MIB Viewer

JUNIPER-POWER-SUPPLY-UNIT-MIB

42 objects
The Juniper Supply Unit MIB definitions for enabling power monitoring and management of a juniper device.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2636.3.58.1IdentityjnxPsuMIBThe Juniper Supply Unit MIB definitions for enabling power monitoring and management of a juniper device.
1.3.6.1.4.1.2636.3.58.1.1NodejnxPsuNotifications
1.3.6.1.4.1.2636.3.58.1.2NodejnxPsuObjects
1.3.6.1.4.1.2636.3.58.1.2.1NodejnxPsuScalars
1.3.6.1.4.1.2636.3.58.1.2.1.1ScalarjnxPsuAvailableDeviceCountread-onlycurrentGives the number of PSU units available online in the System.
1.3.6.1.4.1.2636.3.58.1.2.1.2ScalarjnxPsuAvailableAveragePowerSupplyread-onlycurrentGives the total average power that the System can supply from the available online units in Watts.
1.3.6.1.4.1.2636.3.58.1.2.1.3ScalarjnxPsuAvailableMaxPowerSupplyread-onlycurrentGives the total maximum power that the System can supply from the available online units in Watts.
1.3.6.1.4.1.2636.3.58.1.2.1.4ScalarjnxPsuRedundancyread-onlycurrentPSU power redundancy configuration.
1.3.6.1.4.1.2636.3.58.1.2.1.5ScalarjnxPsuChassisPowerReservedread-onlycurrentPower reserved for Chassis in Watts.
1.3.6.1.4.1.2636.3.58.1.2.1.6ScalarjnxPsuChassisPowerAllocatedread-onlycurrentTotal power allocated for chassis and all the FPCs in Watts.
1.3.6.1.4.1.2636.3.58.1.2.1.7ScalarjnxPsuRedundantPowerAvailableread-onlycurrentPower(in Watts) that is still available for allocation even while supporting redundancy with the present usage.
1.3.6.1.4.1.2636.3.58.1.2.1.8ScalarjnxPsuTotalPowerAvailableread-onlycurrentPower(in Watts) which could be made available for further allocation without supporting any redundancy with the present usage.
1.3.6.1.4.1.2636.3.58.1.2.1.9ScalarjnxPsuChassisPowerConsumedread-onlycurrentTotal power consumed by the entire system rounded to the nearest integer. This is calculated using the PowerFactor, Current and Voltage values of each PSU that…
1.3.6.1.4.1.2636.3.58.1.2.1.10ScalarjnxPsuTemperatureInflowread-onlycurrentAverage inflow temperature calculated from all the available input sensors on the master RE.
1.3.6.1.4.1.2636.3.58.1.2.1.11ScalarjnxPsuTemperatureOutflowread-onlycurrentAverage outflow temperature calculated from all the available output sensors on the master RE.
1.3.6.1.4.1.2636.3.58.1.2.1.12ScalarjnxPsuTemperatureInflowSamplesread-onlycurrentThe number of samples being taken while calculating jnxPsuTemperatureInflow.
1.3.6.1.4.1.2636.3.58.1.2.1.13ScalarjnxPsuTemperatureOutflowSamplesread-onlycurrentThe number of samples being taken while calculating jnxPsuTemperatureOutflow.
1.3.6.1.4.1.2636.3.58.1.2.2TablejnxPsuTablenot-accessiblecurrentA list of power entries for each PSU component.
1.3.6.1.4.1.2636.3.58.1.2.2.1RowjnxPsuEntrynot-accessiblecurrentDefines an entry in jnxPsuTable.
1.3.6.1.4.1.2636.3.58.1.2.2.1.1ColumnjnxPsuAvgPowerread-onlycurrentBuffer that contains the average power used, in Watts for each component.
1.3.6.1.4.1.2636.3.58.1.2.2.1.2ColumnjnxPsuMaxPowerread-onlycurrentBuffer that contains the max power available, in Watts for each component.
