JUNIPER-RPM-MIB
49 objects
This mib provides data associated with the Realtime Performance Monitoring feature.
Imported Objects
| DISMAN-PING-MIB | pingCtlOwnerIndex pingCtlTestName pingProbeHistoryIndex |
| HCNUM-TC | CounterBasedGauge64 |
| JUNIPER-SMI | jnxRpmMibRoot |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | -- RFC2578 DateAndTime TEXTUAL-CONVENTION |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2636.3.50.1 | IdentityjnxRpmMib | This mib provides data associated with the Realtime Performance Monitoring feature. | ||
| 1.3.6.1.4.1.2636.3.50.1.1 | TablejnxRpmResultsSampleTable | not-accessible | current | This table provides measurements from the latest individual RPM probe samples. Within each sample, the specific measurement type is identified by jnxRpmResSamp… |
| 1.3.6.1.4.1.2636.3.50.1.1.1 | RowjnxRpmResultsSampleEntry | not-accessible | current | Each entry provides a specific measurement type for a single probe. |
| 1.3.6.1.4.1.2636.3.50.1.1.1.1 | ColumnjnxRpmResSampleType | not-accessible | current | This object identifies the specific measurement type returned by jnxRpmResSampleValue. |
| 1.3.6.1.4.1.2636.3.50.1.1.1.2 | ColumnjnxRpmResSampleValue | read-only | current | This object returns the measurement identified by the corresponding jnxRpmResSampleType. |
| 1.3.6.1.4.1.2636.3.50.1.1.1.3 | ColumnjnxRpmResSampleTsType | read-only | current | This object identifies the type of timestamp used to obtain this measurement. |
| 1.3.6.1.4.1.2636.3.50.1.1.1.4 | ColumnjnxRpmResSampleDate | read-only | current | This object provides the date and time of when this measurement was obtained. |
| 1.3.6.1.4.1.2636.3.50.1.2 | TablejnxRpmResultsSummaryTable | not-accessible | current | This table provides a summary of the results for a specific RPM entry (identified by pingCtlOwnerIndex/pingCtlTestName). The scope of the summary is identified… |
| 1.3.6.1.4.1.2636.3.50.1.2.1 | RowjnxRpmResultsSummaryEntry | not-accessible | current | Each entry in the table provides a summary of the RPM results over a single collection of probes. For each RPM entry, there are several collections maintained:… |
| 1.3.6.1.4.1.2636.3.50.1.2.1.1 | ColumnjnxRpmResSumCollection | not-accessible | current | This object identifes the collection of probes over which the summary data represented by the other objects in this table applies. Note, if a collection type i… |
| 1.3.6.1.4.1.2636.3.50.1.2.1.2 | ColumnjnxRpmResSumSent | read-only | current | This object provides the number of probes sent within the collection identified by jnxRpmResSumCollection. |
| 1.3.6.1.4.1.2636.3.50.1.2.1.3 | ColumnjnxRpmResSumReceived | read-only | current | This object provides the number of probes received within the collection identified by jnxRpmResSumCollection. |
| 1.3.6.1.4.1.2636.3.50.1.2.1.4 | ColumnjnxRpmResSumPercentLost | read-only | current | This object provides the percentage of probes lost within the collection identified by jnxRpmResSumCollection. |
| 1.3.6.1.4.1.2636.3.50.1.2.1.5 | ColumnjnxRpmResSumDate | read-only | current | This object provides the date and time of when the most recent probe within the collection identified by jnxRpmResSumCollection was completed. |
| 1.3.6.1.4.1.2636.3.50.1.3 | TablejnxRpmResultsCalculatedTable | not-accessible | current | This table provides a set of calculated values for each RPM entry, for each collection of probes maintained within that entry, and for each supported measureme… |
| 1.3.6.1.4.1.2636.3.50.1.3.1 | RowjnxRpmResultsCalculatedEntry | not-accessible | current | |
| 1.3.6.1.4.1.2636.3.50.1.3.1.1 | ColumnjnxRpmResCalcSet | not-accessible | current | This object identifies the measurement set upon which the calculations returned by the other objects in this table are based. |
| 1.3.6.1.4.1.2636.3.50.1.3.1.2 | ColumnjnxRpmResCalcSamples | read-only | current | The number of samples used in this calculations. |
| 1.3.6.1.4.1.2636.3.50.1.3.1.3 | ColumnjnxRpmResCalcMin | read-only | current | The minimum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds. |
| 1.3.6.1.4.1.2636.3.50.1.3.1.4 | ColumnjnxRpmResCalcMax | read-only | current | The maximum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds. |
| 1.3.6.1.4.1.2636.3.50.1.3.1.5 | ColumnjnxRpmResCalcAverage | read-only | current | The average of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds. |
| 1.3.6.1.4.1.2636.3.50.1.3.1.6 | ColumnjnxRpmResCalcPkToPk | read-only | current | The difference between the minimum and maximum of all the samples in the collection and measurement set associated with this row. Values are provided in units … |
| 1.3.6.1.4.1.2636.3.50.1.3.1.7 | ColumnjnxRpmResCalcStdDev | read-only | current | The standard deviation calculated over all the samples in the collection and measurement set associated with this row. Values are provided in units of microsec… |
| 1.3.6.1.4.1.2636.3.50.1.3.1.8 | ColumnjnxRpmResCalcSum | read-only | current | The sum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds. |
| 1.3.6.1.4.1.2636.3.50.1.4 | TablejnxRpmHistorySampleTable | not-accessible | current | This table provides measurements for individual RPM probe samples. In addition to the last completed sample, a configurable number of the most recent samples a… |
