MIB Viewer

JMA-WIRELESS-SPV-4-MIB

2242 objects
This MIB module defines objects for monitoring and managing DAS systems 1.0 of JMA Wireless.
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDateAndTime MacAddress TEXTUAL-CONVENTION TimeInterval
OIDNameAccessStatusDescription
1.3.6.1.4.1.6626NodejmaWireless
1.3.6.1.4.1.6626.6000NodejmaWirelessTelecomunication
1.3.6.1.4.1.6626.6000.4Identityspv-4This MIB module defines objects for monitoring and managing DAS systems 1.0 of JMA Wireless.
1.3.6.1.4.1.6626.6000.4.1NodespvGlobals
1.3.6.1.4.1.6626.6000.4.1.1ScalarspvStationNameread-writecurrentName of the system
1.3.6.1.4.1.6626.6000.4.1.2ScalarspvStationDescriptionread-writecurrentdescription of the system
1.3.6.1.4.1.6626.6000.4.1.3ScalarspvStationLocationLatituderead-writecurrentLatitude of the system
1.3.6.1.4.1.6626.6000.4.1.4ScalarspvStationLocationLongituderead-writecurrentLongitude of the system
1.3.6.1.4.1.6626.6000.4.1.5ScalarspvProductionDateread-onlycurrentproduction date of the management module.
1.3.6.1.4.1.6626.6000.4.1.6ScalarspvCommissionDateread-writecurrentcommissioning date of the management module.
1.3.6.1.4.1.6626.6000.4.1.7ScalarspvActualDateread-writecurrentcurrent date of the system
1.3.6.1.4.1.6626.6000.4.1.8ScalarspvTimezoneread-writecurrenttimezone of the system in the format +-xxHyyM where xx are the hours: 00,01,02... and yy are the minutes: 00,15,30,45
1.3.6.1.4.1.6626.6000.4.1.9NodespvHeartbeat
1.3.6.1.4.1.6626.6000.4.1.9.1ScalarspvHeartbeatIntervalread-writecurrenttime interval expressed in hours after which the system send and heartbeat to the operators enabled to receive it
1.3.6.1.4.1.6626.6000.4.1.9.2ScalarspvHeartbeatTimeread-onlycurrenthearbeat time
1.3.6.1.4.1.6626.6000.4.1.10NodespvRelease
1.3.6.1.4.1.6626.6000.4.1.10.1TablespvReleaseTablenot-accessiblecurrentcontains the version of kernel, ramdisk and web pages
1.3.6.1.4.1.6626.6000.4.1.10.1.1RowspvReleaseEntrynot-accessiblecurrentDescription.
1.3.6.1.4.1.6626.6000.4.1.10.1.1.1ColumnspvReleaseIndexnot-accessiblecurrentrelease element index
1.3.6.1.4.1.6626.6000.4.1.10.1.1.2ColumnspvReleaseNameread-onlycurrentrelease element name
1.3.6.1.4.1.6626.6000.4.1.10.1.1.3ColumnspvReleaseVersionread-onlycurrentrelease element version
1.3.6.1.4.1.6626.6000.4.1.10.1.1.4ColumnspvReleaseBuildread-onlycurrentrelease element build date
1.3.6.1.4.1.6626.6000.4.1.11NodespvAssistance
1.3.6.1.4.1.6626.6000.4.1.11.1TablespvAssistanceTablenot-accessiblecurrentassistance data: name, address, mail, telephones
1.3.6.1.4.1.6626.6000.4.1.11.1.1RowspvAssistanceEntrynot-accessiblecurrentDescription.
1.3.6.1.4.1.6626.6000.4.1.11.1.1.1ColumnspvAssistanceIndexnot-accessiblecurrentrelease element index
1.3.6.1.4.1.6626.6000.4.1.11.1.1.2ColumnspvAssistanceLabelread-onlycurrentrelease element name
1.3.6.1.4.1.6626.6000.4.1.11.1.1.3ColumnspvAssistanceValueread-onlycurrentrelease element name
1.3.6.1.4.1.6626.6000.4.1.11.2ScalarspvAssistanceShowExtraParamsread-writecurrentShow extra parameters (Eg: RF Uplink Power).
1.3.6.1.4.1.6626.6000.4.1.12NodespvCompany
1.3.6.1.4.1.6626.6000.4.1.12.1ScalarspvCompanyNameread-writecurrentCompany name, who sells the product
1.3.6.1.4.1.6626.6000.4.1.13ScalarspvAtmegaBaudrateread-onlycurrentATMega Baudrate
1.3.6.1.4.1.6626.6000.4.1.14NodespvCommands
1.3.6.1.4.1.6626.6000.4.1.14.1ScalarspvRestartBoardread-writecurrentRestart Board: 1 for O.S, 2 for JMA Wireless processes only
1.3.6.1.4.1.6626.6000.4.1.14.2ScalarspvUpgradeActionread-writecurrentcommands and states of upgrade/backup procedure
1.3.6.1.4.1.6626.6000.4.1.14.3ScalarspvUpgradeConfigFileUrlread-writecurrentURL of the configuration file to download, or the address of the prepared config file.
1.3.6.1.4.1.6626.6000.4.1.14.4ScalarspvUpgradeFirmwareFileUrlread-writecurrentURL of the firmware file to download.
1.3.6.1.4.1.6626.6000.4.1.14.5ScalarspvUpgradeProgressread-onlycurrentProgress percentage of the current actions (as specified in spvUpgradeAction).
1.3.6.1.4.1.6626.6000.4.1.14.6ScalarspvUpgradeModuleConfigUrlread-writecurrentURL of the module config file (.bin) to download.
1.3.6.1.4.1.6626.6000.4.1.14.7ScalarspvResyncAlarmsread-writecurrentResync alarms: 1 for active alarms, 2 for all alarms
1.3.6.1.4.1.6626.6000.4.1.15ScalarspvDiscoveryStateread-writecurrentvar used to set discovery commands and to read discovery esit.
1.3.6.1.4.1.6626.6000.4.1.16NodespvInventoryParameters
1.3.6.1.4.1.6626.6000.4.1.16.1TablespvInventoryDateTablenot-accessiblecurrentTable containing the data for inventories.
1.3.6.1.4.1.6626.6000.4.1.16.1.1RowspvInventoryDateEntrynot-accessiblecurrentDescription.
1.3.6.1.4.1.6626.6000.4.1.16.1.1.1ColumnspvInventoryDateIndexnot-accessiblecurrentrelease element index
1.3.6.1.4.1.6626.6000.4.1.16.1.1.2ColumnspvInventoryDateNameread-onlycurrentrelease element name
1.3.6.1.4.1.6626.6000.4.1.16.1.1.3ColumnspvInventoryDateDeleteread-onlycurrentif 1 delete the current value
1.3.6.1.4.1.6626.6000.4.1.16.2ScalarspvInventoryStateread-writecurrentvar used to launch inventory
1.3.6.1.4.1.6626.6000.4.1.16.3ScalarspvInventoryDateSelectedItemread-onlycurrentInventory selected date format: YYYmmDDHHmm
1.3.6.1.4.1.6626.6000.4.1.16.4ScalarspvInventoryDateSelectedIndexread-writecurrentvar used to launch inventory
1.3.6.1.4.1.6626.6000.4.1.16.5ScalarspvInventoryProgressread-onlycurrentinventory progress in percentage
1.3.6.1.4.1.6626.6000.4.1.17NodespvUser
1.3.6.1.4.1.6626.6000.4.1.17.1TablespvUserTablenot-accessiblecurrentauthentication table
1.3.6.1.4.1.6626.6000.4.1.17.1.1RowspvUserEntrynot-accessiblecurrentauthentication table entry
1.3.6.1.4.1.6626.6000.4.1.17.1.1.1ColumnspvUserIndexnot-accessiblecurrentIndex for users table
1.3.6.1.4.1.6626.6000.4.1.17.1.1.2ColumnspvUserNameread-onlycurrentUsername registered for accessing functionalities
1.3.6.1.4.1.6626.6000.4.1.17.1.1.3ColumnspvUserRoleread-writecurrentgroup: admins, superusers, users, guests
1.3.6.1.4.1.6626.6000.4.1.17.1.1.4ColumnspvUserAuthPasswordread-onlycurrentAuthorization password of the username. This password is used for accessing web interface and as SNMPv3 authorization password.
1.3.6.1.4.1.6626.6000.4.1.17.1.1.5ColumnspvUserAuthPasswordLastUpdateread-onlycurrentLast modification date of the privacy password.
1.3.6.1.4.1.6626.6000.4.1.17.1.1.6ColumnspvUserPrivacyPasswordread-onlycurrentPrivacy password of the username. This password is used only by SNMPv3 protocol for encrypting data between client and server.
1.3.6.1.4.1.6626.6000.4.1.17.1.1.7ColumnspvUserPrivacyPasswordLastUpdateread-onlycurrentLast modification date of the authorization password.
1.3.6.1.4.1.6626.6000.4.1.17.2NodespvUserVars
1.3.6.1.4.1.6626.6000.4.1.17.2.1ScalarspvUserPasswordExpireEnableread-writecurrentIndex for users table
1.3.6.1.4.1.6626.6000.4.1.17.2.2ScalarspvUserPasswordExpireDaysread-writecurrentIndex for users table
1.3.6.1.4.1.6626.6000.4.1.18NodespvNetConfig
1.3.6.1.4.1.6626.6000.4.1.18.1NodespvWan
1.3.6.1.4.1.6626.6000.4.1.18.1.1ScalarspvWanIpAddressread-writecurrentSystem Net Configuration: Ip Address
1.3.6.1.4.1.6626.6000.4.1.18.1.2ScalarspvWanNetmaskread-writecurrentSystem Net Configuration: Netmask
1.3.6.1.4.1.6626.6000.4.1.18.1.3ScalarspvWanMacAddressread-onlycurrentSystem Net Configuration: MAC Address
1.3.6.1.4.1.6626.6000.4.1.18.1.4ScalarspvWanGatewayIpAddressread-writecurrentSystem Net Configuration: Gateway Ip Address
1.3.6.1.4.1.6626.6000.4.1.18.1.5ScalarspvWanNeedApplySettingsread-writecurrentSystem Net Configuration: Apply the network configuration 1 = ON ( Setting new Configuration )
1.3.6.1.4.1.6626.6000.4.1.18.1.6ScalarspvWanCommStateread-onlycurrentstate of the comm interface eth0
1.3.6.1.4.1.6626.6000.4.1.18.1.7ScalarspvWanMturead-writecurrentMax transmit unit for eth0 interface
1.3.6.1.4.1.6626.6000.4.1.18.1.8ScalarspvWanEnableFixedIpAddressread-writecurrentEnable fixed IP address 192.168.1.101
1.3.6.1.4.1.6626.6000.4.1.18.1.9ScalarspvWanIPVersionread-writecurrentThis is IP version to use for WAN communications.
1.3.6.1.4.1.6626.6000.4.1.18.1.10TablespvWanIPv6Tablenot-accessiblecurrentIPv6 address of the Wan interface
1.3.6.1.4.1.6626.6000.4.1.18.1.10.1RowspvWanIPv6Entrynot-accessiblecurrentAn entry representing an ipv6 address
1.3.6.1.4.1.6626.6000.4.1.18.1.10.1.1ColumnspvWanIPv6EntryIndexnot-accessiblecurrentThe address type of WAN address.
1.3.6.1.4.1.6626.6000.4.1.18.1.10.1.2ColumnspvWanIPv6GlobalLinkAddrread-writecurrentIPv6 Global ip address of WAN interface.
1.3.6.1.4.1.6626.6000.4.1.18.2NodespvVpn
1.3.6.1.4.1.6626.6000.4.1.18.2.1ScalarspvVpnEnableread-writecurrentenable/disable the OpenVPN interface
1.3.6.1.4.1.6626.6000.4.1.18.2.2ScalarspvVpnServerIpAddressread-writecurrentIP address of the OpenVPN server
1.3.6.1.4.1.6626.6000.4.1.18.2.3ScalarspvVpnRemotePortread-writecurrentremote port of the OpenVPN server
1.3.6.1.4.1.6626.6000.4.1.18.2.4ScalarspvVpnNeedApplySettingsread-writecurrentVPN Net Configuration: Apply the network configuration 1 = need to be set 0 = no changes to do
1.3.6.1.4.1.6626.6000.4.1.18.2.5ScalarspvVpnIpAddressread-onlycurrentipaddress on VPN network
1.3.6.1.4.1.6626.6000.4.1.18.2.6ScalarspvVpnNetmaskread-writecurrentnetmask on VPN network
1.3.6.1.4.1.6626.6000.4.1.18.2.7ScalarspvVpnMturead-writecurrentMax transmit unit for tap0 interface
1.3.6.1.4.1.6626.6000.4.1.18.2.8ScalarspvVpnCommStateread-onlycurrentstate of the comm interface tap0
1.3.6.1.4.1.6626.6000.4.1.18.2.9ScalarspvVpnCommDevread-writecurrent0 = tap or 1 = tun device
1.3.6.1.4.1.6626.6000.4.1.18.2.10ScalarspvVpnServerIpAddress6read-writecurrentIP V6 address of the OpenVPN server
1.3.6.1.4.1.6626.6000.4.1.18.2.11ScalarspvVpnIpAddress6read-onlycurrentIP V6 Address on VPN network
1.3.6.1.4.1.6626.6000.4.1.18.3NodespvServices
1.3.6.1.4.1.6626.6000.4.1.18.3.1ScalarspvTimeSynchronizationModeread-writecurrenttime synch mode
1.3.6.1.4.1.6626.6000.4.1.18.3.2ScalarspvFtpModeread-writecurrentftp mode
1.3.6.1.4.1.6626.6000.4.1.18.3.3ScalarspvShellModeread-writecurrentshell mode
1.3.6.1.4.1.6626.6000.4.1.18.3.4ScalarspvHttpModeread-writecurrentshell mode
1.3.6.1.4.1.6626.6000.4.1.18.3.5ScalarspvSnmpModeread-writecurrentsnmp get/set mode
1.3.6.1.4.1.6626.6000.4.1.18.3.6ScalarspvSnmpTrapModeread-writecurrentsnmp trap mode
1.3.6.1.4.1.6626.6000.4.1.18.3.7ScalarspvTunnelModeread-writecurrenttunnel without/with SSL encryption
1.3.6.1.4.1.6626.6000.4.1.18.4ScalarspvFirewallEnableread-writecurrentfirewall enabled / disabled
1.3.6.1.4.1.6626.6000.4.1.18.5ScalarspvServicesApplySettingsread-writecurrentapply settings for services
1.3.6.1.4.1.6626.6000.4.1.18.6NodespvPorts
1.3.6.1.4.1.6626.6000.4.1.18.6.1ScalarspvHttpPortread-writecurrentport for HTTP traffic
1.3.6.1.4.1.6626.6000.4.1.18.6.2ScalarspvHttpsPortread-writecurrentport for HTTPS traffic
1.3.6.1.4.1.6626.6000.4.1.18.6.3ScalarspvTunnelPortread-writecurrentTCP port for connecting via OMC
1.3.6.1.4.1.6626.6000.4.1.18.6.4ScalarspvSTunnelPortread-writecurrentport for Secure Tunnel traffic
1.3.6.1.4.1.6626.6000.4.1.18.6.5ScalarspvTelnetPortread-writecurrentport for Telnet
1.3.6.1.4.1.6626.6000.4.1.18.6.6ScalarspvSshPortread-writecurrentport for SSH
1.3.6.1.4.1.6626.6000.4.1.18.6.7ScalarspvFtpPortread-writecurrentport for FTP synchronization
1.3.6.1.4.1.6626.6000.4.1.18.6.8ScalarspvSftpPortread-writecurrentport for SFTP synchronization
1.3.6.1.4.1.6626.6000.4.1.18.7NodespvSynchronization
1.3.6.1.4.1.6626.6000.4.1.18.7.1ScalarspvTimeRefreshNowread-writecurrentforce synchromization now
1.3.6.1.4.1.6626.6000.4.1.18.7.2NodespvNtpServiceParameters
1.3.6.1.4.1.6626.6000.4.1.18.7.2.1ScalarspvNtpTimeRefreshread-writecurrenttime interval of refresh of the date and time from the NTP server
1.3.6.1.4.1.6626.6000.4.1.18.7.2.2ScalarspvNtpServerread-writecurrentIP Address of the NTP server
1.3.6.1.4.1.6626.6000.4.1.18.7.2.3ScalarspvNtpPortread-writecurrentport for NTP synchronization
1.3.6.1.4.1.6626.6000.4.1.18.7.2.4ScalarspvNtpServer6read-writecurrentIP V6 Address of the NTP server
1.3.6.1.4.1.6626.6000.4.1.18.7.3NodespvPtpServiceParameters
1.3.6.1.4.1.6626.6000.4.1.18.7.3.1ScalarspvPtpTimeRefreshread-writecurrenttime interval for synchromization
1.3.6.1.4.1.6626.6000.4.1.18.7.3.2ScalarspvPtpServerread-writecurrentIP Address of the PtoP server
1.3.6.1.4.1.6626.6000.4.1.18.7.3.3ScalarspvPtpPortread-writecurrentport for PtoP synchronization
1.3.6.1.4.1.6626.6000.4.1.18.7.3.4ScalarspvPtpPort2read-writecurrentport for PtoP synchronization
1.3.6.1.4.1.6626.6000.4.1.18.7.3.5ScalarspvPtpServer6read-writecurrentIP V6 Address of the PtoP server
1.3.6.1.4.1.6626.6000.4.1.18.8NodespvNotificationTrap
1.3.6.1.4.1.6626.6000.4.1.18.8.1ScalarspvNotificationTrapCountread-onlycurrentSystem Net Configuration: Numbers Manager for SNMP
1.3.6.1.4.1.6626.6000.4.1.18.8.2TablespvNotificationTrapTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.1.18.8.2.1RowspvNotificationTrapEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.1.18.8.2.1.1ColumnspvNotificationTrapIndexnot-accessiblecurrentManager IP address
1.3.6.1.4.1.6626.6000.4.1.18.8.2.1.2ColumnspvNotificationTrapIpAddressread-createcurrentSystem Net Configuration: Ip Address Manager for SNMP
1.3.6.1.4.1.6626.6000.4.1.18.8.2.1.3ColumnspvNotificationTrapPortread-createcurrentTrqp Manager port
1.3.6.1.4.1.6626.6000.4.1.18.8.2.1.4ColumnspvNotificationTrapAlarmSeverityread-createcurrentDescription
1.3.6.1.4.1.6626.6000.4.1.18.8.2.1.5ColumnspvNotificationTrapHeartbeatEnableread-createcurrentDescription
1.3.6.1.4.1.6626.6000.4.1.18.8.2.1.6ColumnspvNotificationTrapAlarmEnableread-createcurrentControl for creating and deleting entries in the manager table
1.3.6.1.4.1.6626.6000.4.1.18.8.2.1.7ColumnspvNotificationTrapUsernameread-createcurrentusername who sends trap to agent in snmpv3
1.3.6.1.4.1.6626.6000.4.1.18.8.2.1.8ColumnspvNotificationTrapIpAddress6read-createcurrentSystem Net Configuration: Ip V6 Address Manager for SNMP
1.3.6.1.4.1.6626.6000.4.1.18.9NodespvPing
1.3.6.1.4.1.6626.6000.4.1.18.9.1ScalarspvPingIntervalread-writecurrentping interval
1.3.6.1.4.1.6626.6000.4.1.18.9.2TablespvPingTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.1.18.9.2.1RowspvPingEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.1.18.9.2.1.1ColumnspvPingIndexnot-accessiblecurrentManager IP address
1.3.6.1.4.1.6626.6000.4.1.18.9.2.1.2ColumnspvPingIpAddressread-writecurrentaddress to ping
1.3.6.1.4.1.6626.6000.4.1.18.9.2.1.3ColumnspvPingInterfaceread-writecurrentnet interface on which to ping
1.3.6.1.4.1.6626.6000.4.1.18.9.2.1.4ColumnspvPingEnableread-writecurrentnet interface on which to ping
1.3.6.1.4.1.6626.6000.4.1.18.9.2.1.5ColumnspvPingIpAddress6read-writecurrentaddress to ping
1.3.6.1.4.1.6626.6000.4.1.18.10ScalarspvTunnelInactivityTimeoutread-writecurrentminutes timeout from o to 1 year
1.3.6.1.4.1.6626.6000.4.1.18.11NodespvLan
1.3.6.1.4.1.6626.6000.4.1.18.11.1ScalarspvLanIpAddressread-onlycurrentSystem Net Configuration: Eth1 Ip Address
1.3.6.1.4.1.6626.6000.4.1.18.11.2ScalarspvLanNetmaskread-onlycurrentSystem Net Configuration: Eth1 Netmask
1.3.6.1.4.1.6626.6000.4.1.18.11.3ScalarspvLanMacAddressread-onlycurrentSystem Net Configuration: Eth1 MAC Address
1.3.6.1.4.1.6626.6000.4.1.18.11.4ScalarspvLanGatewayIpAddressread-onlycurrentSystem Net Configuration: Eth1 Gateway Ip Address
1.3.6.1.4.1.6626.6000.4.1.18.11.5ScalarspvLanCommStateread-onlycurrentEth1 communication state
1.3.6.1.4.1.6626.6000.4.1.18.11.6ScalarspvLanMturead-onlycurrentEth1 Max transmit unit
1.3.6.1.4.1.6626.6000.4.1.18.11.7ScalarspvLanIpAddress6read-onlycurrentSystem Net Configuration: Eth1 Ip V6 Address
1.3.6.1.4.1.6626.6000.4.1.19NodespvModemConfig
1.3.6.1.4.1.6626.6000.4.1.19.1NodespvModemParameters
1.3.6.1.4.1.6626.6000.4.1.19.1.1ScalarspvModemSimNumberread-writecurrentSIM number of the modem inside the management module
1.3.6.1.4.1.6626.6000.4.1.19.1.2ScalarspvModemSmsCenterread-writecurrentSIM number of the SMS service center
1.3.6.1.4.1.6626.6000.4.1.19.1.3ScalarspvModemTyperead-onlycurrentmodem type
1.3.6.1.4.1.6626.6000.4.1.19.1.4ScalarspvModemRssiread-onlycurrentModem RSSI signal power
1.3.6.1.4.1.6626.6000.4.1.19.1.5ScalarspvModemBaudrateread-writecurrentmodem speed (bps)
1.3.6.1.4.1.6626.6000.4.1.19.1.6ScalarspvModemCommStateread-onlycurrentstate of the modem
1.3.6.1.4.1.6626.6000.4.1.19.1.7ScalarspvGprsEnableread-writecurrentallows to use the modem in gprs connection if = 1
1.3.6.1.4.1.6626.6000.4.1.19.1.8ScalarspvPppCommStateread-onlycurrentstate of the comm interface ppp0
1.3.6.1.4.1.6626.6000.4.1.19.1.9ScalarspvPppMturead-writecurrentMax transmit unit for ppp0 interface
1.3.6.1.4.1.6626.6000.4.1.19.1.10ScalarspvModemNeedApplySettingsread-writecurrentModem Configuration: Apply the new configuration 1 = need to be set 0 = no changes to do
1.3.6.1.4.1.6626.6000.4.1.19.1.11ScalarspvModemResetread-writecurrentvar used to reset modem
1.3.6.1.4.1.6626.6000.4.1.19.1.12ScalarspvPppBaudrateread-writecurrentmodem speed (bps)
1.3.6.1.4.1.6626.6000.4.1.19.1.13ScalarspvGsmmuxBaudrateread-writecurrentmodem speed (bps)
1.3.6.1.4.1.6626.6000.4.1.19.1.14ScalarspvModemModeread-writecurrentmode=0 MUX, 1=SMS only, 2=GPRS only
1.3.6.1.4.1.6626.6000.4.1.19.1.15ScalarspvModemType2g3gread-onlycurrentModem cell info
1.3.6.1.4.1.6626.6000.4.1.19.1.16ScalarspvModemChannelNumberread-onlycurrentModem cell info
1.3.6.1.4.1.6626.6000.4.1.19.1.17ScalarspvModemLacread-onlycurrentModem cell info
1.3.6.1.4.1.6626.6000.4.1.19.1.18ScalarspvModemCellIdread-onlycurrentModem cell info
1.3.6.1.4.1.6626.6000.4.1.19.1.19ScalarspvModem2gSignalStrengthread-onlycurrentModem cell info
1.3.6.1.4.1.6626.6000.4.1.19.1.20ScalarspvModem3gRscpread-onlycurrentModem cell info
1.3.6.1.4.1.6626.6000.4.1.19.1.21ScalarspvModem3gEcNoread-onlycurrentModem cell info
1.3.6.1.4.1.6626.6000.4.1.19.1.22ScalarspvModem3gPscread-onlycurrentModem cell info
1.3.6.1.4.1.6626.6000.4.1.19.1.23ScalarspvModemRadioBandread-writecurrentwhich band the modem should connect. ETM9910: 1 GSM900 2 GSM1800 3 GSM ALL 16 WCDMA 2100 128 WCDMA 900 144 WCDMA ALL 147 WCDMA and GSM ALL SimCom: 2 Automatic …
1.3.6.1.4.1.6626.6000.4.1.19.1.24ScalarspvPppIpAddressread-writecurrentipaddress on PPP network
1.3.6.1.4.1.6626.6000.4.1.19.1.25ScalarspvPppNetmaskread-writecurrentnetmask on PPP network
1.3.6.1.4.1.6626.6000.4.1.19.1.26NodespvModemUserCmd
1.3.6.1.4.1.6626.6000.4.1.19.1.26.1ScalarspvModemUserCmdStateread-writecurrentspvModemUserCmdState: start, in progress, result available
1.3.6.1.4.1.6626.6000.4.1.19.1.26.2ScalarspvModemUserCmdRequestread-writecurrentspvModemUserCmdRequest: AT Command for modem (no terminator)
1.3.6.1.4.1.6626.6000.4.1.19.1.26.3ScalarspvModemUserCmdAnswerread-onlycurrentspvModemUserCmdAnswer: AT Command answer
1.3.6.1.4.1.6626.6000.4.1.19.1.27ScalarspvIncomingCallEnableread-writecurrenttells if it's possible to accept calls
1.3.6.1.4.1.6626.6000.4.1.19.1.28ScalarspvModemEduUsbSupportread-onlycurrenttells if usb is supported by hardware
1.3.6.1.4.1.6626.6000.4.1.19.1.29ScalarspvModemRestartTimeoutread-onlycurrenttime in seconds for restart modem
1.3.6.1.4.1.6626.6000.4.1.19.1.30ScalarspvPppIpAddress6read-writecurrentipaddress V6 on PPP network
1.3.6.1.4.1.6626.6000.4.1.19.2NodespvNotificationSms
1.3.6.1.4.1.6626.6000.4.1.19.2.1ScalarspvNotificationSmsCountread-onlycurrentnumber of SMS receivers (both enabled or not)
1.3.6.1.4.1.6626.6000.4.1.19.2.2TablespvNotificationSmsTablenot-accessiblecurrentSMS receivers table
1.3.6.1.4.1.6626.6000.4.1.19.2.2.1RowspvNotificationSmsEntrynot-accessiblecurrentSMS receivers table entry
1.3.6.1.4.1.6626.6000.4.1.19.2.2.1.1ColumnspvNotificationSmsIndexnot-accessiblecurrentSMS receiver index
1.3.6.1.4.1.6626.6000.4.1.19.2.2.1.2ColumnspvNotificationSmsPhoneNumberread-createcurrentSMS receiver SIM number
1.3.6.1.4.1.6626.6000.4.1.19.2.2.1.3ColumnspvNotificationSmsAlarmSeverityread-createcurrentSMS receiver min severity for which is allowed the sending
1.3.6.1.4.1.6626.6000.4.1.19.2.2.1.4ColumnspvNotificationSmsHeartbeatEnableread-createcurrentenable/disable the SMS receiver to get a notification of the heartbeat
1.3.6.1.4.1.6626.6000.4.1.19.2.2.1.5ColumnspvNotificationSmsAlarmEnableread-createcurrentenable/disable the SMS receiver to get a notification of the alarm
1.3.6.1.4.1.6626.6000.4.1.19.2.3ScalarspvSmsFormatread-writecurrentformat for sms, classical or more readable one
1.3.6.1.4.1.6626.6000.4.1.19.3NodespvApn
1.3.6.1.4.1.6626.6000.4.1.19.3.1NodespvApnMisc
1.3.6.1.4.1.6626.6000.4.1.19.3.1.1ScalarspvApnCountread-onlycurrentcount of the GPRS operators present
1.3.6.1.4.1.6626.6000.4.1.19.3.1.2ScalarspvApnReadread-onlycurrentoperator read from modem
1.3.6.1.4.1.6626.6000.4.1.19.3.1.3ScalarspvApnSelectedread-writecurrentoperator selected from list
1.3.6.1.4.1.6626.6000.4.1.19.3.1.4ScalarspvApnAddUserread-onlycurrentadd if value = 1 a default new user
1.3.6.1.4.1.6626.6000.4.1.19.3.3TablespvApnTablenot-accessiblecurrentGPRS Operators table
1.3.6.1.4.1.6626.6000.4.1.19.3.3.1RowspvApnEntrynot-accessiblecurrentGPRS Operators table entry
1.3.6.1.4.1.6626.6000.4.1.19.3.3.1.1ColumnspvApnIndexnot-accessiblecurrentGPRS Operators index
1.3.6.1.4.1.6626.6000.4.1.19.3.3.1.2ColumnspvApnNameread-createcurrentGPRS Operators name
1.3.6.1.4.1.6626.6000.4.1.19.3.3.1.3ColumnspvApnUsernameread-createcurrentGPRS Operators username
1.3.6.1.4.1.6626.6000.4.1.19.3.3.1.4ColumnspvApnPwdread-createcurrentGPRS Operators password
1.3.6.1.4.1.6626.6000.4.1.19.3.3.1.5ColumnspvApnAuthread-createcurrentGPRS Operators authentication mode: CHAT/PAP
1.3.6.1.4.1.6626.6000.4.1.19.3.3.1.6ColumnspvApnAddressread-createcurrentGPRS Operators chat string
1.3.6.1.4.1.6626.6000.4.1.19.3.3.1.7ColumnspvApnStateread-createcurrentGPRS Operators state: active , not active
1.3.6.1.4.1.6626.6000.4.1.19.3.3.1.8ColumnspvApnDeleteread-createcurrentGPRS Operators delete command for current index
1.3.6.1.4.1.6626.6000.4.1.20NodespvEmail
1.3.6.1.4.1.6626.6000.4.1.20.1NodespvEmailParameters
1.3.6.1.4.1.6626.6000.4.1.20.1.1ScalarspvSmtpServerIpAddressread-writecurrentIP address of the Email server (SMTP)
1.3.6.1.4.1.6626.6000.4.1.20.1.2ScalarspvSmtpServerPortread-writecurrentport of the Email server (SMTP)
1.3.6.1.4.1.6626.6000.4.1.20.1.3ScalarspvEmailAddressread-writecurrentemail address of the board
1.3.6.1.4.1.6626.6000.4.1.20.1.4ScalarspvSmtpServerPresentread-writecurrenttells if the Email server (SMTP) is present
1.3.6.1.4.1.6626.6000.4.1.20.1.5ScalarspvSmtpServerIpAddress6read-writecurrentIP V6 address of the Email server (SMTP)
1.3.6.1.4.1.6626.6000.4.1.20.2NodespvNotificationEmail
1.3.6.1.4.1.6626.6000.4.1.20.2.1ScalarspvNotificationEmailCountread-onlycurrentnumber of emails receivers (both enabled or not)
1.3.6.1.4.1.6626.6000.4.1.20.2.2TablespvNotificationEmailTablenot-accessiblecurrentemail receivers table
1.3.6.1.4.1.6626.6000.4.1.20.2.2.1RowspvNotificationEmailEntrynot-accessiblecurrentemail receivers table entry
1.3.6.1.4.1.6626.6000.4.1.20.2.2.1.1ColumnspvNotificationEmailIndexnot-accessiblecurrentemails rx table index
1.3.6.1.4.1.6626.6000.4.1.20.2.2.1.2ColumnspvNotificationEmailAddressread-createcurrentemail of the operator
1.3.6.1.4.1.6626.6000.4.1.20.2.2.1.3ColumnspvNotificationEmailAlarmSeverityread-createcurrentemails receiver min severity for which is allowed the sending
1.3.6.1.4.1.6626.6000.4.1.20.2.2.1.4ColumnspvNotificationEmailHeartbeatEnableread-createcurrentenable/disable the emails receiver to get a notification of the heartbeat
1.3.6.1.4.1.6626.6000.4.1.20.2.2.1.5ColumnspvNotificationEmailAlarmEnableread-createcurrentenable/disable the emails receiver to get a notification of the alarm
1.3.6.1.4.1.6626.6000.4.1.21NodespvAlarmLog
1.3.6.1.4.1.6626.6000.4.1.21.1ScalarspvAlarmLogActiveCountread-onlycurrentnumber of active alarms present in the alarm log file
1.3.6.1.4.1.6626.6000.4.1.21.2ScalarspvAlarmLogMaxSeverityread-onlycurrentmax severity found in the alarm log
1.3.6.1.4.1.6626.6000.4.1.21.3ScalarspvAlarmLogEraseread-writecurrentcommand for erasing log of alarms
1.3.6.1.4.1.6626.6000.4.1.21.4TablespvAlarmLogTablenot-accessiblecurrentalarm log table
1.3.6.1.4.1.6626.6000.4.1.21.4.1RowspvAlarmLogEntrynot-accessiblecurrentalarms log table entry
1.3.6.1.4.1.6626.6000.4.1.21.4.1.1ColumnspvAlarmLogIdaccessible-for-notifycurrentalarm id in the log
1.3.6.1.4.1.6626.6000.4.1.21.4.1.2ColumnspvAlarmLogDeviceread-onlycurrentdevice of the alarm in the log
1.3.6.1.4.1.6626.6000.4.1.21.4.1.3ColumnspvAlarmLogAddressread-onlycurrentaddress of the module where the alarm has occurred
1.3.6.1.4.1.6626.6000.4.1.21.4.1.4ColumnspvAlarmLogAlarmNameread-onlycurrentname of the alarm in the log
1.3.6.1.4.1.6626.6000.4.1.21.4.1.5ColumnspvAlarmLogStartTimeread-onlycurrentdate and time when the alarm started
1.3.6.1.4.1.6626.6000.4.1.21.4.1.6ColumnspvAlarmLogEndTimeread-onlycurrentdate and time when the alarm ceased
1.3.6.1.4.1.6626.6000.4.1.21.4.1.7ColumnspvAlarmLogStateread-onlycurrentcurrent state of the alarm in the log
1.3.6.1.4.1.6626.6000.4.1.21.4.1.8ColumnspvAlarmLogSeverityread-onlycurrentseverity of the alarm
1.3.6.1.4.1.6626.6000.4.1.21.4.1.9ColumnspvAlarmLogTableIdxnot-accessiblecurrenttable id
1.3.6.1.4.1.6626.6000.4.1.21.4.1.10ColumnspvAlarmLogAlarmIdread-onlycurrentAlarm ID generated by the module
1.3.6.1.4.1.6626.6000.4.1.21.4.1.11ColumnspvAlarmLogModuleTypeNameread-onlycurrentModule Type name.
1.3.6.1.4.1.6626.6000.4.1.21.4.1.12ColumnspvAlarmLogModuleNameread-onlycurrentModule name set by the user. If module name is empty, the module type name is returned.
1.3.6.1.4.1.6626.6000.4.1.21.4.1.13ColumnspvAlarmLogModuleDescriptionread-onlycurrentModule description set by the user. Can be empty if not provided by the module protocol.