1.3.6.1.4.1.2636.3.58.1.2.2.1.3ColumnjnxPsuModeread-onlycurrentMode for each PSU component.
1.3.6.1.4.1.2636.3.58.1.2.2.1.4ColumnjnxPsuOutletCountread-onlycurrentThe number of outlets (regardless of their current state) present on this psu component, default is 0.
1.3.6.1.4.1.2636.3.58.1.2.3TablejnxPsuEnvironmentTablenot-accessiblecurrentA list of PSU Environment entries.
1.3.6.1.4.1.2636.3.58.1.2.3.1RowjnxPsuEnvironmentEntrynot-accessiblecurrentDefines an entry in jnxPsuEnvironmentTable.
1.3.6.1.4.1.2636.3.58.1.2.3.1.1ColumnjnxPsuThermalValueread-onlycurrentTemparature at each component in degrees Celsius rounded to the nearest integer.
1.3.6.1.4.1.2636.3.58.1.2.3.1.2ColumnjnxPsuHumidityValueread-onlycurrentHumidity at each component in percentage.
1.3.6.1.4.1.2636.3.58.1.2.4TablejnxPsuOutletTablenot-accessiblecurrentGives details of each Power outlet`s state, capacity to supply power, and other details.
1.3.6.1.4.1.2636.3.58.1.2.4.1RowjnxPsuOutletEntrynot-accessiblecurrentA value contained within the OutletEntry
1.3.6.1.4.1.2636.3.58.1.2.4.1.1ColumnjnxPsuOutletNameread-onlycurrentOutlet name associated to the power supply unit for each PSU Component.
1.3.6.1.4.1.2636.3.58.1.2.4.1.2ColumnjnxPsuOutletDescriptionread-onlycurrentOutlet description associated to the power supply unit for each PSU Component.
1.3.6.1.4.1.2636.3.58.1.2.4.1.3ColumnjnxPsuOutletAvgPowerread-onlycurrentBuffer that contains the average power used, in Watts for each component.
1.3.6.1.4.1.2636.3.58.1.2.4.1.4ColumnjnxPsuOutletMaxPowerread-onlycurrentBuffer that contains the maximum power available, in Watts for each component.
1.3.6.1.4.1.2636.3.58.1.2.4.1.5ColumnjnxPsuOutletCurrentread-onlycurrentPSU output current in milliamps rounded to the nearest integer.
1.3.6.1.4.1.2636.3.58.1.2.4.1.8ColumnjnxPsuOutletStatusread-onlycurrentThe value of the operational status for the given outlet. This can also be used to set the outlet state
1.3.6.1.4.1.2636.3.58.1.2.4.1.9ColumnjnxPsuOutletVoltageread-onlycurrentOutput voltage in Volts rounded to the nearest integer.
1.3.6.1.4.1.2636.3.58.1.2.4.1.10ColumnjnxPsuOutletPowerFactorValueread-onlycurrentPower factor percentage of each PSU (2k/3k). Algorithm for calculation of Power Factor is below. For PowerOut values that fall in between 618.93W and 915.24W, …
1.3.6.1.4.1.2636.3.58.1.2.4.1.11ColumnjnxPsuOutletPowerConsumedread-onlycurrentPower Consumed by each outlet units in Watts.
1.3.6.1.4.1.2636.3.58.1.2.5TablejnxPsuFpcPowerTablenot-accessiblecurrentA list of entries for each FPC(Flexible PIC Concentrator) giving it's assigned priority and power being allocated. More information on FPCs can be found in JUN…
1.3.6.1.4.1.2636.3.58.1.2.5.1RowjnxPsuFpcPowerEntrynot-accessiblecurrentA value contained within the FpcPowerEntry
1.3.6.1.4.1.2636.3.58.1.2.5.1.1ColumnjnxPsuFpcPowerPriorityread-onlycurrentThe Power budget priority assigned to the FPC. Lower number means higher priority.
1.3.6.1.4.1.2636.3.58.1.2.5.1.2ColumnjnxPsuFpcPowerAllocatedread-onlycurrentThe Power allocated to the FPC in Watts.