NodecloudpoolAuthorizationError | |||
| 1.3.6.1.4.1.12124.250.23.3.3 | NotificationcloudpoolAuthorizationErrorCrit | current | CloudPools authorization issues | |
| 1.3.6.1.4.1.12124.250.23.4 | NodecloudpoolBucketNotFoundError | |||
| 1.3.6.1.4.1.12124.250.23.4.3 | NotificationcloudpoolBucketNotFoundErrorCrit | current | CloudPools bucket not found issues | |
| 1.3.6.1.4.1.12124.250.23.5 | NodecloudpoolObjectNotFoundError | |||
| 1.3.6.1.4.1.12124.250.23.5.3 | NotificationcloudpoolObjectNotFoundErrorCrit | current | CloudPools Object not found issues | |
| 1.3.6.1.4.1.12124.250.23.6 | NodecloudpoolDataCorruptionIntegrityError | |||
| 1.3.6.1.4.1.12124.250.23.6.1 | NotificationcloudpoolDataCorruptionIntegrityErrorEmerg | current | CloudPools data corruption integrity emergency issues | |
| 1.3.6.1.4.1.12124.250.23.7 | NodecloudpoolNoUsableAccountFoundError | |||
| 1.3.6.1.4.1.12124.250.23.7.3 | NotificationcloudpoolNoUsableAccountFoundErrorCrit | current | CloudPools no usable account found for the policy, cloudpool | |
| 1.3.6.1.4.1.12124.250.23.8 | NodecloudpoolCertificateError | |||
| 1.3.6.1.4.1.12124.250.23.8.3 | NotificationcloudpoolCertificateErrorCrit | current | CloudPools Certificate issues | |
| 1.3.6.1.4.1.12124.250.24 | NodeupgradeTraps | |||
| 1.3.6.1.4.1.12124.250.24.1 | NodeupgradeStart | |||
| 1.3.6.1.4.1.12124.250.24.1.7 | NotificationupgradeStartInfo | current | An upgrade or rollback has been started. | |
| 1.3.6.1.4.1.12124.250.24.2 | NodeupgradeFinish | |||
| 1.3.6.1.4.1.12124.250.24.2.7 | NotificationupgradeFinishInfo | current | An upgrade or rollback has finished. | |
| 1.3.6.1.4.1.12124.250.24.3 | NodeupgradeClusterEvent | |||
| 1.3.6.1.4.1.12124.250.24.3.3 | NotificationupgradeClusterEventCrit | current | Upgrade cluster event. | |
| 1.3.6.1.4.1.12124.250.24.3.5 | NotificationupgradeClusterEventWarn | current | Upgrade cluster event. | |
| 1.3.6.1.4.1.12124.250.24.3.7 | NotificationupgradeClusterEventInfo | current | Upgrade cluster event. | |
| 1.3.6.1.4.1.12124.250.24.4 | NodeupgradeNodeEvent | |||
| 1.3.6.1.4.1.12124.250.24.4.3 | NotificationupgradeNodeEventCrit | current | Upgrade node event. | |
| 1.3.6.1.4.1.12124.250.24.4.5 | NotificationupgradeNodeEventWarn | current | Upgrade node event. | |
| 1.3.6.1.4.1.12124.250.24.4.7 | NotificationupgradeNodeEventInfo | current | Upgrade node event. | |
| 1.3.6.1.4.1.12124.250.24.5 | NodeupgradeRollbackStart | |||
| 1.3.6.1.4.1.12124.250.24.5.7 | NotificationupgradeRollbackStartInfo | current | Upgrade rollback start. | |
| 1.3.6.1.4.1.12124.250.50 | Nodevariables | |||
| 1.3.6.1.4.1.12124.250.50.1 | ScalarnodeIdentifier | accessible-for-notify | current | The Logical Node Number of the node referenced in the notification. |
| 1.3.6.1.4.1.12124.250.50.2 | ScalarmeasuredValue | accessible-for-notify | current | The measured value that triggered the event |
| 1.3.6.1.4.1.12124.250.50.3 | Scalarunits | accessible-for-notify | current | The units of the measurement |
| 1.3.6.1.4.1.12124.250.50.4 | Scalaroid | accessible-for-notify | current | The OID of the sensor reporting a problem |
| 1.3.6.1.4.1.12124.250.50.5 | Scalarbay | accessible-for-notify | current | Drive bay number |