1.3.6.1.4.1.6626.6000.4.1.21.5ScalarspvAlarmLogTotalCountread-writecurrentnumber of alarms in the alarm log
1.3.6.1.4.1.6626.6000.4.1.21.6ScalarspvAlarmLogMaxStorableAlarmsread-writecurrentMax number of alarms storable in SPV system
1.3.6.1.4.1.6626.6000.4.1.22NodespvSystemInfo
1.3.6.1.4.1.6626.6000.4.1.22.1ScalarspvUptimeread-onlycurrentDays, hours, minutes and seconds since last restart
1.3.6.1.4.1.6626.6000.4.1.22.2ScalarspvUnitSystemread-writecurrentswitch metric / anglo-saxon system of measurement
1.3.6.1.4.1.6626.6000.4.1.22.3ScalarspvMemTotalread-onlycurrentmemory total
1.3.6.1.4.1.6626.6000.4.1.22.4ScalarspvMemAvailableread-onlycurrentmemory total
1.3.6.1.4.1.6626.6000.4.1.22.5ScalarspvMemUsedread-onlycurrentmemory total
1.3.6.1.4.1.6626.6000.4.1.22.6ScalarspvHdTotalread-onlycurrentmemory total
1.3.6.1.4.1.6626.6000.4.1.22.7ScalarspvHdAvailableread-onlycurrentmemory total
1.3.6.1.4.1.6626.6000.4.1.22.8ScalarspvHdUsedread-onlycurrentmemory total
1.3.6.1.4.1.6626.6000.4.1.23NodespvEventLog
1.3.6.1.4.1.6626.6000.4.1.23.1NodespvEventLogCommands
1.3.6.1.4.1.6626.6000.4.1.23.1.1ScalarspvEventLogClearread-writecurrentclear events from severity specified included
1.3.6.1.4.1.6626.6000.4.1.23.2NodespvEventLogParameters
1.3.6.1.4.1.6626.6000.4.1.23.2.1ScalarspvEventLogTotalread-onlycurrenttotal number of events in event log
1.3.6.1.4.1.6626.6000.4.1.24ScalarspvDiscoveryLastTimeread-onlycurrentlast discovery executed correctly
1.3.6.1.4.1.6626.6000.4.2NodespvMuContainer
1.3.6.1.4.1.6626.6000.4.2.1TablespvMuContainerTablenot-accessiblecurrentMaster Unit Container Table
1.3.6.1.4.1.6626.6000.4.2.1.1RowspvMuContainerEntrynot-accessiblecurrentsubrack table entry
1.3.6.1.4.1.6626.6000.4.2.1.1.1ColumnspvMuContainerIndexnot-accessiblecurrentMaster Unit Container Index
1.3.6.1.4.1.6626.6000.4.2.1.1.2ColumnspvMuContainerAlarmGlobalCountread-onlycurrentMaster Unit Container alarms global count
1.3.6.1.4.1.6626.6000.4.2.1.1.3ColumnspvMuContainerAlarmMaxSeverityread-onlycurrentMaster Unit Container alarms max severity
1.3.6.1.4.1.6626.6000.4.3NodespvSubrack
1.3.6.1.4.1.6626.6000.4.3.1TablespvSubrackTablenot-accessiblecurrentSubrack table
1.3.6.1.4.1.6626.6000.4.3.1.1RowspvSubrackEntrynot-accessiblecurrentSubrack row
1.3.6.1.4.1.6626.6000.4.3.1.1.1ColumnspvSubrackIndexnot-accessiblecurrentSubrack index
1.3.6.1.4.1.6626.6000.4.3.1.1.2ColumnspvSubrackAlarmGlobalCountread-onlycurrentSubrack alarms global count
1.3.6.1.4.1.6626.6000.4.3.1.1.3ColumnspvSubrackAlarmMaxSeverityread-onlycurrentsubrack alarms max severity
1.3.6.1.4.1.6626.6000.4.4NodespvMuSpv
1.3.6.1.4.1.6626.6000.4.4.1TablespvMuSpvTablenot-accessiblecurrentTBD
1.3.6.1.4.1.6626.6000.4.4.1.1RowspvMuSpvEntrynot-accessiblecurrentTBD
1.3.6.1.4.1.6626.6000.4.4.1.1.1ColumnspvMuSpvIndexnot-accessiblecurrentMaster unit index in the system (1-16)
1.3.6.1.4.1.6626.6000.4.4.1.1.2ColumnspvMuSpvTyperead-onlycurrentMaster Unit type
1.3.6.1.4.1.6626.6000.4.4.1.1.3ColumnspvMuSpvModelread-onlycurrentMaster Unit model
1.3.6.1.4.1.6626.6000.4.4.1.1.4ColumnspvMuSpvCommercialCoderead-onlycurrentMaster Unit sale code
1.3.6.1.4.1.6626.6000.4.4.1.1.5ColumnspvMuSpvCommercialDescriptionread-onlycurrentMaster Unit sale description
1.3.6.1.4.1.6626.6000.4.4.1.1.6ColumnspvMuSpvVersionread-onlycurrentMaster Unit version
1.3.6.1.4.1.6626.6000.4.4.1.1.7ColumnspvMuSpvNameread-writecurrentMaster Unit name
1.3.6.1.4.1.6626.6000.4.4.1.1.8ColumnspvMuSpvDescriptionread-writecurrentMaster Unit description
1.3.6.1.4.1.6626.6000.4.4.1.1.9ColumnspvMuSpvLocationLatituderead-writecurrentMaster Unit latitude
1.3.6.1.4.1.6626.6000.4.4.1.1.10ColumnspvMuSpvLocationLongituderead-writecurrentMaster Unit longitude
1.3.6.1.4.1.6626.6000.4.4.1.1.11ColumnspvMuSpvSerialNumberread-onlycurrentMaster Unit serial number
1.3.6.1.4.1.6626.6000.4.4.1.1.12ColumnspvMuSpvProductionDateread-onlycurrentMaster Unit production date
1.3.6.1.4.1.6626.6000.4.4.1.1.13ColumnspvMuSpvCommissionDateread-writecurrentMaster Unit commissioning date
1.3.6.1.4.1.6626.6000.4.4.1.1.14ColumnspvMuSpvTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.4.1.1.15ColumnspvMuSpvTemperatureread-onlycurrentTemperature
1.3.6.1.4.1.6626.6000.4.4.1.1.16ColumnspvMuSpvVendorIdread-onlycurrentMaster Unit SPV vendor Id
1.3.6.1.4.1.6626.6000.4.4.1.1.17ColumnspvMuSpvDataTimestampread-onlycurrentMaster Unit production date
1.3.6.1.4.1.6626.6000.4.4.1.1.18ColumnspvMuSpvDataSourceread-writecurrentMaster unit index in the system (1-16)
1.3.6.1.4.1.6626.6000.4.4.1.1.19ColumnspvMuSpvDataRestoreread-writecurrentMaster unit index in the system (1-16)
1.3.6.1.4.1.6626.6000.4.4.1.1.20ColumnspvMuSpvModeSelectorread-writecurrentMode selector
1.3.6.1.4.1.6626.6000.4.4.1.1.21ColumnspvMuSpvModeStatusread-onlycurrentMode status
1.3.6.1.4.1.6626.6000.4.4.2TablespvMuSpvRelayTablenot-accessiblecurrentRU relays table
1.3.6.1.4.1.6626.6000.4.4.2.1RowspvMuSpvRelayTableEntrynot-accessiblecurrentMU relay table entry
1.3.6.1.4.1.6626.6000.4.4.2.1.1ColumnspvMuSpvRelayIndexnot-accessiblecurrentindex of relay
1.3.6.1.4.1.6626.6000.4.4.2.1.2ColumnspvMuSpvRelayNameread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.4.2.1.3ColumnspvMuSpvRelayStateread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.4.2.1.4ColumnspvMuSpvRelayPolicyread-writecurrentrelay policy
1.3.6.1.4.1.6626.6000.4.4.2.1.5ColumnspvMuSpvRelayNcread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.4.3NodespvMuSpvAlarm
1.3.6.1.4.1.6626.6000.4.4.3.1TablespvMuSpvAlarmGlobalTablenot-accessiblecurrentmaster unit alarms global table
1.3.6.1.4.1.6626.6000.4.4.3.1.1RowspvMuSpvAlarmGlobalTableEntrynot-accessiblecurrentmaster unit alarms global table entry
1.3.6.1.4.1.6626.6000.4.4.3.1.1.1ColumnspvMuSpvAlarmGlobalCountread-onlycurrentmaster unit alarms global count
1.3.6.1.4.1.6626.6000.4.4.3.1.1.2ColumnspvMuSpvAlarmMaxSeverityread-onlycurrentmaster unit alarms max severity
1.3.6.1.4.1.6626.6000.4.4.3.1.1.3ColumnspvMuSpvReachableread-onlycurrentmaster unit reachable
1.3.6.1.4.1.6626.6000.4.4.3.2TablespvMuSpvAlarmTablenot-accessiblecurrentmaster unit alarm table
1.3.6.1.4.1.6626.6000.4.4.3.2.1RowspvMuSpvAlarmEntrynot-accessiblecurrentmaster unit alarm table entry
1.3.6.1.4.1.6626.6000.4.4.3.2.1.1ColumnspvMuSpvAlarmTypenot-accessiblecurrentSPV alarm type
1.3.6.1.4.1.6626.6000.4.4.3.2.1.2ColumnspvMuSpvAlarmEnableread-writecurrentSPV alarm enable
1.3.6.1.4.1.6626.6000.4.4.3.2.1.3ColumnspvMuSpvAlarmStateread-onlycurrentSPV alarm current state
1.3.6.1.4.1.6626.6000.4.4.3.2.1.4ColumnspvMuSpvAlarmSeverityread-writecurrentSPV alarm severity
1.3.6.1.4.1.6626.6000.4.4.3.2.1.5ColumnspvMuSpvAlarmPolarityread-writecurrentSPV alarm polarity
1.3.6.1.4.1.6626.6000.4.4.3.2.1.6ColumnspvMuSpvAlarmNameread-writecurrentSPV alarm name
1.3.6.1.4.1.6626.6000.4.5NodespvPsu
1.3.6.1.4.1.6626.6000.4.5.1TablespvPsuTablenot-accessiblecurrentPSU table
1.3.6.1.4.1.6626.6000.4.5.1.1RowspvPsuEntrynot-accessiblecurrentPSU table entry
1.3.6.1.4.1.6626.6000.4.5.1.1.1ColumnspvPsuIndexnot-accessiblecurrentPSU table index
1.3.6.1.4.1.6626.6000.4.5.1.1.2ColumnspvPsuTyperead-onlycurrentPSU type
1.3.6.1.4.1.6626.6000.4.5.1.1.3ColumnspvPsuModelread-onlycurrentPSU model
1.3.6.1.4.1.6626.6000.4.5.1.1.4ColumnspvPsuCommercialCoderead-onlycurrentPSU sale code
1.3.6.1.4.1.6626.6000.4.5.1.1.5ColumnspvPsuCommercialDescriptionread-onlycurrentPSU sale description
1.3.6.1.4.1.6626.6000.4.5.1.1.6ColumnspvPsuVersionread-onlycurrentPSU version
1.3.6.1.4.1.6626.6000.4.5.1.1.7ColumnspvPsuSerialNumberread-onlycurrentPSU serial number
1.3.6.1.4.1.6626.6000.4.5.1.1.8ColumnspvPsuProductionDateread-onlycurrentPSU production date
1.3.6.1.4.1.6626.6000.4.5.1.1.9ColumnspvPsuCommissionDateread-writecurrentPSU commissioning date
1.3.6.1.4.1.6626.6000.4.5.1.1.10ColumnspvPsuTemperatureread-onlycurrentPSU temperature in (C)
1.3.6.1.4.1.6626.6000.4.5.1.1.11ColumnspvPsuVoutread-onlycurrentPSU Vout in Volt
1.3.6.1.4.1.6626.6000.4.5.1.1.12ColumnspvPsuCurrentread-onlycurrentPSU current in mA
1.3.6.1.4.1.6626.6000.4.5.1.1.13ColumnspvPsuTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.5.1.1.14ColumnspvPsuVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.5.1.1.15ColumnspvPsuDataTimestampread-onlycurrentPSU production date
1.3.6.1.4.1.6626.6000.4.5.1.1.16ColumnspvPsuDataSourceread-writecurrentPSU table index
1.3.6.1.4.1.6626.6000.4.5.1.1.17ColumnspvPsuDataRestoreread-writecurrentPSU table index
1.3.6.1.4.1.6626.6000.4.5.2NodespvPsuAlarm
1.3.6.1.4.1.6626.6000.4.5.2.1TablespvPsuAlarmGlobalTablenot-accessiblecurrentPSU alarms global table
1.3.6.1.4.1.6626.6000.4.5.2.1.1RowspvPsuAlarmGlobalEntrynot-accessiblecurrentPSU alarms global table entry
1.3.6.1.4.1.6626.6000.4.5.2.1.1.1ColumnspvPsuAlarmGlobalCountread-onlycurrentPSU alarms global count
1.3.6.1.4.1.6626.6000.4.5.2.1.1.2ColumnspvPsuAlarmMaxSeverityread-onlycurrentPSU alarms max severity
1.3.6.1.4.1.6626.6000.4.5.2.1.1.3ColumnspvPsuReachableread-onlycurrentPSU reachable
1.3.6.1.4.1.6626.6000.4.5.2.2TablespvPsuAlarmTablenot-accessiblecurrentPSU alarms table
1.3.6.1.4.1.6626.6000.4.5.2.2.1RowspvPsuAlarmEntrynot-accessiblecurrentPSU alarms table entry
1.3.6.1.4.1.6626.6000.4.5.2.2.1.1ColumnspvPsuAlarmTypenot-accessiblecurrentPSU alarm type
1.3.6.1.4.1.6626.6000.4.5.2.2.1.2ColumnspvPsuAlarmEnableread-writecurrentPSU alarm enable
1.3.6.1.4.1.6626.6000.4.5.2.2.1.3ColumnspvPsuAlarmStateread-onlycurrentPSU alarm state
1.3.6.1.4.1.6626.6000.4.5.2.2.1.4ColumnspvPsuAlarmSeverityread-writecurrentPSU alarm severity
1.3.6.1.4.1.6626.6000.4.5.2.2.1.5ColumnspvPsuAlarmPolarityread-writecurrentPSU alarm polarity
1.3.6.1.4.1.6626.6000.4.5.2.2.1.6ColumnspvPsuAlarmNameread-writecurrentPSU alarm name
1.3.6.1.4.1.6626.6000.4.6NodespvMotrx
1.3.6.1.4.1.6626.6000.4.6.1TablespvMotrxTablenot-accessiblecurrentMotrx table
1.3.6.1.4.1.6626.6000.4.6.1.1RowspvMotrxEntrynot-accessiblecurrentMotrx table entry
1.3.6.1.4.1.6626.6000.4.6.1.1.1ColumnspvMotrxIndexnot-accessiblecurrentMotrx index
1.3.6.1.4.1.6626.6000.4.6.1.1.2ColumnspvMotrxTyperead-onlycurrentMotrx type
1.3.6.1.4.1.6626.6000.4.6.1.1.3ColumnspvMotrxModelread-onlycurrentMotrx model
1.3.6.1.4.1.6626.6000.4.6.1.1.4ColumnspvMotrxCommercialCoderead-onlycurrentMotrx sale code
1.3.6.1.4.1.6626.6000.4.6.1.1.5ColumnspvMotrxCommercialDescriptionread-onlycurrentMotrx sale description
1.3.6.1.4.1.6626.6000.4.6.1.1.6ColumnspvMotrxVersionread-onlycurrentMotrx version
1.3.6.1.4.1.6626.6000.4.6.1.1.7ColumnspvMotrxSerialNumberread-onlycurrentMotrx serial number
1.3.6.1.4.1.6626.6000.4.6.1.1.8ColumnspvMotrxProductionDateread-onlycurrentMotrx production date
1.3.6.1.4.1.6626.6000.4.6.1.1.9ColumnspvMotrxCommissionDateread-writecurrentMotrx commissioning date
1.3.6.1.4.1.6626.6000.4.6.1.1.10ColumnspvMotrxTemperatureread-onlycurrentMotrx temperature in (C)
1.3.6.1.4.1.6626.6000.4.6.1.1.11ColumnspvMotrxTxPwrread-onlycurrentMotrx Tx power (dBm)
1.3.6.1.4.1.6626.6000.4.6.1.1.12ColumnspvMotrxTxEnableread-writecurrentMotrx Tx enable
1.3.6.1.4.1.6626.6000.4.6.1.1.13ColumnspvMotrxTxAttAllUserread-writecurrentMotrx Tx common user attenuation (dB)
1.3.6.1.4.1.6626.6000.4.6.1.1.14ColumnspvMotrxRxAttAllUserread-writecurrentMotrx Rx common user attenuation (dB)
1.3.6.1.4.1.6626.6000.4.6.1.1.15ColumnspvMotrxTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.6.1.1.16ColumnspvMotrxVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.6.1.1.17ColumnspvMotrxDataTimestampread-onlycurrentMotrx production date
1.3.6.1.4.1.6626.6000.4.6.1.1.18ColumnspvMotrxDataSourceread-writecurrentMotrx index
1.3.6.1.4.1.6626.6000.4.6.1.1.19ColumnspvMotrxDataRestoreread-writecurrentMotrx index
1.3.6.1.4.1.6626.6000.4.6.1.1.20ColumnspvMotrxRxAtt2AllUserread-writecurrentMotrx Rx common user attenuation 2(dB)
1.3.6.1.4.1.6626.6000.4.6.1.1.21ColumnspvMotrxTxEnable2read-writecurrentMotrx Tx enable 2
1.3.6.1.4.1.6626.6000.4.6.1.1.22ColumnspvMotrxTxAttAllUser2read-writecurrentMotrx Tx common user attenuation 2(dB)
1.3.6.1.4.1.6626.6000.4.6.2TablespvMotrxRxTablenot-accessiblecurrentMotrx receivers table
1.3.6.1.4.1.6626.6000.4.6.2.1RowspvMotrxRxEntrynot-accessiblecurrentMotrx receivers table entry
1.3.6.1.4.1.6626.6000.4.6.2.1.1ColumnspvMotrxRxIndexnot-accessiblecurrentMotrx receiver index
1.3.6.1.4.1.6626.6000.4.6.2.1.2ColumnspvMotrxRxPwrChread-onlycurrentMotrx receiver power (dBm)
1.3.6.1.4.1.6626.6000.4.6.2.1.3ColumnspvMotrxRxEnableChread-writecurrentMotrx receiver enable
1.3.6.1.4.1.6626.6000.4.6.2.1.4ColumnspvMotrxRxAttUserChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.6.2.1.5ColumnspvMotrxRxFiberLossChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.6.3NodespvMotrxAlarm
1.3.6.1.4.1.6626.6000.4.6.3.1TablespvMotrxAlarmGlobalTablenot-accessiblecurrentMotrx alarms global table
1.3.6.1.4.1.6626.6000.4.6.3.1.1RowspvMotrxAlarmGlobalEntrynot-accessiblecurrentMotrx alarms global table entry
1.3.6.1.4.1.6626.6000.4.6.3.1.1.1ColumnspvMotrxAlarmGlobalCountread-onlycurrentMotrx alarms global count
1.3.6.1.4.1.6626.6000.4.6.3.1.1.2ColumnspvMotrxAlarmMaxSeverityread-onlycurrentMotrx alarms max severity
1.3.6.1.4.1.6626.6000.4.6.3.1.1.3ColumnspvMotrxReachableread-onlycurrentMotrx reachable
1.3.6.1.4.1.6626.6000.4.6.3.2TablespvMotrxAlarmTablenot-accessiblecurrentMotrx alarms table
1.3.6.1.4.1.6626.6000.4.6.3.2.1RowspvMotrxAlarmEntrynot-accessiblecurrentMotrx alarms table entry
1.3.6.1.4.1.6626.6000.4.6.3.2.1.1ColumnspvMotrxAlarmTypenot-accessiblecurrentMotrx alarm type
1.3.6.1.4.1.6626.6000.4.6.3.2.1.2ColumnspvMotrxAlarmEnableread-writecurrentMotrx alarm enable
1.3.6.1.4.1.6626.6000.4.6.3.2.1.3ColumnspvMotrxAlarmStateread-onlycurrentMotrx alarm state
1.3.6.1.4.1.6626.6000.4.6.3.2.1.4ColumnspvMotrxAlarmSeverityread-onlycurrentMotrx alarm severity
1.3.6.1.4.1.6626.6000.4.6.3.2.1.5ColumnspvMotrxAlarmPolarityread-onlycurrentMotrx alarm polarity
1.3.6.1.4.1.6626.6000.4.6.3.2.1.6ColumnspvMotrxAlarmNameread-onlycurrentMotrx alarm name
1.3.6.1.4.1.6626.6000.4.7NodespvPtp
1.3.6.1.4.1.6626.6000.4.7.1TablespvPtpTablenot-accessiblecurrentPtoP table
1.3.6.1.4.1.6626.6000.4.7.1.1RowspvPtpEntrynot-accessiblecurrentPtoP table entry
1.3.6.1.4.1.6626.6000.4.7.1.1.1ColumnspvPtpIndexnot-accessiblecurrentPtoP index
1.3.6.1.4.1.6626.6000.4.7.1.1.2ColumnspvPtpTyperead-onlycurrentPtoP type
1.3.6.1.4.1.6626.6000.4.7.1.1.3ColumnspvPtpModelread-onlycurrentPtoP model
1.3.6.1.4.1.6626.6000.4.7.1.1.4ColumnspvPtpCommercialCoderead-onlycurrentPtoP sale code
1.3.6.1.4.1.6626.6000.4.7.1.1.5ColumnspvPtpCommercialDescriptionread-onlycurrentPtoP sale description
1.3.6.1.4.1.6626.6000.4.7.1.1.6ColumnspvPtpVersionread-onlycurrentPtoP version
1.3.6.1.4.1.6626.6000.4.7.1.1.7ColumnspvPtpSerialNumberread-onlycurrentPtoP serial number
1.3.6.1.4.1.6626.6000.4.7.1.1.8ColumnspvPtpProductionDateread-onlycurrentPtoP production date
1.3.6.1.4.1.6626.6000.4.7.1.1.9ColumnspvPtpCommissionDateread-writecurrentPtoP commissioning date
1.3.6.1.4.1.6626.6000.4.7.1.1.10ColumnspvPtpNameread-writecurrentPtoP name
1.3.6.1.4.1.6626.6000.4.7.1.1.11ColumnspvPtpDescriptionread-writecurrentPtoP production date
1.3.6.1.4.1.6626.6000.4.7.1.1.12ColumnspvPtpLocationLatituderead-writecurrentPtoP location latitude
1.3.6.1.4.1.6626.6000.4.7.1.1.13ColumnspvPtpLocationLongituderead-writecurrentPtoP location longitude
1.3.6.1.4.1.6626.6000.4.7.1.1.14ColumnspvPtpTemperatureread-onlycurrentPtoP temperature
1.3.6.1.4.1.6626.6000.4.7.1.1.15ColumnspvPtpPwrTxread-onlycurrentPtoP power TX
1.3.6.1.4.1.6626.6000.4.7.1.1.16ColumnspvPtpPwrRxread-onlycurrentPtoP power received
1.3.6.1.4.1.6626.6000.4.7.1.1.17ColumnspvPtpAttTxread-writecurrentPtoP att TX
1.3.6.1.4.1.6626.6000.4.7.1.1.18ColumnspvPtpAttRxInread-writecurrentPtoP att rx in
1.3.6.1.4.1.6626.6000.4.7.1.1.19ColumnspvPtpAttRxOutread-writecurrentPtoP att rx out
1.3.6.1.4.1.6626.6000.4.7.1.1.20ColumnspvPtpEnableTxread-writecurrentPtoP enable tx
1.3.6.1.4.1.6626.6000.4.7.1.1.21ColumnspvPtpTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.7.1.1.22ColumnspvPtpVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.7.1.1.23ColumnspvPtpFiberLossread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.7.1.1.24ColumnspvPtpDataTimestampread-onlycurrentPtoP production date
1.3.6.1.4.1.6626.6000.4.7.1.1.25ColumnspvPtpDataSourceread-writecurrentPtoP index
1.3.6.1.4.1.6626.6000.4.7.1.1.26ColumnspvPtpDataRestoreread-writecurrentPtoP index
1.3.6.1.4.1.6626.6000.4.7.2NodespvPtpAlarm
1.3.6.1.4.1.6626.6000.4.7.2.1TablespvPtpAlarmGlobalTablenot-accessiblecurrentPtoP alarms global table
1.3.6.1.4.1.6626.6000.4.7.2.1.1RowspvPtpAlarmGlobalEntrynot-accessiblecurrentPtoP alarms global table entry
1.3.6.1.4.1.6626.6000.4.7.2.1.1.1ColumnspvPtpAlarmGlobalCountread-onlycurrentPtoP alarms global count
1.3.6.1.4.1.6626.6000.4.7.2.1.1.2ColumnspvPtpAlarmMaxSeverityread-onlycurrentPtoP alarms max severity
1.3.6.1.4.1.6626.6000.4.7.2.1.1.3ColumnspvPtpReachableread-onlycurrentPtoP reachable
1.3.6.1.4.1.6626.6000.4.7.2.2TablespvPtpAlarmTablenot-accessiblecurrentPtoP alarms table
1.3.6.1.4.1.6626.6000.4.7.2.2.1RowspvPtpAlarmEntrynot-accessiblecurrentPtoP alarms table entry
1.3.6.1.4.1.6626.6000.4.7.2.2.1.1ColumnspvPtpAlarmTypenot-accessiblecurrentPtoP alarm type
1.3.6.1.4.1.6626.6000.4.7.2.2.1.2ColumnspvPtpAlarmEnableread-writecurrentPtoP alarm enable
1.3.6.1.4.1.6626.6000.4.7.2.2.1.3ColumnspvPtpAlarmStateread-onlycurrentPtoP alarm state
1.3.6.1.4.1.6626.6000.4.7.2.2.1.4ColumnspvPtpAlarmSeverityread-writecurrentPtoP alarm severity
1.3.6.1.4.1.6626.6000.4.7.2.2.1.5ColumnspvPtpAlarmPolarityread-writecurrentPtoP alarm polarity
1.3.6.1.4.1.6626.6000.4.7.2.2.1.6ColumnspvPtpAlarmNameread-onlycurrentPtoP alarm name
1.3.6.1.4.1.6626.6000.4.8NodespvRu
1.3.6.1.4.1.6626.6000.4.8.1TablespvRuTablenot-accessiblecurrentRU-SPV table
1.3.6.1.4.1.6626.6000.4.8.1.1RowspvRuEntrynot-accessiblecurrentRU-SPV table entry
1.3.6.1.4.1.6626.6000.4.8.1.1.1ColumnspvRuIndexnot-accessiblecurrentRU-SPV index
1.3.6.1.4.1.6626.6000.4.8.1.1.2ColumnspvRuTyperead-onlycurrentRU-SPV type
1.3.6.1.4.1.6626.6000.4.8.1.1.3ColumnspvRuModelread-onlycurrentRU-SPV model
1.3.6.1.4.1.6626.6000.4.8.1.1.4ColumnspvRuCommercialCoderead-onlycurrentRU-SPV sale code
1.3.6.1.4.1.6626.6000.4.8.1.1.5ColumnspvRuCommercialDescriptionread-onlycurrentRU-SPV sale description
1.3.6.1.4.1.6626.6000.4.8.1.1.6ColumnspvRuVersionread-onlycurrentRU-SPV version
1.3.6.1.4.1.6626.6000.4.8.1.1.7ColumnspvRuNameread-writecurrentRU-SPV name
1.3.6.1.4.1.6626.6000.4.8.1.1.8ColumnspvRuDescriptionread-writecurrentRU-SPV production date
1.3.6.1.4.1.6626.6000.4.8.1.1.9ColumnspvRuLocationLatituderead-writecurrentRU-SPV location latitude
1.3.6.1.4.1.6626.6000.4.8.1.1.10ColumnspvRuLocationLongituderead-writecurrentRU-SPV location longitude
1.3.6.1.4.1.6626.6000.4.8.1.1.11ColumnspvRuSerialNumberread-onlycurrentRU-SPV serial number
1.3.6.1.4.1.6626.6000.4.8.1.1.12ColumnspvRuProductionDateread-onlycurrentRU-SPV production date
1.3.6.1.4.1.6626.6000.4.8.1.1.13ColumnspvRuCommissionDateread-writecurrentRU-SPV commissioning date
1.3.6.1.4.1.6626.6000.4.8.1.1.14ColumnspvRuTemperatureread-onlycurrentRU-SPV temperature in (C)
1.3.6.1.4.1.6626.6000.4.8.1.1.15ColumnspvRuBoardCurrentread-onlycurrentRU-SPV board current in (C)
1.3.6.1.4.1.6626.6000.4.8.1.1.16ColumnspvRuPsu1Currentread-onlycurrentRU-SPV PSU1 current in (C)
1.3.6.1.4.1.6626.6000.4.8.1.1.17ColumnspvRuPsu2Currentread-onlycurrentRU-SPV PSU2 current in (C)
1.3.6.1.4.1.6626.6000.4.8.1.1.18ColumnspvRuPsuVoutread-onlycurrentRU-SPV PSU Vout in (V)
1.3.6.1.4.1.6626.6000.4.8.1.1.19ColumnspvRuPsuCurrent3read-onlycurrentRU-SPV PSU current in Ampere
1.3.6.1.4.1.6626.6000.4.8.1.1.20ColumnspvRuPsu1Temperatureread-onlycurrentTemperature of the PSU1 in C degree
1.3.6.1.4.1.6626.6000.4.8.1.1.21ColumnspvRuPsu2Temperatureread-onlycurrentTemperature of the PSU2 in C degree
1.3.6.1.4.1.6626.6000.4.8.1.1.22ColumnspvRuTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.8.1.1.23ColumnspvRuVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.8.1.1.24ColumnspvRuDataTimestampread-onlycurrentRU-SPV production date
1.3.6.1.4.1.6626.6000.4.8.1.1.25ColumnspvRuDataSourceread-writecurrentRU-SPV index
1.3.6.1.4.1.6626.6000.4.8.1.1.26ColumnspvRuDataRestoreread-writecurrentRU-SPV index
1.3.6.1.4.1.6626.6000.4.8.1.1.27ColumnspvRuFansNumberread-onlycurrent0 = 3fans, 1 = 2 fans
1.3.6.1.4.1.6626.6000.4.8.2TablespvRuFanTablenot-accessiblecurrentRU-SPV fan table
1.3.6.1.4.1.6626.6000.4.8.2.1RowspvRuFanEntrynot-accessiblecurrentRU-SPV fan table entry
1.3.6.1.4.1.6626.6000.4.8.2.1.1ColumnspvRuFanIndexnot-accessiblecurrentRU-SPV fan table index
1.3.6.1.4.1.6626.6000.4.8.2.1.2ColumnspvRuFanEnableread-onlycurrentRU-SPV fan enable
1.3.6.1.4.1.6626.6000.4.8.2.1.3ColumnspvRuFanSpeedReadread-onlycurrentRU-SPV fan speed read in rpm
1.3.6.1.4.1.6626.6000.4.8.2.1.4ColumnspvRuFanSpeedPercentageread-onlycurrentRU-SPV fan speed read in rpm
1.3.6.1.4.1.6626.6000.4.8.3TablespvRuRelayTablenot-accessiblecurrentRU relays table
1.3.6.1.4.1.6626.6000.4.8.3.1RowspvRuRelayEntrynot-accessiblecurrentRU relay table entry
1.3.6.1.4.1.6626.6000.4.8.3.1.1ColumnspvRuRelayIndexnot-accessiblecurrentIndex of relay
1.3.6.1.4.1.6626.6000.4.8.3.1.2ColumnspvRuRelayStateread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.8.3.1.3ColumnspvRuRelayNameread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.8.3.1.4ColumnspvRuRelayPolicyread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.8.3.1.5ColumnspvRuRelayNcread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.8.4NodespvRuAlarm
1.3.6.1.4.1.6626.6000.4.8.4.1TablespvRuAlarmGlobalTablenot-accessiblecurrentRU-SPV alarms global table
1.3.6.1.4.1.6626.6000.4.8.4.1.1RowspvRuAlarmGlobalEntrynot-accessiblecurrentRU-SPV alarms global table entry
1.3.6.1.4.1.6626.6000.4.8.4.1.1.1ColumnspvRuAlarmGlobalCountread-onlycurrentRU-SPV alarms global count
1.3.6.1.4.1.6626.6000.4.8.4.1.1.2ColumnspvRuAlarmMaxSeverityread-onlycurrentRU-SPV alarms max severity
1.3.6.1.4.1.6626.6000.4.8.4.1.1.3ColumnspvRuReachableread-onlycurrentmodule communication state
1.3.6.1.4.1.6626.6000.4.8.4.2TablespvRuAlarmTablenot-accessiblecurrentRU-SPV alarms table
1.3.6.1.4.1.6626.6000.4.8.4.2.1RowspvRuAlarmEntrynot-accessiblecurrentRU-SPV alarms table entry
1.3.6.1.4.1.6626.6000.4.8.4.2.1.1ColumnspvRuAlarmTypenot-accessiblecurrentRU-SPV alarm type
1.3.6.1.4.1.6626.6000.4.8.4.2.1.2ColumnspvRuAlarmEnableread-writecurrentRU-SPV alarm enable
1.3.6.1.4.1.6626.6000.4.8.4.2.1.3ColumnspvRuAlarmStateread-onlycurrentRU-SPV alarm state
1.3.6.1.4.1.6626.6000.4.8.4.2.1.4ColumnspvRuAlarmSeverityread-writecurrentRU-SPV alarm severity
1.3.6.1.4.1.6626.6000.4.8.4.2.1.5ColumnspvRuAlarmPolarityread-writecurrentSPV-RU alarm polarity
1.3.6.1.4.1.6626.6000.4.8.4.2.1.6ColumnspvRuAlarmNameread-writecurrentRU-SPV alarm name
1.3.6.1.4.1.6626.6000.4.9NodespvRotrx
1.3.6.1.4.1.6626.6000.4.9.1TablespvRotrxTablenot-accessiblecurrentR-OTRX TABLE
1.3.6.1.4.1.6626.6000.4.9.1.1RowspvRotrxEntrynot-accessiblecurrentR-OTRX TABLE Entry
1.3.6.1.4.1.6626.6000.4.9.1.1.1ColumnspvRotrxIndexnot-accessiblecurrentR-OTRX TABLE index
1.3.6.1.4.1.6626.6000.4.9.1.1.2ColumnspvRotrxTyperead-onlycurrentR-OTRX type
1.3.6.1.4.1.6626.6000.4.9.1.1.3ColumnspvRotrxModelread-onlycurrentR-OTRX model
1.3.6.1.4.1.6626.6000.4.9.1.1.4ColumnspvRotrxCommercialCoderead-onlycurrentR-OTRX sale code
1.3.6.1.4.1.6626.6000.4.9.1.1.5ColumnspvRotrxCommercialDescriptionread-onlycurrentR-OTRX sale description
1.3.6.1.4.1.6626.6000.4.9.1.1.6ColumnspvRotrxVersionread-onlycurrentR-OTRX version
1.3.6.1.4.1.6626.6000.4.9.1.1.7ColumnspvRotrxSerialNumberread-onlycurrentR-OTRX serial number
1.3.6.1.4.1.6626.6000.4.9.1.1.8ColumnspvRotrxProductionDateread-onlycurrentR-OTRX production date
1.3.6.1.4.1.6626.6000.4.9.1.1.9ColumnspvRotrxCommissionDateread-writecurrentR-OTRX commissioning date
1.3.6.1.4.1.6626.6000.4.9.1.1.10ColumnspvRotrxTemperatureread-onlycurrentR-OTRX temperature in C degrees
1.3.6.1.4.1.6626.6000.4.9.1.1.11ColumnspvRotrxPwrTxread-onlycurrentR-OTRX tranmitted power
1.3.6.1.4.1.6626.6000.4.9.1.1.12ColumnspvRotrxPwrRxread-onlycurrentR-OTRX received power
1.3.6.1.4.1.6626.6000.4.9.1.1.13ColumnspvRotrxTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.9.1.1.14ColumnspvRotrxVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.9.1.1.15ColumnspvRotrxFiberLossread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.9.1.1.16ColumnspvRotrxDataTimestampread-onlycurrentR-OTRX production date
1.3.6.1.4.1.6626.6000.4.9.1.1.17ColumnspvRotrxDataSourceread-writecurrentRotrx index
1.3.6.1.4.1.6626.6000.4.9.1.1.18ColumnspvRotrxDataRestoreread-writecurrentRotrx index
1.3.6.1.4.1.6626.6000.4.9.1.1.19ColumnspvRotrxPwrTx2read-onlycurrentR-OTRX tranmitted power
1.3.6.1.4.1.6626.6000.4.9.1.1.20ColumnspvRotrxPwrRx2read-onlycurrentR-OTRX received power
1.3.6.1.4.1.6626.6000.4.9.1.1.21ColumnspvRotrxFiberLoss2read-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.9.2TablespvRotrxChannelTablenot-accessiblecurrentR-OTRX channels
1.3.6.1.4.1.6626.6000.4.9.2.1RowspvRotrxChannelEntrynot-accessiblecurrentR-OTRX channel entry
1.3.6.1.4.1.6626.6000.4.9.2.1.1ColumnspvRotrxChannelIndexnot-accessiblecurrentR-OTRX channel index
1.3.6.1.4.1.6626.6000.4.9.2.1.2ColumnspvRotrxAttUlChread-writecurrentR-OTRX channel attenuation in dB
1.3.6.1.4.1.6626.6000.4.9.2.1.3ColumnspvRotrxAttDlChread-writecurrentR-OTRX channel attenuation in dB
1.3.6.1.4.1.6626.6000.4.9.2.1.4ColumnspvRotrxPwrUlChread-writecurrentR-OTRX channel attenuation in dB
1.3.6.1.4.1.6626.6000.4.9.3NodespvRotrxAlarm
1.3.6.1.4.1.6626.6000.4.9.3.1TablespvRotrxAlarmGlobalTablenot-accessiblecurrentROTRX alarms global table
1.3.6.1.4.1.6626.6000.4.9.3.1.1RowspvRotrxAlarmGlobalEntrynot-accessiblecurrentROTRX alarms global table entry
1.3.6.1.4.1.6626.6000.4.9.3.1.1.1ColumnspvRotrxAlarmGlobalCountread-onlycurrentROTRX alarms global count
1.3.6.1.4.1.6626.6000.4.9.3.1.1.2ColumnspvRotrxAlarmMaxSeverityread-onlycurrentROTRX alarms max severity
1.3.6.1.4.1.6626.6000.4.9.3.1.1.3ColumnspvRotrxReachableread-onlycurrentROTRX reachable
1.3.6.1.4.1.6626.6000.4.9.3.2TablespvRotrxAlarmTablenot-accessiblecurrentROTRX alarms table
1.3.6.1.4.1.6626.6000.4.9.3.2.1RowspvRotrxAlarmEntrynot-accessiblecurrentROTRX alarms table entry
1.3.6.1.4.1.6626.6000.4.9.3.2.1.1ColumnspvRotrxAlarmTypenot-accessiblecurrentROTRX alarm type
1.3.6.1.4.1.6626.6000.4.9.3.2.1.2ColumnspvRotrxAlarmEnableread-writecurrentROTRX alarm enable
1.3.6.1.4.1.6626.6000.4.9.3.2.1.3ColumnspvRotrxAlarmStateread-onlycurrentROTRX alarm state
1.3.6.1.4.1.6626.6000.4.9.3.2.1.4ColumnspvRotrxAlarmSeverityread-writecurrentROTRX alarm severity
1.3.6.1.4.1.6626.6000.4.9.3.2.1.5ColumnspvRotrxAlarmPolarityread-writecurrentROTRX alarm polarity
1.3.6.1.4.1.6626.6000.4.9.3.2.1.6ColumnspvRotrxAlarmNameread-onlycurrentROTRX alarm name
1.3.6.1.4.1.6626.6000.4.10NodespvHpa
1.3.6.1.4.1.6626.6000.4.10.1TablespvHpaTablenot-accessiblecurrentRU-HPA table
1.3.6.1.4.1.6626.6000.4.10.1.1RowspvHpaEntrynot-accessiblecurrentRU-HPA table entry
1.3.6.1.4.1.6626.6000.4.10.1.1.1ColumnspvHpaIndexnot-accessiblecurrentRU-HPA table index
1.3.6.1.4.1.6626.6000.4.10.1.1.2ColumnspvHpaTyperead-onlycurrentRU-HPA type
1.3.6.1.4.1.6626.6000.4.10.1.1.3ColumnspvHpaModelread-onlycurrentRU-HPA model
1.3.6.1.4.1.6626.6000.4.10.1.1.4ColumnspvHpaCommercialCoderead-onlycurrentRU-HPA sale code
1.3.6.1.4.1.6626.6000.4.10.1.1.5ColumnspvHpaCommercialDescriptionread-onlycurrentRU-HPA sale description
1.3.6.1.4.1.6626.6000.4.10.1.1.6ColumnspvHpaVersionread-onlycurrentRU-HPA version
1.3.6.1.4.1.6626.6000.4.10.1.1.7ColumnspvHpaSerialNumberread-onlycurrentRU-HPA serial number
1.3.6.1.4.1.6626.6000.4.10.1.1.8ColumnspvHpaProductionDateread-onlycurrentRU-HPA production date
1.3.6.1.4.1.6626.6000.4.10.1.1.9ColumnspvHpaCommissionDateread-writecurrentRU-HPA commissioning date