| 1.3.6.1.4.1.2636.3.50.1.4.1 | RowjnxRpmHistorySampleEntry | not-accessible | current | |
| 1.3.6.1.4.1.2636.3.50.1.4.1.1 | ColumnjnxRpmHistSampleType | not-accessible | current | This object identifies the specific measurement type returned by jnxRpmHistSampleValue. |
| 1.3.6.1.4.1.2636.3.50.1.4.1.2 | ColumnjnxRpmHistSampleValue | read-only | current | This object returns the measurement identified by the corresponding jnxRpmHistSampleType. |
| 1.3.6.1.4.1.2636.3.50.1.4.1.3 | ColumnjnxRpmHistSampleTsType | read-only | current | This object identifies the type of timestamp used to obtain this measurement. |
| 1.3.6.1.4.1.2636.3.50.1.5 | TablejnxRpmHistorySummaryTable | not-accessible | current | This table provides historical summary data for each collection of probes within each RPM Entry, similar to the jnxRpmResultsSummaryTable. In addition to the c… |
| 1.3.6.1.4.1.2636.3.50.1.5.1 | RowjnxRpmHistorySummaryEntry | not-accessible | current | |
| 1.3.6.1.4.1.2636.3.50.1.5.1.1 | ColumnjnxRpmHistSumCollection | not-accessible | current | Identifies the collection of probes whose results are summarized by this row. At this time, historical summaries are available only for the current test (curre… |
| 1.3.6.1.4.1.2636.3.50.1.5.1.2 | ColumnjnxRpmHistSumSent | read-only | current | This object provides the number of probes sent within the collection identified by jnxRpmHistSumCollection. |
| 1.3.6.1.4.1.2636.3.50.1.5.1.3 | ColumnjnxRpmHistSumReceived | read-only | current | This object provides the number of probes received within the collection identified by jnxRpmHistSumCollection. |
| 1.3.6.1.4.1.2636.3.50.1.5.1.4 | ColumnjnxRpmHistSumPercentLost | read-only | current | This object provides the percentage of probes lost within the collection identified by jnxRpmHistSumCollection. |
| 1.3.6.1.4.1.2636.3.50.1.6 | TablejnxRpmHistoryCalculatedTable | not-accessible | current | This table provides a set of calculated values for each RPM entry, for each collection of probes maintained within that entry, and for each supported calculate… |
| 1.3.6.1.4.1.2636.3.50.1.6.1 | RowjnxRpmHistoryCalculatedEntry | not-accessible | current | |
| 1.3.6.1.4.1.2636.3.50.1.6.1.1 | ColumnjnxRpmHistCalcSet | not-accessible | current | This object identifies the measurement set upon which the calculations returned by the other objects in this table are based. |
| 1.3.6.1.4.1.2636.3.50.1.6.1.2 | ColumnjnxRpmHistCalcSamples | read-only | current | The number of samples used in this calculations. |
| 1.3.6.1.4.1.2636.3.50.1.6.1.3 | ColumnjnxRpmHistCalcMin | read-only | current | The minimum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds. |
| 1.3.6.1.4.1.2636.3.50.1.6.1.4 | ColumnjnxRpmHistCalcMax | read-only | current | The maximum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds. |
| 1.3.6.1.4.1.2636.3.50.1.6.1.5 | ColumnjnxRpmHistCalcAverage | read-only | current | The average of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds. |
| 1.3.6.1.4.1.2636.3.50.1.6.1.6 | ColumnjnxRpmHistCalcPkToPk | read-only | current | The difference between the minimum and maximum of all the samples in the collection and measurement set associated with this row. Values are provided in units … |
| 1.3.6.1.4.1.2636.3.50.1.6.1.7 | ColumnjnxRpmHistCalcStdDev | read-only | current | The standard deviation calculated over all the samples in the collection and measurement set associated with this row. Values are provided in units of microsec… |
| 1.3.6.1.4.1.2636.3.50.1.6.1.8 | ColumnjnxRpmHistCalcSum | read-only | current | The sum of all the samples in the collection and measurement set associated with this row. Values are provided in units of microseconds. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| JnxRpmCollectionType | INTEGER { currentTest (1), lastCompletedTest (2), movingAverage (3), allTests (4) } | current | Each RPM entry can maintain several collections of probes and provide separate calculations over each collection. The types of collections include: currentTest lastCompletedTest movingAverage allTests reset). Objects wi… |
| JnxRpmMeasurementSet | INTEGER { roundTripTime (1), posRttJitter (2), negRttJitter (3), egress (4), posEgressJitter (5), negEgressJitter (6), ingress (7), posIngressJitter (8), negIngressJitter (9) } | current | Over each collection of probes, RPM calculates statistics for several sets of measurements. These sets include the following: roundTripTime posRttJitter measurements negRttJitter measurements egress one-way delays posEg… |
| JnxRpmMeasurementType | INTEGER { roundTripTime (1), rttJitter (2), rttInterarrivalJitter (3), egress (4), egressJitter (5), egressInterarrivalJitter (6), ingress (7), ingressJitter (8), ingressInterarrivalJitter (9) } | current | For each individual probe, several different measurements can be made. These include the following (all measurements are provided in units of microseconds): roundTripTime a probe and the arrival of its response. rttJitt… |
| JnxRpmTimestampType | INTEGER { software (1), clientHardware (2), clientAndServerHardware (3) } | current | This object identifies the type of timestamp used to obtain a measurement: software this indicates software based timestamps are used on both client and server. clientHardware this indicates hardware based timestamps ar… |