| 1.3.6.1.4.1.12124.250.50.6 | ScalarifName | accessible-for-notify | current | Interface name |
| 1.3.6.1.4.1.12124.250.50.7 | Scalarphy | accessible-for-notify | current | PHY connection |
| 1.3.6.1.4.1.12124.250.50.8 | ScalarerrorMessage | accessible-for-notify | current | Error message |
| 1.3.6.1.4.1.12124.250.50.9 | Scalarerrno | accessible-for-notify | current | Error number |
| 1.3.6.1.4.1.12124.250.50.10 | ScalarstringArg | accessible-for-notify | current | A trap-related string argument. |
| 1.3.6.1.4.1.12124.250.50.11 | Scalarmessage | accessible-for-notify | current | A trap-related message string. |
| 1.3.6.1.4.1.12124.250.50.12 | Scalari64Arg | accessible-for-notify | current | Error number |
| 1.3.6.1.4.1.12124.250.50.13 | Scalari32Arg | accessible-for-notify | current | Integer argument |
| 1.3.6.1.4.1.12124.250.50.14 | ScalarmeasuredValueStr | accessible-for-notify | current | The measured value that triggered the event represented as string |
| 1.3.6.1.4.1.12124.250.50.15 | ScalarinstanceIdentifier | accessible-for-notify | current | Instance ID of event generating the trap |
| 1.3.6.1.4.1.12124.250.50.16 | ScalardeviceIdentifier | accessible-for-notify | current | The Device Node Number of the node referenced in the notification. |
| 1.3.6.1.4.1.12124.250.51 | NodetrapConformance | |||
| 1.3.6.1.4.1.12124.250.51.1 | GroupgroupStateTrapsGroup | current | Collection of traps for group state. | |
| 1.3.6.1.4.1.12124.250.51.11 | GroupfilesystemTrapsGroup | current | Collection of filesystem traps. | |
| 1.3.6.1.4.1.12124.250.51.12 | GroupsmartQuotaTrapsGroup | current | Collection of smartQuota traps. | |
| 1.3.6.1.4.1.12124.250.51.13 | GroupsnapshotTrapsGroup | current | Collection of snapshot traps. | |
| 1.3.6.1.4.1.12124.250.51.14 | GroupsyncIQTrapsGroup | current | Collection of syncIQ traps. | |
| 1.3.6.1.4.1.12124.250.51.15 | GroupsoftwareTrapsGroup | current | Collection of software traps. | |
| 1.3.6.1.4.1.12124.250.51.16 | GroupavscanTrapsGroup | current | Collection of avscan traps. | |
| 1.3.6.1.4.1.12124.250.51.17 | GroupnetProtoTrapsGroup | current | Collection of net protocol traps. | |
| 1.3.6.1.4.1.12124.250.51.18 | GroupnetworkingTrapsGroup | current | Collection of networking traps. | |
| 1.3.6.1.4.1.12124.250.51.19 | GrouphardwareTrapsGroup | current | Collection of sensor traps. | |
| 1.3.6.1.4.1.12124.250.51.20 | GroupsystemDiskTrapsGroup | current | Collection of system disk traps. | |
| 1.3.6.1.4.1.12124.250.51.21 | GroupsensorTrapsGroup | current | Collection of sensor traps. | |
| 1.3.6.1.4.1.12124.250.51.22 | GroupstorageTransportTrapsGroup | current | Collection of storage transport traps. | |
| 1.3.6.1.4.1.12124.250.51.23 | GroupcloudPoolsTrapsGroup | current | Collection of cloud pools traps. | |
| 1.3.6.1.4.1.12124.250.51.24 | GroupupgradeTrapsGroup | current | Collection of upgrade traps. | |
| 1.3.6.1.4.1.12124.250.51.50 | GroupvariablesGroup | current | Collection of variable traps. | |
| 1.3.6.1.4.1.12124.250.52 | NodetrapCompliance | |||
| 1.3.6.1.4.1.12124.250.52.1 | CompliancetrapGroupCompliance | current | Compliance statement for the Isilon traps. |