1.3.6.1.4.1.6626.6000.4.10.1.1.10ColumnspvHpaRfEnableread-writecurrentRU-HPA RF enable ON/OFF
1.3.6.1.4.1.6626.6000.4.10.1.1.11ColumnspvHpaTemperatureread-onlycurrentRU-HPA temperature in C degrees
1.3.6.1.4.1.6626.6000.4.10.1.1.12ColumnspvHpaPwrread-onlycurrentRU-HPA out power in dBm
1.3.6.1.4.1.6626.6000.4.10.1.1.13ColumnspvHpaTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.10.1.1.14ColumnspvHpaVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.10.1.1.15ColumnspvHpaDataTimestampread-onlycurrentRU-HPA production date
1.3.6.1.4.1.6626.6000.4.10.1.1.16ColumnspvHpaDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.10.1.1.17ColumnspvHpaDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.10.1.1.18ColumnspvHpaAttread-writecurrentAttenuation
1.3.6.1.4.1.6626.6000.4.10.2NodespvHpaAlarm
1.3.6.1.4.1.6626.6000.4.10.2.1TablespvHpaAlarmGlobalTablenot-accessiblecurrentRU-HPA alarms global table
1.3.6.1.4.1.6626.6000.4.10.2.1.1RowspvHpaAlarmGlobalEntrynot-accessiblecurrentRU-HPA alarms global table entry
1.3.6.1.4.1.6626.6000.4.10.2.1.1.1ColumnspvHpaAlarmGlobalCountread-onlycurrentRU-HPA alarms global count
1.3.6.1.4.1.6626.6000.4.10.2.1.1.2ColumnspvHpaAlarmMaxSeverityread-onlycurrentRU-HPA alarms max severity
1.3.6.1.4.1.6626.6000.4.10.2.1.1.3ColumnspvHpaReachableread-onlycurrentRU-HPA reachable
1.3.6.1.4.1.6626.6000.4.10.2.2TablespvHpaAlarmTablenot-accessiblecurrentRU-HPA alarms table
1.3.6.1.4.1.6626.6000.4.10.2.2.1RowspvHpaAlarmEntrynot-accessiblecurrentRU-HPA alarms table entry
1.3.6.1.4.1.6626.6000.4.10.2.2.1.1ColumnspvHpaAlarmTypenot-accessiblecurrentRU-HPA alarm type
1.3.6.1.4.1.6626.6000.4.10.2.2.1.2ColumnspvHpaAlarmEnableread-writecurrentRU-HPA alarm enable
1.3.6.1.4.1.6626.6000.4.10.2.2.1.3ColumnspvHpaAlarmStateread-onlycurrentRU-HPA alarm state
1.3.6.1.4.1.6626.6000.4.10.2.2.1.4ColumnspvHpaAlarmSeverityread-writecurrentRU-HPA alarm severity
1.3.6.1.4.1.6626.6000.4.10.2.2.1.5ColumnspvHpaAlarmPolarityread-writecurrentRU-HPA alarm polarity
1.3.6.1.4.1.6626.6000.4.10.2.2.1.6ColumnspvHpaAlarmNameread-onlycurrentRU-HPA alarm name
1.3.6.1.4.1.6626.6000.4.11NodespvMpa
1.3.6.1.4.1.6626.6000.4.11.1TablespvMpaTablenot-accessiblecurrentRU-MPA table
1.3.6.1.4.1.6626.6000.4.11.1.1RowspvMpaEntrynot-accessiblecurrentRU-MPA table entry
1.3.6.1.4.1.6626.6000.4.11.1.1.1ColumnspvMpaIndexnot-accessiblecurrentRU-MPA table index
1.3.6.1.4.1.6626.6000.4.11.1.1.2ColumnspvMpaTyperead-onlycurrentRU-MPA type
1.3.6.1.4.1.6626.6000.4.11.1.1.3ColumnspvMpaModelread-onlycurrentRU-MPA model
1.3.6.1.4.1.6626.6000.4.11.1.1.4ColumnspvMpaCommercialCoderead-onlycurrentRU-MPA sale code
1.3.6.1.4.1.6626.6000.4.11.1.1.5ColumnspvMpaCommercialDescriptionread-onlycurrentRU-MPA sale description
1.3.6.1.4.1.6626.6000.4.11.1.1.6ColumnspvMpaVersionread-onlycurrentRU-MPA version
1.3.6.1.4.1.6626.6000.4.11.1.1.7ColumnspvMpaSerialNumberread-onlycurrentRU-MPA serial number
1.3.6.1.4.1.6626.6000.4.11.1.1.8ColumnspvMpaProductionDateread-onlycurrentRU-MPA production date
1.3.6.1.4.1.6626.6000.4.11.1.1.9ColumnspvMpaCommissionDateread-writecurrentRU-MPA commissioning date
1.3.6.1.4.1.6626.6000.4.11.1.1.10ColumnspvMpaRfEnableread-writecurrentRU-MPA RF enable (ON/OFF)
1.3.6.1.4.1.6626.6000.4.11.1.1.11ColumnspvMpaTemperatureread-onlycurrentRU-MPA temperature in C degrees
1.3.6.1.4.1.6626.6000.4.11.1.1.12ColumnspvMpaPwrread-onlycurrentRU-MPA out power in dB
1.3.6.1.4.1.6626.6000.4.11.1.1.13ColumnspvMpaTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.11.1.1.14ColumnspvMpaVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.11.1.1.15ColumnspvMpaDataTimestampread-onlycurrentRU-MPA production date
1.3.6.1.4.1.6626.6000.4.11.1.1.16ColumnspvMpaDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.11.1.1.17ColumnspvMpaDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.11.2NodespvMpaAlarm
1.3.6.1.4.1.6626.6000.4.11.2.1TablespvMpaAlarmGlobalTablenot-accessiblecurrentRU-MPA alarms global table
1.3.6.1.4.1.6626.6000.4.11.2.1.1RowspvMpaAlarmGlobalEntrynot-accessiblecurrentRU-MPA alarms global table entry
1.3.6.1.4.1.6626.6000.4.11.2.1.1.1ColumnspvMpaAlarmGlobalCountread-onlycurrentRU-MPA alarms global table global count
1.3.6.1.4.1.6626.6000.4.11.2.1.1.2ColumnspvMpaAlarmMaxSeverityread-onlycurrentRU-MPA alarms global table max severity
1.3.6.1.4.1.6626.6000.4.11.2.1.1.3ColumnspvMpaReachableread-onlycurrentRU-MPA reachable
1.3.6.1.4.1.6626.6000.4.11.2.2TablespvMpaAlarmTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.11.2.2.1RowspvMpaAlarmEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.11.2.2.1.1ColumnspvMpaAlarmTypenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.11.2.2.1.2ColumnspvMpaAlarmEnableread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.11.2.2.1.3ColumnspvMpaAlarmStateread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.11.2.2.1.4ColumnspvMpaAlarmSeverityread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.11.2.2.1.5ColumnspvMpaAlarmPolarityread-writecurrentPolarity
1.3.6.1.4.1.6626.6000.4.11.2.2.1.6ColumnspvMpaAlarmNameread-onlycurrentRU-MPA alarm name
1.3.6.1.4.1.6626.6000.4.12NodespvRuLp
1.3.6.1.4.1.6626.6000.4.12.1TablespvRuLpTablenot-accessiblecurrent
1.3.6.1.4.1.6626.6000.4.12.1.1RowspvRuLpEntrynot-accessiblecurrent
1.3.6.1.4.1.6626.6000.4.12.1.1.1ColumnspvRuLpIndexnot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.2ColumnspvRuLpTyperead-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.3ColumnspvRuLpModelread-onlycurrent
1.3.6.1.4.1.6626.6000.4.12.1.1.4ColumnspvRuLpCommercialCoderead-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.5ColumnspvRuLpCommercialDescriptionread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.6ColumnspvRuLpVersionread-onlycurrent
1.3.6.1.4.1.6626.6000.4.12.1.1.7ColumnspvRuLpNameread-writecurrent
1.3.6.1.4.1.6626.6000.4.12.1.1.8ColumnspvRuLpDescriptionread-writecurrent
1.3.6.1.4.1.6626.6000.4.12.1.1.9ColumnspvRuLpLocationLatituderead-writecurrent
1.3.6.1.4.1.6626.6000.4.12.1.1.10ColumnspvRuLpLocationLongituderead-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.11ColumnspvRuLpSerialNumberread-onlycurrent
1.3.6.1.4.1.6626.6000.4.12.1.1.12ColumnspvRuLpProductionDateread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.13ColumnspvRuLpCommissionDateread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.14ColumnspvRuLpTemperatureread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.15ColumnspvRuLpPsuVoutread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.16ColumnspvRuLpPwrTxread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.17ColumnspvRuLpPwrRxread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.18ColumnspvRuLpTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.12.1.1.19ColumnspvRuLpVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.12.1.1.20ColumnspvRuLpFiberLossread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.12.1.1.21ColumnspvRuLpDataTimestampread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.1.1.22ColumnspvRuLpDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.12.1.1.23ColumnspvRuLpDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.12.1.1.24ColumnspvRuLpPwrTx2read-onlycurrentTx Power of Ch2
1.3.6.1.4.1.6626.6000.4.12.1.1.25ColumnspvRuLpPwrRx2read-onlycurrentRx Power of Ch2
1.3.6.1.4.1.6626.6000.4.12.1.1.26ColumnspvRuLpFiberLoss2read-onlycurrentFiber Loss on Ch2
1.3.6.1.4.1.6626.6000.4.12.2TablespvRuLpChTablenot-accessiblecurrentRULP channels table
1.3.6.1.4.1.6626.6000.4.12.2.1RowspvRuLpChEntrynot-accessiblecurrentRULP channels table entry
1.3.6.1.4.1.6626.6000.4.12.2.1.1ColumnspvRuLpChIndexnot-accessiblecurrentindex of the channel
1.3.6.1.4.1.6626.6000.4.12.2.1.2ColumnspvRuLpAttUlChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.2.1.3ColumnspvRuLpAttDlChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.2.1.4ColumnspvRuLpRfEnableChread-writecurrentEnable/Disable RF Channel.
1.3.6.1.4.1.6626.6000.4.12.2.1.5ColumnspvRuLpPwrUlChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.2.1.6ColumnspvRuLpPwrDlChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.3TablespvRuLpRelayTablenot-accessiblecurrentRULP relays table
1.3.6.1.4.1.6626.6000.4.12.3.1RowspvRuLpRelayEntrynot-accessiblecurrentRULP relay table entry
1.3.6.1.4.1.6626.6000.4.12.3.1.1ColumnspvRuLpRelayIndexnot-accessiblecurrentindex of relay
1.3.6.1.4.1.6626.6000.4.12.3.1.2ColumnspvRuLpRelayStateread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.3.1.3ColumnspvRuLpRelayNameread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.3.1.4ColumnspvRuLpRelayPolicyread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.3.1.5ColumnspvRuLpRelayNcread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.4NodespvRuLpAlarm
1.3.6.1.4.1.6626.6000.4.12.4.1TablespvRuLpAlarmGlobalTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.4.1.1RowspvRuLpAlarmGlobalEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.4.1.1.1ColumnspvRuLpAlarmGlobalCountread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.4.1.1.2ColumnspvRuLpAlarmMaxSeverityread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.12.4.1.1.3ColumnspvRuLpReachableread-onlycurrentmodule reachable or not.
1.3.6.1.4.1.6626.6000.4.12.4.2TablespvRuLpAlarmTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.4.2.1RowspvRuLpAlarmEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.4.2.1.1ColumnspvRuLpAlarmTypenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.12.4.2.1.2ColumnspvRuLpAlarmEnableread-writecurrentRULP alarm enable
1.3.6.1.4.1.6626.6000.4.12.4.2.1.3ColumnspvRuLpAlarmStateread-onlycurrentRULP alarm state
1.3.6.1.4.1.6626.6000.4.12.4.2.1.4ColumnspvRuLpAlarmSeverityread-writecurrentRULP alarm severity
1.3.6.1.4.1.6626.6000.4.12.4.2.1.5ColumnspvRuLpAlarmPolarityread-writecurrentRULP alarm polarity
1.3.6.1.4.1.6626.6000.4.12.4.2.1.6ColumnspvRuLpAlarmNameread-writecurrentRULP alarm name.
1.3.6.1.4.1.6626.6000.4.13NodespvDfe
1.3.6.1.4.1.6626.6000.4.13.1TablespvDfeTablenot-accessiblecurrentDFE table
1.3.6.1.4.1.6626.6000.4.13.1.1RowspvDfeEntrynot-accessiblecurrentDFE table entry
1.3.6.1.4.1.6626.6000.4.13.1.1.1ColumnspvDfeIndexnot-accessiblecurrentDFE index
1.3.6.1.4.1.6626.6000.4.13.1.1.2ColumnspvDfeTyperead-onlycurrentDFE type
1.3.6.1.4.1.6626.6000.4.13.1.1.3ColumnspvDfeModelread-onlycurrentDFE model
1.3.6.1.4.1.6626.6000.4.13.1.1.4ColumnspvDfeCommercialCoderead-onlycurrentDFE sale code
1.3.6.1.4.1.6626.6000.4.13.1.1.5ColumnspvDfeCommercialDescriptionread-onlycurrentDFE sale description
1.3.6.1.4.1.6626.6000.4.13.1.1.6ColumnspvDfeVersionread-onlycurrentDFE version
1.3.6.1.4.1.6626.6000.4.13.1.1.7ColumnspvDfeSerialNumberread-onlycurrentDFE serial number
1.3.6.1.4.1.6626.6000.4.13.1.1.8ColumnspvDfeProductionDateread-onlycurrentDFE production date
1.3.6.1.4.1.6626.6000.4.13.1.1.9ColumnspvDfeCommissionDateread-writecurrentDFE commissioning date
1.3.6.1.4.1.6626.6000.4.13.1.1.10ColumnspvDfeTemperatureread-onlycurrentDFE temperature in (C)
1.3.6.1.4.1.6626.6000.4.13.1.1.11ColumnspvDfePwrOutUlread-onlycurrentDFE power out ul (dBm)
1.3.6.1.4.1.6626.6000.4.13.1.1.12ColumnspvDfePwrOutDlread-onlycurrentDFE power out dl(dBm)
1.3.6.1.4.1.6626.6000.4.13.1.1.13ColumnspvDfePwrInUlread-onlycurrentDFE power in ul(dBm)
1.3.6.1.4.1.6626.6000.4.13.1.1.14ColumnspvDfePwrInDlread-onlycurrentDFE power in dl(dBm)
1.3.6.1.4.1.6626.6000.4.13.1.1.15ColumnspvDfeTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.13.1.1.16ColumnspvDfePresetMenuread-writecurrentDFE preset menu
1.3.6.1.4.1.6626.6000.4.13.1.1.17ColumnspvDfeNameread-writecurrentDFE name
1.3.6.1.4.1.6626.6000.4.13.1.1.18ColumnspvDfeBandTyperead-writecurrentDFE Band Type: narrow or wide.
1.3.6.1.4.1.6626.6000.4.13.1.1.19ColumnspvDfeSelectivityread-writecurrentWide band limit.
1.3.6.1.4.1.6626.6000.4.13.1.1.20ColumnspvDfeUserModuleAttUlread-onlycurrentDFE User Module Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.13.1.1.21ColumnspvDfeUserModuleAttDlread-onlycurrentDFE User Module Downlink Attenuation
1.3.6.1.4.1.6626.6000.4.13.1.1.30ColumnspvDfeSelfOscillatorStateread-onlycurrentself oscillator state: 0=Ok,1=Lowered Gain,2=RF Off,3=ALC On
1.3.6.1.4.1.6626.6000.4.13.1.1.31ColumnspvDfeSelfOscillatorEnableread-writecurrentself oscillator enable
1.3.6.1.4.1.6626.6000.4.13.1.1.32ColumnspvDfeSelfOscillatorClearread-writecurrentself oscillator clear command
1.3.6.1.4.1.6626.6000.4.13.1.1.33ColumnspvDfeVendorIdread-writecurrentStop frequency used in test mode.
1.3.6.1.4.1.6626.6000.4.13.1.1.34ColumnspvDfeSelfOscillatorRestoreread-writecurrentself oscillator restore command
1.3.6.1.4.1.6626.6000.4.13.1.1.35ColumnspvDfeUserModuleAttPrevUlread-onlycurrentDFE User Module Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.13.1.1.36ColumnspvDfeUserModuleAttPrevDlread-onlycurrentDFE User Module Downlink Attenuation
1.3.6.1.4.1.6626.6000.4.13.1.1.37ColumnspvDfeDataTimestampread-onlycurrentDFE production date
1.3.6.1.4.1.6626.6000.4.13.1.1.38ColumnspvDfeDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.13.1.1.39ColumnspvDfeDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.13.2TablespvDfeChTablenot-accessiblecurrentDFE receivers table
1.3.6.1.4.1.6626.6000.4.13.2.1RowspvDfeChEntrynot-accessiblecurrentDFE receivers table entry
1.3.6.1.4.1.6626.6000.4.13.2.1.1ColumnspvDfeChIndexnot-accessiblecurrentDFE receiver index
1.3.6.1.4.1.6626.6000.4.13.2.1.2ColumnspvDfeEnableUlChread-writecurrentDFE Ul enable
1.3.6.1.4.1.6626.6000.4.13.2.1.3ColumnspvDfeEnableDlChread-writecurrentDFE Dl enable
1.3.6.1.4.1.6626.6000.4.13.2.1.4ColumnspvDfePwrUlChread-onlycurrentDFE power (dBm)
1.3.6.1.4.1.6626.6000.4.13.2.1.5ColumnspvDfePwrDlChread-onlycurrentDFE power (dBm)
1.3.6.1.4.1.6626.6000.4.13.2.1.6ColumnspvDfeAttUlChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.13.2.1.7ColumnspvDfeAttDlChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.13.2.1.8ColumnspvDfeFrqChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.13.2.1.9ColumnspvDfeBwtChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.13.2.1.10ColumnspvDfeFilterIdChread-onlycurrentFilter ID.
1.3.6.1.4.1.6626.6000.4.13.3NodespvDfeAlarm
1.3.6.1.4.1.6626.6000.4.13.3.1TablespvDfeAlarmGlobalTablenot-accessiblecurrentDFE alarms global table
1.3.6.1.4.1.6626.6000.4.13.3.1.1RowspvDfeAlarmGlobalEntrynot-accessiblecurrentDFE alarms global table entry
1.3.6.1.4.1.6626.6000.4.13.3.1.1.1ColumnspvDfeAlarmGlobalCountread-onlycurrentDFE alarms global count
1.3.6.1.4.1.6626.6000.4.13.3.1.1.2ColumnspvDfeAlarmMaxSeverityread-onlycurrentDFE alarms max severity
1.3.6.1.4.1.6626.6000.4.13.3.1.1.3ColumnspvDfeReachableread-onlycurrentDFE reachable
1.3.6.1.4.1.6626.6000.4.13.3.2TablespvDfeAlarmTablenot-accessiblecurrentDFE alarms table
1.3.6.1.4.1.6626.6000.4.13.3.2.1RowspvDfeAlarmEntrynot-accessiblecurrentDFE alarms table entry
1.3.6.1.4.1.6626.6000.4.13.3.2.1.1ColumnspvDfeAlarmTypenot-accessiblecurrentDFE alarm type
1.3.6.1.4.1.6626.6000.4.13.3.2.1.2ColumnspvDfeAlarmEnableread-writecurrentDFE alarm enable
1.3.6.1.4.1.6626.6000.4.13.3.2.1.3ColumnspvDfeAlarmStateread-onlycurrentDFE alarm state
1.3.6.1.4.1.6626.6000.4.13.3.2.1.4ColumnspvDfeAlarmSeverityread-onlycurrentDFE alarm severity
1.3.6.1.4.1.6626.6000.4.13.3.2.1.5ColumnspvDfeAlarmPolarityread-onlycurrentDFE alarm Polarity
1.3.6.1.4.1.6626.6000.4.13.3.2.1.6ColumnspvDfeAlarmNameread-onlycurrentDFE alarm name
1.3.6.1.4.1.6626.6000.4.14NodespvAlarmBoard
1.3.6.1.4.1.6626.6000.4.14.1TablespvAlarmBoardTablenot-accessiblecurrentTBD
1.3.6.1.4.1.6626.6000.4.14.1.1RowspvAlarmBoardEntrynot-accessiblecurrentTBD
1.3.6.1.4.1.6626.6000.4.14.1.1.1ColumnspvAlarmBoardIndexnot-accessiblecurrentAlarm Board slot index (1-12)
1.3.6.1.4.1.6626.6000.4.14.1.1.2ColumnspvAlarmBoardTyperead-onlycurrentAlarms Board type
1.3.6.1.4.1.6626.6000.4.14.1.1.3ColumnspvAlarmBoardModelread-onlycurrentAlarms Board model
1.3.6.1.4.1.6626.6000.4.14.1.1.4ColumnspvAlarmBoardCommercialCoderead-onlycurrentAlarms Board sale code
1.3.6.1.4.1.6626.6000.4.14.1.1.5ColumnspvAlarmBoardCommercialDescriptionread-onlycurrentAlarms Board sale description
1.3.6.1.4.1.6626.6000.4.14.1.1.6ColumnspvAlarmBoardVersionread-onlycurrentAlarms Board version
1.3.6.1.4.1.6626.6000.4.14.1.1.7ColumnspvAlarmBoardSerialNumberread-onlycurrentAlarms Board serial number
1.3.6.1.4.1.6626.6000.4.14.1.1.8ColumnspvAlarmBoardProductionDateread-onlycurrentAlarms Board production date
1.3.6.1.4.1.6626.6000.4.14.1.1.9ColumnspvAlarmBoardCommissionDateread-writecurrentAlarms Board commissioning date
1.3.6.1.4.1.6626.6000.4.14.1.1.10ColumnspvAlarmBoardTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.14.1.1.11ColumnspvAlarmBoardVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.14.1.1.12ColumnspvAlarmBoardTemperatureread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.14.1.1.13ColumnspvAlarmBoardCur28vread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.14.1.1.14ColumnspvAlarmBoardDataTimestampread-onlycurrentAlarms Board production date
1.3.6.1.4.1.6626.6000.4.14.1.1.15ColumnspvAlarmBoardDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.14.1.1.16ColumnspvAlarmBoardDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.14.2TablespvAlarmBoardRelayTablenot-accessiblecurrentAlarmBoard relays table
1.3.6.1.4.1.6626.6000.4.14.2.1RowspvAlarmBoardRelayEntrynot-accessiblecurrentAlarmBoard relay table entry
1.3.6.1.4.1.6626.6000.4.14.2.1.1ColumnspvAlarmBoardRelayIndexnot-accessiblecurrentindex of relay
1.3.6.1.4.1.6626.6000.4.14.2.1.2ColumnspvAlarmBoardRelayStateread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.14.2.1.3ColumnspvAlarmBoardRelayNameread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.14.2.1.4ColumnspvAlarmBoardRelayPolicyread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.14.2.1.5ColumnspvAlarmBoardRelayNcread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.14.3NodespvAlarmBoardAlarm
1.3.6.1.4.1.6626.6000.4.14.3.1TablespvAlarmBoardAlarmGlobalTablenot-accessiblecurrentAlarms Board alarms global table
1.3.6.1.4.1.6626.6000.4.14.3.1.1RowspvAlarmBoardAlarmGlobalEntrynot-accessiblecurrentAlarms Board alarms global table entry
1.3.6.1.4.1.6626.6000.4.14.3.1.1.1ColumnspvAlarmBoardAlarmGlobalCountread-onlycurrentAlarms Board alarms global count
1.3.6.1.4.1.6626.6000.4.14.3.1.1.2ColumnspvAlarmBoardAlarmMaxSeverityread-onlycurrentAlarms Board alarms max severity
1.3.6.1.4.1.6626.6000.4.14.3.1.1.3ColumnspvAlarmBoardReachableread-onlycurrentAlarms Board module availability
1.3.6.1.4.1.6626.6000.4.14.3.2TablespvAlarmBoardAlarmTablenot-accessiblecurrentAlarms Board alarm table
1.3.6.1.4.1.6626.6000.4.14.3.2.1RowspvAlarmBoardAlarmEntrynot-accessiblecurrentAlarms Board alarm table entry
1.3.6.1.4.1.6626.6000.4.14.3.2.1.1ColumnspvAlarmBoardAlarmTypenot-accessiblecurrentAlarms Board alarm type
1.3.6.1.4.1.6626.6000.4.14.3.2.1.2ColumnspvAlarmBoardAlarmEnableread-writecurrentAlarms Board alarm enable
1.3.6.1.4.1.6626.6000.4.14.3.2.1.3ColumnspvAlarmBoardAlarmStateread-onlycurrentAlarms Board alarm current state
1.3.6.1.4.1.6626.6000.4.14.3.2.1.4ColumnspvAlarmBoardAlarmSeverityread-writecurrentAlarms Board alarm severity
1.3.6.1.4.1.6626.6000.4.14.3.2.1.5ColumnspvAlarmBoardAlarmPolarityread-writecurrentAlarms Board external alarm polarity
1.3.6.1.4.1.6626.6000.4.14.3.2.1.6ColumnspvAlarmBoardAlarmNameread-writecurrentAlarms Board alarm name
1.3.6.1.4.1.6626.6000.4.15NodespvSfe
1.3.6.1.4.1.6626.6000.4.15.1TablespvSfeTablenot-accessiblecurrentSFE table
1.3.6.1.4.1.6626.6000.4.15.1.1RowspvSfeEntrynot-accessiblecurrentSFE table entry
1.3.6.1.4.1.6626.6000.4.15.1.1.1ColumnspvSfeIndexnot-accessiblecurrentSFE index
1.3.6.1.4.1.6626.6000.4.15.1.1.2ColumnspvSfeTyperead-onlycurrentSFE type
1.3.6.1.4.1.6626.6000.4.15.1.1.3ColumnspvSfeModelread-onlycurrentSFE model
1.3.6.1.4.1.6626.6000.4.15.1.1.4ColumnspvSfeCommercialCoderead-onlycurrentSFE sale code
1.3.6.1.4.1.6626.6000.4.15.1.1.5ColumnspvSfeCommercialDescriptionread-onlycurrentSFE sale description
1.3.6.1.4.1.6626.6000.4.15.1.1.6ColumnspvSfeVersionread-onlycurrentSFE version
1.3.6.1.4.1.6626.6000.4.15.1.1.7ColumnspvSfeSerialNumberread-onlycurrentSFE serial number
1.3.6.1.4.1.6626.6000.4.15.1.1.8ColumnspvSfeProductionDateread-onlycurrentSFE production date
1.3.6.1.4.1.6626.6000.4.15.1.1.9ColumnspvSfeCommissionDateread-writecurrentSFE commissioning date
1.3.6.1.4.1.6626.6000.4.15.1.1.10ColumnspvSfeTemperatureread-onlycurrentSFE temperature in (C)
1.3.6.1.4.1.6626.6000.4.15.1.1.11ColumnspvSfePwrread-onlycurrentSFE power (dBm)
1.3.6.1.4.1.6626.6000.4.15.1.1.12ColumnspvSfeEnableMainUlread-writecurrentSFE enable
1.3.6.1.4.1.6626.6000.4.15.1.1.13ColumnspvSfeEnableMainDlread-writecurrentSFE enable
1.3.6.1.4.1.6626.6000.4.15.1.1.14ColumnspvSfeEnableAuxUlread-writecurrentSFE enable
1.3.6.1.4.1.6626.6000.4.15.1.1.15ColumnspvSfeEnableAuxDlread-writecurrentSFE enable
1.3.6.1.4.1.6626.6000.4.15.1.1.16ColumnspvSfeAttMainUlread-writecurrentSFE attenuation (dB)
1.3.6.1.4.1.6626.6000.4.15.1.1.17ColumnspvSfeAttMainDlread-writecurrentSFE attenuation (dB)
1.3.6.1.4.1.6626.6000.4.15.1.1.18ColumnspvSfeAttAuxUlread-writecurrentSFE attenuation (dB)
1.3.6.1.4.1.6626.6000.4.15.1.1.19ColumnspvSfeAttAuxDlread-writecurrentSFE attenuation (dB)
1.3.6.1.4.1.6626.6000.4.15.1.1.20ColumnspvSfeTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.15.1.1.21ColumnspvSfePresetMenuread-writecurrentSFE preset menu
1.3.6.1.4.1.6626.6000.4.15.1.1.22ColumnspvSfeVendorIdread-writecurrentSFE preset menu
1.3.6.1.4.1.6626.6000.4.15.1.1.23ColumnspvSfeDataTimestampread-onlycurrentSFE production date
1.3.6.1.4.1.6626.6000.4.15.1.1.24ColumnspvSfeDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.15.1.1.25ColumnspvSfeDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.15.2NodespvSfeAlarm
1.3.6.1.4.1.6626.6000.4.15.2.1TablespvSfeAlarmGlobalTablenot-accessiblecurrentSFE alarms global table
1.3.6.1.4.1.6626.6000.4.15.2.1.1RowspvSfeAlarmGlobalEntrynot-accessiblecurrentSFE alarms global table entry
1.3.6.1.4.1.6626.6000.4.15.2.1.1.1ColumnspvSfeAlarmGlobalCountread-onlycurrentSFE alarms global count
1.3.6.1.4.1.6626.6000.4.15.2.1.1.2ColumnspvSfeAlarmMaxSeverityread-onlycurrentSFE alarms max severity
1.3.6.1.4.1.6626.6000.4.15.2.1.1.3ColumnspvSfeReachableread-onlycurrentSFE reachable
1.3.6.1.4.1.6626.6000.4.15.2.2TablespvSfeAlarmTablenot-accessiblecurrentSFE alarms table
1.3.6.1.4.1.6626.6000.4.15.2.2.1RowspvSfeAlarmEntrynot-accessiblecurrentSFE alarms table entry
1.3.6.1.4.1.6626.6000.4.15.2.2.1.1ColumnspvSfeAlarmTypenot-accessiblecurrentSFE alarm type
1.3.6.1.4.1.6626.6000.4.15.2.2.1.2ColumnspvSfeAlarmEnableread-writecurrentSFE alarm enable
1.3.6.1.4.1.6626.6000.4.15.2.2.1.3ColumnspvSfeAlarmStateread-onlycurrentSFE alarm state
1.3.6.1.4.1.6626.6000.4.15.2.2.1.4ColumnspvSfeAlarmSeverityread-onlycurrentSFE alarm severity
1.3.6.1.4.1.6626.6000.4.15.2.2.1.5ColumnspvSfeAlarmPolarityread-onlycurrentSFE alarm polarity
1.3.6.1.4.1.6626.6000.4.15.2.2.1.6ColumnspvSfeAlarmNameread-onlycurrentSFE alarm name
1.3.6.1.4.1.6626.6000.4.16NodespvRuLp5b
1.3.6.1.4.1.6626.6000.4.16.1TablespvRuLp5bTablenot-accessiblecurrent
1.3.6.1.4.1.6626.6000.4.16.1.1RowspvRuLp5bEntrynot-accessiblecurrent
1.3.6.1.4.1.6626.6000.4.16.1.1.1ColumnspvRuLp5bIndexnot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.2ColumnspvRuLp5bTyperead-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.3ColumnspvRuLp5bModelread-onlycurrent
1.3.6.1.4.1.6626.6000.4.16.1.1.4ColumnspvRuLp5bCommercialCoderead-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.5ColumnspvRuLp5bCommercialDescriptionread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.6ColumnspvRuLp5bVersionread-onlycurrent
1.3.6.1.4.1.6626.6000.4.16.1.1.7ColumnspvRuLp5bNameread-writecurrent
1.3.6.1.4.1.6626.6000.4.16.1.1.8ColumnspvRuLp5bDescriptionread-writecurrent
1.3.6.1.4.1.6626.6000.4.16.1.1.9ColumnspvRuLp5bLocationLatituderead-writecurrent
1.3.6.1.4.1.6626.6000.4.16.1.1.10ColumnspvRuLp5bLocationLongituderead-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.11ColumnspvRuLp5bSerialNumberread-onlycurrent
1.3.6.1.4.1.6626.6000.4.16.1.1.12ColumnspvRuLp5bProductionDateread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.13ColumnspvRuLp5bCommissionDateread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.14ColumnspvRuLp5bTemperatureread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.15ColumnspvRuLp5bPsuVoutread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.16ColumnspvRuLp5bPwrTxread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.17ColumnspvRuLp5bPwrRxread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.18ColumnspvRuLp5bTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.16.1.1.19ColumnspvRuLp5bVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.16.1.1.20ColumnspvRuLp5bFiberLossread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.16.1.1.21ColumnspvRuLp5bDataTimestampread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.1.1.22ColumnspvRuLp5bDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.16.1.1.23ColumnspvRuLp5bDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.16.1.1.24ColumnspvRuLp5bCwCommandOnread-writecurrentContinous Wave calibration
1.3.6.1.4.1.6626.6000.4.16.1.1.25ColumnspvRuLp5bCwSelectorread-writecurrentContinous Wave Frequency
1.3.6.1.4.1.6626.6000.4.16.2TablespvRuLp5bChTablenot-accessiblecurrentRULP5B channels table
1.3.6.1.4.1.6626.6000.4.16.2.1RowspvRuLp5bChEntrynot-accessiblecurrentRULP5B channels table entry
1.3.6.1.4.1.6626.6000.4.16.2.1.1ColumnspvRuLp5bChIndexnot-accessiblecurrentindex of the channel
1.3.6.1.4.1.6626.6000.4.16.2.1.2ColumnspvRuLp5bAttUlChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.2.1.3ColumnspvRuLp5bAttDlChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.2.1.4ColumnspvRuLp5bRfEnableChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.2.1.5ColumnspvRuLp5bPwrUlChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.2.1.6ColumnspvRuLp5bPwrDlChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.3TablespvRuLp5bRelayTablenot-accessiblecurrentRULP5B relays table
1.3.6.1.4.1.6626.6000.4.16.3.1RowspvRuLp5bRelayEntrynot-accessiblecurrentRULP5B relay table entry
1.3.6.1.4.1.6626.6000.4.16.3.1.1ColumnspvRuLp5bRelayIndexnot-accessiblecurrentindex of relay
1.3.6.1.4.1.6626.6000.4.16.3.1.2ColumnspvRuLp5bRelayStateread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.3.1.3ColumnspvRuLp5bRelayNameread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.3.1.4ColumnspvRuLp5bRelayPolicyread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.3.1.5ColumnspvRuLp5bRelayNcread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4NodespvRuLp5bAlarm
1.3.6.1.4.1.6626.6000.4.16.4.1TablespvRuLp5bAlarmGlobalTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.1.1RowspvRuLp5bAlarmGlobalEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.1.1.1ColumnspvRuLp5bAlarmGlobalCountread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.1.1.2ColumnspvRuLp5bAlarmMaxSeverityread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.1.1.3ColumnspvRuLp5bReachableread-onlycurrentmodule reachable or not.
1.3.6.1.4.1.6626.6000.4.16.4.2TablespvRuLp5bAlarmTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.2.1RowspvRuLp5bAlarmEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.2.1.1ColumnspvRuLp5bAlarmTypenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.2.1.2ColumnspvRuLp5bAlarmEnableread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.2.1.3ColumnspvRuLp5bAlarmStateread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.2.1.4ColumnspvRuLp5bAlarmSeverityread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.2.1.5ColumnspvRuLp5bAlarmPolarityread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.16.4.2.1.6ColumnspvRuLp5bAlarmNameread-writecurrentalarm name.
1.3.6.1.4.1.6626.6000.4.17NodespvDfeFpga
1.3.6.1.4.1.6626.6000.4.17.1TablespvDfeFpgaTablenot-accessiblecurrentDFE-FPGA table
1.3.6.1.4.1.6626.6000.4.17.1.1RowspvDfeFpgaEntrynot-accessiblecurrentDFE-FPGA table entry
1.3.6.1.4.1.6626.6000.4.17.1.1.1ColumnspvDfeFpgaIndexnot-accessiblecurrentDFE-FPGA index
1.3.6.1.4.1.6626.6000.4.17.1.1.2ColumnspvDfeFpgaTyperead-onlycurrentDFE-FPGA type
1.3.6.1.4.1.6626.6000.4.17.1.1.3ColumnspvDfeFpgaModelread-onlycurrentDFE-FPGA model
1.3.6.1.4.1.6626.6000.4.17.1.1.4ColumnspvDfeFpgaCommercialCoderead-onlycurrentDFE-FPGA sale code
1.3.6.1.4.1.6626.6000.4.17.1.1.5ColumnspvDfeFpgaCommercialDescriptionread-onlycurrentDFE-FPGA sale description
1.3.6.1.4.1.6626.6000.4.17.1.1.6ColumnspvDfeFpgaVersionread-onlycurrentDFE-FPGA version
1.3.6.1.4.1.6626.6000.4.17.1.1.7ColumnspvDfeFpgaSerialNumberread-onlycurrentDFE-FPGA serial number
1.3.6.1.4.1.6626.6000.4.17.1.1.8ColumnspvDfeFpgaProductionDateread-onlycurrentDFE-FPGA production date
1.3.6.1.4.1.6626.6000.4.17.1.1.9ColumnspvDfeFpgaCommissionDateread-writecurrentDFE-FPGA commissioning date
1.3.6.1.4.1.6626.6000.4.17.1.1.10ColumnspvDfeFpgaVendorIdread-onlycurrentself oscillator clear command
1.3.6.1.4.1.6626.6000.4.17.1.1.11ColumnspvDfeFpgaTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.17.1.1.12ColumnspvDfeFpgaTemperatureread-onlycurrentDFE-FPGA temperature in (C)
1.3.6.1.4.1.6626.6000.4.17.1.1.13ColumnspvDfeFpgaPwrOutread-onlycurrentDFE-FPGA power out (dBm)
1.3.6.1.4.1.6626.6000.4.17.1.1.14ColumnspvDfeFpgaPwrInread-onlycurrentDFE-FPGA power in (dBm)
1.3.6.1.4.1.6626.6000.4.17.1.1.15ColumnspvDfeFpgaPresetMenuread-writecurrentDFE-FPGA preset menu
1.3.6.1.4.1.6626.6000.4.17.1.1.16ColumnspvDfeFpgaNameread-writecurrentDFE-FPGA name
1.3.6.1.4.1.6626.6000.4.17.1.1.17ColumnspvDfeFpgaUserModuleAttread-onlycurrentDFE-FPGA User Module Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.17.1.1.18ColumnspvDfeFpgaUserModuleAttPrevread-onlycurrentDFE-FPGA User Module Uplink Attenuation previous
1.3.6.1.4.1.6626.6000.4.17.1.1.27ColumnspvDfeFpgaSelfOscillatorStateread-onlycurrentself oscillator state: 0=Ok,1=Lowered Gain,2=RF Off,3=ALC On
1.3.6.1.4.1.6626.6000.4.17.1.1.28ColumnspvDfeFpgaSelfOscillatorEnableread-writecurrentself oscillator enable
1.3.6.1.4.1.6626.6000.4.17.1.1.29ColumnspvDfeFpgaSelfOscillatorClearread-writecurrentself oscillator clear command
1.3.6.1.4.1.6626.6000.4.17.1.1.30ColumnspvDfeFpgaSelfOscillatorRestoreread-writecurrentself oscillator restore command
1.3.6.1.4.1.6626.6000.4.17.1.1.31ColumnspvDfeFpgaChannelConfigread-onlycurrentChannel configuration
1.3.6.1.4.1.6626.6000.4.17.1.1.32ColumnspvDfeFpgaDataTimestampread-onlycurrentDFE-FPGA production date
1.3.6.1.4.1.6626.6000.4.17.1.1.33ColumnspvDfeFpgaDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.17.1.1.34ColumnspvDfeFpgaDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.17.1.1.35ColumnspvDfeFpgaRfOutEnableread-writecurrentself oscillator enable
1.3.6.1.4.1.6626.6000.4.17.2TablespvDfeFpgaChTablenot-accessiblecurrentDFE-FPGA receivers table
1.3.6.1.4.1.6626.6000.4.17.2.1RowspvDfeFpgaChEntrynot-accessiblecurrentDFE-FPGA receivers table entry
1.3.6.1.4.1.6626.6000.4.17.2.1.1ColumnspvDfeFpgaChIndexnot-accessiblecurrentDFE-FPGA receiver index
1.3.6.1.4.1.6626.6000.4.17.2.1.2ColumnspvDfeFpgaEnableChread-writecurrentDFE-FPGA Ul enable
1.3.6.1.4.1.6626.6000.4.17.2.1.3ColumnspvDfeFpgaPwrChread-onlycurrentDFE-FPGA power (dBm)
1.3.6.1.4.1.6626.6000.4.17.2.1.4ColumnspvDfeFpgaAttChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.17.2.1.5ColumnspvDfeFpgaFrqChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.17.2.1.6ColumnspvDfeFpgaBwtChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.17.2.1.7ColumnspvDfeFpgaThrPwrMinChread-writecurrentThreshold Pwr Min (dBm).
1.3.6.1.4.1.6626.6000.4.17.2.1.8ColumnspvDfeFpgaThrAlcChread-writecurrentThreshold ALC (dBm).
1.3.6.1.4.1.6626.6000.4.17.2.1.9ColumnspvDfeFpgaPwrSwitchChread-writecurrentDFE-FPGA peak - rms
1.3.6.1.4.1.6626.6000.4.17.3NodespvDfeFpgaAlarm
1.3.6.1.4.1.6626.6000.4.17.3.1TablespvDfeFpgaAlarmGlobalTablenot-accessiblecurrentDFE-FPGA alarms global table
1.3.6.1.4.1.6626.6000.4.17.3.1.1RowspvDfeFpgaAlarmGlobalEntrynot-accessiblecurrentDFE-FPGA alarms global table entry
1.3.6.1.4.1.6626.6000.4.17.3.1.1.1ColumnspvDfeFpgaAlarmGlobalCountread-onlycurrentDFE-FPGA alarms global count
1.3.6.1.4.1.6626.6000.4.17.3.1.1.2ColumnspvDfeFpgaAlarmMaxSeverityread-onlycurrentDFE-FPGA alarms max severity
1.3.6.1.4.1.6626.6000.4.17.3.1.1.3ColumnspvDfeFpgaReachableread-onlycurrentDFE-FPGA reachable
1.3.6.1.4.1.6626.6000.4.17.3.2TablespvDfeFpgaAlarmTablenot-accessiblecurrentDFE-FPGA alarms table
1.3.6.1.4.1.6626.6000.4.17.3.2.1RowspvDfeFpgaAlarmEntrynot-accessiblecurrentDFE-FPGA alarms table entry
1.3.6.1.4.1.6626.6000.4.17.3.2.1.1ColumnspvDfeFpgaAlarmTypenot-accessiblecurrentDFE-FPGA alarm type
1.3.6.1.4.1.6626.6000.4.17.3.2.1.2ColumnspvDfeFpgaAlarmEnableread-writecurrentDFE-FPGA alarm enable
1.3.6.1.4.1.6626.6000.4.17.3.2.1.3ColumnspvDfeFpgaAlarmStateread-onlycurrentDFE-FPGA alarm state
1.3.6.1.4.1.6626.6000.4.17.3.2.1.4ColumnspvDfeFpgaAlarmSeverityread-onlycurrentDFE-FPGA alarm severity
1.3.6.1.4.1.6626.6000.4.17.3.2.1.5ColumnspvDfeFpgaAlarmPolarityread-onlycurrentDFE-FPGA alarm Polarity
1.3.6.1.4.1.6626.6000.4.17.3.2.1.6ColumnspvDfeFpgaAlarmNameread-onlycurrentDFE-FPGA alarm name
1.3.6.1.4.1.6626.6000.4.18NodespvFan
1.3.6.1.4.1.6626.6000.4.18.1TablespvFanTablenot-accessiblecurrentTFAN table
1.3.6.1.4.1.6626.6000.4.18.1.1RowspvFanEntrynot-accessiblecurrentTFAN table entry
1.3.6.1.4.1.6626.6000.4.18.1.1.1ColumnspvFanIndexnot-accessiblecurrentTFAN index
1.3.6.1.4.1.6626.6000.4.18.1.1.2ColumnspvFanTyperead-onlycurrentTFAN type
1.3.6.1.4.1.6626.6000.4.18.1.1.3ColumnspvFanModelread-onlycurrentTFAN model
1.3.6.1.4.1.6626.6000.4.18.1.1.4ColumnspvFanCommercialCoderead-onlycurrentTFAN sale code
1.3.6.1.4.1.6626.6000.4.18.1.1.5ColumnspvFanCommercialDescriptionread-onlycurrentTFAN sale description
1.3.6.1.4.1.6626.6000.4.18.1.1.6ColumnspvFanVersionread-onlycurrentTFAN version
1.3.6.1.4.1.6626.6000.4.18.1.1.7ColumnspvFanSerialNumberread-onlycurrentTFAN serial number
1.3.6.1.4.1.6626.6000.4.18.1.1.8ColumnspvFanProductionDateread-onlycurrentTFAN production date
1.3.6.1.4.1.6626.6000.4.18.1.1.9ColumnspvFanCommissionDateread-writecurrentTFAN commissioning date
1.3.6.1.4.1.6626.6000.4.18.1.1.10ColumnspvFanTemperatureread-onlycurrentTFAN temperature in (C)
1.3.6.1.4.1.6626.6000.4.18.1.1.11ColumnspvFanTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.18.1.1.12ColumnspvFanVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.18.1.1.13ColumnspvFanDataTimestampread-onlycurrentTFAN production date
1.3.6.1.4.1.6626.6000.4.18.1.1.14ColumnspvFanDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.18.1.1.15ColumnspvFanDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.18.2NodespvFanAlarm
1.3.6.1.4.1.6626.6000.4.18.2.1TablespvFanAlarmGlobalTablenot-accessiblecurrentTFAN alarms global table
1.3.6.1.4.1.6626.6000.4.18.2.1.1RowspvFanAlarmGlobalEntrynot-accessiblecurrentTFAN alarms global table entry
1.3.6.1.4.1.6626.6000.4.18.2.1.1.1ColumnspvFanAlarmGlobalCountread-onlycurrentTFAN alarms global count
1.3.6.1.4.1.6626.6000.4.18.2.1.1.2ColumnspvFanAlarmMaxSeverityread-onlycurrentTFAN alarms max severity
1.3.6.1.4.1.6626.6000.4.18.2.1.1.3ColumnspvFanReachableread-onlycurrentTFAN reachable
1.3.6.1.4.1.6626.6000.4.18.2.2TablespvFanAlarmTablenot-accessiblecurrentTFAN alarms table
1.3.6.1.4.1.6626.6000.4.18.2.2.1RowspvFanAlarmEntrynot-accessiblecurrentTFAN alarms table entry
1.3.6.1.4.1.6626.6000.4.18.2.2.1.1ColumnspvFanAlarmTypenot-accessiblecurrentTFAN alarm type
1.3.6.1.4.1.6626.6000.4.18.2.2.1.2ColumnspvFanAlarmEnableread-writecurrentTFAN alarm enable
1.3.6.1.4.1.6626.6000.4.18.2.2.1.3ColumnspvFanAlarmStateread-onlycurrentTFAN alarm state
1.3.6.1.4.1.6626.6000.4.18.2.2.1.4ColumnspvFanAlarmSeverityread-onlycurrentTFAN alarm severity
1.3.6.1.4.1.6626.6000.4.18.2.2.1.5ColumnspvFanAlarmPolarityread-onlycurrentTFAN alarm polarity
1.3.6.1.4.1.6626.6000.4.18.2.2.1.6ColumnspvFanAlarmNameread-onlycurrentTFAN alarm name
1.3.6.1.4.1.6626.6000.4.18.3TablespvFanFanTablenot-accessiblecurrentFan fan table
1.3.6.1.4.1.6626.6000.4.18.3.1RowspvFanFanEntrynot-accessiblecurrentRU-SPV fan table entry
1.3.6.1.4.1.6626.6000.4.18.3.1.1ColumnspvFanFanIndexnot-accessiblecurrentRU-SPV fan table index
1.3.6.1.4.1.6626.6000.4.18.3.1.2ColumnspvFanFanSpeedReadread-onlycurrentRU-SPV fan speed read in rpm
1.3.6.1.4.1.6626.6000.4.18.3.1.3ColumnspvFanFanSpeedPercentageread-onlycurrentRU-SPV fan speed read in rpm
1.3.6.1.4.1.6626.6000.4.19NodespvPoi
1.3.6.1.4.1.6626.6000.4.19.1TablespvPoiTablenot-accessiblecurrentPOI table
1.3.6.1.4.1.6626.6000.4.19.1.1RowspvPoiEntrynot-accessiblecurrentPOI table entry
1.3.6.1.4.1.6626.6000.4.19.1.1.1ColumnspvPoiIndexnot-accessiblecurrentPOI index
1.3.6.1.4.1.6626.6000.4.19.1.1.2ColumnspvPoiTyperead-onlycurrentPOI type
1.3.6.1.4.1.6626.6000.4.19.1.1.3ColumnspvPoiModelread-onlycurrentPOI model
1.3.6.1.4.1.6626.6000.4.19.1.1.4ColumnspvPoiCommercialCoderead-onlycurrentPOI sale code
1.3.6.1.4.1.6626.6000.4.19.1.1.5ColumnspvPoiCommercialDescriptionread-onlycurrentPOI sale description
1.3.6.1.4.1.6626.6000.4.19.1.1.6ColumnspvPoiVersionread-onlycurrentPOI version
1.3.6.1.4.1.6626.6000.4.19.1.1.7ColumnspvPoiSerialNumberread-onlycurrentPOI serial number
1.3.6.1.4.1.6626.6000.4.19.1.1.8ColumnspvPoiProductionDateread-onlycurrentPOI production date
1.3.6.1.4.1.6626.6000.4.19.1.1.9ColumnspvPoiCommissionDateread-writecurrentPOI commissioning date
1.3.6.1.4.1.6626.6000.4.19.1.1.10ColumnspvPoiTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.19.1.1.11ColumnspvPoiTemperatureread-onlycurrentPOI temperature in (C)
1.3.6.1.4.1.6626.6000.4.19.1.1.12ColumnspvPoiAttMeccDlread-writecurrentPOI attenuation (dB)
1.3.6.1.4.1.6626.6000.4.19.1.1.13ColumnspvPoiAttDlread-writecurrentPOI attenuation (dB)
1.3.6.1.4.1.6626.6000.4.19.1.1.14ColumnspvPoiAttUlCh1read-writecurrentPOI attenuation (dB)
1.3.6.1.4.1.6626.6000.4.19.1.1.15ColumnspvPoiAttUlCh2read-writecurrentPOI attenuation (dB)
1.3.6.1.4.1.6626.6000.4.19.1.1.16ColumnspvPoiPeakPwrread-onlycurrentPOI peak power (dBm)
1.3.6.1.4.1.6626.6000.4.19.1.1.17ColumnspvPoiRmsPwrread-onlycurrentPOI RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.19.1.1.18ColumnspvPoiPwrAlarmHysteresisread-writecurrentPOI power hysteresis
1.3.6.1.4.1.6626.6000.4.19.1.1.19ColumnspvPoiPwrLimiterread-writecurrentPOI power limiter menu
1.3.6.1.4.1.6626.6000.4.19.1.1.20ColumnspvPoiPwrLimiterModeread-writecurrentPOI power limiter mode menu
1.3.6.1.4.1.6626.6000.4.19.1.1.21ColumnspvPoiPresetMenuread-writecurrentPOI preset menu
1.3.6.1.4.1.6626.6000.4.19.1.1.22ColumnspvPoiThrMaxPeakPwrread-writecurrentPOI peak power (dBm)
1.3.6.1.4.1.6626.6000.4.19.1.1.23ColumnspvPoiThrMaxRmsPwrread-writecurrentPOI RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.19.1.1.24ColumnspvPoiNameread-writecurrentPOI Name, max 30 char
1.3.6.1.4.1.6626.6000.4.19.1.1.25ColumnspvPoiThrMinPeakPwrread-writecurrentPOI peak power (dBm)
1.3.6.1.4.1.6626.6000.4.19.1.1.26ColumnspvPoiThrMinRmsPwrread-writecurrentPOI RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.19.1.1.27ColumnspvPoiVendorIdread-writecurrentPOI Name, max 30 char
1.3.6.1.4.1.6626.6000.4.19.1.1.28ColumnspvPoiDataTimestampread-onlycurrentPOI production date
1.3.6.1.4.1.6626.6000.4.19.1.1.29ColumnspvPoiDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.19.1.1.30ColumnspvPoiDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.19.2NodespvPoiAlarm
1.3.6.1.4.1.6626.6000.4.19.2.1TablespvPoiAlarmGlobalTablenot-accessiblecurrentPOI alarms global table
1.3.6.1.4.1.6626.6000.4.19.2.1.1RowspvPoiAlarmGlobalEntrynot-accessiblecurrentPOI alarms global table entry
1.3.6.1.4.1.6626.6000.4.19.2.1.1.1ColumnspvPoiAlarmGlobalCountread-onlycurrentPOI alarms global count
1.3.6.1.4.1.6626.6000.4.19.2.1.1.2ColumnspvPoiAlarmMaxSeverityread-onlycurrentPOI alarms max severity
1.3.6.1.4.1.6626.6000.4.19.2.1.1.3ColumnspvPoiReachableread-onlycurrentPOI reachable
1.3.6.1.4.1.6626.6000.4.19.2.2TablespvPoiAlarmTablenot-accessiblecurrentPOI alarms table
1.3.6.1.4.1.6626.6000.4.19.2.2.1RowspvPoiAlarmEntrynot-accessiblecurrentPOI alarms table entry
1.3.6.1.4.1.6626.6000.4.19.2.2.1.1ColumnspvPoiAlarmTypenot-accessiblecurrentPOI alarm type
1.3.6.1.4.1.6626.6000.4.19.2.2.1.2ColumnspvPoiAlarmEnableread-writecurrentPOI alarm enable
1.3.6.1.4.1.6626.6000.4.19.2.2.1.3ColumnspvPoiAlarmStateread-onlycurrentPOI alarm state
1.3.6.1.4.1.6626.6000.4.19.2.2.1.4ColumnspvPoiAlarmSeverityread-onlycurrentPOI alarm severity
1.3.6.1.4.1.6626.6000.4.19.2.2.1.5ColumnspvPoiAlarmPolarityread-onlycurrentPOI alarm polarity
1.3.6.1.4.1.6626.6000.4.19.2.2.1.6ColumnspvPoiAlarmNameread-onlycurrentPOI alarm name
1.3.6.1.4.1.6626.6000.4.20NodespvComboSpv
1.3.6.1.4.1.6626.6000.4.20.1TablespvComboSpvTablenot-accessiblecurrentTBD
1.3.6.1.4.1.6626.6000.4.20.1.1RowspvComboSpvEntrynot-accessiblecurrentTBD
1.3.6.1.4.1.6626.6000.4.20.1.1.1ColumnspvComboSpvIndexnot-accessiblecurrentMini Repeater index in the system (1-16)
1.3.6.1.4.1.6626.6000.4.20.1.1.2ColumnspvComboSpvTyperead-onlycurrentMini Repeater type
1.3.6.1.4.1.6626.6000.4.20.1.1.3ColumnspvComboSpvModelread-onlycurrentMini Repeater model
1.3.6.1.4.1.6626.6000.4.20.1.1.4ColumnspvComboSpvCommercialCoderead-onlycurrentMini Repeater sale code
1.3.6.1.4.1.6626.6000.4.20.1.1.5ColumnspvComboSpvCommercialDescriptionread-onlycurrentMini Repeater sale description
1.3.6.1.4.1.6626.6000.4.20.1.1.6ColumnspvComboSpvVersionread-onlycurrentMini Repeater version
1.3.6.1.4.1.6626.6000.4.20.1.1.7ColumnspvComboSpvNameread-writecurrentMini Repeater name
1.3.6.1.4.1.6626.6000.4.20.1.1.8ColumnspvComboSpvDescriptionread-writecurrentMini Repeater description
1.3.6.1.4.1.6626.6000.4.20.1.1.9ColumnspvComboSpvLocationLatituderead-writecurrentMini Repeater latitude
1.3.6.1.4.1.6626.6000.4.20.1.1.10ColumnspvComboSpvLocationLongituderead-writecurrentMini Repeater longitude
1.3.6.1.4.1.6626.6000.4.20.1.1.11ColumnspvComboSpvSerialNumberread-onlycurrentMini Repeater serial number
1.3.6.1.4.1.6626.6000.4.20.1.1.12ColumnspvComboSpvProductionDateread-onlycurrentMini Repeater production date
1.3.6.1.4.1.6626.6000.4.20.1.1.13ColumnspvComboSpvCommissionDateread-writecurrentMini Repeater commissioning date
1.3.6.1.4.1.6626.6000.4.20.1.1.14ColumnspvComboSpvTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.20.1.1.15ColumnspvComboSpvVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.20.1.1.16ColumnspvComboSpvDataTimestampread-onlycurrentMini Repeater production date
1.3.6.1.4.1.6626.6000.4.20.1.1.17ColumnspvComboSpvDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.20.1.1.18ColumnspvComboSpvDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.20.1.1.19ColumnspvComboSpvTemperatureread-onlycurrentCombo SPV temperature in (C)
1.3.6.1.4.1.6626.6000.4.20.2TablespvComboSpvRelayTablenot-accessiblecurrentMini Repeater relays table
1.3.6.1.4.1.6626.6000.4.20.2.1RowspvComboSpvRelayEntrynot-accessiblecurrentMini Repeater relay table entry
1.3.6.1.4.1.6626.6000.4.20.2.1.1ColumnspvComboSpvRelayIndexnot-accessiblecurrentindex of relay
1.3.6.1.4.1.6626.6000.4.20.2.1.2ColumnspvComboSpvRelayStateread-writecurrentDescription.
1.3.6.1.4.1.6626.6000.4.20.2.1.3ColumnspvComboSpvRelayNameread-writecurrentDescription.
1.3.6.1.4.1.6626.6000.4.20.2.1.4ColumnspvComboSpvRelayPolicyread-writecurrentDescription.
1.3.6.1.4.1.6626.6000.4.20.2.1.5ColumnspvComboSpvRelayNcread-writecurrentDescription.
1.3.6.1.4.1.6626.6000.4.20.3NodespvComboSpvAlarm
1.3.6.1.4.1.6626.6000.4.20.3.1TablespvComboSpvAlarmGlobalTablenot-accessiblecurrentMini Repeater alarms global table
1.3.6.1.4.1.6626.6000.4.20.3.1.1RowspvComboSpvAlarmGlobalEntrynot-accessiblecurrentMini Repeater alarms global table entry
1.3.6.1.4.1.6626.6000.4.20.3.1.1.1ColumnspvComboSpvAlarmGlobalCountread-onlycurrentMini Repeater alarms global count
1.3.6.1.4.1.6626.6000.4.20.3.1.1.2ColumnspvComboSpvAlarmMaxSeverityread-onlycurrentMini Repeater alarms max severity
1.3.6.1.4.1.6626.6000.4.20.3.1.1.3ColumnspvComboSpvAlarmGlobalCountAllread-onlycurrentMini Repeater alarms global count
1.3.6.1.4.1.6626.6000.4.20.3.1.1.4ColumnspvComboSpvAlarmMaxSeverityAllread-onlycurrentMini Repeater alarms max severity
1.3.6.1.4.1.6626.6000.4.20.3.1.1.5ColumnspvComboSpvReachableread-onlycurrentMini Repeater reachable
1.3.6.1.4.1.6626.6000.4.20.3.2TablespvComboSpvAlarmTablenot-accessiblecurrentMini Repeater alarm table
1.3.6.1.4.1.6626.6000.4.20.3.2.1RowspvComboSpvAlarmEntrynot-accessiblecurrentMini Repeater alarm table entry
1.3.6.1.4.1.6626.6000.4.20.3.2.1.1ColumnspvComboSpvAlarmTypenot-accessiblecurrentCombo Spv alarm type
1.3.6.1.4.1.6626.6000.4.20.3.2.1.2ColumnspvComboSpvAlarmEnableread-writecurrentMini Repeater alarm enable
1.3.6.1.4.1.6626.6000.4.20.3.2.1.3ColumnspvComboSpvAlarmStateread-onlycurrentMini Repeater alarm current state
1.3.6.1.4.1.6626.6000.4.20.3.2.1.4ColumnspvComboSpvAlarmSeverityread-onlycurrentMini Repeater alarm severity
1.3.6.1.4.1.6626.6000.4.20.3.2.1.5ColumnspvComboSpvAlarmPolarityread-onlycurrentMini Repeater alarm polarity
1.3.6.1.4.1.6626.6000.4.20.3.2.1.6ColumnspvComboSpvAlarmNameread-onlycurrentMini Repeater alarm name
1.3.6.1.4.1.6626.6000.4.21NodespvComboDsp
1.3.6.1.4.1.6626.6000.4.21.1TablespvComboDspTablenot-accessiblecurrentDFE table
1.3.6.1.4.1.6626.6000.4.21.1.1RowspvComboDspEntrynot-accessiblecurrentDFE table entry
1.3.6.1.4.1.6626.6000.4.21.1.1.1ColumnspvComboDspIndexnot-accessiblecurrentCombo DSP index
1.3.6.1.4.1.6626.6000.4.21.1.1.2ColumnspvComboDspTyperead-onlycurrentCombo DSP type
1.3.6.1.4.1.6626.6000.4.21.1.1.3ColumnspvComboDspModelread-onlycurrentCombo DSP Model
1.3.6.1.4.1.6626.6000.4.21.1.1.4ColumnspvComboDspCommercialCoderead-onlycurrentCombo DSP Sale code
1.3.6.1.4.1.6626.6000.4.21.1.1.5ColumnspvComboDspCommercialDescriptionread-onlycurrentCombo DSP sale description
1.3.6.1.4.1.6626.6000.4.21.1.1.6ColumnspvComboDspVersionread-onlycurrentCombo DSP version
1.3.6.1.4.1.6626.6000.4.21.1.1.7ColumnspvComboDspSerialNumberread-onlycurrentCombo DSP Serial Number
1.3.6.1.4.1.6626.6000.4.21.1.1.8ColumnspvComboDspProductionDateread-onlycurrentCombo DSP production date
1.3.6.1.4.1.6626.6000.4.21.1.1.9ColumnspvComboDspCommissionDateread-writecurrentCombo DSP commissioning date
1.3.6.1.4.1.6626.6000.4.21.1.1.10ColumnspvComboDspTemperatureread-onlycurrentCombo DSP temperature in (C)
1.3.6.1.4.1.6626.6000.4.21.1.1.11ColumnspvComboDspPwrOutUlread-onlycurrentCombo DSP power out ul (dBm)
1.3.6.1.4.1.6626.6000.4.21.1.1.12ColumnspvComboDspPwrOutDlread-onlycurrentCombo DSP power out dl(dBm)
1.3.6.1.4.1.6626.6000.4.21.1.1.13ColumnspvComboDspPwrInUlread-onlycurrentCombo DSP power in ul(dBm)
1.3.6.1.4.1.6626.6000.4.21.1.1.14ColumnspvComboDspPwrInDlread-onlycurrentCombo DSP power in dl(dBm)
1.3.6.1.4.1.6626.6000.4.21.1.1.15ColumnspvComboDspTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.21.1.1.16ColumnspvComboDspMaxGainread-onlycurrentCombo DSP maximum gain
1.3.6.1.4.1.6626.6000.4.21.1.1.17ColumnspvComboDspPresetMenuread-writecurrentCombo DSP preset menu
1.3.6.1.4.1.6626.6000.4.21.1.1.18ColumnspvComboDspNameread-writecurrentCombo DSP name
1.3.6.1.4.1.6626.6000.4.21.1.1.19ColumnspvComboDspBandTyperead-writecurrentCombo DSP Band Type: narrow or wide.
1.3.6.1.4.1.6626.6000.4.21.1.1.20ColumnspvComboDspSelectivityread-writecurrentWide band limit.
1.3.6.1.4.1.6626.6000.4.21.1.1.21ColumnspvComboDspUserModuleAttDlread-writecurrentCombo DSP User Module Downlink Attenuation
1.3.6.1.4.1.6626.6000.4.21.1.1.22ColumnspvComboDspUserModuleAttUlread-writecurrentCombo DSP User Module Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.21.1.1.31ColumnspvComboDspSelfOscillatorStateread-onlycurrentself oscillator state: 0=Ok,1=Lowered Gain,2=RF Off,3=ALC On
1.3.6.1.4.1.6626.6000.4.21.1.1.32ColumnspvComboDspSelfOscillatorEnableread-writecurrentself oscillator enable
1.3.6.1.4.1.6626.6000.4.21.1.1.33ColumnspvComboDspSelfOscillatorClearread-writecurrentself oscillator clear command
1.3.6.1.4.1.6626.6000.4.21.1.1.34ColumnspvComboDspUserServiceAttDlread-onlycurrentCombo DSP User Module Downlink Attenuation
1.3.6.1.4.1.6626.6000.4.21.1.1.35ColumnspvComboDspUserServiceAttUlread-onlycurrentCombo DSP User Module Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.21.1.1.36ColumnspvComboDspVendorIdread-onlycurrentCombo DSP User Module Downlink Attenuation
1.3.6.1.4.1.6626.6000.4.21.1.1.37ColumnspvComboDspSelfOscillatorRestoreread-writecurrentself oscillator restore command
1.3.6.1.4.1.6626.6000.4.21.1.1.38ColumnspvComboDspUserModuleAttPrevDlread-onlycurrentDFE User Module Downlink Attenuation
1.3.6.1.4.1.6626.6000.4.21.1.1.39ColumnspvComboDspUserModuleAttPrevUlread-onlycurrentDFE User Module Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.21.1.1.40ColumnspvComboDspDataTimestampread-writecurrentCombo DSP last updated timestamp
1.3.6.1.4.1.6626.6000.4.21.1.1.41ColumnspvComboDspDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.21.1.1.42ColumnspvComboDspDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.21.1.1.43ColumnspvComboDspGainDlread-writecurrentCombo DSP User Module Downlink Attenuation
1.3.6.1.4.1.6626.6000.4.21.1.1.44ColumnspvComboDspGainUlread-writecurrentCombo DSP User Module Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.21.2TablespvComboDspChTablenot-accessiblecurrentCombo Dsp Receivers table
1.3.6.1.4.1.6626.6000.4.21.2.1RowspvComboDspChEntrynot-accessiblecurrentCombo Dsp receivers table entry
1.3.6.1.4.1.6626.6000.4.21.2.1.1ColumnspvComboDspChIndexnot-accessiblecurrentCombo Dsp receiver index
1.3.6.1.4.1.6626.6000.4.21.2.1.2ColumnspvComboDspEnableUlChread-writecurrentCombo Dsp UL enable
1.3.6.1.4.1.6626.6000.4.21.2.1.3ColumnspvComboDspEnableDlChread-writecurrentCombo Dsp DL enable
1.3.6.1.4.1.6626.6000.4.21.2.1.4ColumnspvComboDspPwrUlChread-onlycurrentCombo Dsp power (dBm)
1.3.6.1.4.1.6626.6000.4.21.2.1.5ColumnspvComboDspPwrDlChread-onlycurrentCombo Dsp power (dBm)
1.3.6.1.4.1.6626.6000.4.21.2.1.6ColumnspvComboDspAttUlChread-writecurrentCombo Dsp attenuation for UL.
1.3.6.1.4.1.6626.6000.4.21.2.1.7ColumnspvComboDspAttDlChread-writecurrentCombo Dsp attenuation for DL.
1.3.6.1.4.1.6626.6000.4.21.2.1.8ColumnspvComboDspFrqChread-writecurrentDescription.
1.3.6.1.4.1.6626.6000.4.21.2.1.9ColumnspvComboDspBwtChread-writecurrentDescription.
1.3.6.1.4.1.6626.6000.4.21.2.1.10ColumnspvComboDspFilterIdChread-onlycurrentFilter ID.
1.3.6.1.4.1.6626.6000.4.21.2.1.11ColumnspvComboDspThrPwrInDlMinChread-writecurrentDescription.
1.3.6.1.4.1.6626.6000.4.21.2.1.12ColumnspvComboDspThrPwrInDlMaxChread-writecurrentDescription.
1.3.6.1.4.1.6626.6000.4.21.2.1.13ColumnspvComboDspThrPwrOutUlMaxChread-writecurrentDescription.
1.3.6.1.4.1.6626.6000.4.21.3NodespvComboDspAlarm
1.3.6.1.4.1.6626.6000.4.21.3.1TablespvComboDspAlarmGlobalTablenot-accessiblecurrentDFE alarms global table
1.3.6.1.4.1.6626.6000.4.21.3.1.1RowspvComboDspAlarmGlobalEntrynot-accessiblecurrentDFE alarms global table entry
1.3.6.1.4.1.6626.6000.4.21.3.1.1.1ColumnspvComboDspAlarmGlobalCountread-onlycurrentDFE alarms global count
1.3.6.1.4.1.6626.6000.4.21.3.1.1.2ColumnspvComboDspAlarmMaxSeverityread-onlycurrentDFE alarms max severity
1.3.6.1.4.1.6626.6000.4.21.3.1.1.3ColumnspvComboDspReachableread-onlycurrentDFE reachable
1.3.6.1.4.1.6626.6000.4.21.3.2TablespvComboDspAlarmTablenot-accessiblecurrentDFE alarms table
1.3.6.1.4.1.6626.6000.4.21.3.2.1RowspvComboDspAlarmEntrynot-accessiblecurrentDFE alarms table entry
1.3.6.1.4.1.6626.6000.4.21.3.2.1.1ColumnspvComboDspAlarmTypenot-accessiblecurrentCombo DSP Alarm Type
1.3.6.1.4.1.6626.6000.4.21.3.2.1.2ColumnspvComboDspAlarmEnableread-writecurrentCombo DSP Alarm Enable
1.3.6.1.4.1.6626.6000.4.21.3.2.1.3ColumnspvComboDspAlarmStateread-onlycurrentCombo DSP Alarm State
1.3.6.1.4.1.6626.6000.4.21.3.2.1.4ColumnspvComboDspAlarmSeverityread-onlycurrentCombo DSP Alarm Severity
1.3.6.1.4.1.6626.6000.4.21.3.2.1.5ColumnspvComboDspAlarmPolarityread-onlycurrentCombo DSP Alarm Polarity
1.3.6.1.4.1.6626.6000.4.21.3.2.1.6ColumnspvComboDspAlarmNameread-onlycurrentCombo DSP Alarm Name
1.3.6.1.4.1.6626.6000.4.24NodespvPsuS
1.3.6.1.4.1.6626.6000.4.24.1TablespvPsuSTablenot-accessiblecurrentPSU table
1.3.6.1.4.1.6626.6000.4.24.1.1RowspvPsuSEntrynot-accessiblecurrentPSU table entry
1.3.6.1.4.1.6626.6000.4.24.1.1.1ColumnspvPsuSIndexnot-accessiblecurrentPSU table index
1.3.6.1.4.1.6626.6000.4.24.1.1.2ColumnspvPsuSTyperead-onlycurrentPSU type
1.3.6.1.4.1.6626.6000.4.24.1.1.3ColumnspvPsuSModelread-onlycurrentPSU model
1.3.6.1.4.1.6626.6000.4.24.1.1.4ColumnspvPsuSCommercialCoderead-onlycurrentPSU sale code
1.3.6.1.4.1.6626.6000.4.24.1.1.5ColumnspvPsuSCommercialDescriptionread-onlycurrentPSU sale description
1.3.6.1.4.1.6626.6000.4.24.1.1.6ColumnspvPsuSVersionread-onlycurrentPSU version
1.3.6.1.4.1.6626.6000.4.24.1.1.7ColumnspvPsuSSerialNumberread-onlycurrentPSU serial number
1.3.6.1.4.1.6626.6000.4.24.1.1.8ColumnspvPsuSProductionDateread-onlycurrentPSU production date
1.3.6.1.4.1.6626.6000.4.24.1.1.9ColumnspvPsuSCommissionDateread-writecurrentPSU commissioning date
1.3.6.1.4.1.6626.6000.4.24.1.1.10ColumnspvPsuSEnableread-onlycurrentPSU enable
1.3.6.1.4.1.6626.6000.4.24.1.1.11ColumnspvPsuSVoutread-onlycurrentPSU Vout in Volt
1.3.6.1.4.1.6626.6000.4.24.1.1.12ColumnspvPsuSTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.24.1.1.13ColumnspvPsuSVendorIdread-onlycurrentvendor id
1.3.6.1.4.1.6626.6000.4.24.1.1.14ColumnspvPsuSTemperature1read-onlycurrentPSU temperature in (C)
1.3.6.1.4.1.6626.6000.4.24.1.1.15ColumnspvPsuSTemperature2read-onlycurrentPSU temperature in (C)
1.3.6.1.4.1.6626.6000.4.24.1.1.16ColumnspvPsuSTemperature3read-onlycurrentPSU temperature in (C)
1.3.6.1.4.1.6626.6000.4.24.1.1.17ColumnspvPsuSCurrent1read-onlycurrentPSU current in mA
1.3.6.1.4.1.6626.6000.4.24.1.1.18ColumnspvPsuSCurrent2read-onlycurrentPSU current in mA
1.3.6.1.4.1.6626.6000.4.24.1.1.19ColumnspvPsuSCurrent3read-onlycurrentPSU current in mA
1.3.6.1.4.1.6626.6000.4.24.1.1.20ColumnspvPsuSDataTimestampread-onlycurrentPSU production date
1.3.6.1.4.1.6626.6000.4.24.1.1.21ColumnspvPsuSDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.24.1.1.22ColumnspvPsuSDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.24.2NodespvPsuSAlarm
1.3.6.1.4.1.6626.6000.4.24.2.1TablespvPsuSAlarmGlobalTablenot-accessiblecurrentPSU alarms global table
1.3.6.1.4.1.6626.6000.4.24.2.1.1RowspvPsuSAlarmGlobalEntrynot-accessiblecurrentPSU alarms global table entry
1.3.6.1.4.1.6626.6000.4.24.2.1.1.1ColumnspvPsuSAlarmGlobalCountread-onlycurrentPSU alarms global count
1.3.6.1.4.1.6626.6000.4.24.2.1.1.2ColumnspvPsuSAlarmMaxSeverityread-onlycurrentPSU alarms max severity
1.3.6.1.4.1.6626.6000.4.24.2.1.1.3ColumnspvPsuSReachableread-onlycurrentPSU reachable
1.3.6.1.4.1.6626.6000.4.24.2.2TablespvPsuSAlarmTablenot-accessiblecurrentPSU alarms table
1.3.6.1.4.1.6626.6000.4.24.2.2.1RowspvPsuSAlarmEntrynot-accessiblecurrentPSU alarms table entry
1.3.6.1.4.1.6626.6000.4.24.2.2.1.1ColumnspvPsuSAlarmTypenot-accessiblecurrentPSU alarm type
1.3.6.1.4.1.6626.6000.4.24.2.2.1.2ColumnspvPsuSAlarmEnableread-writecurrentPSU alarm enable
1.3.6.1.4.1.6626.6000.4.24.2.2.1.3ColumnspvPsuSAlarmStateread-onlycurrentPSU alarm state
1.3.6.1.4.1.6626.6000.4.24.2.2.1.4ColumnspvPsuSAlarmSeverityread-writecurrentPSU alarm severity
1.3.6.1.4.1.6626.6000.4.24.2.2.1.5ColumnspvPsuSAlarmPolarityread-writecurrentPSU alarm severity
1.3.6.1.4.1.6626.6000.4.24.2.2.1.6ColumnspvPsuSAlarmNameread-writecurrentPSU alarm name
1.3.6.1.4.1.6626.6000.4.25NodespvIntrainSpv
1.3.6.1.4.1.6626.6000.4.25.1TablespvIntrainSpvTablenot-accessiblecurrentTBD
1.3.6.1.4.1.6626.6000.4.25.1.1RowspvIntrainSpvEntrynot-accessiblecurrentTBD
1.3.6.1.4.1.6626.6000.4.25.1.1.1ColumnspvIntrainSpvIndexnot-accessiblecurrentIntrain Spv index in the system (1-16)
1.3.6.1.4.1.6626.6000.4.25.1.1.2ColumnspvIntrainSpvTyperead-onlycurrentIntrain Spv type
1.3.6.1.4.1.6626.6000.4.25.1.1.3ColumnspvIntrainSpvModelread-onlycurrentIntrain Spv model
1.3.6.1.4.1.6626.6000.4.25.1.1.4ColumnspvIntrainSpvCommercialCoderead-onlycurrentIntrain Spv sale code
1.3.6.1.4.1.6626.6000.4.25.1.1.5ColumnspvIntrainSpvCommercialDescriptionread-onlycurrentIntrain Spv sale description
1.3.6.1.4.1.6626.6000.4.25.1.1.6ColumnspvIntrainSpvVersionread-onlycurrentIntrain Spv version
1.3.6.1.4.1.6626.6000.4.25.1.1.7ColumnspvIntrainSpvNameread-writecurrentIntrain Spv name
1.3.6.1.4.1.6626.6000.4.25.1.1.8ColumnspvIntrainSpvDescriptionread-writecurrentIntrain Spv description
1.3.6.1.4.1.6626.6000.4.25.1.1.9ColumnspvIntrainSpvLocationLatituderead-writecurrentIntrain Spv latitude
1.3.6.1.4.1.6626.6000.4.25.1.1.10ColumnspvIntrainSpvLocationLongituderead-writecurrentIntrain Spv longitude
1.3.6.1.4.1.6626.6000.4.25.1.1.11ColumnspvIntrainSpvSerialNumberread-onlycurrentIntrain Spv serial number
1.3.6.1.4.1.6626.6000.4.25.1.1.12ColumnspvIntrainSpvProductionDateread-onlycurrentIntrain Spv production date
1.3.6.1.4.1.6626.6000.4.25.1.1.13ColumnspvIntrainSpvCommissionDateread-writecurrentIntrain Spv commissioning date
1.3.6.1.4.1.6626.6000.4.25.1.1.14ColumnspvIntrainSpvTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.25.1.1.15ColumnspvIntrainSpvVendorIdread-onlycurrentvendor id
1.3.6.1.4.1.6626.6000.4.25.1.1.16ColumnspvIntrainSpvDataTimestampread-onlycurrentIntrain Spv production date
1.3.6.1.4.1.6626.6000.4.25.1.1.17ColumnspvIntrainSpvDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.25.1.1.18ColumnspvIntrainSpvDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.25.2TablespvIntrainSpvRelayTablenot-accessiblecurrentIntrain Spv relays table
1.3.6.1.4.1.6626.6000.4.25.2.1RowspvIntrainSpvRelayEntrynot-accessiblecurrentIntrain Spv relay table entry
1.3.6.1.4.1.6626.6000.4.25.2.1.1ColumnspvIntrainSpvRelayIndexnot-accessiblecurrentIndex of a relay
1.3.6.1.4.1.6626.6000.4.25.2.1.2ColumnspvIntrainSpvRelayStateread-onlycurrentPhisical state of the relay.
1.3.6.1.4.1.6626.6000.4.25.2.1.3ColumnspvIntrainSpvRelayNameread-writecurrentA short description of the relay.
1.3.6.1.4.1.6626.6000.4.25.2.1.4ColumnspvIntrainSpvRelayPolicyread-writecurrentAuto relay policy based on alarm states.
1.3.6.1.4.1.6626.6000.4.25.2.1.5ColumnspvIntrainSpvRelayNcread-writecurrentNormal state of the relay.
1.3.6.1.4.1.6626.6000.4.25.3NodespvIntrainSpvAlarm
1.3.6.1.4.1.6626.6000.4.25.3.1TablespvIntrainSpvAlarmGlobalTablenot-accessiblecurrentIntrain Spv alarms global table
1.3.6.1.4.1.6626.6000.4.25.3.1.1RowspvIntrainSpvAlarmGlobalEntrynot-accessiblecurrentIntrain Spv alarms global table entry
1.3.6.1.4.1.6626.6000.4.25.3.1.1.1ColumnspvIntrainSpvAlarmGlobalCountread-onlycurrentIntrain Spv alarms global count
1.3.6.1.4.1.6626.6000.4.25.3.1.1.2ColumnspvIntrainSpvAlarmMaxSeverityread-onlycurrentIntrain Spv alarms max severity
1.3.6.1.4.1.6626.6000.4.25.3.1.1.3ColumnspvIntrainSpvAlarmGlobalCountAllread-onlycurrentIntrain Spv alarms global count all
1.3.6.1.4.1.6626.6000.4.25.3.1.1.4ColumnspvIntrainSpvAlarmMaxSeverityAllread-onlycurrentIntrain Spv alarms max severity all
1.3.6.1.4.1.6626.6000.4.25.3.1.1.5ColumnspvIntrainSpvReachableread-onlycurrentIntrain Spv reachable
1.3.6.1.4.1.6626.6000.4.25.3.2TablespvIntrainSpvAlarmTablenot-accessiblecurrentIntrain Spv alarm table
1.3.6.1.4.1.6626.6000.4.25.3.2.1RowspvIntrainSpvAlarmEntrynot-accessiblecurrentIntrain Spv alarm table entry
1.3.6.1.4.1.6626.6000.4.25.3.2.1.1ColumnspvIntrainSpvAlarmTypenot-accessiblecurrentIntrain Spv alarm type
1.3.6.1.4.1.6626.6000.4.25.3.2.1.2ColumnspvIntrainSpvAlarmEnableread-writecurrentIntrain Spv alarm enable
1.3.6.1.4.1.6626.6000.4.25.3.2.1.3ColumnspvIntrainSpvAlarmStateread-onlycurrentIntrain Spv alarm current state
1.3.6.1.4.1.6626.6000.4.25.3.2.1.4ColumnspvIntrainSpvAlarmSeverityread-onlycurrentIntrain Spv alarm severity
1.3.6.1.4.1.6626.6000.4.25.3.2.1.5ColumnspvIntrainSpvAlarmNameread-onlycurrentIntrain Spv alarm name
1.3.6.1.4.1.6626.6000.4.25.3.2.1.6ColumnspvIntrainSpvAlarmPolarityread-onlycurrentIntrain Spv alarm polarity
1.3.6.1.4.1.6626.6000.4.26NodespvIntrainBda
1.3.6.1.4.1.6626.6000.4.26.1TablespvIntrainBdaTablenot-accessiblecurrentIntrainBda table
1.3.6.1.4.1.6626.6000.4.26.1.1RowspvIntrainBdaEntrynot-accessiblecurrentIntrainBda table entry
1.3.6.1.4.1.6626.6000.4.26.1.1.1ColumnspvIntrainBdaIndexnot-accessiblecurrentIntrainBda index
1.3.6.1.4.1.6626.6000.4.26.1.1.2ColumnspvIntrainBdaTyperead-onlycurrentIntrainBda type
1.3.6.1.4.1.6626.6000.4.26.1.1.3ColumnspvIntrainBdaModelread-onlycurrentIntrainBda model
1.3.6.1.4.1.6626.6000.4.26.1.1.4ColumnspvIntrainBdaCommercialCoderead-onlycurrentIntrainBda sale code
1.3.6.1.4.1.6626.6000.4.26.1.1.5ColumnspvIntrainBdaCommercialDescriptionread-onlycurrentIntrainBda sale description
1.3.6.1.4.1.6626.6000.4.26.1.1.6ColumnspvIntrainBdaVersionread-onlycurrentIntrainBda version
1.3.6.1.4.1.6626.6000.4.26.1.1.7ColumnspvIntrainBdaSerialNumberread-onlycurrentIntrainBda serial number
1.3.6.1.4.1.6626.6000.4.26.1.1.8ColumnspvIntrainBdaProductionDateread-onlycurrentIntrainBda production date
1.3.6.1.4.1.6626.6000.4.26.1.1.9ColumnspvIntrainBdaCommissionDateread-writecurrentIntrainBda commissioning date
1.3.6.1.4.1.6626.6000.4.26.1.1.10ColumnspvIntrainBdaVendorIdread-onlycurrentvendor id
1.3.6.1.4.1.6626.6000.4.26.1.1.11ColumnspvIntrainBdaTemperatureread-onlycurrentIntrainBda temperature in (C)
1.3.6.1.4.1.6626.6000.4.26.1.1.12ColumnspvIntrainBdaPwrOutRmsUlread-onlycurrentIntrainBda power out ul (dBm)
1.3.6.1.4.1.6626.6000.4.26.1.1.13ColumnspvIntrainBdaPwrOutRmsDlread-onlycurrentIntrainBda power out dl(dBm)
1.3.6.1.4.1.6626.6000.4.26.1.1.14ColumnspvIntrainBdaPwrOutPeakUlread-onlycurrentIntrainBda power in ul(dBm)
1.3.6.1.4.1.6626.6000.4.26.1.1.15ColumnspvIntrainBdaPwrOutPeakDlread-onlycurrentIntrainBda power in dl(dBm)
1.3.6.1.4.1.6626.6000.4.26.1.1.16ColumnspvIntrainBdaTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.26.1.1.17ColumnspvIntrainBdaNameread-writecurrentIntrainBda name
1.3.6.1.4.1.6626.6000.4.26.1.1.18ColumnspvIntrainBdaUserModuleAttUlread-onlycurrentIntrainBda User Module Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.26.1.1.19ColumnspvIntrainBdaUserModuleAttDlread-onlycurrentIntrainBda User Module Downlink Attenuation
1.3.6.1.4.1.6626.6000.4.26.1.1.20ColumnspvIntrainBdaEnableUlread-writecurrentIntrainBda UL enable
1.3.6.1.4.1.6626.6000.4.26.1.1.21ColumnspvIntrainBdaEnableDlread-onlycurrentIntrainBda DL enable
1.3.6.1.4.1.6626.6000.4.26.1.1.22ColumnspvIntrainBdaDataTimestampread-onlycurrentIntrainBda production date
1.3.6.1.4.1.6626.6000.4.26.1.1.23ColumnspvIntrainBdaDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.26.1.1.24ColumnspvIntrainBdaDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.26.1.1.25ColumnspvIntrainBdaMaxGainread-onlycurrentIntrain Bda Maximum Gain
1.3.6.1.4.1.6626.6000.4.26.1.1.26ColumnspvIntrainBdaGainDlread-writecurrentIntrain Bda Downlink Attenuation
1.3.6.1.4.1.6626.6000.4.26.1.1.27ColumnspvIntrainBdaGainUlread-writecurrentIntrain Bda Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.26.2NodespvIntrainBdaAlarm
1.3.6.1.4.1.6626.6000.4.26.2.1TablespvIntrainBdaAlarmGlobalTablenot-accessiblecurrentIntrainBda alarms global table
1.3.6.1.4.1.6626.6000.4.26.2.1.1RowspvIntrainBdaAlarmGlobalEntrynot-accessiblecurrentIntrainBda alarms global table entry
1.3.6.1.4.1.6626.6000.4.26.2.1.1.1ColumnspvIntrainBdaAlarmGlobalCountread-onlycurrentIntrainBda alarms global count
1.3.6.1.4.1.6626.6000.4.26.2.1.1.2ColumnspvIntrainBdaAlarmMaxSeverityread-onlycurrentIntrainBda alarms max severity
1.3.6.1.4.1.6626.6000.4.26.2.1.1.3ColumnspvIntrainBdaReachableread-onlycurrentIntrainBda reachable
1.3.6.1.4.1.6626.6000.4.26.2.2TablespvIntrainBdaAlarmTablenot-accessiblecurrentIntrainBda alarms table
1.3.6.1.4.1.6626.6000.4.26.2.2.1RowspvIntrainBdaAlarmEntrynot-accessiblecurrentIntrainBda alarms table entry
1.3.6.1.4.1.6626.6000.4.26.2.2.1.1ColumnspvIntrainBdaAlarmTypenot-accessiblecurrentIntrainBda alarm type
1.3.6.1.4.1.6626.6000.4.26.2.2.1.2ColumnspvIntrainBdaAlarmEnableread-writecurrentIntrainBda alarm enable
1.3.6.1.4.1.6626.6000.4.26.2.2.1.3ColumnspvIntrainBdaAlarmStateread-onlycurrentIntrainBda alarm state
1.3.6.1.4.1.6626.6000.4.26.2.2.1.4ColumnspvIntrainBdaAlarmSeverityread-onlycurrentIntrainBda alarm severity
1.3.6.1.4.1.6626.6000.4.26.2.2.1.5ColumnspvIntrainBdaAlarmPolarityread-onlycurrentIntrainBda alarm polarity
1.3.6.1.4.1.6626.6000.4.26.2.2.1.6ColumnspvIntrainBdaAlarmNameread-onlycurrentIntrainBda alarm name
1.3.6.1.4.1.6626.6000.4.27NodespvPwrDistributor
1.3.6.1.4.1.6626.6000.4.27.1TablespvPwrDistributorTablenot-accessiblecurrentPSU table
1.3.6.1.4.1.6626.6000.4.27.1.1RowspvPwrDistributorEntrynot-accessiblecurrentPSU table entry
1.3.6.1.4.1.6626.6000.4.27.1.1.1ColumnspvPwrDistributorIndexnot-accessiblecurrentPSU table index
1.3.6.1.4.1.6626.6000.4.27.1.1.2ColumnspvPwrDistributorTyperead-onlycurrentPSU type
1.3.6.1.4.1.6626.6000.4.27.1.1.3ColumnspvPwrDistributorModelread-onlycurrentPSU model
1.3.6.1.4.1.6626.6000.4.27.1.1.4ColumnspvPwrDistributorCommercialCoderead-onlycurrentPSU sale code
1.3.6.1.4.1.6626.6000.4.27.1.1.5ColumnspvPwrDistributorCommercialDescriptionread-onlycurrentPSU sale description
1.3.6.1.4.1.6626.6000.4.27.1.1.6ColumnspvPwrDistributorVersionread-onlycurrentPSU version
1.3.6.1.4.1.6626.6000.4.27.1.1.7ColumnspvPwrDistributorSerialNumberread-onlycurrentPSU serial number
1.3.6.1.4.1.6626.6000.4.27.1.1.8ColumnspvPwrDistributorProductionDateread-onlycurrentPSU production date
1.3.6.1.4.1.6626.6000.4.27.1.1.9ColumnspvPwrDistributorCommissionDateread-writecurrentPSU commissioning date
1.3.6.1.4.1.6626.6000.4.27.1.1.10ColumnspvPwrDistributorTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.27.1.1.11ColumnspvPwrDistributorVendorIdread-onlycurrentvendor id
1.3.6.1.4.1.6626.6000.4.27.1.1.12ColumnspvPwrDistributorDataTimestampread-onlycurrentPSU production date
1.3.6.1.4.1.6626.6000.4.27.1.1.13ColumnspvPwrDistributorDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.27.1.1.14ColumnspvPwrDistributorDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.27.1.1.15ColumnspvPwrDistributorVoutread-onlycurrentPSU Vout in Volt
1.3.6.1.4.1.6626.6000.4.27.1.1.16ColumnspvPwrDistributorTemperatureread-onlycurrentPSU temperature in (C)
1.3.6.1.4.1.6626.6000.4.27.1.1.17ColumnspvPwrDistributorEnableSubread-writecurrentPSU enable
1.3.6.1.4.1.6626.6000.4.27.1.1.18ColumnspvPwrDistributorEnableBlockread-writecurrentPSU enable block
1.3.6.1.4.1.6626.6000.4.27.2TablespvPwrDistributorChTablenot-accessiblecurrentPsu receivers table
1.3.6.1.4.1.6626.6000.4.27.2.1RowspvPwrDistributorChEntrynot-accessiblecurrentPwrDistributor receivers table entry
1.3.6.1.4.1.6626.6000.4.27.2.1.1ColumnspvPwrDistributorIndexChnot-accessiblecurrentPwrDistributor receiver index
1.3.6.1.4.1.6626.6000.4.27.2.1.2ColumnspvPwrDistributorEnableChread-onlycurrentPSU enable
1.3.6.1.4.1.6626.6000.4.27.2.1.3ColumnspvPwrDistributorCurrentChread-onlycurrentPSU current in mA
1.3.6.1.4.1.6626.6000.4.27.2.1.4ColumnspvPwrDistributorThrCurMaxChread-writecurrentPSU threshold cur in A
1.3.6.1.4.1.6626.6000.4.27.2.1.5ColumnspvPwrDistributorRuAddressChread-writecurrentR U address connected to enable ch
1.3.6.1.4.1.6626.6000.4.27.3NodespvPwrDistributorAlarm
1.3.6.1.4.1.6626.6000.4.27.3.1TablespvPwrDistributorAlarmGlobalTablenot-accessiblecurrentPSU alarms global table
1.3.6.1.4.1.6626.6000.4.27.3.1.1RowspvPwrDistributorAlarmGlobalEntrynot-accessiblecurrentPSU alarms global table entry
1.3.6.1.4.1.6626.6000.4.27.3.1.1.1ColumnspvPwrDistributorAlarmGlobalCountread-onlycurrentPSU alarms global count
1.3.6.1.4.1.6626.6000.4.27.3.1.1.2ColumnspvPwrDistributorAlarmMaxSeverityread-onlycurrentPSU alarms max severity
1.3.6.1.4.1.6626.6000.4.27.3.1.1.3ColumnspvPwrDistributorReachableread-onlycurrentPSU reachable
1.3.6.1.4.1.6626.6000.4.27.3.2TablespvPwrDistributorAlarmTablenot-accessiblecurrentPSU alarms table
1.3.6.1.4.1.6626.6000.4.27.3.2.1RowspvPwrDistributorAlarmEntrynot-accessiblecurrentPSU alarms table entry
1.3.6.1.4.1.6626.6000.4.27.3.2.1.1ColumnspvPwrDistributorAlarmTypenot-accessiblecurrentPSU alarm type
1.3.6.1.4.1.6626.6000.4.27.3.2.1.2ColumnspvPwrDistributorAlarmEnableread-writecurrentPSU alarm enable
1.3.6.1.4.1.6626.6000.4.27.3.2.1.3ColumnspvPwrDistributorAlarmStateread-onlycurrentPSU alarm state
1.3.6.1.4.1.6626.6000.4.27.3.2.1.4ColumnspvPwrDistributorAlarmSeverityread-writecurrentPSU alarm severity
1.3.6.1.4.1.6626.6000.4.27.3.2.1.5ColumnspvPwrDistributorAlarmPolarityread-writecurrentPSU alarm severity
1.3.6.1.4.1.6626.6000.4.27.3.2.1.6ColumnspvPwrDistributorAlarmNameread-writecurrentPSU alarm name
1.3.6.1.4.1.6626.6000.4.28NodespvDasTray
1.3.6.1.4.1.6626.6000.4.28.1TablespvDasTrayTablenot-accessiblecurrentDasTray table
1.3.6.1.4.1.6626.6000.4.28.1.1RowspvDasTrayEntrynot-accessiblecurrentDasTray table entry
1.3.6.1.4.1.6626.6000.4.28.1.1.1ColumnspvDasTrayIndexnot-accessiblecurrentDasTray index
1.3.6.1.4.1.6626.6000.4.28.1.1.2ColumnspvDasTrayTyperead-onlycurrentDasTray type
1.3.6.1.4.1.6626.6000.4.28.1.1.3ColumnspvDasTrayModelread-onlycurrentDasTray model
1.3.6.1.4.1.6626.6000.4.28.1.1.4ColumnspvDasTrayCommercialCoderead-onlycurrentDasTray sale code
1.3.6.1.4.1.6626.6000.4.28.1.1.5ColumnspvDasTrayCommercialDescriptionread-onlycurrentDasTray sale description
1.3.6.1.4.1.6626.6000.4.28.1.1.6ColumnspvDasTrayVersionread-onlycurrentDasTray version
1.3.6.1.4.1.6626.6000.4.28.1.1.7ColumnspvDasTraySerialNumberread-onlycurrentDasTray serial number
1.3.6.1.4.1.6626.6000.4.28.1.1.8ColumnspvDasTrayProductionDateread-onlycurrentDasTray production date
1.3.6.1.4.1.6626.6000.4.28.1.1.9ColumnspvDasTrayCommissionDateread-writecurrentDasTray commissioning date
1.3.6.1.4.1.6626.6000.4.28.1.1.10ColumnspvDasTrayVendorIdread-writecurrentDasTray Name, max 30 char
1.3.6.1.4.1.6626.6000.4.28.1.1.11ColumnspvDasTrayTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.28.1.1.12ColumnspvDasTrayDataTimestampread-onlycurrentDasTray production date
1.3.6.1.4.1.6626.6000.4.28.1.1.13ColumnspvDasTrayDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.28.1.1.14ColumnspvDasTrayDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.28.1.1.15ColumnspvDasTrayNameread-writecurrentDasTray Name, max 30 char
1.3.6.1.4.1.6626.6000.4.28.1.1.16ColumnspvDasTrayTemperatureread-onlycurrentDasTray temperature in (C)
1.3.6.1.4.1.6626.6000.4.28.1.1.17ColumnspvDasTrayPwrAlarmHysteresisread-writecurrentDasTray power hysteresis
1.3.6.1.4.1.6626.6000.4.28.1.1.18ColumnspvDasTrayPwrLimiterread-writecurrentDasTray power limiter menu
1.3.6.1.4.1.6626.6000.4.28.1.1.19ColumnspvDasTrayPwrLimiterModeread-writecurrentDasTray power limiter mode menu
1.3.6.1.4.1.6626.6000.4.28.1.1.20ColumnspvDasTrayPresetMenuread-writecurrentDasTray preset menu
1.3.6.1.4.1.6626.6000.4.28.2TablespvDasTrayChTablenot-accessiblecurrentDasTray alarms table
1.3.6.1.4.1.6626.6000.4.28.2.1RowspvDasTrayChEntrynot-accessiblecurrentDasTray alarms table entry
1.3.6.1.4.1.6626.6000.4.28.2.1.1ColumnspvDasTrayChIndexnot-accessiblecurrentDasTray attenuation (dB)
1.3.6.1.4.1.6626.6000.4.28.2.1.2ColumnspvDasTrayAttMecBtsDlread-writecurrentDasTray attenuation (dB)
1.3.6.1.4.1.6626.6000.4.28.2.1.3ColumnspvDasTrayAttDigBtsInDlread-writecurrentDasTray attenuation (dB)
1.3.6.1.4.1.6626.6000.4.28.2.1.4ColumnspvDasTrayAttDigDasOutDlread-writecurrentDasTray attenuation (dB)
1.3.6.1.4.1.6626.6000.4.28.2.1.5ColumnspvDasTrayRmsPwrDlread-onlycurrentDasTray RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.28.2.1.6ColumnspvDasTrayPeakPwrDlread-onlycurrentDasTray peak power (dBm)
1.3.6.1.4.1.6626.6000.4.28.2.1.7ColumnspvDasTrayThrMinRmsPwrDlread-writecurrentDasTray RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.28.2.1.8ColumnspvDasTrayThrMaxRmsPwrDlread-writecurrentDasTray RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.28.2.1.9ColumnspvDasTrayThrMaxPeakPwrDlread-writecurrentDasTray peak power (dBm)
1.3.6.1.4.1.6626.6000.4.28.2.1.10ColumnspvDasTrayAttDigDasInUlread-writecurrentDasTray attenuation (dB)
1.3.6.1.4.1.6626.6000.4.28.2.1.11ColumnspvDasTrayAttDigBtsMainUlread-writecurrentDasTray attenuation (dB)
1.3.6.1.4.1.6626.6000.4.28.2.1.12ColumnspvDasTrayAttDigBtsDivUlread-writecurrentDasTray attenuation (dB)
1.3.6.1.4.1.6626.6000.4.28.2.1.13ColumnspvDasTraySelectorUlread-writecurrentswitch LNA enable
1.3.6.1.4.1.6626.6000.4.28.2.1.14ColumnspvDasTrayRmsPwrUlread-onlycurrentDasTray RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.28.2.1.15ColumnspvDasTrayPeakPwrUlread-onlycurrentDasTray peak power (dBm)
1.3.6.1.4.1.6626.6000.4.28.2.1.16ColumnspvDasTrayRmsPwrDivUlread-onlycurrentDasTray RMS Power div (dBm)
1.3.6.1.4.1.6626.6000.4.28.2.1.17ColumnspvDasTrayPeakPwrDivUlread-onlycurrentDasTray peak power div (dBm)
1.3.6.1.4.1.6626.6000.4.28.2.1.18ColumnspvDasTraySwitchLnaread-writecurrentswitch LNA enable
1.3.6.1.4.1.6626.6000.4.28.2.1.19ColumnspvDasTrayClearOverdriveread-writecurrentClear Overdrive on the specified channel
1.3.6.1.4.1.6626.6000.4.28.2.1.20ColumnspvDasTrayRfOffread-writecurrentClear Overdrive on the specified channel
1.3.6.1.4.1.6626.6000.4.28.3TablespvDasTrayFanTablenot-accessiblecurrentDasTray alarms table
1.3.6.1.4.1.6626.6000.4.28.3.1RowspvDasTrayFanEntrynot-accessiblecurrentDasTray alarms table entry
1.3.6.1.4.1.6626.6000.4.28.3.1.1ColumnspvDasTrayFanIndexnot-accessiblecurrentDasTray fan enabled
1.3.6.1.4.1.6626.6000.4.28.3.1.2ColumnspvDasTrayFanEnableread-onlycurrentDasTray fan enabled
1.3.6.1.4.1.6626.6000.4.28.3.1.3ColumnspvDasTrayFanReadread-onlycurrentDasTray fan speed (rpm)
1.3.6.1.4.1.6626.6000.4.28.3.1.4ColumnspvDasTrayFanSetread-onlycurrentDasTray fan speed set (%)
1.3.6.1.4.1.6626.6000.4.28.4NodespvDasTrayAlarm
1.3.6.1.4.1.6626.6000.4.28.4.1TablespvDasTrayAlarmGlobalTablenot-accessiblecurrentDasTray alarms global table
1.3.6.1.4.1.6626.6000.4.28.4.1.1RowspvDasTrayAlarmGlobalEntrynot-accessiblecurrentDasTray alarms global table entry
1.3.6.1.4.1.6626.6000.4.28.4.1.1.1ColumnspvDasTrayAlarmGlobalCountread-onlycurrentDasTray alarms global count
1.3.6.1.4.1.6626.6000.4.28.4.1.1.2ColumnspvDasTrayAlarmMaxSeverityread-onlycurrentDasTray alarms max severity
1.3.6.1.4.1.6626.6000.4.28.4.1.1.3ColumnspvDasTrayReachableread-onlycurrentDasTray reachable
1.3.6.1.4.1.6626.6000.4.28.4.2TablespvDasTrayAlarmTablenot-accessiblecurrentDasTray alarms table
1.3.6.1.4.1.6626.6000.4.28.4.2.1RowspvDasTrayAlarmEntrynot-accessiblecurrentDasTray alarms table entry
1.3.6.1.4.1.6626.6000.4.28.4.2.1.1ColumnspvDasTrayAlarmTypenot-accessiblecurrentDasTray alarm type
1.3.6.1.4.1.6626.6000.4.28.4.2.1.2ColumnspvDasTrayAlarmEnableread-writecurrentDasTray alarm enable
1.3.6.1.4.1.6626.6000.4.28.4.2.1.3ColumnspvDasTrayAlarmStateread-onlycurrentDasTray alarm state
1.3.6.1.4.1.6626.6000.4.28.4.2.1.4ColumnspvDasTrayAlarmSeverityread-onlycurrentDasTray alarm severity
1.3.6.1.4.1.6626.6000.4.28.4.2.1.5ColumnspvDasTrayAlarmPolarityread-onlycurrentDasTray alarm polarity
1.3.6.1.4.1.6626.6000.4.28.4.2.1.6ColumnspvDasTrayAlarmNameread-onlycurrentDasTray alarm name
1.3.6.1.4.1.6626.6000.4.29NodespvRfSwitch
1.3.6.1.4.1.6626.6000.4.29.1TablespvRfSwitchTablenot-accessiblecurrentRF_SWITCH table
1.3.6.1.4.1.6626.6000.4.29.1.1RowspvRfSwitchEntrynot-accessiblecurrentRF_SWITCH table entry
1.3.6.1.4.1.6626.6000.4.29.1.1.1ColumnspvRfSwitchIndexnot-accessiblecurrentRF_SWITCH table index
1.3.6.1.4.1.6626.6000.4.29.1.1.2ColumnspvRfSwitchTyperead-onlycurrentRF_SWITCH type
1.3.6.1.4.1.6626.6000.4.29.1.1.3ColumnspvRfSwitchModelread-onlycurrentRF_SWITCH model
1.3.6.1.4.1.6626.6000.4.29.1.1.4ColumnspvRfSwitchCommercialCoderead-onlycurrentRF_SWITCH sale code
1.3.6.1.4.1.6626.6000.4.29.1.1.5ColumnspvRfSwitchCommercialDescriptionread-onlycurrentRF_SWITCH sale description
1.3.6.1.4.1.6626.6000.4.29.1.1.6ColumnspvRfSwitchVersionread-onlycurrentRF_SWITCH version
1.3.6.1.4.1.6626.6000.4.29.1.1.7ColumnspvRfSwitchSerialNumberread-onlycurrentRF_SWITCH serial number
1.3.6.1.4.1.6626.6000.4.29.1.1.8ColumnspvRfSwitchProductionDateread-onlycurrentRF_SWITCH production date
1.3.6.1.4.1.6626.6000.4.29.1.1.9ColumnspvRfSwitchCommissionDateread-writecurrentRF_SWITCH commissioning date
1.3.6.1.4.1.6626.6000.4.29.1.1.10ColumnspvRfSwitchTemperatureread-onlycurrentRF_SWITCH temperature in (C)
1.3.6.1.4.1.6626.6000.4.29.1.1.11ColumnspvRfSwitchCurrentread-onlycurrentRF_SWITCH current in mA
1.3.6.1.4.1.6626.6000.4.29.1.1.12ColumnspvRfSwitchModeread-writecurrentRF_SWITCH mode
1.3.6.1.4.1.6626.6000.4.29.1.1.13ColumnspvRfSwitchTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.29.1.1.14ColumnspvRfSwitchVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.29.1.1.15ColumnspvRfSwitchDataTimestampread-onlycurrentRF_SWITCH production date
1.3.6.1.4.1.6626.6000.4.29.1.1.16ColumnspvRfSwitchDataSourceread-writecurrentRF_SWITCH table index
1.3.6.1.4.1.6626.6000.4.29.1.1.17ColumnspvRfSwitchDataRestoreread-writecurrentRF_SWITCH table index
1.3.6.1.4.1.6626.6000.4.29.2TablespvRfSwitchDescrTablenot-accessiblecurrentwitch descr channel table
1.3.6.1.4.1.6626.6000.4.29.2.1RowspvRfSwitchDescrEntrynot-accessiblecurrentMotrx receivers table entry
1.3.6.1.4.1.6626.6000.4.29.2.1.1ColumnspvRfSwitchChIndexnot-accessiblecurrentRF Switch description index
1.3.6.1.4.1.6626.6000.4.29.2.1.2ColumnspvRfSwitchChDescriptionread-writecurrentRF Switch Description ch
1.3.6.1.4.1.6626.6000.4.29.3NodespvRfSwitchAlarm
1.3.6.1.4.1.6626.6000.4.29.3.1TablespvRfSwitchAlarmGlobalTablenot-accessiblecurrentRF_SWITCH alarms global table
1.3.6.1.4.1.6626.6000.4.29.3.1.1RowspvRfSwitchAlarmGlobalEntrynot-accessiblecurrentRF_SWITCH alarms global table entry
1.3.6.1.4.1.6626.6000.4.29.3.1.1.1ColumnspvRfSwitchAlarmGlobalCountread-onlycurrentRF_SWITCH alarms global count
1.3.6.1.4.1.6626.6000.4.29.3.1.1.2ColumnspvRfSwitchAlarmMaxSeverityread-onlycurrentRF_SWITCH alarms max severity
1.3.6.1.4.1.6626.6000.4.29.3.1.1.3ColumnspvRfSwitchReachableread-onlycurrentRF_SWITCH reachable
1.3.6.1.4.1.6626.6000.4.29.3.2TablespvRfSwitchAlarmTablenot-accessiblecurrentRF_SWITCH alarms table
1.3.6.1.4.1.6626.6000.4.29.3.2.1RowspvRfSwitchAlarmEntrynot-accessiblecurrentRF_SWITCH alarms table entry
1.3.6.1.4.1.6626.6000.4.29.3.2.1.1ColumnspvRfSwitchAlarmTypenot-accessiblecurrentRF_SWITCH alarm type
1.3.6.1.4.1.6626.6000.4.29.3.2.1.2ColumnspvRfSwitchAlarmEnableread-writecurrentRF_SWITCH alarm enable
1.3.6.1.4.1.6626.6000.4.29.3.2.1.3ColumnspvRfSwitchAlarmStateread-onlycurrentRF_SWITCH alarm state
1.3.6.1.4.1.6626.6000.4.29.3.2.1.4ColumnspvRfSwitchAlarmSeverityread-writecurrentRF_SWITCH alarm severity
1.3.6.1.4.1.6626.6000.4.29.3.2.1.5ColumnspvRfSwitchAlarmPolarityread-writecurrentRF_SWITCH alarm polarity
1.3.6.1.4.1.6626.6000.4.29.3.2.1.6ColumnspvRfSwitchAlarmNameread-writecurrentRF_SWITCH alarm name
1.3.6.1.4.1.6626.6000.4.30NodespvDfeF32Ch
1.3.6.1.4.1.6626.6000.4.30.1TablespvDfeF32ChTablenot-accessiblecurrentDFE-F32CH table
1.3.6.1.4.1.6626.6000.4.30.1.1RowspvDfeF32ChEntrynot-accessiblecurrentDFE-F32CH table entry
1.3.6.1.4.1.6626.6000.4.30.1.1.1ColumnspvDfeF32ChIndexnot-accessiblecurrentDFE-F32CH index
1.3.6.1.4.1.6626.6000.4.30.1.1.2ColumnspvDfeF32ChTyperead-onlycurrentDFE-F32CH type
1.3.6.1.4.1.6626.6000.4.30.1.1.3ColumnspvDfeF32ChModelread-onlycurrentDFE-F32CH model
1.3.6.1.4.1.6626.6000.4.30.1.1.4ColumnspvDfeF32ChCommercialCoderead-onlycurrentDFE-F32CH sale code
1.3.6.1.4.1.6626.6000.4.30.1.1.5ColumnspvDfeF32ChCommercialDescriptionread-onlycurrentDFE-F32CH sale description
1.3.6.1.4.1.6626.6000.4.30.1.1.6ColumnspvDfeF32ChVersionread-onlycurrentDFE-F32CH version
1.3.6.1.4.1.6626.6000.4.30.1.1.7ColumnspvDfeF32ChSerialNumberread-onlycurrentDFE-F32CH serial number
1.3.6.1.4.1.6626.6000.4.30.1.1.8ColumnspvDfeF32ChProductionDateread-onlycurrentDFE-F32CH production date
1.3.6.1.4.1.6626.6000.4.30.1.1.9ColumnspvDfeF32ChCommissionDateread-writecurrentDFE-F32CH commissioning date
1.3.6.1.4.1.6626.6000.4.30.1.1.10ColumnspvDfeF32ChVendorIdread-onlycurrentself oscillator clear command
1.3.6.1.4.1.6626.6000.4.30.1.1.11ColumnspvDfeF32ChTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.30.1.1.12ColumnspvDfeF32ChTemperatureread-onlycurrentDFE-F32CH temperature in (C)
1.3.6.1.4.1.6626.6000.4.30.1.1.13ColumnspvDfeF32ChPwrOutread-onlycurrentDFE-F32CH power out (dBm)
1.3.6.1.4.1.6626.6000.4.30.1.1.14ColumnspvDfeF32ChPwrInread-onlycurrentDFE-F32CH power in (dBm)
1.3.6.1.4.1.6626.6000.4.30.1.1.15ColumnspvDfeF32ChPresetMenuread-writecurrentDFE-F32CH preset menu
1.3.6.1.4.1.6626.6000.4.30.1.1.16ColumnspvDfeF32ChNameread-writecurrentDFE-F32CH name
1.3.6.1.4.1.6626.6000.4.30.1.1.17ColumnspvDfeF32ChUserModuleAttread-onlycurrentDFE-F32CH User Module Uplink Attenuation
1.3.6.1.4.1.6626.6000.4.30.1.1.18ColumnspvDfeF32ChUserModuleAttPrevread-onlycurrentDFE-F32CH User Module Uplink Attenuation previous
1.3.6.1.4.1.6626.6000.4.30.1.1.27ColumnspvDfeF32ChSelfOscillatorStateread-onlycurrentself oscillator state: 0=Ok,1=Lowered Gain,2=RF Off,3=ALC On
1.3.6.1.4.1.6626.6000.4.30.1.1.28ColumnspvDfeF32ChSelfOscillatorEnableread-writecurrentself oscillator enable
1.3.6.1.4.1.6626.6000.4.30.1.1.29ColumnspvDfeF32ChSelfOscillatorClearread-writecurrentself oscillator clear command
1.3.6.1.4.1.6626.6000.4.30.1.1.30ColumnspvDfeF32ChSelfOscillatorRestoreread-writecurrentself oscillator restore command
1.3.6.1.4.1.6626.6000.4.30.1.1.31ColumnspvDfeF32ChChannelConfigread-onlycurrentChannel configuration
1.3.6.1.4.1.6626.6000.4.30.1.1.32ColumnspvDfeF32ChDataTimestampread-onlycurrentDFE-F32CH production date
1.3.6.1.4.1.6626.6000.4.30.1.1.33ColumnspvDfeF32ChDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.30.1.1.34ColumnspvDfeF32ChDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.30.2TablespvDfeF32ChChTablenot-accessiblecurrentDFE-F32CH receivers table
1.3.6.1.4.1.6626.6000.4.30.2.1RowspvDfeF32ChChEntrynot-accessiblecurrentDFE-F32CH receivers table entry
1.3.6.1.4.1.6626.6000.4.30.2.1.1ColumnspvDfeF32ChChIndexnot-accessiblecurrentDFE-F32CH receiver index
1.3.6.1.4.1.6626.6000.4.30.2.1.2ColumnspvDfeF32ChEnableChread-writecurrentDFE-F32CH Ul enable
1.3.6.1.4.1.6626.6000.4.30.2.1.3ColumnspvDfeF32ChPwrChread-onlycurrentDFE-F32CH power (dBm)
1.3.6.1.4.1.6626.6000.4.30.2.1.4ColumnspvDfeF32ChAttChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.30.2.1.5ColumnspvDfeF32ChFrqChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.30.2.1.6ColumnspvDfeF32ChBwtChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.30.2.1.7ColumnspvDfeF32ChThrPwrMinChread-writecurrentThreshold Pwr Min (dBm).
1.3.6.1.4.1.6626.6000.4.30.2.1.8ColumnspvDfeF32ChThrAlcChread-writecurrentThreshold ALC (dBm).
1.3.6.1.4.1.6626.6000.4.30.2.1.9ColumnspvDfeF32ChPwrSwitchChread-writecurrentDFE-F32CH peak - rms
1.3.6.1.4.1.6626.6000.4.30.3NodespvDfeF32ChAlarm
1.3.6.1.4.1.6626.6000.4.30.3.1TablespvDfeF32ChAlarmGlobalTablenot-accessiblecurrentDFE-F32CH alarms global table
1.3.6.1.4.1.6626.6000.4.30.3.1.1RowspvDfeF32ChAlarmGlobalEntrynot-accessiblecurrentDFE-F32CH alarms global table entry
1.3.6.1.4.1.6626.6000.4.30.3.1.1.1ColumnspvDfeF32ChAlarmGlobalCountread-onlycurrentDFE-F32CH alarms global count
1.3.6.1.4.1.6626.6000.4.30.3.1.1.2ColumnspvDfeF32ChAlarmMaxSeverityread-onlycurrentDFE-F32CH alarms max severity
1.3.6.1.4.1.6626.6000.4.30.3.1.1.3ColumnspvDfeF32ChReachableread-onlycurrentDFE-F32CH reachable
1.3.6.1.4.1.6626.6000.4.30.3.2TablespvDfeF32ChAlarmTablenot-accessiblecurrentDFE-F32CH alarms table
1.3.6.1.4.1.6626.6000.4.30.3.2.1RowspvDfeF32ChAlarmEntrynot-accessiblecurrentDFE-F32CH alarms table entry
1.3.6.1.4.1.6626.6000.4.30.3.2.1.1ColumnspvDfeF32ChAlarmTypenot-accessiblecurrentDFE-F32CH alarm type
1.3.6.1.4.1.6626.6000.4.30.3.2.1.2ColumnspvDfeF32ChAlarmEnableread-writecurrentDFE-F32CH alarm enable
1.3.6.1.4.1.6626.6000.4.30.3.2.1.3ColumnspvDfeF32ChAlarmStateread-onlycurrentDFE-F32CH alarm state
1.3.6.1.4.1.6626.6000.4.30.3.2.1.4ColumnspvDfeF32ChAlarmSeverityread-onlycurrentDFE-F32CH alarm severity
1.3.6.1.4.1.6626.6000.4.30.3.2.1.5ColumnspvDfeF32ChAlarmPolarityread-onlycurrentDFE-F32CH alarm Polarity
1.3.6.1.4.1.6626.6000.4.30.3.2.1.6ColumnspvDfeF32ChAlarmNameread-onlycurrentDFE-F32CH alarm name
1.3.6.1.4.1.6626.6000.4.31NodespvTddS
1.3.6.1.4.1.6626.6000.4.31.1TablespvTddSTablenot-accessiblecurrentTDDS table
1.3.6.1.4.1.6626.6000.4.31.1.1RowspvTddSEntrynot-accessiblecurrentTDDS table entry
1.3.6.1.4.1.6626.6000.4.31.1.1.1ColumnspvTddSIndexnot-accessiblecurrentTDDS index
1.3.6.1.4.1.6626.6000.4.31.1.1.2ColumnspvTddSTyperead-onlycurrentTDDS type
1.3.6.1.4.1.6626.6000.4.31.1.1.3ColumnspvTddSModelread-onlycurrentTDDS model
1.3.6.1.4.1.6626.6000.4.31.1.1.4ColumnspvTddSCommercialCoderead-onlycurrentTDDS sale code
1.3.6.1.4.1.6626.6000.4.31.1.1.5ColumnspvTddSCommercialDescriptionread-onlycurrentTDDS sale description
1.3.6.1.4.1.6626.6000.4.31.1.1.6ColumnspvTddSVersionread-onlycurrentTDDS version
1.3.6.1.4.1.6626.6000.4.31.1.1.7ColumnspvTddSSerialNumberread-onlycurrentTDDS serial number
1.3.6.1.4.1.6626.6000.4.31.1.1.8ColumnspvTddSProductionDateread-onlycurrentTDDS production date
1.3.6.1.4.1.6626.6000.4.31.1.1.9ColumnspvTddSCommissionDateread-writecurrentTDDS commissioning date
1.3.6.1.4.1.6626.6000.4.31.1.1.10ColumnspvTddSTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.31.1.1.11ColumnspvTddSVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.31.1.1.12ColumnspvTddSDataSourceread-writecurrentTDDS index
1.3.6.1.4.1.6626.6000.4.31.1.1.13ColumnspvTddSDataRestoreread-writecurrentTDDS index
1.3.6.1.4.1.6626.6000.4.31.1.1.14ColumnspvTddSDataTimestampread-onlycurrentTDDS production date
1.3.6.1.4.1.6626.6000.4.31.1.1.15ColumnspvTddSTemperatureread-onlycurrentTDDS temperature in (C)
1.3.6.1.4.1.6626.6000.4.31.1.1.16ColumnspvTddSVControlread-onlycurrentTDDS Tx power (dBm)
1.3.6.1.4.1.6626.6000.4.31.1.1.17ColumnspvTddSCur28vread-onlycurrentTDDS Tx cur 28v
1.3.6.1.4.1.6626.6000.4.31.1.1.18ColumnspvTddSPwrEnableread-writecurrentTDDS power on enable
1.3.6.1.4.1.6626.6000.4.31.1.1.19ColumnspvTddSTddConfigurationread-writecurrentTDDS TDD configuration
1.3.6.1.4.1.6626.6000.4.31.1.1.20ColumnspvTddSTddSpecialSubframeread-writecurrentTDDS TDD special subframe
1.3.6.1.4.1.6626.6000.4.31.1.1.21ColumnspvTddSTddSpecialSubframe1read-onlycurrentTDDS TDD special subframe
1.3.6.1.4.1.6626.6000.4.31.1.1.22ColumnspvTddSTddDetectionModeread-onlycurrentTDDS TDD detect mode
1.3.6.1.4.1.6626.6000.4.31.1.1.23ColumnspvTddSDeviceResetread-writecurrentTDD Device Reset
1.3.6.1.4.1.6626.6000.4.31.1.1.24ColumnspvTddSPolarity1read-onlycurrentTDDS Polarity 1
1.3.6.1.4.1.6626.6000.4.31.1.1.25ColumnspvTddSPolarity2read-onlycurrentTDDS Polarity 2
1.3.6.1.4.1.6626.6000.4.31.1.1.26ColumnspvTddSSearchStartLevelread-writecurrentTDDS Search start level
1.3.6.1.4.1.6626.6000.4.31.2TablespvTddSChTablenot-accessiblecurrentTDDS receivers table
1.3.6.1.4.1.6626.6000.4.31.2.1RowspvTddSChEntrynot-accessiblecurrentTDDS receivers table entry
1.3.6.1.4.1.6626.6000.4.31.2.1.1ColumnspvTddSChIndexnot-accessiblecurrentTDDS receiver index
1.3.6.1.4.1.6626.6000.4.31.2.1.2ColumnspvTddSChAttUserread-writecurrentAttenuation user of channel (dB)
1.3.6.1.4.1.6626.6000.4.31.3NodespvTddSAlarm
1.3.6.1.4.1.6626.6000.4.31.3.1TablespvTddSAlarmGlobalTablenot-accessiblecurrentTDDS alarms global table
1.3.6.1.4.1.6626.6000.4.31.3.1.1RowspvTddSAlarmGlobalEntrynot-accessiblecurrentTDDS alarms global table entry
1.3.6.1.4.1.6626.6000.4.31.3.1.1.1ColumnspvTddSAlarmGlobalCountread-onlycurrentTDDS alarms global count
1.3.6.1.4.1.6626.6000.4.31.3.1.1.2ColumnspvTddSAlarmMaxSeverityread-onlycurrentTDDS alarms max severity
1.3.6.1.4.1.6626.6000.4.31.3.1.1.3ColumnspvTddSReachableread-onlycurrentTDDS reachable
1.3.6.1.4.1.6626.6000.4.31.3.2TablespvTddSAlarmTablenot-accessiblecurrentTDDS alarms table
1.3.6.1.4.1.6626.6000.4.31.3.2.1RowspvTddSAlarmEntrynot-accessiblecurrentTDDS alarms table entry
1.3.6.1.4.1.6626.6000.4.31.3.2.1.1ColumnspvTddSAlarmTypenot-accessiblecurrentTDDS alarm type
1.3.6.1.4.1.6626.6000.4.31.3.2.1.2ColumnspvTddSAlarmEnableread-writecurrentTDDS alarm enable
1.3.6.1.4.1.6626.6000.4.31.3.2.1.3ColumnspvTddSAlarmStateread-onlycurrentTDDS alarm state
1.3.6.1.4.1.6626.6000.4.31.3.2.1.4ColumnspvTddSAlarmSeverityread-onlycurrentTDDS alarm severity
1.3.6.1.4.1.6626.6000.4.31.3.2.1.5ColumnspvTddSAlarmPolarityread-onlycurrentTDDS alarm polarity
1.3.6.1.4.1.6626.6000.4.31.3.2.1.6ColumnspvTddSAlarmNameread-onlycurrentTDDS alarm name
1.3.6.1.4.1.6626.6000.4.32NodespvTddu
1.3.6.1.4.1.6626.6000.4.32.1TablespvTdduTablenot-accessiblecurrentTDDU table
1.3.6.1.4.1.6626.6000.4.32.1.1RowspvTdduEntrynot-accessiblecurrentTDDU table entry
1.3.6.1.4.1.6626.6000.4.32.1.1.1ColumnspvTdduIndexnot-accessiblecurrentTDDU table index
1.3.6.1.4.1.6626.6000.4.32.1.1.2ColumnspvTdduTyperead-onlycurrentTDDU type
1.3.6.1.4.1.6626.6000.4.32.1.1.3ColumnspvTdduModelread-onlycurrentTDDU model
1.3.6.1.4.1.6626.6000.4.32.1.1.4ColumnspvTdduCommercialCoderead-onlycurrentTDDU sale code
1.3.6.1.4.1.6626.6000.4.32.1.1.5ColumnspvTdduCommercialDescriptionread-onlycurrentTDDU sale description
1.3.6.1.4.1.6626.6000.4.32.1.1.6ColumnspvTdduVersionread-onlycurrentTDDU version
1.3.6.1.4.1.6626.6000.4.32.1.1.7ColumnspvTdduSerialNumberread-onlycurrentTDDU serial number
1.3.6.1.4.1.6626.6000.4.32.1.1.8ColumnspvTdduProductionDateread-onlycurrentTDDU production date
1.3.6.1.4.1.6626.6000.4.32.1.1.9ColumnspvTdduCommissionDateread-writecurrentTDDU commissioning date
1.3.6.1.4.1.6626.6000.4.32.1.1.10ColumnspvTdduTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.32.1.1.11ColumnspvTdduVendorIdread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.32.1.1.12ColumnspvTdduDataTimestampread-onlycurrentTDDU production date
1.3.6.1.4.1.6626.6000.4.32.1.1.13ColumnspvTdduDataSourceread-writecurrentTDDU table index
1.3.6.1.4.1.6626.6000.4.32.1.1.14ColumnspvTdduDataRestoreread-writecurrentTDDU table index
1.3.6.1.4.1.6626.6000.4.32.1.1.15ColumnspvTdduTemperatureread-onlycurrentTDDU temperature in (C)
1.3.6.1.4.1.6626.6000.4.32.1.1.16ColumnspvTdduV28vread-onlycurrentTDDU Vout in Volt
1.3.6.1.4.1.6626.6000.4.32.1.1.17ColumnspvTdduCur28vread-onlycurrentTDDU current in mA
1.3.6.1.4.1.6626.6000.4.32.1.1.18ColumnspvTdduRfPwrread-onlycurrentTDDU current in mA
1.3.6.1.4.1.6626.6000.4.32.1.1.19ColumnspvTdduVcoVoltageread-onlycurrentTDDU current in mA
1.3.6.1.4.1.6626.6000.4.32.1.1.20ColumnspvTdduSelMAread-writecurrentTDDU selector Manual-Automatic
1.3.6.1.4.1.6626.6000.4.32.1.1.21ColumnspvTdduSelUlDlread-writecurrentTDDU selector Manual-Automatic
1.3.6.1.4.1.6626.6000.4.32.2NodespvTdduAlarm
1.3.6.1.4.1.6626.6000.4.32.2.1TablespvTdduAlarmGlobalTablenot-accessiblecurrentTDDU alarms global table
1.3.6.1.4.1.6626.6000.4.32.2.1.1RowspvTdduAlarmGlobalEntrynot-accessiblecurrentTDDU alarms global table entry
1.3.6.1.4.1.6626.6000.4.32.2.1.1.1ColumnspvTdduAlarmGlobalCountread-onlycurrentTDDU alarms global count
1.3.6.1.4.1.6626.6000.4.32.2.1.1.2ColumnspvTdduAlarmMaxSeverityread-onlycurrentTDDU alarms max severity
1.3.6.1.4.1.6626.6000.4.32.2.1.1.3ColumnspvTdduReachableread-onlycurrentTDDU reachable
1.3.6.1.4.1.6626.6000.4.32.2.2TablespvTdduAlarmTablenot-accessiblecurrentTDDU alarms table
1.3.6.1.4.1.6626.6000.4.32.2.2.1RowspvTdduAlarmEntrynot-accessiblecurrentTDDU alarms table entry
1.3.6.1.4.1.6626.6000.4.32.2.2.1.1ColumnspvTdduAlarmTypenot-accessiblecurrentTDDU alarm type
1.3.6.1.4.1.6626.6000.4.32.2.2.1.2ColumnspvTdduAlarmEnableread-writecurrentTDDU alarm enable
1.3.6.1.4.1.6626.6000.4.32.2.2.1.3ColumnspvTdduAlarmStateread-onlycurrentTDDU alarm state
1.3.6.1.4.1.6626.6000.4.32.2.2.1.4ColumnspvTdduAlarmSeverityread-writecurrentTDDU alarm severity
1.3.6.1.4.1.6626.6000.4.32.2.2.1.5ColumnspvTdduAlarmPolarityread-writecurrentTDDU alarm polarity
1.3.6.1.4.1.6626.6000.4.32.2.2.1.6ColumnspvTdduAlarmNameread-writecurrentTDDU alarm name
1.3.6.1.4.1.6626.6000.4.33NodespvLDas
1.3.6.1.4.1.6626.6000.4.33.1TablespvLDasTablenot-accessiblecurrentLDas table
1.3.6.1.4.1.6626.6000.4.33.1.1RowspvLDasEntrynot-accessiblecurrentLDas table entry
1.3.6.1.4.1.6626.6000.4.33.1.1.1ColumnspvLDasIndexnot-accessiblecurrentLDas index
1.3.6.1.4.1.6626.6000.4.33.1.1.2ColumnspvLDasTyperead-onlycurrentLDas type
1.3.6.1.4.1.6626.6000.4.33.1.1.3ColumnspvLDasModelread-onlycurrentLDas model
1.3.6.1.4.1.6626.6000.4.33.1.1.4ColumnspvLDasCommercialCoderead-onlycurrentLDas sale code
1.3.6.1.4.1.6626.6000.4.33.1.1.5ColumnspvLDasCommercialDescriptionread-onlycurrentLDas sale description
1.3.6.1.4.1.6626.6000.4.33.1.1.6ColumnspvLDasVersionread-onlycurrentLDas version
1.3.6.1.4.1.6626.6000.4.33.1.1.7ColumnspvLDasSerialNumberread-onlycurrentLDas serial number
1.3.6.1.4.1.6626.6000.4.33.1.1.8ColumnspvLDasProductionDateread-onlycurrentLDas production date
1.3.6.1.4.1.6626.6000.4.33.1.1.9ColumnspvLDasCommissionDateread-writecurrentLDas commissioning date
1.3.6.1.4.1.6626.6000.4.33.1.1.10ColumnspvLDasVendorIdread-writecurrentLDas Name, max 30 char
1.3.6.1.4.1.6626.6000.4.33.1.1.11ColumnspvLDasTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.33.1.1.12ColumnspvLDasDataTimestampread-onlycurrentLDas production date
1.3.6.1.4.1.6626.6000.4.33.1.1.13ColumnspvLDasDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.33.1.1.14ColumnspvLDasDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.33.1.1.15ColumnspvLDasNameread-writecurrentLDas Name, max 30 char
1.3.6.1.4.1.6626.6000.4.33.1.1.16ColumnspvLDasTemperatureread-onlycurrentLDas temperature in (C)
1.3.6.1.4.1.6626.6000.4.33.1.1.17ColumnspvLDasPwrAlarmHysteresisread-writecurrentLDas power hysteresis
1.3.6.1.4.1.6626.6000.4.33.1.1.18ColumnspvLDasPwrLimiterread-writecurrentLDas power limiter menu
1.3.6.1.4.1.6626.6000.4.33.1.1.19ColumnspvLDasPwrLimiterModeread-writecurrentLDas power limiter mode menu
1.3.6.1.4.1.6626.6000.4.33.2TablespvLDasChTablenot-accessiblecurrentLDas alarms table
1.3.6.1.4.1.6626.6000.4.33.2.1RowspvLDasChEntrynot-accessiblecurrentLDas alarms table entry
1.3.6.1.4.1.6626.6000.4.33.2.1.1ColumnspvLDasChIndexnot-accessiblecurrentLDas attenuation (dB)
1.3.6.1.4.1.6626.6000.4.33.2.1.2ColumnspvLDasAttMecDlread-writecurrentLDas attenuation (dB)
1.3.6.1.4.1.6626.6000.4.33.2.1.3ColumnspvLDasAttDigDlread-writecurrentLDas attenuation (dB)
1.3.6.1.4.1.6626.6000.4.33.2.1.4ColumnspvLDasRmsPwrDlread-onlycurrentLDas RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.33.2.1.5ColumnspvLDasPeakPwrDlread-onlycurrentLDas peak power (dBm)
1.3.6.1.4.1.6626.6000.4.33.2.1.6ColumnspvLDasThrMinRmsPwrDlread-writecurrentLDas RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.33.2.1.7ColumnspvLDasThrMaxRmsPwrDlread-writecurrentLDas RMS Power (dBm)
1.3.6.1.4.1.6626.6000.4.33.2.1.8ColumnspvLDasThrMaxPeakPwrDlread-writecurrentLDas peak power (dBm)
1.3.6.1.4.1.6626.6000.4.33.2.1.9ColumnspvLDasAttDigUlread-writecurrentLDas attenuation (dB)
1.3.6.1.4.1.6626.6000.4.33.2.1.10ColumnspvLDasSwitchLnaread-writecurrentSwitch LNA enable
1.3.6.1.4.1.6626.6000.4.33.2.1.11ColumnspvLDasClearOverdriveread-writecurrentClear Overdrive on the specified channel
1.3.6.1.4.1.6626.6000.4.33.2.1.12ColumnspvLDasRfOffread-writecurrentClear Overdrive on the specified channel
1.3.6.1.4.1.6626.6000.4.33.2.1.13ColumnspvLDasPAEnableread-writecurrentPower Amplifier enable
1.3.6.1.4.1.6626.6000.4.33.2.1.14ColumnspvLDasDAEnableread-writecurrentDriver Amplifier enable
1.3.6.1.4.1.6626.6000.4.33.3NodespvLDasAlarm
1.3.6.1.4.1.6626.6000.4.33.3.1TablespvLDasAlarmGlobalTablenot-accessiblecurrentLDas alarms global table
1.3.6.1.4.1.6626.6000.4.33.3.1.1RowspvLDasAlarmGlobalEntrynot-accessiblecurrentLDas alarms global table entry
1.3.6.1.4.1.6626.6000.4.33.3.1.1.1ColumnspvLDasAlarmGlobalCountread-onlycurrentLDas alarms global count
1.3.6.1.4.1.6626.6000.4.33.3.1.1.2ColumnspvLDasAlarmMaxSeverityread-onlycurrentLDas alarms max severity
1.3.6.1.4.1.6626.6000.4.33.3.1.1.3ColumnspvLDasReachableread-onlycurrentLDas reachable
1.3.6.1.4.1.6626.6000.4.33.3.2TablespvLDasAlarmTablenot-accessiblecurrentLDas alarms table
1.3.6.1.4.1.6626.6000.4.33.3.2.1RowspvLDasAlarmEntrynot-accessiblecurrentLDas alarms table entry
1.3.6.1.4.1.6626.6000.4.33.3.2.1.1ColumnspvLDasAlarmTypenot-accessiblecurrentLDas alarm type
1.3.6.1.4.1.6626.6000.4.33.3.2.1.2ColumnspvLDasAlarmEnableread-writecurrentLDas alarm enable
1.3.6.1.4.1.6626.6000.4.33.3.2.1.3ColumnspvLDasAlarmStateread-onlycurrentLDas alarm state
1.3.6.1.4.1.6626.6000.4.33.3.2.1.4ColumnspvLDasAlarmSeverityread-onlycurrentLDas alarm severity
1.3.6.1.4.1.6626.6000.4.33.3.2.1.5ColumnspvLDasAlarmPolarityread-onlycurrentLDas alarm polarity
1.3.6.1.4.1.6626.6000.4.33.3.2.1.6ColumnspvLDasAlarmNameread-onlycurrentLDas alarm name
1.3.6.1.4.1.6626.6000.4.34NodespvPoiCpri
1.3.6.1.4.1.6626.6000.4.34.1TablespvPoiCpriTablenot-accessiblecurrentPOI-CPRI table
1.3.6.1.4.1.6626.6000.4.34.1.1RowspvPoiCpriEntrynot-accessiblecurrentPOI-CPRI table entry
1.3.6.1.4.1.6626.6000.4.34.1.1.1ColumnspvPoiCpriIndexnot-accessiblecurrentPOI-CPRI index
1.3.6.1.4.1.6626.6000.4.34.1.1.2ColumnspvPoiCpriTyperead-onlycurrentPOI-CPRI type
1.3.6.1.4.1.6626.6000.4.34.1.1.3ColumnspvPoiCpriModelread-onlycurrentPOI-CPRI model
1.3.6.1.4.1.6626.6000.4.34.1.1.4ColumnspvPoiCpriCommercialCoderead-onlycurrentPOI-CPRI sale code
1.3.6.1.4.1.6626.6000.4.34.1.1.5ColumnspvPoiCpriCommercialDescriptionread-onlycurrentPOI-CPRI sale description
1.3.6.1.4.1.6626.6000.4.34.1.1.6ColumnspvPoiCpriVersionread-onlycurrentPOI-CPRI version
1.3.6.1.4.1.6626.6000.4.34.1.1.7ColumnspvPoiCpriSerialNumberread-onlycurrentPOI-CPRI serial number
1.3.6.1.4.1.6626.6000.4.34.1.1.8ColumnspvPoiCpriProductionDateread-onlycurrentPOI-CPRI production date
1.3.6.1.4.1.6626.6000.4.34.1.1.9ColumnspvPoiCpriCommissionDateread-writecurrentPOI-CPRI commissioning date
1.3.6.1.4.1.6626.6000.4.34.1.1.10ColumnspvPoiCpriTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.34.1.1.11ColumnspvPoiCpriVendorIdread-writecurrentPOI-CPRI Name, max 30 char
1.3.6.1.4.1.6626.6000.4.34.1.1.12ColumnspvPoiCpriDataTimestampread-onlycurrentPOI-CPRI production date
1.3.6.1.4.1.6626.6000.4.34.1.1.13ColumnspvPoiCpriDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.34.1.1.14ColumnspvPoiCpriDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.34.1.1.15ColumnspvPoiCpriTemperatureread-onlycurrentPOI-CPRI temperature in (C)
1.3.6.1.4.1.6626.6000.4.34.1.1.16ColumnspvPoiCpriCur28vread-writecurrentPOI-CPRI cur 28v (mA)
1.3.6.1.4.1.6626.6000.4.34.1.1.17ColumnspvPoiCpriNameread-writecurrentPOI-CPRI Name, max 30 char
1.3.6.1.4.1.6626.6000.4.34.1.1.18ColumnspvPoiCpriNameSystemread-writecurrentPOI-CPRI Name, max 30 char
1.3.6.1.4.1.6626.6000.4.34.1.1.19ColumnspvPoiCpriAttDlCh1read-writecurrentPOI-CPRI attenuation (dB)
1.3.6.1.4.1.6626.6000.4.34.1.1.20ColumnspvPoiCpriAttDlCh2read-writecurrentPOI-CPRI attenuation (dB)
1.3.6.1.4.1.6626.6000.4.34.1.1.21ColumnspvPoiCpriAttUlCh1read-writecurrentPOI-CPRI attenuation (dB)
1.3.6.1.4.1.6626.6000.4.34.1.1.22ColumnspvPoiCpriAttUlCh2read-writecurrentPOI-CPRI attenuation (dB)
1.3.6.1.4.1.6626.6000.4.34.1.1.23ColumnspvPoiCpriPwrOutDlCh1read-onlycurrentPOI-CPRI peak power (dBm)
1.3.6.1.4.1.6626.6000.4.34.1.1.24ColumnspvPoiCpriPwrOutDlCh2read-onlycurrentPOI-CPRI peak power (dBm)
1.3.6.1.4.1.6626.6000.4.34.1.1.25ColumnspvPoiCpriPreAmpUlCh1read-writecurrentPre amp enable 1
1.3.6.1.4.1.6626.6000.4.34.1.1.26ColumnspvPoiCpriPreAmpUlCh2read-writecurrentPre amp enable 1
1.3.6.1.4.1.6626.6000.4.34.1.1.27ColumnspvPoiCpriPaprDlCh1read-onlycurrentpapr dl 1
1.3.6.1.4.1.6626.6000.4.34.1.1.28ColumnspvPoiCpriPaprDlCh2read-onlycurrentpapr dl 1
1.3.6.1.4.1.6626.6000.4.34.1.1.29ColumnspvPoiCpriTypeFpgaread-onlycurrentPOI-CPRI type
1.3.6.1.4.1.6626.6000.4.34.1.1.30ColumnspvPoiCpriModelFpgaread-onlycurrentPOI-CPRI model
1.3.6.1.4.1.6626.6000.4.34.1.1.31ColumnspvPoiCpriVersionHwFpgaread-onlycurrentPOI-CPRI version
1.3.6.1.4.1.6626.6000.4.34.1.1.32ColumnspvPoiCpriVersionSwFpgaread-onlycurrentPOI-CPRI version
1.3.6.1.4.1.6626.6000.4.34.1.1.33ColumnspvPoiCpriHwRevisionFpgaread-onlycurrentPOI-CPRI version
1.3.6.1.4.1.6626.6000.4.34.1.1.34ColumnspvPoiCpriCur28v1Ch1read-onlycurrentPOI-CPRI cur 28v1 Ch1 (mA)
1.3.6.1.4.1.6626.6000.4.34.1.1.35ColumnspvPoiCpriCur28v1Ch2read-onlycurrentPOI-CPRI cur 28v1 Ch1 (mA)
1.3.6.1.4.1.6626.6000.4.34.1.1.36ColumnspvPoiCpriCur28v2Ch1read-onlycurrentPOI-CPRI cur 28v1 Ch1 (mA)
1.3.6.1.4.1.6626.6000.4.34.1.1.37ColumnspvPoiCpriCur28v2Ch2read-onlycurrentPOI-CPRI cur 28v1 Ch1 (mA)
1.3.6.1.4.1.6626.6000.4.34.1.1.38ColumnspvPoiCpriCarriersDlNumberread-onlycurrentPOI-CPRI number of DL carriers handled
1.3.6.1.4.1.6626.6000.4.34.1.1.39ColumnspvPoiCpriCarriersUlNumberread-onlycurrentPOI-CPRI number of UL carriers handled
1.3.6.1.4.1.6626.6000.4.34.2NodespvPoiCpriAlarm
1.3.6.1.4.1.6626.6000.4.34.2.1TablespvPoiCpriAlarmGlobalTablenot-accessiblecurrentPOI-CPRI alarms global table
1.3.6.1.4.1.6626.6000.4.34.2.1.1RowspvPoiCpriAlarmGlobalEntrynot-accessiblecurrentPOI-CPRI alarms global table entry
1.3.6.1.4.1.6626.6000.4.34.2.1.1.1ColumnspvPoiCpriAlarmGlobalCountread-onlycurrentPOI-CPRI alarms global count
1.3.6.1.4.1.6626.6000.4.34.2.1.1.2ColumnspvPoiCpriAlarmMaxSeverityread-onlycurrentPOI-CPRI alarms max severity
1.3.6.1.4.1.6626.6000.4.34.2.1.1.3ColumnspvPoiCpriReachableread-onlycurrentPOI-CPRI reachable
1.3.6.1.4.1.6626.6000.4.34.2.2TablespvPoiCpriAlarmTablenot-accessiblecurrentPOI-CPRI alarms table
1.3.6.1.4.1.6626.6000.4.34.2.2.1RowspvPoiCpriAlarmEntrynot-accessiblecurrentPOI-CPRI alarms table entry
1.3.6.1.4.1.6626.6000.4.34.2.2.1.1ColumnspvPoiCpriAlarmTypenot-accessiblecurrentPOI-CPRI alarm type
1.3.6.1.4.1.6626.6000.4.34.2.2.1.2ColumnspvPoiCpriAlarmEnableread-writecurrentPOI-CPRI alarm enable
1.3.6.1.4.1.6626.6000.4.34.2.2.1.3ColumnspvPoiCpriAlarmStateread-onlycurrentPOI-CPRI alarm state
1.3.6.1.4.1.6626.6000.4.34.2.2.1.4ColumnspvPoiCpriAlarmSeverityread-onlycurrentPOI-CPRI alarm severity
1.3.6.1.4.1.6626.6000.4.34.2.2.1.5ColumnspvPoiCpriAlarmPolarityread-onlycurrentPOI-CPRI alarm polarity
1.3.6.1.4.1.6626.6000.4.34.2.2.1.6ColumnspvPoiCpriAlarmNameread-onlycurrentPOI-CPRI alarm name
1.3.6.1.4.1.6626.6000.4.35NodespvNgOtrx
1.3.6.1.4.1.6626.6000.4.35.1TablespvNgOtrxTablenot-accessiblecurrentNG-OTRX table
1.3.6.1.4.1.6626.6000.4.35.1.1RowspvNgOtrxEntrynot-accessiblecurrentNG-OTRX table entry
1.3.6.1.4.1.6626.6000.4.35.1.1.1ColumnspvNgOtrxIndexnot-accessiblecurrentNG-OTRX index
1.3.6.1.4.1.6626.6000.4.35.1.1.2ColumnspvNgOtrxTyperead-onlycurrentNG-OTRX type
1.3.6.1.4.1.6626.6000.4.35.1.1.3ColumnspvNgOtrxModelread-onlycurrentNG-OTRX model
1.3.6.1.4.1.6626.6000.4.35.1.1.4ColumnspvNgOtrxCommercialCoderead-onlycurrentNG-OTRX sale code
1.3.6.1.4.1.6626.6000.4.35.1.1.5ColumnspvNgOtrxCommercialDescriptionread-onlycurrentNG-OTRX sale description
1.3.6.1.4.1.6626.6000.4.35.1.1.6ColumnspvNgOtrxVersionread-onlycurrentNG-OTRX version
1.3.6.1.4.1.6626.6000.4.35.1.1.7ColumnspvNgOtrxSerialNumberread-onlycurrentNG-OTRX serial number
1.3.6.1.4.1.6626.6000.4.35.1.1.8ColumnspvNgOtrxTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.35.1.1.9ColumnspvNgOtrxDataTimestampread-onlycurrentNG-OTRX production date
1.3.6.1.4.1.6626.6000.4.35.1.1.10ColumnspvNgOtrxDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.35.1.1.11ColumnspvNgOtrxDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.35.1.1.12ColumnspvNgOtrxTmpBoardRfread-onlycurrentNG-OTRX temperature in (C)
1.3.6.1.4.1.6626.6000.4.35.1.1.13ColumnspvNgOtrxTmpCoreread-onlycurrentNG-OTRX temperature in (C)
1.3.6.1.4.1.6626.6000.4.35.1.1.14ColumnspvNgOtrxFanSpeed1read-onlycurrentNG-OTRX fan speed 1
1.3.6.1.4.1.6626.6000.4.35.1.1.15ColumnspvNgOtrxFanSpeed2read-onlycurrentNG-OTRX fan speed 2
1.3.6.1.4.1.6626.6000.4.35.1.1.16ColumnspvNgOtrxRfPortMappingread-writecurrentNG-OTRX RF Port Mapping
1.3.6.1.4.1.6626.6000.4.35.1.1.17ColumnspvNgOtrxFecFeatureEnread-onlycurrentNG-OTRX DWDM feature enable
1.3.6.1.4.1.6626.6000.4.35.1.1.18ColumnspvNgOtrxFecCommandMainread-writecurrentNG-OTRX DWDM enable
1.3.6.1.4.1.6626.6000.4.35.1.1.19ColumnspvNgOtrxTsyncActiveSelectorread-onlycurrentActive TSYNC selector
1.3.6.1.4.1.6626.6000.4.35.1.1.20ColumnspvNgOtrxTsyncActiveread-onlycurrentActive TSYNC
1.3.6.1.4.1.6626.6000.4.35.1.1.21ColumnspvNgOtrxTsyncRfConfigMainread-onlycurrentTSYNC main configuration
1.3.6.1.4.1.6626.6000.4.35.1.1.22ColumnspvNgOtrxTsyncRfConfigSecondaryread-onlycurrentTSYNC secondary configuration
1.3.6.1.4.1.6626.6000.4.35.2TablespvNgOtrxChTablenot-accessiblecurrentNG-OTRX channels table
1.3.6.1.4.1.6626.6000.4.35.2.1RowspvNgOtrxChEntrynot-accessiblecurrentNG-OTRX channels table entry
1.3.6.1.4.1.6626.6000.4.35.2.1.1ColumnspvNgOtrxChIndexnot-accessiblecurrentindex of the channel
1.3.6.1.4.1.6626.6000.4.35.2.1.2ColumnspvNgOtrxConnectorSfpChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.35.2.1.3ColumnspvNgOtrxTmpSfpChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.35.2.1.4ColumnspvNgOtrxAttUserTxChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.35.2.1.5ColumnspvNgOtrxAttUserRxChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.35.2.1.6ColumnspvNgOtrxPwrTxSfpChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.35.2.1.7ColumnspvNgOtrxPwrRxSfpChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.35.2.1.8ColumnspvNgOtrxFecCommandSfpread-writecurrentDWDM Link enable
1.3.6.1.4.1.6626.6000.4.35.3NodespvNgOtrxAlarm
1.3.6.1.4.1.6626.6000.4.35.3.1TablespvNgOtrxAlarmGlobalTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.35.3.1.1RowspvNgOtrxAlarmGlobalEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.35.3.1.1.1ColumnspvNgOtrxAlarmGlobalCountread-onlycurrentNG-OTRX alarms global count
1.3.6.1.4.1.6626.6000.4.35.3.1.1.2ColumnspvNgOtrxAlarmMaxSeverityread-onlycurrentNG-OTRX alarms max severity
1.3.6.1.4.1.6626.6000.4.35.3.1.1.3ColumnspvNgOtrxReachableread-onlycurrentNG-OTRX reachable
1.3.6.1.4.1.6626.6000.4.35.3.2TablespvNgOtrxAlarmTablenot-accessiblecurrentNG-OTRX alarms table
1.3.6.1.4.1.6626.6000.4.35.3.2.1RowspvNgOtrxAlarmEntrynot-accessiblecurrentNG-OTRX alarms table entry
1.3.6.1.4.1.6626.6000.4.35.3.2.1.1ColumnspvNgOtrxAlarmTypenot-accessiblecurrentNG-OTRX alarm type
1.3.6.1.4.1.6626.6000.4.35.3.2.1.2ColumnspvNgOtrxAlarmEnableread-writecurrentNG-OTRX alarm enable
1.3.6.1.4.1.6626.6000.4.35.3.2.1.3ColumnspvNgOtrxAlarmStateread-onlycurrentNG-OTRX alarm state
1.3.6.1.4.1.6626.6000.4.35.3.2.1.4ColumnspvNgOtrxAlarmSeverityread-onlycurrentNG-OTRX alarm severity
1.3.6.1.4.1.6626.6000.4.35.3.2.1.5ColumnspvNgOtrxAlarmPolarityread-onlycurrentNG-OTRX alarm polarity
1.3.6.1.4.1.6626.6000.4.35.3.2.1.6ColumnspvNgOtrxAlarmNameread-onlycurrentNG-OTRX alarm name
1.3.6.1.4.1.6626.6000.4.35.4TablespvNgOtrxTsyncChTablenot-accessiblecurrentNG-OTRX tsync channels table
1.3.6.1.4.1.6626.6000.4.35.4.1RowspvNgOtrxTsyncChEntrynot-accessiblecurrentNG-OTRX tsync channels table entry
1.3.6.1.4.1.6626.6000.4.35.4.1.1ColumnspvNgOtrxTsyncChIndexnot-accessiblecurrentindex of the tsync channel
1.3.6.1.4.1.6626.6000.4.35.4.1.2ColumnspvNgOtrxTddCCPwrread-onlycurrentCC power
1.3.6.1.4.1.6626.6000.4.35.4.1.3ColumnspvNgOtrxTddBandwidthread-onlycurrentBandwidth
1.3.6.1.4.1.6626.6000.4.35.4.1.4ColumnspvNgOtrxTddCarrierFreqread-onlycurrentCarrier Frequency
1.3.6.1.4.1.6626.6000.4.35.4.1.5ColumnspvNgOtrxTddSsbCenterFrequencyKnownread-onlycurrentSSB position
1.3.6.1.4.1.6626.6000.4.35.4.1.6ColumnspvNgOtrxTddSsbCenterFrequencyread-onlycurrentSSb filter width
1.3.6.1.4.1.6626.6000.4.35.4.1.7ColumnspvNgOtrxTddCfgScsIndexread-onlycurrentSubcarrier spacing
1.3.6.1.4.1.6626.6000.4.35.4.1.8ColumnspvNgOtrxTddHoldoverMinread-onlycurrentHoldover minutes
1.3.6.1.4.1.6626.6000.4.35.4.1.9ColumnspvNgOtrxTddPeriodPattern1read-onlycurrentDL/UL pattern 1 duration
1.3.6.1.4.1.6626.6000.4.35.4.1.10ColumnspvNgOtrxTddPeriodPattern2read-onlycurrentDL/UL pattern 2 duration
1.3.6.1.4.1.6626.6000.4.35.4.1.11ColumnspvNgOtrxTddNbrDlSlots1read-onlycurrentNbr of DL slots pattern 1
1.3.6.1.4.1.6626.6000.4.35.4.1.12ColumnspvNgOtrxTddNbrDlSlots2read-onlycurrentNbr of DL slots pattern 2
1.3.6.1.4.1.6626.6000.4.35.4.1.13ColumnspvNgOtrxTddNbrDlSymbols1read-onlycurrentNbr of DL symbols pattern 1
1.3.6.1.4.1.6626.6000.4.35.4.1.14ColumnspvNgOtrxTddNbrDlSymbols2read-onlycurrentNbr of DL symbols pattern 2
1.3.6.1.4.1.6626.6000.4.35.4.1.15ColumnspvNgOtrxTddEnablePattern2read-onlycurrentPort
1.3.6.1.4.1.6626.6000.4.35.4.1.16ColumnspvNgOtrxTsyncRfConfread-onlycurrentPort
1.3.6.1.4.1.6626.6000.4.35.4.1.17ColumnspvNgOtrxTdd5gSaread-onlycurrent5G.SA
1.3.6.1.4.1.6626.6000.4.35.4.1.18ColumnspvNgOtrxTddNbrFSymbols1read-onlycurrentF symbols pattern 1
1.3.6.1.4.1.6626.6000.4.35.4.1.19ColumnspvNgOtrxTddNbrFSymbols2read-onlycurrentF symbols pattern 2
1.3.6.1.4.1.6626.6000.4.36NodespvNgPtp
1.3.6.1.4.1.6626.6000.4.36.1TablespvNgPtpTablenot-accessiblecurrentNG-PtoP table
1.3.6.1.4.1.6626.6000.4.36.1.1RowspvNgPtpEntrynot-accessiblecurrentNG-PtoP table entry
1.3.6.1.4.1.6626.6000.4.36.1.1.1ColumnspvNgPtpIndexnot-accessiblecurrentNG-PtoP index
1.3.6.1.4.1.6626.6000.4.36.1.1.2ColumnspvNgPtpTyperead-onlycurrentNG-PtoP type
1.3.6.1.4.1.6626.6000.4.36.1.1.3ColumnspvNgPtpModelread-onlycurrentNG-PtoP model
1.3.6.1.4.1.6626.6000.4.36.1.1.4ColumnspvNgPtpCommercialCoderead-onlycurrentNG-PtoP sale code
1.3.6.1.4.1.6626.6000.4.36.1.1.5ColumnspvNgPtpCommercialDescriptionread-onlycurrentNG-PtoP sale description
1.3.6.1.4.1.6626.6000.4.36.1.1.6ColumnspvNgPtpVersionread-onlycurrentNG-PtoP version
1.3.6.1.4.1.6626.6000.4.36.1.1.7ColumnspvNgPtpSerialNumberread-onlycurrentNG-PtoP serial number
1.3.6.1.4.1.6626.6000.4.36.1.1.8ColumnspvNgPtpTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.36.1.1.9ColumnspvNgPtpDataTimestampread-onlycurrentNG-PtoP production date
1.3.6.1.4.1.6626.6000.4.36.1.1.10ColumnspvNgPtpDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.36.1.1.11ColumnspvNgPtpDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.36.1.1.12ColumnspvNgPtpTmpBoardRfread-onlycurrentNG-PtoP temperature in (C)
1.3.6.1.4.1.6626.6000.4.36.1.1.13ColumnspvNgPtpTmpCoreread-onlycurrentNG-PtoP temperature in (C)
1.3.6.1.4.1.6626.6000.4.36.1.1.14ColumnspvNgPtpFanSpeed1read-onlycurrentNG-PtoP fan speed 1
1.3.6.1.4.1.6626.6000.4.36.1.1.15ColumnspvNgPtpFanSpeed2read-onlycurrentNG-PtoP fan speed 2
1.3.6.1.4.1.6626.6000.4.36.1.1.16ColumnspvNgPtpNameread-writecurrentNG-PtoP name
1.3.6.1.4.1.6626.6000.4.36.1.1.17ColumnspvNgPtpDescriptionread-writecurrentNG-PtoP description
1.3.6.1.4.1.6626.6000.4.36.1.1.18ColumnspvNgPtpTsyncActiveSelectorread-onlycurrentActive TSYNC selector
1.3.6.1.4.1.6626.6000.4.36.1.1.19ColumnspvNgPtpTsyncActiveread-onlycurrentActive TSYNC
1.3.6.1.4.1.6626.6000.4.36.1.1.20ColumnspvNgPtpTsyncRfConfigMainread-onlycurrentTSYNC main configuration
1.3.6.1.4.1.6626.6000.4.36.1.1.21ColumnspvNgPtpTsyncRfConfigSecondaryread-onlycurrentTSYNC secondary configuration
1.3.6.1.4.1.6626.6000.4.36.2TablespvNgPtpChTablenot-accessiblecurrentNG-PtoP channels table
1.3.6.1.4.1.6626.6000.4.36.2.1RowspvNgPtpChEntrynot-accessiblecurrentNG-PtoP channels table entry
1.3.6.1.4.1.6626.6000.4.36.2.1.1ColumnspvNgPtpChIndexnot-accessiblecurrentindex of the channel
1.3.6.1.4.1.6626.6000.4.36.2.1.2ColumnspvNgPtpConnectorSfpChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.36.2.1.3ColumnspvNgPtpTmpSfpChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.36.2.1.4ColumnspvNgPtpAttUserTxChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.36.2.1.5ColumnspvNgPtpAttUserRxChread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.36.2.1.6ColumnspvNgPtpPwrTxSfpChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.36.2.1.7ColumnspvNgPtpPwrRxSfpChread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.36.3NodespvNgPtpAlarm
1.3.6.1.4.1.6626.6000.4.36.3.1TablespvNgPtpAlarmGlobalTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.36.3.1.1RowspvNgPtpAlarmGlobalEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.36.3.1.1.1ColumnspvNgPtpAlarmGlobalCountread-onlycurrentNG-PtoP alarms global count
1.3.6.1.4.1.6626.6000.4.36.3.1.1.2ColumnspvNgPtpAlarmMaxSeverityread-onlycurrentNG-PtoP alarms max severity
1.3.6.1.4.1.6626.6000.4.36.3.1.1.3ColumnspvNgPtpReachableread-onlycurrentNG-PtoP reachable
1.3.6.1.4.1.6626.6000.4.36.3.2TablespvNgPtpAlarmTablenot-accessiblecurrentNG-PtoP alarms table
1.3.6.1.4.1.6626.6000.4.36.3.2.1RowspvNgPtpAlarmEntrynot-accessiblecurrentNG-PtoP alarms table entry
1.3.6.1.4.1.6626.6000.4.36.3.2.1.1ColumnspvNgPtpAlarmTypenot-accessiblecurrentNG-PtoP alarm type
1.3.6.1.4.1.6626.6000.4.36.3.2.1.2ColumnspvNgPtpAlarmEnableread-writecurrentNG-PtoP alarm enable
1.3.6.1.4.1.6626.6000.4.36.3.2.1.3ColumnspvNgPtpAlarmStateread-onlycurrentNG-PtoP alarm state
1.3.6.1.4.1.6626.6000.4.36.3.2.1.4ColumnspvNgPtpAlarmSeverityread-onlycurrentNG-PtoP alarm severity
1.3.6.1.4.1.6626.6000.4.36.3.2.1.5ColumnspvNgPtpAlarmPolarityread-onlycurrentNG-PtoP alarm polarity
1.3.6.1.4.1.6626.6000.4.36.3.2.1.6ColumnspvNgPtpAlarmNameread-onlycurrentNG-PtoP alarm name
1.3.6.1.4.1.6626.6000.4.36.4TablespvNgPtpTsyncChTablenot-accessiblecurrentNG-OTRX tsync channels table
1.3.6.1.4.1.6626.6000.4.36.4.1RowspvNgPtpTsyncChEntrynot-accessiblecurrentNG-OTRX tsync channels table entry
1.3.6.1.4.1.6626.6000.4.36.4.1.1ColumnspvNgPtpTsyncChIndexnot-accessiblecurrentindex of the tsync channel
1.3.6.1.4.1.6626.6000.4.36.4.1.2ColumnspvNgPtpTddCCPwrread-onlycurrentCC power
1.3.6.1.4.1.6626.6000.4.36.4.1.3ColumnspvNgPtpTddBandwidthread-onlycurrentBandwidth
1.3.6.1.4.1.6626.6000.4.36.4.1.4ColumnspvNgPtpTddCarrierFreqread-onlycurrentCarrier Frequency
1.3.6.1.4.1.6626.6000.4.36.4.1.5ColumnspvNgPtpTddSsbCenterFrequencyKnownread-onlycurrentSSB position
1.3.6.1.4.1.6626.6000.4.36.4.1.6ColumnspvNgPtpTddSsbCenterFrequencyread-onlycurrentSSb filter width
1.3.6.1.4.1.6626.6000.4.36.4.1.7ColumnspvNgPtpTddCfgScsIndexread-onlycurrentSubcarrier spacing
1.3.6.1.4.1.6626.6000.4.36.4.1.8ColumnspvNgPtpTddHoldoverMinread-onlycurrentHoldover minutes
1.3.6.1.4.1.6626.6000.4.36.4.1.9ColumnspvNgPtpTddPeriodPattern1read-onlycurrentDL/UL pattern 1 duration
1.3.6.1.4.1.6626.6000.4.36.4.1.10ColumnspvNgPtpTddPeriodPattern2read-onlycurrentDL/UL pattern 2 duration
1.3.6.1.4.1.6626.6000.4.36.4.1.11ColumnspvNgPtpTddNbrDlSlots1read-onlycurrentNbr of DL slots pattern 1
1.3.6.1.4.1.6626.6000.4.36.4.1.12ColumnspvNgPtpTddNbrDlSlots2read-onlycurrentNbr of DL slots pattern 2
1.3.6.1.4.1.6626.6000.4.36.4.1.13ColumnspvNgPtpTddNbrDlSymbols1read-onlycurrentNbr of DL symbols pattern 1
1.3.6.1.4.1.6626.6000.4.36.4.1.14ColumnspvNgPtpTddNbrDlSymbols2read-onlycurrentNbr of DL symbols pattern 2
1.3.6.1.4.1.6626.6000.4.36.4.1.15ColumnspvNgPtpTddEnablePattern2read-onlycurrentNbr of DL symbols pattern 2
1.3.6.1.4.1.6626.6000.4.36.4.1.16ColumnspvNgPtpTsyncRfConfread-onlycurrentPort
1.3.6.1.4.1.6626.6000.4.36.4.1.17ColumnspvNgPtpTdd5gSaread-onlycurrent5G.SA
1.3.6.1.4.1.6626.6000.4.36.4.1.18ColumnspvNgPtpTddNbrFSymbols1read-onlycurrentF symbols pattern 1
1.3.6.1.4.1.6626.6000.4.36.4.1.19ColumnspvNgPtpTddNbrFSymbols2read-onlycurrentF symbols pattern 2
1.3.6.1.4.1.6626.6000.4.37NodespvNgRu1b
1.3.6.1.4.1.6626.6000.4.37.1TablespvNgRu1bTablenot-accessiblecurrent
1.3.6.1.4.1.6626.6000.4.37.1.1RowspvNgRu1bEntrynot-accessiblecurrent
1.3.6.1.4.1.6626.6000.4.37.1.1.1ColumnspvNgRu1bIndexnot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.2ColumnspvNgRu1bTyperead-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.3ColumnspvNgRu1bModelread-onlycurrent
1.3.6.1.4.1.6626.6000.4.37.1.1.4ColumnspvNgRu1bCommercialCoderead-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.5ColumnspvNgRu1bCommercialDescriptionread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.6ColumnspvNgRu1bVersionread-onlycurrent
1.3.6.1.4.1.6626.6000.4.37.1.1.7ColumnspvNgRu1bSerialNumberread-onlycurrent
1.3.6.1.4.1.6626.6000.4.37.1.1.8ColumnspvNgRu1bTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.37.1.1.9ColumnspvNgRu1bDataTimestampread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.10ColumnspvNgRu1bDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.37.1.1.11ColumnspvNgRu1bDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.37.1.1.12ColumnspvNgRu1bNameread-writecurrent
1.3.6.1.4.1.6626.6000.4.37.1.1.13ColumnspvNgRu1bDescriptionread-writecurrent
1.3.6.1.4.1.6626.6000.4.37.1.1.14ColumnspvNgRu1bTmpRfBoardread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.15ColumnspvNgRu1bTmpCoreread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.16ColumnspvNgRu1bSfpTemperatureread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.17ColumnspvNgRu1bOptPwrTxread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.18ColumnspvNgRu1bOptPwrRxread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.1.1.19ColumnspvNgRu1bRuAddressread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.37.1.1.20ColumnspvNgRu1bFanSpeed1read-onlycurrentFan speed in rpm
1.3.6.1.4.1.6626.6000.4.37.1.1.21ColumnspvNgRu1bFanSpeed2read-onlycurrentFan speed in rpm
1.3.6.1.4.1.6626.6000.4.37.1.1.22ColumnspvNgRu1bFanSpeed3read-onlycurrentFan speed in rpm
1.3.6.1.4.1.6626.6000.4.37.1.1.23ColumnspvNgRu1bFanSpeed4read-onlycurrentFan speed in rpm
1.3.6.1.4.1.6626.6000.4.37.1.1.24ColumnspvNgRu1bResetread-writecurrentreset the board
1.3.6.1.4.1.6626.6000.4.37.2NodespvNgRu1bAlarm
1.3.6.1.4.1.6626.6000.4.37.2.1TablespvNgRu1bAlarmGlobalTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.1.1RowspvNgRu1bAlarmGlobalEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.1.1.1ColumnspvNgRu1bAlarmGlobalCountread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.1.1.2ColumnspvNgRu1bAlarmMaxSeverityread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.1.1.3ColumnspvNgRu1bReachableread-onlycurrentmodule reachable or not.
1.3.6.1.4.1.6626.6000.4.37.2.2TablespvNgRu1bAlarmTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.2.1RowspvNgRu1bAlarmEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.2.1.1ColumnspvNgRu1bAlarmTypenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.2.1.2ColumnspvNgRu1bAlarmEnableread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.2.1.3ColumnspvNgRu1bAlarmStateread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.2.1.4ColumnspvNgRu1bAlarmSeverityread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.2.1.5ColumnspvNgRu1bAlarmPolarityread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.37.2.2.1.6ColumnspvNgRu1bAlarmNameread-writecurrentalarm name.
1.3.6.1.4.1.6626.6000.4.37.3TablespvNgRu1bChTablenot-accessiblecurrentNG-RU 1B channels table
1.3.6.1.4.1.6626.6000.4.37.3.1RowspvNgRu1bChEntrynot-accessiblecurrentNG-RU 1B channels table entry
1.3.6.1.4.1.6626.6000.4.37.3.1.1ColumnspvNgRu1bChIndexnot-accessiblecurrentindex of the channel
1.3.6.1.4.1.6626.6000.4.37.3.1.2ColumnspvNgRu1bRfEnableChread-writecurrentRF enable
1.3.6.1.4.1.6626.6000.4.37.3.1.3ColumnspvNgRu1bAttUlChread-writecurrentAtt UL
1.3.6.1.4.1.6626.6000.4.37.3.1.4ColumnspvNgRu1bAttDlChread-writecurrentAtt DL
1.3.6.1.4.1.6626.6000.4.37.3.1.5ColumnspvNgRu1bPwrDlChread-onlycurrentPower DL
1.3.6.1.4.1.6626.6000.4.38NodespvNgRu2b
1.3.6.1.4.1.6626.6000.4.38.1TablespvNgRu2bTablenot-accessiblecurrent
1.3.6.1.4.1.6626.6000.4.38.1.1RowspvNgRu2bEntrynot-accessiblecurrent
1.3.6.1.4.1.6626.6000.4.38.1.1.1ColumnspvNgRu2bIndexnot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.2ColumnspvNgRu2bTyperead-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.3ColumnspvNgRu2bModelread-onlycurrent
1.3.6.1.4.1.6626.6000.4.38.1.1.4ColumnspvNgRu2bCommercialCoderead-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.5ColumnspvNgRu2bCommercialDescriptionread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.6ColumnspvNgRu2bVersionread-onlycurrentx.y.z.p
1.3.6.1.4.1.6626.6000.4.38.1.1.7ColumnspvNgRu2bSerialNumberread-onlycurrent
1.3.6.1.4.1.6626.6000.4.38.1.1.8ColumnspvNgRu2bTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.38.1.1.9ColumnspvNgRu2bDataTimestampread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.10ColumnspvNgRu2bDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.38.1.1.11ColumnspvNgRu2bDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.38.1.1.12ColumnspvNgRu2bNameread-writecurrent
1.3.6.1.4.1.6626.6000.4.38.1.1.13ColumnspvNgRu2bDescriptionread-writecurrent
1.3.6.1.4.1.6626.6000.4.38.1.1.14ColumnspvNgRu2bTmpRfBoardread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.15ColumnspvNgRu2bTmpCoreread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.16ColumnspvNgRu2bSfpTemperatureread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.17ColumnspvNgRu2bOptPwrTxread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.18ColumnspvNgRu2bOptPwrRxread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.1.1.19ColumnspvNgRu2bRuAddressread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.38.1.1.20ColumnspvNgRu2bFanSpeed1read-onlycurrentFan speed in rpm
1.3.6.1.4.1.6626.6000.4.38.1.1.21ColumnspvNgRu2bFanSpeed2read-onlycurrentFan speed in rpm
1.3.6.1.4.1.6626.6000.4.38.1.1.22ColumnspvNgRu2bFanSpeed3read-onlycurrentFan speed in rpm
1.3.6.1.4.1.6626.6000.4.38.1.1.23ColumnspvNgRu2bFanSpeed4read-onlycurrentFan speed in rpm
1.3.6.1.4.1.6626.6000.4.38.1.1.24ColumnspvNgRu2bResetread-writecurrentreset the board
1.3.6.1.4.1.6626.6000.4.38.2NodespvNgRu2bAlarm
1.3.6.1.4.1.6626.6000.4.38.2.1TablespvNgRu2bAlarmGlobalTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.1.1RowspvNgRu2bAlarmGlobalEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.1.1.1ColumnspvNgRu2bAlarmGlobalCountread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.1.1.2ColumnspvNgRu2bAlarmMaxSeverityread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.1.1.3ColumnspvNgRu2bReachableread-onlycurrentmodule reachable or not.
1.3.6.1.4.1.6626.6000.4.38.2.2TablespvNgRu2bAlarmTablenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.2.1RowspvNgRu2bAlarmEntrynot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.2.1.1ColumnspvNgRu2bAlarmTypenot-accessiblecurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.2.1.2ColumnspvNgRu2bAlarmEnableread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.2.1.3ColumnspvNgRu2bAlarmStateread-onlycurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.2.1.4ColumnspvNgRu2bAlarmSeverityread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.2.1.5ColumnspvNgRu2bAlarmPolarityread-writecurrentDescription
1.3.6.1.4.1.6626.6000.4.38.2.2.1.6ColumnspvNgRu2bAlarmNameread-writecurrentalarm name.
1.3.6.1.4.1.6626.6000.4.38.3TablespvNgRu2bChTablenot-accessiblecurrentNG-RU 2B channels table
1.3.6.1.4.1.6626.6000.4.38.3.1RowspvNgRu2bChEntrynot-accessiblecurrentNG-RU 2B channels table entry
1.3.6.1.4.1.6626.6000.4.38.3.1.1ColumnspvNgRu2bChIndexnot-accessiblecurrentindex of the channel
1.3.6.1.4.1.6626.6000.4.38.3.1.2ColumnspvNgRu2bRfEnableChread-writecurrentRF enable
1.3.6.1.4.1.6626.6000.4.38.3.1.3ColumnspvNgRu2bAttUlChread-writecurrentAtt UL
1.3.6.1.4.1.6626.6000.4.38.3.1.4ColumnspvNgRu2bAttDlChread-writecurrentAtt DL
1.3.6.1.4.1.6626.6000.4.38.3.1.5ColumnspvNgRu2bPwrDlChread-onlycurrentPower DL
1.3.6.1.4.1.6626.6000.4.39NodespvLpPoiMb
1.3.6.1.4.1.6626.6000.4.39.1TablespvLpPoiMbTablenot-accessiblecurrentPOI table
1.3.6.1.4.1.6626.6000.4.39.1.1RowspvLpPoiMbEntrynot-accessiblecurrentPOI table entry
1.3.6.1.4.1.6626.6000.4.39.1.1.1ColumnspvLpPoiMbIndexnot-accessiblecurrentPOI index
1.3.6.1.4.1.6626.6000.4.39.1.1.2ColumnspvLpPoiMbTyperead-onlycurrentPOI type
1.3.6.1.4.1.6626.6000.4.39.1.1.3ColumnspvLpPoiMbModelread-onlycurrentPOI model
1.3.6.1.4.1.6626.6000.4.39.1.1.4ColumnspvLpPoiMbCommercialCoderead-onlycurrentPOI sale code
1.3.6.1.4.1.6626.6000.4.39.1.1.5ColumnspvLpPoiMbCommercialDescriptionread-onlycurrentPOI sale description
1.3.6.1.4.1.6626.6000.4.39.1.1.6ColumnspvLpPoiMbVersionread-onlycurrentPOI version
1.3.6.1.4.1.6626.6000.4.39.1.1.7ColumnspvLpPoiMbSerialNumberread-onlycurrentPOI serial number
1.3.6.1.4.1.6626.6000.4.39.1.1.8ColumnspvLpPoiMbTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.39.1.1.9ColumnspvLpPoiMbDataTimestampread-onlycurrentPOI timestamp date
1.3.6.1.4.1.6626.6000.4.39.1.1.10ColumnspvLpPoiMbDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.39.1.1.11ColumnspvLpPoiMbDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.39.1.1.12ColumnspvLpPoiMbNameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.39.1.1.13ColumnspvLpPoiMbTemperatureread-onlycurrenttemperature in (C)
1.3.6.1.4.1.6626.6000.4.39.1.1.14ColumnspvLpPoiMbCurrentread-writecurrentCurrent (mA)
1.3.6.1.4.1.6626.6000.4.39.1.1.15ColumnspvLpPoiMbPwrAlarmHysteresisread-writecurrentpower hysteresis
1.3.6.1.4.1.6626.6000.4.39.1.1.16ColumnspvLpPoiMbFanSpeedRead1read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.39.1.1.17ColumnspvLpPoiMbFanSpeedRead2read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.39.1.1.18ColumnspvLpPoiMbFanSpeedRead3read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.39.1.1.19ColumnspvLpPoiMbFanSpeedRead4read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.39.1.1.20ColumnspvLpPoiMbRfPathMappingread-writecurrentRF Path Mapping
1.3.6.1.4.1.6626.6000.4.39.1.1.21ColumnspvLpPoiMbAttDigMonitorread-writecurrentAtt. TDD REF OUT (dB)
1.3.6.1.4.1.6626.6000.4.39.2TablespvLpPoiMbBandTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.39.2.1RowspvLpPoiMbBandEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.39.2.1.1ColumnspvLpPoiMbBandIndexnot-accessiblecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.39.2.1.2ColumnspvLpPoiMbBandNameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.39.2.1.3ColumnspvLpPoiMbEnableInUl1read-writecurrentUL enable In
1.3.6.1.4.1.6626.6000.4.39.2.1.4ColumnspvLpPoiMbEnableOutUl1read-writecurrentUL enable Out
1.3.6.1.4.1.6626.6000.4.39.2.1.5ColumnspvLpPoiMbEnableDl1read-writecurrentDL enable
1.3.6.1.4.1.6626.6000.4.39.2.1.6ColumnspvLpPoiMbRmsPwrOutDl1read-onlycurrentRMS Power Out DL (dBm)
1.3.6.1.4.1.6626.6000.4.39.2.1.7ColumnspvLpPoiMbRmsPwrInDl1read-onlycurrentRMS Power In DL (dBm)
1.3.6.1.4.1.6626.6000.4.39.2.1.8ColumnspvLpPoiMbThrMinRmsPwrInDl1read-writecurrentThr RMS Power In Min (dBm)
1.3.6.1.4.1.6626.6000.4.39.2.1.9ColumnspvLpPoiMbThrMaxRmsPwrInDl1read-writecurrentThr RMS Power In Max (dBm)
1.3.6.1.4.1.6626.6000.4.39.2.1.10ColumnspvLpPoiMbAttDigitUl1read-writecurrentDigit attenuation UL (dB)
1.3.6.1.4.1.6626.6000.4.39.2.1.11ColumnspvLpPoiMbAttDigitDl1read-writecurrentDigit attenuation DL (dB)
1.3.6.1.4.1.6626.6000.4.39.2.1.12ColumnspvLpPoiMbAttMeccDl1read-writecurrentMech attenuation (dB)
1.3.6.1.4.1.6626.6000.4.39.2.1.13ColumnspvLpPoiMbProtection1read-onlycurrentProtection (dB)
1.3.6.1.4.1.6626.6000.4.39.2.1.14ColumnspvLpPoiMbEnableInUl2read-writecurrentUL enable In
1.3.6.1.4.1.6626.6000.4.39.2.1.15ColumnspvLpPoiMbEnableOutUl2read-writecurrentUL enable Out
1.3.6.1.4.1.6626.6000.4.39.2.1.16ColumnspvLpPoiMbEnableDl2read-writecurrentDL enable
1.3.6.1.4.1.6626.6000.4.39.2.1.17ColumnspvLpPoiMbRmsPwrOutDl2read-onlycurrentRMS Power Out DL (dBm)
1.3.6.1.4.1.6626.6000.4.39.2.1.18ColumnspvLpPoiMbRmsPwrInDl2read-onlycurrentRMS Power In DL (dBm)
1.3.6.1.4.1.6626.6000.4.39.2.1.19ColumnspvLpPoiMbThrMinRmsPwrInDl2read-writecurrentThr RMS Power In Min (dBm)
1.3.6.1.4.1.6626.6000.4.39.2.1.20ColumnspvLpPoiMbThrMaxRmsPwrInDl2read-writecurrentThr RMS Power In Max (dBm)
1.3.6.1.4.1.6626.6000.4.39.2.1.21ColumnspvLpPoiMbAttDigitUl2read-writecurrentDigit attenuation UL (dB)
1.3.6.1.4.1.6626.6000.4.39.2.1.22ColumnspvLpPoiMbAttDigitDl2read-writecurrentDigit attenuation DL (dB)
1.3.6.1.4.1.6626.6000.4.39.2.1.23ColumnspvLpPoiMbAttMeccDl2read-writecurrentMech attenuation (dB)
1.3.6.1.4.1.6626.6000.4.39.2.1.24ColumnspvLpPoiMbProtection2read-onlycurrentProtection (dB)
1.3.6.1.4.1.6626.6000.4.39.2.1.25ColumnspvLpPoiMbPwrLimitModeread-writecurrentPower Limiter Mode
1.3.6.1.4.1.6626.6000.4.39.3NodespvLpPoiMbAlarm
1.3.6.1.4.1.6626.6000.4.39.3.1TablespvLpPoiMbAlarmGlobalTablenot-accessiblecurrentalarms global table
1.3.6.1.4.1.6626.6000.4.39.3.1.1RowspvLpPoiMbAlarmGlobalEntrynot-accessiblecurrentalarms global table entry
1.3.6.1.4.1.6626.6000.4.39.3.1.1.1ColumnspvLpPoiMbAlarmGlobalCountread-onlycurrentalarms global count
1.3.6.1.4.1.6626.6000.4.39.3.1.1.2ColumnspvLpPoiMbAlarmMaxSeverityread-onlycurrentalarms max severity
1.3.6.1.4.1.6626.6000.4.39.3.1.1.3ColumnspvLpPoiMbReachableread-onlycurrentreachable
1.3.6.1.4.1.6626.6000.4.39.3.2TablespvLpPoiMbAlarmTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.39.3.2.1RowspvLpPoiMbAlarmEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.39.3.2.1.1ColumnspvLpPoiMbAlarmTypenot-accessiblecurrentalarm type
1.3.6.1.4.1.6626.6000.4.39.3.2.1.2ColumnspvLpPoiMbAlarmEnableread-writecurrentalarm enable
1.3.6.1.4.1.6626.6000.4.39.3.2.1.3ColumnspvLpPoiMbAlarmStateread-onlycurrentalarm state
1.3.6.1.4.1.6626.6000.4.39.3.2.1.4ColumnspvLpPoiMbAlarmSeverityread-onlycurrentalarm severity
1.3.6.1.4.1.6626.6000.4.39.3.2.1.5ColumnspvLpPoiMbAlarmPolarityread-onlycurrentalarm polarity
1.3.6.1.4.1.6626.6000.4.39.3.2.1.6ColumnspvLpPoiMbAlarmNameread-onlycurrentalarm name
1.3.6.1.4.1.6626.6000.4.40NodespvPoiOran
1.3.6.1.4.1.6626.6000.4.40.1TablespvPoiOranTablenot-accessiblecurrentPOI ORAN table
1.3.6.1.4.1.6626.6000.4.40.1.1RowspvPoiOranEntrynot-accessiblecurrentPOI table entry
1.3.6.1.4.1.6626.6000.4.40.1.1.1ColumnspvPoiOranIndexnot-accessiblecurrentPOI index
1.3.6.1.4.1.6626.6000.4.40.1.1.2ColumnspvPoiOranTyperead-onlycurrentPOI type
1.3.6.1.4.1.6626.6000.4.40.1.1.3ColumnspvPoiOranModelread-onlycurrentPOI model
1.3.6.1.4.1.6626.6000.4.40.1.1.4ColumnspvPoiOranCommercialCoderead-onlycurrentPOI sale code
1.3.6.1.4.1.6626.6000.4.40.1.1.5ColumnspvPoiOranCommercialDescriptionread-onlycurrentPOI sale description
1.3.6.1.4.1.6626.6000.4.40.1.1.6ColumnspvPoiOranVersionread-onlycurrentPOI version
1.3.6.1.4.1.6626.6000.4.40.1.1.7ColumnspvPoiOranSerialNumberread-onlycurrentPOI serial number
1.3.6.1.4.1.6626.6000.4.40.1.1.8ColumnspvPoiOranTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.40.1.1.9ColumnspvPoiOranDataTimestampread-onlycurrentPOI timestamp date
1.3.6.1.4.1.6626.6000.4.40.1.1.10ColumnspvPoiOranDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.40.1.1.11ColumnspvPoiOranDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.40.1.1.12ColumnspvPoiOranNameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.40.1.1.13ColumnspvPoiOranTemperatureread-onlycurrenttemperature in (C)
1.3.6.1.4.1.6626.6000.4.40.1.1.14ColumnspvPoiOranTypeDigitread-onlycurrentHex string for digit type
1.3.6.1.4.1.6626.6000.4.40.1.1.15ColumnspvPoiOranVersionDigitread-onlycurrentHex string for digit version
1.3.6.1.4.1.6626.6000.4.40.2TablespvPoiOranChannelTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.40.2.1RowspvPoiOranChannelEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.40.2.1.1ColumnspvPoiOranChannelIndexnot-accessiblecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.40.2.1.2ColumnspvPoiOranChannelNameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.40.2.1.3ColumnspvPoiOranEnableUlread-writecurrentUL enable
1.3.6.1.4.1.6626.6000.4.40.2.1.4ColumnspvPoiOranEnableDlread-writecurrentDL enable
1.3.6.1.4.1.6626.6000.4.40.2.1.5ColumnspvPoiOranRmsPwrDlread-onlycurrentpeak power (dBm)
1.3.6.1.4.1.6626.6000.4.40.2.1.6ColumnspvPoiOranAttDigitUlread-writecurrentDigit attenuation UL (dB)
1.3.6.1.4.1.6626.6000.4.40.2.1.7ColumnspvPoiOranAttDigitDlread-writecurrentDigit attenuation DL (dB)
1.3.6.1.4.1.6626.6000.4.40.3NodespvPoiOranAlarm
1.3.6.1.4.1.6626.6000.4.40.3.1TablespvPoiOranAlarmGlobalTablenot-accessiblecurrentalarms global table
1.3.6.1.4.1.6626.6000.4.40.3.1.1RowspvPoiOranAlarmGlobalEntrynot-accessiblecurrentalarms global table entry
1.3.6.1.4.1.6626.6000.4.40.3.1.1.1ColumnspvPoiOranAlarmGlobalCountread-onlycurrentalarms global count
1.3.6.1.4.1.6626.6000.4.40.3.1.1.2ColumnspvPoiOranAlarmMaxSeverityread-onlycurrentalarms max severity
1.3.6.1.4.1.6626.6000.4.40.3.1.1.3ColumnspvPoiOranReachableread-onlycurrentreachable
1.3.6.1.4.1.6626.6000.4.40.3.2TablespvPoiOranAlarmTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.40.3.2.1RowspvPoiOranAlarmEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.40.3.2.1.1ColumnspvPoiOranAlarmTypenot-accessiblecurrentalarm type
1.3.6.1.4.1.6626.6000.4.40.3.2.1.2ColumnspvPoiOranAlarmEnableread-writecurrentalarm enable
1.3.6.1.4.1.6626.6000.4.40.3.2.1.3ColumnspvPoiOranAlarmStateread-onlycurrentalarm state
1.3.6.1.4.1.6626.6000.4.40.3.2.1.4ColumnspvPoiOranAlarmSeverityread-onlycurrentalarm severity
1.3.6.1.4.1.6626.6000.4.40.3.2.1.5ColumnspvPoiOranAlarmPolarityread-onlycurrentalarm polarity
1.3.6.1.4.1.6626.6000.4.40.3.2.1.6ColumnspvPoiOranAlarmNameread-onlycurrentalarm name
1.3.6.1.4.1.6626.6000.4.41NodespvHPLowPIMPoi
1.3.6.1.4.1.6626.6000.4.41.1TablespvHPLowPIMPoiTablenot-accessiblecurrentPOI table
1.3.6.1.4.1.6626.6000.4.41.1.1RowspvHPLowPIMPoiEntrynot-accessiblecurrentPOI table entry
1.3.6.1.4.1.6626.6000.4.41.1.1.1ColumnspvHPLowPIMPoiIndexnot-accessiblecurrentPOI index
1.3.6.1.4.1.6626.6000.4.41.1.1.2ColumnspvHPLowPIMPoiTyperead-onlycurrentPOI type
1.3.6.1.4.1.6626.6000.4.41.1.1.3ColumnspvHPLowPIMPoiModelread-onlycurrentPOI model
1.3.6.1.4.1.6626.6000.4.41.1.1.4ColumnspvHPLowPIMPoiCommercialCoderead-onlycurrentPOI sale code
1.3.6.1.4.1.6626.6000.4.41.1.1.5ColumnspvHPLowPIMPoiCommercialDescriptionread-onlycurrentPOI sale description
1.3.6.1.4.1.6626.6000.4.41.1.1.6ColumnspvHPLowPIMPoiVersionread-onlycurrentPOI version
1.3.6.1.4.1.6626.6000.4.41.1.1.7ColumnspvHPLowPIMPoiSerialNumberread-onlycurrentPOI serial number
1.3.6.1.4.1.6626.6000.4.41.1.1.8ColumnspvHPLowPIMPoiTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.41.1.1.9ColumnspvHPLowPIMPoiDataTimestampread-onlycurrentPOI timestamp date
1.3.6.1.4.1.6626.6000.4.41.1.1.10ColumnspvHPLowPIMPoiDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.41.1.1.11ColumnspvHPLowPIMPoiDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.41.1.1.12ColumnspvHPLowPIMPoiNameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.41.1.1.13ColumnspvHPLowPIMPoiTemperatureread-onlycurrenttemperature in (C)
1.3.6.1.4.1.6626.6000.4.41.1.1.14ColumnspvHPLowPIMPoiCurrentread-writecurrentCurrent (mA)
1.3.6.1.4.1.6626.6000.4.41.1.1.15ColumnspvHPLowPIMPoiFanSpeedRead1read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.41.1.1.16ColumnspvHPLowPIMPoiFanSpeedRead2read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.41.1.1.17ColumnspvHPLowPIMPoiFanSpeedRead3read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.41.1.1.18ColumnspvHPLowPIMPoiFanSpeedRead4read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.41.1.1.19ColumnspvHPLowPIMPoiFanSpeedRead5read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.41.1.1.20ColumnspvHPLowPIMPoiFanSpeedRead6read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.41.1.1.21ColumnspvHPLowPIMPoiFanSpeedRead7read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.41.1.1.22ColumnspvHPLowPIMPoiFanSpeedRead8read-writecurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.41.2TablespvHPLowPIMPoiChTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.41.2.1RowspvHPLowPIMPoiChEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.41.2.1.1ColumnspvHPLowPIMPoiChIndexnot-accessiblecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.41.2.1.2ColumnspvHPLowPIMPoiChNameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.41.2.1.3ColumnspvHPLowPIMPoiChTemperatureread-onlycurrentRMS Power Out DL (dBm)
1.3.6.1.4.1.6626.6000.4.41.3NodespvHPLowPIMPoiAlarm
1.3.6.1.4.1.6626.6000.4.41.3.1TablespvHPLowPIMPoiAlarmGlobalTablenot-accessiblecurrentalarms global table
1.3.6.1.4.1.6626.6000.4.41.3.1.1RowspvHPLowPIMPoiAlarmGlobalEntrynot-accessiblecurrentalarms global table entry
1.3.6.1.4.1.6626.6000.4.41.3.1.1.1ColumnspvHPLowPIMPoiAlarmGlobalCountread-onlycurrentalarms global count
1.3.6.1.4.1.6626.6000.4.41.3.1.1.2ColumnspvHPLowPIMPoiAlarmMaxSeverityread-onlycurrentalarms max severity
1.3.6.1.4.1.6626.6000.4.41.3.1.1.3ColumnspvHPLowPIMPoiReachableread-onlycurrentreachable
1.3.6.1.4.1.6626.6000.4.41.3.2TablespvHPLowPIMPoiAlarmTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.41.3.2.1RowspvHPLowPIMPoiAlarmEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.41.3.2.1.1ColumnspvHPLowPIMPoiAlarmTypenot-accessiblecurrentalarm type
1.3.6.1.4.1.6626.6000.4.41.3.2.1.2ColumnspvHPLowPIMPoiAlarmEnableread-writecurrentalarm enable
1.3.6.1.4.1.6626.6000.4.41.3.2.1.3ColumnspvHPLowPIMPoiAlarmStateread-onlycurrentalarm state
1.3.6.1.4.1.6626.6000.4.41.3.2.1.4ColumnspvHPLowPIMPoiAlarmSeverityread-onlycurrentalarm severity
1.3.6.1.4.1.6626.6000.4.41.3.2.1.5ColumnspvHPLowPIMPoiAlarmPolarityread-onlycurrentalarm polarity
1.3.6.1.4.1.6626.6000.4.41.3.2.1.6ColumnspvHPLowPIMPoiAlarmNameread-onlycurrentalarm name
1.3.6.1.4.1.6626.6000.4.42NodespvPoiOranV2
1.3.6.1.4.1.6626.6000.4.42.1TablespvPoiOranV2Tablenot-accessiblecurrentPOI ORAN V2 table
1.3.6.1.4.1.6626.6000.4.42.1.1RowspvPoiOranV2Entrynot-accessiblecurrentPOI ORAN V2 table entry
1.3.6.1.4.1.6626.6000.4.42.1.1.1ColumnspvPoiOranV2Indexnot-accessiblecurrentPOI ORAN V2index
1.3.6.1.4.1.6626.6000.4.42.1.1.2ColumnspvPoiOranV2Typeread-onlycurrentPOI ORAN V2type
1.3.6.1.4.1.6626.6000.4.42.1.1.3ColumnspvPoiOranV2Modelread-onlycurrentPOI ORAN V2model
1.3.6.1.4.1.6626.6000.4.42.1.1.4ColumnspvPoiOranV2CommercialCoderead-onlycurrentPOI ORAN V2sale code
1.3.6.1.4.1.6626.6000.4.42.1.1.5ColumnspvPoiOranV2CommercialDescriptionread-onlycurrentPOI ORAN V2sale description
1.3.6.1.4.1.6626.6000.4.42.1.1.6ColumnspvPoiOranV2Versionread-onlycurrentPOI ORAN V2version
1.3.6.1.4.1.6626.6000.4.42.1.1.7ColumnspvPoiOranV2SerialNumberread-onlycurrentPOI ORAN V2serial number
1.3.6.1.4.1.6626.6000.4.42.1.1.8ColumnspvPoiOranV2TypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.42.1.1.9ColumnspvPoiOranV2DataTimestampread-onlycurrentPOI ORAN V2timestamp date
1.3.6.1.4.1.6626.6000.4.42.1.1.10ColumnspvPoiOranV2DataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.42.1.1.11ColumnspvPoiOranV2DataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.42.1.1.12ColumnspvPoiOranV2Nameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.42.1.1.13ColumnspvPoiOranV2Temperatureread-onlycurrenttemperature in (C)
1.3.6.1.4.1.6626.6000.4.42.1.1.14ColumnspvPoiOranV2TypeDigitread-onlycurrentHex string for digit type
1.3.6.1.4.1.6626.6000.4.42.1.1.15ColumnspvPoiOranV2VersionDigitread-onlycurrentHex string for digit version
1.3.6.1.4.1.6626.6000.4.42.1.1.16ColumnspvPoiOranV2SectorPortControlread-writecurrentSector Port Control
1.3.6.1.4.1.6626.6000.4.42.2TablespvPoiOranV2ChannelTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.42.2.1RowspvPoiOranV2ChannelEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.42.2.1.1ColumnspvPoiOranV2ChannelIndexnot-accessiblecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.42.2.1.2ColumnspvPoiOranV2ChannelNameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.42.2.1.3ColumnspvPoiOranV2EnableUlread-writecurrentUL enable
1.3.6.1.4.1.6626.6000.4.42.2.1.4ColumnspvPoiOranV2EnableDlread-writecurrentDL enable
1.3.6.1.4.1.6626.6000.4.42.2.1.5ColumnspvPoiOranV2RmsPwrDlread-onlycurrentpeak power (dBm)
1.3.6.1.4.1.6626.6000.4.42.2.1.6ColumnspvPoiOranV2AttDigitUlread-writecurrentDigit attenuation UL (dB)
1.3.6.1.4.1.6626.6000.4.42.2.1.7ColumnspvPoiOranV2AttDigitDlread-writecurrentDigit attenuation DL (dB)
1.3.6.1.4.1.6626.6000.4.42.3NodespvPoiOranV2Alarm
1.3.6.1.4.1.6626.6000.4.42.3.1TablespvPoiOranV2AlarmGlobalTablenot-accessiblecurrentalarms global table
1.3.6.1.4.1.6626.6000.4.42.3.1.1RowspvPoiOranV2AlarmGlobalEntrynot-accessiblecurrentalarms global table entry
1.3.6.1.4.1.6626.6000.4.42.3.1.1.1ColumnspvPoiOranV2AlarmGlobalCountread-onlycurrentalarms global count
1.3.6.1.4.1.6626.6000.4.42.3.1.1.2ColumnspvPoiOranV2AlarmMaxSeverityread-onlycurrentalarms max severity
1.3.6.1.4.1.6626.6000.4.42.3.1.1.3ColumnspvPoiOranV2Reachableread-onlycurrentreachable
1.3.6.1.4.1.6626.6000.4.42.3.2TablespvPoiOranV2AlarmTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.42.3.2.1RowspvPoiOranV2AlarmEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.42.3.2.1.1ColumnspvPoiOranV2AlarmTypenot-accessiblecurrentalarm type
1.3.6.1.4.1.6626.6000.4.42.3.2.1.2ColumnspvPoiOranV2AlarmEnableread-writecurrentalarm enable
1.3.6.1.4.1.6626.6000.4.42.3.2.1.3ColumnspvPoiOranV2AlarmStateread-onlycurrentalarm state
1.3.6.1.4.1.6626.6000.4.42.3.2.1.4ColumnspvPoiOranV2AlarmSeverityread-onlycurrentalarm severity
1.3.6.1.4.1.6626.6000.4.42.3.2.1.5ColumnspvPoiOranV2AlarmPolarityread-onlycurrentalarm polarity
1.3.6.1.4.1.6626.6000.4.42.3.2.1.6ColumnspvPoiOranV2AlarmNameread-onlycurrentalarm name
1.3.6.1.4.1.6626.6000.4.42.4TablespvPoiOranV2SfpTablenot-accessiblecurrentSFP table
1.3.6.1.4.1.6626.6000.4.42.4.1RowspvPoiOranV2SfpEntrynot-accessiblecurrentPOI ORAN V2 SFP entry
1.3.6.1.4.1.6626.6000.4.42.4.1.1ColumnspvPoiOranV2SfpTemperatureread-onlycurrentSFP Temperature (C)
1.3.6.1.4.1.6626.6000.4.42.4.1.2ColumnspvPoiOranV2SfpPowerTxread-onlycurrentSFP Power TX (dBm)
1.3.6.1.4.1.6626.6000.4.42.4.1.3ColumnspvPoiOranV2SfpPowerRxread-onlycurrentSFP Power RX (dBm)
1.3.6.1.4.1.6626.6000.4.42.4.1.4ColumnspvPoiOranV2SfpVccread-onlycurrentSFP VCC (V)
1.3.6.1.4.1.6626.6000.4.42.4.1.5ColumnspvPoiOranV2SfpBiasCurrTxread-onlycurrentSFP Bias Current TX (mA)
1.3.6.1.4.1.6626.6000.4.42.4.1.6ColumnspvPoiOranV2SfpNominalBitrateread-onlycurrentSFP Nominal bitrate (Gbps)
1.3.6.1.4.1.6626.6000.4.42.4.1.7ColumnspvPoiOranV2SfpVendorNameread-onlycurrentSFP Vendor name
1.3.6.1.4.1.6626.6000.4.42.4.1.8ColumnspvPoiOranV2SfpVendorPnread-onlycurrentSFP Vendor Part Number
1.3.6.1.4.1.6626.6000.4.42.4.1.9ColumnspvPoiOranV2SfpVendorSnread-onlycurrentSFP Vendor Serial Number
1.3.6.1.4.1.6626.6000.4.42.4.1.10ColumnspvPoiOranV2SfpBitrateread-writecurrentSFP bitrate
1.3.6.1.4.1.6626.6000.4.42.4.1.11ColumnspvPoiOranV2SfpFecEnableread-writecurrentSFP RS-FEC enable
1.3.6.1.4.1.6626.6000.4.42.5TablespvPoiOranV2CarrierTablenot-accessiblecurrentCarrier table
1.3.6.1.4.1.6626.6000.4.42.5.1RowspvPoiOranV2CarrierEntrynot-accessiblecurrentPOI ORAN V2 Carrier entry
1.3.6.1.4.1.6626.6000.4.42.5.1.1ColumnspvPoiOranV2CarrierIndexnot-accessiblecurrentCarrier index
1.3.6.1.4.1.6626.6000.4.42.5.1.2ColumnspvPoiOranV2CarrierCenterFreqDlread-onlycurrentCarrier Center Freq DL (Mhz)
1.3.6.1.4.1.6626.6000.4.42.5.1.3ColumnspvPoiOranV2CarrierBandwidthDlread-onlycurrentCarrier Bandwidth DL (Mhz)
1.3.6.1.4.1.6626.6000.4.42.5.1.4ColumnspvPoiOranV2CarrierChMappedBitmaskDlread-onlycurrentCarrier Ch mapped bitmask DL
1.3.6.1.4.1.6626.6000.4.42.5.1.5ColumnspvPoiOranV2CarrierCenterFreqUlread-onlycurrentCarrier Center Freq UL (Mhz)
1.3.6.1.4.1.6626.6000.4.42.5.1.6ColumnspvPoiOranV2CarrierBandwidthUlread-onlycurrentCarrier Bandwidth UL (Mhz)
1.3.6.1.4.1.6626.6000.4.42.5.1.7ColumnspvPoiOranV2CarrierChMappedBitmaskUlread-onlycurrentCarrier Ch mapped bitmask UL
1.3.6.1.4.1.6626.6000.4.43NodespvLpPoiMbWt
1.3.6.1.4.1.6626.6000.4.43.1TablespvLpPoiMbWtTablenot-accessiblecurrentPOI table
1.3.6.1.4.1.6626.6000.4.43.1.1RowspvLpPoiMbWtEntrynot-accessiblecurrentPOI table entry
1.3.6.1.4.1.6626.6000.4.43.1.1.1ColumnspvLpPoiMbWtIndexnot-accessiblecurrentPOI index
1.3.6.1.4.1.6626.6000.4.43.1.1.2ColumnspvLpPoiMbWtTyperead-onlycurrentPOI type
1.3.6.1.4.1.6626.6000.4.43.1.1.3ColumnspvLpPoiMbWtModelread-onlycurrentPOI model
1.3.6.1.4.1.6626.6000.4.43.1.1.4ColumnspvLpPoiMbWtCommercialCoderead-onlycurrentPOI sale code
1.3.6.1.4.1.6626.6000.4.43.1.1.5ColumnspvLpPoiMbWtCommercialDescriptionread-onlycurrentPOI sale description
1.3.6.1.4.1.6626.6000.4.43.1.1.6ColumnspvLpPoiMbWtVersionread-onlycurrentPOI version
1.3.6.1.4.1.6626.6000.4.43.1.1.7ColumnspvLpPoiMbWtSerialNumberread-onlycurrentPOI serial number
1.3.6.1.4.1.6626.6000.4.43.1.1.8ColumnspvLpPoiMbWtTypeNameread-onlycurrentmodule name
1.3.6.1.4.1.6626.6000.4.43.1.1.9ColumnspvLpPoiMbWtDataTimestampread-onlycurrentPOI timestamp date
1.3.6.1.4.1.6626.6000.4.43.1.1.10ColumnspvLpPoiMbWtDataSourceread-writecurrentData source
1.3.6.1.4.1.6626.6000.4.43.1.1.11ColumnspvLpPoiMbWtDataRestoreread-writecurrentData restore
1.3.6.1.4.1.6626.6000.4.43.1.1.12ColumnspvLpPoiMbWtNameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.43.1.1.13ColumnspvLpPoiMbWtTemperatureread-onlycurrenttemperature in (C)
1.3.6.1.4.1.6626.6000.4.43.1.1.14ColumnspvLpPoiMbWtCurrentread-onlycurrentCurrent (mA)
1.3.6.1.4.1.6626.6000.4.43.1.1.15ColumnspvLpPoiMbWtPwrAlarmHysteresisread-writecurrentpower hysteresis
1.3.6.1.4.1.6626.6000.4.43.1.1.16ColumnspvLpPoiMbWtFanSpeedRead1read-onlycurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.43.1.1.17ColumnspvLpPoiMbWtFanSpeedRead2read-onlycurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.43.1.1.18ColumnspvLpPoiMbWtFanSpeedRead3read-onlycurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.43.1.1.19ColumnspvLpPoiMbWtFanSpeedRead4read-onlycurrentFan Speed (rpm)
1.3.6.1.4.1.6626.6000.4.43.1.1.20ColumnspvLpPoiMbWtTsyncActiveSelectorread-writecurrentTsync active
1.3.6.1.4.1.6626.6000.4.43.1.1.21ColumnspvLpPoiMbWtTsyncSwitchBackread-writecurrentTsync switchback
1.3.6.1.4.1.6626.6000.4.43.2TablespvLpPoiMbWtBandTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.43.2.1RowspvLpPoiMbWtBandEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.43.2.1.1ColumnspvLpPoiMbWtBandIndexnot-accessiblecurrentBand index
1.3.6.1.4.1.6626.6000.4.43.2.1.2ColumnspvLpPoiMbWtBandNameread-writecurrentName, max 30 char
1.3.6.1.4.1.6626.6000.4.43.2.1.3ColumnspvLpPoiMbWtEnableInUl1read-writecurrentUL enable In
1.3.6.1.4.1.6626.6000.4.43.2.1.4ColumnspvLpPoiMbWtEnableOutUl1read-writecurrentUL enable Out
1.3.6.1.4.1.6626.6000.4.43.2.1.5ColumnspvLpPoiMbWtEnableDl1read-writecurrentDL enable
1.3.6.1.4.1.6626.6000.4.43.2.1.6ColumnspvLpPoiMbWtRmsPwrOutDl1read-onlycurrentRMS Power Out DL (dBm)
1.3.6.1.4.1.6626.6000.4.43.2.1.7ColumnspvLpPoiMbWtRmsPwrInDl1read-onlycurrentRMS Power In DL (dBm)
1.3.6.1.4.1.6626.6000.4.43.2.1.8ColumnspvLpPoiMbWtThrMinRmsPwrInDl1read-writecurrentThr RMS Power In Min (dBm)
1.3.6.1.4.1.6626.6000.4.43.2.1.9ColumnspvLpPoiMbWtThrMaxRmsPwrInDl1read-writecurrentThr RMS Power In Max (dBm)
1.3.6.1.4.1.6626.6000.4.43.2.1.10ColumnspvLpPoiMbWtAttDigitUl1read-writecurrentDigit attenuation UL (dB)
1.3.6.1.4.1.6626.6000.4.43.2.1.11ColumnspvLpPoiMbWtAttDigitDl1read-writecurrentDigit attenuation DL (dB)
1.3.6.1.4.1.6626.6000.4.43.2.1.12ColumnspvLpPoiMbWtAttMeccDl1read-writecurrentMech attenuation (dB)
1.3.6.1.4.1.6626.6000.4.43.2.1.13ColumnspvLpPoiMbWtProtection1read-onlycurrentProtection (dB)
1.3.6.1.4.1.6626.6000.4.43.2.1.14ColumnspvLpPoiMbWtEnableInUl2read-writecurrentUL enable In
1.3.6.1.4.1.6626.6000.4.43.2.1.15ColumnspvLpPoiMbWtEnableOutUl2read-writecurrentUL enable Out
1.3.6.1.4.1.6626.6000.4.43.2.1.16ColumnspvLpPoiMbWtEnableDl2read-writecurrentDL enable
1.3.6.1.4.1.6626.6000.4.43.2.1.17ColumnspvLpPoiMbWtRmsPwrOutDl2read-onlycurrentRMS Power Out DL (dBm)
1.3.6.1.4.1.6626.6000.4.43.2.1.18ColumnspvLpPoiMbWtRmsPwrInDl2read-onlycurrentRMS Power In DL (dBm)
1.3.6.1.4.1.6626.6000.4.43.2.1.19ColumnspvLpPoiMbWtThrMinRmsPwrInDl2read-writecurrentThr RMS Power In Min (dBm)
1.3.6.1.4.1.6626.6000.4.43.2.1.20ColumnspvLpPoiMbWtThrMaxRmsPwrInDl2read-writecurrentThr RMS Power In Max (dBm)
1.3.6.1.4.1.6626.6000.4.43.2.1.21ColumnspvLpPoiMbWtAttDigitUl2read-writecurrentDigit attenuation UL (dB)
1.3.6.1.4.1.6626.6000.4.43.2.1.22ColumnspvLpPoiMbWtAttDigitDl2read-writecurrentDigit attenuation DL (dB)
1.3.6.1.4.1.6626.6000.4.43.2.1.23ColumnspvLpPoiMbWtAttMeccDl2read-writecurrentMech attenuation (dB)
1.3.6.1.4.1.6626.6000.4.43.2.1.24ColumnspvLpPoiMbWtProtection2read-onlycurrentProtection (dB)
1.3.6.1.4.1.6626.6000.4.43.2.1.25ColumnspvLpPoiMbWtPwrLimitModeread-writecurrentPower Limiter Mode
1.3.6.1.4.1.6626.6000.4.43.2.1.26ColumnspvLpPoiMbWtAttDigMonitorread-onlycurrentAtt. TDD REF OUT (dB)
1.3.6.1.4.1.6626.6000.4.43.2.1.27ColumnspvLpPoiMbWtTddHoldoverMinread-writecurrentHoldover time (minutes)
1.3.6.1.4.1.6626.6000.4.43.2.1.28ColumnspvLpPoiMbWtTddSsbFilterWidthread-writecurrentSSB filter width
1.3.6.1.4.1.6626.6000.4.43.2.1.29ColumnspvLpPoiMbWtTddSearchStartLevelread-writecurrentSearch Start Level (dBm)
1.3.6.1.4.1.6626.6000.4.43.2.1.30ColumnspvLpPoiMbWtTddPattern2Enread-writecurrentPattern 2 enabled
1.3.6.1.4.1.6626.6000.4.43.2.1.31ColumnspvLpPoiMbWtTddSsPositionread-writecurrentSSB position
1.3.6.1.4.1.6626.6000.4.43.2.1.32ColumnspvLpPoiMbWtTddPeriodPattern1read-writecurrentDL/UL Pattern 1 duration (ms)
1.3.6.1.4.1.6626.6000.4.43.2.1.33ColumnspvLpPoiMbWtTddPeriodPattern2read-writecurrentDL/UL Pattern 2 duration (ms)
1.3.6.1.4.1.6626.6000.4.43.2.1.34ColumnspvLpPoiMbWtTddNbrDlSlots1read-writecurrentNbr of DL slots Pattern 1
1.3.6.1.4.1.6626.6000.4.43.2.1.35ColumnspvLpPoiMbWtTddNbrDlSymbols1read-writecurrentNbr of DL symbols Pattern 1
1.3.6.1.4.1.6626.6000.4.43.2.1.36ColumnspvLpPoiMbWtTddNbrDlSlots2read-writecurrentNbr of DL slots Pattern 2
1.3.6.1.4.1.6626.6000.4.43.2.1.37ColumnspvLpPoiMbWtTddNbrDlSymbols2read-writecurrentNbr of DL symbols Pattern 2
1.3.6.1.4.1.6626.6000.4.43.2.1.38ColumnspvLpPoiMbWtTddConfigScsIndexread-writecurrentSubcarrier spacing (kHz)
1.3.6.1.4.1.6626.6000.4.43.2.1.39ColumnspvLpPoiMbWtTddBandFilterread-writecurrentBand filter
1.3.6.1.4.1.6626.6000.4.43.2.1.40ColumnspvLpPoiMbWtEnableDrvDl1read-writecurrentDriver DL1 enable
1.3.6.1.4.1.6626.6000.4.43.2.1.41ColumnspvLpPoiMbWtEnableDrvDl2read-writecurrentDriver DL2 enable
1.3.6.1.4.1.6626.6000.4.43.3NodespvLpPoiMbWtAlarm
1.3.6.1.4.1.6626.6000.4.43.3.1TablespvLpPoiMbWtAlarmGlobalTablenot-accessiblecurrentalarms global table
1.3.6.1.4.1.6626.6000.4.43.3.1.1RowspvLpPoiMbWtAlarmGlobalEntrynot-accessiblecurrentalarms global table entry
1.3.6.1.4.1.6626.6000.4.43.3.1.1.1ColumnspvLpPoiMbWtAlarmGlobalCountread-onlycurrentalarms global count
1.3.6.1.4.1.6626.6000.4.43.3.1.1.2ColumnspvLpPoiMbWtAlarmMaxSeverityread-onlycurrentalarms max severity
1.3.6.1.4.1.6626.6000.4.43.3.1.1.3ColumnspvLpPoiMbWtReachableread-onlycurrentreachable
1.3.6.1.4.1.6626.6000.4.43.3.2TablespvLpPoiMbWtAlarmTablenot-accessiblecurrentalarms table
1.3.6.1.4.1.6626.6000.4.43.3.2.1RowspvLpPoiMbWtAlarmEntrynot-accessiblecurrentalarms table entry
1.3.6.1.4.1.6626.6000.4.43.3.2.1.1ColumnspvLpPoiMbWtAlarmTypenot-accessiblecurrentalarm type
1.3.6.1.4.1.6626.6000.4.43.3.2.1.2ColumnspvLpPoiMbWtAlarmEnableread-writecurrentalarm enable
1.3.6.1.4.1.6626.6000.4.43.3.2.1.3ColumnspvLpPoiMbWtAlarmStateread-onlycurrentalarm state
1.3.6.1.4.1.6626.6000.4.43.3.2.1.4ColumnspvLpPoiMbWtAlarmSeverityread-onlycurrentalarm severity
1.3.6.1.4.1.6626.6000.4.43.3.2.1.5ColumnspvLpPoiMbWtAlarmPolarityread-onlycurrentalarm polarity
1.3.6.1.4.1.6626.6000.4.43.3.2.1.6ColumnspvLpPoiMbWtAlarmNameread-onlycurrentalarm name
1.3.6.1.4.1.6626.6000.4.43.4TablespvLpPoiMbWtTsyncTablenot-accessiblecurrentTsync table
1.3.6.1.4.1.6626.6000.4.43.4.1RowspvLpPoiMbWtTsyncEntrynot-accessiblecurrentTsync table entry
1.3.6.1.4.1.6626.6000.4.43.4.1.1ColumnspvLpPoiMbWtTsyncIndexnot-accessiblecurrentTsync index
1.3.6.1.4.1.6626.6000.4.43.4.1.2ColumnspvLpPoiMbWtTsyncRfConfread-writecurrentTsync configuration
1.3.6.1.4.1.6626.6000.4.43.4.1.3ColumnspvLpPoiMbWtTsyncHardResetread-writecurrentTDD Device Reset
1.3.6.1.4.1.6626.6000.4.43.4.1.4ColumnspvLpPoiMbWtTsyncVersionMajorread-onlycurrentTDD Version Major
1.3.6.1.4.1.6626.6000.4.43.4.1.5ColumnspvLpPoiMbWtTsyncVersionMinorread-onlycurrentTDD Version Minor
1.3.6.1.4.1.6626.6000.4.100NodespvNotification
1.3.6.1.4.1.6626.6000.4.100.1NotificationspvAlarmNotificationcurrentAlarm notification
1.3.6.1.4.1.6626.6000.4.100.2NotificationspvHeartbeatNotificationcurrentHeartbeat trap notification
1.3.6.1.4.1.6626.6000.4.101NodespvConformance
1.3.6.1.4.1.6626.6000.4.101.1NodespvGroups
1.3.6.1.4.1.6626.6000.4.101.1.1GroupspvObjectGroupcurrentAll the variables in the MIB.
1.3.6.1.4.1.6626.6000.4.101.1.2GroupspvNotificationGroupcurrentDescription
1.3.6.1.4.1.6626.6000.4.101.2NodespvCompliance
1.3.6.1.4.1.6626.6000.4.101.2.1CompliancebasicSPVCompliancecurrentDescription
Type Definitions
NameSyntaxStatusDescription
ModuleModelOCTET STRING (SIZE(13))currentModule model expressed as Hexadecimal number. Hex representation has an 'X' as prefix.
ModuleTypeOCTET STRING (SIZE(7))currentModule type expressed as Hexadecimal number. Hex representation has an 'X' as prefix.
SerialNumberOCTET STRING (SIZE (0..10))currentSerial number
SpvAlarmIndexesInteger32 (1..256)currentmodules alarms indexes.
SpvAlarmNameOCTET STRING(SIZE(0..20))currentName of external alarms
SpvAlarmPolarityINTEGER { activeLow(0), activeHigh(1), undetermined(2) }currentalarm polarity (active low/high) or undetermined for internal alarm
SpvAlarmSeverityINTEGER { undetermined(0), critical(1), major(2), minor(3), warning(4), cleared(5) }currentAlarm severity.
SpvAlarmStateINTEGER { ceased(0), active(1), undetermined(2) }currentAlarm state
SpvApnStateValuesINTEGER { notActive(0), active(1) }currentAPN status.
SpvBooleanTypeINTEGER { false(0), true(1) }currentBasic boolean value.
SpvDasTraySelectorUlTINTEGER { diversity(0), main(1) }currentSelects power measure in Das Tray UL Channels
SpvDataSourceINTEGER { dataReadFromDevice(0), dataReadFromInventory(1) }currentData read from device or inventory.
SpvDfeBandTypeTINTEGER { wide(0), narrow(1) }currentDFE Band Mode.
SpvDfeFpgaChannelConfigTypeINTEGER { wideNarrow(0), wideMediumNarrow(1), mediumMediumMediumNarrow(2), mediumMediumNarrow(3), mediumNarrow(4), narrow(5) }currentList of all channels configurations for DFE-FPGA.
SpvDfeFpgaPwrSwitchValuesINTEGER { peak(0), rms(1) }currentFPGA switch states
SpvDiscoveryStateTypeINTEGER { discoveryDone(0), discoveryStartFullSearch(1), discoveryStartIncrementalSearch(2), discoveryRequestTree(3), discoveryTreeFoundFull(4), discoverySendingAccept(5), discoverySendingReject(6), discoveryError(7), discoveryTreeFoundIncr(8) }currentVariable used to set discovery command and read discovery esit.
SpvFirewallTINTEGER { disabled(0), enabled(1) }currenttunnel insecure or encrypted
SpvFloatingPointValueOCTET STRINGcurrentstring representing floating point values
SpvFtpModeTINTEGER { none(0), ftps(1) }currentFTP Mode
SpvHttpModeTINTEGER { none(0), http(1), https(2), httpAndhttps(3) }currenthttp/https
SpvInventoryStateTypeINTEGER { inventoryMissing(-1), inventoryDone(0), inventoryInProgress(1) }currentVariable used to set inventory command and read status.
SpvLpPoiMbPwrLimitModeTINTEGER { rfOff(0), minus10dBPlus(1) }currentpower limiter mode
SpvLpPoiMbWtTddBandFilterTypeINTEGER { from3400to3600(0), from3700to3980(1), bypass(2) }currentBand filter
SpvLpPoiMbWtTddConfigScsIndexTypeINTEGER { value15(0), value30(1), value60(2) }currentSubcarrier spacing (kHz)
SpvLpPoiMbWtTddPeriodPatternTypeINTEGER { value0dot5(0), value0dot625(1), value1(2), value1dot25(3), value2(4), value2dot5(5), value3(6), value4(7), value5(8), value10(9) }currentDL/UL Pattern duration (ms)
SpvLpPoiMbWtTddSearchStartLevelTypeINTEGER { valueMinus50(-50), valueMinus45(-45), valueMinus40(-40), valueMinus30(-30) }currentSearch start level (dBm)
SpvLpPoiMbWtTddSsPositionTypeINTEGER { value0(0), value2(1), value4(2), value8(3), value16(4), value20(5), value22(6), value30(7), value32(8), value36(9), value44(10), value48(11), value50(12) }currentSSB position
SpvLpPoiMbWtTsyncActiveSelectorTypeINTEGER { main(0), secondary(1), auto(2), external(4) }currentTsync active selector
SpvLpPoiMbWtTsyncRfConfTypeINTEGER { port1(0), port2(1), port3(2), port4(3) }currentTsync RF conf
SpvModemCommStateTINTEGER { undetermined(0), critical(1), major(2), minor(3), warning(4), cleared(5), reset(10) }currentModem comm state.
SpvModemModesINTEGER { mux(0), onlySMS(1), onlyGPRS(2) }currentmodem modality
SpvModemTypeTINTEGER { undefined(-1), none(0), gsm(1), umts(2), cdma(3), edu(4) }currentmodem type
SpvModemUserCmdStateTINTEGER { start(0), inProgress(1), resultAvailable(2) }currentModem User command state
SpvModuleReachabilityINTEGER { notReachable(0), reachable(1) }currentIndicates weather a module is reachable.
SpvMuSpvModeINTEGER { primary(0), secondary(1), auto(2) }currentMode
SpvNgOtrxConnectorSfpTINTEGER { absent(0), lcFiber(1), coaxial(2), unknown(3), error(255) }currentRF Port Mapping for NG Otrx
SpvPoiOranV2SectorPortControlTypeINTEGER { ports1to8(0), ports1to6(1), ports1to4(2), ports1to2(3) }currentSector Port Control
SpvPoiOranV2SfpBitrateTypeINTEGER { gbps25(0), gbps10(1) }currentBitrate
SpvRelayNcINTEGER { unused(0), normallyOpen(1), normallyClosed(2) }currentNormal state of the relay in case of automatical manage.
SpvRelayPolicyIntrainINTEGER { manual(0), autoAllCritical(1), autoAllCriticalMajor(2), autoAllCriticalMajorMinor(3), autoAllCriticalMajorMinorWarning(4), autoSpvCritical(5), autoSpvCriticalMajor(6), autoSpvCriticalMajorMinor(7), autoSpvCriticalMajorMinorWarning(8), autoBdaMainCritical(9), autoBdaMainCriticalMajor(10), autoBdaMainCriticalMajorMinor(11), autoBdaMainCriticalMajorMinorWarning(12), autoBdaAdd1Critical(13), autoBdaAdd1CriticalMajor(14), autoBdaAdd1CriticalMajorMinor(15), autoBdaAdd1CriticalMajorMinorWarning(16), autoBdaAdd2Critical(17), autoBdaAdd2CriticalMajor(18), autoBdaAdd2CriticalMajorMinor(19), autoBdaAdd2CriticalMajorMinorWarning(20), autoBdaAdd3Critical(21), autoBdaAdd3CriticalMajor(22), autoBdaAdd3CriticalMajorMinor(23), autoBdaAdd3CriticalMajorMinorWarning(24) }currentRelay policy.
SpvRelayPolicyMuINTEGER { manualOn(0), autoCritical(1), autoMajorCritical(2), autoMinorMajorCritical(3), autoWarningMinorMajorCritical(4), autoMUCritical(5), autoMUMajorCritical(6), autoMUMinorMajorCritical(7), autoMUWarningMinorMajorCritical(8), autoRUCritical(9), autoRUMajorCritical(10), autoRUMinorMajorCritical(11), autoRUWarningMinorMajorCritical(12) }currentRelay status.
SpvRelayStateINTEGER { open(0), closed(1) }currentRelay status.
SpvRotrxChannelInteger32 (1..6)currentROTRX channels (1-2-3-4-5-6)
SpvRuFansNumberTypeINTEGER { fansNumber3(0), fansNumber2(1) }currentnumber of fun in remote unit
SpvShellModeTINTEGER { none(0), ssh(1) }currentwhich shell to use to access board
SpvSmsFormatTINTEGER { classic(0), human(1) }currentBasic boolean value.
SpvSnmpModeTINTEGER { snmpv1(1), snmpv3(2) }currentsnmp v1 or snmp v3
SpvSnmpTrapModeTINTEGER { none(0), snmptrapv2(1), snmpvtrap3(2) }currentsnmp v1 or snmp v3
SpvSynchModeTINTEGER { none(0), ntp(2) }currentHow to synchronize clock of the board with external server
SpvTunnelModeTINTEGER { none(0), tunnelNoSsl(1), tunnelSsl(2) }currenttunnel insecure or encrypted
SpvUnitSystemTypeINTEGER { metric(0), angloSaxon(1) }currentAlarm severity.
SpvUpgradeActionTypeTINTEGER { stateNoOp(0), executeDownloadToBoard(1), stateDownloadingToBoard(2), stateDownloadToBoardFailed(3), stateUpgrading(4), stateUpgradeCompleted(5), stateUpgradeFailed(6), executePrepareConfigFile(7), statePreparingConfigFile(8), statePrepareConfigFileCompleted(9), statePrepareConfigFileFailed(10), executeRestoreConfigFile(11), stateUploadingConfigFile(12), stateRestoringFromConfigFile(13), stateUploadConfigFileFailed(14), stateRestoreFromConfigFileCompleted(15), stateRestoreFromConfigFileFailed(16) }currentbackup/restore commands list/states
SpvVpnDeviceINTEGER { tap(0), tun(1) }currentopenvpn device tap/tun